Subpart R: Standard Overview 1926.750

Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Embed Size (px)

Citation preview

Page 1: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Subpart R: Standard Overview1926.750

Page 2: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Key Provisions Of The Revised Subpart R Standard

• Requires fall protection at 15 feet– Exception: Connecting and Decking Zone

• Includes a Multiple Lift Rigging Procedure for up to five structural members

• Requires that shear connectors be installed after the structural member is erected

• Requires that decking holes and openings not be cut until essential to the construction process

• Requires a minimum of four anchor rods (anchor bolts) on all columns

Page 3: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Key Provisions Of The Revised Subpart Standard

(cont)• Requires controlling contractors to notify steel

erectors of repairs or modifications to anchor rods (anchor bolts)

• Addresses “double connections,” installation of steel joists, and landing of loads to avoid collapses during steel erection

• Addresses slippery surfaces on beams and decking

• Contains a separate section on Systems Engineered Buildings

Page 4: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Phase-In of Certain Requirements

• Building Construction:

– Building Permit obtained prior to January 18, 2001

– Where Steel Erection began on or before September 16, 2001

• Bridge Construction:

– Bridge Project has a contract date before January 18, 2001

– Steel Erection began before September 16, 2001

Page 5: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Key Provisions Of The Revised Subpart R Standard

• Requires controlling contractors to provide adequate site access and adequate storage space to the steel erector

• Requires a stabilizer plate on columns for tie joist (TJ) and joist girders to provide an attachment point for guying or plumbing up of cables

• Provides guidelines for a non-mandatory site specific erection plan

Page 6: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Key Provisions Of The Revised Subpart R Standard

• Requires fall protection training for all employees exposed to fall hazards

• Allows a Controlled Decking Zone for decking installations at heights of 15-30 feet

• Requires controlling contractor to provide overhead protection or not allow construction underneath steel erection activities

Page 7: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Subpart R - Final Rule

• The Steel Erection Rule was published on January 18, 2001.

• Effective date January 18, 2002

Page 8: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.750

Scope:• This subpart sets forth requirements to protect

employees from the hazards associated with steel erection activities involved in:– Construction, alteration, and/or repair of

single and multi-story buildings, bridges, and other structures where steel erection occurs.

Page 9: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Single story building

Page 10: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Multi-story building

Page 11: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Bridge construction

Page 12: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.750Scope and Application (cont)

• Application:– Hoisting– Connecting– Welding– Guying/Bracing– Bolting– Plumbing/Rigging

– Steel joists and metal buildings

– Installing metal deck, curtain walls, window walls, siding systems

– Miscellaneous metals

– Ornamental iron– Similar metals– Moving point to

point

Page 13: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Scope (cont.)

Does not include:• Electrical transmission

towers,

• communication and broadcast towers,

• Tanks

Ironworker using rope grabs tomake tower connection.

Page 14: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Duties of Controlling Contractor under this

subpart• Written notification to the steel erector:

– Concrete in piers/walls is cured re ASTM spec– Modifications/repairs to anchor bolts approved

by project engineer (.752(a); .755(b))• Adequate on-site access roads (.752(c)) • Preclude work below steel erection unless there is

overhead protection (.759(b))• Choose whether to accept responsibility for

maintaining fall protection equipment left by steel erector (otherwise must be removed) (.760(e))

Page 15: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.752 Site Layout, Erection Plan and Construction

Sequence• Approval to begin steel erection:

– Curing of concrete 752(a)– Repairs/modifications to anchor bolts 755(b)

• Site layout– Adequate roads into and through the site 752(c)(1)– Adequate space for the safe storage of materials

752(c)(2)• Pre-plan hoisting operations 753(d)• Modifications made to site-specific plan if equivalent

protection is provided.Safety latches on hooks activated 753(c)(5)Landing decking on steel joists (.757(e)(4))

Page 16: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.750 (c) Specific Controlling Contractor Duties

• Written notification to the steel erector:– Concrete in piers/walls is cured re: ASTM spec– Anchor belt modifications/repairs approved by

project engineer (.752(a) and .755(b)

Page 17: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.750(c) Specific Controlling Contractor Duties

• Adequate on-site access roads [.752(c)]

Before and after photos

Page 18: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.750(c) Specific Controlling Contractor Duties

• Preclude work below steel erection unless there is overhead protection [.759(b)]

• Choose whether to accept responsibility for maintaining fall protection equipment left by erector (otherwise it must be removed) [.760(e)]

Page 19: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Competent Person• Means one who is capable of identifying

existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them.

Page 20: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Connector• An employee who, working with

hoisting equipment, is placing and connecting structural members and/or components.

Page 21: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Controlling Contractor• Means a prime contractor, general

contractor, construction manager or any other legal entity which has the overall responsibility for the construction of the project -- its planning, quality and completion.

Page 22: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Qualified person• One who, by possession of a

recognized degree, certificate, or professional standing, or who by extensive knowledge, training, and experience, has successfully demonstrated the ability to solve or resolve problems relating to the subject matter, the work, or the project.

Page 23: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Shear Connector• Headed steel studs, steel bars, steel

lugs, and similar devices which are attached to a structural member for the purpose of achieving composite action with concrete.

Page 24: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Site-Specific Erection Plan

• Requires pre-planning of key erection elements, including coordination with controlling contractor before erection begins, in certain circumstances.

Page 25: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Steel Erection

• Construction, alteration or repair of steel buildings, bridges and other structures, including the installation of metal decking and all planking used during the process of erection.

Page 26: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.752 Site Layout, Erection Plan and Construction Sequence

• Certification of:– Proper curing of

concrete in footings, piers, etc. for steel columns

– Anchor bolt repairs, modifications

• Pre-plan hoisting operations

Page 27: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.753 Hoisting and Rigging

• Provisions of 1926.550 apply to hoisting and rigging (except 1926.550(g)(2) (note: OSHA adopted 1994 ANSI B-30.5 for subpart R only)

• Pre-shift visual inspections of cranes 753(c)• Working under loads 753(d)• Multiple lift rigging procedures 753(e)

– Maximum of five members hoisted– Only beams and similar structural members

lifted– Employees trained in accordance with 761(c)(1)– No lift if contrary to manufacturer’s

specifications and limitations

Page 28: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Multiple lift rigging (cont)

– Rigging must be specifically designed with a 5 to 1 safety factor

– Multiple lift rigging assembly must be rigged with members at their center of gravity and maintained reasonably level

– Rigged from top to bottom and rigged at least 7 feet apart

– Members must be set from the bottom up

Page 29: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.754 Structural Steel Assembly

• Provides specific work practices for:– Maintaining structural stability 754(b)– Landing deck bundles 757(e)(4)– Minimizing fall hazards in interior openings 754(b)(3)

• Walking/working surface requirements:– Tripping hazards: shear connectors (and similar

projections) generally prohibited until decking is down 754(c)(1)(ii)

– Slip resistance: criteria for painted structural steel members (effective 5 years after the rest of standard) 754(c)(3)

Page 30: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Structural Steel (cont)

• Roof and floor holes and openings:– Framed metal deck openings must have

structural members turned down to allow for continuous deck installation

– Elevator shafts, stair wells, etc., must be decked over or employees must be protected in accordance with 760(a)(1)

– Metal decking holes and openings must not be cut until immediately prior to being permanently filled

– Gaps around columns must be covered

Page 31: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Structural Steel (cont)

• Metal decking:– Metal decking must be laid tightly and

secured immediately upon placement except as provided in 760(c)

– Derrick floor must be decked and/or planked and the steel member connections completed to support the intended load

– Loads placed on the derrick floor must be distributed over the underlying support members to prevent local overloading

Page 32: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.754 Structural Steel Assembly

Covers for floor or roof openings shall be secured and marked with the word HOLE or COVER

Cover marked and secured

No securement or marking to indicate the opening.

Page 33: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Derrick Floor Diagram

Page 34: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.755 Column Anchorage

• Minimum of 4 anchor rods (anchor bolts)• Set on level finished floor, pre-grouted leveling

plates, leveling nuts, or shim packs• Competent person will determine whether

guying or bracing is needed• Engineer of record will approve all

repairs/replacements or modifications of anchor rods (anchor bolts)

Page 35: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.755 Column Anchorage

Column would not align with the j-boltsso the steel erector

cut holes and weldedtabs to hold column.

Page 36: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.756 Beams and Columns

• Two bolts per connection prior to releasing hoisting line (competent person will determine if more than two are needed)

• Diagonal bracing (solid web) will be secured by at least one bolt per connection

• Safe procedures/devices for making double connections at columns

• Requirements to facilitate quick installation of perimeter safety cables:– Column attachments or holes in columns for

perimeter safety cables– Column splice height and strength specified

Page 37: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.756 Beams and Columns

One bolt is installed wrench tight.Two will be installed. The spud wrench holds the beam until theother connector can make his initial connection.

Page 38: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.756 Beams and Columns

• Requires one bolt to remain connected for double connections unless seat or equivalent used

• Seats for double connections shall be designed for the load during the double connection process

Page 39: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.757 Open Web Steel Joists

• Addresses proper joist end attachment, erection procedures– General requirements for the erection of

steel joists– Stabilization of joists (vertical stabilizer plate)– Holes in joists/bolting required for joists in

40’+ bays• Requirements for landing and placing loads on

joists• Some requirements may be modified through a

site-specific erection plan

Page 40: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.757 Open Web Steel Joists

• Hoisting cables not be released until field bolted.

• A vertical stabilizer plate required for each column for steel joists.

Workers making initial connectionfrom two arial lifts.

Page 41: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.758 System-Engineered Metal Buildings

• All requirements of this subpart apply to erection except 755 (column anchorage) and 757 (open web steel joists)

• Minimum of 4 anchor rods (anchor bolts) for structural columns

• Rigid frames will have 50 percent of their bolts or the number of bolts specified by the manufacturer (which ever is greater) installed and tightened before the hoisting equipment is released

Page 42: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

System-Engineered Metal Buildings (cont)

• Loads being placed on structural steel prior to bolting or welding

• Girt and eave strut-to-frame connections• Steel joists/cold-formed joists • Using purlins as walking/working surfaces• Load placement within 8 feet of support

member

Page 43: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.759 Falling Object Protection

• Secure loose items aloft• Controlling contractor to bar other operations

below steel erection unless falling object protection provided

Page 44: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.759 Falling Object Protection (does not apply to materials being hoisted)

Ironworkers have material securedin aerial lift

Page 45: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.760 Fall Protection

• All must be protected at heights greater than 2 stories or 30 feet, including connectors and deckers

• Between 15 and 30 feet: Fall protection required for all with exceptions for:– Deckers in controlled decking zone (CDZ)

and– Connectors

• Connectors must be provided and wear equipment necessary to be able to be tied-off, or be provided with other means of fall protection

Page 46: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.760 Fall Protection (cont.)

• Controlled decking zone:– Max Dimensions 90’ by 90’ – For leading edge decking work

• limited access • designated boundaries by control lines• Work practices for attaching deck:

– install safety attachments from leading edge back

– no final attachments allowed in CDZ– up to 3000 SF of unsecured decking

• specific training requirements

Page 47: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

1926.760 Fall Protection (cont.)

• Perimeter cables required– Must be installed “as soon as the metal

decking has been installed” • Custody of Fall Protection Equipment:

– Controlling contractor must choose to either:• accept responsibility for maintaining fall

protection equipment left by erector,• OR ensure that it is removed (.760(e))

Page 48: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.760 Fall Protection

Ironworker using the

“beemer”system of fall arrest.

Page 49: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.760 Fall Protection (cont.)

• Guardrails and nets used at opening in back

• Note: ladder not long enough

.

Page 50: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

§1926.761 Training

• Qualified person to train workers in use & operation of fall protection equipment

• Qualified person to train workers engaged in specific activities:– “christmas-treeing– connecting– CDZ procedures

Page 51: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

OSHA’s Web Site

• The complete standard can be obtained from our web site at www.osha.gov.

Page 52: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Appendices

• A-Guidelines for site-specific erection plan (NM)

• B-Slip-resistance test methods (NM)• C-Illustrations of bridging terminus points

(NM)• D-Control lines for controlled decking zones

(NM)

Page 53: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Appendices

• E-Training compliance (NM)• F-Perimeter safety cables (NM)• G-Fall protection system criteria (M)• H-Double connection illustrations (NM)

Page 54: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

The End

Page 55: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Adequate roads for safe delivery of cranes

Page 56: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Adequate space for storage of materials

Page 57: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Pre shift visual inspections of cranes

Page 58: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Multiple lift rigging

Page 59: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Multiple lift rigging

Page 60: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Shear connector

Page 61: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Framed metal deck openings

Must be turned down to allowcontinuous deck installationexcept where not allowed by structural design.

Page 62: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Safety deck attachment

Page 63: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

System-Engineered Metal Buildings

Minimum of four anchorrods (anchor bolts)for structural columns

Page 64: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Shim Packs

Page 65: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Field modification of anchor rod

Page 66: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Two bolts per connection

Page 67: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Diagonal bracingSolid web structural membersused as diagonal bracing must be secured by at least one bolt per connection drawn up wrench tight or the equivalentas specified by the project’s structural engineer on record.

Page 68: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Column attachments for safety cable

Page 69: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Column splice

Page 70: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Vertical stabilizer plate

Page 71: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Bolted joists

Page 72: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Systems-Engineered Metal Buildings

Rigid frames will have 50%of their bolts or the number ofbolts specified by the manufacturer (whichever isgreater) installed and tightened before the hoistingequipment is released

Page 73: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Construction load

Page 74: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Girt and eave strut-to-frame connections

Page 75: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Falling object protection

Secure all loose items aloft

Page 76: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Controlled Decking Zone (CDZ)

Page 77: Subpart R: Standard Overview 1926.750 Key Provisions Of The Revised Subpart R Standard Requires fall protection at 15 feet –Exception: Connecting and

Connector