4
SWIMMING POOL PUMP INSTALLATION & OPERATING INSTRUCTIONS WARNING: Read and follow all instructions in this manual and on the equipment. Failure to follow instructions can cause serious injury or death. WARNING: Electrical Hazard. Failure to follow Instructions can result in serious injury. WARNING: Appropriately qualified and licensed personnel should install the pump and carry out the electrical connections. WARNING: All electrical connections must be done by a qualified electrician according to local electrical standards. WARNING: Pump should be wired to the main supply through an approved and correctly rated contactor and GFCI. WARNING: Children and persons with reduced physical, sensory or mental capabilities, or lack of experience should not handle and operate the pump. Fingers and foreign objects should be kept away from the openings and moving parts. WARNING: Motor must be suitably grounded. WARNING: The motor must be connected with other bonded parts using appropriately sized conductor using the bonding lug. WARNING: Power supply voltage required by motor should correspond to that of the network and correctly sized cables should be used to connect the pump motor. WARNING: Disconnect the pump from the main power supply completely before servicing. WARNING: Ensure that the appropriate precautions have been taken to prevent suction entrapment. A minimum of two correctly sized suction points are required for each pump. WARNING: Never run the pump dry! Running the pump dry damages the seals and bearings and can cause leakage and flooding. WARNING: Do not try to open the lid or service the pump while it is in operation. WARNING: Do not use petroleum based lubrication for the plastic and rubber components as they will damage the components and lead to failure.

SWIMMING POOL PUMP - POMONAhaywardimg.pomonapoolproducts.com/technicalbulletin/SWIMPROPUM… · SWIMMING POOL PUMP ... flood, fire, accident, lighting shall not be covered by the

Embed Size (px)

Citation preview

SWIMMING POOL PUMP

INSTALLATION & OPERATING INSTRUCTIONS

WARNING: Read and follow all instructions in this manual and on the equipment. Failure to follow instructions can cause

serious injury or death.

WARNING: Electrical Hazard. Failure to follow Instructions can result in serious injury.

WARNING: Appropriately qualified and licensed personnel should install the pump and carry out the electrical connections.

WARNING: All electrical connections must be done by a qualified electrician according to local electrical standards.

WARNING: Pump should be wired to the main supply through an approved and correctly rated contactor and GFCI.

WARNING: Children and persons with reduced physical, sensory or mental capabilities, or lack of experience should not handle

and operate the pump. Fingers and foreign objects should be kept away from the openings and moving parts.

WARNING: Motor must be suitably grounded.

WARNING: The motor must be connected with other bonded parts using appropriately sized conductor using the bonding lug.

WARNING: Power supply voltage required by motor should correspond to that of the network and correctly sized cables

should be used to connect the pump motor.

WARNING: Disconnect the pump from the main power supply completely before servicing.

WARNING: Ensure that the appropriate precautions have been taken to prevent suction entrapment. A minimum of two

correctly sized suction points are required for each pump.

WARNING: Never run the pump dry! Running the pump dry damages the seals and bearings and can cause leakage and

flooding.

WARNING: Do not try to open the lid or service the pump while it is in operation.

WARNING: Do not use petroleum based lubrication for the plastic and rubber components as they will damage the

components and lead to failure.

WARRANTY

To the original purchasers of this equipment, this product is warranted to be free from defects in materials and workmanship.

The product is warrantied for a period of ONE year from the date of purchase. Seals, baskets and o-rings are warranted for

defects in material and workmanship for a period of 30 days.

Improper installation, use, care, negligence and any damage or defect as a result of freezing, flood, fire, accident, lighting shall

not be covered by the warranty.

The defective product must be returned to the authorized dealer. The cost of returning the product to the dealer and any

consequential costs and damages are not covered by the warranty.

Product Registration

DATE OF INSTALLATION:___________________________________

PURCHASED FROM: __________________________________________________________________________

MODEL: ____________________________________ SERIAL NUMBER:_________________________________

INSTALLATION

Install the pump at the right distance from the base to minimize the distance between the suction point and pump.

Install the pump in a ventilated and dry place. The motor requires air to flow freely around it.

Install the pump so that the external disconnect switch is easily visible and accessible and located close to the pump.

Install a proper ground connection

Fit a 30mA GFCI in the circuit.

Ensure that the power supply voltage matches the voltage on the motor.

Replace all covers before operation.

OPERATION

If the pump is in a flooded suction installation the pump will prime itself when the suction and discharge valves are open.

If the pump is installed above the water level the pump needs to be properly primed prior to start up.

Open the strainer cover and fill strainer housing with water to suction pipe level.

Check the gasket on the cover and replace the strainer cover and secure.

Open all suction and discharge valves as well as air bleed on filter.

Turn on power and allow a reasonable time for priming.

If pump does not start see Troubleshooting Guide.

MAINTENANCE

Clean the strainer basket regularly. Inspect the strainer cover and strainer basket for any damage. Replace as necessary.

The pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.

Keep motor clean. Insure air vents are free from obstruction.

Depending on the operating conditions the seals will need replacement as they wear over time.

Please contact your local agent or dealer for any repair, maintenance and spare parts. Provide the pump and motor details.

TROUBLESHOOTING

A. Motor won’t start

1. Check for improper or loose connections, open switches, relays, blown circuit breakers or fuses.

2. Manually check rotation of motor shaft for free movement and lack of obstruction

B. Motor cuts out – Check for

1. Wiring, loose connections etc.

2. Low voltage at motor ( undersized wiring or improper incoming voltage )

3. Binding and overload.

NOTE: The pump motor is equipped with an automatic thermal overload protection. The motor will automatically shut-off

before heat damage due to an improper operating condition can occur. The motor will start automatically when safe heat level is

reached.

C. Motor hums but does not start

Check the capacitor

D. Pump won’t prime

1. Make sure strainer is filled with water and cover gasket is clean and in place.

2. Make sure that there are no leaks into the suction through loose bolts, connections, o-rings etc.

3. The suction and discharge valves must be open.

4. Block off suction as close to the pump as possible and determine if pump will develop a vacuum.

If vacuum does not develop

Tighten all bolts and fittings on suction side

Check voltage to make sure pump is up to speed

Open pump and check for clogging or obstruction.

Get the shaft seal replaced.

If vacuum develops, check for blocked suction line or strainer, or air leak in suction piping.

E. Low Flow

1. Clogged or restricted strainer or suction line; undersized pool piping.

2. Plugged or restricted discharge line of filter.

3. Air leak in suction ( bubbles issuing from return fitting )

4. Pump operating under speed.

5. Plugged or restricted impeller.

F. Noisy Pump

1. Air leak in suction causing rumbling in pump.

2. Cavitation due to restricted or undersized suction line and unrestricted discharge lines. Correct suction condition if

practical.

3. Vibration due to improper mounting.

4. Foreign matter in pump housing.

5. Bad motor bearings.

NOTE: Only qualified, licensed personnel should install the pump and connect the wiring. Consult your local authorized dealer or

service center if the suggestions in the troubleshooting section do not solve a problem you encounter.

INTERMARK – 2875 Pomona Blvd, Pomona CA 91768 USA

MODEL NO: SWP120551 SWP120751 SWP121051 SWP121551 SWP1205 SWP1207 SWP1210 SWP1215

Power 610 790 920 1110 610 790 920 1110

Voltage Frequency

Phase

230V~ 50Hz

1Phase

230V~ 50Hz

1Phase

230V~ 50Hz

1Phase

230V~ 50Hz

1Phase

120/240V~ 60Hz

1Phase

120/240V~ 60Hz

1Phase

120/240V~ 60Hz

1Phase

120/240V~ 60Hz

1Phase

Amperage 2.6A 3.4A 4.0A 4.8A

Capacitor 18μF,450V 18μF,450V 18μF,450V 30μF,450V 60μF,250V 60μF,250V 60μF,250V 60μF,250V

Switch Size 10A 10A 10A 10A

No Flow Head 14.1M 14.6M 15.7M 16.8M 12.3M 13.0M 13.7M 15.3M

SPARE PARTS

1 SWPX8100LDS SWPX8100LDS SWPX8100LDS SWPX8100LDS SWPX8100LDS SWPX8100LDS SWPX8100LDS SWPX8100LDS

2 SWPX8100S SWPX8100S SWPX8100S SWPX8100S SWPX8100S SWPX8100S SWPX8100S SWPX8100S

3 SWPX8100M SWPX8100M SWPX8100M SWPX8100M SWPX8100M SWPX8100M SWPX8100M SWPX8100M

4 SWPX8100AA SWPX8100AA SWPX8100AA SWPX8100AA SWPX8100AA SWPX8100AA SWPX8100AA SWPX8100AA

5 SWPX1700FG SWPX1700FG SWPX1700FG SWPX1700FG SWPX1700FG SWPX1700FG SWPX1700FG SWPX1700FG

6 SWPGMX600F SWPGMX600F SWPGMX600F SWPGMX600F SWPGMX600F SWPGMX600F SWPGMX600F SWPGMX600F

7 SWPX8100R SWPX8100R SWPX8100R SWPX8100R SWPX8100R SWPX8100R SWPX8100R SWPX8100R

8 SWPX8100B SWPX8100B SWPX8100B SWPX8100B SWPX8100B SWPX8100B SWPX8100B SWPX8100B

9 SWPX8137T SWPX8155T SWPX8175T SWPX81110T SWPX1205T SWPXVL1280T SWPX1210T SWPX1215T

10 SWPX1600Z2 SWPX1600Z2 SWPX1600Z2 SWPX1600Z2 SWPX1600Z2 SWPX1600Z2 SWPX1600Z2 SWPX1600Z2

11 SWPX8100E SWPX8100E SWPX8100E SWPX8100E SWPX8100E SWPX8100E SWPX8100E SWPX8100E

12 SWP6060XZ1 SWP6060XZ1 SWP6060XZ1 SWP6060XZ1 SWP6060XZ1 SWP6060XZ1 SWP6060XZ1 SWP6060XZ1

13 SWPX120551Z1C

SWPX120751Z1C

SWPX121051Z1C

SWPX121551Z1C SWPX1205Z1C SWPX1207Z1C SWPX1210Z1C SWPX1215Z1C

14 SWPX8100Z1 SWPX8100Z1 SWPX8100Z1 SWPX8100Z1 SWPX8100Z1 SWPX8100Z1 SWPX8100Z1 SWPX8100Z1

15 SWPX8100UNSPAK

SWPX8100UNSPAK

SWPX8100UNSPAK

SWPX8100UNSPAK

SWPX8100UNSPAK

SWPX8100UNSPAK

SWPX8100UNSPAK

SWPX8100UNSPAK

16 SWPX8100UNO SWPX8100UNO SWPX8100UNO SWPX8100UNO SWPX8100UNO SWPX8100UNO SWPX8100UNO SWPX8100UNO

1

3

2

4

5

6

11

78

9 10

1213

1415

16

5.2A/2.8A 5.9A/3.1A 6.5A/3.4A 7.7A/4.0A

12A 12A 12A 12A

SPECIFICATIONS AND PARTS LIST