32

Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825
Page 2: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

2

Table of content AIR COOLED CONDENSER

NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

APPLICATIONS AND FEATURES . . . . . . . . . . . . . . . . . 3

SELECTION DATA:SINGLE CIRCUIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

MULTIPLE CIRCUIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

CAPACITY TABLES:CCR,CMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

CVR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

CVR (L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

CNR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

CLW, CNW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

CVW, CVW (L) . . . . . . . . . . . . . . . . . . . . . . . . . . .12

HEAT RECLAIM UNITS:HCD, HMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

CONTROL PANEL NOMENCLATURE . . . . . . . . . . . 13

ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

TYPE OF UNIT

C = CondenserH = Heat Reclaim

TYPE OF MOTOR

C = 1/4 HP - 825 RPMM = 1/2 HP - 1140 RPML = 1 HP - 825 RPMH = 1 1/2 HP - 825 RPMV = 1.5 / 0.95 KW - 780 / 550 RPMN = 2 HP - 1140 RPM

Design Option

D = Direct Drive Motors, Smooth TubesR = Direct Drive Motors, Riffled TubesW = Direct Drive Motors, Wide Fins Spacing (8 fpi), Riffled TubesX = Direct Drive Motors, Coils Mounted V Shape, Riffled Tubes

VOLTAGE

2 = 240/1/603 = 200/3/505 = 208-240/3/606 = 380/3/508 = 600/3/609 = 480/3/60

CAPACITY

NOMINAL CONDENSER CAPACITY(TONS) @25°F T.D. (R-22)

AIR FLOW & SPEED OPTION

H = Horizontal Air FlowL = Low speed

NOMENCLATURE

C V R 0 7 5 H – 9

ELECTRICAL DRAWINGS:STANDARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

VERSATILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

DIMENSIONAL DRAWINGS:VERTICAL AIR FLOW:

CCR, CMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

CLR, CNR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

CVR, CVW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

CLX, CNX (single) . . . . . . . . . . . . . . . . . . . . . . . 20

CLX, CNX (double) . . . . . . . . . . . . . . . . . . . . . . 21

CVX (single) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

CVX (double) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

HORIZONTAL AIR FLOW:CCR, CMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

CLR, CNR (single) . . . . . . . . . . . . . . . . . . . . . . . .25

CLW, CNW (single) . . . . . . . . . . . . . . . . . . . . . . 25

CLR, CNR (double) . . . . . . . . . . . . . . . . . . . . . . . 26

CLW, CNW (double) . . . . . . . . . . . . . . . . . . . . . 26

CVR, CVW (single) . . . . . . . . . . . . . . . . . . . . . . . 27

CVR, CVW (double) . . . . . . . . . . . . . . . . . . . . . . 28

HCD, HMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

UNIT SPECIFICATIONS:STANDARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

VERSATILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Page 3: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

3

FEATURES

Page 4: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

4

SELECTION DATA

Page 5: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

5

Page 6: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

6

CAPACITY TABLES (CCR-CMR)

Page 7: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

7

CAPACITY TABLES (CLR)

Page 8: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

8

CAPACITY TABLES (CVR)

Page 9: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

9

Page 10: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

10

CAPACITY TABLES (CNR)

Page 11: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

11

CAPACITY TABLES (CLW-CNW)

Page 12: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

12

CAPACITY TABLES (CVW)

Page 13: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

13

HEAT RECLAIM UNITS

Page 14: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

14

FAN MOTOR ELECTRICAL DATA

Page 15: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

15

Page 16: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

16

ELECTRICAL DIAGRAMS - VERSATILE MODELS

Page 17: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

17

CCR CONDENSER DIMENSIONS

2

50

24

609

39

990

17

431

29

736

33

838

2

502

50

44

1117

2

50

9/16 Ø - 4 MTG HOLES

14 Ø

123

3124

119

3022

2

50

44

1117

2

50

83

2108

79

2006

2

50

44

1117

2

50

69

863

39

990

17

431

2

50

43

1092

39

990

2

50

44

1117

2

50

34

863

39

990

2

50

17

431

2

50

2

50

9/16 Ø - 4 MTG HOLES

14 Ø

9/16 Ø - 4 MTG HOLES

14 Ø

9/16 Ø - 4 MTG HOLES

14 Ø

CMR CONDENSER DIMENSIONS

DIMENSIONS ARE IN INCHES

MM

DIMENSIONAL DRAWINGS

Page 18: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

18

Page 19: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

19

Page 20: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

20

CLX-CNX CONDENSER DIMENSIONS

DIMENSIONS ARE IN INCHES

MM

Page 21: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

21

DIMENSIONS ARE IN INCHES

MM

CLX - CNX CONDENSER DIMENSIONS (2 FANS WIDE)

Page 22: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

22

CVX CONDENSER DIMENSIONS

DIMENSIONS ARE IN INCHES

MM

Page 23: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

23

DIMENSIONS ARE IN INCHES

MM

CVX CONDENSER DIMENSIONS (2 FANS WIDE)

Page 24: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

24

Page 25: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

25

CLR - CLW - CNR - CNW CONDENSER HORIZONTAL AIR FLOW DIMENSIONS

3/4

19

169 1/2

4305

286 1/2

7277

283 1/2

7200

57

1447

57

1447

3/4

19

55 1/2

1409

57

1447

57

1447

48

1219

8 MAX

203

229 1/2

5829

226 1/2

5753

57

1447

3/4

19

55 1/2

1409

57

1447

57

1447

8 MAX

203

48

1219

172 1/2

4381

55 1/2

1409

115 1/2

2933

55 1/2

1409

112 1/2

2857

3/4

19

57

1447

57

1447

57

1447

8 MAX

203

8 MAX

203

48

1219

48

1219

54

1371

2

50

6

152

1 X 5

36 1/2

927

2

50

6

152

54

1371

2

50

1 X 4

1 X 1

1 X 2

1 X 3

32

812

2

50

32 1/2

825

28

711

58 1/2

1485

55 1/2

1409

3/4

19

8 MAX

203

48

1219

HOT GAS INLET

LIQUID OUTLET

9/16 Ø MTG HOLES

14 Ø

DIMENSIONS ARE IN INCHES

MM

Page 26: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

26

Page 27: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

27

CVR - CVW CONDENSER HORIZONTAL AIR FLOW DIMENSIONS

286 1/2

7277

283 1/2

7200

229 1/2

5829

226 1/2

5753

57

1447

3/4

19

57

1447

57

1447

3/4

19

3/4

19

Ø 9/16 - 8 MOUNTING HOLES

169 1/2

4305

55 1/2

1409

Ø 9/16 - 12 MOUNTING HOLES

55 1/2

1409

Ø 9/16 - 10 MOUNTING HOLES

57

1447

57

1447

Ø 14

57

1447

57

1447

Ø 14

Ø 14

48

1219

8 MAX

203

8 MAX

203

48

1219

172 1/2

4381

55 1/2

1409

Ø 9/16 - 4 MOUNTING HOLES

58 1/2

1485

115 1/2

2933

55 1/2

1409

55 1/2

1409

112 1/2

2857

Ø 9/16 - 6 MOUNTING HOLES

3/4

19

57

1447

57

1447

57

1447

Ø 14

3/4

19

Ø 14

8 MAX

203

8 MAX

203

48

1219

48

1219

8 MAX

203

48

1219

54

1371

2

50

6

152

1 X 5

36 1/2

927

2

50

6

152

54

1371

2

50

1 X 4

1 X 1

1 X 2

1 X 3

32

812

2

50

32 1/2

825

28

711

38 1/2

978

42 1/2

978

DIMENSIONS ARE IN INCHES

MM

Page 28: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

28

Page 29: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

29

Page 30: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

30

CCR, CMR, CLR, CLW, CLX, CNR, CNW & CNX

AIR-COOLED CONDENSER GENERAL SPECIFICATIONS

COILS are manufactured using seamless, deoxidized, heavy wall, microgroove copper tubes, mechanically expanded in self-spaced, full

collared aluminum corrugated plate fins for permanent bond and maximum heat transfer. Connections and bends are brazed with high temperature brazing alloy.The coil is factory leak tested at 400 psig using -40 ºF/ºC dew point dry air. Coils are pressurized and sealed at 20 psig before assembly.

FRICTION-FREE COIL TRACKS®All tubes sheets are provided with oversized holes and tubes are supported in sliding cushions for friction-free assembly and maximum reliability.

HEADERS are made with seamless copper tube type K OR L and connections.

CASINGS for all condensers are heavy-gauge galvanized steel G90 with plated hardware for a corrosion-free assembly.The cabinet is sectionalized with individual fan chambers. The unit is a bolted construction. Coil section is independent of the fan section. CCR/CMR models are provided with 1” punched venturies. ALL CLR, CLW, CLX, CNR, CNW & CNX models are provided with 3 3/4” high spun ven-

turies for a minimum noise and maximum efficiency.All models include side access panels for easy coil inspection and cleaning.

FANS are aluminum blades riveted to a steel hub. They are statically and dynamically balanced for smooth and vibration free operation.CCR/CMR fans are 20” in diameter with 4 blades. CLR, CLW & CLX fans are 30” in diameter with 4 blades and CNR, CNW & CNX fans are 30” in diameter with 5 blades.

FAN MOTORS feature permanently lubricated, sealed ball bearings and inherent thermal protection for long life and dependable service.

FAN GUARDS AND MOTOR MOUNTS are welded wire construction for full protection from moving parts with baked-on powder epoxy coating for corrosion protection.

OPTIONAL CONTROL PANELS can come complete with motor contactors and fuses (per motor or per pair of motors), temperature or pressure fan cycling, terminal block & control transformer.

Primary voltage is (208-240V, 480V, 600V) and secondary voltage is (24V, 120V & 240V).

ALL MOTORS ARE WIRED to weather resistance box. The unit is provided with terminal blocks for easy field installation. Terminals are clearly identified to match wiring diagram supplied with the unit. Motors are wired using flexible cord type SOW 90°C #16 AWG and they are terminated with liquid tight straight-thru fittings.

SPECIFICATIONS - STANDARD MODELS

Page 31: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

31

CVR, CVW & CVX

AIR-COOLED CONDENSER GENERAL SPECIFICATIONS

COILS

are manufactured using seamless, deoxidized, heavy wall, microgroove copper tubes, mechanically expanded in self-spaced, full col-

lared aluminum corrugated plate fins for permanent bond and maximum heat transfer. Connections and bends are brazed with high temperature brazing alloy.The coil is factory leak tested at 400 psig using -40 ºF/ºC dew point dry air. Coils are pressurized and sealed at 20 psig before assembly.

FRICTION-FREE COIL TRACKS®All tubes sheets are provided with oversized holes and tubes are supported in sliding cushions for friction-free assembly and maximum reliability.

HEADERS are made with seamless copper tube type K OR L and connections.

CASINGS for all condensers are heavy-gauge galvanized steel G90 with plated hardware for a corrosion-free assembly.The cabinet is sectionalized with individual fan chambers. The unit is a bolted construction. Coil section is independent of the fan section. ALL VER-

SATILE models are provided with 7 1/4” full bell mouth venturies. All models include side access panels for easy coil inspection and cleaning.

FANS are die cast aluminum. They are profiled in a sickle shape design for optimal sound behavior and low noise. Fan hubs are inte-

grated to the external motor rotor. They are statically and dynamically balanced for smooth and vibration-free operation. CVD, CVR, CVW & CVX fans are 31 1/2'' in diameter with 7 blades.

FAN MOTORS are totally enclosed, soft start, reverse rotor design. They feature permanently lubricated, double sealed, deep groove ball bearings.They are greased with special all temperature grease from sub zero to Class F. Motors can be single or two speed (550 or 780 RPM), Class F insulation, thermally protected, 575, 460, 208/230 3-phase 60 Hz and 400, 200 3-phase 50 Hz. Motors are designed for frequency drive; speed can be reduced down to 200 rpm. Frequency drive must have omni-pole sine filter on all phases.

FAN GUARDS AND MOTOR MOUNTS are welded wire construction for full protection from moving parts with baked-on powder epoxy coating for corrosion protection.

OPTIONAL CONTROL PANELS can come complete with motor contactors and fuses (per motor or per pair of motors), temperature or pressure fan cycling, terminal block & control transformer. Primary voltage is (208-240V, 480V, 600V) and secondary voltage is (24V, 120V & 240V). For two-speed applications, a timer, thermostat or pressure switch can be used as the last control to switch from low to high speed. An optional frequency drive can be provided for the constant operating motors or the whole condenser.

ALL MOTORS ARE WIRED to weather resistance box. The unit is provided with terminal blocks for easy field installation. Terminals are clearly identified to match wiring diagram supplied with the unit. Motors are wired using flexible cord type SOW 90°C #16 AWG and they are terminated with liquid tight straight-thru fittings.

SPECIFICATIONS - VERSATILE MODELS

Page 32: Table of content AIR COOLED CONDENSER · TYPE OF UNIT C = Condenser H = Heat Reclaim TYPE OF MOTOR C = 1/4 HP - 825 RPM M = 1/2 HP - 1140 RPM L = 1 HP - 825 RPM H = 1 1/2 HP - 825

CONDENSER-02/2016-R0

Refplus Inc. reserves the right to make any changes in the design or specifications of any product at any time without notice.

© Copyright 2016 by RefPlus Inc.USA & CANADA 1-888-816-2665 / refplus.com

2777 Grande-Allée,Saint-Hubert, Québec,Canada,J4T 2R4 T 450 641-2665 F 450 641-4554

ISO-9001

AIR-COOLED CONDENSERS AND HEAT RECLAIM UNITS