TECHNICAL RIDER SALA BARTS – BARCELONA ARTS ON STAGE (v 19-07)
BARTS is a venue located at Barcelona city centre where most important theatres are.
BARTS Avda. Paral.lel, 62 08001 BARCELONA
http://www.barts.cat
STAGE
Due to the full configuration possibilities of the venue and in order to do the best in terms of audience comfort, we have two different stage configurations as described below.
When audience is seated: Width: 9 m. Depth: 8,5 m. Slope: 0 %
When audience is standing: Width: 9 m. Depth: 7 m. Slope: 0 %
To increase audience visibility on shows with standing audience we are forced to install an extra platform on stage as described above at 0,40 m. high.
DROPERY
Main Border: Made in red velvet, fireproofed type 1 and located in BAR 0.
Front Curtain: Made in red velvet, fireproofed type 1, automatic opening in guillotine style located at BAR 1.
Borders: 4 boarders size 12 m x 2 m each, made with fireproof scenic black wool type 1.
Legs: 4, 2 pieces legs (8units total) de 7 m x 3 m, made with fireproof scenic black wool type 1.
Black Back Drop: 1 two pieces black back drop 12 m x 6,5 m, made with fireproof scenic black wool type 1
DRESSING ROOMS
There are 5 full equipped dressing rooms on 1st and 2nd floor. All of them properly lighted, with air conditioned, mirrors, make-up mirrors, tables, chairs, wardrobe and hangers, bathroom and showers.
There are as well 2 more dressing rooms -1 level down stage, full equipped with shared bathrooms and showers.
SOUND AND LIGHTING EQUIPMENT
The Venue has his own lighting and audio equipment. Sound equipment CAN NOT BE uninstalled.
As per government restrictions there is limitation of 95 dba.
SOUND EQUIPMENT
MAIN P.A. ALL FLOWN (INCLUDING SUBS)
18 (9+9) Self powered MEYER M’ELODIE speakers 6 (3+3) Self powered MEYER HP 600 speakers
FRONT-FILL
4 MEYER MM-4XP speakers
OUTFILL 2 (1+1) Self powered MEYER UPA 1P speakers.
DELAY UNDER 1st BALCONY
4 MEYER MM-4XP speakers
F.O.H. Located at the end of the audience seating area.
1 DIGICO SD8. FX’S and EQ’S on board. 1 GALILEO 616 Processor 1 TC ELECTRONIC M3000 FX Processor 1 CD player 1 Talk Back Microphone
MONITORS 1 DIGICO SD8. FX’s and EQ’s on board 6 MEYER UM-1P 4 MEYER MJF 210 1 Talk Back Microphone
IEM SYSTEMS
4 COMPLETE SENNHEISER IEM 300 G3 (Transmitter– Receiver)
4 SENNHEISER IE4 headsets
SIDEFILL 2 (1+1) Self powered MEYER speakers UPA 1P
MICROPHONE LIST
Wired microphone set consisting of 4 Senheiser E604, 1 Senheiser MD 421, 2 Senheiser MKH-416, 8 Shure SM 58, 6 Shure SM 57, 2 Shure Beta 98 Horn clip, 1 Shure Beta 52, 2 Shure Beta 57A, 2 Shure Beta 58A, 1 Shure Beta 91A, 2 Shure PG 48 w/switch, 2 DPA 4066 omni headset, 2 DPA 4061 FM, 3 Neumann KM 184, 2 AKG 414, 2 Neumann KMS 105, 2 AKG 300B equipped with CK 93 capsule, 12 active D.I. Box BSS AR 133…
Set of wireless microphones consisting OF 8 complete SENNHEISER Evolution G3 systems, including 4 hand transmitter and 4 belt packs. Microphone stands needed (18 tall + 12 shorts) Cables needed
INTERCOM SYSTEM
1 Main station located at the cabin on 2nd floor 1 Remote station fixed on stage right 8 Wired belt packs
LIGHTING EQUIPMENT
LAMPS 18 Rockettes PAR 64 1000 w CP62 / nº 5 4 PC 1000 w 4 PC 2000 w 8 Profile Robert Juliat 1000 w 9 Profile Robert Juliat 2000 w 6 Martin MAC 600 4 Martin MAC 500 8 Martin 301 Wash 6 Martin MAC 2000 Profile 6 JARAG-5 PAR 30 CHROMELECH (blinders) 2 FLASH ATOMIC 3000 2 Fog Machines LOOK (UNIQUE 1500 w) 1 Lighting desk ETC Element 40 1 Lighting desk AVOLITES Pearl 2008
Working light on stage during set up and unset.
DIMMERS 168 3 Kw Dimmer channels. 18 5 Kw Dimmer channels.
HOUSE LIGHTS
House lights can be controlled through the Show light desk to have an easy access when opening the hall and starting/ending the show.
LIGHTING PLOT Companies light equipment will be adapted as much closer as possible to the following light plot:
VIDEO (Optional) 1 Video Projector CHRISTIE ROASTER HD 18K 1 Lens CHRISTIE ROADSTER 1.45-1.1:1
LX VARA 10
LX VARA 20
15º
40º recorte 2Kw
Robert Juliat 714 sx 15º/40º 710 sx 10º/25ºrecorte 1KwRobert Juliat 614 s 16º/35º
PAR 64 CP62
Martin Mac 500(dmx 4, 16 chs)
Martin Mac 600(dmx 4, 14 chs)
PC 2KwSpotlight Vario 25
2322
26 27
5958
24
28
61
15º40º
410º25º
115º40º
315º40º
215º40º
715º40º
815º40º
610º25º
5
LX VARA 4
LX VARA 16
LX VARA 24
LX PUENTE SALA
53 5451 52 55 56
10º25º
9
21 25
33
57 62
63 64 65 66 67 6849 407388
426
73
369350 9725293
312 331
1 121
279
265
251
209
223
237
145 193161 177
10
GO
BO
BA
RTS
Mac 2000 Profile II(dmx 4, 24 chs)
Mac 301 Wash(standard RGB 16b, 19 chs)
VARA 8
VARA 7
VARA 13
VARA 14
VARA 18
VARA 19
VARA 22
VARA 23
VARA 26
IMPLANTACIÓN BASE BARTS 2018
DISTRIBUCIÓN DMX
DMX 1 DMX 2
DIMMERS,SMOKE MACHINES(497 SR & 499 SL),
HOUSE LIGHTS(501~509+167),JARAG 5 par30,
GOBO BARTS (10),
Mac 2000 Profile IIMac 301 Wash
Mac 500Mac 600
Strobos Atomic 3000
445 449
Martin Atomic 3000(4 chs)
34
363 394 425 456332301
LX PUENTE BOCA
Asimétrico 1kwSpotlight Domino
Chromlech Jarag 5 par30(31 chs)ESCENARIO
ESCENARIO
ES
CE
NA
RIO
ES
CE
NA
RIO
IMPLANTACIÓN BASE BARTS 2018
12
11 11
12
31 32
DIMMER ADDRESS
LOAD IN-OUT ACCESS
Load in access will be done through the door located at Abad Safont Street.
The door is 1,90 m wide x 3,70 m high and gives access to a lifter with direct access to the stage.
The lifter is 2,20 m x 1,90 m and has a maximum load lift of 2000 kg.
Access to loading area is done from Ronda Litoral Exit 21 - Paral·lel