12
The QUICKEST way to wire. For recessed-ceiling, open-ceiling and power applications. The #1 Selling Modular Wiring Solution Since 1977

The QUICKEST way to wire

Embed Size (px)

Citation preview

Page 1: The QUICKEST way to wire

The QUICKESTway to wire.

For recessed-ceiling,open-ceiling andpower applications.

T h e # 1 S e l l i n g M o d u l a r W i r i n g S o l u t i o n S i n c e 1 9 7 7

Page 2: The QUICKEST way to wire

the RELOC®AdvAntAgE

RELOC® Wiring Solutions

In today’s fast-paced construction

market, staying on schedule and under

budget is tougher than ever. Every job

demands wiring solutions that reduce

installation time and adapt to changes,

whether they occur during construction

or after a building is occupied. With rising

labor costs and the shortage of qualified

electricians, traditional wiring methods no

longer measure up.

RELOC Wiring Solutions from Acuity Brands

Lighting has been the leader in modular

wiring since 1977. RELOC offers three

unique wiring systems that are fast, easy

and effective: Quick-Flex® wiring for

recessed ceiling lighting installations,

OnePass® system for open-ceiling lighting

installations and System 820 for specialty

lighting and power applications.

• Innovative,patentedproducts

• Lowesttotaljobcost

• Easyprojectmanagement

• Fastestimatingandsimpleordering

• Easyfixturerelocation

• Safetyandreliability

Page 3: The QUICKEST way to wire

Easy Fixture Relocation

Complete wiring changes quickly

and inexpensively by reusing RELOC

components. Simply unplug the original

system, relocate the fixtures and

reconnect the system. Quick changes

minimize facility down-time.

Safety and Reliability

All RELOC components are 100-percent

electrically tested. Safety features such

as dead-fronted contacts are designed to

comply with UL183 and CSA 22.2 203.1

(standard for manufactured wiring sys-

tems) and 2008 NEC 410.130 (G) and

CEC 30-308 (ballast disconnective means)

while following standard safety practices.

RELOC Wiring Offers Lowest total Job Cost vs.traditional Wiring Methods

Quick-Flex®

1 OnE

OnePass®

System 820

New York City Approved

Calendar Numbers 47802, 48072 and 48273

Lowest total Job Cost

RELOC components snap together in a frac-

tion of the time it takes to wire a fixture with

conventional wiring methods — and require

less labor and fewer materials. Installation

time is reduced by up to 66 percent, result-

ing in significantly reduced total job cost.

Easy Project ManagementRELOC wiring enhances the ability to

plan and manage a tight schedule. Since

RELOC wiring is installed with fixtures in

the finish phase, labor, material costs and

trade conflicts are reduced during the

critical rough-in stage.

Fast Estimating and Simple Ordering

RELOC estimating tools provide fast project

estimates and simple ordering, eliminat-

ing the need for time-consuming factory

drawings.

RELOC products are a greener solution than traditional wiring. RELOC products minimize installation time and construction waste while maximizing productivity, reusability and the use of recycled materials.

Please see www.acuitybrandslighting.com/sustainability for more information.

Manufactured wiring systems are described in NEC 604 and

Canadian CEC 12-2500.

All products are UL Listed, NYC Approved and C-UL Listed

or CSA Certified.

Reduce, Reuse, Recycle. . .RELOC®RECYCLE R

EDUCE

REUSE

Page 4: The QUICKEST way to wire

Quick-Flex Standard Features With only three basic components, the

Quick-Flex system snaps together in a fraction of the time it

takes to wire a fixture with MC Cable. There is no need for

tools, factory estimating or drawing services. Due to faster

installation, labor costs are dramatically reduced, cutting

down the total job cost.

The Quick-Flex system is ideal for wiring lay-in troffers,

parabolics, downlights, indirect fixtures and emergency lighting

equipment in office buildings, schools and retail stores.

• The Quick-Flex fixture combo is shipped standard with an access plate (as shown in the photo below). These access plates have one pre-punched knockout to speed the installation of Lithonia troffers and parabolics. For downlights or non-Lithonia fixtures, discard access plate and install fixture cable directly to any 1/2” knockout.

• UL Listed autoground – Fixtures are grounded automatically as soon as the access plate is snapped in place. No ground leads to connect.

• Auto-latching springs allow for an easy, secure connection and prevent accidental disengagement.

Factory-Installed Combo OptionThe Quick-Flex fixture cable (QFC) can be prewired to the fixture in the factory. Both the fixture and Quick-Flex cable are shipped together. This reduces the amount of time spent sorting materials at the job site. It also cuts on-site disposal costs. This option is ideal for jobs with 100 or more fixtures of the same type, using the same Quick-Flex fixture cable.

See page 3 for ordering information.

1) One QFC cable per fixture2) One QC converter per circuit run3) 10% QE cables and 3% QS splitters (spare parts)

Quick-Flex Wiring is Easy to Estimate

Ask your local Acuity Brands Lighting representative for your RELOC 1-2-3 price guarantee.

tWO 2

Dust covers are not included

with combo option and must

be ordered separately.

Quick-Flex®

recessed-ceilingwiring is fasterand easierto install thanMC Cable® or other modular wiring systems.

Page 5: The QUICKEST way to wire

35% Savings On total Installed

Cost

Switching Solutions

For best results, install Quick-Flex switch drops during the rough-in stage. Add a Quick-Flex extender between the switch drops during the finish phase when the fixtures and QFC cables are installed.

Cost Savings = ______

Materials

*Basedonatypicalsingle-circuit,30-fixtureapplicationon10-footcenterswitha$55/hr.laborrate(USD).

$385.00

$677.00

$1062.00 $681.00

$136.00

$545.00

Labor

total*

MC Cable Quick-Flex

3 tHREE

How To Order Fluorescent Combo Option Lithonia Lighting fixture with Quick-Flex fixture cable attached and prewired.Example: RELOC QFC277 12/3G11 becomes luminaire option QFC311GAB 2SP8 G 3 32 A12 347 GEB10IS QFC311GABSpecifying wiring option: Wiring Option 2 conductors (1 hot) ex: QFC2 (length) xx 3 conductors (2 hot) ex: QFC3 (length) xx

A All ballasts/inverters on "A" circuit. B All ballasts/inverters on "B" circuit. AB Outboard lamps on "A", inboard on "B" (If fixture contains 2 ballasts plus an inverter, the inverter will be located at the access plate. Not connected to a QFC supplied circuit.) AE All ballast(s) on "A", inverter on "B". NW Access plate with knockouts installed Access plate with knockouts installed in fixture. RELOC included with fixture, in fixture. RELOC included with fixture, not wired. not wired.

35%

If MC Cable is used between switches, Quick-Flex wiring can provide a simple and efficient link from the switchbox to the fixtures on the switched circuit.

Page 6: The QUICKEST way to wire

OnePass® open-ceiling wiring simplifiesthe installation of high bay fixtures.

25% Savings On total Installed

Cost

OnePass Standard Features

Traditional hardwiring requires three or more passes to install conduit, pull wire and hang fixtures. Using the OnePass system, only three basic components and one pass are needed. Faster installation reduces labor costs and the total job cost. Plus, there is no need for factory estimating or drawing services.

The OnePass system is ideal for installing HID and fluorescent fixtures in manufacturing facilities, warehouses, retail facilities and any other open-ceiling fixture applications.

• The OnePass system is listed for open accessible ceilings and dry locations, meeting or exceeding the UL 183 and 22.2 203.1 requirements, the National Electrical Code and Canadian Standards.

• All components are easy to install and relocate, featuring easy-to-grip cable heads and self-latching springs that simply plug together.

• OnePass wiring is rated at 20A with 90ºC 12 AWG conductors. The OnePass OC2 cable also is available in a 10AWG, 20A option to reduce voltage drop on longer runs.

• All components are keyed to prevent different voltages from connecting, and color-coded cable heads allow for easy identification.

OnePass Factory-Installed OptionUse the following guidelines to order fixtures with OnePass pre-installed.

• Add OCS to the description: Example IB 454 277 LP835A OCS. Consult factory for other options.

• For four or five conductor fixture drops, follow the same guidelines as above, except tap positions must now be specified for the OCU product. Example: OCU122N = 5' white cord with two hots, two dedicated neutrals and a ground. Example: OCU2310 = 10' white cord with two hots and one neutral.

FOUR 4

Page 7: The QUICKEST way to wire

1) One OCS per fixture2) One OC2 cable for each fixture3) One OC per circuit run

OnePass Wiring is Easy to Estimate

Ask your local Acuity Brands Lightingrepresentative for your RELOC1-2-3 price guarantee.

Cost Savings = ______

Materials

*Basedonatypicalsingle-circuit,30-fixtureapplicationon20-footcenterswitha$55/hr.laborrate(USD).

$700.00

$2062.00

$2762.00 $2092.00

$825.00

$1267.00

Labor

total*

Pipe & Wire OnePass

5 FIvE

21G N3

Position 1

Circuit Selection at Every FixtureThe OCS is a polarized plug-in connection for industrial fixtures, featuring a patented thumbslide action. Just choose the desired hot conductor(s) needed to energize each fixture. Simply slide the circuit selector to position 1, 2 or 3 and plug the fixture into the system. No more worrying about coordinating different-circuited fixtures. The OCS permits removal of any fixture from the branch circuit without additional components or interruption in the branch circuit.

All cables now available in custom colors.

For details, contact the factory at 1-800-541-4750.

nEW

25%

Page 8: The QUICKEST way to wire

SIX 6

Quick-Flex® Components

Recessed-Ceiling Lighting SystemExample: QC120 12/3g

Quick-Flex dust CoverDustcoverisrequiredtoprotectunusedportsinaRELOCsystemperNECArticle604.7.QUICK FLEX dUSt COvER J50

QFC

Family QFC Quick-

Flexfixturecable

Size and no. of conductors12/2g12/3g

QFC - Fixture Cable1 Male/female cable provides power from fixture to fixture. Access plate is preattached.

voltage 120 120V 277 277V 347 347V

Length 09 9feet 11 11feet 13 13feet 15 15feet

Optional ground lead g No.18AWGground

leaddroppedtofixture(REQUIREd In CAnAdA)

QSFC

Family QSFC Quick-

Flexstarterfixturecable

voltage 120 120V 277 277V 347 347V

QSFC - Starter FixtureCable1 Combination of converter (QC) and fixture cable (QFC).

Length 09 9feet 11 11feet 13 13feet 15 15feet

Size and no. of conductors12/2g12/3g

Optional ground lead g No.18AWGground

leaddroppedtofixture(REQUIREd In CAnAdA)

QC

Family QC Quick-

Flexconverter

voltage120120V277277V347347V

Size and no. of conductors12/3g

QC - Converter Provides interface between hardwiring and Quick-Flex wiring at the homerun location.

12/3g

QE - ExtenderMale/female cable providesadditional length anywhere within the system.

QE

Family QE Quick-

Flexextender

Size and no. of conductors12/2g12/3g

voltage 120 120V 277 277V 347 347V

Length 09 9feet 11 11feet 15 15feet 21 21feet

Family QSd Quick-

Flexswitchdrop

QSd - Switch dropProvides local switched power forfixtures as well as the ability tocarry on unswitched power throughthe use of a QE.

QSd

Size and no. of conductors1LEvEL2LEvEL

1LEvEL/n

voltage 120 120V 277 277V 347 347V

Length 01 1foot 09 9feet

QPt - Power teeProvides hardwire connection to any electrical device.

QPt

Family QPt Quick-

Flexpowertee

Size and no. of conductors12/3g

12/3g

voltage 120 120V 277 277V 347 347V

Length 01 1foot 09 9feet 15 15feet

QS - SplitterMale/female component that can be used anywhere in the system. Separates branch circuit into two directions.

QS

Family QS Quick-

Flexsplitter

Size and no. of conductors12/3g

12/3g

voltage 120 120V 277 277V 347 347V

nOtES:1 Furnishedwithpokehomeconnectorsforeasyconnectiontofixturewires.

Page 9: The QUICKEST way to wire

7 SEvEn

OnePass® Components

Open-Ceiling Lighting System

nOtES:1 Fortwoneutralapplications,specify2N(10/4Gand12/4Gonly).Consultfactoryforotheroptions.2 Pleaseconsultfactorywhenordering208V,240Vor480V.3 Use12/4Gproductfor10GA,20Asystems.4 16AWGrubberizedcordratedfor600V,105ºCwithfullyratedgroundconductor.5 Whitecordstandard.Blackcordrequireslongerleadtime.

Example: OC 277 12/4g

OnePass dust CoverDustcoverisrequiredtoprotectunusedportsinaRELOCsystemperNECArticle604.7.RdC3 MEtAL dUSt COvER CSA/UL J50

OC - ConverterProvides interface between

hardwiring and RELOC wiring at homerun location.

OC

Family1

OC OnePassconverter

Size and no. of conductors3

12/4g

12/4g

voltage120 120V208 208V2240 240V2277 277V 347 347V480 480V2

OSC2 - Starter CableProvides interface between

hardwiring and RELOC wiring system.

OSC2

Family1

OSC2 OnePassstartercable

Size and no. of conductors12/2g12/3g12/4g10/2g10/3g10/4g

Cable length09 9feet15 15feet21 21feet25 25feet31 31feet

voltage 120 120V 208 208V2 240 240V2 277 277V 347 347V 480 480V2

OC2 - two-Port CableProvides feed-through and tap in

one component. Acts as an extension cable between fixture connections.

OC2

Family1

OC2 OnePasstwo-portcable

Size and no. of conductors12/2g12/3g12/4g10/2g10/3g10/4g

voltage 120 120V 208 208V2 240 240V2 277 277V 347 347V 480 480V2

Cable length09 9feet15 15feet21 21feet25 25feet31 31feet

OCS - Circuit SelectorA polarized plug-in connector for

industrial fixtures. Allows on-site circuit selection of desired hot conductor(s).

Prewired by fixture manufacturer or field installed by contractor.

OCS

Family4

OCS OnePasscordwithcircuitselector

Cable length 05 5feet 10 10feet 15 15feet 20 20feet

WH Whitecord BK Blackcord

Cord colors5voltage 120 120V 208 208V2 240 240V2 277 277V 347 347V 480 480V2

tAP2 2 tAP12 1and2 tAP34 3and4 tAP1 1 tAP3 3 tAP23 2and3 tAP123 1,2and3

OCU

Family1,4

OCU OnePasscordunselect-able

tap positionOCU - Cord Unselectable

A polarized, non-circuit selectable plug-in connection for industrial

fixtures. Prewired by fixture manufac-turer or field installed by contractor.

WH Whitecord BK Blackcord

Cord colors5voltage 120 120V 208 208V2 240 240V2 347 347V 480 480V2

Cable length05 5feet10 10feet15 15feet20 20feet

Od - drop CableAllows miscellaneous devices (exits, etc.) to become part of the system.

Od

Family1

Od OnePassdropcable

Size and no. of conductors12/2g12/3g12/4g

voltage 120 120V 208 208V2 240 240V2 277 277V 347 347V 480 480V2

Cable length 05 5feet 10 10feet 15 15feet 20 20feet

OSS - Splitter SpliceMale/female component that can be

used anywhere in the system. Separates branch circuit into two

directions.

OSS

Family1 OSS OnePass

splittersplice

Size and no. of conductors3

12/4g

12/4g

voltage 120 120V 208 208V2 240 240V2 277 277V 347 347V 480 480V2

Page 10: The QUICKEST way to wire

EIgHt 8

System 820

Specialty Power and Lighting SystemExample: Cd 120 F

820 dust CoverDustcoverisrequiredtoprotectunusedportsinaRELOCsystemperNECArticle604.7.RdC3 MEtAL dUSt COvER CSA/UL J50

Cd - Circuit distributor Provides interface between hardwiring and RELOC wiring system.

Cd

Family

Cd

voltage 120 120V 277 277V 347 347V

no. of conductors d Three E Four F Five

Options IgW Isolatedground

wire;availablewith120VandFconductoronly

2n Twocircuit,twoneutral;Fcon-ductorsonly

CE - Cable Extender Male/female cable that provides additional length anywhere throughout the RELOC system.

CE

Family

CE

Factory keying

U

Cable length

09 9feet 11 11feet 15 15feet 21 21feet 25 25feet

U

Options IgW Isolatedground

wire;availablewith120VandFconductoronly

2n Twocircuit,twoneutral;Fconduc-torsonly

no. of conductors d Three E Four F Five

voltage 120 120V 277 277V 347 347V

SSC - Standard Selector CableMale/female cable, provides power from fixture to fixture. Attaches to access plate or through 1/2” trade-size knockout by means of poke home connectors.

no. of conductors d Three E Four F Five

FamilySSC

SSC

Factory keying

U

U

voltage120 120V277 277V347 347V

Cable length

09 9feet 11 11feet 13 13feet 15 15feet

Options 2n Twocircuit,two

neutral;Fconduc-torsonly

g Groundleadwithlugterminal(REQUIREd In CAnAdA)

SS - Splitter SpliceUsed to split branch circuit into two directions in commercial or power applications.

SS

Factory keying

U

UF

no. of conductors F Five

voltage120120V277277V347347V

Options

IgW Isolatedgroundwire;availablewith120VandFconduc-toronly

2n Twocircuit,twoneutral;Fconduc-torsonly

FamilySS

CSU - Circuit Selector UnitProvides wiring of any device through 1/2" trade-size knockout. CSU uses No. 12 AWG leads, allowing full circuit access.

CSU

Family

CSU

Factory keying

U

UF

Options IgW Isolatedgroundwire;

availablewith120VandFconductoronly

2n Twocircuit,twoneutral;Fconductorsonly

no. of conductors F Five

voltage 120 120V 277 277V 347 347V

Page 11: The QUICKEST way to wire

9 nInE

System 820

Specialty Power and Lighting System

dC - drop CableProvides integration of other electrical devices into the 820 system, such as

power outlets and power strips.

dC

Cable length 09 9feet 11 11feet13 13feet15 15feet

voltage 120 120V 277 277V 347 347V

FamilydC

Options IgW Isolatedground

wire;availablewith120VandFconductoronly

2n Twocircuit,twoneutral;Fconduc-torsonly

U

voltage 120 120V

dUP

SeriesdUP

number of duplexes

(blank) One 2 Two

no. of conductorsd Three E Four F Five

A120

OptionsIgW Isolatedground

wire;availablewithEandFcon-ductorsonly(addonlyifrequired)

Hot receptacle position

1 One 2 Two 3 Three

dUP - duplex ReceptacleThe DUP is a prewired power

receptacle outlet box that integrates with a RELOC system. The DUP can be used to manage phase loading on power receptacle applications.

Pre-order the appropriate number of receptacles for each circuit prewired

from the factory.

Pt - Power teeProvides hardwire connections to

any electrical device.

Pt

drop type A Armored

Options IgW Isolatedground

wire;availablewith120V;EandFconductorsonly

2n Twocircuit,twoneutral;Fconduc-torsonly

voltage 120 120V 277 277V 347 347V

FamilyPt

AF

RRCA - Replacement RELOC Cord Assembly

Ideal for retrofitting projects done with old RELOC system. Prewired by fixture

manufacturer or field installed by the contractor.

RRCA

Cable length 05 5feet

FamilyRRCA2

Cord color WH White

F 05 WH

tap position 123 1,2and3

(120V or 277V) 1234 1,2,3and4

(208Vor 480V)

voltage 120 120V208 208V347 347V480 480V

nOtES:1 PowerTee(PT)isavailableinfive-conductoronlywithDUPproduct.2 RRCAissoldonlywithwhitecordandfive-wireconfiguration.

Factory keyingU

no. of conductors

d Three E Four F Five

no. of conductors

F Five

no. of conductors

F Five1

Cable length

01 1foot03 3feet09 9feet15 15feet

tap position 1 1 2 2 3 3 12 1and2 13 1and3 23 2and3 123 1,2and3

Interface componentPt Powertee1

dC Dropcable

Cable length

011foot055feet

droptype A Armored

Page 12: The QUICKEST way to wire

RELOC products are a greener solution than traditional wiring. RELOC products minimize installation time and construction waste while maximizing productivity, reusability and the use of recycled materials.

Please see www.acuitybrandslighting.com/sustainability for more information.

Reduce, Reuse, Recycle. . .RELOC®

RECYCLE RED

UCE

REUSE

One Lithonia Way, Conyers, GA 30012 | TEL 800.241.4750 | FAX 770.808.8650 | www.relocwiring.com © 2011 Acuity Brands Lighting, Inc., All Rights Reserved. 06/11 R6980 Form No. 670.208