104
TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document contains export-controlled technical data whose export is restricted by the Army Export Control Act (Title 22, US C, Sec2751 et deq)or Executive Order 12470 Violation of these export laws are subject to severe criminal penalties. DISTRABUTION STATEMENT C Distribution authorized to U.S. Government agencies and their contractors to protect technical or operational information from automatic dissemination under the International Exchange Program or by other means. This determination was made on 13 Nov 1986. Other requests for this document will be referred to Technical Director, U S Army Edgewood Research, Development and Engineering Center ATTN SCBRD EN-V, Aberdeen Proving Ground MD 21010-5423. DESTRUCTION NOTICE - Destroy by any method that will prevent \ disclosure of contents or reconstruction of the document. HEADQUARTERS, DEPARTMENT OF THE ARMY 17 NOVEMBER 1995

TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

  • Upload
    hatruc

  • View
    320

  • Download
    9

Embed Size (px)

Citation preview

Page 1: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR'S MANUAL

SIMPLIFIED COLLECTIVE

PROTECTION EQUIPMENT: M20A1

(NSN 4240-01-330-7806)

WARNING - This document contains export-controlled technical data whose export isrestricted by the Army Export Control Act (Title 22, US C, Sec2751 et deq)or ExecutiveOrder 12470 Violation of these export laws are subject to severe criminal penalties.

DISTRABUTION STATEMENT C Distribution authorized to U.S. Government agenciesand their contractors to protect technical or operational information from automaticdissemination under the International Exchange Program or by other means. Thisdetermination was made on 13 Nov 1986. Other requests for this document will bereferred to Technical Director, U S Army Edgewood Research, Development andEngineering Center ATTN SCBRD EN-V, Aberdeen Proving Ground MD 21010-5423.

DESTRUCTION NOTICE - Destroy by any method that will prevent \ disclosure ofcontents or reconstruction of the document.

HEADQUARTERS, DEPARTMENT OF THE ARMY

17 NOVEMBER 1995

Page 2: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

WARNING

TOXIC HAZARD

Decontaminate all contaminated equipment and personnel before erecting Simplified CollectiveProtection Equipment (SCPE).

When erecting SCPE in a toxic environment, protective mask and clothing must be worn by allpersonnel until SCPE is deployed and operational. The level of protective clothing will bedetermined by the unit commander.

When SCPE is deployed in a toxic environment, it may take up to 1-1/2 hours from time blower isturned on to purge liner of toxic vapors. Personnel who must enter SCPE during 1-1/2 hourpurge time shall wear clean, uncontaminated protective clothing. Failure to do so could result inprolonged purge time and recontamination of personnel.

Do not locate blower near an area where exhaust gasses are generated because filter will notremove carbon monoxide.

NOISE HAZARDThe blower operating noise may be hazardous to operator hearing. Hearing protection must beworn when remaining within 4 feet of blower in operation.

INJURY HAZARDThree major components of SCPE weigh approximately 100 pounds each. Lifting and/or carryingcan be accomplished by no fewer than two personnel.

Improper lifting of PE top when erecting may cause back strain to personnel. To avoid backstrain follow, proper lifting procedures.

Sharp edges of the filter canister can cause injury to personnel. Use care when connecting ordisconnecting air ducts to filter.

Keep hands clear of leg hinges when erecting or striking protective entrance (PE).

FIRE HAZARDKeep flame, spark and heat clear of SCPE.

HIGH VOLTAGEHigh voltage exists in motor blower and recirculation filter. To prevent electrical shock ensuremotor blower power switch is in off (down) position before connecting or disconnecting powercable.

Disconnect power cable before performing any maintenance procedures.

FIRST AIDFor first aid information, refer to FM 21-11.

a/(b blank)

Page 3: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Technical Manual HEADQUARTERSNo. 34240-413-10 Department of the Army

Washington, D.C., 17 November 1995OPERATOR'S MANUAL

FOR

SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1

(NSN 4240-01-330-7806)

REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS

You can help improve this manual. If you find any mistake or if you know of a way toimprove the procedures, please let us know. Mail your letter or DA Form 2028(Recommended Changes to Publications and Blank Form) direct to: Technical Director,U.S. Army Edgewood Research, Development and Engineering Center, ATTN: SCBRD-ENL-V, Aberdeen Proving Ground, MD 21010-5423. A reply will be furnished to you.

WARNINGThis document contains export-controlled technical data whose export is restricted by the ArmyExport Control Ac (Title 22, U.S.C., Sec 2751 et seq) or Executive Order 12470. Violation of theseexport laws are subject to severe criminal penalties.

DISTRIBUTION STATEMENT C: Distribution authorized to U.S. Government agencies and theircontractors to protect technical or operational information from automatic dissemination underthe International Exchange Program or by other means. This determination was made on 13 Nov86. Other requests for this document will be referred to: Technical Director, U.S. ArmyEdgewood Research, Development and Engineering Center, ATTN: SCBRD-ENL-V, AberdeenProving Ground, MD 21010-5423.

DESTRUCTION NOTICE Destroy by any method that will prevent disclosure of contents orreconstruction of the document.

TABLE OF CONTENTSPage

HOW TO USE THIS MANUAL ............................................................................................ iv

CHAPTER 1 INTRODUCTION ................................................................................................................ 1-1

Section I General Information ............................................................................................................ 1-1

Section II Equipment Description and Data ......................................................................................... 1-3

Section III Principles of Operation .................................................................................................. 1-10

i

Page 4: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

TABLE OF CONTENTS (CONT)Page

CHAPTER 2 OPERATING INSTRUCTIONS ........................................................................................... 2-1

Section I Description and Use of Operators Controls and Indicators ................................................... 2-2

Section II Preventive Maintenance Checks and Services (PMCS) ...................................................... 2-5

Section III Operation Under Usual Conditions ...................................................................................... 2-22

Section IV Operation Under Unusual Conditions .................................................................................. 2-63

CHAPTER 3 MAINTENANCE INSTRUCTIONS ...................................................................................... 3-1

Section I Lubrication Instructions ....................................................................................................... 3-1

Section II Troubleshooting Procedures ................................................................................................ 3-1

Section III Maintenance Procedures .............................................................................................. 3-5

APPENDIX A REFERENCES ................................................................................................................... A-1

APPENDIX B COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS UST ....................................... B-1

APPENDIX C ADDITIONAL AUTHORIZATION UST (AAL) ............................................................................... C-1

APPENDIX D EXPENDABLE AND DURABLE ITEMS LIST............................................................................... D-1

ALPHABETICAL INDEX .....................................................................................................Index-1

ii/(iii blank)

Page 5: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

M20A1 Simplified Collective Protection Equipment

1-0

Page 6: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

CHAPTER 1INTRODUCTION

Section I. GENERAL INFORMATION

1-1. SCOPE.

a. Type of Manual. This is the operator's manual for use with the M20A1 Simplified Collective ProtectionEquipment (SCPE).

b. Equipment Name and Model Number. Simplified Collective Protection Equipment: M20Al

c. Purpose of Equipment. The SCPE provides a clean-air shelter for use against chemical and biological warfareagents and radioactive particles. The SCPE is an inflatable shelter which allows personnel to perform duties withoutwearing individual protective equipment.

d. Special Limitations. The M20A1 SCPE should be deployed in a structurally sound building. It MUST NOT bedeployed outside, where it would be subject to wind, rain, solar heat loading, or direct contact with liquid agents. TheSCPE does not provide:

(1) Environmental control equipment (heating and cooling); however, interfaces are provided.

(2) A portable source of electrical power (electrical generator).

(3) NBC detection devices.

(4) Protection from nuclear radiation, however, the SCPE does provide protection against radioactiveparticles.

(5) Protection from carbon monoxide exhaust gasses.

1-2. MAINTENANCE FORMS AND RECORDS.

Department of the Army forms and procedures used for equipment maintenance will be those prescribed by DAPAM 738-750, The Army Maintenance Management System (TAMMS).

1-3. DESTRUCTION OF ARMY MATERIEL TO PREVENT ENEMY USE.

For SCPE destruction procedures to prevent enemy use, refer to TM 43)0002-31 Destruction of ChemicalWeapons and Defense Equipment to Prevent Enemy Use.

1-4. REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATION (EIR).

If your SCPE needs improvement, let us know. Send us an EIR You, the user, are the only one who can tell uswhat you don't like about your equipment. Let us know why you don't like the design or performance. Put it on aStandard Form 368, Quality Deficiency Report. Mail it to us at Armament and Chemical Acquisition and LogisticsActivity, ATTN: AMSTA-AR-QAW-A, Rock Island, IL 61299-6000. We will send you a reply.

1-1

Page 7: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

1-5. CORROSION PREVENTION AND CONTROL (CPC).

a. Corrosion Prevention and Control (CPC) of Army material is a continuing concern. It is important that anycorrosion problems with this item be reported so that the problem can be corrected and improvements can be made toprevent the problem in future items.

b. While corrosion is typically associated with rusting of metals, it can also include deterioration of other materialssuch as rubber and plastic. Unusual cracking, softening, swelling, or breaking of these materials may be a corrosionproblem.

c. If a corrosion problem is identified, it can be reported using Standard Form 368. Use of key words such as"corrosion," "rust," "deterioration," or "cracking" will assure that the information is identified as a CPC problem.

d. The Standard Form 368 should be submitted to:

DirectorU.S. Army Armament and Chemical Acquisition and Logistics ActivityATTN: AMSTA-AR-QAW-A/ Customer Feedback CenterRock Island, Illinois 61299-6000

1-6. NOMENCLATURE CROSS-REFERENCE LIST.

Common Name Official Nomenclature

Gage Differential Pressure GageM20Al SCPE Simplified Collective Protection Equipment: M20Al

1-7. LIST OF ABBREVIATIONS.

A AmpereBTU British Thermal Unitcfm Cubic feet per minutecm CentimeterDOT Department of TransportationECU Environmental Control UnitHSFC Hermetically Sealed Filter CanisterHz Hertziwg Inches of water gagekg Kilogramkw Kilowattm MeterNA Not ApplicableNBC Nuclear, Biological, ChemicalPE Pressurized Protective EntranceVAC Volt Alternating CurrentVDC Volt Directing Current

1-2

Page 8: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section II. EQUIPMENT DESCRIPTION

1-8 EQUIPMENT CHARACTERISTICS, CAPABIUTIES, AND FEATURES.

a Characteristics.

(1) Transported by truck.

(2) Operates from 110/220 VAC, 50/60 Hz power.

(3) Easily maintained.

(4) System can be deployed using two people.

b. Capabilities and Features.

(1) Includes liquid agent resistant liner.

(2) Provides a recirculation filter which filters and cleans air inside the shelter.

(3) Has a PE that allows personnel to move from a contaminated area into the protective shelter without introducing contaminants.

(4) Can be operated without HSFC when system is used for training.

(5) Accessory package contains material and repair tape for restoring damaged liners, hoses, and PE tousable condition.

(6) Provides adapters to interface with environmental control unit (ECU). Two types of MIL-A-52767 ECU can be interfaced:

Type 1, Size C, 18,000 BTU compact vertical air conditioner orType 2, Size C, 18,000 BTU compact horizontal air conditioner.

(7) On-board spare gaskets to repair air duct hose adapter and filter adapter are stored in the accessorypackage.

1-3

Page 9: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

1-9. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS.

The M20A1 SCPE has five major components:

• Room Liners

• PE

• HSFC

• Recirculation filter

• Accessory package with motor blower.

a Room Liners The room liner (1) is sealed in a protective plastic bag and packed in rubber-coated-fabric linercarrier bag. Liners are made from plastic film that is resistant to toxic liquids and gasses. When a PE is attached andliner is pressurized, it provides a protective area for personnel. Room liners (1) of two or more complete systems can beattached to one another with a room adapter (2) (included in liner package) to increase protective area. Exterior loopsand ties (3) on the top of the liner can be used to provide unpressurized support for the room liner (1). Each M20A1SCPE is issued with three complete room liner packages (two are on-board spares).

1-4

Page 10: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

b. Protective Entrance (PE). Consists of a collapsible aluminum support frame (1) and a butyl coated fabric(2) enclosure. When erected, the PE is free standing. It is triangular in shape with fabric doors (3) on each side. Eachdoor has a window (4), slit entrance with hook-and-pile fasteners (5), and hook-and-pile operated vents (6). One side hasa flange (7) that is used to connect the PE to the room liner. The flange comes with two air duct sleeves (8). The outeredge of the flange has a mating hook-and-pile fastener (9). The PE also comes with interval timer (10), two gages (11),dome light (12), and power supply (13). Two carrying handles (14) are located on the top. One cable sleeve (I5) islocated on the inside door.

1-5

Page 11: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

1-9. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (CONT).

c. Hermetically Sealed Filter Canister (HSFC). Contains gas and particulate filters which remove chemical andbiological agents and radioactive particles. The HSFC is connected to the motor blower by the short air duct and to theSCPE liner through the PE by the long air duct (not shown). The HSFC (1) is hermetically sealed until pull-tabs (2) areremoved. The HSFC remains in its shipping crate (3) for normal use.

d. Recirculation Filter. The recirculation filter is a portable self-contained unit. It is used to filter any residual NBCcontaminants inside a deployed SCPE liner. The cover (1) is attached to the case (2) by four link-lock fasteners (3). Thecase (2) houses the blower and the power switch (4). The power cord (5) plugs into the PE power supply and provides110 VAC, 50/60 Hz to the blower. Air enters through the air inlets (6) and is forced downward through the replaceablefilter element (7). Air exits through the air outlets (8).

1-6

Page 12: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

e. Accessory Package. The accessory package contains all materials required to initiate and sustain operation ofSCPE. The accessory package is compact and man-portable. It is designed to support the SCPE and contains thefollowing:

(1) Repair Material. Used for extensive repairs of SCPE liners.

(2) Motor Blower. Provides air flow to inflate and continually purge liners and PE of contaminants. Providespower for extension light, recirculation filter, and PE dome light through the power supply located in thePE.

(3) Short Air Duct (5 ft long). Provides airflow from blower to HSFC, has adapters in both ends.

(4) Tape. Used to repair damaged liner, liner carrier bag, air duct hoses, and PE fabric.

(5) 220 VAC Cable Adapter. Provides capability to use power cable in 220 VAC (European type) powerreceptacles or with a generator.

(6) 110 VAC Cable Adapter. Provides capability to use power cable in 110 VAC power receptacles or with agenerator.

(7) Extension Light. Provides interior light to liner.

(8) AC Power Cable Assembly. Provides electrical link between motor blower and 110/220 VAC cableadapters.

(9) Accessory Case. Durable storage and carrying case for SCPE supplies and accessories.

(10) Long Air Duct (7 ft long). Provides airflow from HSFC through PE to sealed liner.

(11) Gaskets. On board spares used to repair air duct hose adapter and filter adapter. Consists of six filteradapter gaskets and three air duct hose adapter gaskets.

1-7

Page 13: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

1-9. LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (CONT).

f. ECU Adapters (AAL, App C). There are two types of ECU adapters; one for 18,000 BTU horizontal airconditioner (1) and one for 18,000 BTU vertical air conditioner (2). ECU adapters are packed in a carrier bag.

1-10. DIFFERENCES BETWEEN MODELS.

There is only one version of the M20A1 SCPE.

1-8

Page 14: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

1-11. EQUIPMENT DATA.

a Dimensions and Weights of SCPE Components

LENGTH WIDTH HEIGHT WEIGHTCOMPONENT

INCH CM INCH CM INCH CM LB KG

PE (Packaged) 48 121.92 41 104.14 9 22.86 74 33.3

Accessory Package 39 99.06 24 60.96 13 33.02 76 34.2

Room Liner Package 30 76.20 24 60.96 12 33.02 37 16.65

HSFC (Crated) 28 71.12 30 76.20 17 43.18 120 54.43

Recirculation Filter 17 43.18 17 43.18 27 68.58 40 18.0(Packaged)

ECU Adapter 31 78.74 21 53.34 1 2.54 10 4.5Package(AAL, App C)

b. Operating Power Requirements and Characteristics of SCPE.

POWER INPUT AIRFLOWCOMPONENT REQUIREMENTS VOLTAGE (CFM)

Motor Blower 1654 WATTS 110 or 220 VAC 50/60 Hz 200

Extension Light 100 WATTS 110 VAC NA

Dome Light 14 WATTS 110 VAC NA(28 VDC)

Recirculation Filter 300 WATTS 110 VAC NA

1-9

Page 15: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section III. PRINCIPLES OF OPERATION

1-12. SYSTEM DESCRIPTION.

a. To provide NBC protection, a higher pressure must exist inside the shelter than outside the shelter. The airflowthat causes the pressure must pass through the HSFC. Small leaks in the shelter liner will have no effect as long aspressure is maintained inside shelter.

b. When the system is pressurized, almost all airflow into shelter will flow through PE to the contaminated exterior.

c. The blower inflates the shelter to a pressure of 0.6 iwg. Vents between shelter and PE are adjusted for pressureof 0.6 iwg in shelter, and vents between PE and outside are adjusted for pressure of 0.25 iwg in PE. Clean air flowingfrom shelter to outside through PE purges toxic vapors from PE.

1-13. FUNCTIONAL DESCRIPTION OF MAJOR COMPONENTS.

a. Motor Blower. The blower provides a minimum of 200 cubic feet of air per minute to the protective shelterthrough the HSFC. It will operate on 110/220 VAC 50/60 Hz. Blower assembly provides electrical power for extensionlight and PE dome light through output connector J2 to the PE power supply.

b. Hermetically Sealed Filter Canister (!SFC). This filter removes toxic chemical agents, biological agents, andradioactive particles from air passing through it.

c. Air Ducts. The air ducts provide airflow path for air from blower through HSFC into shelter.

d. Recirculation Filter. The recirculation filter removes residual toxic agents which may be present inside theSCPE liners. The recirculation filter blower motor operates from any 115 VAC 50/60 Hz electrical source.

e. Room Liner. Room liners are cylindrical in shape and are inflated with filtered air from HSFC and blower.The inflated room liners provide a place to work or rest without having to wear protective clothing.

f. Protective Entrance (PE). PE allows personnel to move from contaminated area into liner without introducingcontaminants into protected area.

g. Differential Pressure Gages. There are two gages that read from 0 iwg to 2.0 iwg. One is mounted on linerside of PE and measures difference in pressure between inside liner and outside. Another is mounted to inside wall ofPE and measures difference in pressure between inside PE and outside. The gages are used when adjusting internalpressures in shelter and PE. An adjusting tool is provided to adjust gages before operation.

h. Vents Two vents near the bottom of the two outer PE walls are used to adjust PE pressure. Two vents near thetop of the liner side of PE wall are used to adjust shelter pressure. PE and shelter pressure can be regulated by adjustingthese vents.

i. Dome Light. There is one dome light mounted to the ceiling of the PE which operates at 28 VAC supplied byPE power supply.

j. Interval Timer. A mechanical five-minute bell timer is mounted on the wall of the PE. It is used to time thepurge period of personnel entering the SCPE from contaminated areas.

1-10

Page 16: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

CHAPTER 2OPERATING INSTRUCTIONS

Section I Description and Use of Operator's Controls and Indicators .................................................... 2-2

2-1 Motor Blower Assembly ......................................................................................................... 2-22-2 Protective Entrance ............................................................................................................... 2-32-3 Recirculation Filter ................................................................................................................ 2-4

Section II Preventive Maintenance Checks and Services (PMCS) ......................................................... 2-5

2-4 Introduction to PMCS Procedures ......................................................................................... 2-52-5 Operator Preventive Maintenance Checks and Services for M20A1 SCPE

Before ............................................................................................................................... 2-6During ............................................................................................................................... 2-15After 2-19

Section III Operation Under Usual Conditions ........................................................................................ 2-22

2-6 Initial Condition M20A1 SCPE ............................................................................................... 2-222-7 Initial Adjustments and Daily Checks ..................................................................................... 2-222-8 M20A1 SCPE Preparation and Assembly for Use .................................................................. 2-222-9 Operating Procedures ........................................................................................................... 2-442-10 Operation of Auxiliary Equipment .......................................................................................... 2-452-11 Preparation for Movement of M20A1 SCPE .......................................................................... 2-452-12 Operating Instructions on Decals and Plates ......................................................................... 261

Section IV Operation Under Unusual Conditions .................................................................................... 263

2-13 Joining Two or More M20A1 SCPE Units .............................................................................. 2-632-14 M20A1 SCPE Used in Area with High Ceilings ...................................................................... 2642-15 Installing M20AI Liners Without Pressurization ...................................................................... 2-662-16 Deploying M20AI SCPE in an NBC Environment .................................................................. 2-67

2-1

Page 17: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section I. DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS

2-1. MOTOR BLOWER ASSEMBLY

Key Control or Indicator Function or Use

1 Time Totalizing Meter Indicates total hours of blower operation.

2 Power Switch Two position toggle switch/circuit breaker controls power to blowers,extension light, and dome light. Switch is also a 20 amp circuitbreaker. To reset, turn switch down (off), then up (on).

2-2

Page 18: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-2. PROTECTIVE ENTRANCE

Key Control or Indicator Function or Use

1 Gages Indicates air pressure difference between outside and inside PE andinside shelter and outside.

Zero adjusting tool is used to turn adjusting screw either left or rightto align gage needle with zero.

2 Interval Timers Mechanical timer bell which monitors purge time. Personnel mustremain in PE until bell sounds.

2-3

Page 19: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section I. DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS (CONT)

243. RECIRCULATION FILTER.

KEY CONTROL OR INDICATOR FUNTION

1 Power Switch Two-position rocker switch controls power to internal blower motor.Press switch up (on) or down (off).

2-4

Page 20: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section II. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)

2-4. INTRODUCTION TO PMCS PROCEDURES.

a. General The Operator PMCS table has been provided so you can keep your equipment in good operatingcondition and ready for its primary mission. The PMCS table is arranged to provide procedures for checks and servicesto be performed before, during, and after operation of the equipment. The following paragraphs provide information onhow to use the PMCS table. If your equipment does not perform as required, refer to Chapter 3 under Troubleshootingfor possible problems and corrective actions to be taken. Report any malfunctions or failures on the proper DA Form2404, or refer to DA PAM 738-750.

b. Warnings and Cautions Always observe the warnings and cautions appearing in your PMCS table. Warningsand cautions appear before the applicable procedures. You must observe all warnings and cautions to prevent seriousinjury to yourself or others and to prevent damage to your equipment.

2-5. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE.

The following paragraphs describe the information presented in each column of the PMCS table.

a. Item Number Column. Numbers in this column are for reference. When completing DA Form 2404 (EquipmentInspection and Maintenance Worksheet), include the item number for the check/service indicating a fault. Item numbersalso appear in the order that you must do checks and services for the intervals listed.

b. Interval Column. This column tells you when you must do the procedure in the procedure column. BEFOREprocedures must be done before you operate or use the equipment for its intended mission. DURING procedures mustbe done during the time you are operating or using the equipment for its intended mission. AFTER procedures must bedone immediately after you have operated or used the equipment.

c. Item to Check/Service Column. This column identifies the item to be checked or serviced.

d. Procedure Column. This column gives the procedure you must do to check or service the item listed in theItem to Check/Service column to know if the equipment is ready or available for its intended mission or for operation.You must do the procedure at the time stated in the interval column.

e. Not Fully Mission Capable If: Column. Information in this column tells you what faults will keep yourequipment from being capable of performing its primary mission. If you make check and service procedures that showfaults listed in this column, do not operate the equipment. Follow standard operating procedures for maintaining theequipment or reporting equipment failure.

f. Other Table Entries. Be sure to observe all special information and notes that appear in your table.

2-5

Page 21: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20AI SCPE

NOTEIf the equipment must be kept in continuous operation, do only those procedures that can bedone without disturbing operation. Make complete checks and services when the equipment isshut down.

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

1 Before Room Liners a. Inspect room liners (1) for Two of the three line cannot bepunctures, tears, separated seams, repaired and can no longerworn hook-and-pile fasteners, maintain pressureand proper connections. Repairfabric if necessary (para 3-3).

b. Check to ensure room adapters Adapters are missing(2) are available with room liner.

c. Check room adapter for worn Hook-and-pile fasteners will nothook-and-pile fastener (for stay fastened.multiple unit liners only).

2-6

Page 22: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

2 Before PROTECTIVE a. Inspect PE fabric (1) for punc- Fabric is punctured or torn, windowsENTRANCE tures or tears, broken windows broken, vent flaps missing, seams

(2), missing vent flaps (3), separated, or hook-and-pile fasteners separated seams, or worn hook-will not stay closed.and-pile fasteners (4). Repairfabric if necessary (para 3-3).

b. Check for distorted, cracked, or . Frame will not erect properly.bent frame (5).

c. Check for broken or missing Frame legs cannot be locked intohinge pins (6) (three per leg). place.

d. Check that legs are locked and Frame legs will not lock together.knob (7) is present.

e. Check for broken or missing More than two link-lock fastenerslink-lock fasteners (8). are broken or missing.

2-7

Page 23: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

2 Before PROTECTIVE f. Inspect power supply (9) for Cracked or split wire, insulation orENTRANCE dents or cracks. Inspect both connector or miming connector or(CONT) power cords (10) for bare wire, missing connector pins.

cracked or split insulation orconnector on missing connectoror missing connector pins (11).

3 Before INTERVAL TIMER Check that interval timer (12) Interval timer is inoperative.operates. Turn knob (13) clock-wise back to zero (five minutes).Monitor to ensure timer isfunctioning properly and bellrings.

2-8

Page 24: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

4 Before GAGES a. Check gages (14) (located on Glass is broken, or tubing missingor

inside and outside wall of PE) for damaged.broken glass (15), and ensure thattube (16) is connected.

b. Check that gages adjust to zero as Gage(s) will not adjust.follows:(1) Insert zero adjusting tool (17)in adjusting screw (18).(2) Turn adjusting tool (17) rightto raise or left to lower tozero.

5 Before HSFC NOTE

It is vital that the HSFC for SCPE be fully serviceable. As anoperator you are responsible for notifying unit maintenance forreplacement in accordance with filter change criteria containedin FM 3-4.

Inspect HSFC (1), especially seams HSFC is dented, seam cracked or(2), for cracks, dents, or holes. dented deeper than 1/4 inch, or hasCheck for water damage around holes. Tab pull damaged.the tab pull.

2-9

Page 25: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20AI SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

7 Before ACCESSORY a. Check for missing components. Components missing.PACKAGE Each kit should have:

(1) Repair material(2) Motor blower assembly(3) Short air duct(4) Tape(5) 220 VAC cable adapter(6) 110 VAC cable adapter(7) Extension light

b. Check 220 VAC cable adapter Cable adapters or power cable have(5), 110 VAC cable adapter (6), bare wires, cracked or splitinsulationand power cable (8) for bare wires, or connectors, or bent, broken orcracked or split insulation or missing connector pins or sockets.connectors, and bent, broken, ormissing connector pins or sockets.

2-10

Page 26: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

7 Before MOTOR BLOWER a. Check for cracks, broken, or Housing is cracked, broken, ordistorted housing (1). distorted.

b. Check air outlet flange (2) for bent Air duct cannot be connected tomotor

pins or missing pins (3) and miss- blower assembly.ing electronic component shield(4).

c. Check electrical connectors (5) Any pins are missing or electricalfor cracks, dents, bent or missing cables cannot be connected tomotorpins, or missing electrical connec- blower.tor covers (6).

d. Check time totalizing meter (7) to Totalizing meter indicates 500 hourssee if 500 hours have passed since have elapsed since last motorlast blower motor replacement. replacement.

2-11

Page 27: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

8 Before AIR DUCTS a. Check air duct hoses (1) for Air duct hoses punctured, torn orpunctures, tears, or protruding have protruding wires.wires at end of duct. Repair hoseif necessary (para 3-3).

b. Check for damaged or missing Adapter, clamp, or gaskets missingadapters (2), hose clamps (3), and ` or damaged.gaskets (4).

9 Before EXTENSION a. Check light (1) for cracked or Extension light has bare wires, broken

LIGHT bare wires (2), missing screw on insulation, prongs missing, connector

connector (3), cracked connector cracked, or screws missing.(3), or missing or bent prongson connector (3).

b. Check that lamp (4) is operating. Lamp inoperative.

2-12

Page 28: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

10 Before RECIRCULATION NOTEFILTER

It is vital that recirculation filter for SCPE be fully serviceable. Asan operator you are responsible for notifying unit maintenance forreplacement in accordance with filter change criteria contained inFM 34.

a. Check electrical cable (1) for bare Cable has bare wires or brokenwires or broken connector (2) or connector.missing connector or missingconnector pins (3).

b. Check cover (4), lower case (5), Cover, case, or fan impeller bladefan impeller blade (6),and guard damage prevents normal operation.(9) for damage.

c. Check that filter (7) is present. Filter is missing.

d. Remove cover by releasing four Filter has punctures or is waterlink-lock fasteners (8) and pull damaged.filter up and check for puncturesor water damage.

2-13

Page 29: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

11 During ROOM LINERS Inspect room liners (1) and adapters Liner(s), including tape repairs, can(2) for punctures, tears, separated no longer maintain pressure or

hook-seams, worn book-and-pile fasteners, and-pile fasteners will not stayand proper connections. Repair fastened.fabric if necessary (para 3-3).

2-14

Page 30: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

12 During PROTECTIVE Inspect PE fabric (1) for punctures PE fabric, including tape repairs noENTRANCE or tears, broken windows (2), missing l longer maintain pressure or hook-

and-vent flaps (3), separated seams, or pile fasteners will not stay fastened.worn hook-and -pile fasteners (4).Repair fabric if necessary (para 3-3).

13 During DOME LIGHT Check that dome light (1) is on. Dome light is inoperative and noother light source is available.

14 During INTERVAL Check that interval timer (2) Interval timer is inoperative.TIMER operates. Turn knob (3) clockwise

back to zero (five minutes). Monitorto ensure timer is functioning properlyand bell rings.

2-15

Page 31: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

15 During GAGES a. Check gages (1) (located on inside Glass is broken, tubing is missing.and outside wall of PE) for brokenglass (2), and tube (3) is missing.

b. Check that pressure reading in PE Pressure is below 0.2 iwg in PE oris not below 0.2 iwg. below 0.4 iwg in liner.

c. Check that pressure reading inliner is not below 6.4 iwg.

16 During MOTOR BLOWER a. Check for noisy operation. Operating noise level is unusual.

b. Ensure time totalizing meter (1) Time totalizing meter is inoperative.is operating.

2-16

Page 32: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

17 During EXTENSION Check that lamp (1) is operating. Light inoperative.LIGHT

18 During RECIRCULATION NOTEFILTER

It is vital that recirculation filter for SCPE be fully serviceable. Asan operator you are responsible for notifying unit maintenance forfilter replacement in accordance with filter change criteriacontainedin FM 34.

Check recirculation filter (1) for Operating noise level is unusual.noisy operation.

2-17

Page 33: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20A1 SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

19 After ROOM LINER a. Check to ensure room adapter (2) Room adapter is missing.is available with room liner.

b. Check for worn hook-and-pile Hook-and-pile fasteners will not stayfasteners. fastened.

20 After PROTECTIVE Check for broken or missing link- More than two link-lock fasteners are

ENTRANCE lock fasteners (1). broken or missing.

2-18

Page 34: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

21 After HSFC NOTE

It is vital that the HSFC for SCPE be fully serviceable. As anoperator you are responsible for notifying unit maintenancefor HSFC replacement in accordance with filter change criteriacontained in FM 3-4.

Inspect HSFC (1), especially seams HSFC is dented, seams cracked or(2), for cracks, dents, or holes. dented deeper than 1/4 inch, or hasCheck for water damage. holes. HSFC water damaged.

22 After ACCESSORY Check for missing components. Each Components missing.PACKAGE package should have:

(1) Repair material(2) Motor blower assembly(3) Short air duct(4) Tape(5) 220 VAC cable adapter(6) 110 VAC cable adapter(7) Extension light(8) Power cable assembly

2-19

Page 35: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR M20AI SCPE (CONT)

Item Interval Item To Be Procedure Not Fully MissionNo. Check/Service Capable If:

23 After MOTOR BLOWER Check time totalizing meter (I) to see Totalizing meter indicates 550 hoursif 550 hours have passed since last have elapsed since last motor

replace-blower motor replacement. ment.

24 After RECIRCULATION NOTEFILTER

It is vital that recirculation filter for SCPE be fully serviceable.As an operator you are responsible for notifying unit maintenancefor filter replacement in accordance with filter change criteriacontained in FM 3-4.

a. Check electrical cable (1) for bare Cable has bare wires or brokenwires or broken connector (2) or connector or missing connector ormissing connector or missing missing connector pins.connector pins (3).

b. Check cover (4), lower case (5), Cover, case, or fan impeller bladefan impeller blades (6), and guard damage prevents normal operation.(7) for damage.

2-20

Page 36: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section III. OPERATION UNDER USUAL CONDITIONS

2-6. INITIAL CONDITION M20AI SCPE.

a. Site Selection. Consider the following conditions when selecting a structure to house an M20A1 SCPE.

NOTEEntire M20A SCPE must be deployed indoors.

(1) Location serves tactical situations.

(2) Location shielded from weapons or blast.

(3) Location away from low areas where chemical vapors tend to collect.

b. Room Selection.

(1) The M20A1 SCPE should be deployed in a room with four walls, a floor and a ceiling, all in goodcondition.

(2) Electrical power available within 25 ft. of chosen room and have at least a 15 Amp circuit breaker.

2-7. INITIAL ADJUSTMENT AND DAILY CHECKS.

Perform before PMCS (para 2-5).

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE.

a. Preparation.

CAUTIONHot radiators, heaters, and lights in selected room may damage room liner.

(1) Turn off radiator, heaters, and lights in selected room.

WARNINGThree major components of M20AI SCPE weigh approximately 100 pounds each. Lifting and/orcarrying can be accomplished by no fewer than two personnel. Failure to do so can result insevere injury to personnel.

(2) Carry components of M20Al SCPE (requires two personnel) into selected structure. Place componentsnear door of selected room.

CAUTIONDebris on floor of selected room may damage room liner.

2-21

Page 37: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(3) Remove furnishings and debris which will interfere with deployment of SCPE.

NOTE

If selected room has windows, refer to your unit Standing Operating Procedures (SOP) or yoursupervisor for blackout procedure before continuing.

Wipe dusty surfaces with dry rag (Item10, App D) before applying tape.

(4) Using tape from accessory package, seal windows, pad sharp objects and overhead lights.

b. M20A1 Room Liner Installation.

(1) Open room liner carrier bag (1) and remove room liner (2).

(2) Carry room liner (2) into prepared room. Place room liner with loop ties facing up. Carefully unfold andspread liner on floor.

2-22

Page 38: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20AI SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

(3) Position room liner so it will mate with PE through doorway. If doorway cannot be used, and room is largeenough, both room liner and PE can be deployed inside prepared room.

CAUTIONAvoid walking near edges of room liner floor. Furniture, equipment, or personnel can punctureliner if positioned where weight is placed on outer boundary of room liner floor.

NOTETwo personnel must hold top of room liner opening high to allow entry. Furniture or equipmentis placed as close to center of room liner as possible.

(4) Place furniture or equipment in room liner (2).

(5) Remove extension light (3) from accessory package and place on floor inside room liner (2).

(6) Place recirculation filter blower (1) on floor inside room liner (2) where it will not interfere with personnelmovement.

2-23

Page 39: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

c. Installing Protective Entrance (PE).

WARNING

PE weighs approximately 74 lbs. At least two personnel are required to carry and erect PE toprevent injury to personnel.

(1) Place PE (1) near the room liner entrance, where it will be used.

(2) Unlock link-lock fasteners (2) on three sides of PE (1).

(3) Ensure locking bar (3) on each PE leg (4) is in unlocked position.

2-24

Page 40: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

WARNING

Improper lifting of PE top when erecting may cause back strain to personnel. To avoid backstrain, follow proper lifting procedures.

NOTETwo personnel are required to lift PE.

(4) To avoid back strain, lift PE top as follows:

(a) Squat down with knees bent and back straight.

(b) Grasp handles (5).

(c) Keep back straight and use your legs to left PE top (6).

WARNINGKeep hands clear of leg hinges when erecting PE. Pinching hands or skin in hinged joints cancause serious injury.

(5) At chest height, while holding handle (5) firmly, slip one hand to underside of PE top (6). Holding top upfrom below, move other hand to underside of PE top.

2-25

Page 41: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(6) Push top (6) up as high as possible. While holding top (6) up with one hand, firmly grasp one PE leg (4)with other hand.

(7) While firmly holding PE leg (4) with one hand, move other hand to opposite leg and pivot both legs to astraight position.

(8) Push locking device (7) on each leg (4) in and down to lock.

(9) Using attached zero adjusting tool (8), adjust gage (9), on outside PE wall, to zero.

(10) Using attached zero adjusting tool (8), adjust gage (10), on inside PE wall, to zero.

(11) Position PE next to PE airlock adapter.

(12) Pass power cord (11) from inside PE through cable sleeve (12) and duct sleeve (13).

(13) Tighten cable sleeve.

2-26

Page 42: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

d. Attaching Room Liner to PE.

(1) If passage from PE to room liner is through an existing doorway, position PE so flange (1) extends intodoorway (2).

NOTE

Attaching room liner to PE requires two personnel.

Mate hook-and-pile fasteners as smoothly as possible to avoid excess air leakage from roomliner.

(2) Lift top of room liner (3) opening over your head and step inside room liner. Aline top of room liner withtop of PE flange (1).

2-27

Page 43: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(3) Second person enters room liner, attaches room liner (3) to PE flange (1) by first attaching top corners,then working hook-and-pile fasteners (4) toward center. Pinch off any excess material at center.

(4) Attach bottom two corners and work hook-and-pile fasteners (4) toward center. Pinch off excess materialat bottom center.

(5) Working from corners, join hook-and-pile fasteners (4) along the sides. Pinch off any excess material atcenters.

e. Assembling Motor Blower and HSFC.

CAUTIONDo not drop the hermetically sealed filter canister (HSFC). Dropping could cause broken seals.

(1) Place crated HSFC (1) as close to PE (2) as possible and in vicinity of power source (3).

2-28

Page 44: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

WARNINGDo not locate motor blower near an area where exhaust gasses are generated because HSFC willnot remove carbon monoxide. Breathing carbon monoxide gasses can cause serious illness ordeath to personnel inside SCPE.

(2) Remove motor blower (4) from accessory package (5) and place it beside crated HSFC (1).

2-29

Page 45: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(3) Remove long air duct (6) (has one adapter) from accessory package.

(4) Feed end without adapter through duct sleeve (7) on PE fange (8).

(5) Fasten hook-and-pile strap (9) around air duct.

(6) Secure duct sleeve strap (10) around duct sleeve (7).

(7) Tie off unused duct sleeve.

2-30

Page 46: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

(8) Open lid of crate containing HSFC (1) as follows:

(a) Unfold wire loops (11) holding lid (12) closed and fold lid back.

(b) Remove foam cover (13) from crate. Set foam cover aside for re-use.

WARNINGSharp edges on the HSFC can cause injury to personnel. Use care when connecting ordisconnecting air ducts to HSFC.

NOTEOdor of ammonia is common when HSFC is first opened. Odor will soon disappear and is notharmful to personnel.

(9) Remove outlet (outer) port pull-tab lid (14) from HSFC (1).

(10) Connect adapter end of long air duct (6) to outlet port (15) by pushing spring button (16) in.

(11) Insert adapter in outlet port (15) by pushing in spring button (16).

2-31

Page 47: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(12) Remove short air duct (17) from accessory package and attach to output of motor blower as follows:

(a) Aline slots in adapter (18) with pins in motor blower outlet port (19). Push adapter in.

(b) Rotate adapter clockwise to lock in place.

(13) Remove inlet center port pull-tab lid (20) from HSFC (1).

(14) Connect other end of short air duct (17) to inlet port (21) of HSFC.

(15) Remove any kinks or bends in air ducts by moving components.

2-32

Page 48: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

WARNINGTo prevent electrical shock, ensure motor blower power switch is in off (down) position beforeconnecting or disconnecting power cable.

(16) Remove power cable (22) from accessory package.

(17) Remove connector covers (23) from motor blower (24) connectors J1 (25) and J2 (26).

(18) Connect power cable (22) connector P2 to input connector Jl (25) of motor blower (24).

(19) Connect power cable (22) connector P1 to either the 110 VAC cable adapter (27) or 220 VAC cableadapter (28) depending on power source available.

(20) Connect PE power supply power cord (29) and connect to output connector J2 (26).

(21) Connect cable adapter (27 or 28) to power source.

2-33

Page 49: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

f. Installing Recirculation Filter.

(1) Check that recirculation filter power switch (1) is in down (off) position.

(2) Place recirculation filter inside room liner where it will not interfere with personnel movement or restrictairflow.

CAUTIONTo avoid overloading motor blower, do not plug more than one recirculation filter blower into PEpower supply.

(3) Plug recirculation filter power cord (2) into PE power supply.

g. Inflating Room Liner.

(1) Close all vents (1) on PE.

2-34

Page 50: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

WARNINGMotor blower operating noise may be hazardous to operator hearing. Hearing protection must beworn when remaining within 4 feet of motor blower in operation. Failure to wear hearingprotection can result in hearing loss.

NOTEWalking into and out of SCPE liner should be kept to a minimum so liner can inflate quickly.

(2) Turn motor blower power switch (2) to the up (on) position.

(3) As room liner begins to inflate, enter room liner (one person only). Before room liner is fully inflated,attach extension light (4) to room liner ceiling, using hook-and-pile fasteners (5). Smooth out room linermaterial and remove wrinkles from floor and walls. Watch room liner as it inflates, making sure that itdoes not snag on any objects within room.

2-35

Page 51: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(4) Pass plug end of extension light cord (6) through PE cable sleeve (7).

(5) Insert plug into outlet on power supply (8).

(6) Secure cable sleeve (7) around extension light cord (6).

NOTETo conserve filter life, do not turn on recirculating filter until room liner is inflated.

(7) Turn recirculation filter power switch to the up (on) position.

h. Adjusting Internal Pressures.

NOTETwo personnel are required to adjust internal pressures of PE and room liner, one in PE andother in liner.

Opening vents from liner to PE will reduce the pressure in liner and increase pressure in PE.Opening vents from PE to outside will reduce pressure in PE.

Change only one vent at a time. Wait at least 10 seconds between changes to allow pressures tostabalize.

Maximum allowable operating pressure in liner is 1.20 iwg; minimum allowable operatingpressure in liner is 0.6 iwg.

2-36

Page 52: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

(1) Set one interior vent (1) and one exterior vent (2) to half open (others are closed). From inside liner,monitor internal gage (3).

(2) Allow liner pressure to build up to 1.20 iwg (close interior vents (1) as necessary).

(3) After liner pressure has stabilized between 0.6 and 1.20 iwg, as indicated on PE internal gage (3), adjustexterior vents (2), as required to maintain the pressure between 0.2 and 0.3 iwg in PE. From inside PE,monitor external gage (4).

2-37

Page 53: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

i. Installing Horizontal ECU Adapter (AAL, App C).

(1) Loosen four 1/4 turn fasteners (1) from ECU adapter frame (2).

(2) Separate inner ECU adapter frame (2) from outer ECU adapter frame (3).

(3) Using screwdriver (Item 11, App D), remove screws (4) from front of ECU duct (5) and remove ECU duct(5).

(4) Place ECU adapter duct (6) around ECU duct (5).

(5) Using screwdriver (item 11, App D), install ECU duct (5) on ECU (7).

(6) Place ECU (7) next to room liner (8) exterior to determine the position ECU adapter will be installed onroom liner.

(7) From outside room liner (8), have person hold outer ECU adapter frame (3) against room liner (8) atposition determined in step 6.

2-38

Page 54: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

(8) From inside room liner (8) have another person aline inner ECU adapter frame (2) with outer frame.

(9) From inside room liner (8) tighten four 1/4 turn fasteners (1) through inner ECU adapter frame (2), roomliner (8), and outer ECU adapter frame (3).

(10) Using pocket knife (Item 6, App D) cut room liner material (8) from inside ECU adapter frame (2).

(11) Feed ECU power cord (9) through ECU adapter duct sleeve (10) and secure duct sleeve around ECUpower cord (9).

2-39

Page 55: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

WARNINGDo not operate ECU with ECU make up air ports open. System will become contaminated whichcan result in serious illness, injury, or death to personnel.

(12) Close ECU make up air ports (11).

(13) Operate ECU in accordance with TM 5-4120-379-14.

j. Installing Vertical ECU Adapter.

(1) Loosen four 1/4 turn fasteners (1) on both vertical ECU adapter frames (2).

(2) Separate inner ECU adapter frames (3) from outer ECU adapter frames (2).

2-40

Page 56: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-8. M20A1 SCPE PREPARATION AND ASSEMBLY FOR USE (CONT).

(3) Using screwdriver (Item 11, App D), loosen screws (4) from front of ECU ducts (5) and remove ECU ducts(5).

(4) Place ECU adapter ducts (6) around ECU ducts (5).

(5) Using screwdriver (Item 11, App D), install ECU ducts (5) on ECU (7).

(6) Place ECU (7) next to room liner (8) exterior to determine the position ECU adapter will be installed toroom liner.

(7) From outside room liner (8) have person hold inner ECU adapter frames (3) against room liner (8) atposition determined in step 6.

2-41

Page 57: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(8) From inside room liner (8) have another person aline outer ECU adapter frames (2) with inner frames (3).

(9) From inside room liner (8) tighten four 1/4 turn fasteners (1) on each interface frame through outer ECUadapter frames (2), room liner (8), and inner ECU adapter frames (3).

(10) Using pocket knife (Item 6, App D) cut room liner material (8) from inside both ECU adapter frames (2).

WARNINGDo not operate ECU with ECU make up air ports open. System will become contaminated whichcan result in serious illness, injury, or death to personnel.

(11) Close ECU make up air ports.

(12) Operate ECU in accordance with TM 5-4120-379-14.

2-42

Page 58: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-9. OPERATING PROCEDURES.

a. General.

(1) Personnel entering SCPE shall follow entry procedures in FM 3-4 and unit SOP when chemical orbiological contamination of protective clothing or personal equipment is known or suspected.

(2) When SCPE is deployed in a toxic environment, it may take up to 1-1/2 hours to purge liner of toxic vaporsfrom time motor blower is turned on.

(3) Make sure motor blower and recirculation filter are on and operating.

b. PE Entry Procedure.

WARNINGPersonnel who enter SCPE must wear clean, uncontaminated protective mask and clothing.Failure to wear uncontaminated protective mask and clothing can result in further contaminationof personnel. Contact with biological or chemical agents can result in serious illness, injury, ordeath.

WARNINGDo not take equipment into interior of SCPE unless you are certain that it has never becomecontaminated or that it has been thoroughly decontaminated. This includes your weapon.

NOTEOnly one person may enter PE at a time.

(1) Before entering PE, look through PE window to ensure PE is unoccupied.

(2) Enter PE and ensure door is closed and hook-and-pile fasteners are sealed. Set interval timer, mountedon PE inside wall, by turning knob fully clockwise to 5 minutes.

(3) If interval timer does not sound or knob does not return to zero, reset timer to five minutes (use a watch orcount aloud if necessary).

(4) After interval timer bell sounds, enter liner in accordance with procedures outlined in FM 34.

2-43

Page 59: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

c. PE Exit Procedures.

NOTEFor guidance on exit procedures, see FM 34 and unit SOP.

(1) Exit protective area as follows:

(a) Look through PE window to ensure PE is unoccupied and interval timer is set at zero. This showsthat the PE has not been occupied and no wait is necessary before entering the PE. Otherwise, waituntil the interval timer bell sounds (about five minutes) before exiting.

(b) Turn interval timer knob to zero (5 minutes). This is to let anyone still inside shelter know when 5-minute purge time is over.

(2) Exit PE in accordance with FM 3-4 and unit SOP.

2-10. OPERATION OF AUXILIARY EQUIPMENT.

WARNINGLocate generator outside structure or in well ventilated area. Do not locate motor blower near anarea where engine exhaust gasses are generated. Filter will not protect against carbonmonoxide. Carbon monoxide poisoning can cause illness, incapacitation, or death to personnel.

a. The SCPE can be operated from a portable generator (App C) when commercial electric power is not available.Refer to TM 5-6115-323-14 for operation of portable generator.

b. Observe the following precautions:

(1) Place portable generator outside building if possible.

(2) If portable generator must be inside structure, place at maximum power cable length from blower.

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE.

WARNINGSCPE known to be or suspected of biological or chemical agent contamination, must bedecontaminated before striking.

Protective mask and clothing must be worn by personnel handling contaminated components ofSCPE.

2-44

Page 60: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

a. Decontaminating SCPE.

NOTEProcedures for disposal of contaminated liners and HSFC are in unit SOP and FM 34, NBCProtection.

Decontaminate all components except liner (see FM 3-5, NBC Decontamination).

b. Striking SCPE.

NOTEDisassemble SCPE in sequence described in the following procedures. Stow accessory packageitems in marked slots.

(1) Disconnect motor blower as follows:

WARNINGEnsure motor blower power switch is in down (off) position before connecting or disconnectingpower cable.

(a) Set power switch (1) to down (off) position.

(b) Disconnect 110/220 VAC cable adapter (2) from power source.

(c) Disconnect power cable (3) from motor blower.

(d) Disconnect cable adapter (2) from power cable (3).

(e) Stow power cable and cable adapter in accessory package.

(f) Disconnect electric power cord (4) from motor blower. Coil power cord and store on floor of PE.

(g) Attach connector covers (5).

(h) Disconnect short air duct (6) from motor blower by turning counter-clockwise.

(i) Store motor blower in accessory package.

2-45

Page 61: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(2) Remove and store extension light as follows:

(a) Unplug extension light plug (1) from power supply (2) in PE.

(b) Disconnect hook-and-pile fastener on cable sleeve.

(c) Pull plug (1) of extension light (3) into liner.

(d) Remove extension light (3).

(e) Wrap cord in a roll.

(f) Stow extension light in accessory package.

(3) Remove and store air ducts as follows:

NOTEWhen storing air ducts in accessory package, put one end of air duct in correct slot and carefullypush rest of air duct in.

(a) Depress spring button (1) on short air duct (2), tilt upward, and remove from HSFC (3).

(b) Store short air duct (2) in accessory package.

2-46

Page 62: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

(c) Open hook-and-pile fasteners straps (4) to disconnect long air duct (5) from PE and pull air ductthrough duct sleeve to outside.

(d) Depress spring button on long air duct (5), tilt upward, and remove from HSFC (3).

(e) Store long air duct (5) in accessory package.

(4) Crate HSFC as follows:

(a) Replace foam cover (1) on top of HSFC (2).

(b) Close lid (3) of HSFC crate.

(c) Fold wire loops (4) to secure lid.

2-47

Page 63: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(5) Inventory and close accessory package as follows:

(a) Check that components are present (para 2-5).

(b) Close cover (1) and secure three link-lock fasteners (2).

(6) Strike Protective Entrance (PE) as follows:

(a) Disconnect room liner (1) from PE flange (2).

(b) Close all vents (3) on PE.

2-48

Page 64: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

(c) Unplug recirculation filter power cord (1) from PE power supply (2).

(d) Remove recirculation filter power cord from PE through cable sleeve (3).

WARNINGAvoid pinching skin or protective garments in hinge joints to prevent injury or contamination.

CAUTIONDo not allow PE to collapse suddenly. Allowing PE to collapse could damage frame and fabric.

2-49

Page 65: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

NOTEStriking PE requires at least two personnel. PE may be moved to open area for easier handling.

(e) Hold PE top up firmly with one hand. Push knob (4) on leg (5) in and up to unlock each leg.

2-50

Page 66: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

(f) While still holding top with one hand, firmly grab one leg (6); push or pull to start folding action. Carefullyswitch hands and repeat for third leg.

(g) Using both hands, carefully lower PE top about halfway down.

(h) Slowly lower top as you bend one knee, letting top (7) rest on other knee. Place knee at center to balancePE top.

(i) While holding top of PE on your knee, tuck fabric (8) in beyond legs so when PE is closed, legs will notpinch fabric. Ensure handles on link-lock fasteners do not catch between halves when lowering PE.

2-51

Page 67: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(j) Grab handles (9) on top and slowly close PE. Ensure fabric does not interfere with closing, Check thatfabric is not pinched in legs or top and bottom before continuing.

(k) Lock link-lock fasteners on all three sides of PE as follows:

(1) Pivot fastener (10) up to meet mating part

(2) Turn handle (11) clockwise until completely locked

WARNINGTo avoid back strain, keep your back straight and use your leg muscles to lift the PE.

NOTELifting and moving the PE requires two personnel.

(1) To lift the PE 4 feet or higher from the ground, squat down (with knees bent and back straight), grasp ahandle (15) with one hand and place the other hand under the PE. As you begin to lift, use your knee tohold some of the PE weight while moving your hand from the handle to the bottom of the PE.

NOTEMake certain you have a firm grip on the PE before lifting higher.

2-52

Page 68: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20AI SCPE (CONT).

(7) Remove recirculation filter as follows:

(a) Coil recirculation filter power cord (1).

(b) Remove recirculation filter (2) from room liner.

(8) Horizontal ECU Adapter.

(a) Disconnect ECU power cord (1) from power source.

(b) Untie ECU adapter duct sleeve (2) and pull ECU power cord (1) through ECU adapter duct sleeve(2).

(c) Loosen four 1/4 turn fasteners (3) and remove outer ECU adapter frame (4).

(d) Move ECU away from liner.

2-532-53

Page 69: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

NOTELeave ECU adapter attached if it will be required during next mission.

(e) Using screwdriver (Item 11, App D), remove ECU duct (5) from ECU (6).

(f) Remove ECU adapter duct (7) from ECU duct (5).

(g) Using screwdriver (Item 11, App D), install ECU duct on ECU.

(h) Aline outer ECU adapter frame (4) with inner ECU adapter frame (8).

(i) Tighten four 1/4 turn fasteners (3).

2-54

Page 70: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

(j) Place ECU interface in carrier bag (9) and close.

(9) Vertical ECU adapters.

(a) Disconnect ECU power cord (1) from power source.

(b) Loosen four 1/4 turn fasteners (2) on each outer ECU frame (3) and remove frames.

(c) Move ECU away from liner.

2-55

Page 71: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

NOTELeave ECU adapter attached if it will be required during next mission.

(d) Using screwdriver (Item 11, App D), loosen screws from front of ECU ducts (4) and remove ECU ducts.

(e) Remove ECU adapter ducts (5) from ECU ducts (4).

(f) Using screwdriver (Item 11, App D), install ECU ducts (4) to ECU (6).

(g) Aline outer ECU frames (3) with inner ECU adapter frames (7).

(h) Tighten four 1/4 turn fasteners (2) on each ECU adapter frame.

2-56

Page 72: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

(i) Place ECU adapter in carrier bag (8) and close.

(10) Room Liner, M20A1 SCPE.

NOTEIf room liner has been contaminated, refer to your unit SOP, or NBC NCO for disposalinstructions.

If lumber and nails were used during unusual installation procedures, liner is not to be reused.

Dispose of room liner in accordance with unit SOP.

Extension light from accessory package may be used to provide lighting.

Two additional personnel will be required to hold liner opening open to remove furniture andequipment.

(a) Remove all equipment and furniture.

NOTEFolding room liner requires two personnel.

2-57

Page 73: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

(b) Locate circular floor seam at bottom of opening.

(c) Straighten circular seam to form smooth circle.

(d) Locate top circular seam (above top liner opening).

(e) Place top seam directly on top of bottom seam. Tuck liner sides inward to form a circle (1).

(f) Fold a 13 in. width of only top layer toward center to expose liner opening (2).

(g) With liner opening at center, fold left side of liner (top and bottom together), in 2-ft. wide folds, until foldsreach center line. Force air out after each fold.

2-58

Page 74: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-11. PREPARATION FOR MOVEMENT OF M20A1 SCPE (CONT).

(h) Repeat step (g) for right side. There should be about 3 to 6 in. gap between sides.

(i) Fold one side onto other. Force air out toward liner opening.

(j) Fold lengthwise into quarters. Force air out towards liner opening.

(k) Place folded liner into liner bag and reseal.

2-59

Page 75: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-12. OPERATING INSTRUCTIONS ON DECALS AND INSTRUCTION PLATES.

Motor Blower and HSFC

ERECTION OF PROTECTIVE ENTRANCE

1. UNLOCK LATCHES ALL 3 SIDES.2. GRASP HANDLES AND LIFT.3. FULLY EXTEND LEGS INTO POSITION.4. PUSH IN AND DOWN ON LOCKING KNOBS

TO LOCK EACH LEG IN PLACE.5. ATTACH PROTECTIVE ENTRANCE TO

LINER.6. SEE OPERATOR'S MANUAL

DECONTAMINATE PRIOR TO ENTRY.DO NOT REMOVE MASK UNTIL ENTRY PURGE IS

COMPLETE.NO COMBUSTION HEATERS INSIDE PROTECTED

AREA.SEE OPERATOR'S MANUAL

Protective Entrance

2-60

Page 76: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-12. OPERATING INSTRUCTIONS ON DECALS AND INSTRUCTION PLATES (CONT).

Protective Entrance

2-61

Page 77: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section IV. OPERATION UNDER UNUSUAL CONDITIONS

2-13. JOINING TWO OR MORE M20A1 SCPE UNITS.

WARNINGThis procedure should be done only in an uncontaminated environment.

NOTEIf shelter of more than 200 square feet of floor space is needed, two or more complete SCPEsystems can be joined using these procedures.

a. Set up and inflate one complete M20A1 SCPE system (para 2-8).

b. Select an unused door frame (1) on primary room liner (2). Door will be framed by pile fastener.

c. Using hook-and-pile fastener, attach room adapter (3) to door frame.

d. Unfold additional room liner (4) with door opening (5) facing primary room liner door frame (6).

e. Place equipment and furniture in additional room liner as required.

f. Attach additional room liner door opening (5) to room adapter (3) using hook-and-pile fastener.

g. From inside primary room liner, use knife (Item 6, App D) to cut out door opening (7) leaving a one inch borderinside hook-and-pile frame. As liner is being cut, air from primary room liner will inflate additional room liner.

h. Using hook-and-pile fastener, attach room adapter corner flaps (8), located at each corner of adapter, to insidecorners of primary (2) and additional room liner (4).

2-62

Page 78: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-14. M20A1 SCPE USED IN AREA WITH HIGH CEILINGS.

a. General.

NOTEPressure inside SCPE must be adjusted (para 2-8h) before reaching between 0.6 1.20 iwg.

If liner of SCPE is inflated in areas where ceiling height is greater than liner height, some loss of usable floorarea will occur as liner tends to assume a ball shape. Where a ceiling is higher than 12 ft., or where there is a falseceiling which will not bear the upward force of liner (about 600 lbs), there are two methods for maintaining liner shape.

b. Sandbagging.

(1) Ensure all vents from PE to shelter are open.

NOTEYou will need 12 to 14 sandbags, depending on weight of each bag. When room liner pressure is0.6 iwg, you will need 600 lbs of sandbags.

(2) Place sandbags (1) (Item 2, App D) inside liner.

(3) Place sandbags evenly along outer edge of floor.

(4) Adjust vents to proper pressures (para 2-8).

2-63

Page 79: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

c. Nailing.

CAUTIONCheck pressure inside SCPE to be sure it does not exceed 1.20 iwg during and after nailing.Overpressure will pull out nails and cause the material to tear.

NOTEMake sure that all vents from PE to shelter are fully opened. If liner is to be erected on a woodenfloor, it can be held down by nailing strips of wood to floor through liner.

(1) Place 12 strips of wood (1) (Item 8, App D), each 3 to 4 ft. long, evenly around perimeter of liner floor.

(2) While inflating room liner, use hammer (Item 5, App D) to drive three or four nails (Item 9, App D) througheach strip through room liner floor, and into room flooring. Be sure to nail wood strips on or near floorseam of room liner.

(3) Adjust vents to proper pressure (para 2-8).

2-64

Page 80: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-15. INSTALLING M20A1 SCPE LINERS WITHOUT PRESSURIZATION.

WARNINGThis procedure should be done only in a clean environment. Contamination of personnel bybiological or chemical agents can cause serious injury, illness or, death.

NOTEIf room liner is going to be unpressurized for any reason while occupied, use the following stepsto support the liner.

a. Attach support lines (1) across center of room in a cross or "X' pattern at a height of approximately 7 to 10 feet.

b. If only one support line (Item 7, App D) is used, run it from door opening to opposite side of room.

c. Secure all support lines (1) to room walls by any means available.

d. Aline room liner door (2) with room door (3).

e. Attach liner, center row of ties (4), to passive support line (1) going from door opening (3) to opposite side ofroom.

f. Attach remaining liner ties (5) to additional support lines (1).

2-65

Page 81: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

2-16. DEPLOYING M20A1 SCPE IN AN NBC ENVIRONMENT.

WARNINGFailure to comply with the following steps when installing the M20A1 SCPE in an NBCenvironment can result in contamination of personnel by biological or chemical agents andcause serious injury, illness, or death.

CAUTIONDS2 should not be used to decontaminate the liner. This may cause damage to the liner.

NOTEInstall the M20A1 SCPE (par 2-8) strictly adhering to the following additional steps.

a. Decontaminate all contaminated personnel and equipment in accordance with FM 3-5 and unit SOP.

b. Liner may be inflated without exterior ties and support lines.

c. Equipment must be carried in prior to liner inflation.

d. Using the M256AI kit (App D, item 4), ensure liner is completely purged of all contaminants prior to unmasking.

e. Turn on recirculation filter.

2-66

Page 82: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

CHAPTER 3MAINTENANCE INSTRUCTIONS

Section I. LUBRICATION INSTRUCTIONS

3-1. LUBRICATION.

The M20A1 SCPE requires no lubrication.

Section II. TROUBLESHOOTING

3-2. INTRODUCTION.

a. The troubleshooting table lists common malfunctions which you may find during the operation of the SCPE or itscomponents. You should perform the test/inspection and corrective action in the order listed.

b. This manual cannot list all malfunctions that may occur, nor all test or inspections and corrective actions.If a malfunction is not listed or is not corrected by listed corrective actions, notify your supervisor.

c. Only those corrective procedures that can be performed by operator are listed in the table.

d. Use the following symptom index to locate troubleshooting procedures.

SYMPTOM INDEX

TroubleshootingMalfunction Symptom Procedure

Page

1. PRESSURE LOW IN LINER. 3-22. PRESSURE LOW IN PE. 3-33. BLOWER DOES NOT OPERATE. 3-44. RECIRCULATION FILTER DOES NOT OPERATE. 3-45. DOME LIGHT IN PE NOT WORKING. 3-4

3-1

Page 83: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

TROUBLESHOOTING

MALFUNCTIONTEST OR INSPECTION

CORRECTIVE ACTION

1. PRESSURE LOW IN LINER.

Step 1. Check to see if blower has stopped.See malfunction 3.

Step 2. Check for improper adjustment of vents on PE doors.Properly adjust vents (para 2-8h).

Step 3. Check to see if tubing is securely connected to the gage and outlet port.Securely connect tubing.

Step 4. Check to see if PE doors are not completely closed.Properly close PE doors.

Step 5. Check for punctures or tears in PE.Seal as required to stop air leakage (para 3-3).

Step 6. Check for improper hook-and-pile seal between PE and room liner.Open PE door to liner and one outer PE door to reduce pressure, then resealhook-and-pile fasteners.

Step 7. Check for improper hook-and-pile seal between liners and room adapter.Seal as required to stop air leakage.

Step 8. Check for improper attachment of ECU adapter.Properly attach ECU adapter (para 2-8).

Step 9. Check that all duct sleeves and cable are closed.Properly close all duct sleeves and cable sleeves (para 2-8).

3-2

Page 84: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

TROUBLESHOOTING (CONT)

MALFUNCTIONTEST OR INSPECTION

CORRECTIVE ACTION

Step 10. Check for punctures or tears in liners (top, bottom, and sides).Seal as required to stop air leakage (para 3-3).

Step 11. Check air ducts for punctures, tears, or improper connection.Restore ducts to operational condition (para 3-3). Properly connect air ducts (para 2-8).

Step 12. Check air ducts and HSFC for obstructions.Remove obstructions.

Step 13. Notify unit maintenance.

2. PRESSURE LOW IN PE.

Step 1. Check to see if blower has stopped.See malfunction 3.

Step 2. Check for improper adjustment of vents on PE doors.Properly adjust vents (para 2-8).

Step 3. Check to see if tubing is securely connected to the gage and outlet port.Securely connect tubing.

Step 4. Check to see if PE doors are properly closed.Properly close PE doors.

Step 5. Check for punctures or tears in PE.Seal to stop air leakage (para 3-3).

Step 6. Check air ducts for punctures, tears, or improper connection.Restore ducts to operational condition (para 3-3). Properly connect air ducts (para 2-8).

Step 7. Check air ducts and HSFC for obstructions.Remove obstructions.

Step 8. Notify Unit Maintenance.

3-3

Page 85: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

TROUBLESHOOTING (CONT)

MALFUNCTIONTEST OR INSPECTION

CORRECTIVE ACTION

3. BLOWER DOES NOT OPERATE.

Step 1. Check for disconnected input power cable.Connect input power cable.

Step 2. Check to see if blower switch is in up (on) position.Cycle switch to full down (off) position then to up (on) position.

Step 3. Notify Unit Maintenance.

4. RECIRCULATION FILTER DOES NOT OPERATE.

Step 1. Check for disconnected input power cable.Re-connect input power cable.

Step 2. Check to see if recirculation filter blower power switch is in up (on) position.Switch power switch to up (on) position.

Step 3. Notify Unit Maintenance.

5. DOME LIGHT IN PE NOT WORKING.

Step 1. Check to see if blower switch is in up (on) position.Cycle switch to full down (off) position then switch to up (on) position.

Step 2. Check for disconnected or improperly connected electrical cables or cords.Properly connect electrical cables and cords (para 2-8).

Step 3. Notify Unit Maintenance.

3-4

Page 86: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section III. MAINTENANCE PROCEDURES

3-3. OPERATOR MAINTENANCE.

Operator maintenance is limited to inspection and repair of room liner fabric components, and replacing hoseadapter and filter adapter gaskets.

a. Inspecting. Inspect components of the SCPE as described in PMCS (para 2-5).

b. Repairing. Room liners, PE fabric, ECU adapter duct and air duct hoses can be restored to operating conditionusing tape from accessory package.

To repair straight tears on room liner, ECU adapter duct and PE fabric.

NOTE

Silicone is applied to the zippers to permit easier opening and closing. The repair tape will notstick to areas covered with silicone.

(1) If the area to be repaired is near the zippers use alcohol (Item 1, App D) and a wiping rag (Item 10, App D)to clean surface prior to taping.

(2) Cut or tear a strip of tape (Item 12, App D), stored in the accessory package, approximately 4 incheslonger than damaged area.

(3) Position tape over damaged area, pressing firmly in place from top to bottom.

(4) Use cross strips of tape for added strength.

To repair corner cuts or punctures on room liners, ECU adapter duct, and PE fabric.

(1) Using pocket knife, (Item 6, App D) cut repair material, located in accessory package, large enough tocover damaged area.

(2) Cut or tear a strip of tape approximately 4 inches longer than patch.

(3) Position patch on damaged area and firmly press tape around the edges.

3-5

Page 87: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

3-3. OPERATOR MAINTENANCE (CONT).

To repair damaged air ducts.

(1) Cut or tear a piece of tape 4 inches longer than cut or slit.

(2) Position tape on outside of duct and press firmly in place. For added strength position extra tapecompletely around taped area of duct.

c. Replacing Gaskets. This procedure is used for the hose adapter and the filter adapter.

(1) Remove old gasket (1 or 2).

(2) Using knife (Item 6, App D), scrape old adhesive and gasket material from the adapter surface.

(3) Peel away backing tape from new adapter gasket.

(4) Position gasket on adapter (3) with adhesive side toward hose; press firmly in place.

3-6

Page 88: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

APPENDIX AREFERENCES

A-1. SCOPE

This appendix lists all technical manuals, field manuals, DA Pamphlets, forms, and bulletins in this manual.

A-2. TECHNICAL MANUALS

Destruction of Chemical Weapons and Defense Equipment to Prevent Enemy Use...................... TM 43-0002-31Chemical, Toxicological and Missile Fuel Handler Protective Clothing .......................................... TM 10-277Operator/Crew, Organizational, Intermediate (Field) (Direct Support and

General Support) and Depot Maintenance Manual for Generator Set,Gasoline Engine Driven, Skid Mounted, Tubular Frame ................................................... TM 5-6115-323-14

A-3. FIELD MANUALS

NBC Protection ...................................................................................................................... FM 3-4NBC Decontamination................................................................................................................... FM 3-5First Aid for Soldiers ..................................................................................................................... FM 21-11

A-4. DA PAMPHLETS

The Army Maintenance Management System (TAMMS) .. ............................................................ DA PAM 738-750Functional Users Manual for the Army Maintenance Management

System-Aviation (TAMMS-A............................................................................................. DA PAM 738-751

A-5. DA FORMS

Recommended Changes to Equipment Technical Publications ..................................................... DA FORM 2028-2Equipment Inspection and Maintenance Worksheet ...................................................................... DA FORM 2404

A-6. STANDARD FORMS

Quality Deficiency Report.............................................................................................................. SF 368Report of Discrepancies ................................................................................................................ SF 364

A-7. OTHER

Common Table of Allowances ...................................................................................................... CTA 8-100/CTA 50-970

A-1/(A-2 blank)

Page 89: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

APPENDIX BCOMPONENTS OF END ITEM

ANDBASIC ISSUE ITEMS LIST

Section I. INTRODUCTION

C-1. SCOPE

This appendix lists components of the end item and basic issue items for the M20AI Simplified Collective ProtectionEquipment (SCPE) to help you inventory the items for safe and efficient operation of the equipment.

C-2. GENERAL

The Components of End Item and Basic Issue Items (BII) Lists are divided into the following sections:

a. Column (1), Illus Number, gives you the number of the item illustrated.

b. Column (2), National Stock Number, identifies the stock number of the item to be used for requisitioningpurposes.

c. Column (3), Description and Usable On Code, identifies the Federal item name followed by a minimumdescription when needed. The last line below the description is the CAGEC (commercial and Government entity code) inparenthesis and the part number.

d. Column (4), U/I (unit of issue), indicates how the item is issued for the National Stock Number shown in columntwo.

e. Column (5), Qty Rqd, indicates the quantity required.

B-1

Page 90: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section II. COMPONENTS OF END ITEM

(1) (2) (3) (4) (5)Illus National Stock Description Usable on Qty

Number Number CAGEC and Part Number Code U/I Rqr

1 4240-01-331-0170 Room SCPE Liner Package EA 1(81361) 5-19-11334

2 4240-01-331-2938 Pressurized Protective Entrance EA 1(81361) 5-19-11021

3 N/A Accessory Package EA 1(81361) 5-19-11190

4 4240-01-178-9936 Hermetically Sealed Filter Canister EA 1(81361) 5-19-6868

5 4240-01-348-5257 Recirculation Filter EA 1(81361) 5-19-10878

On-board Spares1 4240-01-331-0170 Room SCPE Liner Package EA 2

(81361) 5-19-11334

B-2

Page 91: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section III. BASIC ISSUE ITEMS

(1) (2) (3) (4) (5)Illus National Stock Description Usable on Qty

Number Number CAGEC and Part Number Code U/I Rqr

TECHNICAL MANUAL: EA 1Operator's Manual, Simplified CollectiveProtection Equipment: NBC, M20A1,TM 34240-313-10

B-3/(B-4 blank)

Page 92: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

APPENDIX CADDITIONAL AUTHORIZATION LIST

Section I. INTRODUCTION

C-1. SCOPE

This appendix lists additional items you are authorized for the support of the M20A1 NBC Simplified Collective ProtectionEquipment (SCPE).

C-2. GENERAL

This list identifies items that do not have to accompany the M20A1 NBC SCPE and do not have to be turned in with it.These items are authorized to you by CTA, MTOE, TDA, or JTA.

C-3. EXPLANATION OF LISTING

National stock numbers, descriptions, and quantities are provided to help you identify and request the additional itemsyou require to support this equipment. The items are listed in alphabetical sequence by item name. If the item yourequire differs between serial numbers of the same model, effective serial numbers are shown in the last line of thedescription. If item required differs for different models of this equipment, the model is shown under the 'USABLE ONCODE" heading in the description column.

Section II. ADDITIONAL AUTHORIZATION LIST

(1) (2) (4) (5)National Description

Stock CAGEC and QtyNumber Part Number Usable on Code U/I Rqr

MTOE Authorized Items4240-01-331-3253 ADAPTER, HORIZONTAL, ECU EA 1

(81361) 5-19-11381-20

4240-01-331-0170 ADAPTER, VERTICAL, ECU EA 1(81361) 5-19-11381-10

6115-01-150-4140 GENERATOR SET, DIESEL EA 1ENGINE, 3 Kw(30554) MEP-016B

C-1/(C-2 blank)

Page 93: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

APPENDIX DEXPENDABLE AND DURABLE ITEMS LIST

D-1. SCOPE

This appendix lists expendable and durable items that you will need to operate and maintain the M20A1 NBC SimplifiedCollective Protection Equipment (SCPE). This listing is for information only and is not authority to requisition the listeditems. These items are authorized to you by CTA 50-970, Expendable/Durable Items (except medical, class V repairparts, and heraldic items), or CTA 8-100, Army Medical Department Expendable/Durable Items.

D-2. EXPLANATION OF COLUMNS

a. Column 1. Item Number. This number is assigned to the entry in the listing and is referenced in the narrativeinstructions to identify the item (e.g. "Use pocket knife, Item 6, Appendix D").

b. Column 2. Level. This column identifies the lowest level of maintenance that requires the item.

c. Column 3. National Stock Number. This is the national stock number assigned to the item which you can useto requisition it.

d. Column 4. Item Name, Description, Commercial and Government Entity Code (CAGEC), and PartNumber. This provides the other information you need to identify the item.

e. Column 5. Unit of Measure. This code shows the physical measurement or count of an item, such as gallon,dozen, gross, etc.

Section II. EXPENDABLE/DURABLE ITEMS LIST

(1) (2) (3) (4) (5)Item National ITEM NAME, DESCRIPTION

Number Level Stock Number CAGEC AND PART NUMBER U/M

1 C 6510-01-091-8200 ALCOHOL: PAD, ISOPROPYL EAswab, 1.75 in. width x 1.75 in. length(24065) MA-24-80

2 C 8105-01-142-9345 BAG, SAND: plastic, poly- EApropylene, single wall(81349) MIL-B-52472

3 C 4230-01-101-3984 DECONTAMINATING KIT: EAM258A1(81361) 5-77-2366

D-1

Page 94: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Section II. EXPENDABLE/DURABLE ITEMS LIST (CONT)

(1) (2) (3) (4) (5)Item National ITEM NAME, DESCRIPTION

Number Level Stock Number CAGEC AND PART NUMBER U/M

4 C 6665-01-133-4964 DETECTOR KIT: M256A1 EA(81361) D5-77-2240

5 C 5120-00-900-6110 HAMMER, HAND: E22, EAcarpenters(81348) GGG-H-86

6 C 5110-00-162-2205 KNIFE, POCKET EA(81349) MIL-K-818C

7 C 8340-00-252-2297 LINE, TENT FT(81349) MIL-L-1709 Class A

8 C 5510-00-272-9060 LUMBER, SOFTWOOD, BOARD: BF30 ft., 1 in. thick by 3 in. wide by6 ft. random length(81349) MIL-B-52472

9 C 5315-00-753-3883 NAIL: 3 in. length, 5 lb. LB(81348) FF-N-105

10 C 7920-00-205-1711 RAG, WIPING: 50 lb. BE(58536) A-A-531

11 C 5120-00-542-3438 SCREWDRIVER, CROSS TIP EA(81348) GGG-S-121

12 C 7510-01-266-0326 TAPE, PRESSURE SENSITIVE RO(86984) PPP-T-60

D-2

Page 95: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

INDEXSubject Page

AAbbreviations ...................................................................................................................................... 1-2Accessory Package

Description .................................................................................................................................. 1-7Inspection Before Operation ........................................................................................................ 2-10Inspection After Operation .......................................................................................................... 2-19

Adapter CablesConnection.................................................................................................................................. 2-33Description .................................................................................................................................. 1-7Disconnect .................................................................................................................................. 2-45Inspection.................................................................................................................................... 2-10

Additional Authorization List, Appendix C............................................................................................ C-1Adjusting Internal Pressure ................................................................................................................. 2-36Air Duct

Assembling with HSFC and Motor Blower ................................................................................... 2-31Disconnect .................................................................................................................................. 2-46Functional Description ................................................................................................................ 1-10Inspection Before Operation ....................................................................................................... 2-12Repair ......................................................................................................................................... 3-5

BBasic Issue Items ............................................................................................................................... B-3Bell Timer (see Interval Timer)Blower

Controls and Indicators ............................................................................................................... 2-2Decals and Instruction Plates ...................................................................................................... 2-60Disconnect .................................................................................................................................. 2-45Functional Description ................................................................................................................ 1-10HSFC, Assembling ..................................................................................................................... 2-28Inspection After Operation .......................................................................................................... 2-20Inspection Before Operation ........................................................................................................ 2-11Inspection During Operation ....................................................................................................... 2-16

CCharacteristics, Capabilities, and Features, Equipment ...................................................................... 1-3Components of End Item .................................................................................................................... B-2Components of End Item and Basic Issue Items, Appendix B.............................................................. B-IControls and Indicators........................................................................................................................ 2-1Corrosion Data Feedback ................................................................................................................... 1-2

Index-1

Page 96: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Subject PageD

Decals and Instruction Plates, Operating Instructions ......................................................................... 240Decontaminating SCPE ...................................................................................................................... 2-45Deploying SCPE in NBC Environment ............................................................................................... 2-66Destruction of Army Material to Prevent Enemy Use .......................................................................... 1-1Differences Between Models ............................................................................................................... 1-8Differential Pressure Gage (see Gage)Dimensions and Weights .................................................................................................................... 1-9Disassembly of SCPE ........................................................................................................................ 245Dome Light

Functional Description ................................................................................................................ 1-10Inspection During Operation ....................................................................................................... 2-15

EECU Adapter

Description .................................................................................................................................. 1-8Installation, Horizontal ................................................................................................................. 2-38Installation, Vertical .................................................................................................................... 2-40Striking, Horizontal ...................................................................................................................... 2-53Striking, Vertical .......................................................................................................................... 2-55

Entry Procedures, Protective Entrance ............................................................................................... 2-43Equipment Characteristics, Capabilities, and Features ....................................................................... 1-3Equipment Data ................................................................................................................................. 1-9Equipment Improvement Recommendations, Reporting...................................................................... 1-1Exit Procedures, Protective Entrance.................................................................................................. 244Expendable/Durable Supplies and Materials List, Appendix D ............................................................ D-1Extension Light

Description .................................................................................................................................. 1-7Inspection Before Operation ....................................................................................................... 2-12Inspection During Operation ....................................................................................................... 2-17Removing ................................................................................................................................... 2-46

FFeatures, Capabilities, Characteristics, Equipment ............................................................................. 1-3Filters (see Recirculation Filter; HSFC)Folding Room Liners .......................................................................................................................... 2-58Forms and Records, Maintenance....................................................................................................... 1-1Functional Description of Major Components ..................................................................................... 1-10

Index-2

Page 97: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Subject PageG

GageFunctional Description ................................................................................................................ 1-10Inspection Before Operation ....................................................................................................... 2-9Inspection During Operation ....................................................................................................... 2-16

HHSFC

Crating ........................................................................................................................................ 2-47Decals and Instruction Plates ..................................................................................................... 2-60Description ................................................................................................................................. 1-6Functional Description ................................................................................................................ 1-10Inspection After Operation .......................................................................................................... 2-19Inspection Before Operation ....................................................................................................... 2-9Motor Blower, Assembling .......................................................................................................... 2-31

Hermetically Sealed Filter Canister (see HSFC)High Ceilings, M20A1 SCPE, Used in Areas With .............................................................................. 2-63

IInflating Room Liner ........................................................................................................................... 2-34Inflating Room Liner in NBC Environment .......................................................................................... 2-66Initial Adjustment and Daily Checks ................................................................................................... 2-21Initial Condition M20A1 SCPE ............................................................................................................ 2-21Installation, M20AI Room Liner .......................................................................................................... 2-22Installation in NBC Environment ......................................................................................................... 2-66Installing Liners Without Pressurization .............................................................................................. 2-65Internal Pressure, Adjusting ................................................................................................................ 2-36Interval Timer

Functional Description ................................................................................................................ 1-10Inspection Before Operation ....................................................................................................... 2-8Inspection During Operation ....................................................................................................... 2-15

LLiner (see Room Liner)Location and Description of Major Components .................................................................................. 1-4Lubrication .......................................................................................................................................... 3-1

INDEX-3

Page 98: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Subject PageM

Maintenance Forms and Records........................................................................................................ 1-1Maintenance Procedures .................................................................................................................... 3-5Major Components

Functional Description ................................................................................................................ 1-10Location and Description ............................................................................................................ 1-4

Malfunctions ....................................................................................................................................... 3-1Model Differences .............................................................................................................................. 1-8Motor Blower Assembly (see Blower)Movement, Preparation for ................................................................................................................. 2-44

NNailing................................................................................................................................................. 2-64NBC Environment, Deploying SCPE .................................................................................................. 2-66Nomenclature Cross-Reference ......................................................................................................... 1-2

OOperating Instructions on Decals and Instruction Plates ...................................................................... 2-60Operating Power Requirements .......................................................................................................... 1-9Operating Procedures ........................................................................................................................ 2-43Operation Under Unusual Conditions ................................................................................................. 2-62Operation Under Usual Conditions ..................................................................................................... 2-21Operator Controls and Indicators ........................................................................................................ 2-2Operator Preventive Maintenance Checks and Services (see PMCS)Operator Troubleshooting Procedures ................................................................................................ 3-1

PPMCS ................................................................................................................................................ 2-5PMCS

After ............................................................................................................................................ 2-18Before ........................................................................................................................................ 2-6During ........................................................................................................................................ 2-14

Power CablesConnection.................................................................................................................................. 2-33Description .................................................................................................................................. 1-7Disconnection.............................................................................................................................. 2-45Inspection ................................................................................................................................... 2-11

Power Requirements .......................................................................................................................... 1-9Preparation for Movement .................................................................................................................. 244Preparation and Assembly for Use ...................................................................................................... 2-21Pressure Gage (see Gage)

INDEX-4

Page 99: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Subject PageP (CONT)

Pressure, Adjusting Internal ................................................................................................................ 2-36Pressurized, Installing Without ........................................................................................................... 2-65Pressurized Protective Entrance (see Protective Entrance)Preventive Maintenance Checks and Services, Operator (see PMCS)Principles of Operation, Technical ...................................................................................................... 1-10Procedures

Assembly .................................................................................................................................... 2-21Maintenance................................................................................................................................ 3-5Operating .................................................................................................................................... 2-43Protective Entrance Entry ........................................................................................................... 2-43Protective Entrance Exit ............................................................................................................. 2-44

Protective EntranceControls and Indicators ............................................................................................................... 2-2Decals and Instruction Plates ..................................................................................................... 2-60Description .................................................................................................................................. 1-5Disassembling............................................................................................................................. 245Entry Procedures ........................................................................................................................ 2-43Exit Procedures .......................................................................................................................... 2-44Fabric Repair ............................................................................................................................. 3-5Functional Description ................................................................................................................ 1-10Inspection Before Operation ........................................................................................................ 2-7Inspection During Operation ....................................................................................................... 2-15Inspection After Operation .......................................................................................................... 2-18Installing ..................................................................................................................................... 2-24Striking........................................................................................................................................ 2-48

RRecirculation Filter

Controls and Indicators ............................................................................................................... 2-4Description .................................................................................................................................. 1-6Functional Description ................................................................................................................ 1-10Installing...................................................................................................................................... 2-34Inspection Before Operation ....................................................................................................... 2-13Inspection During Operation ....................................................................................................... 2-17Inspection After Operation .......................................................................................................... 2-20Removal ..................................................................................................................................... 2-53

Records and Forms, Maintenance ...................................................................................................... 1-1References, Appendix A ..................................................................................................................... A-1Repair Procedures ............................................................................................................................. 3-5Reporting Equipment Improvement Recommendations ...................................................................... 1-1Room Liner

Description ................................................................................................................................. 1-4Folding ........................................................................................................................................ 2-58Functional Description ................................................................................................................ 1-10Inflating ....................................................................................................................................... 2-34

INDEX-5

Page 100: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document

TM 3-4240-313-10

Subject PageR (CONT)

Inflating in NBC Environment ..................................................................................................... 266Inspection After Operation........................................................................................................... 2-18Inspection Before Operation ....................................................................................................... 2-6Inspection During Operation ....................................................................................................... 2-14Installing...................................................................................................................................... 2-22Repair ......................................................................................................................................... 3-5Striking........................................................................................................................................ 2-57

SSandbagging....................................................................................................................................... 2-63SCPE Liners (see Room Liner) ...........................................................................................................Striking SCPE .................................................................................................................................... 2-45Support Kit (see Accessory Package)Symptom Index .................................................................................................................................. 3-1System Description ............................................................................................................................ 1-10

TTechnical Principles of Operation........................................................................................................ 1-10Timer Bell (see Interval Timer)Troubleshooting Procedures, Operator ................................................................................................ 3-1

VVents

Adjusting Internal Pressure ......................................................................................................... 2-36Functional Description ................................................................................................................ 1-10

WWeights and Dimensions .................................................................................................................... 1-9

INDEX-6

Page 101: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document
Page 102: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document
Page 103: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document
Page 104: TM 3-4240-313-10 OPERATOR'S MANUAL - Dragon's Den · TM 3-4240-313-10 OPERATOR'S MANUAL SIMPLIFIED COLLECTIVE PROTECTION EQUIPMENT: M20A1 (NSN 4240-01-330-7806) WARNING - This document