TP, TPD, TPE, TPED - D)TPE(D)inlinecirculator... · 4 Pump data TP, TPD, TPE, TPED Introduction TP

  • View
    234

  • Download
    2

Embed Size (px)

Text of TP, TPD, TPE, TPED - D)TPE(D)inlinecirculator... · 4 Pump data TP, TPD, TPE, TPED Introduction TP

  • GRUNDFOS DATA BOOKLET

    TP, TPD, TPE, TPED In-line circulator pumps

    50 Hz

  • 2

    Contents

    Pump dataIntroduction 4Type key 5Codes for shaft seal 5

    Performance rangePerformance range, 2-pole, PN 6/10/16 6Performance range, 4-pole, PN 6/10/16 7Performance range, 6-pole, PN 16 8Performance range, 2-pole, PN 25 9Performance range, 4-pole, PN 25 10

    Product rangeProduct range, 2-pole, PN 6/10/16 11Product range, 4-pole, PN 6/10/16 13Product range, 6-pole, PN 16 15Product range, 2-pole, PN 25 16Product range, 4-pole, PN 25 17

    Operating conditionsPressure conditions 18Ambient temperature 18

    Pumped liquidsPumped liquids 19Liquid temperature 19List of pumped liquids 20

    TP Series 100 and 200 pumpsTechnical data 22Construction 22Materials 22Mechanical shaft seal 23Connections 23Control 23Product features and benefits 23

    TP Series 300 pumpsTechnical data 24Construction 24Materials 24Mechanical shaft seal 24Connections 25Control 25Product features and benefits 25

    TP Series 400 pumpsTechnical data 26Construction 26Materials 26Mechanical shaft seal 27Connections 27Product features and benefits 27

    TPE Series 2000 pumpsTechnical data 28Construction 28Applications 28Operating modes of twin-head pumps 29Control options 29

    TPE Series 1000 pumpsTechnical data 30Construction 30Applications 30Operating modes of twin-head pumps 31Control options 31

    CommunicationCommunication with TPE, TPED pumps 32Affinity equations 33

    Motors for TP pumpsMotors 34Motor protection 34Electrical data, standard motors 35Electrical data, motors with built-in frequencyconverter 36

    InstallationMechanical installation 37Electrical installation 40

    Flanges for TP pumpsFlange dimensions 42

    Curve chartsHow to read the curve charts 43Curve conditions 44

  • Contents

    Performance curves, technical dataTP, TPD, TPE, TPED, 2-pole, PN 6/10/16 46TP, TPD, TPE, TPED, 4-pole, PN 6/10/16 68TP, TPD, TPE, TPED, 6-pole, PN 16 92TP, 2-pole, PN 25 96TP, 4-pole, PN 25 100

    Weights and shipping volumeTP, TPD, TPE, TPED, 2-pole, PN 6/10/16 114TP, TPD, TPE, TPED, 4-pole, PN 6/10/16 116TP, TPD, 6-pole, PN 6/10/16 117TP, 2-pole, PN 25 117TP, 4-pole, PN 25 118

    AccessoriesUnions and valves 119Counter flanges 120Base plates 124Blanking flanges 126Insulating kits 130Sensors 131Potentiometer 132R100 132G10-LON interface 132EMC-filter 132

    Minimum inlet pressure - NPSHTP, TPD 2-pole, PN 6/10/16 134TP, TPD 4-pole, PN 6/10/16 135TP, TPD 6-pole, PN 16 135TP Series 400, 2-pole, PN 25 136TP Series 400, 4-pole, PN 25 136

    Replacement listReplacement of LM, LP and CLM pumps 137

    Further product documentationWinCAPS 161WebCAPS 162

    3

  • 4

    TP, TPD, TPE, TPED

    Pump data

    IntroductionTP pumps are designed for applications such as

    district heating systems heating systems air-conditioning systems district cooling systems water supply industrial processes industrial cooling.

    The pumps are available with either standard motors (TP and TPD) or electronically speed-controlled motors (TPE and TPED).

    The pumps are all single-stage, in-line centrifugal pumps with standard motor and mechanical shaft seal. The pumps are of the close-coupled type, i.e. pump and motor are separate units. Consequently, the pumps are less sensitive to impurities in the pumped liquid than similar pumps of the canned rotor type.

    The TP range is divided into the following three groups:

    TP Series 100, 200, 300 and 400 pumps (uncon-trolled standard pumps).

    TPE Series 2000 pumps (speed controlled pumps with factory-fitted pressure sensor).

    TPE Series 1000 pumps (speed controlled pumps).

    TP Series 100 with union or flange connection Rp 1 (DN 25) to Rp 1 (DN 32) and motor sizes from 0.12 to 0.25 kW.

    For further information about TP Series 100 with union or flange connection, see page 22.

    TP Series 200 with flange connectionDN 32 to DN 100 and motor sizes from 0.12 to 2.2 kW.

    For further information about TP Series 200 with flange connection, see page 22.

    TP Series 300 with flange connectionDN 32 to DN 150 and motor sizes from 0.25 to 30 kW.

    For further information about TP Series 300 with flange connection, see page 24.

    TP Series 400 with flange connectionGrundfos offers the following two TP Series 400 versions:

    10 bar version with DN 150 to DN 250 flange and motor sizes from 30 to 75 kW.

    25 bar version with DN 100 to DN 400 and motor sizes from 5.5 to 630 kW.

    For further information about TP Series 400 pumps, seepage 26.

    TPE Series 2000 pumpsThe main differences between the TP and the TPE Series 2000 pump range are the motor and the factory-fitted integrated differential-pressure sensor.

    The motors of TPE Series 2000 pumps have built-in frequency converter designed to continuously regulate the pressure to the flow.

    The TPE Series 2000 range is recognized as a pre-set solution for quick and safe installation.

    TPE Series 2000 pumps are based on TP Series 100, 200 and 300 pumps. The pump materials are the same as those of the TP pump range.

    For further information about TPE Series 2000 pumps, see page 28.

    TPE Series 1000 pumpsThe difference between the TP and the TPE Series 1000 pump range is the motor. The motors of TPE Series 1000 pumps have built-in frequency converter.

    Via an external signal (from a sensor or a controller), TPE Series 1000 pumps allow for any configuration and control method required: constant pressure, constant temperature or constant flow. TPE Series 1000 pumps are based on TP Series 100, 200 and 300 pumps. The pump materials are the same as those of the TP pump range.

    For further information about TPE Series 1000 pumps, see page 30.

    Why select a TPE pump?A TPE pump with electronic, speed-controlled adapta-tion of performance offers these obvious benefits:

    Energy savings Increased comfort Control and monitoring of pump performance.

    Furthermore, a TPE pump offers

    communication with the pump.

    ATEX-approved TP pumpsOn request, Grundfos offers TP and TPD pumps with ATEX-approval.

    All ATEX-approved TP pumps are in accordance with Council directive 94/9/EC (Group II, category 3).

    High-efficiency motors2- and 4-pole TP pumps with motor sizes from 1.1 to 90 kW are fitted with high-efficiency motors (EFF 1). EFF 1 is the highest efficiency class defined by CEMEP.

  • Pump data TP, TPD

    , TPE, TPED

    Type key

    Codes for shaft seal

    Example TP E D 65 -120 /2 -S -A -F -A -AUUEPump rangeElectronically speed-controlled pump series 1000/2000Twin-head pumpNominal diameter of suction and discharge ports (DN)Maximum head [dm]Pole numberS = TPE Series 2000 (with factory-fitted differential pressure sensor)Code for pump version:A = Basic versionI = PN 6 flangeX = Special versionCode for pipework connection:F = DIN flangeO = UnionCode for materials:A = Basic versionZ = Bronze pump housing and motor stoolB = Bronze impeller

    Code for shaft seal(incl. other plastic and rubber components in the pump except the neck ring)

    Example B B U EGrundfos type designationA = O-ring seal with fixed seal driverB = Rubber bellows sealD = O-ring seal, balancedG = Bellows seal with reduced seal facesR = O-ring seal with reduced seal facesMaterial of rotating faceA = Carbon, antimony-impregnatedB = Carbon, synthetic resin-impregnatedQ = Silicon carbideU = Tungsten carbideMaterial of stationary seatB = Carbon, synthetic resin-impregnatedQ = Silicon carbideU = Tungsten carbideMaterial of secondary sealE = EPDMP = NBR rubberV = FKM

    5

  • 6

    TP, TPD, TPE, TPED2-pole, PN 6/10/16

    Performance range

    Performance range, 2-pole, PN 6/10/16 (See page 46 for performance curves)

    Note: All QH-curves apply to single-head pumps. For further information about curve conditions, see page 44.The hatched area shows the performance range of TPE pumps.

    TM02

    755

    0 10

    04

    12

    34

    56

    81010

    1520

    3040

    506

    080

    100

    100

    150

    200

    300

    400

    Q [m

    /h

    ]

    2345681015203040506080[m]

    H

    112

    34

    56

    81010

    2030

    4050

    60

    70Q

    [l/s

    ]

    203040506080100

    100

    200

    300

    400

    500

    60

    0

    800

    [kPa

    ]p

    TP(D

    ), TP

    E(D

    )PN

    6/1

    0/1

    6, 2

    -pol

    e, 5

    0 H

    z12

    5-81

    0

    125-

    730

    125-

    570

    100-

    650

    65-3

    4065-

    410

    65-

    460

    65-5

    5065-6

    60

    65-

    720

    65-

    930

    65-1

    90

    65-2

    30

    65-2

    60

    50-1

    60

    50-1

    90

    50-2

    40

    50-2

    90

    50-3

    60

    50-4

    30

    50-4

    40

    50-5

    70

    50-7

    10

    50-8

    30

    50-9

    00

    40-2

    40

    40-3

    0040

    -360

    40-4

    70

    40-5

    80

    32-2

    00

    32-2

    50

    32-3

    20

    32-3

    80

    32-4

    60

    32-5

    80

    100

    -120

    80-1

    20

    65-

    180

    65-

    120

    65-6

    0

    50-1

    80

    50-1

    20

    50-6

    0

    40-2

    70

    40-2

    30

    40-1

    90

    40-1

    80

    40-1

    20 40

    -60

    40-5

    0

    32-2

    30

    32-1

    80

    32-1

    50

    32-1

    20

    32-6

    032-9

    0 R

    25-9

    0 R

    25-5

    0 R

    32-5

    0 R40