Understanding Above Ground Tools
ACCA and ACVG
Gord Parker
CTW 2005 – Calgary
Introduction
• NACE approves 4 tests for determining Coating Condition• AC Current Attenuation• AC Voltage Gradient• DC Voltage Gradient• Pearson Method
• ‘old school’
• Note CIS is NOT one of them• Does not find small defects.
Introduction
• Before joining the Pipeline / Corrosion industry, my schooling was Electronics Engineering Technology.
• This ppt focuses on 2 of the tests ACCA/VG
• Both these inspection techniques are very electrical in nature and are well explained by simple Ohm’s law.
ACCA Introduction
• AC Current Attenuation
• Sometimes called the EM method BUT it doesn’t do anything really tricky with electromagnetics.• I personally think RP0502 should have this reworded
• Simply uses Gauss & Faraday’s well proven laws that the strength of an EM field is proportional to the current through a conductor.
• Working backwards, knowing the EM strength & conductor depth, we can calculate the current.
ACCA Application
• Apply a known and consistent I.
• Measure the current at points along the line.
• Calculate a loss/distance ratio
• Alternately factor in diameter for loss/*area* ratio to compare different diameters
• More loss/distance = worse coating.
• Current loss can also indicate unknown connections, insulator and casing problems.
dB Current
• Expressing current loss as a ratio to current before the loss is more accurate.
• deciBels are a ratio
• Next chart: Loss 1 = ~1000 mA, 2~400, and #3~150.
• Loss 1 *looks* much worse but expressed in dB all are the same. Hence all three features (T’s to similar service mains) are the same size/length.
Current Attenuation Graph
3 steps are different looking in mA but nearly identical in dB
Common Problems
• Current goes UP as you walk away from Tx• Current returning to ground point is sufficiently
concentrated near Tx ground stake to create an EM field that cancels out some of the EM field on the pipe.
• Returns to normal attenuation after ~100m
• Current fluctuates down the line • * Can’t GAIN Current walking away from Source• We are detecting EM fields and they can be distorted by
large metallic objects and other EM fields• Reduce bonds / bleed-over• Some places you just can’t take a reading.
• Deep >10-18’ pipes can sometimes be a problem.
Using ‘TrendLine’ function in Excel
Bad Example #1Example of current that goes up @ reading #47
Also, survey is using <20mA, small errors look big, better to use 100mA+
Survey done with locate frequency, not low (ie:4Hz)
Bad Example #2
Same data but shown on Log vert. axis.
See how first 60% now looks more even compared to linear graph previously.
Segments 0-10 are worse then 10-40
Current can’t go up by any amount, never mind double
AC Frequency• Even through a perfect coating, an AC
signal will bleed off due to capacitive coupling to the ground outside the coating.
• Higher f = higher attenuation.
Bad Example #2
Same graph as previously.
In my opinion, the high attenuation near the beginning is only due to the higher frequency (remember this was done at a locate freq, not 4Hz).
Shielded defects …..
• Higher frequency I will bleed off faster.
• Capacitive impedance drops as f• Remembering we are detecting current loss,
does disbonded coating have a lower impedance?• i.e.: does the pipe-coating-dirt model lose
current faster then the pipe-electrolyte-coating-dirt ? Why ? (the electrolyte isn’t grounded)
Distribution of current. 1kHz vs. 4Hz
1A (1KHz)
400mA
600m
A
200mA
400m
A
1A (4Hz)
40mA
960m
A
900mA
60m
Afault
Because of an overall lower impedance at higher frequencies, current will travel down stubs and short mains (and attenuate faster on all runs).
It also bleeds through what are actually good (DC) insulators.
Surveying at a lower frequency will more accurately mimic where your CP current is going.
Low frequencies go to the short
Troubleshooting Loops
• Current Direction can be seen above ground without contact.
Benefits and Strengths
• Easy to operate by one single operator
• No direct contact to ground necessary
• Near DC fault detection signal makes capacitive effects insignificant
• Low frequency for pipe detection: long distances
• Current Direction facility to enable short identification
• With addition of earth-frame, often same hardware can be used for an AC Voltage Gradient survey.
Benefits and Strengths II
Previously Difficult situations:
• Casings – Now, just check if here is a current loss
• Insulators – If both zones have similar potential, there could be a question as to if insulator is shorted. But in Current Mapping, if there is current getting through to far side piping, there is a short.
• Bonds – large current loss and/or direction reversal show below grade bonds very easily.
Difficult Applications
• We are locating current flow and current does not travel into an open circuit.• Insulating flanges and fittings (ZapLock, Bell&Spigot,
Dresser) will limit current flow along a length of pipe.
• This is still valuable information to locate these and verifies their proper operation.
• Congested areas – confusing EM
• Older equipment was subject to 50/60 Hz interference• Newer circuitry ‘sees’ PCM current through other EM noise.
The Effect of Insulators (i.e.: Dressers™, ZapLock, Bell/Spigots in some conditions.)
• When low resistance connection is in effect, current distribution is uniform
• PCM shows 50/50 split of current
• When joint goes high resistance, current splits unevenly
• PCM (& CP) current drops to undetectable level ahead of open
• (Is still protected – potential is maintained, just takes less current)
Mg Anodes
• Anodes will provide a path to ground for the AC signals we are detecting (4Hz and locate freqs.).
• It may look like a loss but likely a big one
• Any current this big is a short (casing, other utility, insulator), so look for 4 Hz somewhere else as current has to go somewhere. If nowhere else, is a Mg.
• Amount of signal loss will be proportional to anode quality / life expectancy.
Underground Gas Distribution Short to Water
• Quite prevalent, especially in warmer climates (water lines more shallow)
• Hard to find without excavation
• PCM method walked technician right to it.
• Picture of site on next slide
Underground Gas Short
CASE I
N
DE
DE
DE
DE
Insulator
Mainline Insulator DE
100 ma
94 ma
400
ma
No
Sig
nal
475
ma
600 ma95
0 m
a80
5 m
a70
0 m
a
500
ma
2.50 A
100
ma
No
Sig
nal
98 m
a
78 m
a
1.60 A
DE
375 ma450 ma
2.60 A
Typical Mag. anode - connected
Area Rectifier - Anodes used as PCM ground & PCM set @ 3 amperes output
MSA not insulated - 875 ma found on
gas serviceline
875
ma
578
ma
110 ma
2nd Distribution Example
Transmission Coating Survey (and bad insulator)
• Started as just a demonstration, no known problems on line.• Upon connecting transmitter, 85% of signal going in one direction !?!• Drive to next road crossing (only ~1200m) and had already lost 90%
of remaining current, thus problem is between road and transmitter• Perform survey towards transmitter, find 2 areas of higher than
average loss• Found major loss across one point, investigation found a shorted
insulator in underground T connection to foreign compressor site.• If both systems had similar protection levels, a CIPS may not have
shown any defect. • If short had gone unnoticed, stray currents could develop causing
problems and/or rectifier power bills /current rating could be higher than necessary.
Transmission Coating Survey
ACCA Questions ?
ACVG
• AC Voltage Gradient
• Like DCVG / Pin-to-pin / similar but uses a transmitter, not the CP DC
• Sizing similar to DCVG• Empirical testing now underway
ACVG
• An improvement though is to tightly tune the voltmeter to the transmitter frequency
• A Fluke® on DC can find other sources:• Stray current, sacrificial anodes, dissimilar
metals
• A Fluke® on AC isn’t tuned:• Any AC frequency from ~5 Hz - 25kHz
• 60 Hz.AC currents/faults, telephone/scada noise
Pool of PotentialIs AC, but at any instant in time, there is a direction.
ACVG
• Sometimes part of an ACCA tool
• Is a big AC voltmeter
• Voltmeter Leads are the probes
• Results in dB gives very wide dynamic range
• Calibrated amplification reduces a variable
• Consistent lead spacing (a-frame) removes one other variable
ACVG Receiver Theory
ACVG
• Faults (on an otherwise good cable) have been found exceeding 6.8 MΩ
• Very sensitive as it has an extremely high signal-noise ratio
AC Voltage Gradient• Can be part of Current tools
• Becoming very popular
• Extreme sensitivity
• Rejection of interference
• Very accurate location of faults• typically better then 6"
• Sometimes part of Current Attenuation equipment
• This method deserves to be considered as a solid tool for integrity and the ECDA process.
ACVG in Operation
• Both signal strength and direction arrows lead user to holiday.
• Fault value is proportional to holiday size and soil resistivity.
• In this case the next fault was quite close (20-30m) which is why the left side of graph climbs quickly.
• Other cases may show 100s of meters of signal at 30 and under..
ACVG Tuning
• Older systems used a simple DMM• Does not tune to any one frequency
• 60 Hz, cable earth faults, telecom noise Rx’d
• Very tight tuning in the signal generator and receiver effectively increases sensitivity as it ignores current from other sources• SNR improves
ACVG Find• Transversal A-frame dB
readings: 80 (right) and 85 (l)• dB (from PCM) before fault=
49.85,after= 49.48• Distance between readings =
15 meters• 37mB/15m (actually just fault)• Pipe dia.= 12”/PE in two layers• Soil res. @fault:817.63 Ohm x
m• Fault size = 60 mm length x 2
mm wide• Note the higher trans dB
reading on left side that is the same side where valve station is located
Dig Pictures
Jordanian Fire Water Line 16”/30yr old
• “We are using this equipment for locating coating defects on the coal tar epoxy coated pipelines. While doing survey on the pipeline we got 63 dB microvolt with A-Frame. The epicenter of the defect was located by taking readings above and in line with the pipeline and perpendicular to the pipeline. From all four sides direction of arrow was indicated towards the defect. The defect location was excavated.
• “Upon excavation, we could not find bare pipe at this location. What we found was that the coating has degraded badly and it has become permeable. This has happened at two locations.
• “Please advise if the current is flowing through the permeable coating or there are other reasons.”
Sarvjit Singh Corrpro Companies Middle East L.L.C Client : Jordan Petroleum Refinery Company
Sarvjit Singh Corrpro Companies Middle East L.L.C Client : Jordan Petroleum Refinery Company
My Favorite ACCA/VG Story
• 2 mile long distribution main, 25 yr old
• For last 4 years, potentials have been dropping
• Several surveys showed no shorts
• ACCA: in each 100’ span, current was dropping like a rock but no single point of trouble
• ACVG: BAM… BAM… every 40’
• Had spent 40+ person-hours with no resolution. In 45 minutes we found and quantified the problem. The customer could budget digging up 6’ of every 40’ to replace the joint coating.