UNIMASTER DUST COLLECTOR WITH DUST CONTAINER UMA 153 illustrated. Suitable for inside locations. *Secondary filter and absolute filter not available for UMA 72 dust collector. SIDE ELEVATION FRONT ELEVATION Publication 2724E (GB) 0906 Data Sheet Donaldson reserve the right to alter design without notice. Freedom from patent restrictions must not be assumed. Unimaster Dust Collectors Series UMA 70-250 Fan chamber Contaminated air inlet (may be fitted either side or at rear) 380 required for cleaner motor cover removal A Lifting bracket (removable) Terminal box Cleaner motor Filter chamber Quick-release sealer gear Dust container Cleaned air outlet d required for maintenance Joint line 102 e C B f to centre of inlet spigot Acoustic diffuser (may be fitted with optional secondary or absolute filter)* 230 minimum clearance SPECIFICATIONS Inlet spigot Net Filtration DIMENSIONS in mm Motor Dust Type (inside dia.) Fan weight area A B C d e f rating container mm (approx.) UMA 72 6.23 m 2 575 575 2029 600 729 648 101 G1 0.75 kW 55 litre 203 kg G1 0.75 kW 295 kg UMA 103 9.29 m 2 765 575 2535 800 883 685 203 80 litre K3 1.50 kW 300 kg G1 0.75 kW 333 kg K3 1.50 kW 338 kg UMA 153 13.94 m 2 765 765 2591 800 883 685 203 K5 2.20 kW 80 litre 353 kg K7 3.00 kW 378 kg G8 5.50 kW 393 kg G1 0.75 kW 445 kg K3 1.50 kW 450 kg UMA 253 22.67 m 2 1146 765 2942 1150 1099 883 254 K5 2.20 kW 80 litre 465 kg K7 3.00 kW 490 kg G8 5.50 kW 505 kg Donaldson Torit DCE

Unimaster Dust Collectors - ATSats-if.bg/wp-content/uploads/pdf_documents/Unimaster Series UMA 70-250.pdf4 Data Sheet Unimaster Dust Collectors ΠSeries UMA 70-250 SPECIFICATIONS

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

  • UNIMASTER DUST COLLECTOR WITH DUST CONTAINERUMA 153 illustrated. Suitable for inside locations. *Secondary filter and absolute filter not available for UMA 72 dust collector.

    SIDE ELEVATION FRONT ELEVATION

    Publication 2724E (GB) 0906

    Data Sheet

    Donaldson reserve the right to alter design without notice. Freedom from patent restrictions must not be assumed.

    Unimaster Dust CollectorsSeries UMA 70-250

    Fan chamber

    Contaminatedair inlet(may be fittedeither side orat rear)

    380required for cleanermotor cover removal

    A

    Lifting bracket(removable)

    Terminal box

    Cleaner motor

    Filter chamber

    Quick-releasesealer gear

    Dust container

    Cleaned airoutlet

    drequired formaintenance

    Joint line

    102

    e

    C

    B

    fto centre ofinlet spigot

    Acoustic diffuser(may be fitted withoptional secondary orabsolute filter)*

    230minimumclearance

    SPECIFICATIONSInlet spigot NetFiltration DIMENSIONS in mm Motor DustType (inside dia.) Fan weightarea A B C d e f rating containermm (approx.)

    UMA 72 6.23 m2 575 575 2029 600 729 648 ∅ 101 G1 0.75 kW 55 litre 203 kg

    G1 0.75 kW 295 kgUMA 103 9.29 m2 765 575 2535 800 883 685 ∅ 203 80 litreK3 1.50 kW 300 kg

    G1 0.75 kW 333 kgK3 1.50 kW 338 kg

    UMA 153 13.94 m2 765 765 2591 800 883 685 ∅ 203 K5 2.20 kW 80 litre 353 kgK7 3.00 kW 378 kgG8 5.50 kW 393 kg

    G1 0.75 kW 445 kgK3 1.50 kW 450 kg

    UMA 253 22.67 m2 1146 765 2942 1150 1099 883 ∅ 254 K5 2.20 kW 80 litre 465 kgK7 3.00 kW 490 kgG8 5.50 kW 505 kg

    Donaldson®Torit®DCE®

  • 2

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    SPECIFICATIONSNetFiltration DIMENSIONS in mm MotorType Fan weightarea A B C d rating (approx.)

    UMA 70H 6.23 m2 575 575 1338 600 G1 0.75 kW 170 kg

    G1 0.75 kW 235 kgUMA 100H 9.29 m2 765 575 1652 800 K3 1.50 kW 240 kg

    G1 0.75 kW 270 kgK3 1.50 kW 275 kg

    UMA 150H 13.94 m2 765 765 1708 800 K5 2.20 kW 290 kgK7 3.00 kW 315 kgG8 5.50 kW 330 kg

    G1 0.75 kW 355 kgK3 1.50 kW 360 kg

    UMA 250H 22.67 m2 1146 765 1843 1150 K5 2.20 kW 375 kgK7 3.00 kW 400 kgG8 5.50 kW 415 kg

    UNIMASTER HOPPER TYPE DUST COLLECTORUMA 150H illustrated. Suitable for inside locations. *Secondary filter and absolute filter not available for UMA 70H dust collector.

    SIDE ELEVATION FRONT ELEVATION

    Fan chamber

    380required for cleanermotor cover removal

    A

    Lifting bracket(removable)

    Terminal box

    Cleaner motor

    Filter chamber

    Cleaned airoutlet

    drequired formaintenance

    102

    C

    B

    Acoustic diffuser(may be fitted withoptional secondary orabsolute filter)*

    230minimumclearance

    S e a t i n g l e v e l

    ApproxSize net weight

    55 litre 5 kg80 litre 6 kg

    A reasonable total load forremoval by hand would be 25 kg

    55 litre(2 cu.ft.)

    DUST CONTAINERTypical dust densities

    Density withDust 50% voidageSander 0.13 kg/litreGraphite 0.80 kg/litreSand 1.33 kg/litreIron 3.58 kg/litreSteel 3.72 kg/litre

    80 litre(3 cu.ft.)

    Donaldson®Torit®DCE®

  • 3

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    380required for cleanermotor cover removal

    A

    Lifting bracket(removable)

    Cleaned airoutlet

    drequired formaintenance

    90

    B230

    minimumclearance

    CCleaner motorFilter chamber

    S e a t i n g l e v e l

    SPECIFICATIONSNetFiltration DIMENSIONS in mmType weightarea A B C d (approx.)

    UMA 70V 6.23 m2 575 575 678 560 93 kg

    UMA 100V 9.29 m2 765 575 678 560 114 kg

    UMA 150V 13.94 m2 765 765 735 760 135 kg

    UMA 250V 22.67 m2 1146 765 735 760 175 kg

    UNIMASTER VENTING TYPE DUST COLLECTORUMA 150V illustrated. Suitable for inside locations and outside when fitted with optional weather cowl.

    SIDE ELEVATION FRONT ELEVATION

    SPECIFICATIONSInlet spigot NetFiltration DIMENSIONS in mm DustType (inside dia.) weightarea A B C d e f containermm (approx.)

    UMA 72V 6.23 m2 575 575 1369 560 729 648 ∅ 101 55 litre 126 kg

    UMA 103V 9.29 m2 765 575 1485 560 845 685 ∅ 203 80 litre 174 kg

    UMA 153V 13.94 m2 765 765 1542 760 845 685 ∅ 203 80 litre 199 kg

    UMA 253V 22.67 m2 1146 765 1758 760 1061 883 ∅ 254 80 litre 265 kg

    Contaminatedair inlet(may be fittedeither side orat rear)

    380required for cleanermotor cover removal

    A

    Lifting bracket(removable)

    Cleaner motorFilter chamber

    Quick-releasesealer gear

    Dust container

    Cleaned airoutlet

    drequired formaintenance

    Joint line

    90

    e

    C

    B

    fto centre ofinlet spigot

    230minimumclearance

    UNIMASTER VENTING TYPE DUST COLLECTOR WITH DUST CONTAINERUMA 153V illustrated. Suitable for inside locations and outside when fitted with optional weather cowl.

    SIDE ELEVATION FRONT ELEVATION

    Donaldson®Torit®DCE®

    Donaldson®Torit®DCE®

  • 4

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    SPECIFICATIONSNetFiltration DIMENSIONS in mm MotorType Fan weightarea A B C d e rating (approx.)

    UMA 100STU 9.29 m2 765 575 2706 800 1054 K3 1.50 kW 313 kg

    UMA 150STU 13.94 m2 765 765 2762 800 1054 K3 1.50 kW 368 kg

    UMA 250STU 22.67 m2 1146 765 2897 1150 1054 K3 1.50 kW 553 kg

    Fan chamber

    380required for cleanermotor cover removal

    A

    Lifting bracket(removable)

    Terminal box

    Cleaner motor

    Filter chamber

    Cleaned airoutlet

    drequired formaintenance

    102

    C

    B

    Acoustic diffuser(may be fitted withoptional secondary orabsolute filter)

    230minimumclearance

    S e a t i n g l e v e l

    Alternative insertwith swing doorfor sack tipping unitsfitted with optionalexplosion relief panelsOpening:585 wide x 665 deep

    Quick-release hatch(removed when tipping)Standard opening onall models:680 wide x 700 deep

    Joint line

    e

    UNIMASTER SACK TIPPING UNITUMA 150STU illustrated. Suitable for inside locations.

    SIDE ELEVATION FRONT ELEVATION

    DESIGN LIMITS (standard equipment)

    Temperature range: −10° to +60°C

    Pressure limits: Collectors with fan: as fan performance curves from shut-off to operating pressureVenting type collectors: −300 mmW.G. to +250 mm W.G.

    Dimension tolerances: ±3 mm on main dimensions; ±2 mm on detail dimensions

    Equipment suitable for use in a potentially explosive atmosphere (Directive 94/9/EC)satisfying the requirements for group II category 2D and 3D T135°C is available

    Donaldson®Torit®DCE®

  • 5

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    193=

    37

    = 193= =

    284= =

    193

    =

    =

    284

    =

    =

    284

    =

    =

    120

    120

    37

    130

    46.5

    46.5

    13046.546.5

    111.5 111.5

    37120

    37120

    37

    120

    120

    37

    UMA 70V UMA 100V and 150V

    UMA 250V

    CLEANED AIR OUTLET DETAILS FOR VENTING TYPE COLLECTORSAll holes ∅4 mm

    DIMENSIONS in mmType A B c

    UMA 70 225 225 116

    UMA 100 295 250 116

    UMA 150 320 320 116

    UMA 250 340 340 403

    A

    B

    40

    CLEANED AIR OUTLET DETAILSUMA 150 illustrated

    c

  • 6

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    UMA 70H and 70V

    APERTURE AND MOUNTING FLANGE DETAILS FOR HOPPER AND VENTING TYPE COLLECTORSAll holes ∅12 mm for M10 bolts

    205200 8520520020585

    85

    205

    225

    205

    8535 1145

    1215

    3535

    765 835

    35205225 8520585

    85

    205

    225

    205

    8535 35

    35

    765 835

    35

    765

    835

    205225 8520585

    40

    180

    175

    180

    4035 35

    35

    575 645

    35

    765

    835

    180175 4018040

    40

    180

    175

    180

    4035 35

    35

    575 645

    35

    575

    645

    UMA 100H and 100V

    UMA 150H and 150V UMA 250H and 250V

  • 7

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    285 285 125125

    190

    190

    125

    125

    575 675

    50

    50765

    865

    5050

    285 285 125125

    285

    285

    125

    125

    765 865

    50

    50765

    865

    5050

    475 475 125125

    285

    285

    125

    125

    765 865

    50

    5050

    50 1145

    1245

    UMA 100STU UMA 150STU

    UMA 250STU

    APERTURE AND MOUNTING FLANGE DETAILS FOR SACK TIPPING UNITSAll holes ∅12 mm for M10 bolts

    Safety bars(30 x 30 x 5 RSA)welded at equalintervals betweenside members

  • 8

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    0 500 1000 1500 2000 2500 3000 3500 4000

    AIR VOLUME (m3/h)

    400

    350

    300

    250

    200

    150

    100

    50STATICPRESSUREATFANINLET(mmW.G.)

    UNIT PERFORMANCE CURVES

    FAN SELECTION

    These curves indicate static pressure available at fan inlet for a given volume when fitted inside aUnimaster dust collector.

    To select the most suitable fan for a given application:

    1 Determine the air volume, in m3/h, needed to entrain the dust.

    2 Read off the unit resistance, in mm W.G., at air volume required.

    3 Assess pressure drop over filter bags prior to cleaning, usually 50 to 100 mm W.G.

    4 Estimate pressure drop through connected system − i.e. between point of entrainment and collector inlet.5 The sum of 2, 3 and 4 = W.G. required.6 Consult graph for fan performances available.

    Sack Tipping Units have K3 (1.5 kW) fans with modified outlet to ensure adequate face velocities at the tipping hatchunder normal operating conditions. Typically, the exhaust rate for the UMA 250STU is 1275 m3/h (750 cfm).

    K7

    K5K

    3

    G1

    UNITRES

    ISTANCE

    CURVE

    G8

    ELECTRICALREQUIREMENTS

    UCS Controller

    Voltage input: 220-240V, Single Phase, 50Hz (for collectors with G1 or K3 fans only)218-242V / 380-420V, Three Phase, 50Hz250-277V / 440-480V, Three Phase, 60Hz

    or to suit local voltage

  • 9

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    NOISE LEVELS

    Machinery noise levels are an important consideration in the design and selection of new equipment.Several EC Directives and National Laws/Regulations adopting these directives make reference to airborne noise emissions.

    Actions that employers are required to comply with if employees are subjected to a daily personal noiseexposure Lep,d of 85 dB(A) or more are also specified.

    All Unimaster dust collectors, when fitted with an acoustic diffuser, secondary filter or absolute filter,operating an 8 hour shift, are below this action limit.

    OPTIONAL WEATHER COWLUMA 150V illustrated

    SIDE ELEVATION(Detail of cleaned air outlet withweather cowl and lid removed)

    FRONT ELEVATIONSIDE ELEVATION

    A150

    minimumclearance

    194Bc= =

    109 175

    29

    SPECIFICATIONSNetDIMENSIONS in mmType weightA B c (approx.)

    UMA 70V 585 584 473 12 kg

    UMA 100V 775 584 473 12 kg

    UMA 150V 775 774 697 19 kg

    UMA 250V 1156 774 697 19 kg

    WEIGHTED SOUND PRESSURE LEVELS

    All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent.Measurements were taken at maximum air flow conditions at 1.0 metre radius from the equipment housing

    and 1.6 metres above base level, using a precision sound level meter and octave filter.

    G1 K3 K5 K7 G8

    With acoustic diffuser 65 dB(A) 67 dB(A) 68 dB(A) 69 dB(A)� 72 dB(A)With secondary filter * 67 dB(A) 68 dB(A) 69 dB(A) 72 dB(A)With absolute filter * 67 dB(A) 68 dB(A) 69 dB(A) 72 dB(A)

    Noise levels of installed equipment may vary due to site conditions.*Secondary and absolute filter not supplied with G1 fan. �Measured data.

  • 10

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    SIDE ELEVATIONREAR ELEVATION

    POSITION OF OPTIONAL EXPLOSION RELIEF FLANGEUMA 153 illustrated

    80

    SIDE ELEVATIONREAR ELEVATION

    POSITIONOFOPTIONALEXPLOSIONRELIEFFLANGESFORSACKTIPPINGUNITSUMA 150STU illustrated

    If vent ducts are not connected to the explosion relief flanges, then a minimum clearance of 500 mm should be madeto the rear of the collector to ensure efficient operation of the explosion venting process. Consideration should be given to the

    local surrounding area in regards to the pressure and flame effects.

    80

    100

    152 (UMA 100)209 (UMA 150)143 (UMA 250)

    548 (UMA 100 and 150)614 (UMA 250)

    468 (UMA 100 and 150)402 (UMA 250)

    Joint line

    UMA type: 72 103 153 253 70H 100H 150H 250H 70V 100V 150V 250V 72V 103V 153V 253V

    Dimension A in mm: 76 114 171 105 114 114 171 105 114 114 171 105 76 76 133 67

    A

    If a vent duct is not connected to the explosion relief flange, then a minimum clearance of 500 mm should be madeto the rear of the collector to ensure efficient operation of the explosion venting process. Consideration should be given to the

    local surrounding area in regards to the pressure and flame effects.

  • 11

    Data Sheet

    Unimaster Dust Collectors Series UMA 70-250

    548468

    40

    4040452

    532

    4044

    44

    20

    20

    51 513 pitches @ 130 mm

    3 pitches@ 140 mm

    74 744 pitches @ 130 mm

    40628

    708

    4044

    44

    20

    3 pitches@ 140 mm 548468

    40

    40

    59.5 59.57 pitches @ 135 mm

    614534

    40

    40

    20

    20

    27

    27

    20

    4 pitches@ 130 mm

    401024

    1104

    40

    UMA 70 UMA 100 and 150

    UMA 250

    OPTIONAL EXPLOSION RELIEF FLANGE MOUNTING DETAILSAll vertical holes drilled ∅10 mm for M8 bolts. All horizontal holes threaded to accept M8 bolts.

  • Humberstone LaneThurmastonLeicester LE4 8HPEngland

    Tel +44 (0)116 269 6161Fax +44 (0)116 269 3028

    Email: [email protected]

    www.donaldson.com

    Research Park Zone 1Interleuvenlaan 1B-3001 Leuven (Heverlee)Belgium

    Tel +32 (0)16 383 970Fax +32 (0)16 383 938

    Email: [email protected]