USER MANUAL - Totally Wicked 3 Congratulations on purchasing your Totally Wicked Tornado II Sub Mega VT Electronic Cigarette. The Tornado II Sub Mega VT is a compact and unique e-cigarette

  • View
    217

  • Download
    4

Embed Size (px)

Text of USER MANUAL - Totally Wicked 3 Congratulations on purchasing your Totally Wicked Tornado II Sub Mega...

  • USER MANUAL

    BEDIENUNGSANLEITUNG

    TW Tornado 2 Sub Mega VT Manual.indd 1 08/10/2015 16:52

  • 2 3

    Congratulations on purchasing yourTotally Wicked Tornado II Sub Mega VT Electronic Cigarette.

    The Tornado II Sub Mega VT is a compact and unique e-cigarette design incorporating an intelligent temperature control system, allowing you to tune your device to suit your vaping style. The user is provided with three cutting edge modes of operation; variable power (W); variable temperature with nickel coils (Ni); and variable temperature with titanium coils (Ti). Each mode provides three levels - Low/Medium/High - in terms of watts and temperature respectively. The Tornado II Sub Mega VT combines all of its functionality in an elegant and simple to use package, suitable for all electronic cigarette users from beginners to advanced hobbyists.

    Kit contents:

    A. BatteryB. Atomizer Base C. Atomizer Head CL-Ni (0.2ohm)D. Atomizer Head CL-Ti (0.4ohm)E. Atomizer TankF. Mouthpiece

    A B C D E F

    TW Tornado 2 Sub Mega VT Manual.indd 2-3 08/10/2015 16:52

  • 4 5

    Using your Tornado II Sub Mega VT Using your Tornado II Sub Mega VT

    Power On and Off:The Tornado II Sub Mega VT uses a 5-click on/off function. To switch the device on quickly press the power button 5 times. The button light will flash 5 times, indicating that the device is ready to use. Once the Tornado II Sub Mega VT is powered up the user can press the button 5 times to switch the device off, again the button light will flash 5 times now showing that the device is locked.

    Vaping:Press the button as you inhale. When the button is held down, the button light will be illuminated.

    Shift between VT-Ni/VT-Ti/VW Modes:When powered off, long press the power button to cycle through the VT-Ni/VT-Ti/VW modes to adapt to the coil.

    Adjustment of Levels:When powered on, press the power button 3 times consecutively to shift between Low/Medium/High levels of wattage (under VW mode) or temperature (under VT mode) to suit your preference.

    Soak the Atomizer Head:When using a new atomizer head, please drip a few drops of e-liquid in the cotton of the atomizer head to ensure it is moist before the first use to allow for the maximum performance to be achieved.

    TW Tornado 2 Sub Mega VT Manual.indd 4-5 08/10/2015 16:52

  • 6 7

    Using your Tornado II Sub Mega VT Using your Tornado II Sub Mega VT

    To Fill the Tank:Invert the Tornado II Sub Mega VT and unscrew the battery and atomizer base from the tank. Fill the tank through the gap around the central tube.

    Charging the Battery:Simply charge the Tornado II Sub Mega VT via the USB cable connected to a powered USB port or suitable wall adapter. When it is fully charged the red LED will go out.

    Battery Status Indicator:When the power button is pressed the LED beside the power button will indicate the remaining battery life. The light will remain steadily on for 5 seconds if the remaining battery life is greater than 60%; below this the light will pulsate at an increasing speed as the battery life is drained. When the battery reaches below 10% charge remaining, the light will pulsate rapidly.

    Low Voltage Protection:When the battery is completely drained, the button light will flash 40 times, and the device will shut down automatically. To resume connect to a USB charger.

    Short Circuit Protection:If a short circuit occurs when the power button is not pressed, the light will flash 5 times and there will be no output. If a short circuit occurs when the power

    TW Tornado 2 Sub Mega VT Manual.indd 6-7 08/10/2015 16:52

  • 8 9

    Using your Tornado II Sub Mega VTUsing your Tornado II Sub Mega VT

    circuit or an atomizer fault. If an atomizer resistance greater than 5ohms is detected, the button light will continuously flash slowly, indicating an open circuit, no atomizer fitted, or an atomizer fault.

    Atomizer Head ReplacementInvert the Tornado II Sub Mega VT and

    unscrew the battery and atomizer base from the tank. Unscrew the atomizer head and remove from the atomizer base. Screw the new atomizer head into the base and firmly tighten. Refit the atomizer base into the tank. Connect the assembled tank to the battery and the Tornado II Sub Mega VT is ready to use.

    button is pressed, the light will flash 3 times and the output will stop.

    Airflow Adjustment:Airflow resistance can be adjusted for personal taste. Turn the airflow adjustment ring clockwise to tighten the draw, and anticlockwise to loosen.

    Atomizer Protection:During operation, if the button is held down for longer than 15 seconds the button light will flash 10 times and the battery will stop powering to atomizer.

    Atomizer Resistance Detection:If an atomizer resistance lower than 0.3ohms is detected the button light will flash 5 times quickly when the button is pressed, indicating a short

    TW Tornado 2 Sub Mega VT Manual.indd 8-9 08/10/2015 16:52

  • 10 11

    Output Levels for Tornado II Sub Mega VT (VW Mode) Temperature Levels for Tornado II Sub Mega VT (VT Mode)

    Level / Ohm Range 0.4-0.8 Ohm 0.8-1.6 Ohm 1.6-3.5 Ohm

    Low 20W 10W 5W

    Medium 25W 15W 7.5W

    High 30W 20W 10W

    Level Ti/Ni Ti Coil Ni Coil

    Low 220C 220C

    Medium 240C 250C

    High 315C 315C

    TW Tornado 2 Sub Mega VT Manual.indd 10-11 08/10/2015 16:52

  • 12 13

    DOs Store the Tornado II Sub Mega VT and its accessories away

    from children when not in use. Ensure the Tornado II Sub Mega VT is powered off when not

    in use. Avoid accidentally pressing the Tornado II Sub Mega VT power

    button when not in use. Remove the battery when you do not intend to use the Tornado

    II Sub Mega VT for several days. Please only use the charging cable provided. Please dispose of dead batteries in accordance with your

    countrys appropriate legislation. Use only a maximum of 1.0ohm under VT mode. The mode

    will automatically be switched to VW mode when the coil is larger than 1.0ohm or a normal coil is used.

    DONTs Do not charge the batteries in a damp environment. Do not use the device when temperatures are

    outside the range -10 - 60C. Do not charge the battery when temperatures are

    outside the range 0 - 45C. Do not carry batteries in a pocket bag with other

    metallic objects. Do not attempt to repair a faulty Tornado II Sub Mega VT battery

    as these are sealed units with no serviceable parts. Attempted repairs will void the warranty. Do not use temperature control coils under VW mode,

    damage will be caused.

    Resistance RangeVT Mode: 0.2-1.0 OhmVW Mode: 0.4-3.5 Ohm

    Tornado II Sub Mega VT BatteryDimensions: 85.5mm x 22mmCapacity: 2300mAh

    Tornado II Sub Mega VT TankDimensions: 56.5mm x 22mmCapacity: 4ml

    CL Atomizer HeadsCL-Ni (0.2ohm)CL-Ti (0.4ohm)

    Specifications

    TW Tornado 2 Sub Mega VT Manual.indd 12-13 08/10/2015 16:52

  • 14 15

    Wir gratulieren Ihnen zum Kauf der Totally Wicked Tornado II Sub Mega VT E-Zigarette.

    Kit Komponenten:

    Die Totally Wicked Tornado II Sub Mega VT ist eine kompakte und im Design einzigartige E-Zigarette, die mit der intelligenten Temperaturregelung das Dampferlebnis zustzlich positiv beeinflusst. Drei verschiedene Betriebsmodi erlauben dem Nutzer mit variabler Leistung (W), variabler Temperatur mit Nickel- (Ni) oder variabler Temperatur mit Titan- (Ti) Verdampferkpfen zu dampfen. Jeder Modus hat drei unterschiedliche Leistungsstufen: Low (Niedrig), Medium (Mittel) und High (Hoch). Die Tornado II Sub Mega VT vereint alle Funktionen in einem eleganten und einfach zu bedienenden Gert, das sowohl fr Einsteiger als auch fr fortgeschrittene Dampfer geeignet ist.

    A. AkkuB. VerdampferbasisC. Verdampferkopf CL-Ni (0.2)D. Verdampferkopf CL-Ti (0.4)E. TankF. Mundstck

    A B C D E F

    TW Tornado 2 Sub Mega VT Manual.indd 14-15 08/10/2015 16:52

  • 16 17

    Bedienung Ihrer Tornado II Sub Mega VTBedienung Ihrer Tornado II Sub Mega VT

    Verdampferkopf-Inbetriebnahme:Bei der Erstverwendung eines Verdampferkopfes etwas E-Liquid direkt auf das Heizelement und die umliegende Baumwolle trpfeln hiermit wird sichergestellt, dass das Fllmaterial mit ausreichend E-Liquid durchtrnkt wird und beste Dampfergebnisse erzielt werden knnen.

    Tank befllen:Tornado II Sub Mega VT umdrehen und den Akku und die Verdampferbasis vom Tank abschrauben. Tank am ueren Rand, um die Luftfhrung herum, mit E-Liquid befllen.

    Power Ein/Aus:Power-Taster 5-mal hintereinander drcken; Die LED signalisiert durch 5-maliges Aufblinken die Aktivierung der Tornado II Sub Mega VT. Zum Ausschalten Power-Taster ebenfalls 5-mal hintereinander drcken.

    Dampfen:Power-Taster drcken und inhalieren. Wenn der Taster gedrckt wird, leuchtet die LED des Tasters auf.

    Betriebsmodus wechseln:Wenn das Gert ausgeschaltet ist, Power-Taster lnger gedrckt halten mit dieser Abfolge kann zwischen den Modi VT-Ni/VT-Ti/VW gewechselt werden.

    Leistungsstufe whlen:Wenn das Gert eingeschaltet ist, Power-Taster 3-mal hintereinander drcken und im VW- oder VT-Modus eine Leistungsstufe (Low/Medium/High) nach Prferenz auswhlen.

    TW Tornado 2 Sub Mega VT Manual.indd 16-17 08/10/2015 16:52

  • 18 19

    Bedienung Ihrer Tornado II Sub Mega VTBedienung Ihrer Tornado II Sub Mega VT

    Kurzschlussschutz:Hat die Tornado II Sub Mega VT einen Kurzschluss erkannt und der Power-Taster wurde nicht gedrckt, blinkt die LED 5-mal auf. Erkennt die Tornado II Sub Mega VT beim Drcken des Power-Tasters einen Kurzschluss, blinkt die LED 3-mal auf und die Stromzufuhr zum Verdampfer wird unterbrochen.

    Luftzug einstellen:Durch Drehen der Luftzugregulierung an der Verd