Table of contentsEnterview 5 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Door Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Maximum Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Additional Keypad and Magnetic Lock Wiring . . . . . . . . . . . . . . . . . . . . . . . . . 7Additional Keypad and Yale-release Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Keypad Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Additional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 2
3
123
1 3 2 4
1 3 2 4
23
1
2
3
1
2
3
Enterview 5 Overview� 4 Handsets maximum per-system� 2 Audio-Only handsets maximum per-system� Each handset requires supplied PSU (1 PSU per handset required)� Keypad Camera requires suppIied PSU� Standard Camera requires EVBPS for door release facility� For a voltage-free contact: Keypad Camera requires a12VDC relay (not supplied)
CAT5e cable speci fied for maximum distances
� 100 Meters maximum distance between outdoor station and furthest handset� 10 Meters maximum distance between handset and supplied PSU - Note: 2 pairs of
CAT5e must be used to achieve this distance
1 – Camera 2 – Speaker3 – Call Button
1 – Opens Camera Channel2 – Door Release3 – Call Transfer4 – Opens 2-way Audio
EVH5C-HF
Keypad Camera
Standard CameraEVH5
EVH5AOEVHF10B / EVHF10W
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 3
AC240 AC240Wiring Configuration Standard Camera
Keypad CameraSee additional wiring instructions for Keypad
4
LOCK
LOCK
AC240 AC240
AC240 Keypad PSU provided
1
2
3
4
5
6
Handset PSUs provided
Handset PSUs provided
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 4
NOTE:
J1 AND J2 – DO NOT REMOVE
J3 – ONLY REMOVE FOR MULTIWAYOUTDOOR STATION CONNECTION
5
LOCK
1
2
3
4
5
6
LOCK
AC240
AC240
Keypad PSUprovided
See additional wiring instructions for keypad
AC240 AC240
Handset PSUs provided
Handset Connections
2 Door Wiring Configuration
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 5
6
Maximum WiringConfiguration
AC
240
AC
240
AC
240
AC
240
AC
240
AC
240
LOC
K
See
add
ition
al w
iring
inst
ruct
ions
for
keyp
ad
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 6
7
Additional Keypad and Magnetic Lock Wiring
EGR Ov COM
N.C
EXITBUTTON
EMERGENCYBREAKGLASS
AC240
Keypad PSU provided
*For a voltage-free contact: Keypad requiresand additional 12VDC relay (not supplied)
Back of Keypad camera
–+
MAGLOCK
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 7
8
Additional Keypad and Yale-release Wiring
EGR Ov COM
N.O
EXITBUTTON
AC240
Keypad PSU provided
*For a voltage-free contact: Keypad requiresand additional 12VDC relay (not supplied)
Back of Keypad camera
–+
Yale Release
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 8
9
Keypad CommandsDefault master code: 1234
Entering Programming mode1 Press * then 4 digit master code2 If successful three tones will sound and the LED will flash
Adding user codes1 Enter programming mode2 lnput the code group O1-31 for normal operation, 32-40 for latching mode.3 Enter the 4 digit code, if successful three tones sound if not 2 tones sound.4 Press* to exit
Deleting a user code1 Enter programming mode2 Enter group code O1-403 Press # to delete code4 If successful three tones will sound5 Press * to exit
Deleting a code from an unknown group1 Enter programming mode2 Press # two tones will sound3 lnput 4 digit code to be deleted4 Three tones will sound if successful5 Press * to exit
Deleting all codes1 Enter programming mode2 Press # two tones will sound3 Press # again to hear a further two tones4 Press # seven times to default all codes and settings (the master code will remain)5 The system will resume after five seconds
Changing the master code1 Down powerthe unit2 Hold * and power up the unit, a long tone will sound3 When the tone stops, a short tone will sound and input the new 4 digit
programming code
Set the lock time1 Enter programming2 Enter O03 Enter the lock/delay operation time (O1-99 seconds)4 Press * to exit
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 9
10
Installation GuideEVH5EVH5C
EVH5C-HF / EVHF10W / EVHF10B
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 10
11
Installation GuideEV5 CAMEV5 CCAM
EV5KPCAMEV5CKPCAM
*Recommended installation height 150cm
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 11
Elite Security ProductsUnit 7, Target Park, Shawbank RdLakeside, Redditch B98 8YN
Telephone: 01527 515150email: [email protected]
Technical Speci cation
Additional AccessoriesEV-BPS – 12VDC 2 amp Multi output boxed power supplyEV-EBG – Emergency break glassEV-EXIT – Push to exit buttonEV-ML-250 – Electromagnetic lock
Enterview 5
Power 14.5 DC
Video Output 1-1VP-P 750hm B/W PAL
Operating Temp. -10/55ºC
Consumption 800ma
Dimensions (mm) 205x220x50
Enterview 5C
Power 14.5 DC
Video Output 1-1VP 750hm PAL
Operating Temp. -10/55ºC
Consumption 800ma
Dimensions (mm) 205x220x50
Enterview 5C-HF
Power 14.5 DC
Video Output 1-1VP 750hm PAL
Operating Temp. -10/55ºC
Consumption 800ma
Dimensions (mm) 240x175x38
EVHF10B / EVHF10W
Power 14.5 DC
Video Output 1-1VP 750hm PAL
Operating Temp. -10/55ºC
Consumption 800ma
Dimensions (mm) 340x210x38
Enterview 5 CAM
Power 14.5 DC
Video Output 1-1VP-P 750hm B/W PAL
Min. Illumination 1 Lux
Operating Temp. -10/55ºC
Consumption 150ma
Dimensions (mm) 55x130x40
Enterview 5 C-CAM
Power 14.5 DC
Video Output 1-1VP-P 750hm PAL
Min. Illumination 1 Lux
Operating Temp. -10/55ºC
Consumption 150ma
Dimensions (mm) 55x130x40
Enterview 5 KP
Power 14.5 DC
Video Output 1-1VP-P 750hm B/W PAL
Min. Illumination 1 Lux
Operating Temp. -10/55ºC
Consumption 150ma
Dimensions (mm) 75x190x45
Enterview 5 CKP
Power 14.5 DC
Video Output 1-1VP-P 750hm PAL
Min. Illumination 1 Lux
Operating Temp. -10/55ºC
Consumption 150ma
Dimensions (mm) 75x190x45
Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 12