VIDEO DOOR ENTRY SYSTEM INSTRUCTIONS Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 1

VIDEO DOOR ENTRY SYSTEM INSTRUCTIONS - TLC

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

VIDEO DOOR ENTRY SYSTEM INSTRUCTIONS

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 1

2

Table of contentsEnterview 5 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Door Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Maximum Wiring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Additional Keypad and Magnetic Lock Wiring . . . . . . . . . . . . . . . . . . . . . . . . . 7Additional Keypad and Yale-release Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Keypad Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Additional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 2

3

123

1 3 2 4

1 3 2 4

23

1

2

3

1

2

3

Enterview 5 Overview� 4 Handsets maximum per-system� 2 Audio-Only handsets maximum per-system� Each handset requires supplied PSU (1 PSU per handset required)� Keypad Camera requires suppIied PSU� Standard Camera requires EVBPS for door release facility� For a voltage-free contact: Keypad Camera requires a12VDC relay (not supplied)

CAT5e cable speci fied for maximum distances

� 100 Meters maximum distance between outdoor station and furthest handset� 10 Meters maximum distance between handset and supplied PSU - Note: 2 pairs of

CAT5e must be used to achieve this distance

1 – Camera 2 – Speaker3 – Call Button

1 – Opens Camera Channel2 – Door Release3 – Call Transfer4 – Opens 2-way Audio

EVH5C-HF

Keypad Camera

Standard CameraEVH5

EVH5AOEVHF10B / EVHF10W

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 3

AC240 AC240Wiring Configuration Standard Camera

Keypad CameraSee additional wiring instructions for Keypad

4

LOCK

LOCK

AC240 AC240

AC240 Keypad PSU provided

1

2

3

4

5

6

Handset PSUs provided

Handset PSUs provided

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 4

NOTE:

J1 AND J2 – DO NOT REMOVE

J3 – ONLY REMOVE FOR MULTIWAYOUTDOOR STATION CONNECTION

5

LOCK

1

2

3

4

5

6

LOCK

AC240

AC240

Keypad PSUprovided

See additional wiring instructions for keypad

AC240 AC240

Handset PSUs provided

Handset Connections

2 Door Wiring Configuration

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 5

6

Maximum WiringConfiguration

AC

240

AC

240

AC

240

AC

240

AC

240

AC

240

LOC

K

See

add

ition

al w

iring

inst

ruct

ions

for

keyp

ad

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 6

7

Additional Keypad and Magnetic Lock Wiring

EGR Ov COM

N.C

EXITBUTTON

EMERGENCYBREAKGLASS

AC240

Keypad PSU provided

*For a voltage-free contact: Keypad requiresand additional 12VDC relay (not supplied)

Back of Keypad camera

–+

MAGLOCK

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 7

8

Additional Keypad and Yale-release Wiring

EGR Ov COM

N.O

EXITBUTTON

AC240

Keypad PSU provided

*For a voltage-free contact: Keypad requiresand additional 12VDC relay (not supplied)

Back of Keypad camera

–+

Yale Release

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 8

9

Keypad CommandsDefault master code: 1234

Entering Programming mode1 Press * then 4 digit master code2 If successful three tones will sound and the LED will flash

Adding user codes1 Enter programming mode2 lnput the code group O1-31 for normal operation, 32-40 for latching mode.3 Enter the 4 digit code, if successful three tones sound if not 2 tones sound.4 Press* to exit

Deleting a user code1 Enter programming mode2 Enter group code O1-403 Press # to delete code4 If successful three tones will sound5 Press * to exit

Deleting a code from an unknown group1 Enter programming mode2 Press # two tones will sound3 lnput 4 digit code to be deleted4 Three tones will sound if successful5 Press * to exit

Deleting all codes1 Enter programming mode2 Press # two tones will sound3 Press # again to hear a further two tones4 Press # seven times to default all codes and settings (the master code will remain)5 The system will resume after five seconds

Changing the master code1 Down powerthe unit2 Hold * and power up the unit, a long tone will sound3 When the tone stops, a short tone will sound and input the new 4 digit

programming code

Set the lock time1 Enter programming2 Enter O03 Enter the lock/delay operation time (O1-99 seconds)4 Press * to exit

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 9

10

Installation GuideEVH5EVH5C

EVH5C-HF / EVHF10W / EVHF10B

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 10

11

Installation GuideEV5 CAMEV5 CCAM

EV5KPCAMEV5CKPCAM

*Recommended installation height 150cm

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 11

Elite Security ProductsUnit 7, Target Park, Shawbank RdLakeside, Redditch B98 8YN

Telephone: 01527 515150email: [email protected]

Technical Speci cation

Additional AccessoriesEV-BPS – 12VDC 2 amp Multi output boxed power supplyEV-EBG – Emergency break glassEV-EXIT – Push to exit buttonEV-ML-250 – Electromagnetic lock

Enterview 5

Power 14.5 DC

Video Output 1-1VP-P 750hm B/W PAL

Operating Temp. -10/55ºC

Consumption 800ma

Dimensions (mm) 205x220x50

Enterview 5C

Power 14.5 DC

Video Output 1-1VP 750hm PAL

Operating Temp. -10/55ºC

Consumption 800ma

Dimensions (mm) 205x220x50

Enterview 5C-HF

Power 14.5 DC

Video Output 1-1VP 750hm PAL

Operating Temp. -10/55ºC

Consumption 800ma

Dimensions (mm) 240x175x38

EVHF10B / EVHF10W

Power 14.5 DC

Video Output 1-1VP 750hm PAL

Operating Temp. -10/55ºC

Consumption 800ma

Dimensions (mm) 340x210x38

Enterview 5 CAM

Power 14.5 DC

Video Output 1-1VP-P 750hm B/W PAL

Min. Illumination 1 Lux

Operating Temp. -10/55ºC

Consumption 150ma

Dimensions (mm) 55x130x40

Enterview 5 C-CAM

Power 14.5 DC

Video Output 1-1VP-P 750hm PAL

Min. Illumination 1 Lux

Operating Temp. -10/55ºC

Consumption 150ma

Dimensions (mm) 55x130x40

Enterview 5 KP

Power 14.5 DC

Video Output 1-1VP-P 750hm B/W PAL

Min. Illumination 1 Lux

Operating Temp. -10/55ºC

Consumption 150ma

Dimensions (mm) 75x190x45

Enterview 5 CKP

Power 14.5 DC

Video Output 1-1VP-P 750hm PAL

Min. Illumination 1 Lux

Operating Temp. -10/55ºC

Consumption 150ma

Dimensions (mm) 75x190x45

Enterview 5 Manual_Layout 2 09/10/2012 14:53 Page 12