VITODENS 200 Operating Instructions & User’s Information Manual Vitodens 200-W WB2B Series Wall-mounted, gas-fired condensing boiler For natural gas and liquid propane Heating input 31 to 370 MBH 8.5 to 105 kW Read and save these instructions for future reference. IMPORTANT If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. WARNING Improper installation, adjustment, and/or operation could cause carbon monoxide poisoning resulting in injury or loss of life. This product must be installed and serviced by a professional service technician who is experienced and qualified in hot water boiler installation and gas combustion. WARNING Do not store or use gasoline or other flammable liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS Do not try to light any appliances. Do not touch any electrical switches, do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Please file in Service Binder 5369 299 v1.0 b 08/2009 This trademark is registered with the U.S. Patent and Trademark Office.

Vitodens 200-User Manual

Embed Size (px)

Citation preview

Page 1: Vitodens 200-User Manual

VITODENS 200

Operating Instructions &User’s Information Manual

Vitodens 200-WWB2B SeriesWall-mounted, gas-fired condensing boiler

For natural gas and liquid propaneHeating input 31 to 370 MBH

8.5 to 105 kW

Read and save these instructionsfor future reference.

IMPORTANT

If the information in this manual is not followedexactly, a fire or explosion may result causingproperty damage, personal injury or loss of life.

WARNING

Improper installation, adjustment, and/oroperation could cause carbon monoxidepoisoning resulting in injury or loss of life.

This product must be installed and serviced by aprofessional service technician who isexperienced and qualified in hot water boilerinstallation and gas combustion.

WARNING

Do not store or use gasoline or other flammableliquids in the vicinity of this or any otherappliance.

WHAT TO DO IF YOU SMELL GASDo not try to light any appliances.Do not touch any electrical switches, do notuse any phone in your building.Immediately call your gas supplier from aneighbor’s phone. Follow the gas supplier’sinstructions.If you cannot reach your gas supplier, call thefire department.

Installation and service must be performed by aqualified installer, service agency or the gassupplier.

PleasefileinServiceBinder

5369 299 v1.0 b 08/2009 This trademark is registered with the U.S. Patent and Trademark Office.

Page 2: Vitodens 200-User Manual

Safety, Installation and Warranty Requirements

2

Safety, Installation and Warranty Requirements

Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the instructionslisted below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life. Ensureall requirements below are understood and fulfilled (including detailed information found in the manual subsections).

H Licensed professional heatingcontractorThe installation, service, andmaintenance of this equipment mustbe performed by a licensedprofessional heating contractor.

" Please see sectionentitled “ImportantRegulatory andInstallationRequirements” in theInstallation Instructions.

H Product documentationRead all applicable documentationbefore commencing installation. Storedocumentation near boiler in a readilyaccessible location for reference in thefuture by service personnel.

" For a listing ofapplicable literature,please see sectionentitled “ImportantRegulatory andInstallation Requirements”in the Installation Instructions.

HAdvice to ownerOnce the installation work iscomplete, the heating contractor mustfamiliarize the systemoperator/ultimate owner with allequipment, as well as safetyprecautions/requirements, shut-downprocedure, and the need forprofessional service annually beforethe heating season begins.

HCarbon monoxideImproper installation, service and/ormaintenance can cause flue productsto flow into living space. Flueproducts contain poisonous carbonmonoxide gas.

" For informationpertaining to the properinstallation, service andmaintenance of thisequipment to avoidformation of carbon monoxide, pleasesee the Installation Instructions of theVitodens 200-W Direct Vent System.

H Equipment ventingNever operate boiler without aninstalled venting system. An improperventing system can cause carbonmonoxide poisoning.

HWarrantyInformation contained inthis and related productdocumentation must beread and followed. Failureto do so renders warrantynull and void.

5369299

v1.0

b

Installers must follow localregulations with respect toinstallation of carbon monoxidedetectors. Follow manufacturer’smaintenance schedule of boiler.

WARNING

Page 3: Vitodens 200-User Manual

Index

3

Page

General Information About these Instructions 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety For your Safety 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inform Yourself Getting Started 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Your Vitodens 200-W Boiler 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Your System is Preset at the Factory 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Overview of Controls and Indicators 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Opening the control unit 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Functions 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Heating system with two heating circuits 14. . . . . . . . . . . . . . . . . . . . . . .

Start-up / Shutdown Starting the Heating System 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shutting Down the Heating System 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Starting a heating circuit and DHW heating 16. . . . . . . . . . . . . . . . . . . .

Shutting down a heating circuit and stoppingDHW heating 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Starting DHW heating only 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Stopping DHW heating 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjusting the RoomTemperature

Setting a Permanent Room Temperature 18. . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting normal room temperature 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting a reduced room temperature 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting a time program (switching times) 20. . . . . . . . . . . . . . . . . . . .

Changing the room temperature for a few days only 21. . .

Selecting the holiday program 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Changing the Room Temperature for aFew Hours Only 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting energy saving mode 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting party mode 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting DHW Heating Selecting Constant DHW Heating 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DHW temperature setting 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting a time program (switching times) 26. . . . . . . . . . . . . . . . . . . . .

Selecting automatic mode (if required) 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Setting up an individual time program 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Selecting DHW Heating for a Few Hours Only 29. . . . . . . . . . . . . . .

Selecting DHW heating only once 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Further Adjustments Time and Date 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Language 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjusting the display contrast 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Standard setting 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scanning Options Scanning Information 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Order in which temperatures and operatingconditions can be scanned 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scanning Time Programs 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Central heating time program 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DHW time program 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scanning fault display 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5369299

v1.0

b5369299

v1.0

b

Page 4: Vitodens 200-User Manual

4

Other Settings Changing the Heating Pattern of the Boiler 35. . . . . . . . . . . . . . . . . . . . . .

Rooms are too cold 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rooms are too hot 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

There is no hot water 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The DHW is too hot 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

”Select htg. circuit” flashes in the display 36. . . . . . . . . . . . . . . . . . . . . .

”Fault” flashes in the display 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

The time flashes at the display 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

“Service” is displayed 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

”Remote control” is displayed 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

”Ext. control” is displayed 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

”Ext. program” is displayed 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

“Ext, room t. setpt.” is displayed 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

“Without function.” is displayed 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Service Instructions Service Instructions for Your Heating System 38. . . . . . . . . . . . . . . . .

How to Save Energy How to Save Energy 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

... by heating correctly 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

... with regular maintenance 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

... with effective insulation 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Information Lighting and Operating Instructions 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5: Vitodens 200-User Manual

General Information/Safety

5

About these InstructionsTake note of all symbols and notations intended to draw attention to potential hazards or important product information.These include ”WARNING”, ”CAUTION”, and ”IMPORTANT”. See below.

Warnings draw your attention to thepresence of potential hazards orimportant product information.

Cautions draw your attention to thepresence of potential hazards orimportant product information.

Helpful hints for installation, operationor maintenance which pertain to theproduct.

This symbol indicates that additional,pertinent information is to be found incolumn three.

This symbol indicates that otherinstructions must be referenced.

For your Safety

H Operation

Before operating the boiler, make sureyou fully understand its method ofoperation. Your heating contractorshould always perform the initial start-upand explain the system. Any warranty isnull and void if these instructions are notfollowed.

HWorking on the equipment

All personnel working on the equipmentor the heating system must have theproper qualifications and hold allnecessary licenses.

Ensure main power to equipment,heating system, and all external controlshas been deactivated. Close main gassupply valve. Take precautions in allinstances to avoid accidental activationof power during service work.

HMaintenance and cleaning

Regular inspection and service by aqualified heating contractor is importantto the performance of the ViessmannVitodens 200-W. Neglectedmaintenance impacts on warranty;regular inspection ensures clean,environmentally friendly and efficientoperation. We recommend amaintenance contract with a qualifiedheating contractor.

H Flue gas smell

- Deactivate heating equipment.- Open windows and doors.- Inform your heating contractor.

H Dangerous conditions

- Deactivate main power immediately.- Close gas supply valve.

H Technical information

Literature applicable to all aspects of theVitodens 200-W:- Technical Data Manual- Installation Instructions- Start-up/Service Instructions- Operating Instructionsand User’s Information Manual

Additional applicable literature:- Accessory manuals

5369299

v1.0

b

Indicates an imminently hazardoussituation which, if not avoided, couldresult in death, serious injury orsubstantial product/property damage.

WARNING

Indicates an imminently hazardoussituation which, if not avoided, mayresult in minor injury orproduct/property damage.

CAUTION

IMPORTANT

Page 6: Vitodens 200-User Manual

SafetySafety

6

For your Safety (continued)

H Carbon monoxide

The U.S. Consumer Product SafetyCommission strongly recommends theinstallation of carbon monoxidedetectors in buildings in whichgas-burning equipment is installed.Carbon monoxide (CO) is a colorless,odorless gas, which may be producedduring incomplete combustion of fueland/or when the flame does not receivean adequate supply of combustion air.

Carbon monoxide can cause severepersonal injury or loss of life.

Therefore, carbon monoxide detectorsthat are in compliance with a nationallyrecognized standard (e.g. ANSI/UL2034-2002, CSA 6.19-01) should beinstalled and maintained in buildings thatcontain gas-burning equipment.

Note:Viessmann does not test any detectorsand makes no representation regardingany brand or type of detector.

H For safe operation

We recommend that you frequently:- Check for debris which could obstructthe flow of flue gases. The vent orchimney must not be blocked. Ablocked or partially blocked vent orchimney can cause flue gases to leakinto the structure. Flue gases leakinginto the house can cause injury ordeath. Blocked or partially blockedchimneys must have the blockageremoved by a qualified heatingcontractor.

- Check pressure gage for correctsystem (water) pressure. Check forwater on the floor from the dischargepipe of the pressure relief valve or anyother pipe, pipe joint, valve or airvent.

- Check for moisture, water, orappearance of rust on the flue gaspipes, their joints as well as ventdampers, or side wall vent terminals(if so equipped).

- Ensure that nothing is obstructing theflow of combustion and ventilation airand no chemicals, garbage, gasoline,combustible materials, flammablevapors and liquids are stored (noteven temporarily) in the vicinity of theboiler.

- Do not allow unsupervised childrennear the boiler.

Service/inspection of the boiler and thesystem is recommended once a year.Maintenance, service and cleaning arespecified in the Installation Instructions.

Before the heating season begins, it isrecommended that the boiler and burnerbe serviced by a qualified heatingcontractor. Service contracts may beestablished through gas suppliers orother licensed contractors in your area.

5369299

v1.0

b5369299

v1.0

b

As there are no user-serviceable partson the boiler, burner or control, theend-user must not perform serviceactivities or adjustments of any kind onsystem components. Failure to heedthis warning can cause propertydamage, severe personal injury, or lossof life.

WARNING

Improper installation, adjustment,service, or maintenance can cause flueproducts to flow into living space. Flueproducts contain poisonous carbonmonoxide gas which can cause nauseaor asphyxiation resulting in severepersonal injury or loss of life.

WARNING

Should overheating occur or the gassupply fail to shut off, do notdisconnect the electrical supply to thepump. Instead, shut off the gas supplyat a location external to the appliance.

CAUTION

The operator/ultimate owner is requiredto have the heating boiler, burners, andcontrols checked, as a minimum onceper year, by the original installer or by acompetent heating contractor familiarwith the equipment. Defects must becorrected immediately.

WARNING

Do not use this boiler if any part hasbeen under water. Immediately call aqualified heating contractor to inspectthe boiler and to replace any part of thecontrol system and any gas controlwhich has been under water.

CAUTION

Page 7: Vitodens 200-User Manual

Safety

7

For your Safety (continued)

Frozen water pipe hazard

Your heating boiler is designed to providea warm and comfortable livingenvironment. It is not designed to ensureagainst freezing of water pipes.The boiler is equipped with several safetydevices that are designed to shut downthe boiler and to prevent it from restartingin the event of various unsafe conditions.

If your boiler remains off for an extendedperiod of time during cold weather, waterpipes may freeze and burst, resulting inextensive water damage and conditions inwhich mold could grow. Certain molds areknown to cause respiratory problems, aswell as to pose other serious health risks.In case of water damage, immediatemeasures should be taken to dry outaffected areas as quickly as possible toprevent mold from developing.

If your home will be unattended for anextended period of time during coldweather, you should...

H Shut off the water supply to thebuilding, drain the water pipes and addan antifreeze for potable water to draintraps and toilet tanks. Open faucetswhere appropriate.

Or..

H Have someone check the buildingfrequently during cold weather and call aqualified service agency if required.

Or...

H Install a reliable remote temperaturesensor that will notify somebody offreezing conditions within the home.

5369299

v1.0

b

Failure to protect against frozen pipescould result in burst water pipes,serious property damage and/orpersonal injury. Boiler may shut down.Do not leave your home unattended forlong periods of time during freezingweather conditions without turning offthe water supply and draining waterpipes or otherwise protecting againstthe risk of frozen pipes.

WARNING

Page 8: Vitodens 200-User Manual

Safety

8

For your Safety (continued)

If you notice fire coming from theappliance, call the fire departmentimmediately! Do not attempt to extinguishthe fire unless qualified to do so.

Installation area conditions

H Ensure ambient temperatures are higherthan 32°F / 0°C and lower than104°F / 40°C.

H Prevent the air from becomingcontaminated by halogenatedhydrocarbons (e.g. as contained in paintsolvents or cleaning fluids) andexcessive dust (e.g. through grinding orpolishing work).Combustion air for the heating process,and ventilation of the boiler room mustbe free of corrosive contaminants. Tothat end, any boiler must be installed inan area that has no chemical exposure.The list to the right indicates the main,currently known sources.

H Avoid continuously high levels ofhumidity (e.g. through frequent drying oflaundry).

H Never close existing ventilationopenings.

Replacement components, spare and wearparts

Components which are not tested withthe heating system may damage theheating system, or affect its functions.Installation or replacement may only becarried out by a qualified heatingcontractor.

Sources of combustion and ventilation aircontaminants

Areas likely to contain contaminants:

H New building constructionH Swimming poolsH Remodelling areas, hobby roomsH Garages with workshopsH Furniture refinishing areasH Dry cleaning/laundry areas andestablishments

H Auto body shopsH Refrigeration repair shopsHMetal fabrication plantsH Plastic manufacturing plantsH Photo processing plantsH Beauty salons

Products containing contaminants:

H Chlorine-type bleaches, detergents andcleaning solvents found in householdlaundry rooms

H Paint and varnish removersH Hydrochloric acid, muriatic acidH Chlorine-based swimming pool chemicalsH Spray cans containingchlorofluorocarbons

H Chlorinated waxes and cleanersH Cements and gluesH Refrigerant leaksH Calcium chloride used for thawingH Sodium chloride used for watersoftening salt

H Permanent wave solutionsH Adhesives used to fasten buildingproducts and other similar items

H Antistatic fabric softeners used inclothes dryers

5369299

v1.0

b

Fire causes a risk of burns andexplosion!H Shut down the boilerH Close fuel shut-off valvesH Use a tested fire extinguisher, class

ABC.

WARNINGIncorrect ambient conditions can lead todamage to the heating system and putsafe operation at risk.

WARNING

IMPORTANT

Page 9: Vitodens 200-User Manual

Inform Yourself

9

Getting Started...

The timer of the control unit switches between ”normal room temperature” and”reduced room temperature” at the required times.

1. Normal room temperaturefor the times you spend at home andrequire a comfortably warm roomtemperature (e.g. 68ºF / 20ºC).

2. Reduced room temperaturefor the times you are away fromhome. To save energy,a lower temperature is typicallyselected (e.g. 57ºF / 14ºC).

Times and duration of the two roomtemperatures can be set on theprogramming unit of your control.The temperature settings for both the”normal room temperature” and”reduced room temperature” can beset according to your personalpreference.

The timer of the control unit switches domestic hot water production on and off atthe required times.

1. Domestic hot water heating can beset to take placeduring the times you spend at homeand require hot water for your dailyDHW requirements (e.g. forshowering).

2. Domestic hot water heating can beset not to take placefor the times you spend sleeping, forexample.

Times and duration of the domestic hotwater production period can be set onthe programming unit of your control.

You may select a DHW temperaturesetting based on your personalpreference of up to 140ºF / 60ºC.

The domestic hot water recirculationpump (if installed) ensures thatdomestic hot water is readily availablewhen domestic hot water is drawn.

5369299

v1.0

b

Page 10: Vitodens 200-User Manual

Inform Yourself

10

Your Vitodens 200-W Boiler

Please ask your heating contractor to check off the appropriate box ( ).

j Vitodens 200-Wwithout domestic hot water tank

The control unit activates anddeactivates space heating andsupplies rooms with heat.

j Vitodens 200-Wwith separate domestic hot watertank

Domestic hot water heating haspriority over space heating. Thecontrol unit switches automatically tospace heating when the presetdomestic hot water temperature isreached.

Your System is Preset at the Factory

The control unit is preset at the factoryfor standard operation. Your heatingsystem is therefore ready to use:

H Between 06:00 and 22:00 hrs. thesystem provides central heating withstandard room temperature.

H DHW will be heated between 05:30and 22:00 hrs. DHW will be heated tothe set temperature subject to a DHWtank being installed. The DHWcirculation pump is switched ON (ifconnected to the control unit).

H Between 22:00 and 06:00 hrs. thesystem provides central heating withthe reduced room temperature (set to3ºC, frost protection).

H Between 22:00 and 05:30 hrs. theDHW tank temperature will not beboosted. The DHW circulation pump isswitched OFF (if connected to thecontrol unit).

H The system automatically changesover between summer and wintertime.

You may change the factory settings inaccordance with personal requirements.

Note:All data is saved in case of powerfailure.

Press button ”D” to reset theswitching times to their factorydefault settings.Please note that this will reset allaltered values to their original factorydefault setting.

5369299

v1.0

b

Page 11: Vitodens 200-User Manual

Inform Yourself

11

Overview of Controls and Indicators

You can change all settings for your heating system, centrally, at the control unit. You may also make such adjustments forthe respective heating circuits at the remote control unit, if your system is equipped with such a unit.

See the remote controloperating instructions.

Opening the control unit

A CoverB Control unit flap (open to make

adjustments)

5369299

v1.0

b

B A

Lift cover A and pivot control unit flapB down. All boiler controls are locatedbehind the control unit flap.

Page 12: Vitodens 200-User Manual

Inform Yourself

12

Overview of Controls and Indicators (continued)

Functions

A Time program for central heatingB Time program for DHW heatingC Holiday programD InformationE Standby modeF DHW onlyG Central heating and DHWH Normal room temperatureK Energy saving mode ON / OFF

L Party mode ON / OFFM Factory default settings buttonN Confirmation buttonO Adjustment buttonsP DHW temperatureR Emission test function (only for

heating engineers)S Reduced room temperatureT Time / date

5369299

v1.0

b

A

BC

+

OK

T S R P O N M L K

HED

+

F G

140

Boiler temp.

ºF

MO

s A

_

Page 13: Vitodens 200-User Manual

Inform Yourself

13

Overview of Controls and Indicators (continued)

A Pressure gaugeB Fault display (red)C Operating status display (green)

D Reset buttonE ON / OFF switch

These symbols are not always displayed, but appear subject to the system version and the operating state.

e Risk of freezings Central heating with normal

room temperaturem Central heating with reduced

room temperaturep Heating circuit pump ON| Mixing valve “OPEN”~ Mixing valve “CLOSED”w DHW pump ON

p DHW heating via solar heatingsystem (accessories)

A Burner ONu Time adjustment displayS Emissions test ONE Burner fault (appears instead of

the day of the week)1 In case of two heating circuits:

Selected heating circuit

5369299

v1.0

b

4

+

?OK

0

12

3

0

+RESET

s

?F

A140Mo

Boiler temp.

C D EA B

8888 :88 :Mo

Boiler temp.

1 ºCF

esmp(wp upA

uS

h

Page 14: Vitodens 200-User Manual

Inform Yourself

14

Overview of Controls and Indicators (continued)

Heating system with two heating circuits

When two heating circuits have beenconnected to your heating system,select the heating circuit to which thesetting should apply before makingadjustments at the control unit.

150Mo

Boiler temp.

2ºF

e mp w A

Press the following keys:1.⊕ “1r“ flashes on the display.

2. for selecting heating circuit A1(heating circuit without mixingvalve).

Or..

3.⊕ for heating circuit M2 (heatingcircuit with mixing valve)“2r“ flashes on the display.

4. for selecting heating circuit M2(heating circuit mixing valve).

5. Continue with the requiredadjustment (e.g. activate rotaryselector “ts“ or press theappropriate key for the relevantfunction).

Note:“Select heating circuit” will be displayedshould you begin making adjustmentsprior to selecting the relevant heatingcircuit.

Note:After approximately 4 seconds or if youpress again, the following will bedisplayed:

The figure in front of the day indicateswhich heating circuit has been selected.

Note:If “Remote control” flashes in thedisplay, make the relevant adjustmentat the remote control.

See the remote controloperating instructions.

5369299

v1.0

b

Page 15: Vitodens 200-User Manual

Start-up / Shutdown

0

1

2

3

4

Kesseltemperatur?CMo

+

?OK

+

C

A

B

15

Starting the Heating System

1. Check the pressure of the heatingsystem on the pressure gauge A: Ifthe pressure is below 12 psi / 0.8 barthe system pressure is too low.Notify your heating contractor if thesystem pressure is too low.

2. For room air dependent operation:Check whether the ventilationapertures in the boiler room are openand unobstructed.

Note:For room air dependent operation:This boiler requires fresh air for safeoperation. The boiler must be ventedand supplied with air and exhaustvents.

3. Open gas shut-off valve B.

4. Switch ON the power supply, (e.g. atthe breaker or electrical disconnectswitch. Energize power / pumpmodule).

5. Switch ON the heating system ON /OFF switch “8” C; the operatingstatus is indicated (ON indicator) bythe green LED and the boiler watertemperature will appear in thedisplay.

5369299

v1.0

b

Page 16: Vitodens 200-User Manual

Start-up / Shutdown

16

Shutting Down the Heating System

If you do not want to use your heatingsystem temporarily, (e.g. during yoursummer holidays), switch to stand-byoperation (see ”Shutting down a heatingcircuit and stopping DHW heating”).

Note:The circulation pumps are briefly startedevery 24 hours to prevent them fromseizing up.

If you do not want to use your heatingsystem for a long period (severalmonths), you should shut down thesystem.We advise you to contact your heatingcontractor before shutting down theheating system for long periods. Yourheating contractor will take anynecessary action, (e.g. for frostprotection of the system or to safeguardthe heat exchanger surfaces).

1. Switch the main ON / OFF switch“8” OFF.

2. Close the gas shut-off valve.

3. Turn off the power supply switch ordisconnect power / pump module.The power supply to the system isnow switched off.There is no frost protection.

Note:All control settings are retained.

Starting a heating circuit and DHW heating

You want to heat your rooms and haveDHW available.

Press “rw“ for “Heating & DHW”.

If “Select heating circuit” is displayedand “1r“ flashes:H Select that heating circuit with ⊕ / ⊝,to which the adjustment should apply.

H Confirm twice with .

Press “rw“ for “Heating & DHW”again.

H Central heating will be provided withnormal or reduced room temperature(frost protection) according to the settime program. Standard setting: from06:00 to 22:00 hrs. with the normalroom temperature, otherwise with thereduced room temperature.

H DHW heating (if a DHW tank orinstantaneous water heater isinstalled) and DHW circulation pumprunning (if connected to the controlunit) according to the selected timeprogram. Standard setting: from05:30 to 22:00 hrs., DHW is heatedto the selected set temperature andthe DHW circulation pump is switchedON.

H Frost protection for the boiler and theDHW tank is enabled.

Note:“rw“ button illuminates:H Symbol ”s” appears during centralheating with normal roomtemperature.

H Symbol “m” appears during centralheating with a reduced roomtemperature above 37ºF / 3ºC.

5369299

v1.0

b

Page 17: Vitodens 200-User Manual

Start-up / Shutdown

17

Shutting Down the Heating System (continued)

Shutting down a heating circuit and stopping DHW heating

You do not want to heat your rooms orhave DHW available.

Press “9“ for “Standby mode”.

If “Select heating circuit” is displayedand “1r“ flashes:H Select the heating circuit with ⊕ / ⊝,to which the adjustment should apply.

H Confirm twice with .H Press “9“ again for “Standby mode”.

Standby mode:H Central heating is disabled for theselected heating circuit.

H No DHW heating.H Frost protection for the boiler and theDHW tank is enabled.

Note:The circulation pump is briefly startedevery 24 hours to prevent it fromseizing up.

Starting DHW heating only

You do not want to heat your rooms buthave DHW available.

Press “w“ for “DHW only”.

If “Select heating circuit” is displayedand “1r“ flashes:H Select the heating circuit with ⊕ / ⊝,to which the adjustment should apply.H Confirm twice with .Press “w“ for “DHW only” again.

H Central heating is disabled for theselected heating circuit.

H DHW heating (if a DHW tank orinstantaneous water heater isinstalled) and DHW circulation pump(if connected to the control unit) ONaccording to the set time program.Standard setting: from 05:30 to22:00 hrs., DHW is heated to theselected set temperature and theDHW circulation pump is switchedON.

H Frost protection for the boiler and theDHW tank is enabled.

Note:If “w“ is illuminated and DHW heatingis enabled in accordance with theselected time program, then “w“ will bedisplayed.

Stopping DHW heating

You want to heat your rooms but notmake DHW available.

Set the DHW temperature to 50ºF /10ºC (see page 25).

5369299

v1.0

b

Page 18: Vitodens 200-User Manual

Adjusting the Room Temperature

18

Setting a Permanent Room Temperature

Observe the following points if yourheating circuit should provide centralheating.

H “Heating & DHW” “rw” must beilluminated, otherwise press “rw”.

If “Select heating circuit” is displayedand “1r“ flashes:,- Select the heating circuit with ⊕ / ⊝,to which the central heating shouldapply.

- Confirm twice with .- If “rw” does not illuminate, press“rw” again.

H You can select the normal roomtemperature “ts“ (for day) and thereduced room temperature (for night)with “tm”.

H The timing of when your heatingcircuit operates to provide centralheating with normal or reduced roomtemperature depends on the settingsof the time program (see page 20).

- If no time phases are selected, centralheating will be enabled for the wholeday at reduced room temperature.

- If one or more time phases areselected, central heating will beenabled for those times with normalroom temperature.

You can scan the time program, (seepage 33).For changing the time program, (seepage 20).

Selecting normal room temperature

Select the required temperature for the“Normal room temp.” with selector dial“ts”.

68s

Normal room temp.ºF

If “Select htg. circuit” is displayed and“1r” flashes:H Select the heating circuit with ⊕ / ⊝,to which the central heating shouldapply.

H Confirm twice with .H Set the required temperature for“Normal room temp.” with selector dial“ts”.

5369299

v1.0

b

+

Page 19: Vitodens 200-User Manual

Adjusting the Room Temperature

19

Setting a Permanent Room Temperature (continued)

Selecting a reduced room temperature

Red. room temp.ºF

57m

Press the following buttons:1. tm for “Red. room temp.”, the

current temperature will flash.

If “Select htg. circuit” isdisplayed and “1r“ flashes:H Select the heating circuitwith ⊕ / ⊝, to which thecentral heating should apply.

H Confirm twice with .H tm again for the “Red. roomtemp.”, the currenttemperature selection willflash.

2.⊕/⊝ for the required temperature.

If “Select htg. circuit” isdisplayed and “1r“ flashes:

3. to confirm; the temperature nolonger flashes and is saved.

4. to exit the setting menu.

Note:When setting the reduced roomtemperature to 37ºF / 3ºC, “Frostprotection” will be displayed.

5369299

v1.0

b

Page 20: Vitodens 200-User Manual

Adjusting the Room Temperature

20

Setting a Permanent Room Temperature (continued)

Selecting a time program (switching times)

For central heating, up to four changes can be made between normal and reducedroom temperature (four time phases). At the factory, time phase 1 is set for everyday from 06:00 to 22:00 hrs., ie. during that time, all rooms are heated to thenormal room temperature. You can set the time programs the same for every day orfor each day of the week individually.When setting time programs, bear in mind that your heating system requires sometime to heat the rooms to the required temperature.For a sequence of steps to delete a time phase, (see page 21).Steps for selecting a time program:

Central heating time prog.

1-7

Central heating time prog.

Mo

Press the following keys:

1.ur for “Htg. time program”.

If “Select htg. circuit” isdisplayed and “1r“ flashes:H Select the heating circuitwith ⊕ / ⊝, to which thecentral heating should apply.

H Confirm twice with .H “ur” again for the“Heating time program”.

2.⊕/⊝ until “1-7” is displayed, if youwant to set up identical timephases for every day.

Or..

3.⊕/⊝ until “Mo”, “Tu” etc. isdisplayed, if you want to set updifferent time phases for theday displayed.

4. to confirm; “Htg. timer 1”will then be displayed.

5. to confirm; “Htg. cycle 1 On”will then be displayed.

6.⊕/⊝ for the heating phase startingpoint.

7. to confirm; “Htg. cycle 1 Off”will then be displayed.

8.⊕/⊝ for the heating phase end point.

9. to confirm; “Htg. cycle 2 On”will then be displayed.

10. Proceed for adjusting the start andend of heating phases 2 to 4 asdescribed under steps 6 to 8.

Note:If you want to terminate the timeprogramming early, press “ur“againand confirm with .

Note:If different time phases are set forindividual days and you want to returnto identical time phases for every day,press when “1-7” is displayed. Alltime phases are returned to their originalcondition.

Note:Press if you want to skip a timephase.

5369299

v1.0

b

Page 21: Vitodens 200-User Manual

Adjusting the Room Temperature

21

Setting a Permanent Room Temperature (continued)

Selecting a time program (switching times) (continued)

Heating phase 2 OFF

1-7 - - : - -

Press the following buttons if you wantto delete a time phase:

1.ur for “Htg. time program”.

If “Select htg. circuit” isdisplayed and “1r“ flashes:H Select the heating circuitwith ⊕ / ⊝, to which thecentral heating should apply.

H Confirm twice with .H “ur” again for the“Heating time program”.

2. until the required “Htg. cycle 1Off” is displayed.

3.⊕/⊝ until “ - - : - -” is displayed forthe end time.

4. to confirm; until the boilerwater temperature is displayed.

Changing the room temperature for a few days only

The following energy saving options areavailable for times, when you are not athome:

H You can completely shut down centralheating by pressing 9 (standbymode).

Or..

H You can set the central heating tominimum energy consumption (e.g. toprevent house-plants from sufferingthrough cold). For this, select the“Holiday program” j.During the holiday program, all heatingcircuits are heated with the selected“Red. room temp.”, but there will beno DHW heating.

5369299

v1.0

b

Page 22: Vitodens 200-User Manual

Adjusting the Room Temperature

22

Setting a Permanent Room Temperature (continued)

Selecting the holiday program

The selected time program will beenabled at the departure and returndays.

Departure date

Sa 19;02;05

Return date

We 23;02;05

Press the following keys:

1.j for “Holiday program”.

Or..

2. for “Departure date” (thecurrent date is displayed).

3.⊕ for the date of the requireddeparture day.

4. to confirm; “Return date”(adate following that of thedeparture day) will bedisplayed.

5.⊕ for the date of the requiredreturn day.

6. to confirm.

7. The room temperature during theholiday program is the selectedreduced room temperature (see page19).If you want to change thistemperature:H Press “tm”.

If “Select htg. circuit” is displayedand “1r“ flashes:,- Select the heating circuit with ⊕ /⊝, to which the central heatingshould apply.

- Confirm twice with .- Press “tm” again.

H Select the required value with ⊕/⊝.H Press to confirm; the temperatureno longer flashes and is now saved.

Note:After approximately 4 sec. “Departuredate” will be displayed. Press j againif you want to terminate setting aholiday program early.

Note:This change generally applies to thereduced room temperature and must bemodified again, if required, after theholiday program ends.

Ending holiday program:H The holiday program terminatesautomatically on the day of return.H Press j again if you want toterminate the holiday program earlyand confirm “Delete? Yes” with .

5369299

v1.0

b

Page 23: Vitodens 200-User Manual

Adjusting the Room Temperature

23

Changing the Room Temperature for a Few Hours Only

The following functions enable you tochange your room temperature forseveral hours, without permanentlyaltering your control settings.

H You want to leave your home and,according to the time program, centralheating with normal roomtemperature is currently selected. Tosave energy, you can reduce thenormal room temperature with“Energy saving mode” û .

H You want to heat spontaneously withthe normal room temperature andprovide DHW (e.g. when guestsunexpectedly stay longer in theevening). For this, select “Partymode” “g” (see page 24).

Selecting energy saving mode

In energy saving mode, the normal room temperature will be reduced automatically.Energy saving mode ends automatically with the next change to central heatingwith “Red. room temp.”.

Economy mode1.û for “Energy saving mode”.

If “Select htg. circuit” is displayedand “1r“ flashes:,- Select the heating circuit with⊕ / ⊝, to which the adjustmentshould apply.

- Confirm twice with .- “û” again for “Energy savingmode”.

2. Ending energy saving modeIf you want to terminate energysaving mode early, press “û”.

If “Select htg. circuit” is displayedand “1r“ flashes:,- Select the heating circuit with ⊕ /⊝, to which the adjustment shouldapply.

- Confirm twice with .- Press “û” again.

5369299

v1.0

b

Page 24: Vitodens 200-User Manual

Adjusting the Room Temperature

24

Changing the Room Temperature for a Few Hours Only (continued)

Selecting party mode

Party mode

ºF68

H Central heating will be enabled at anytemperature you select (partytemperature).

H The DHW will be boosted to the settemperature.

H The DHW circulation pump isswitched ON (if installed).

Press the following keys:

1.g for “Party mode”; the value ofthe party temperature flashes.

If “Select htg. circuit”; isdisplayed and “1r“ flashes:H Select the heating circuitwith ⊕ / ⊝, to which theadjustment should apply.

H Confirm twice with .H “g” again for “Party mode”;the party temperature flashes.

2.⊕/⊝ for the required temperature, ifyou want to change the roomtemperature.

3. to confirm; the temperature nolonger flashes and is saved.

4. to exit the setting menu.

5. Ending party modeH Party mode ends automatically withthe next changeover to central heatingwith normal room temperature, butno later than after 8 hours.

H If you want to terminate party modeearly, press “g” again.

If “Select htg. circuit” is displayedand “1r“ flashes:,- Select the heating circuit with ⊕ /⊝, to which the adjustment shouldapply.

- Confirm twice with .- Press “g” again.

5369299

v1.0

b

Page 25: Vitodens 200-User Manual

Selecting DHW Heating

25

Selecting Constant DHW Heating

Observe the following points if youwant to enable DHW heating:

1. Set “Htg. + DHW” “rw“ or “DHWonly” “w“ for the selected heatingcircuit.

Check:“rw“ or “w“ must be illuminated,otherwise press “rw“ or “w“.

If “Select htg. circuit” is displayedand “1r“ flashes:,H Select the heating circuit with ⊕ /⊝, to which the adjustment shouldapply.

H Confirm twice with .H “rw“ or “w“ must be illuminated,otherwise press “rw“ or “w“.

2. The timing of when DHW heating isenabled and when the DHWcirculation pump runs, depends onthe settings of the time program (seepage 26).You can scan the time programs (seepage 33).

Note:You can adjust the DHWtemperature. See “DHW temperaturesetting” section.

For changing the time program, (seepage 26).

DHW temperature setting

Set DHW temperature

ºF122

w

Press the following keys:

1. tw for “DHW temp. setpt.”; thecurrent temperature will flash.

2.⊕/⊝ for the required temperature.

3. to confirm; the temperature nolonger flashes and is saved.

5369299

v1.0

b

Page 26: Vitodens 200-User Manual

Selecting DHW Heating

26

Selecting Constant DHW Heating (continued)

Selecting a time program (switching times)

Heating system without DHWrecirculation pumpDHW can be enabled / disabled up tofour times per day (four time phases).Automatic mode is set in the timeprogram in the factory. That meansDHW heating is enabled in parallel tothe central heating program of the firstavailable heating circuit, but starts30 min. earlier (from 05:30 to22:00 hrs.).Should you not wish to operate inautomatic mode, you can also set upindividual time programs. You can selectidentical time programs for every day orindividual programs for each day.When setting time programs, bear inmind that your heating system requiressome time to heat the DHW tank to therequired temperature.For time programming steps, (see pages26 and 27). For a sequence of steps todelete a time phase, (see page 28).

Heating system with DHW recirculationpumpThe DHW recirculation pump transportshot water through a circuit between theDHW tank and the draw-off points todeliver DHW to the taps as quickly aspossible.DHW heating and the DHW recirculationpump can be enabled / disabled up tofour times per day (four time phases).Automatic mode is set in the timeprogram at the factory. That meansDHW heating and the DHW recirculationpump are activated in parallel to thecentral heating program of the firstavailable heating circuit, but starts 30min. earlier (from 05:30 to 22:00 hrs.).Should you not wish to operate inautomatic mode, you can also set upindividual time programs. You can selectidentical time programs for every day orindividual programs for each day.When setting time programs, bear inmind that your heating system requiressome time to heat the DHW tank to therequired temperature.Also, enabling the DHW recirculationpump is only sensible for those timeswhen DHW is actually drawn.For time programming steps, (see pages26 and 27). For a sequence of steps todelete a time phase, (see page 28).

Selecting automatic mode (if required)

Press the following keys:

1.uw for “DHW time program”.

2.⊕/⊝ to select “DHW timeprogram”, or “Recirc. pumptime program”.

3. to confirm.

4.⊕/⊝ for “Automatic?”, if“Automatic?” is not yetdisplayed.

5. to confirm.

5369299

v1.0

b

Page 27: Vitodens 200-User Manual

Selecting DHW Heating

27

Selecting Constant DHW Heating (continued)

Setting up an individual time program

The following explains the setting up of a time program using DHW heating “uw”as an example. For the DHW recirculation pump time program, proceed as describedabove, after you have selected “Recirc. pump time program”.

DHW time prog.

1-7

DHW time prog.

Mo

Press the following keys:

1.uw for “DHW time program.”.

Note:If you want to terminate the timeprogramming early, press “uw”again and confirm with .

2.⊕/⊝ to select “DHW timeprogram.”, or “Recirc. pumptime program.”.

3. to confirm.

4.⊕/⊝ for “Individual?”, if Individual?”is not yet displayed.

5. to confirm.

6.⊕/⊝ until “1-7” is displayed, if youwant to set up the same timephases for every day.

Or..

7.⊕/⊝ until “Mo”, “Tu” etc. isdisplayed, if you want to setdifferent time phases for thedisplayed day.

8. to confirm; “DHW timer 1” willthen be displayed.

9. to confirm; “DHW timer 1 ON”will then be displayed.

10.⊕/⊝for DHW phase starting point.

11. to confirm; “DHW cycle 1 Off”will be displayed.

12.⊕/⊝for DHW phase end point.

13. to confirm; “DHW cycle 2 On”will then be displayed.

14. Proceed for setting the start andend of DHW phases 2 to 4 asdescribed in steps 9 to 11.

Note:If different time phases are set forindividual days and you want toreturn to identical time phases forevery day, press when “1-7” isdisplayed.All time phases are returned to theiroriginal delivered condition.

Note:Press ⊕ if you want to skip a timephase.

5369299

v1.0

b

Page 28: Vitodens 200-User Manual

Selecting DHW Heating

28

Selecting Constant DHW Heating (continued)

Setting up an individual time program (continued)

DHW phase 2 OFF

1-7 - - : - -

Press the following keys if you want todelete a time phase:

1.uw for “DHW time program”.

2. until the required “DHW phaseOff” is displayed.

3.⊝ until “- - : - -” is displayed forthe end time.

4. to confirm; until the boilerwater temperature is displayed.

5369299

v1.0

b

Page 29: Vitodens 200-User Manual

Selecting DHW Heating

29

Selecting DHW Heating for a Few Hours Only

The following functions enable you to heat DHW for several hours, withoutpermanently altering your control settings. For this, select “Party mode” “g”.During party mode, the DHW recirculation pump is active and central heatingoperates with the party temperature. Set the party temperature to 39.2ºF / 4ºC, ifyou require no central heating (e.g. in summer).

Party mode

ºF68

Press the following keys:

1.g for “Party mode”; the value ofthe party temperature flashes.

If “Select htg. circuit”; isdisplayed and “1r“ flashes:H Select that heating circuitwith ⊕ / ⊝, to which theadjustment should apply.

H Confirm twice with .H “g” again for “Party mode”;the party temperature flashes.

2.⊕/⊝ for the required temperature, ifyou want to change the roomtemperature.

3. to confirm; the temperature nolonger flashes and is saved.

4. to exit the setting menu.

5. Ending party modeH Party mode ends automatically withthe next changeover to centralheating with normal roomtemperature, but no later than after8 hours.

H If you want to terminate partymode early, press “g” again.

If “Select htg. circuit” is displayedand “1r“ flashes:,H Select that heating circuit with⊕ / ⊝, to which the adjustmentshould apply.

H Confirm twice with .H Press “g” again

5369299

v1.0

b

Page 30: Vitodens 200-User Manual

Selecting DHW Heating

30

Selecting DHW Heating for a Few Hours Only (continued)

Selecting DHW heating only once

The following function enables you to heat DHW once, without permanently alteringyour settings. For this, select “Party mode” “g”.

Party mode

ºF68

The following function enables you toheat DHW once, without permanentlyaltering your settings. For this, select“Party mode” “g”.

Precondition:H Not in “Standby mode” “9” and notin the “Holiday program” “j”.

H The DHW temperature must be belowthe set value.

Press the following keys:

1.g for “Party mode”; the value ofthe party temperature flashes.

If “Select htg. circuit”; isdisplayed and “1r“ flashes:H Select that heating circuitwith ⊕ / ⊝, to which theadjustment should apply.

H Confirm twice with .H “g” again for “Party mode”;the party temperature flashes.

2. to confirm; DHW heatingbegins.

3. After approximately 10 sec., press“g” again.

5369299

v1.0

b

Page 31: Vitodens 200-User Manual

Further Adjustments

31

Time and Date

Date and time are factory-set and may be changed manually. During commissioning,or after prolonged time out of use, it may be necessary to set the time and date.

Time

u09:05

Date

19;02;05Sa

Note:Summer/winter time will beautomatically changed over.Press the following keys:

1.uý for “Time”.

2.⊕/⊝ for the required time.

3. to confirm;”Date” will then bedisplayed.

4.⊕/⊝ for the required date.

5. to confirm.

Note:Summer/winter time will beautomatically changed over.

Language

Outdoor temp.

ºF68i

English

i

Press the following keys:

1.i “Outdoor temp.”will bedisplayed.

2.⊝ for the required language.

3. to confirm.

Adjusting the display contrast

Open the programming unit flap. Pressand simultaneously adjust the

contrast with ⊕ or ⊝.

Standard setting

All modified values are reset to theirfactory settings by pressing “D”.

5369299

v1.0

b

Page 32: Vitodens 200-User Manual

Scanning Options

32

Scanning Information

Subject to the connected components and settings you have made, you can scanthe actual temperatures and operating conditions.

Press the following keys:

Outdoor temp.ºF

68i

1.i for example, “Outdoor temp.”may be displayed.

If “Select htg. circuit”; isdisplayed and “1r“ flashes:H Select that heating circuitwith ⊕ / ⊝, to which theadjustment should apply.

H Confirm twice with .H Press i again.

2.⊕/⊝ for further scanning of the list.

3.i to end scanning.

Order in which temperatures and operating conditions may be scanned

You can scan various current temperatures and operating status informationdepending on the system components and the settings.

H Subscriber no. - in connection withother control units

H Holiday program - (if entered) withdates of departure and return

H Outdoor temperatureH Boiler water temperatureH Flow temperature - for heating circuitwith mixing valve

H Normal room temp. - set valueH Room temperature - actual value onlyif a remote control unit is connected

H Ext. Set room temp. - only if externalhook-up has taken place

H DHW temperature - DHW temperatureH Solar DHW temp. - DHW temperaturein solar mode (if used)

H Collector temperature - only if a solarheating system is connected

H Common flow temp. - common flowtemperature for systems with low lossheader

H Burner*1 - burner hours runH Burner starts*1

H Solar energy - display in kWh (only if asolar heating system is connected)

H TimeH DateH Burner ON / OFFH Int. pump ON / OFF (boiler pump)H Int. output ON / OFF - for internalconnection extension

H Heating pump ON / OFF - for externalheating circuit pump for heating circuitA1 (pump 20A)

H Tank pump ON / OFF (pump 21)H C pump ON / OFF - DHW recirculationpump (pump 28)

H Central fault m. ON / OFF - centralfault message (output 50)

HMixing valveMixing valve open - fully openMixing valve - intermediate positionMixing valve closed - fully closed

H Solar circuit pump ON / OFF (notused)

H Solar circuit pump ...hrs. - solar circuitpump hours run (not used)

H Language

*1 To reset to “0”: Press D and confirmwith .

5369299

v1.0

b

Page 33: Vitodens 200-User Manual

Scanning Options

33

Scanning Time Programs

Central heating time program

Press the following keys:

1.ur+i press and hold downsimultaneously for centralheating time program; theset time phases will then bedisplayed on a time slotgraphic.

If “Select htg. circuit” is displayedand “1r“ flashes:,H Select that heating circuit with⊕ / ⊝, to which the adjustmentshould apply.

H Confirm twice with .HAgain, press and hold down“ur+i simultaneously; a timeslot graphic shows the selectedtime phases.

For changing the time program, (seepage 26).

DHW time program

1.uw+i press and hold downsimultaneously for DHWtime program; the set timephases will then bedisplayed on a time slotgraphic.

Note:For changing the time program, (seepage 26).

5369299

v1.0

b

1-7

1-7

Page 34: Vitodens 200-User Manual

Scanning Options

34

Scanning Time Programs (continued)

Scanning fault display

If your heating system has developed a fault, it will be displayed and indicated bythe flashing red fault indicator.You can read off the fault code on the display by scanning; then notify your localheating contractor accordingly. This allows your heating contractor to betterprepare for the service call and may save additional travelling costs.

Boiler sensor

1 38U

Acknowledge? Yes

Fault display examples:

Control unit fault

Fault on a burner component

Press the following keys:

1.E in case of a fault on a burnercomponent.

2.i for troubleshooting.Example:In this case, notify your localheating contractor of fault (1)message “38”.

3. to “Acknowledge”.

4.⊕/⊝ for “Yes” or “No”.With “Acknowledge? Yes” youconfirm that you have notedthe fault.

5. to confirm.

Note:If the fault has not been rectified, thefault message will be displayed again at07:00 hrs. the following day.The red fault indicator flashes until thefault has been rectified.

5369299

v1.0

b

Fault

TuºF

Fault

E

Page 35: Vitodens 200-User Manual

Other Settings

35

Changing the Heating Pattern of the Boiler

Rooms are too cold

Cause Remedy

The heating system is switched OFF.ON indicator “8” (green) OFF.

Switch system ON / OFF switch “8” ON (see page 13).Switch ON the main breaker, if installed (outside the boiler room).Reset circuit breaker inside the power distribution panel.

Control unit or remote control incorrectlyadjusted.

Check settings and correct, if required:- Room temperature- Time- Time program

Only when operating with DHW heating:DHW priority (wp is displayed).

Wait until the DHW tank has been heated up (p disappears from thedisplay).

In connection with the Vitotronic 200-H orextension kit for heating circuits with mixingvalve: The ON / OFF switch on the mixing valvemotor is switched OFF.

Switch ON / OFF switch on the mixing valve motor ON, I=ON.

No fuel. With Natural Gas / LPG:Open the gas shut-off valve and check with your gas supplier, ifrequired. Press burner fault reset “E”.

”Fault” and “E” are displayed; the red faultindicator at the control unit flashes.

Press burner fault reset “E” - if that fails, notify your heatingcontractor.

Control unit fault: ”Fault” is displayed and the redfault indicator flashes.

Scan the type of fault and notify your local heatingcontractor.

Mixing valve motor faulty. Unhook motor lever A and manually set mixing valve lever B. Notifyyour local heating contractor.

Rooms are too hot

Cause Remedy

Control unit or remote control incorrectlyadjusted.

Check settings and correct, if required:- Room temperature- Time- Time program

Control unit or outside temperature sensor faulty:”Fault” is displayed and the red fault indicatorflashes.

Scan the type of fault and notify your local heatingcontractor.

5369299

v1.0

b

B

A

Page 36: Vitodens 200-User Manual

Other Settings

36

Changing the Heating Pattern of the Boiler (continued)

There is no hot water

Cause Remedy

The heating system is switched OFF.ON indicator “8” (green) OFF.

Switch system ON / OFF switch “8” ON.Switch ON the main breaker, if installed (outside the boiler room).Reset circuit breaker inside the power distribution panel.

Control unit or remote control incorrectlyadjusted.

Check settings and correct, if required:- DHW heating must be switched ON- DHW temperature- Time program- Time

No fuel. With Natural Gas / LPG:Open the gas shut-off valve and check with your gas supplier, ifrequired. Press burner fault reset “E”.

Control unit fault: ”Fault” is displayed and the redfault indicator flashes.

Scan the type of fault and notify your local heatingcontractor.

The DHW is too hot

Cause Remedy

Control unit incorrectly adjusted. Check and, if required, correct DHW temperature (see page 25).

”Select htg. circuit” flashes in the display

Cause Remedy

Control element activated without selecting aheating circuit first.

Select that heating circuit, to which the adjustment should apply

”Fault” flashes at the display

Cause Remedy

Heating system fault. Scan for the type of fault and notify your local heatingcontractor.

The time flashes at the display

Cause Remedy

Longer heating system off periods. Reset the time and date.

”Service” is displayed

Cause Remedy

The heating system requires a service. Ask your local heating contractor to service the boiler.

5369299

v1.0

b

Page 37: Vitodens 200-User Manual

Other Settings

37

Changing the Heating Pattern of the Boiler (continued)

“Remote control” is displayed

Cause Remedy

A remote control is connected to the heatingcircuit.

Make adjustments or carry out scans at the remote control (seeseparate operating instructions).

”Ext. control” is displayed

Cause Remedy

The heating program set at the control unit waschanged over by an external device(e.g. connection extension).

No action required. The heating program changeover was manuallyselected.

”Ext. program” is displayed

Cause Remedy

The heating program set at the control unit waschanged over by the Vitocom 100 communicatinginterface (not used).

No action required. The heating program changeover was manuallyselected.

”Ext. room t. setpt.” is displayed

Cause Remedy

A room set point temperature has been connectedvia the communication interface.

No action required. The connection was manually selected.

”Without function” is displayed

Cause Remedy

No function is allocated to the key you havepressed.

No action required. Select appropriate key.

5369299

v1.0

b

Page 38: Vitodens 200-User Manual

Service Instructions

38

Service Instructions for Your Heating System

Viessmann strongly recommends inspection/service of the boiler and the system bya licensed professional heating contractor once a year.

Before the heating season begins, the boiler with its burner(s) and direct vent systemshould be serviced by a qualified heating contractor. Service contracts may beestablished through gas suppliers or other licensed contractors in your area.

Regular inspection/service ensures trouble-free, energy-efficient and environmentallyfriendly heating activity of your heating system.

BoilerAll boilers must be cleaned on a regularbasis as debris build-up will result inincreased flue gas temperature, andthus in increased energy consumption.

Notes on operation:H Ensure boiler room and boilerare clean.

H Regularly check heating systempressure on the pressure gage:If the needle of pressure gage isbelow 12 psig, the system pressureis too low; in this case, pleasecontact your heating contractor.

Domestic hot water storage tankInspection and (if necessary) cleaning ofthe tank must take place within 2 yearsof initial start-up and as requiredthereafter.Cleaning of the inside surfaces of theDHW storage tank, including DHWconnections, may only be performed bya licensed professional heatingcontractor.

Vitocell 100:Viessmann recommends an annualinspection, and replacement if required,of the consumable anode by a licensedprofessional heating contractor.The inspection can be carried out duringregular operation of the heating system;shut-down is not required.The heating contractor measures theprotective current with an anode tester.

If the domestic cold water supply to thehot water storage tank has a watertreatment device (water softener)installed, ensure its proper workingcondition is checked regularly by yourheating contractor.

The same applies if a dirt trap or awater filter is installed in the domesticcold water supply. Any of these devicesinstalled in the domestic cold watersupply must be flushed out and servicedon a regular basis.

Drinking water filter (if installed)For hygienic reasonsH replace filter element every6 months on filters which cannot beflushed back, and perform a visualinspection every 2 months,

H flush back reversible flow filtersevery 2 months.

Safety valve (DHW tank)The safety valve function should bechecked every six months by venting,either by the system user or the localheating contractor. The valve seat maybecome contaminated.

Please follow manufacturer’sinstructions.

Please follow manufacturer’sinstructions.

5369299

v1.0

b

IMPORTANT

Page 39: Vitodens 200-User Manual

How to Save Energy

2

1 3

45

6

39

How to Save Energy

.... by heating correctlyApart from taking advantage of the benefits of a modern heating system, there is alot you can do yourself to achieve additional fuel savings. For instance:

H Don’t overheat:Aim at a room temperature of68ºF / 20ºC. Every degree less inroom temperature will reduce yourheating bills by up to 6%.

H Close window shutters 1 (if installed)at dusk.

H Operate thermostatic valves 2correctly.

H Don’t obstruct radiators 3 andthermostatic valves 2.

HMake use of individual adjustmentoptions of the control unit4;(e.g. ”normal room temperature”alternating with ”reduced roomtemperature”).

H Set the domestic hot watertemperature of the DHW tank 5 onthe control unit 4.

H Control your consumption of hotwater:A shower generally consumes lessenergy than a bath.

... with regular maintenanceRegular maintenance check-ups of your heating system6 by a licensed professionalheating contractor will ensure energy savings and environmentally friendly operation.

.... with effective insulationIf you wish to make use of additional energy-saving measures, check the thermalinsulation:

H of heating and domestic hot waterpipes.

H of external walls and the roof.H between heated and unheated rooms.H of the windows.

5369299

v1.0

b

Page 40: Vitodens 200-User Manual

Information

40

Lighting and Operating Instructions

5369299

v1.0

b

FOR YOUR SAFETY READ BEFORE OPERATINGW A R N I N G: If you do not follow these instructions exactly, a fire orexplosion may result causing property damage, personal injury or loss of life.

A. This appliance does not have a pilot. It is equippedwith an ignition device which automatically lightsthe burner. Do not try to light the burner by hand.

B. BEFORE OPERATING smell all around the appliancearea for gas. Be sure to smell next to the floorbecause some gas is heavier than air and will settleon the floor.WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electric switch; do not use anyphone in your building.

• Immediately call your gas supplier from aneighbor’s phone. Follow the gas supplier’sinstructions.

• If you cannot reach your gas supplier, call the firedepartment.

C. Use only your hand to push in or turn the gascontrol knob. Never use tools. If the knob will notpush in or turn by hand, don’t try to repair it, call aqualified service technician. Force or attemptedrepair may result in a fire or explosion.

D. Do not use this appliance if any part has been underwater. Immediately call a qualified servicetechnician to inspect the appliance and to replaceany part of the control system and any gas controlwhich has been under water.

1. STOP! Read the safety information above on thislabel.

2. Set thermostat or other operating control to lowestsetting.

3. Turn off all electric power to the appliance.

4. This appliance is equipped with an ignition devicewhich automatically lights the burner. Do not try tolight the burner by hand.

5. Close main gas shut-off valve.

6. Wait five (5) minutes to clear out any gas. Thensmell for gas, including near the floor. If you smellgas, STOP! Follow ”B” in the safety informationabove on this label. If you don’t smell gas, go to thenext step.

7. Open main gas shut-off valve.

8. Turn on all electric power to the appliance.

9. Set thermostat or other operating control todesired setting.

10. If the appliance will not operate, follow theinstructions ”To Turn Off Gas To Appliance” andcall your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1. Set thermostat or other operating control to lowestsetting.

2. Turn off all electric power to the appliance if serviceis to be performed.

3. Close main gas shut-off valve.

OPERATING INSTRUCTIONS

Closed

Open

Manual gas shutoff

Page 41: Vitodens 200-User Manual

41

5369299

v1.0

b

Page 42: Vitodens 200-User Manual

42

5369299

v1.0

b

Page 43: Vitodens 200-User Manual

43

5369299

v1.0

b

Page 44: Vitodens 200-User Manual

Viessmann Manufacturing Company Inc.750 McMurray RoadWaterloo, Ontario N2V 2G5 Canada1-800-387-7373 Fax (519) 885-0887www.viessmann.ca [email protected]

Viessmann Manufacturing Company (U.S.) Inc.45 Access RoadWarwick, Rhode Island 02886 USA1-800-288-0667 Fax (401) 732-0590www.viessmann-us.com [email protected]

44

Quick Reference

°C °F

-40 -40-35 -31-25 -13-20 -4-18 0-16 +3-14 +7-12 +10-10 +14-9 +16-8 +18-7 +19-6 +21-5 +23-4 +25-3 +27-2 +28-1 +300 +32

+1 +34+2 +36+3 +37+4 +39+5 +41+6 +43+7 +45+8 +46+9 +48

+10 +50+12 +54+14 +57+16 +61+18 +64+20 +68+25 +77+30 +86+35 +95+40 +104+50 +122+60 +140+70 +158+80 +176+90 +194+100 +212+110 +230