99

vrp 11 fiber optic - NPRU

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: vrp 11 fiber optic - NPRU
Page 2: vrp 11 fiber optic - NPRU

TelecommunicationTelecommunication

• Transport model is a simplistic mode of moving data from one source to one or more destinations through a medium.

• A medium is the means of movement of signals from node to node.

• A medium is any material that is used for propagation or transmission of signals.

Page 3: vrp 11 fiber optic - NPRU

TelecommunicationTelecommunication

Page 4: vrp 11 fiber optic - NPRU

Channel

Wire Line Wireless

TelecommunicationTelecommunication

• Copper

• Coax

• Fiber

• Satellite

• Mobile phone

•Bluetooth

Page 5: vrp 11 fiber optic - NPRU

FibreFibre Optic CommunicationOptic Communication

Page 6: vrp 11 fiber optic - NPRU

History Fiber OpticHistory Fiber Optic

• พ.ศ. 2413 นักวิทยาศาสตรชาวอังกฤษ จอนทนิดัล (John Tyndall) พบวาแสงสามารถสงผานไปตามลําน้ําได

• พ.ศ.2423 อเล็กซานเดอร เกรแฮมเบลล (Alexandre Graham Bell) ผูประดิษฐระบบโทรศัพทสงขอมูลดวยแสง

• พ.ศ. 2493 สงสญัญาณภาพในรูปของแสงกับอุปกรณที่เรียกวาเอ็นโดสโคป (Endoscope)

• พ.ศ. 2503 มีการทดลองใชเลเซอรเปนครัง้แรก

• พ.ศ. 2509 นักวิทยาศาสตรชาวอังกฤษ ชื่อ ฮอคแคม (G.A. Hockham) และเกา(C.C. Kao)ไดทําการศึกษาวิจัยวาตัวกลางทีท่ําดวยใยแกวนําแสงสามารถสงผานแสงได 1%ของแสงอินพุตดวยระยะทาง 1 km

• พ.ศ. 2513 บริษัทคอรนนิง่ของอเมริกา ไดประสบผลสาํเร็จในการผลิตเสนใยแกวจากเนื้อแกวบริสทุธิ์ ที่สามารถนํามาใชในการสื่อสารขอมูลเชิงพาณิชยไดเปนรายแรกของโลก

Page 7: vrp 11 fiber optic - NPRU

Using Fiber OpticUsing Fiber Optic• การสื่อสารระยะไกล หรือภายในเมือง

• ระบบสื่อสารระยะไกล ที่มีความจุขอมูลสูง• ระบบอิเล็กทรอนิกส สวิตชชิ่ง หรือชุมสายโทรศัพท ระบบสื่อสารเคเบิ้ลใตน้ํา• ระบบการสงกระจายเสียงวทิยุ และโทรทัศน

• ในงานทีม่ีสัญญาณรบกวนสูง• การสงขอมูลทางอุตุนิยมวิทยา • การสงขอมูลระหวางสถานีรถไฟ หรือควบคุมสญัญาณรถไฟ• การสงขอมูลเกี่ยวกับระบบไฟฟากําลัง

• การสื่อสารภายในสํานักงาน หรือตึกสูงๆ• การสงขอมูลบนเครื่องบิน• การสงขอมูลในเรือ

Page 8: vrp 11 fiber optic - NPRU

Good Think Fiber OpticGood Think Fiber Optic

• การสูญเสียในการสงต่ํา วางระยะหางของรีพีทเตอรไดไกลขึ้นหรือไมมีรีพีทเตอร

• ไมเปนอินดัคตีฟคือไมเกิดอันตรายอันเนื่องจากการกระโชกของแรงดัน

• แถบความถี่หรือแบนวิดกวางมีความจุในการสงขอมูลไดสูง

• ปราศจากการรบกวนทางคลื่นแมเหล็กไฟฟา (EMI) ไมมีครอสทอลค (CROSS TALK) จึงทําใหหมดปญหาในการชีลด

• ไมเปนคอนดัคตีฟเปนการแยกกันทางไฟฟาระหวางเครื่องรับกับเครื่องสงจึงตัดปญหาเรื่องกราวดลูป

• ขนากเล็ก และน้ําหนักเบาประหยดัเนื้อที่

• ยากตอการลักลอบขโมยขอมูลจากสายจึงเปนการรักษาความปลอดภัยที่ดี

• วัสดุใชผลิตหางาย และประหยัดกวาถาเทียบกันกับทองแดง

Page 9: vrp 11 fiber optic - NPRU

The Carrier The Carrier -- LightLight

RaysWavesParticles

AbsorptionEmission

Interference RefractionReflection

Bandgap

Conduction band

Valence band

n0

n1

n0

Page 10: vrp 11 fiber optic - NPRU

Electromagnetic SpectrumElectromagnetic Spectrum

Frequency

SonicUltrasonic

AM Broadcast

Shortwave Radio

FM Radio/TVRadar

Infrared Light

Visible LightUltraviolet

X-Rays

Wavelength 1 Mm 1 km 1 m 1 mm 1 pm1 nm

1 kHz 1 MHz 1 GHz 1 THz 1 ZHz1 YHz

c = f • λ • nc: Speed of light ( 2.9979 m/µs ) f: Frequencyλ: Wavelengthn: Refractive index

(vacuum: 1.0000; standard air: 1.0003; silica fiber: 1.44 to 1.48)

Page 11: vrp 11 fiber optic - NPRU

LW Transmission BandsLW Transmission Bands

Near InfraredFrequency

Wavelength1.6

229

1.0 0.8 µm0.6 0.41.8 1.4

UV

(vacuum) 1.2

THz193 461

0.2

353

Longhaul Telecom

Regional Telecom

Local Area Networks850 nm

1550 nm

1310 nmCD Players780 nm

HeNe Lasers633 nm

Page 12: vrp 11 fiber optic - NPRU

CoherenceCoherence

• Coherent lightPhotons have fixed phase relationship (laser light)

• Incoherent lightPhotons with random phase(sun, light bulb)

• Coherence length (CL)Average distance over which photons lose their phase relationship

1/e

1

CL

Page 13: vrp 11 fiber optic - NPRU

InterferenceInterference

• Incoherent light adds up optical power

• Coherent light adds electromagnetic fields

• Zero phase shift:constructive interference

• 180º phase shift:

destructive interference+ =

+ =

Page 14: vrp 11 fiber optic - NPRU

Optical PowerOptical Power

• Power (P):• Transmitter: typ. -6 to +17 dBm (0.25 to 50 mW)• Receiver: typ. -3 to -35 dBm (500 down to 0.3 µW) • Optical Amplifier: typ. +3 to +20 dBm (2 to 100 mW)

• Laser safety • International standard: IEC 825-1• United States (FDA): 21 CFR 1040.10 • Both standards consider class I safe under reasonable forseeable

conditions of operation (e.g., without using optical instruments, such as lenses or microscopes)

Page 15: vrp 11 fiber optic - NPRU

Laser Power Limits Of Class ILaser Power Limits Of Class I(for test equipment applications)(for test equipment applications)

IEC 825-1 (EN 60825-1)

Wavelength Fiber / NA Limit

850 nm MM / 0.15 0.44mW

1200 to MM / 0.15 8.9 mW1400 nm SM / 0.10 8.9 mW

1400 to SM / 0.10 10 mW4000 nm

21 CFR 1040.10

Wavelength Fiber / NA Limit

850 nm MM / 0.15 2.8 mW

1060 to MM / 0.15 4.9 mW

1400 nm SM / 0.10 1.9 mW

1400 to SM / 0.10 7.84

2500 nm

(1984) (11/1993)

Page 16: vrp 11 fiber optic - NPRU

ReflectionsReflections

• Reflections: root cause for many problemsReturn loss definition:

RL = 10 * log

Pr

Pi

P reflected

P incident

Page 17: vrp 11 fiber optic - NPRU

Numerical Aperture (NA)Numerical Aperture (NA)

Acceptance / Emission Cone

NA = sin θ = n2core - n2

cladding

θ

Page 18: vrp 11 fiber optic - NPRU

Attenuation In Silica FibersAttenuation In Silica Fibers

900 1100 1300 1500 1700

0.5

1.0

1.5

2.0

2.5

OH Absorption

Atte

nuat

ion

(dB

/km

)

Wavelength (nm)

“Optical Windows”

2 3

1

Main cause of attenuation: Rayleigh scattering in the fiber core

Page 19: vrp 11 fiber optic - NPRU

Material AspectsMaterial Aspects

• Silicon (Si)• Least expensive

• Germanium (Ge)• “Classic” detector

• Indium gallium arsenide (InGaAs)• Highest speed

Wavelength nm500 1000 1500

Silicon

Germanium

InGaAs

Quantum Efficiency = 1

0.1

0.5

1.0Responsivity (A/W)

Page 20: vrp 11 fiber optic - NPRU

Fiber FundamentalsFiber Fundamentals

Fiber types-9/125µm Single mode-50/125µm and 62.5/125µmmultimode

125µm

50 or 62.5µm

9µm

Cladding

CoreTrends-Lower attenuation and dispersion-Lower cost per ft.-More fibers per cable: From 8 to 288

Page 21: vrp 11 fiber optic - NPRU

SingleSingle--Mode Fiber (SMF)Mode Fiber (SMF)

• Step-Index type with very small core• Most common design: 9/125 µm or 10/125 µm, NA ~ 0.1• Bitrate x Distance product: up to 1000 Gb/s • km

(limited by CD and PMD - see next slides)

n

r

1.4651.460

Page 22: vrp 11 fiber optic - NPRU

StepStep--Index (SI) FiberIndex (SI) Fiber

RefractiveIndex (n)

Diameter (r)

Cladding

Primary coating(e.g., soft plastic)

Core

1.4801.460

SiO2 Glass

• Most common designs: 100/140 or 200/280 µm

• Plastic optical fiber (POF): 0.1 - 3 mm ∅, core 80 to 99%

140 µm

100 µm

Page 23: vrp 11 fiber optic - NPRU

Multimode StepMultimode Step--Index (MM)Index (MM)

Pulse broadening due to multi-path transmission.

Bitrate x Distance product is severely limited!

100/140 µm Silica Fiber: ~ 20 Mb/s • km0.8/1.0 mm Plastic Optical Fiber: ~ 5 Mb/s • km

Page 24: vrp 11 fiber optic - NPRU

MultimodeMultimode GradientGradient--Index (GI) FiberIndex (GI) Fiber

• Doping profile designed to minimize “race” conditions(“outer” modes travel faster due to lower refractive index!)

• Most common designs: 62.5/125 or 50/125 µm, NA ~ 0.2• Bitrate x Distance product: ~ 1 Gb/s • km

n

r

1.4751.460

Page 25: vrp 11 fiber optic - NPRU

Plastic Optic Plastic Optic Fiber(POFFiber(POF))

การสื่อสารเครือขายแบนดวิดทกวางนับวามีความสําคัญมากในการนํามาใชงานทางดานสื่อสาร ทั้งทางดานขอมูล ภาพ และเสียง เสนใยพลาสติกนําแสง (Plastic OpticalFiber , POF) ในปจจุบันนั้นสามารถสงผานขอมูลไดมากขึ้นถึง 300 Mbit/s ถึง 3 Gbit/sถึงแมจะไมเทียบเทากับความสามารถของใยแกวนําแสงก็ตาม แตนับวามีอัตราที่มากกวาการใชสายทองแดง ดวยเสนผานศูนยกลางขนาด 1 มิลลิเมตร ทําใหงายตอการติดตั้งและเดินสายมากกวาใยแกว เสนใยพลาสติกนั้นเหมาะสมกับการสงขอมูลในระยะทางใกล ๆ ประมาณ 100 เมตร หรือ นอยกวา อยางเชน ระบบ LAN และการสื่อสารสื่อประสม แมกระทั่งการสงขอมูลแบบอะซิงโครนัส (Asynchronous Transfer Mode , ATM)

Page 26: vrp 11 fiber optic - NPRU

Chromatic Dispersion (CD)Chromatic Dispersion (CD)

• Light sources are NOT monochromatic(linewidth of source, chirp effects, modulation sidebands)

• Different wavelengths travel at slightly different speeds(this effect is called “Chromatic Dispersion”)

• Chromatic dispersion causes pulse broadening(problem at high bit rates over long distances)

• Standard single-mode fiber:

• 1300 nm window has lowest CD• 1550 nm lowest loss

Page 27: vrp 11 fiber optic - NPRU

Chromatic Dispersion in Optical FiberChromatic Dispersion in Optical Fiber

Page 28: vrp 11 fiber optic - NPRU

Relation of bit rate to DispersionRelation of bit rate to Dispersion

Page 29: vrp 11 fiber optic - NPRU

DispersionDispersion--Shifted Fiber (DSF)Shifted Fiber (DSF)• Additional doping to shift zero dispersion to 1550 nm

• Now 1550 nm lowest loss AND lowest dispersion • Can cause nonlinear effects in DWDM systems (see later)

• Non-Zero Dispersion Shifted Fiber (NZDSF)• Low dispersion around 1550 nm and low nonlinear effects• Requires chromatic dispersion compensators on long distances

0

20

C. D

ispe

rsio

n ps

/(nm

•km

)

-10 1600 1700140013001200 1500

10

SMF NZDSFDSF

Page 30: vrp 11 fiber optic - NPRU

Dispersion Compensating Fiber (DCF)Dispersion Compensating Fiber (DCF)

Page 31: vrp 11 fiber optic - NPRU

Types of Dispersion in Optical FiberTypes of Dispersion in Optical Fiber

Page 32: vrp 11 fiber optic - NPRU

Basic Link DesignBasic Link Design

Transmitter Connector Cable

ReceiverCableSplice

Page 33: vrp 11 fiber optic - NPRU

Typical Long Distance SystemTypical Long Distance System

TerminalEquipment

AmplifierUnit

RegeneratorUnit

TerminalEquipment

AmplifierUnit

AmplifierUnit

Amplifier spans: 30 to 120 kmRegenerator spans: 50 to 600 kmTerminal spans: up to 600 km (without regenerators)

up to 9000 km (with regenerators)

Two pairs of single-mode fiber

Page 34: vrp 11 fiber optic - NPRU

LightLight--emitting Diode (LED)emitting Diode (LED)

• Datacom through air & multimode fiber• Very inexpensive (laptops, airplanes, lans)

• Key characteristics• Most common for 780, 850, 1300 nm• Total power up to a few µW• Spectral width 30 to 100 nm• Coherence length 0.01 to 0.1 mm • Little or not polarized• Large NA (→ poor coupling into fiber) P -3 dB

P peak

BW

Page 35: vrp 11 fiber optic - NPRU

FabryFabry--Perot (FP) LaserPerot (FP) Laser• Multiple longitudinal mode (MLM) spectrum• “Classic” semiconductor laser

• First fiberoptic links (850 or 1300 nm)• Today: short & medium range links

• Key characteristics• Most common for 850 or 1310 nm• Total power up to a few mw• Spectral width 3 to 20 nm• Mode spacing 0.7 to 2 nm• Highly polarized• Coherence length 1 to 100 mm• Small NA (→ good coupling into fiber)

P peak

I

PThreshold

Page 36: vrp 11 fiber optic - NPRU

Distributed Feedback (DFB) LaserDistributed Feedback (DFB) Laser• Single longitudinal mode (SLM) spectrum• High performance telecommunication laser

• Most expensive (difficult to manufacture)• Long-haul links & DWDM systems

• Key characteristics• Mostly around 1550 nm• Total power 3 to 50 mw• Spectral width 10 to 100 MHz (0.08 to 0.8 pm)• Sidemode suppression ratio (SMSR): > 50 dB• Coherence length 1 to 100 m• Small NA (→ good coupling into fiber)

P peak

SMSR

Page 37: vrp 11 fiber optic - NPRU

Photo DiodesPhoto Diodes• PIN (p-layer, intrinsic layer, n-layer)

• Highly linear, low dark current

• Avalanche photo diode (APD)• Gain up to x100 lifts detected optical signal

above electrical noise of receiver• Best for high speed and highly sensitive

receivers• Strong temperature dependence

• Main characteristics• Quantum efficiency (electrons/photon)• Dark current• Responsivity (current vs. Λ)

n+

Bias Voltage

AP

D G

ain

Page 38: vrp 11 fiber optic - NPRU

RegeneratorRegenerator• Receiver followed by a transmitter

• No add or drop of traffic• Designed for one bit rate & wavelength

• Signal regeneration• Reshaping & timing of data stream• Inserted every 30 to 80 km before optical amplifiers became

commercially available• Today: reshaping necessary after about 600 km (at 2.5 Gb/s), • often done by SONET/SDH add/drop multiplexers or digital cross-

connects

Page 39: vrp 11 fiber optic - NPRU

SplicesSplices• Fusion Splices

• Most common permanent fiber connection• Very high performance and reliability• Insertion loss 0.01 to 0.1 dB, no reflection• Automated splicing tool costs $10k to $50k

• Mechanical Splices• Permanent and non-permanent types• Insertion loss 0.1 to 0.5 dB• Index-matching liquid used to minimize loss & reflections• Epoxy or UV hardened elastomer based• Less expensive tools ($100 to $1,000) required

Protective sleeve

Splice

Page 40: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 41: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 42: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 43: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 44: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 45: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 46: vrp 11 fiber optic - NPRU

Fibre Splicing and ConnectingFibre Splicing and Connecting

Page 47: vrp 11 fiber optic - NPRU

Connector TechnologyConnector Technology

• Ultra-high precision

• Optical axis aligned to better than ±1 µm (single-mode)

• Physical contact of the glass end surfaces necessary to avoid strong reflections.

Sleeve

Ferrule

FiberKey

• Connector cleanliness is paramount

• dirt can add insertion loss, and damage connections.

Page 48: vrp 11 fiber optic - NPRU

Fiber Ribbon ConnectorsFiber Ribbon Connectors

Page 49: vrp 11 fiber optic - NPRU

Connector TypesConnector Types• Fiber end polishing: straight or angled• Common mechanical styles: ST, SC ,FC/PC, DIN

Page 50: vrp 11 fiber optic - NPRU

Issues Of Connecting FibersIssues Of Connecting Fibers

Offset Angular Misalignment

Separation

Core Eccentricity Core Ellipticity Reflections &Interference

Page 51: vrp 11 fiber optic - NPRU

Medium insertion loss:

Worst return loss:< 14 dB (Fresnel)

Common multimodefiber connector

Air Gap

typ. 0.5 dBLowest insertion loss:

< 0.25 dB

Good return loss:

Common single-modefiber connector

Physical Contact(PC)

> 40 dB

Highest insertion loss:

Best return loss:

Cable TV, highperformance systems

Angled PhysicalContact (APC)

0.4 to 0.9 dB

> 60 dB

Issues Of Connecting FibersIssues Of Connecting Fibers

Page 52: vrp 11 fiber optic - NPRU

Common Connector Types Used with OTDRs

Worst return loss:<14 dB (Fresnel)

Best return loss:Good return loss:>30-55dB dB >60 dB

Air Gap(straight)

Physical Contact(straight)

Angled Physical Contact(Slanted)

A physical contact, angled-type connector on theOTDR could reduce deadzones.

Common multimodefiber connector

Common single-modefiber connector

Cable TV, highperformance systems

8

Worst return loss:< 14 dB (Fresnel) Good return loss:

> 40 dBBest return loss:

> 60 dB

Page 53: vrp 11 fiber optic - NPRU

Connector InspectionConnector Inspection

Don’t stare into the laser beam

(with your remaining eye)Inspection Tool

Page 54: vrp 11 fiber optic - NPRU

Connector CareConnector Care

New Connector Damaged Connector

Page 55: vrp 11 fiber optic - NPRU

Connector CleaningConnector Cleaning

Pure Cotton Swabs

Isopropyl Alcohol

Filtered Air

Variety of cleaning methods in use today

Example:Clean connector tips with Isopropyl (96% medical alcohol) using adhesive free cotton swabs

Immediately dry it with dust-free, non residue compressed air

Page 56: vrp 11 fiber optic - NPRU

What is a fiber optic link

Used to connect a transmitter to a receiver from distances between 2ft to 200 miles

Main physical specifications are–Total Link loss and loss over distance–Individual reflection and total link return loss –Link length

FusionSplice

Bend ConnectorPair

Crack FiberEnd

MechanicalSplice

Typical Fiber Link

Tx Rx

Page 57: vrp 11 fiber optic - NPRU

What can an OTDR do?

a break point splice and connector lossespoint-to-point distances total cable lengthconnector quality (return loss)attenuation of the fiber

It is optical radar and can measure:

FusionSplice

Bend Connector Crack FiberEnd

MechanicalSplice

Loss

Distance

Installation and CommissioningMaintenance.Emergency RestorationFiber identification.

An OTDR is used for fiber:

Page 58: vrp 11 fiber optic - NPRU

What is an OTDR?

.

FusionSplice

Bend ConnectorPair

Crack FiberEnd

MechanicalSplice

Fiber Network

OTDR Measurement DisplayR

elat

ive

Pow

er (d

B)

Optical Time Domain Reflectometer

Laser

Coupler

PulseGenerator

Detector

Analyzing Circuitry + Display"Intelligence"

Page 59: vrp 11 fiber optic - NPRU

Fiber events and their trace representation

Backscatter

Mechanical Spliceor Connector

Air gap

CrackLoss

Reflection

(Non-Reflective)

Broken fiber-endCleaved end or open connector

(Reflective)

Reflection non reflective

Bend

Loss

Fusion Splice

Page 60: vrp 11 fiber optic - NPRU
Page 61: vrp 11 fiber optic - NPRU

Single CoreSingle Coreเปนใยแกวเดี่ยวชนิดหนึ่ ง

โดยใยแกวจะอยูตรงกลางและล อ ม ร อบด ว ย วั ส ดุ บั ฟ เ ฟ อ ร (buffer material) เพื่อปองกันอันตรายที่อาจเกิดขึ้นกับเสนใยแกว โดยวัสดุนี้มีความคงทนตอปฏิกิริยายาทางเคมีดีเยี่ยม

Page 62: vrp 11 fiber optic - NPRU

Multi CoreMulti CoreBundle cable ก็เปนรูปหนึ่ง

ของสาย เสนใยแกวหลายๆเสนรวมอยู สายประเภทนี้มีการสูญเสียคอนขางสูงจึงเหมาะใชงานไมยาวนัก อีกแบบหนึ่งเปนแบบเสนใยแตละอันแยกกันดวยฟลเตอร และมีการเคลือบวัสดุบัฟเฟอรกับเปลือกนอกแ ต ล ะ ตั ว แ ย ก กั น โ ด ย มี tabular wrapping ยึดติดเขาดวยกัน

Page 63: vrp 11 fiber optic - NPRU

มีการผลิตออกมาตามความมีการผลิตออกมาตามความตองการของผูใชตองการของผูใช โครงสรางของมันจึงมีโครงสรางของมันจึงมีส ว น ป ร ะ ก อ บ อื่ น ๆส ว น ป ร ะ ก อ บ อื่ น ๆ ร ว ม อ ยู ด ว ยร ว ม อ ยู ด ว ย นอกเหนือจากเสนใยแกวนอกเหนือจากเสนใยแกว และวัสดุและวัสดุเคลือบหอหุมเคลือบหอหุม

Special Optic FiberSpecial Optic Fiber

Page 64: vrp 11 fiber optic - NPRU

Fibre fabricationFibre fabrication

Page 65: vrp 11 fiber optic - NPRU

Outside Outside vapourvapour phase oxidation (OVPO)phase oxidation (OVPO)

Page 66: vrp 11 fiber optic - NPRU

Double crucible method fibre drawingDouble crucible method fibre drawing

Page 67: vrp 11 fiber optic - NPRU

Coding Fiber OpticCoding Fiber Optic

Page 68: vrp 11 fiber optic - NPRU

Coding Fiber OpticCoding Fiber Optic

Page 69: vrp 11 fiber optic - NPRU

Packaging Fiber OpticPackaging Fiber Optic

Page 70: vrp 11 fiber optic - NPRU

Packaging Fiber OpticPackaging Fiber Optic

Page 71: vrp 11 fiber optic - NPRU

Packaging Fiber OpticPackaging Fiber Optic

Page 72: vrp 11 fiber optic - NPRU

Packaging Fiber OpticPackaging Fiber Optic

Page 73: vrp 11 fiber optic - NPRU

สายเคเบิลใยแกวประเภทตางๆสายเคเบิลใยแกวประเภทตางๆการจัดแบงประเภทของสายเคเบิลใยแกว อาจมีหลักการในการ

จําแนกออกไดหลายลักษณะ ในที่นี้จะกลาวถึงการจําแนกสายเคเบิลใยแกวเพียงสองลักษณะ คือ การจําแนกตามลักษณะโครงสรางของสายเคเบิล และ การจําแนกตามประเภทของการใชงาน

Page 74: vrp 11 fiber optic - NPRU

ชนิดเสนเดี่ยวทอหลวม(single-fiber loose buffer)

Page 75: vrp 11 fiber optic - NPRU

ชนิดเสนรวมทอหลวมชนิดเสนรวมทอหลวม(multi(multi--fiber loose buffer)fiber loose buffer)

Page 76: vrp 11 fiber optic - NPRU

ชนิดทอแนนชนิดทอแนน(Tight buffer)(Tight buffer)

Page 77: vrp 11 fiber optic - NPRU

ชนิดแถบแบนชนิดแถบแบน(Ribbon type)(Ribbon type)

Page 78: vrp 11 fiber optic - NPRU

ชนิดแบงชนิดแบงสล็อตสล็อต(slot type)(slot type)

Page 79: vrp 11 fiber optic - NPRU
Page 80: vrp 11 fiber optic - NPRU

อุปกรณตางๆ ที่ใชทําหัวสัญญาณแบบ Fiber Optic

Page 81: vrp 11 fiber optic - NPRU

คีมเขาหวั Fiber Optic แบบ Out Door

Page 82: vrp 11 fiber optic - NPRU

อุปกรณที่ใชทําหัว Fiber Optic แบบ In Door

Page 83: vrp 11 fiber optic - NPRU

กลองตรวจสอบหัว Fiber Optic

Page 84: vrp 11 fiber optic - NPRU

ผสมสารที่ใชยดึติดสาย Fiber Optic กับหัวของสายสัญญาณ

Page 85: vrp 11 fiber optic - NPRU

ปลอกสายชั้นนอก

Page 86: vrp 11 fiber optic - NPRU

ปลอกสายชั้นทีส่องออก

Page 87: vrp 11 fiber optic - NPRU

ปลอกสายชั้นทีส่ามออก

Page 88: vrp 11 fiber optic - NPRU

ฉีดสารยึดติดเขาหัวสญัญาณ

Page 89: vrp 11 fiber optic - NPRU

นําสารยึดติดที่ผสมไวรวงหนาฉีดเขาไปในหัวสายสัญญาณนําสารยึดติดที่ผสมไวรวงหนาฉีดเขาไปในหัวสายสัญญาณ

Page 90: vrp 11 fiber optic - NPRU

รอยสายสัญญาณ

Page 91: vrp 11 fiber optic - NPRU

รอยสายสัญญาณและเสียบเขากับหัวทีไ่ดฉีดสายยึดไว

Page 92: vrp 11 fiber optic - NPRU

นําสายที่เสียบเขากับหวัสัญญาณไปอบ

Page 93: vrp 11 fiber optic - NPRU

นําสายที่อบแลวไปตัดสวนปลายที่เกินออก

Page 94: vrp 11 fiber optic - NPRU

ใชหัวตัดชนดิพิเศษตัดสวนปลายที่ยังเหลืออยูสวนโคนของหวัสัญญาณ

Page 95: vrp 11 fiber optic - NPRU

นําแผนขัดหัวชนิดพิเศษขัดสวนปลายของหัวสัญญาณ

Page 96: vrp 11 fiber optic - NPRU

นําหัวของสายสัญญาณเสียบเขากับตัวประคองแลวนําไปขดัแบบวนไปวนมาเหมือนเลข 8

Page 97: vrp 11 fiber optic - NPRU

นําหัวทีข่ัดแลวมาสองกับกลองเพื่อตรวจสอบรอยที่เกดิจากการขัด

Page 98: vrp 11 fiber optic - NPRU

นําสายที่ทําเสรจ็แลวไปติดตั้ง

Page 99: vrp 11 fiber optic - NPRU