10
WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 [email protected] BOOSTUAE.COM BLOG.BOOSTUAE.COM Duration: Five Days Location: TBD Date: TBD This course will bring people responsible for water treatment in their facilities up to speed regardless of their current situation, whether they are specifying a new system, or trying to keep an old system alive for as long as possible.

WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 [email protected] BOOSTUAE.COM BLOG.BOOSTUAE.COM

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

WATER TREATMENT FOR BOILERS, CHILLERS, AND

COOLING TOWERS

+971 2 449 6000 +971 50 412 3294 [email protected]

BOOSTUAE.COM BLOG.BOOSTUAE.COM

Duration:

Five Days

Location:

TBD

Date:

TBD

This course will bring people responsible for water treatment in their facilities up to speed regardless

of their current situation, whether they are specifying a new system, or trying to keep an old system

alive for as long as possible.

Page 2: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

07 Advanced

Reporting System

01

Interactive Engaging

Courses

02

Recognized

Certificates

03 Wide Range Of

Training Subjects

04 Global Training

Centers

05 In-House &

Customized Courses

06 Internationally

Certified Instructors

Why Us?

Few Words About Boost Our solutions are fully customized and designed based on the needs of our clients

Page 3: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

ABOUT THE COURSE

Duration:

Five Days

Location:

TBD

Date:

TBD

Many commercial, manufacturing and industrial processes involve the use of water as a primary medium.

These include the use of boilers and steam raising plant, cooling towers, cooling systems and other

closed circuit systems.

The water used in such systems, if left untreated can cause a number of problems leading to increased

risks to safety and health, reduced efficiency, and increased costs. These include the unwanted growth of

harmful bacteria and biofilm, the accumulation of scale (hardness salts), metallic corrosion, bio-fouling

and the build-up of suspended solids. The correct treatment of such system water is therefore vital if

these issues are to be effectively managed.

Plans and specifications for installing hvac systems in buildings are prepared with a great deal of time

and expense. Many times, however, some items are left to chance, with little or no thought given to

system maintenance once the project is completed. Water treatment of the hvac/r waterside often falls

into this category.

Precise planning on the part of the design professional can prevent serious start-up and operational

problems, and ensure system longevity, when a proper water treatment program is specified and

provided. Unfortunately, that forethought isn’t always done, and even if it is, that plan and information isn’t

always carried on down to the people actually maintaining the hvac/r systems, especially if they are years

down the road from design.

This course will bring people responsible for water treatment in their facilities up to speed regardless of

their current situation, whether they are specifying a new system, or trying to keep an old system alive for

as long as possible.

When attendees leave this course they will have a firm understanding of what it takes to get their water

treatment program into shape and keep it there.

Page 4: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

COURSE OBJECTIVES

Duration:

Five Days

Location:

TBD

Date:

TBD

UPON COMPLETION OF THIS COURSE, ATTENDEES WILL UNDERSTAND:

✓ Problems caused by poor water quality

✓ Water properties and chemistry as a basis for managing water quality

✓ Proper pre and post treatment of water for different systems and conditions

✓ How to reduce scale and corrosion inhibitors

✓ When to use automatic feeding compared to hand or slug feeding of chemicals

✓ When, where and how to inject chemicals into the system

✓ The importance of cleaning brand new systems, as well as systems already in use

✓ Advantages and disadvantages of new technologies

✓ The importance of vendor selection, service and accountability

✓ Setting up a routine service and maintenance program

TRAINING METHODOLOGY

Throughout this course, the attendees will have the opportunity to practice their skills through a variety of

hands-on exercises. These exercises focus on the skills introduced in each lesson. The following are our

tools for course conduction:

✓ Pre-Assessment Questionnaire for use before the Course

✓ Post-Assessment Questionnaire for use after the Course

✓ Lectures, Demonstrations, Group Exercises & Case Studies

✓ Visual aid (Video Simulation) to increase the efficiency of the information

✓ Evaluation Questionnaires (Course, Instructor, & Administration) filled by Attendees

✓ Evaluation Questionnaires for Attendees filled by Instructor

Page 5: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

TARGET PARTICIPANTS

Duration:

Five Days

Location:

TBD

Date:

TBD

This course is designed for anyone responsible for water treatment and quality in their plant or facility hvac

systems. Attendees come from a wide variety of industries, skill- levels, company sizes, and job titles, so if

you're not sure you'll fit in or will benefit from the class, don't worry - you will - as long as you are looking to

prevent water quality from becoming a problem at your facility!

People who will benefit from this program include…

All maintenance and supervisory personnel responsible for water treatment in:

✓ Manufacturing Plants

✓ Commercial Buildings

✓ Hospitals

✓ Waste Water Facilities

✓ Schools

✓ Government Buildings

✓ Research Facilities

✓ Shopping Centers

✓ Apartment Buildings Including:

✓ Building Maintenance Personnel

✓ Plant & Facility Maintenance Technicians

✓ Building Engineers

✓ Building Managers & Superintendents

✓ Plant & Facility Managers

✓ Environmental Health & Safety Personnel

✓ Apprentice and Experienced Boiler Technicians

✓ Stationary Engineers

✓ HVAC Design Engineers

✓ Energy Management Personnel

✓ Multi-craft & Cross Training Personnel

✓ Mechanical Engineers

✓ Any person needing a basic course in water treatment!

Page 6: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

WHAT YOU WILL GAIN

Duration:

Five Days

Location:

TBD

Date:

TBD

ON COMPLETION OF THIS COURSE YOU SHOULD BE ABLE TO UNDERSTAND:

✓ Boiler and Steam Waterside Problems

✓ Cooling Tower Problems

✓ Fundamentals of Water

✓ Properties of Water

✓ Water Chemistry

✓ Pre-treatment Methods

✓ Post-Treatment Methods

✓ Freeze Protection for Closed-Loop Systems

✓ Effective Water Treatment Practices for Industrial and Process Applications (including the treatment of

boilers, cooling towers, cooling systems and closed circuits.)

✓ Water Treatment Equipment

✓ Controlling Water Treatment Program Costs

Page 7: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

Course Outline

Duration:

Five Days

Location:

TBD

Date:

TBD

BOILER AND STEAM WATERSIDE PROBLEMS

✓ Scale

✓ Corrosion and Pitting

COOLING TOWER PROBLEMS

✓ Scale

✓ Corrosion

✓ Biological Fouling

FUNDAMENTALS OF WATER

✓ Origin

✓ Uses of water

PROPERTIES OF WATER

✓ Dissolved Gases and Minerals

✓ Dissolved and Suspended Solids

✓ Stability Index

WATER CHEMISTRY

✓ pH

✓ Alkalinity

✓ Hardness

✓ Chlorides

✓ Conductivity

✓ Cycles of Concentration

Page 8: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

Course Outline

Duration:

Five Days

Location:

TBD

Date:

TBD

PRE-TREATMENT METHODS

✓ Sodium-zeoldite water

✓ Dealkalization

✓ Deaeration

✓ Filtration

POST-TREATMENT METHODS

✓ Chemicals for boiler water

✓ Chemicals for cool water

FREEZE PROTECTION FOR CLOSED-LOOP SYSTEMS

✓ Ethylene Glycol

✓ Propylene Glycol

Effective water treatment practices for industrial and process applications (including the

treatment of boilers, cooling towers, cooling systems and closed circuits.)

✓ Bromgard cooling tower treatment

✓ cooling tower pack cleaning & disinfection – cip

✓ chlorine dioxide power

✓ boiler water sludge conditioners

✓ boiler water oxygen scavengers – sulphite, tannin, deha, carbohydrazide

✓ dhmo – us survey calls for outright ban

✓ magnetic water treatment v chemicals

✓ ultrasound cleaning of ceramic filters to aid water treatment

✓ nitrate in drinking water

✓ eco-friendly biocide – hydrogen peroxide silver

Page 9: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

Course Outline

Duration:

Five Days

Location:

TBD

Date:

TBD

✓ biofilm disinfection – hydrogen peroxide silver biocides

✓ private water supplies – wells, springs, boreholes

✓ disinfection by-products in drinking water

WATER TREATMENT EQUIPMENT

✓ Selection

✓ Installation

✓ Maintenance

CONTROLLING WATER TREATMENT PROGRAM COSTS

✓ New Technologies for Old Systems

✓ Vendor Selection and Accountability

OPEN DISCUSSION

Page 10: WATER TREATMENT FOR BOILERS, CHILLERS, …...WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS +971 2 449 6000 +971 50 412 3294 info@boostuae.com BOOSTUAE.COM BLOG.BOOSTUAE.COM

T H A N K Y O U

For any clarification or information. Please do not hesitate to contact us

Follow us on social media and get

offers and discounts …

Phone: + 971 2 449 6000 / +971 50 412 3294 Email: [email protected]

Course Name WATER TREATMENT FOR BOILERS, CHILLERS, AND COOLING TOWERS