Save up to 20% of your ELECTRICITY BILL WattStopper occupancy sensors

Watts Topper

Embed Size (px)

Citation preview

Page 1: Watts Topper

Save up to 20%of your ELECTRICITY BILL

WattStopperoccupancysensors

Page 2: Watts Topper

Low profile design

360o

coverage

SmartSetTM

technology

Walk- through mode

The NEW generation ofoccupancy sensors:Legrand’s new generation ofoccupancy sensors are packed with featuresand options that streamline sensor installationand strengthen performance - yet fit in a small,clean package.

Attractive new enclosures offer a flat,extremely low profile appearance thatleaves the ceiling clean anduncluttered.

With a full 360o coverage, thesesensors are able to control a widerange of applications, eitherindividually, or for large areas, inzones that overlap.

Watt Stopper SmartSet technology means noadjustments are needed at installation.SmartSet monitors the space to identify usagepatterns. With this information, it automaticallyadjusts the time delay and sensitivity settingsfor both optimal performance and maximumenergy efficiency.

The lights don’t need to stay on for the entirelength of the time delay if someone is justdropping off mail or other items. With oursmart Walk Through Mode, lights turn off 3minutes after an area is initially occupied ifno movement is detected within 30 seconds.

Page 3: Watts Topper

Quick terminal wiring

Low & line voltages

Diffusers

One touch light level

Terminal wiring and depluggable terminalwiring are featured throughout our newgeneration of occupancy sensors. Quick andeasy installations are now the new standard.

Low voltage sensors are well suited in mostapplications. The simplicity of low voltage wiringallows for optimal placement. However, someapplications, because of installer preference, arebetter suited to line voltage ceiling mount sensors.Our new generation of sensors are available in bothline and low voltage models to matchevery application and installation style.

Both the ultrasonic and dual technologysensors benefit from the new UltrasonicDiffusers. The diffusers are able to evenlydistribute the ultrasound in order to achievea more comprehensive coverage of thecontrolled area.

Many occupancy sensors contain a built-inlight level sensor. Our new generationsensors incorporate this feature PLUS aunique one-touch set up.

1

Page 4: Watts Topper

PIR technology senses occupancy by detecting the

difference between heat emitted from the human body in

motion and the background space.

Relying on a clear line-of-sight view, passive infrared

sensors make 100% coverage cut off possible. These

sensors use a unique Fresnel lens which divides the

coverage area into zones, enhancing detection of small

movement.

Watt Stopper PIR sensorsare enhanced with advancedtechnologies to ensure highersensitivity and minor motionwithout the potential for falseactivations. These includeDetection Signature Analysisand Pulse Count Processing.

WPIR

CX series

CI-200 series

CI-300 series

CB-100

Passive infraredtechnology

Passive infrared technology (PIR)

Occupancy sensor technologies

2

FOR MORE INFORMATIONvisit www.wattstopper.com

Page 5: Watts Topper

These sensors use our Advanced Signal Processing Circuitry toautomatically adjust the signal detection threshold incompensation for changing levels of activity and airFlow. Thishelps eliminate false ON activations common in other Ultrasonicsensors.

W seriesWT seriesUT-300 series

Ultrasonic technology

Using the Doppler principle, ultrasonic sensors work

by bouncing ultrasonic sound waves off objects in an

area and measuring the time it takes for the waves to

return. Movement by a person in the area causes the

sound waves to return at a changed frequency,

resulting in a Doppler shift and occupancy detection.

While PIR and Ultrasonic sensors provideoptimal control for a variety of spaces,some applications pose difficulty for singletechnology sensors.

We created and patented Dual Technology - acombination that takes advantage of the bestfeatures of both PIR and Ultrasonic technologies.Using the Dual Sensing Verification Principle, bothtechnologies must detect occupancy to turnlighting on, while continued detecting by only onetecnnology will hold lighting on.

Dual Technology sensorsensure the greatest sensitivityand coverage for toughapplications, without the threatof false triggers. This leads tothe greatest energy savings.

DT-200 seriesDT-300 series

Ultrasonic technology

Dual technology

Dual technology

3

Page 6: Watts Topper

Applying occupancy sensors

In offices, add a passive infrared sensor. Take advantage of thebuilt-in light level feature tokeep lights off when amplesunlight is present.

Control lighting in restrooms withultrasonic sensors and eliminatehours of unneeded on-time.Ceiling-mounted ultrasonics cansense motion around restroomstalls for reliable coverage.

In open or partitioned offices,use ultrasonic or dualtechnology sensors. Placed onthe ceiling, these sensorscover the area in zones thatoverlap.

• Warehouses• High ceiling mount locations• Library bookstack or other aisles• Common building areas• Lobbies• Computer rooms

PIRBest Applications

4

• Restrooms• Open office spaces• Offices• Enclosed hallways• Stairways

UltrasonicBest Applications

Page 7: Watts Topper

Common building spaces, such ascopy rooms, are ideal foroccupancy based control. With apassive infrared sensor placed inthe corner of the ceiling, userscan save hours of wasted lightingeach day.

In large conferencerooms, occupants may be therefor long periods of time.Dual technology sensors willbe able to detect the small motionand keep lights on as long as thespace is occupied.

Use occupancy sensorstogether with other controlmethods such as lightingcontrol panels or daylightingcontrols. Integrating controloptions can help you meetenergy codes and sustainabilityguidelines as well as maximizeenergy savings.

In warehouses, a passiveinfrared sensor mounted toa ceiling or fixture willcontrol the lightingbetween shelves - so thatlighting in unoccupied areaswill turn off or turn to a lowerlevel. Users can achieve thiscontrol with fluorescent as wellas HID lighting.

5

• Classrooms• Large conference rooms• Large offices• Lunch rooms

Dual TechnologyBest Applications

Page 8: Watts Topper

PIR occupancy sensor turns lights on and offbased on occupancy

User-adjustable sensitivity

User-adjustable time delay of 30 sec to 30 min

ASIC technology reduces components andprovides greater reliability

LED indicator

30 segment multi-element Fresnel lens

• Adjustable time delay of 30 sec to 30 min• Units per power pack: up to 8

• 63.5mm x 63.5mm x 29.0mm• UL and CUL listed, 5 year warranty

• Small offices • Computer rooms• Copy rooms • Racquetball courts• Break rooms • Library book stacks

ApplicationsSpecifications

WPIR Passive Infrared Sensor

CATALOG # VOLTAGE CURRENT COVERAGE

WPIR 24 VDC 14mA up to 28m2

All units use Watt Stopper power packs (p.17).

Order Information

6

Product Controls Wiring DIagram Coverage Patternfor ceiling mount

CeilingHeight Zone 5 Zone 4 Zone 3 Zone 2 Zone 1

Page 9: Watts Topper

CX Passive Infrared Sensor

Standard and long range coverage patterns

User-adjustable time delay and sensitivity

ASIC technology reduces components andprovides greater reliability

Swivel mounting bracket for convenient cornermounting to wall or ceiling

Built-in light level sensor (CX-100)

Isolated relay for use with HVAC or othercontrol systems (CX-100)

ApplicationsSpecifications

• Time delay of 15 sec to 30 min• Built-in light level sensor 32 to 2,152 lux (CX-100)• Units per power pack: CX-100 up to 6 ; CX-105 up to 14

• 83.8mm x 83.8mm x 53.3mm• UL and CUL listed, 5 year warranty

• Large offices • Open office spaces• Warehouses • Classrooms• Computer rooms • High bays

Order Information

7

0

0

SIDE0

TOP

15m

16m

3m

2m 4.5m 7.5m 16m

5m3m

3m

5m

3m5m 16m 25m 27.4m

Standard CX-100, CX-105 Long Range Lens: CX-100-1, CX-105-1

Coverages shown are maximum. Under ideal conditions, coverage for half-step walking motion(standard lens) can reach up to 186m2 for desktop activity up to 93m2

Coverage Patterns

All units use Watt Stopper power packs (p.17).

3m

CATALOG # VOLTAGE CURRENT COVERAGE FEATURES

CX-100 24 VDC 19 mA up to 186 m2 light level, isolated relay

CX-100-1 24 VDC 19 mA up to 27.4 m linear light level, isolated relay

CX-105 24 VDC 8 mA up to 186 m2

CX-105-1 24 VDC 8 mA up to 27.4 m linear

Wiring & Controls

Page 10: Watts Topper

360o coverage

User adjustable time delay and sensitivity

ASIC enhances reliability and helpseliminate false triggers

Isolated relay for use with HVAC or othercontrol systems (CI-200)

Built-in light level sensor (CI-200)

• Time delay 15 sec to 30 min• Built-in light level sensor 43 to 2,045 lux (CI-200)• SPDT isolated relay (CI-200)• Units per power pack: CI-200 up to 5; CI-205 up to 10

• 83.8mm diameter x 55.9mm total depth• UL and CUL listed, 5 year warranty

• Open or partitioned office spaces• Conference rooms• Computer rooms• Classrooms

ApplicationsSpecifications

CI - 200 Passive Infrared Sensor

Order Information

All units use Watt Stopper power packs (p.17).

8

13.4 m

7.3 m

Coverage shown represents half-step, walking motion.Typical coverage at the desktop is 46.5m2 withthe Extended Range lens and 111.5m2 with theHigh Density lens.

7m 4m 2m 1m 2m 4m 7m0

2.5m

1m

3,5m 2m 1m 2m0 1m 3,5m

2.5m

Coverage PatternsWiring & ControlsExtended Range Lens : CI-200, CI-205

High Density Lens: CI-200-1, CI-205-1

CATALOG # VOLTAGE CURRENT COVERAGE FEATURES

CI-200 24 VDC 20 mA up to 111.5 m2 light level, isolated relay

CI-200-1 24 VDC 20 mA up to 46.5 m2 light level, isolated relay

CI-205 24 VDC 11 mA up to 111.5 m2

CI-205-1 24 VDC 11 mA up to 46.5 m2

Page 11: Watts Topper

CI - 300 Passive Infrared Sensor

Architecturally appealing low profileappearance

SmartSet automatically selects optimaltime delay and sensitivity

Depluggable terminal wiring for quick andeasy installation

Accepts low voltage switch input for manual-onoperation (CI-300, CI-305)

Line and low voltage models available

Walk-through mode increasessavings potential

• Open offices• Conference rooms• Classrooms• Offices• Storage rooms• Computer rooms

Applications

• Units per power pack: CI-300 up to 5; CI-305 up to12• 144.3mm diameter x 25.9mm• UL and CUL listed, 5 year warranty

• Isolated relay with N/O and N/C outputs rated for 1 Amp at 30 VDC/VAC (CI-300)• Mounting options: ceiling tile; 4 square junction box with double gang mudring (CI-300, CI-305)• Mounting options: 4 square junction box with double gang mudring; octagonal junction box (CI-355)

• CI-300, CI-305: 24 VDC/VAC• CI-355: 120/230/277/347 VAC, 50/60 Hz• Time delays: SmartSet (automatic), fixed (5, 10, 15, 20, or 30 minutes), walk-through, test-mode• Sensitivity adjustment: SmartSet (automatic) or reduced sensitivity• Built-in light level sensor; 107 to 3,229 lux (CI-300,CI-355)

Specifications

CATALOG # VOLTAGE CURRENT COVERAGE FEATURES

CI-300 24 VDC 20 mA 111.5 m2 light level, isolated relay

CI-300-1 24 VDC 20 mA 46.5 m2 light level, isolated relay

CI-305 24 VDC 9 mA 111.5 m2

CI-305-1 24 VDC 9 mA 46.5 m2

CI-355 230/277 VAC, 50/60 Hz 0-1200 W Ballast 111.5 m2 light level

CI-355-1 230/277 VAC, 50/60 Hz 0-1200 W Ballast 46.5 m2 light level

Order Information

Low voltage models use Watt Stopper power packs (p.17).

9

7m 4m 2m 1m 2m 4m 7m0

2.5m

1m

2m 1m 2m0

2.5m

1m 3.5m

High Density/Reduced Range LensCI-300-1, CI-305-1, CI-355-1

Extended Range Lens (Standard)CI-300, CI-305, CI-355

13.4m

7.3m

Coverage PatternsWiring Diagrams

3.5m

Page 12: Watts Topper

CI Sensor for HVAC

Ceiling mount 360o sensor

Interface directly with EMS or HVAC systemthrough internal isolated relay

User adjustable time delay and sensitivity viaDIP switch

Four-level Fresnel lens offers superior desktopdetection

Advanced PIR technology

ASIC technology reduces components andenhances reliablility

• Time delay 30 seconds to 30 minutes• Isolated relay rated for 1 Amp at 24 VAC/VDC

Specifications

• 83.8mm diam x 55.9mm depth• UL and CUL listed, 5 year warranty

• Open or partitioned office spaces• Conference rooms

Applications

• Computer rooms• Classrooms

CB Low Temp Sensor

• Time delay 15 sec to 10 min• Temperature range -40oC to + 35oC• Units per power pack: up to 5

Specifications

• 100.1mm x 95.0mm x 60.0mm• UL and CUL listed, 5 year warranty

• Cold storage and freezers

Applications

Standard and long range coverage patterns

Convenient DIP switch adjustments for timedelay and sensitivity

Isolated relay contact for use with HVAC orother control systems

CI-12/CI-24 Order Information

CATALOG # VOLTAGE LOAD REQUIREMENTS COVERAGE

CI-12 12 VDC 28 mA See coverage

CI-24 24 VAC, VDC 37 mA

Extended Range lens is standard; Add -1 to Cat# for High Density/Reduced coverage lens.

CB-100 Order Information

Units are beige. Dense Wide Angle lens is standard; Add-1 to Cat# for Long Range.

CATALOG # VOLTAGE CURRENT COVERAGE

CB-100 24 VDC 20 mA See coverage patterns CX-100

10

PIR occupancy sensor for areas of extreme low temperature

Waterproof enclosure prevents moisture anddust from affecting detection

Page 13: Watts Topper

• Ultrasonic technology with 25KHz frequency• Temperature and humidity resistant receivers• Logic key/ON bypass• LED indicator

Specifications

• Adjustable sensitivity• Units per power pack: up to 7• 114.3mm x114.3mm x 31.8mm• UL and CUL listed, 5 year warranty

• Open and partitioned spaces• Restrooms

Applications

• Storage areas• Conference rooms• Hallways

Advanced, omni-directional,Doppler technology

Adjustable time delay from 15 secondsto 15 minutes

Up to 186m2 and hallwaycoverages available

Ideal for open office areas, conference roomsand restrooms

Advanced Signal Processing Circuitryautomaticallly adjusts detection threshold

CATALOG # VOLTAGE CURRENT COVERAGE

W-500A 24 VDC 16 mA 360o, 46.5 m2

W-1000A 24 VDC 16 mA 360o, 93 m2

W-2000A 24 VDC 16 mA 360o, 186 m2

W-2000H 24 VDC 16 mA 360o, 27.4 m linear

Order Information

All units use Watt Stopper power packs (p.17).

W Ultrasonic Occupancy Sensor

11

6m

4m

3m

1.5m

1.5m

3m

4m

6m

4.5m 6m 7.5m 13.5m

7.5m

9m

13.5m 7.5m 6m 1.5m

Coverage shownrepresents half-step,walking motion.**W-2000H coverage isnot drawn to scale

Coverage PatternsWiring Diagram

Page 14: Watts Topper

Ultrasonic technology with 32 KHz frequency

Utilizes advanced, omni-directional,Doppler technology

Advanced Signal Processing automaticallyadjusts detection threshold

User-adjustable DIP switch time delay andsensitivity settings

50 to 200 m2 and hallwaycoverage available

Isolated relay allows sensor to interface withbuilding control systems

WT Ultrasonic Occupancy Sensor

• Ultrasonic technology with 32 KHz frequency• Time delay 15 sec to 30 min• Isolated relay with N/O and N/C outputs; rated for 1 amp @ 30 VDC/VAC• 121.9mm diam x 38.1mm depth

Specifications

• Units per power pack: WT-605 up to 4; WT-600 up to 3; WT-1105, WT-2205, WT-2255 up to 3; WT-1100, WT-2200, WT-2250 up to 2• UL and CUL listed, 5 year warranty

• Open and partitioned spaces

• Restrooms

• Storage areas

• Conference rooms

• Hallways

Applications

CATALOG # VOLTAGE CURRENT COVERAGE FEATURE

WT-605 24 VDC 27 mA 360o one-sided, 56 m2

WT-600 24 VDC 37 mA 360o one-sided, 56 m2 isolated relay

WT-1105 24 VDC 30 mA 360o two-sided, 102 m2

WT-1100 24 VDC 40 mA 360o two-sided, 102 m2 isolated relay

WT-2205 24 VDC 30 mA 360o two-sided, 204 m2

WT-2200 24 VDC 40 mA 360o two-sided, 204 m2 isolated relay

WT-2255 24 VDC 30 mA 360o two-sided, 27.4 m linear

WT-2250 24 VDC 40 mA 360o two-sided, 27.4 m linear isolated relay

Wiring & Controls Coverage Patterns

Order Information

All units use Watt Stopper power packs (p.17).

12

Coverage shownrepresents half-step,walking motion

WT-2205

WT-605

WT-2255

WT-1105

13.7m 8m 6.7m 0 6.7m 8m 13.7m

6.4m

4.3m

1.5m

1.5m

4.3m

6.4m

0

Page 15: Watts Topper

Accepts low voltage switch input for manual-onoperation (UT-300, UT-305)

Ultrasonic diffusers give morecomprehensive coverage

Walk-through mode increasessavings potential

Architecturally appealing lowprofile appearance

SmartSet automatically selects optimal timedelay and sensitivity

Depluggable terminal wiring for quick andeasy installation

CATALOG # VOLTAGE CURRENT/LOAD REQ COVERAGE FEATURES

UT-300-X 24 VDC 43 mA see diagram light level, isolated relay

UT-305-X 24 VDC 37 mA

UT-355-X 120 VAC, 50/60 Hz 0-800 W light level 230/277 VAC, 50/60 Hz Ballast/Tungsten 347 VAC, 50/60 Hz 0-1200 W Ballast 0-1500 W Ballast

Order Information

X = 1 for 46.5 m2 of coverage; -2 for 93m2; -3 for 186 m2

Low voltage models use Watt Stopper power packs (p.17).

UT Ultrasonic Occupancy Sensor

• UT-300, UT-305: 24 VDC/VAC• UT-355: 120/230/277/347 VAC, 50/60 Hz• Time delays: SmartSet (automatic), fixed (5, 10, 15, 20, or 30 minutes), walk-through, test-mode• Sensitivity adjustment: SmartSet (automatic) or reduced sensitivity• Ultrasonic frequency of 40 kHz

Specifications

• Restrooms• Large Offices• Open Offices

Applications

• Isolated relay with N/O and N/C outputs rated for 1 Amp at 30 VDC/VAC (UT-300)• Built-in light level sensor, 107 to 3,229 lux (UT-300, UT-355)• Mounting options: ceiling tile; 4 square junction box with double gang mudring (UT-300, UT-305)• Mounting options: 4 square jungction box with double gang

mudring 4 inch octagonal junction box (UT-355)• Units per power pack : UT-300 up to 2; UT-305 up to 3• 144.3mm diam x 25.9mm• UL and CUL listed, 5 year warranty

UT-300 Wiring UT-355 Wiring Coverage Patterns

13

7m

5m

3m

0

3m

5m

7m

7m 5m 3m 0 3m 5m 7m

Coverages represent half-step walkingmotion. Actual coverages can vary for eachapplication based on room shape, use andobstacles.

UT-300-3

UT-300-2

UT-300-1

Page 16: Watts Topper

Combines passive infrared andultrasonic technologies

Trouble-free lighting control in applicationsdifficult for single technology sensors

Built-in light level sensor

SmartSet automatically selects optimal settingsfor each space

Accepts low voltage switch input formanual-on operation

Walk-through mode increases savingspotential

DT-200 Dual Technology Sensor

• 24 VDC/VAC• Ultrasonic frequency of 40 kHz• Time delays: SmartSet (automatic), fixed (5, 10, 15, 20, or 30 minutes), walk-through, test-mode• Sensitivity adjustment: SmartSet (automatic) or reduced sensitivity

Specifications

• SPDT isolated relay (DT-200)• Isolated relay with N/O and N/C outputs rated for 1 Amp at 24 VDC/VAC (DT-200)• Built-in light level sensor; 21 to 2,152 lux (DT-200)• Units per power pack: DT-200 up to 3; DT-205 up to 4

• Classrooms• Conference and training rooms• Large offices

Applications

CATALOG # VOLTAGE CURRENT COVERAGE FEATURES

DT-200 24 VDC 43 mA 186 m2 light level, isolated relay

DT-205 24 VDC 35 mA 186 m2

Wiring & Controls Coverage Patterns

Order Information

All units use Watt Stopper power packs (p.17).

• 111.8mm x 86.4mm x 50.8 mm• UL and CUL listed, 5 year warranty

14

3m

2m 4.5m 7.5m 16.5m

16.5m

11.5m

Coverages shown aremaximum. Under idealconditions, coverage forhalf-step walkingmotion (standard lens)can reach up to 186m2

for desktop activity upto 93 m2

Page 17: Watts Topper

Architecturally appealing low profileappearance

SmartSetTM automatically selects optimalsettings for each space

Ultrasonic diffusers give morecomprehensive coverage

CATALOG # VOLTAGE CURRENT/LOAD REQ COVERAGE FEATURES

DT-300 24 VDC 43 mA 93m2 light level, isolated relay

DT-305 24 VDC 35 mA 93m2

DT-355 120VAC, 50/60 Hz 0-800 W Ballast/Tungsten 93m2 light level

230/277 VAC,50/60Hz 0-1200 W Ballast

347 VAC, 50/60 Hz 0-1500 W Ballast

15

DT-300 Dual Technology Sensor

Accepts low voltage switch input for manual-onoperation (DT-300, DT-305)

Depluggable terminal wiring for quick and easyinstallation

Walk-through mode increases savings potential

Line and low voltage models available

• Classrooms• Open office spaces• Computer rooms

Applications

• DT-300, DT-305: 24 VDC/VAC• DT-355: 120/230/277/347/VAC, 50/60Hz• Time delays: SmartSet (automatic), fixed (5,10, 15, 20, or 30 minutes), walk-through, test-mode• Sensitivity adjustment: SmartSet (automatic) or reduced sensitivity• Ultrasonic frequency of 40 kHz

Specifications

• Isolated relay with N/O and N/C outputs rated for 1 Amp at 30 VDC.VAC (DT-300)• Built-in light level sensor; 107 to 3,229 lux (DT-300, DT-355)• Mounting options: ceiling tike;4 square junction box with double gang mudring (DT-300, DT-305)• Mounting options; 4 square junction box with double gang

mudring; 4 inch octagonal junction box (DT-355)• Units per power pack: DT-300 up to 2 , DT-305 up to 3• 144.3mm diam x 25.9mm• UL and CUL listed, 5 year warranty

Wiring Diagrams Coverage Patterns

Order Information

Low voltage models use Watt Stopper power packs (p.17).

This wiring diagram includes bi-level control andmanual-on option with momentary switch.

DT-300 Wiring DT-355 WiringCoverage shown is maximum and representshalf-step walking motion. Under ideal conditions,coverage for half-step walking motion can reachup to 93m2

Page 18: Watts Topper

Determines energy savings potential fromoccupancy sensor use

Adjustable light pipe observes lighting level

Logs when a space is occupied/ vacant andwhen lighting is on/off

IT-ProSoft Software provides single-step dataretrieval, storage, analysis, printing

Logs when a space is occupied/ vacant andwhen lighting is on/off

Small and lightweight for ease of useand portability

IT-200 InteliTimer Logger

• PIR technology• Lithium battery; 10 year average life• Test button to activate occupancy and light level LEDs for 90 seconds• Adjustable sensitivity

IT-200 Specifications

• Recessed reset switch• Stores up to 4096 entries• Stores site name to identify area being monitored• Connects to PC for data retrieval

• Reports show graphs of occupancy/lighting, potential money savings, statistical information• Operable in 6 languages• Windows compatible• Downloadable at www.wattstopper.com

CATALOG # DESCRIPTION

IT-200 Occupancy and light logger, PC connector cable included

IT-200 Controls Sample Logger Reports

Order Information

• List entries include number, date, time of entry, and lighting/occupancy status• Users set energy cost per kWh, size of controlled load, and site name• HVAC adder calculates savings from reduction of cooling

IT-ProSoft Software Specifications

16

Page 19: Watts Topper

Fully self-continued transformer and relay

Many models of power pack products forwide range of applications

Plenum rated

17

Power Pack

• Secondary voltage of 24VDC• Secondary output of 150 mA, 114 mA with relay connected• Low voltage leads rated for 300 volts• UL rated 94V-0 plastic enclosure, units are white• ABS UL 2043 plenum rated plastic and wiring with a 12.5 mm snap-in nipple• 41mm x 70mm x 41mm • UL and CUL listed, 5 year warranty

B Power Pack Specifications

CATALOG # INPUT VOLTAGE BALLAST(A) INCAN(A) MOTOR(HP) OUTPUT

Order InformationLOAD RATINGS

Power Packs B230E-P 220-240VAC, 50/60Hz 20 13 1 24VDC; 150mA*

S120/277/ 347E-P 120/277/347VAC 20/20/15 13/-/- 1/-/- -

Auxiliary Packs

* Output is 150mA before relay is connected and 114mA after relay is connected.

GUARANTEE

5All WattStopperoccupancy sensorscome with a 5-yearguarantee

Page 20: Watts Topper

Jakarta :SetiabudiBuildingIILt.6Suite603Jl.H.R.RasunaSaid,Kav62Jakarta12920Telp :(021)5250608(Hunting)Fax :(021)5255935E-mail :[email protected]

Surabaya :KomplekRukoPanjiMakmurBlokB37Jl.RayaPanjangJiwo46-48Surabaya60299Telp. :(031)8478768,8480972Fax. :(031)8478736E-mail :[email protected]

Medan :Jl.SisingamangarajaNo.88-AMedan20213Telp. :(061)7322566,7323454Fax. :(061)7323454E-mail :[email protected]

Bandung :Komp.SetrasariPlazaII/A11Bandung40152Telp. :(022)2020751Fax. :(022)2011460E-mail :[email protected]

Visit our showrooms