26
Wolf New Generation Design Guide

Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

  • Upload
    lymien

  • View
    218

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

Wolf New Generation Design Guide

Page 2: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

Features and specifications are subject to change at any time without notice. Visit wolfappliance.com/specs for the most up-to-date information.

IMPORTANT NOTE: Throughout this guide, dimensions may vary by ± 1/8" (3). Dimensions in parentheses are millimeters unless otherwise specified.

Contents

3 E Series Ovens

8 Microwave Ovens

14 Electric Cooktops

21 Gas Cooktops

25 Wolf Warranty

Page 3: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 3

WOLF E SERIES OVENS

24" E Series Oven

The Wolf E series lineup now offers a new 24" wide model for kitchens where space is limited. Smart technology gives E series ovens ten cooking modes, with convection fan for even heating, helping to create great meals with ease. Wolf E series ovens are crafted of stainless steel. Tubular handles match the rest of the new Wolf cooking appliance offering, providing a more cohesive family look. The 24" E series oven can be installed in a standard or flush inset application.

KEY FEATURES

• Convection fan for even heat distribution.

• Ten cooking modes for precise, easy-to-use control.

• Self-cleaning oven.

• Full-extension bottom rack for easier access to foods.

• Balanced door hinge system for smooth opening and closing of the door.

24" E SERIES OVEN

TRANSITIONAL

WARM LIGHT TEMP MODE TIMER TIME OFFOK

SO24TE/S/TH

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

Page 4: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

4 | Wolf Customer Care 800.222.7820

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

WOLF E SERIES OVENS

24" E Series Oven

TRANSITIONAL

OPEN OVEN DOOR

211/2" (546)BEHIND FRAME

231/2"(597)

231/4"(591)

21/2"(64)

22"(559)

181/8"(460)

7/8"(22)

231/2"(597)

WARM LIGHT TEMP MODE TIMER TIME OFFOK

Page 5: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 5

WOLF E SERIES OVENS

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

Planning Information

The 24" E series oven can be installed in a standard or flush inset application. If a cooktop is being installed above an oven, a minimum of 1/4" (6) is required between units. Loca-tion of the electrical supply within the oven opening may require additional cabinet depth.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 1/4" (6) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

24" E Series Oven 150 lb (68 kg)

TRIM OVERLAP

Top 1/4" (6)

Bottom 0" (0)

Sides 11/16" (17)

ELECTRICAL

Installation must comply with all applicable electrical codes.

Locate the electrical supply flush with the back wall and within the shaded area shown in the illustrations on the following pages. For ease of installation, the electrical supply for the oven can be placed in an adjacent cabinet within reach of the conduit.

Performance may be compromised if the electrical supply is less than 240 volts.

The 24" oven comes equipped with a standard NEMA 6-20P style plug. Refer to the illustration below for minimum power cord plug clearance.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 240/208 VAC, 60 Hz

Service 20 amp dedicated circuit

Receptacle NEMA 6-20R grounding-type

Power Cord 6' (1.8 m)

3"(76)

MINIMUM CORDCLEARANCE

Power cord clearance.

Page 6: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

6 | Wolf Customer Care 800.222.7820

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

WOLF E SERIES OVENS

24" E Series Oven

STANDARD INSTALLATION

FRONT VIEWSIDE VIEW

NOTE: Electrical supply must be located in adjacent cabinet within 3' (.9 m) of opening.

231/4"(591)

OPENINGHEIGHT

221/2"(572)

OPENINGDEPTH

TOP VIEW

221/8" (562)OPENING WIDTH

EE

Page 7: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 7

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

233/4" (603)FLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

23" (584)FLUSHINSETDEPTH7/8" (22)

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.

NOTE: Electrical supply must be located in adjacent cabinet within 3' (.9 m) of opening.

233/4"(603)

FLUSH INSETHEIGHT**

3/8" (10)

1/8" (3)

TOP VIEW

EE

13/16" (21)

FINISHEDCLEATS*

24" E Series Oven

FLUSH INSET INSTALLATION

WOLF E SERIES OVENS

Page 8: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change
Page 9: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 9

WOLF MICROWAVE OVENS

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

Drop Down Door Microwave Ovens

As true cooking instruments, Wolf microwave ovens have features that make fast meals better meals. New drop down door microwaves feature a door that hinges at the bottom for easier access to foods. Available in 24" and 30" widths, they are designed to match Wolf transitional, professional and contemporary products. Drop down door microwaves can be installed in a standard or flush inset application.

KEY FEATURES

• Distinct styles compliment the look of Wolf ovens.

• Bottom-hinged door.

• Large-capacity interior.

• Sensor cooking to monitor and adjust settings.

• Warming feature for gentle heating.

• Reheat setting is perfect for leftovers.

DROP DOWN DOOR MICROWAVES

TRANSITIONAL

MDD30TE/S/TH

MDD30TM/S/TH

PROFESSIONAL

CONTEMPORARY

MDD30PE/S/PH

MDD30PM/S/PH

MDD30CM/B/TH

MDD24TE/S/TH

Page 10: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

10 | Wolf Customer Care 800.222.7820

WOLF MICROWAVE OVENS

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

211/2" (546)BEHIND FRAME

OPEN OVEN DOOR

177/8"(454)

21/2"(64)

143/16"(360)

7/8"(22)

213/16"(538)

171/2"(446)

WWIDTH

WIDTH

TRANSITIONAL W

24" Model 231/2" (597)

30" Model 297/8" (759)

Drop Down Door Microwave Ovens

TRANSITIONAL

PROFESSIONAL

OPEN OVEN DOOR

177/8"(454)

171/2"(446)

31/4"(83)

213/16"(538)

143/16"(360)

7/8"(22)

297/8"(759)

211/2" (546)BEHIND FRAME

CONTEMPORARY

211/2" (546)BEHIND FRAME

OPEN OVEN DOOR

177/8"(454)

21/2"(64)

143/16"(360)

7/8"(22)

213/16"(538)

171/2"(446)

297/8"(759)

Page 11: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 11

WOLF MICROWAVE OVENS

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

Planning Information

The drop down door microwave oven can be installed in a standard or flush inset application.

Finish the edges of the opening. They may be visible when the door is open.

For standard installations, face trim will overlap stiles and rails. Refer to the chart below.

For flush inset installations, a minimum 1/8" (3) reveal is required on all sides. To ensure consistent reveals, each corner of the opening must be exactly 90°.

INSTALLATION REQUIREMENTS

BASE SUPPORT MIN

Drop Down Door Microwave 100 lb (45 kg)

TRIM OVERLAP 24" MODEL 30" MODEL

Top 3/16" (5) 3/16" (5)

Bottom 0" (0) 0" (0)

Sides 11/16" (18) 37/8" (98)

ELECTRICAL

Installation must comply with all applicable electrical codes.

Locate the electrical supply as shown in the illustrations on the following pages. The receptacle may also be located in an adjacent cabinet within reach of the power cord. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Refer to the illus-tration below for minimum power cord plug clearance.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 15 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 4' (1.2 m)

3"(76)

MINIMUM CORDCLEARANCE

Power cord clearance.

Page 12: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

12 | Wolf Customer Care 800.222.7820

WOLF MICROWAVE OVENS

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

Drop Down Door Microwave Oven

STANDARD INSTALLATION

E

FRONT VIEWSIDE VIEW

NOTE: 24" (610) and 30" (762) models require the same opening dimensions.

1711/16"(449)

OPENINGHEIGHT

219/16"(548)

OPENINGDEPTH

TOP VIEW

WOPENING WIDTH

OPENING WIDTH

DROP DOWN DOOR MICROWAVE W

24" Model 221/8" (562)

30" Model 221/8" (562)

Page 13: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 13

WOLF MICROWAVE OVENS

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

Drop Down Door Microwave Oven

FLUSH INSET INSTALLATION

E

WFLUSH INSET WIDTH**

FRONT VIEWSIDE VIEW

23" (584)FLUSH INSET

DEPTH7/8" (22)

*Will be visible and should be finished to match cabinetry.**Dimension provides minimum reveals.

181/8"(460)

FLUSH INSETHEIGHT**

5/16" (8)

1/8" (3)

A

TOP VIEW

FINISHEDCLEATS*

FLUSH INSET WIDTH

DROP DOWN DOOR MICROWAVE W A

24" Model 233/4" (603) 13/16" (21)

30" Model 301/8" (765) 4" (102)

Page 14: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

14 | Wolf Customer Care 800.222.7820

Page 15: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 15

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

WOLF ELECTRIC COOKTOPS

Electric Cooktops

Sleek. Minimal. And let’s not forget powerful and precise. Wolf electric cooktops offer two modern, refined looks—transitional and contemporary. All the elements feature a true simmer setting that hold sauces and stews below the boiling point. One element includes an even lower one-touch melt setting. Transitional models have stainless steel trim. Contemporary models can be mounted flush with the countertop.

KEY FEATURES

• Ceran glass-ceramic surface for scratch resistance and easy cleaning.

• High-frequency pulsation technology for more even heating.

• Touch controls, invisible when the cooktop is off, display an intuitive power scale for precise control.

• True simmer setting prevents scorching.

• Melt setting on one element for gentle heat.

• Dual and triple elements to customize heat for pans of all sizes.

• Bridge-zone element to create a larger cooking area.

CE365C/B

CE304C/B

CE365T/S

CE304T/S

ELECTRIC COOKTOPS

TRANSITIONAL

CONTEMPORARY

CE152T/S

Page 16: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

16 | Wolf Customer Care 800.222.7820

30" TRANSITIONAL 36" TRANSITIONAL

30" (762)

21"(533)

4" (102)CONDUIT

11/4" (32)

7/8"(22)

36" (914)

21"(533)

4" (102)CONDUIT

11/4" (32)

7/8"(22)

30" CONTEMPORARY 36" CONTEMPORARY

30" (762)

21"(533)

11/4" (32)

31/2" (89)CONDUIT

7/8"(22)

36" (914)

21"(533)

11/4" (32)

31/2" (89)CONDUIT

7/8"(22)

WOLF ELECTRIC COOKTOPS

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

ELEMENT RATING

15" ELECTRIC COOKTOP W

8" (203) Dual 700 / 220051/2" (140) Single 1200

30" ELECTRIC COOKTOP W

101/2" (267) Triple 1050 / 1950 / 2700(2) 51/2" (140) Singles 120061/2" (165) Single with Oval 2400

36" ELECTRIC COOKTOP W

101/2" (267) Triple 1050 / 1950 / 27008" (203) Dual 700 / 220051/2" (140) Single 1200(2) 7" (178) Singles with Bridge 4400

Electric Cooktops

15" TRANSITIONAL

11/4"(32)

CONDUIT

15"(381)

21"(533)

7/8"(22)

31/2" (89)

Page 17: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 17

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

WOLF ELECTRIC COOKTOPS

Planning Information

A minimum 2" (51) is required from the bottom of the cooktop to combustible materials.

Contemporary electric cooktops can be mounted flush with the top of the countertop, or as a frameless standard instal-lation sitting on top of the countertop surface. If the cooktop is to be mounted flush with the countertop, a recessed area surrounding the cooktop cut-out must be provided. Wolf downdraft systems cannot be used with contemporary electric cooktops.

IMPORTANT NOTE: Flush mount installations are intended for granite, solid surface or stone countertop surfaces only.

ELECTRICAL

Installation must comply with all applicable electrical codes.

Locate the electrical supply as shown in the illustrations on the following pages. A separate circuit, servicing only this appliance is required.

Performance may be compromised if the electrical supply is less than 240 volts.

ELECTRICAL REQUIREMENTS

ELECTRIC COOKTOP

Electrical Supply 3-wire, 240/208 VAC, 60 HzConduit flexible 4' (1.2 m)

SERVICE

15" Cooktop 20 amp dedicated circuit30" Cooktop 40 amp dedicated circuit36" Cooktop 50 amp dedicated circuit

Page 18: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

18 | Wolf Customer Care 800.222.7820

WOLF ELECTRIC COOKTOPS

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

15" Electric Cooktop

STANDARD INSTALLATION

14"(356)

191/2"(495)

21/2" (64)

21/2" (64)

FRONT VIEWSIDE VIEW

COUNTERTOP CUT-OUT

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.

13"(330)

18"(457)

E

30"(762)

2"(51)

36" (914) minFLOOR TO

COUNTERTOP

Page 19: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 19

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

WOLF ELECTRIC COOKTOPS

E

COUNTERTOP CUT-OUT

10" (254)

41/2" (114)

31/2" (89)

FRONT VIEWSIDE VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Electrical supply location only applies to installations with built-in oven.

30"(762)

13"(330)

18"(457)

2"(51)

WWIDTH

191/2"(495)

21/2" (64)

21/2" (64)

36" (914) minFLOOR TO

COUNTERTOP

CUT-OUT WIDTH

ELECTRIC COOKTOP W

30" Cooktop 29" (737)

36" Cooktop 35" (889)

30" and 36" Electric Cooktops

STANDARD INSTALLATION

Page 20: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

20 | Wolf Customer Care 800.222.7820

WOLF ELECTRIC COOKTOPS

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

30" and 36" Electric Cooktops

FLUSH INSTALLATION

E

ARECESS

211/8"(537)

RECESS

19/16" (40) min

WCUT-OUT WIDTH

COUNTERTOP CUT-OUT

191/2"(495)

21/2" (64)

21/2" (64)

10" (254)

41/2" (114)

31/2" (89)

FRONT VIEWSIDE VIEW

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Electrical supply location only applies to installations with built-in oven.Outside corner radius 7/16" (11).

30"(762)

13"(330)

18"(457)

2"(51)

5/16" (8)

7/8" (22) MAX

COUNTERTOPPROFILE

36" (914) minFLOOR TO

COUNTERTOP

CUT-OUT WIDTH

ELECTRIC COOKTOP W A

30" Cooktop 29" (737) 301/8" (765)

36" Cooktop 35" (889) 361/8" (918)

Page 21: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 21

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

WOLF GAS COOKTOPS

Contemporary Gas Cooktop

The cooking surface of the Wolf new generation contempo-rary gas cooktop fits flush to the countertop for a striking, low-profile look. Front-mounted controls integrate directly into cabinetry below. New performance enhancements make delicious results even more of a certainty than ever. With a choice of knob colors, the new contemporary gas cooktop offers exceptional design flexibility.

KEY FEATURES

• Dual-stacked, sealed burners for precise control and easy cleanup.

• Flame recognition and automatic reignition for safety and ease of use.

• True simmer setting on all burners prevents scorching.

CG365C/S

GAS COOKTOP

CONTEMPORARY

Page 22: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

22 | Wolf Customer Care 800.222.7820

WOLF GAS COOKTOPS

Gas Cooktop

36" CONTEMPORARY

36" (914)

21"(533)

7/8"(22)

63/4" (171)

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

BURNER RATING

36" GAS COOKTOP BTU (KW)

Large 20,000 (5.9)

Medium 12,000 (3.5)

(3) Small 9,200 (2.7)

Page 23: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

wolfappliance.com | 23

WOLF GAS COOKTOPS

Planning Information

Control knobs for the contemporary gas cooktop are designed to be mounted on the front face of cabinetry below the unit. Mounting holes must be drilled through the cabinet face. Refer to the illustration on the following page for hole location.

A minimum 2" (51) is required from the bottom of the cooktop to combustible materials. If a cooktop is installed above an oven, a minimum of 1/4" (6) is required between units.

ELECTRICAL

Installation must comply with all applicable electrical codes.

Locate the electrical supply as shown in the illustration on the following page. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

ELECTRICAL REQUIREMENTS

Electrical Supply grounded, 120 VAC, 60 Hz

Service 15 amp dedicated circuit

Receptacle 3-prong grounding-type

Power Cord 6' (1.8 m)

RA

NG

ES

/ RA

NG

ET

OP

SO

VE

NS

/ WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLSV

EN

TILAT

ION

CO

OK

TO

PS

/ CO

FF

EE

SY

ST

EM

S

GAS SUPPLY

Installation must conform with all applicable gas codes.

A gas supply line of 3/4" (19) rigid pipe must be provided to the cooktop. If local codes permit, a certified, 3' (.9 m) long, 1/2" (13) or 3/4" (19) ID flexible metal appliance connector is recommended to connect the units 1/2" NPT male inlet to the gas supply line.

Wolf natural gas cooktops will function up to 10,250' (3124 m) in altitude without adjustment and LP gas cooktops will function up to 8,600' (2621 m). If the installation exceeds these elevations, contact an authorized Wolf dealer for a high altitude conversion kit.

GAS REQUIREMENTS

NATURAL GAS WC

Supply Pressure 5" (12.5 mb)

Min Line Pressure 7" (17.5 mb)

Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

LP GAS WC

Supply Pressure 10" (25 mb)

Min Line Pressure 11" (27.4 mb)

Max Regulator Pressure 14" (34.9 mb), .5 psi (3.5 kPa)

Page 24: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

24 | Wolf Customer Care 800.222.7820

Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks of Sub-Zero, Inc. All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.

36" Gas Cooktop

FLUSH INSTALLATION

FRONT VIEWSIDE VIEW

*3" (76) min, 5" (127) max.

NOTE: Shaded area above countertop indicates minimum clearance to combustible surfaces,combustible materials cannot be located within this area.Outside corner radius 3/8" (10).

30"(762)

13"(330)

18"(457)

9"(229)

E G

36" (914)RECESS

21"(533)

RECESS

35" (889)CUT-OUT WIDTH

COUNTERTOP CUT-OUT

20"(508)

21/2" (64)

5/64" (2)

1/2" (13) MAX

COUNTERTOPPROFILE

4" (102)*

5"(127)

C L

10"(254)

11/2" (38)DIAMETER

C L

WOLF GAS COOKTOPS

RA

NG

ES

/ R

AN

GE

TO

PS

VE

NT

ILAT

ION

CO

OK

TO

PS

/ C

OF

FE

E S

YS

TE

MS

OV

EN

S /

WA

RM

ING

DR

AW

ER

SO

UT

DO

OR

GR

ILLS

Page 25: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

Wolf Appliance Residential Limited Warranty

FOR RESIDENTIAL USE

FULL TWO YEAR WARRANTY*

For two years from the date of original installation, this Wolf Appliance product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during normal business hours.

LIMITED FIVE YEAR WARRANTY

For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that prove to be defective in materials or workmanship: gas burners (excludes appearance), electric heating elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction generators. If the owner uses Wolf factory certified service, the service provider will repair or replace these parts with the owner paying for all other costs, including labor. If the owner uses non-certi-fied service, the owner must contact Wolf Appliance, Inc. (using the information below) to receive repaired or replacement parts. Wolf Appliance will not reimburse the owner for parts purchased from non-certified service or other sources.

TERMS APPLICABLE TO EACH WARRANTY

The warranty applies only to products installed for normal residential use. The warranty applies only to products installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.

THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE, INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDEN-TAL DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.

To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf Appliance, Inc., P.O. Box 44848, Madison, WI 53744; check the contact & support section of our website, wolfappliance.com, email us at [email protected] or call 800-222-7820.

*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labor warranty for cosmetic defects.

*Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.

Page 26: Wolf New Generation Design Guidenewgeneration.subzero-wolf.com/Content/WolfAdvancedDesignGuide.pdfWolf New Generation Design Guide. Features and specifications are subject to change

WOLF APPLIANCE, INC. P.O. BOX 44848 MADISON, WI 53744 WOLFAPPLIANCE.COM 800.222.7820

WNGDG 1/2015