15
X-SERIES X-SERIES X-SERIES solar outdoor lighting systems solar outdoor lighting systems Solar Lighting International is the leading manufacturer of the world’s brightest solar light, the X-Series. SLI’s WhiteLighttechnology sets new standards for illumination, security and night-time visibility.

X 5300 350 165 T Specification Sheet

Embed Size (px)

DESCRIPTION

Solar Streetlights 4

Citation preview

Page 1: X 5300 350 165 T Specification Sheet

X-SERIESX-SERIESX-SERIESsolar outdoor lighting systemssolar outdoor lighting systems

Solar Lighting International is the leading manufacturer of the world’s brightest solar light, the X-Series.

SLI’s WhiteLight™ technology sets new standards for illumination, security and night-time visibility.

Page 2: X 5300 350 165 T Specification Sheet

X-5300-350-165-T HID MPPT Solar Lighting System

SOLAR ARRAY

Qty. 1- Top of Pole Solar mounting rack – series 5001 Series

Qty. 2- 165/170/175/180 series watt solar module (Sharp / Sunwize or equal)

Qty. 1 – 15 meter MC Cable to wire array to power center

POWER CENTER

Qty. 1- Aluminum enclosure, pre-wired with keyed lock on front panel

(All enclosures will have the same keyed lock)

Qty. 2- Knockouts with 2 liquid tight strain reliefs included

Qty.1- Solar charge controller, Maximum Power Point Tracking charge controller

Qty. 2- 30A breaker for safety

Qty. 1-Gel battery pack

Qty. 2- 2-24 inch galvanized threaded rod with 4 washers and 4 nuts to mount power

pack to pole

LUMINAIRE – TESTED AT FACTORY PRIOR TO SHIPMENT

Qty. 1- GE MR2C Full cut off Dark Sky compliant cobrahead

Qty. 1- SLI X-50 Ballast and igniter assembly

Qty. 1- X-Series HID 5300 Lumen Metal Halide type light Capsule/ Bulb

Qty. 15 Feet of sunlight resistant 10/2 wire

Pole and Arm sold separately.

Page 3: X 5300 350 165 T Specification Sheet

Series 5001 Single Row 3-Inch Pole Topwith SolarMount® HD RailsInstallation Manual 524.3

Un

irac

Insta

llatio

n M

an

ua

l Se

ries

Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to [email protected].

Pub 090616-4iiJune 2009

© 2009 by Unirac, Inc. All rights reserved.

See www.unirac.com for your nearest Unirac distributor.

Un

irac

Insta

llatio

n M

an

ua

l

U.S. Des. Patent No. D496,249S. Other patents pending.

Stainless steel hardware can seize up, a process called galling. To sig nifi cant ly reduce its like li hood, (1) apply lubricant

to bolts, preferably an anti-seize lu bri cant, avail-able at auto parts stores, (2) shade hardware prior to installation, and (3) avoid spinning on nuts at high speed. See Installation Supplement 910, Galling and Its Prevention, at www.Unirac.com.

The installer is solely re spon si ble for:

• complying with all applicable building codes, including any that supercede these instruc-tions;

• pole installation appropriate to local wind and soil conditions;

• using only Unirac parts and installer-supplied parts as specifi ed by Unirac (substitution of parts will void the warranty);

• installing all electrical aspects of the PV array.

Parts List (Parts are illustrated in exploded views, pp. 2–4.).

Wrench Part Qty. size

SolarMount rail 2Cross pipe 1Pole clamp 2Pole cap 1

Hexhead bolt, 3⁄ 8˝ x 4˝ 4 5⁄8˝ Lock washer, 3⁄ 8˝ 4Saddle 2U-bolt, 3⁄ 8˝ 2Flange nut, 3⁄ 8˝ 4 5⁄8˝

Module mounting clip 4*Module bolt, 1⁄ 4˝ 4* 7⁄16˝ Flat washer, 1⁄ 4˝ 4*Flange nut, 1⁄ 4˝ 4* 7⁄16˝

*Per module to be mounted. Series 5001 racks include clips and hardware to mount 2 to 6 modules.

Thank you for purchasing a Unirac. Please review this manual com plete ly before proceeding.

This rack is intended for a 3-inch (80 mm) Schedule 40 steel pole, outside diameter 3.500 inches (88.9 mm).

Assembly order is not critical. Work from the pole out-ward or attach PV modules to rails before mounting the array to the pole.

Page 4: X 5300 350 165 T Specification Sheet

The SunWize 170/175/180 module falls into the mid-range of price and efficiency and

is aimed at residential and commercial grid-tie applications. It is made of high efficiency

mono-crystalline silicon solar cells. Every cell is tested and electronically matched to

maximize output. The modules are manufactured according to the strict requirements of

international and US quality standards. 25-year limited warranty.

Features include:

Cells are laminated between sheets of ethyl vinyl acetate (EVA) for moisture free

protection, UV stability and electrical isolation

Tempered, high-transmittance glass is used for strength and high power output

The module is framed with a strong, corrosion-resistant clear anodized aluminum with

multiple mounting holes for ease of installation

Modules are equipped with multi-string by-pass diodes so that the modules will function

even if partially shaded

Highly resistant to hail, moisture, wind speed and other environmental factors

Junction box is equipped with + and – MC 3mm (36” male/female) cables

Wide operating range: from -45ºC to 95ºC with 100% relative humidity

US listed to UL-1703, cUL and IEC international standards

SunWize® SW170/175/180 Solar ModuleHigh performance for commercial and residential applications

RELIABLE PEOPLE ::: RELIABLE PRODUCTS ::: RELIABLE POWER

Model Rated Power Rated Voltage Rated Current Open Circuit Short Circuit (Watts) (Vmp) (Imp) Voltage (Voc) Current (Isc)

SW170 170 36.25V 4.69A 43.9V 5.15A

SW175 175 36.50V 4.80A 43.9V 5.20A

SW180 180 36.60V 4.92A 44.0V 5.30A

Standard Test Conditions: 1000 W/m2, 25ºC, AM 1.5

Page 5: X 5300 350 165 T Specification Sheet

SW170/175/180 Solar Module©

SW170/175/180

Dimension inches mm

A 62.20 1580

B 31.81 808

C1 1.65 42

C2 0.53 13

D 31.49 800

E 30.15 766

F .27Ø 7Ø

G 1.25 32

Weight 37.5 lbs. 17 kg. (approx.)

WarrantyThe SunWize SW170 /175/180 module carries a 25-year limited warranty on power output.

CertificationsAll SW modules are UL-1703 and cUL listed and ISPRA certified to international standards.

Electrical Performance

Voltage (V)

Curr

ent (

A)

Electrical / Thermal Parameters

Cell Type Moncrystalline Silicon

Circuit Interconnection 72 – 125 x 125 mm cells, connected in series

Max System Voltage 600Vdc

Series Fuse Rating 12 Amps

NOCT 49ºC

Voltage Temperature coefficient (Voc) -0.34%/ºC

Current Temperature coefficient (Isc) 0.09%/ºC

Power Temperature coefficient (Pmax) -0.37%/ºC

Page 6: X 5300 350 165 T Specification Sheet
Page 7: X 5300 350 165 T Specification Sheet
Page 8: X 5300 350 165 T Specification Sheet
Page 9: X 5300 350 165 T Specification Sheet
Page 10: X 5300 350 165 T Specification Sheet
Page 11: X 5300 350 165 T Specification Sheet
Page 12: X 5300 350 165 T Specification Sheet

R-8/2001

M-2

50 R

OA

DW

AY L

IGH

TIN

G

GE Lighting Systems, Inc.www.gelightingsystems.com

® Registered Trademark of General Electric Company™ Trademark of General Electric Company

Data subject to change without notice

ORDERING NUMBER LOGIC

PRODUCTIDENTXXXX

LIGHTSOURCEX

VOLTAGE

X

BALLASTTYPEX

IES DISTRIBUTIONTYPEXXX

LENS TYPE (PRISMATIC)REFRACTORX

OPTIONS

XXXM2RC =M-250R2 withCutoff Optics

S = HPSC = MercStandard:Lamp notincluded.

60Hz0 = 120/208/

240/277Multivolt

1 = 1202 = 2083 = 2404 = 2775 = 4807 = 120X2408 = 240V

Ballast 120V PEReceptacle notreconnectable

D = 347F = 120X347T = 220W = 230

50Hz6 = 220R = 230Y = 240

NOTE: Dualvoltage connectedfor lower voltage

See Ballast Selection TableA = AutoregC = Merc-RegG = Mag-Reg with

Grounded Socket ShellH = HPF Reactor or LagM = Mag-RegN = NPF Reactor or LagP = CWI with Grounded

Socket Shell

See PhotometricSelection Table

S = ShortM = Medium

C = Cutoff

2 = Type II3 = Type III

See PhotometricSelection TableA = Acrylic Clear

GlobeG = GlassL = Polycarbonate

Clear Globe

NOTE:150 watt Maximumwith Acrylic orPolycarbonateRefractors.

C = Charcoal filterF = Fusing (Not

available withmultivolt or dualvoltage)

J = Line SurgeProtector,Expulsion Type

WATTAGE

XX05 = 5007 = 7010 = 10015 = 150

(55V)17 = 17520 = 20021 = 100/150

(55V)25 = 250

NOTE: Dualwattageconnectedfor lowerwattage

2

PE FUNCTION

X1 = None2 = PE Receptacle

NOTE:Receptacle connectedsame voltage as unitexcept as noted. OrderPE Control separately.

M-250R2 LUMINAIREWITH CUTOFF OPTICS

APPLICATIONS• For residential streets, access roads, parking lots and other outdoor areas

• Universal two-bolt slipfitter• Die-cast aluminum housing with

electrocoat gray paint finish• Adjustable mogul base socket

(street side) – E39 standard• ALGLAS® finish on reflector• No-tool PE receptacle• Plug-in ignitor• True 90° cutoff—no light

above 90° (meets RP8-2000 forfull cutoff)

• External stainless steel baillatch

• CSA Certified unit available,contact factory

• Standard construction is IP55• Plastic Pest guard standard (not

required for 2 in. pipe)

SPECIFICATION FEATURES

All light sources are clear unless otherwise indicated.

PHOTOMETRIC SELECTION TABLE

Light LensWattage Source Type MC2* MC3* SC2*50,70,100,150 (55 V) HPS A or L N/A 9168 (1A) N/A50,70,100,150 (55 V) HPS G 7293(2CL) 7292(1CL) N/A200, 250 HPS G 7306 (2DH) 7305 (1DH) N/A100, 175, 250 Merc G N/A N/A 7300(1B)NOTE: N/A=Not Available

*Meets RP8-2000 for full cutoff

IES Distribution TypePhotometric Curve Number 35-17 ----(Soc Pos)

M2RC 15 S 1 N 2 G MC3 F

Page 13: X 5300 350 165 T Specification Sheet

2001/R-9

M-250 RO

AD

WAY LIG

HTIN

G

GE Lighting Systems, Inc.www.gelightingsystems.com

® Registered Trademark of General Electric Company™ Trademark of General Electric Company

Data subject to change without notice

REFERENCESSee Page R-38 for start of Accessories.See Page R-42 for Explanation of Options and Other Terms Used.See Pole and Bracket Section Page P-2 for pole selection.

DATAApproximate Net Weight 20-30 lbs 9-14 kgsEffective Projected Area

Flat Glass Unit 0.6 sq. ft. max 0.06 sq. M maxClear Acrylic orPolycarbonate Globe Unit 1.0 sq. ft. max 0.09 sq. M max

Suggested Mounting Height 20-40 ft. 6-12 M

M-250R2 LUMINAIREWITH CUTOFF OPTICS

FIXTURE DIMENSIONS

Light Multi- 347, 240/120Wattage Source volt 120 208 240 277 480 120X240 120X347 PE R 220 230 220 230 24050 HPS H,N H,N H,N H,N H,N H,N H,N H,N H,N N/A N/A N/A N/A N/A70,100,150 (55V) HPS A,H,N A,G,H,M,N,P A,G,H,M,N A,G,H,M,N,P A,G,H,M,N G,M G,H,M,N,P G*,H,M*,N G,H,M,N H,M,N N/A H,M,N H N/A100/150 (55V) HPS N/A H,N N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A200, 250 HPS A,P A,H,N,P A,H,N,P A,H,N,P A,P A,P A,P A**,P A,H,N H H A,H,N H H100, 175 Merc C C,N C C,H,N C C C N/A C,H,N N/A N/A N/A N/A N/A250 Merc C A,C,N C C,H,N C C C N/A C,H,N N/A N/A H N/A H

NOTE: N/A = Not AvailableNOTE: *Not available in 120X347 voltNOTE: **Not available in 200 watt

Ballast Type/Voltage60Hz 50Hz

BALLAST SELECTION TABLE

M2AC — SUGGESTED CATALOG ORDERING NUMBERS

Catalog Number Wattage Light Source Voltage Ballast Refractor Photometric(60 Hz) Type Type Distribution

M2RC07S1N2GMC3 070 HPS 120 NPF Reactor Glass MC3M2RC10S1N2GMC3 100 HPS 120 NPF Reactor Glass MC3M2RC15S0A2GMC3 150 HPS 120 NPF Reactor Glass MC3

All GE suggested catalog ordering numbers come with PE receptacle. PE control must be orderedseparately. Order and install SCCL-PECTL if no PE is desired.Multivolt ballasts can be for either 120, 208, 240, or 277 volt incoming power supply.

Page 14: X 5300 350 165 T Specification Sheet
Page 15: X 5300 350 165 T Specification Sheet