Upload
pr3m4n
View
131
Download
27
Embed Size (px)
DESCRIPTION
TELECOM
Citation preview
www.huawei.com www.huawei.com
Huawei XL LTE 1800 MHz SOP Implementation
Huawei Confidential Page 2
Software version
SRAN9.0
NE Name NE Count Target Version (R&D)
BSC6900 GO BSC6900V900R016C00SPC620
BSC6900 UO BSC6900V900R016C00SPC620
BTS3900A_GSM BTS3900 V100R009C00SPC186
BTS3900L_GSM BTS3900 V100R009C00SPC186
M2000 V200R014C00SPC210
CME V200R014C00SPC210
Huawei Confidential Page 3
On Site Operation Process
On site Team : 1. Insert UMPT or replace GTMU with UMPT 2. Insert UBBP slot 3 for GSM only, and slot 2 if WBBP exist in slot 3 3. Upgrade cabinet to Ver. D if scenario using MRFUd, then continue install MRFUd 1800 Mhz 4. Install RRU 3939 if scenario using RRU 5. Reroute CPRI connection based on scenario implementation 6. Cut over transmission to UMPT and new port on RTN/MSTP 7. Download BTS3900 V100R009C00SPCXXX to UMPT (25 minutes) 8. Activate software (10 minutes) 9. SPL software (5 minutes) 10. Download script 11. Activate script 12. Inform to monitoring team whether OM has been Ok or not 13. Dismantle unused materials Monitoring Team : 1. Delete original NE GBTS , Then synchronize NE on U2000 2. Activate eGBTS license dan eNodeB license 3. If existing has 3G, ask RTN/TRM team to reroute IuB vlan service
Huawei Confidential Page 4
Download software to UMPT (20 menit)
Make sure SFTP is running. Double click application below :
Setting IP Laptop: 192.168.0.50 (or 17.21.2.XX) Login via Internet Explorer : IP : 192.168.0.49 (or 17.21.2.15) User name : admin Password : hwbs@com (or NodeB)
Huawei Confidential Page 5
Download software to UMPT (25 minutes)
DLD SOFTWARE: MODE=IPV4, IP="192.168.0.50", USR="admin", PWD="*****", DIR="D:\BTS3900 V100R009C00SPC170_ALL(Software)", SWT=SOFTWARE, SV="D:\BTS3900V100R009C00SPC170", DC=NO, ATL=GBTS&NodeB;
FTP Server IP = IP Laptop Directory Name : address where we save the software
Huawei Confidential Page 6
Activate Software (10 minutes)
ACT SOFTWARE: OT=NE, SWT=SOFTWARE, SV="BTS3900V100R009C00SPC170", ATL=GBTS&NodeB;
Huawei Confidential Page 7
SPL Software (5 Minutes)
SPL SOFTWARE: MODE=IPV4, IP="192.168.0.50", USR="admin", PWD="*****", DIR="D:\BTS3900 V100R009C00SPC170_ALL(Software)", SDL=YES;
Verify SPL software : Run MML command DSP GLOCELL If the MML is not appear, it means SPL software has not succeed
Huawei Confidential Page 8
Software Verification
DSP APP:;
Huawei Confidential Page 9
Download script
DLD CFGFILE: IP="192.168.20.48", USR="admin", PWD="*****", DIR="E:\compt", FN="E720G_3G_KESAWAN_FullExport_20141124022032";
Huawei Confidential Page 10
Activate script
ACT CFGFILE: EFT=AFTER_RESET;
Then Reset UMPT board (From LMT / plug-unplug)
Huawei Confidential Page 11
Check Software Version and Cell Service
• LST VER :; • DSP APP:; • DSP LICENSE: FUNCTIONTYPE=GBTS; • DSP LICENSE: FUNCTIONTYPE=NodeB; • DSP LICINFO:; • CHK DATA2LIC:; • LST ULOCELL: MODE=ALLLOCALCELL; //3G Cell • DSP GLOCELL:; //2G Cell • DSP CELL:; //LTE Cell • Monitor Channel Status and Traffic
Huawei Confidential Page 12
BBU Solution
Before
After
GSM Only
- ADD UMPTb1 (slot 7)
- ADD UBBPd3 (Slot 3)
- ADD UBRI (Optional)
Huawei Confidential Page 13
BBU Solution
Before
After
GU Co-Cabinet
- ADD UMPTb1 (slot 7)
- Move WBBP slot 2 to
slot 4
- ADD UBBPd3 (Slot 2)
- ADD UBRI (Optional)
Huawei Confidential Page 14
RF Solution
Huawei Confidential Page 15
Scenario 1: Existing site is G900 only
Solution : - Keep GTMU - Add DCDU-12B + 3 RRU 3939 (LO) - Add UMPTb1 (LTE Only) slot 7 - Add UBBPd6 slot 3
Existing : - 3 MRFU V2 900MHz - BBU Box : GTMU
BEFORE
Huawei Confidential Page 16
Scenario 1: Existing site is G900 only
Solution : - Keep GTMU - Add DCDU-12B + 3 RRU 3939 (LO) - Add UMPTb1 (LTE Only) slot 7 - Add UBBPd6 slot 3
Existing : - 3 MRFU V2 900MHz - BBU Box : GTMU
AFTER
Huawei Confidential Page 17
Scenario 2: Existing site is D1800 only
Solution : - Add DCDU-12B + 3 RRU 3939 (GL SDR) / MRUFd 1800 - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -Dismantle RRU 3926 / MRFU V2 1800 -Dismantle GTMU -CPRI MUX from UBBPd3 to RRU 3939
Existing : - 3 MRFU V2 1800MHz or RRU 3926 V3 - BBU Box : GTMU
BEFORE
Huawei Confidential Page 18
Scenario 2: Existing site is D1800 only
Solution : - Add DCDU-12B + 3 RRU 3939 (GL SDR) / MRUFd 1800 - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -Dismantle RRU 3926 / MRFU V2 1800 -Dismantle GTMU -CPRI MUX from UBBPd3 to RRU 3939
Existing : - 3 MRFU V2 1800MHz or RRU 3926 V3 - BBU Box : GTMU
AFTER
Huawei Confidential Page 19
Scenario 3: Existing site is G900 + D1800
Solution : - Add DCDU-12B + 3 RRU 3939 (GL) - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -dismantle MRFU V2 OL1 -Keep GTMU for UL interface only -CPRI MUX from UBBPd3 to RRU 3939
Existing : -3 MRFU V2 900MHz + 3 MRFU V2 1800MHz -BBU Box : GTMU
BEFORE
Huawei Confidential Page 20
Scenario 3: Existing site is G900 + D1800
Solution : - Add DCDU-12B + 3 RRU 3939 (GL) - Add UMPTb1 GL co-MPT slot 7 - Add UBBPd3 to slot 3 -dismantle MRFU V2 OL1 -Keep GTMU for UL interface only -CPRI MUX from UBBPd3 to RRU 3939
Existing : -3 MRFU V2 900MHz + 3 MRFU V2 1800MHz -BBU Box : GTMU
AFTER
Huawei Confidential Page 21
Scenario 4: Existing site is G900 + U2100
Existing : -3 MRFU V2 900MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3)
Solution : - Add DCDU-12B + 3 RRU 3939 - Replace GTMU with UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Insert UBBPd3 in slot 2 - dismantle GTMU
BEFORE
Huawei Confidential Page 22
Scenario 4: Existing site is G900 + U2100
Existing : -3 MRFU V2 900MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3)
Solution : - Add DCDU-12B + 3 RRU 3939 - Replace GTMU with UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Insert UBBPd3 in slot 2 - dismantle GTMU
AFTER
Huawei Confidential Page 23
Scenario 5: Existing site is D1800 + U2100
Solution: - Swap cabinet to Ver.D - Replace MRFU V2 to MRFUd 1800 (GL SDR) - Replace GTMU to UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Add UBBPd3 to slot 2 -CPRI MUX from UBBPd3 to MRFUd 1800 -Dismantle GTMU - dismantle old cabinet OL1
Existing : -3 MRFU V2 1800MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3) - BTS3900A Cabinet ver.B
BEFORE
Huawei Confidential Page 24
Scenario 5: Existing site is D1800 + U2100
Solution: - Swap cabinet to Ver.D - Replace MRFU V2 to MRFUd 1800 (GL SDR) - Replace GTMU to UMPTb1 (GL co-MPT) slot 6 - Move existing WBBP slot 2 to slot 4 -Add UBBPd3 to slot 2 -CPRI MUX from UBBPd3 to MRFUd 1800 -Dismantle GTMU - dismantle old cabinet OL1
Existing : -3 MRFU V2 1800MHz + 3 WRFU / RRU 3839 -BBU Box : GTMU , WMPT , WBBP (slot 1-2-3) - BTS3900A Cabinet ver.B
AFTER
HISILICON SEMICONDUCTOR
35pt
: R153 G0 B0
:
LT Medium
: Arial
32pt
: R153 G0 B0
黑体
22pt
) :18pt
黑色
:
LT Regular
: Arial
20pt
):18pt
黑色
细黑体