Transcript
Page 1: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot

Layer 3 Stackable Managed Switch

XGS3-24042 & XGS3-24242

Quick Installation Guide

Page 2: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

Table of Contents

1. Package Contents ....................................................................................... 3

2. Switch Management .................................................................................... 4

3. Requirements ............................................................................................. 5

4. Terminal Setup ........................................................................................... 6

5. Logon to the Console .................................................................................. 8

6. ConfiguringIPAddress ................................................................................ 9

7. Setting1000BASE-XforSFP+Port ..............................................................10

8. Setting100BASE-FXforSFPPort ................................................................10

9. UsingCopperInterfaceonComboPort ........................................................11

10.SavingtheConfiguration ...........................................................................11

11.StartingWebManagement .........................................................................12

12.LoggingintotheManagedSwitch ..............................................................13

13.SavingConfigurationviatheWeb ...............................................................14

14.RecoveringBacktoDefaultConfiguration ....................................................15

15. Customer Support .....................................................................................16

Page 3: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

3

1. Package ContentsThankyouforpurchasingPLANET24-PortGigabitTP/SFP+4-Port10GSFP+Layer3StackableManagedSwitch.Thedescriptionofthismodelisshownbelow:

XGS3-24042Layer 3 24-Port 10/100/1000T + 4-Port 10G SFP+ Stack-ableManagedSwitch

XGS3-24242Layer 3 24-Port 100/1000X SFP with 16-Port shared TP +4-Port10GSFP+StackableManagedSwitch

“Managed Switch” is used as an alternative name in this Quick InstallationGuide.

Open the box of theManaged Switch and carefully unpack it. The box shouldcontainthefollowingitems

� TheManagedSwitchx1

� QuickInstallationGuidex1

� RJ45-to-DB9ConsoleCablex1

� PowerCordx1

� RubberFeetx4

� TwoRack-mountingBracketswithAttachmentScrewsx1

� SFPDustCapx8(XGS3-24042)

� SFPDustCapx28(XGS3-24242)

� QSFP+DustCapx2(XGS3-24242)

If any item is found missing or damaged, please contact your local reseller forreplacement.

Page 4: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

4

2. Switch ManagementTo set up the Managed Switch, the user needs to configure the Managed Switchfornetworkmanagement.TheManagedSwitchprovidestwomanagementoptions:Out-of-Band ManagementandIn-Band Management.

Out-of-Band ManagementOut-of-band management is the management through Console interface.Generally, the user will use out-of-band management for the initial switch configuration,orwhenin-bandmanagementisnotavailable.

In-Band ManagementIn-band management refers to the management by logging in to the ManagedSwitchusingTelnetorHTTP,orusingSNMPmanagementsoftwaretoconfiguretheManaged Switch. In-bandmanagement enables themanagement of theManagedSwitchtoattachsomedevicestotheSwitch.Thefollowingproceduresarerequiredtoenablein-bandmanagement:

1. Logon to console

2.Assign/ConfigureIPaddress

3. Create a remote login account

4.EnableHTTPorTelnetserverontheManagedSwitch

In case in-bandmanagement fails due to Managed Switch configuration changes,out-of-bandmanagement canbeused for configuringandmanaging theManagedSwitch.

Page 5: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

5

3. RequirementsWorkstations runningWindows XP/2003/Vista/7/8/2008/10, MAC OS X or later,Linux,UNIX,orotherplatformsarecompatiblewithTCP/IPprotocols.

WorkstationsareinstalledwithEthernetNIC(NetworkInterfaceCard)

Serial Port Connection(Terminal)

The above Workstations come with COM Port (DB9) or USB-to-RS232converter.

The aboveWorkstations have been installed with terminal emulator, such asTera Term or PuTTY.

Serial cable -- one end is attached to theRS232 serial port,while the otherendtotheconsoleportoftheManagedSwitch.

Ethernet Port Connection

Networkcables--Usestandardnetwork(UTP)cableswithRJ45connectors.

The above PC is installed with Web browser and JAVA runtime environmentplug-in.

Note

It is recommendedtouseInternetExplore8.0orabovetoaccesstheManaged Switch. If theWeb interface of theManaged Switchisnotaccessible,please turnoff theanti-virussoftwareor firewallandthentryitagain.

Page 6: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

6

4. Terminal SetupTo configure the system, connect a serial cable to a COM port on a PC or notebook computer and to serial (console) port of the Managed Switch. Theconsole port of theManaged Switch is DCE already, so that you can connect theconsoleportdirectlythroughPCwithouttheneedofNullModem.

Managed Switch

PC / Workstationwith

Terminal Emulation Software

Serial Port

RS232 to RJ45 Cable

Console PortRJ45

Figure 4-1 Managed Switch Console Connectivity

A terminal program is required tomake the software connection to the ManagedSwitch.TeraTermprogrammaybeagoodchoice.TheTeraTermcanbeaccessedfromtheStart menu.

1. Click STARTmenu,thenPrograms,andthenTera Term.

Page 7: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

7

2.When the following screen appears, make sure that the COM port should beconfiguredas:

Figure 4-2 Tera Term COM Port Configuration

XGS3-24042 XGS3-24242

�Baud:115200 �Baud:9600

�Parity:None �Parity:None

�Databits:8 �Databits:8

�Stopbits:1 �Stopbits:1

�Flowcontrol:None �Flowcontrol:None

Page 8: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

8

5. Logon to the ConsoleOnce the terminal is connected to thedevice,poweron theManagedSwitch,andtheterminalwilldisplay“runningtestingprocedures”.

Then, the following message asks for the login user name and password. Thefactory default user name and password are as follows as the login screen inFigure5-1appears.

Username:adminPassword:admin

Figure 5-1 Managed Switch Console Login Screen

The user can now enter commands to manage the Switch. For a detaileddescriptionofthecommands,pleaserefertothefollowingchapters.

Note

1.Forsecurityreason,pleasechangeandmemorizethenewpass-wordafterthisfirstsetup.

2.Only accept command in lowercase letter under console inter-face.

Page 9: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

9

6.ConfiguringIPAddressThe IP address configuration commands for VLAN1 interface are listed below. Theconfigurationcommandsareasfollows:

XGS3-24042# configXGS3-24042(config)# interface vlan 1XGS3-24042(config-if-Vlan1)# ip address 192.168.1.254 255.255.255.0

ThepreviouscommandwouldapplythefollowsettingsfortheManagedSwitch.

IPv4 Address: 192.168.1.254Subnet Mask: 255.255.255.0

Figure 6-1 Configuring IPv4 Address Screen

To check the current IP address or modify a new IP address for the ManagedSwitch,pleaseusetheprocedureasfollows:

Show the current IP address1. On “XGS3-24042#”prompt,enter“show ip interface brief”.

2.ThescreendisplaysthecurrentIPaddress,subnetmaskandgatewayasshowninFigure6-2.

Figure 6-2 Showing IP Information Screen

If the IP is successfully configured, the Managed Switch will apply the new IPaddresssetting immediately.Youcanaccess theWeb interfaceofManagedSwitchthroughthenewIPaddress.

Note

If you are not familiar with console command or the relatedparameter, enter “help” anytime in console to get the help description.

Page 10: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

10

7.Setting1000BASE-XforSFP+PortThe Managed Switch supports both 10GBASE-X SFP+ transceiver and1000BASE-X SFP transceiver by manual setting and the default SFP+ portspeed is set to 10Gbps. To establish the fiber connection with 1000BASE-X SFPtransceiver,thefollowingcommandconfigurationisrequired:

XGS3-24042#configXGS3-24042(config)#interface ethernet 1/0/25-28XGS3-24042(config-if-port-range)#speed-duplex force1g-full

Figure 7-1 Setting 1000BASE-X Screen

8.Setting100BASE-FXforSFPPortThe Managed Switch supports both 1000BASE-X and 100BASE-FX SFPtransceiversbymanualsettingandthedefaultSFPportspeedissetto1000Mbps.To establish the fiber connection with 100BASE-FX SFP transceiver, the followingcommandconfigurationisrequired:

XGS3-24042#configXGS3-24042(config)#interface ethernet 1/0/21-24XGS3-24042(config-if-port-range)#speed-duplex force100-fx

Figure 8-1 Setting 100BASE-FX Screen

Page 11: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

11

9.UsingCopperInterfaceonComboPortThe Managed Switch’s combo port has SFP and copper interface and the defaultcombo port type is SFP port only. To establish the combo port connection withcopperinterface,thefollowingcommandconfigurationisrequired:

XGS3-24042#configXGS3-24042(config)#interface ethernet 1/0/21-24XGS3-24042(config-if-port-range)#media-type copper

Figure 9-1 Using Copper Interface Screen

10.SavingtheConfigurationIn Managed Switch, the running configuration file stores in the RAM. In thecurrent version, the running configuration sequence running-config can be savedfrom the RAM to FLASH bywrite command or copy running-config startup-configcommand,sothattherunningconfigurationsequencebecomesthestart-upconfigurationfile,whichiscalledconfigurationsave.

XGS3-24042#copy running-config startup-config

Figure 10-1 Copying Running-config Startup-config Screen

Page 12: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

12

11.StartingWebManagementThe Managed Switch provides a built-in browser interface. You can manage itremotely by having a remote host with Web browser, such as Microsoft InternetExplorer,MozillaFirefox,GoogleChromeorAppleSafari.

PC / Workstationwith Web Browser

192.168.0.x

Managed Switch

RJ45/UTP Cable

IP Address:192.168.0.100

Figure 11-1 IP Management Diagram

The following shows how to start-up the Web Management of the ManagedSwitch. Please note the Managed Switch is configured through an Ethernetconnection.PleasemakesurethemanagerPCmustbesettothesameIP subnet address.

For example, the IP address of the Managed Switch is configured with192.168.0.254, then the manager PC should be set to 192.168.0.x (where xis a number between 1 and 253, except 254), and the default subnet mask is255.255.255.0.

ThefactorydefaultManagedIPaddress,usernameandpasswordareasfollows:

DefaultIP:192.168.0.254Username:adminPassword:admin

Page 13: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

13

12.LoggingintotheManagedSwitch1.Use Internet Explorer 8.0 or above Web browser and enter IP address

http://192.168.0.254toaccesstheWebinterface.

2.When the followingdialogboxappears,pleaseenter thedefaultusernameandpassword“admin”.TheloginscreeninFigure12-2appears.

DefaultUsername:adminDefaultPassword:admin

Figure 12-1 Login Screen

3.Afterenteringthepassword,themainscreenappearsasshowninFigure12-2.

Figure 12-2 Web Main Screen of Managed Switch

4.TheSwitchMenuonthe leftoftheWebpage letsyouaccessall thecommandsandstatisticstheSwitchprovides.

Now, you can use the Web management interface to continue the Switchmanagementormanage theManagedSwitchby console interface.Please refer totheusermanualformore.

Page 14: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

14

13.SavingConfigurationviatheWebIn the Managed Switch, the running configuration file stores in the RAM. In thecurrentversion,therunningconfigurationsequenceofrunning-configcanbesavedfrom the RAM to FLASH by “Save current running-configurations” function,so that the running configuration sequencebecomes the startup configurationfile,whichiscalledconfigurationsave.

To save all applied changes and set the current configuration as a startupconfiguration, the startup-configuration file will be loaded automatically across asystemreboot.

1. Click “Switch basic configuration > Switch basic configuration > Save current running-configuration” to login “Save current running-configuration”Page.

2. Press the “Apply” button to save current running-configuration to start upconfiguration.

Page 15: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

15

14.RecoveringBacktoDefaultConfigurationToresettheIPaddressorconfigurationbacktodefaultvalue.

1. Please logon to the console

2.Typethefollowingcommandconfigurationisrequired:

XGS3-24042#setdefaultAreyousure?[Y/N]=Y

3.SavingtheConfiguration,pleasefollowchapter10.

XGS3-24042#copyrunning-configstartup-config

4.Reboottheswitch:

XGS3-24042#reload

Figure 14-1 Set default procedure Screen

Page 16: 24-Port Gigabit TP/SFP + 4-Port 10G SFP+ Slot ... - PLANET

16

15. Customer SupportThank you for purchasing PLANET products. You can browse our online FAQresourceonPLANETWebsitefirsttocheckifitcouldsolveyourissue.Ifyouneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.

PLANETonlineFAQ:http://www.planet.com.tw/en/support/faq.php?type=1

Switchsupportteammailaddress:[email protected]

XGS3-24042andXGS3-24242User’sManualhttp://www.planet.com.tw/en/support/download.php?type1=1&model=&type=3

(PleaseselectyourswitchmodelnamefromtheProductModeldrop-downmenu)

Copyright © PLANET Technology Corp. 2016.Contents are subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.


Recommended