iS7 CC-Link Manual

2

Introduction

The CC-Link Master can operate the VS1AP drive and monitor the state of VS1AP in

the CC-Link network through the VS1AP CC-Link communication option board.

The VS1AP CC-Link option supports version 1.10 of CC-Link.

1. Specification of CC-Link Communication Option Board

2. Product Components

- VS1AP CC-Link communication option board 1 ea

- Screw for fixing on the inverter 1 ea

- VS1AP CC-Link User Manual 1 ea

Transmission

Speed 156k, 625k, 2.5M, 5M, 10Mbps

Station Type Remote device station

Number of

Occupied Stations 1 station

Version V1.10

The Number of

Station connected

(1 X a) + (2 X b) + (3 X c) + (4 X d) โ‰ค 64

a: Number of modules occupying 1 station

b: Number of modules occupying 2 station

c: Number of modules occupying 3 station

d: Number of modules occupying 4 station

(16 X A) + (54 X B) + (88 X C) โ‰ค 2304

A: Number of remote I/O stations ---------------------- Max. 64

B: Number of remote device stations ------------------ Max. 42

C: Number of Local/Intelligent device stations ------ Max. 26

Interface 5 pin pluggable connector

Cable CC-Link dedicated cable,

Compatible dedicated cable with CC-Link Ver 1.10

External Diameter Less than 8.0 mm

Page 5: iS7 CC-Link User Manual

iS7 CC-Link Manual

3

3. Installation of the VS1AP CC-Link Option

(1) The VS1AP CC-Link Option Module

(2) VS1AP CC-Link Option Board Layout

CPU

5Pin Pluggable

ConnectorInverter

Connector

COM

RUN

ERR

CPU

CC-Link

ASIC

Terminal Resistor

Switch

Page 6: iS7 CC-Link User Manual

iS7 CC-Link Manual

4

(3) Mounting the communication option board on VS1AP drive

(4) CC-Link signal connector structure and wiring method

โ‘  DA (Blue) โ‘กDB (White) โ‘ขDG (Yellow) โ‘ฃSLD (Shielded twisted Cable) โ‘ค FG

<Connector Structure> <Wiring Method>

โ€ป Signal connector OSADA OS-86-5P must be used for VS1AP CC-Link

communication option board. (5-Pin connector)

โ‘  โ‘ข โ‘ก โ‘ฃ โ‘ค

CC-Link

Communication

option board

Page 7: iS7 CC-Link User Manual

iS7 CC-Link Manual

5

4. Network Connection

Connection terminal of communication cable

<Setting method of terminal resistor>

โ€ป If the VS1AP CC-Link communication option board is placed at the end of

the network, the last option board must turn On the setting switch of terminal

resistor. Terminal resistor is 110 ฮฉ 1/2W.

No. Signal Description Cable Color

1 DA Transmitted/Received data Blue

2 DB Transmitted/Received data White

3 DG Signal ground Yellow

4 SLD Shielded cable Shielded twisted Cable

5 FG Frame ground -

- Cut off the designated plastic

cover.

- By switching on the switch, the

terminal resistor is set.

Terminal

Resistor Switch

When the switch of terminal resistor is

placed in right side (On)

โ†’ Terminating resistor is used.

When the switch of terminal resistor is

placed in left side (Off)

โ†’ Terminating resistor is not used.

Page 8: iS7 CC-Link User Manual

iS7 CC-Link Manual

6

<Hardware Installation>

Warning) Configure the communication network after turn off the power of inverter

Wiring of CC-Link communication cable

Connect the dedicated CC-Link communication cable to terminal block as

following procedure.

To reduce the noise, CC-Link communication board at both ends of the network

has to be terminated. Turn on the setting switch of terminal resistor on CC-Link

communication board.

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

Blue

White

Yellow

Shielded Twisted Cable

Blue Blue

White White

Yellow Yellow

Shielded Twisted

Cable

Shielded Twisted

Cable

Terminal Resistor: ON

Terminal Resistor: ON

Page 9: iS7 CC-Link User Manual

iS7 CC-Link Manual

7

<Communication Cable Feature>

We recommend the cable as below described cable. If not, we can not guarantee

the performance of CC-Link.

note1) PVF EV-AMESB recommended note2) Measuring Method of Characteristic Impedance

- Cable Length: 100m or more

Measuring method is not designated, but Open/Short method has to measure the

characteristic impedance in range within each specified frequency by approximate

value which is measured value.

Items Specification

Type Shielded twisted cable note1)

The number of Cable

Core 3

Conductor Size 20AWG

Conductor Resistor

(20) 37.8ฮฉ / km or less

Insulation Resistor 10000Mฮฉ / km or more

Withstanding Voltage DC500 V 1 minute

Capacitance

(1 kHz) 60 nF / km or less

Characteristic

Impedancenote2)

1MHz 110 ยฑ 15ฮฉ

5MHz 110 ยฑ 6ฮฉ

Cross Section

DA

Blue

White Yellow

DB

Ground

WireDG

Aluminum

Tape

Sheath

Shielded

External Diameter 7 mm

Page 10: iS7 CC-Link User Manual

iS7 CC-Link Manual

8

<Maximum Transmission Distance>

Master

Station

Slave

Station

Slave

Station

Slave

Station

Slave

Station

Slave

Station

Slave

Station

Maximum Transmission Distance

Terminating Terminating

Maximum Time-Delay for CC-Link Communication

The table below contains the maximum time-delays for each profile that are available

with the CC-Link communication option card. The time-delay is the time taken to

process data and return it to the master PLC.

When the master PLC communication cycle time is less (shorter) than the maximum

time-delay, accurate communication from the CC-Link cannot be guaranteed. To

guarantee communication accuracy, the master PLCโ€™s communication cycle time must

be more (longer) than the maximum time-delay.

Mode Maximum Time-delay for CC-Link Communication

Profile1 80 msec

Profile2 15 msec

Baudrate 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps

Cable Length

between

Stations

20m or more

Max.

Transmission

Distance

1200m 900m 400m 160m 100m

Page 11: iS7 CC-Link User Manual

iS7 CC-Link Manual

9

5. LED Display

3 green LEDs and 1 red LED on the CC-Link communication board displays the

status of CC-Link communication board. LED is organized as following.

LED

Name Color Function

COM Green

On โ€“ Communication transmitting/receiving.

Off โ€“ Communication transmitting/receiving is not established.

Check if the communication cable is connected correctly.

RUN Green

On โ€“ Station ID and Baud Rate is normally set and Refresh data

is received normally.

Off โ€“ CC-Link communication is not established.

Check if COM-09(Station ID) and COM-10(Baud rate) is

set correctly.

ERR Red On โ€“ CRC Error

Off โ€“ Normal State

CPU Green

Flickering at the 1 second interval โ€“ It means that CC-Link

communication board is energized and the status is normal.

Off โ€“ It means that CC-Link communication board is de-

energized or CC-Link communication board has a fault.

Flickering at the 200m second interval โ€“ It means that the

changed value of Station ID and Baudrate is not saved

successfully in internal memory of CPU.

Flickering at the 2 second interval โ€“ It means that the interface

communication between CC-Link communication board and

inverter has an error.

Green

RUN

Red

ERR

Green

COM

Green

CPU

Page 12: iS7 CC-Link User Manual

iS7 CC-Link Manual

10

6. Trouble Shooting

LED Display Cause Countermeasure

COM RUN ERR CPU

OFF OFF OFF OFF Power supply is

not energized.

Check if the communication board is

installed on the inverter. Check if the

inverter is turned On.

- - -

Flickering

with 200m

cycle

Abnormal saving

in internal

memory

Check if communication cable and

power supply cable is separated.

After the power of inverter is turned

Off, and then energize the power of

inverter.

- - - Flickering

with 2 s

Abnormal

Interface

communication

between

communication

board and

inverter

Check if communication cable and

power supply cable is separated.

After the power of inverter is turned

Off, and then energize the power of

inverter.

OFF OFF - Flickering

with 1 s

Communication is

not established.

Check if communication cable is

connected correctly.

- OFF - Flickering

with 1 s

The value of

StationID and

Baudrate is not

correct.

Set the value of Station ID and

Baudrate correctly, and then do

Comm Update.

- ON Flicker

ing

Flickering

with 1 s

After

Communication

board is turned

On, the value of

Station ID and

Baudrate is

changed.

Change the value of Station ID and

Baudrate to the previous value or

Do Comm Update to apply the

changed value of Station ID and

Baudrate.

ON ON Flicker

ing

Flickering

with 1 s

CRC Error

Occurrence

CRC error is occurred by influenced

of noise.

Check if communication cable and

power supply cable is separated.

Page 13: iS7 CC-Link User Manual

iS7 CC-Link Manual

11

7. Quick Communication Start

Install the CC-Link communication board while inverter power supply is turned off.

After inverter power supply turns on, check if CNF-30 parameter is โ€˜CC-Linkโ€™. Connect

to the network with communication cable via CC-Link communication board.

(1) Set the Station ID of inverter at parameter COM-7 FBus ID.

(2) Set Baudrate at COM-10 Opt .

(3) Set to โ€˜Yesโ€™ at COM-94 Comm Update.

Check if RUN LED of CC-Link Communication board is turned On. If not, Check if

the parameter value of COM-7 and COM-1 of Keypad is correct.

Page 14: iS7 CC-Link User Manual

iS7 CC-Link Manual

12

8. Keypad Parameter related with CC-Link Communication

Code Parameter Name Initial Value Range

CNF-30 Option-1 Type - -

DRV-06 Cmd Source Fx/Rx-1

Keypad

Fx/Rx-1

Fx/Rx-2

Int. 485

FieldBus

PLC

DRV-07 Freq Ref Src Keypad-1

Keypad-1

Keypad-2

V1

I1

V2

I2

Int. 485

Encoder

FieldBus

PLC

PRT-12 Lost Cmd Mode None

None

FreeRun

Dec

Hold Input

Hold Output

Lost Preset

PRT-13 Lost Cmd Time 1.0sec 0.1~120.0sec

PRT-14 Lost Preset F 0.00Hz 0.00~400.00Hz

COM-06 FBus S/W Ver - -

COM-07 FBus ID 1 0~64

COM-09 FBus LED - -

Page 15: iS7 CC-Link User Manual

iS7 CC-Link Manual

13

(1) Option-1 Type (CNF-30)

It displays the name of communication board installed on the inverter.

It displays โ€˜CC-Linkโ€™ when CC-Link communication board is installed correctly

and there is no fault.

(2) Cmd Source (DRV-06)

It sets the run command source of inverter

The parameter sets to โ€˜Fieldbusโ€™ when it commands Run/Stop operation to

inverter by CC-Link communication.

(3) Freq Ref Src (DRV-07)

It sets the frequency command source of inverter.

The parameter sets to โ€˜Fieldbusโ€™ when it commands Command frequency by

CC-Link communication.

Code Parameter Name Initial

Value Range

COM-10 Opt Parameter1 0

0 (156k)

1 (625k)

2 (2.5M)

3 (5M)

4 (10M)

COM-31

~COM-38

Para Status-1

~ Para Status-8 - 0x0000 ~ 0xFFFF

COM-51

~COM-58

Para Control-1

~ Para Control-8 - 0x0000 ~ 0xFFFF

COM-94 Comm Update No No

Yes

Page 16: iS7 CC-Link User Manual

iS7 CC-Link Manual

14

(4) Lost Cmd Mode (PRT-12)

It designates the Run mode when Lost Command is occurred during the time of

PRT-13 Lost Cmd Time.

None: It does anything when Lost Command is occurred.

FreeRun: After the status of inverter is changed to Lost Command, motor will free-run to

stop and Trip will be occurred.

Dec: After the status of inverter is changed to Lost Command, motor will decelerate to

stop and Lost Command Stop will be occurred.

Hold Input: Running with the last Run command and Lost Command Warning will be

occurred.

Hold Output: Running with the current run speed and Lost Command Warning will be

occurred.

Lost Preset: Running with the preset value of PRT-14 and Lost Command Warning will

be occurred.

(5) Lost Preset F (PRT-14) โ€“ Lost Preset Frequency

When PRT-12 Lost Cmd Mode is set to Lost Preset, inverter will operate with

the frequency which is set in Lost Preset F at Lost Preset Frequency occurred.

(6) Lost Cmd Time (PRT-13) โ€“ Decision time of Lost Preset Frequency

If Preset Frequency is lost for the preset time of PRT-13 Lost Cmd Time, it is

recognized to Lost Preset Frequency.

If the communication is restored within the time of PRT-13 Lost Cmd Time, it is

not recognized to error.

Lost

Command

Lost

Command

PRT-13

Lost Cmd Time

PRT-13

Lost Cmd Time

Recognition of

Lost Command

The status of

Communication

Page 17: iS7 CC-Link User Manual

iS7 CC-Link Manual

15

(7) FBus S/W Ver (COM-06)

It displays the version of communication board installed on the inverter.

(8) FBus ID (COM-07) โ€“ Station Number setting

It sets the Station ID of CC-Link. It can set Station Number from 0 to 64.

Station ID can not be duplicated. Check if Station ID is not duplicated.

The value of Station ID will be applied to CC-Link option board after Comm

Update sets to โ€˜YESโ€™.

Caution

Example of network connection)

Same station numbers can not be used more than once in a network.

Set the station number sequentially in order of connection. (Do not create a

dead station as station 1, station 2, and station 4.)

(9) FBus LED (COM-09) โ€“ LED display for On/Off

It displays the status information of CC-Link communication.

It displays 4 LEDs at COM-0 FBus LED.

LED status is displayed at COM-9 FBus LED parameter by keypad. 3 LEDs

among 4 LEDs displayed indicates the status of CC-Link communication option

board. It displays the information about CPU status, Inverter Interface

disconnection and failure of saving the Station ID and Baud Rate to EEPROM in

order of from right to left.

Station1 Station2 Station3 Station4

CC-Link Master FBus ID 1 FBus ID 2 FBus ID 3 FBus ID 4

Station0

Page 18: iS7 CC-Link User Manual

iS7 CC-Link Manual

16

Example of COM-09 LED status)

(10) Opt Parameter1 (COM-10) โ€“ Baud Rate setting

It sets the parameter of Baudrate of CC-Link communication. It can be set from

0 (156 Kbps) to 4 (10 Mbps).

The value of Baudrate will be applied to CC-Link option board after Comm

Update sets to โ€˜YESโ€™.

(11) Para Status-1~8 (COM-31~38)

It sets the inverter address to read in Para Status 1~8 when read operation of

command code RWw2 of remote register is executed.

It describes the method to read the Para Status 1~8 with command code RWw2.

Input of the value of RWw2 is described as shown in the figure below. To

access to Status, the value of Nibble 3, Nibble 2 and Nibble 1 must be 0.

Nibble 0 determines which value of status will be read among Para Status 1~8.

If the value of Nibble 0 is 0, it is Para Status-1. If the value of Nibble 0 is 1, it is

Para Status-2.

For example, If RWw2 sets to 0x0003, the saved value in address which is set

in Para Status-4 will be read.

Bit Description Status Causes of Status

0

1

2

3

CPU LED

ERR LED

RUN LED

COM LED

Flicker Normal communication

On or Flicker Fault has occurred.

On Communication is established.

On Data is transmitting and receiving.

COM LED RUN LED ERR LED CPU LED

OFF OFF ON OFF

Page 19: iS7 CC-Link User Manual

iS7 CC-Link Manual

17

3 2 1 0 (Nibble, 4Bit)

0 : Read1 : Write

0

0~7 (Status/Control Number)

< RWw2 >

0

(12) Para Control1~8 (COM-51~58)

It sets the inverter address to write in Para Control 1~8 when write operation of

command code RWw2 of remote register is executed.

It describes the method to write the Para Control 1~8 with command code

RWw2.

The value of Nibble 3 must be 1 (Write) to write Control.

The value of Nibble 2 and 1 must be 0.

Nibble 0 determines which value of status will be written among Para Control

1~8. If the value of Nibble 0 is 0, it is Para Control-1. If the value of Nibble 0 is 1,

it is Para Control-2.

For example, If RWw2 sets to 0x1004, the saved value in address RWw3 which

is set in Para Status-5 will be written.

(13) Comm Update (COM-94)

The value of COM-07 FBus ID and COM-10 Opt Parameter 1 will be applied to

CC-Link option board after Comm Update sets to โ€˜YESโ€™.

The changed Station ID and communication speed will be applied to CC-Link

option board after Comm Update sets to โ€˜YESโ€™.

9. CC-Link Data List

Inverter occupies the buffer memory 1 station of master.

It means the input/output data information between master and inverter.

Page 20: iS7 CC-Link User Manual

iS7 CC-Link Manual

18

9.1 Details of Remote Input and Output Signals

Remote Output Signals

(Master unit to Inverter)

Remote Input Signals

(Inverter to Master unit)

Device No. Signal Function Device No. Signal Function

RY0 Forward running

command RX0 Forward running

RY1 Reverse running

command RX1 Reverse running

RY2~8 N/A

RX2 Accelerating

RX3 Decelerating

RX4 Reach to preset speed

RX5 DC Braking

RX6 N/A

RX7 Relay1 output terminal

RX8 Relay2 output terminal

RY9 Output stop RX9 Q1 output terminal

RYA~B N/A RXA N/A

RXB N/A

RYC Monitor command RXC Monitoring

RYD

Frequency setting

command 1

(RAM)

RXD

Frequency setting

completion 1

(RAM)

RYE

Frequency setting

command 2

(EEPROM)

RXE Frequency setting

completion 2

RYF Instruction code

execution request RXF

Instruction code execution

completion (EEPROM)

RY10~19 N/A RX10~19 N/A

RY1A Error reset request flag RX1A Error status flag

RY1B N/A RX1B Available status to run

RY1C~1F System reservation RX1C~1F System reservation

Page 21: iS7 CC-Link User Manual

iS7 CC-Link Manual

19

9.2 Remote output

Remote Output Signals (Master to Inverter)

Device

No. Signal Function Description

RY0 Forward running

command

ON Forward running start

OFF Stop command

RY1 Reverse running

command

ON Reverse running start

OFF Stop command

RY2~8 N/A -

RY9 Interrupting of

inverter output When it turns On, motor free-run to stop.

RYA~B N/A -

RYC Monitor command

When monitor command (RYC) is switched On, the

corresponding monitor value to RWw1 is saved in

RWr1. RXC (Monitoring) switches On.

RYD

Frequency setting

command 1

(RAM)

When frequency setting command 1 (RYD) is

switched On, command frequency (RWw1) is

written to RAM of the inverter. Frequency setting

completion 1 (RXD) is turned On after completion of

write.

RYE

Frequency setting

command 2

(RAM, EEPROM)

When the frequency setting command (RYE) is

switched on, the set frequency (RWw1) is written to

RAM and EEPROM of the inverter. On completion

of write, frequency setting completion (RXD)

switches on. The set frequency is remained even if

power of inverter is switched On/Off.

RYF

Request for

command code

execution

It requests the execution of the command code

(RWw2). In case command code is Write request,

the value of RWw3 is valid.

RY10~19 N/A -

RY1A Inverter Reset

If an inverter has a fault, RY1A is switched On. It

makes that the inverter is reset to remove the trip

after removing the cause of the fault.

RY1B N/A -

RY1C~1F System reservation -

Page 22: iS7 CC-Link User Manual

iS7 CC-Link Manual

20

9.3 Remote Input

Remote Input Signals (Inverter to Master)

Device

No. Signal Function Description

RX0 Forward running

command

ON Forward running

OFF Other than forward running

(during stop or reverse running)

RX1 Reverse running

command

ON Reverse running

OFF Other than reverse running

(during stop or forward running)

RX2 Accelerating Accelerating when it is turned On

RX3 Decelerating Decelerating when it is turned On

RX4 Reach to preset

speed Reach to preset speed when it is turned On

RX5 N/A -

RX6 N/A -

RX7 Relay1 output

terminal Terminal output when it is turned On

RX8 Relay2 output

terminal Terminal output when it is turned On

RX9 Q1 output terminal Terminal output when it is turned On

RXA N/A -

RXB N/A -

RXC Monitoring

Switched On when monitor data is updating.

When the monitor command (RYC) is switched

On, the monitor value (RWw0) is set to RWr0 and

monitoring (RXC) switches On. Switched Off

(RXC) when the monitor command (RYC) is

switched Off.

RXD

Frequency setting

completion 1

(RAM)

Switched On (RXD) when the set frequency is

written to the inverter by frequency setting

switching On (RYD).

RXE Frequency setting

completion 2

Switched On (RXE) when frequency command is

written to the inverter by Frequency setting

Page 23: iS7 CC-Link User Manual

iS7 CC-Link Manual

21

Remote Input Signals (Inverter to Master)

Device

No. Signal Function Description

(EEPROM) command 2 (RYE) switching ON.

RXF Instruction code

execution completion

When the instruction code execution request

(RYF) is switched on, processing corresponding to

the instruction code set to RWw2is executed.

The instruction code execution completion (RXF)

is switched On after completion of execution of

instruction code. When an instruction code

execution error occurs, a value other than โ€˜0' is set

in the reply code (RWr2).

RX10~19 N/A -

RX1A Trip status It turns On when the trip of inverter has occurred.

RX1B Available status to

run

It turns On when the inverter can be available. It

means that the inverter power is supplied stably

and there is no fault.

RX1C~1F System reservation -

Page 24: iS7 CC-Link User Manual

iS7 CC-Link Manual

22

9.4 Remote Register

(Master to Inverter)

Remote

Register Name Description

Request

for

Execution

RWw0 Monitor

code

Set the monitor code to be referenced. By

switching On the monitor command flag

(RYC), the corresponding to monitored data is

written set to RWr0 and Monitoring (RXC)

switches On.

RYC

RWw1

Set

frequency

(0.01 Hz

Scale)

Specify the set frequency. At this time, when

Frequency setting command 1 (RYD) is

switched On, it is stored in RAM of the inverter.

When Frequency setting command 2 (RYE) is

switched On, it is stored in EEPROM that it

can save the set frequency even if power is

switched Off and then On.

To command the frequency through

communication, Ref Freq Src of DRV-07 must

be set to โ€˜Fieldbusโ€™.

RYD RYE

RWw2 Command

code

Set the command code for execution of read/

write/ error history/ error reset, etc. of

parameter.

The corresponding process to command code

(RWw2) is executed by switching On

command code execution request flag (RYF)

after completion of command code (RWw2)

setting. Command code execution completion

flag (RXF) switches On after completion of

command execution.

When command code is Write, the data of

Write set in RWw3.

RYF

RWw3 Write data

Command code execution request flag (RYF)

switches On after setting of Write data and

command code.

Page 25: iS7 CC-Link User Manual

iS7 CC-Link Manual

23

(Inverter to Master)

Remote

register Name Description

Request

for

execution

RWr0 Monitor data

Monitor value specified to the upper Byte of

RWw0 of monitor code is set in RWr0 and

Monitoring (RXC) switches On.

RYC

RWr1 Output

frequency - RYD RYE

RWr2 Reply code

When Command code (RWw2) and Write

data (RWw3) is normal, 0x00 is set in reply

code (RWr2). If not, the value from 0x01 to

0x03 is set in replay code. RYF

RWr3 Read data When command code (RWw2) is Read, the

corresponding read data is set.

Page 26: iS7 CC-Link User Manual

iS7 CC-Link Manual

24

9.5 Monitor code

Instance ID Object Name

Unit Upper 1Byte Lower 1Byte

0x00 Not monitor 0.01 Hz

0x01 Output frequency 0.01 Hz

0x02 Output current 0.01 A

0x03 Output voltage 1V

0x04 N/A

0x05 Preset frequency 0.01Hz

0x06 Run speed 1 rpm

0x07 Motor output torque 0.1%

0x08 DC Link voltage 1 V

0x09~0x0D N/A

0x0E Output electric power 0.1kW

0x0F Status of input terminal Note1)

0x10 Status of output terminal Note2)

0x11~0x15 N/A

0x16 Run status of inverter Note3)

0x17 Run time of inverter Hour

Note1) Bit information of input terminal

- - - P11 P10 P9 P8 P7 P5 P4 P3P6 P2 P1

13 12 11 10 9 8 7 6 4 3 25 0

RWr3

1

- -

15 14

When status of each input terminal is turned On, the value is 1.

When status of each input terminal is turned Off, the value is 0.

Page 27: iS7 CC-Link User Manual

iS7 CC-Link Manual

25

Note2) Bit information of output terminal

- - - - - - - - Q3 Q2 Q1Q4 R2 R1

13 12 11 10 9 8 7 6 4 3 25 0

RWr3

1

- -

15 14

When status of each output terminal is turned On, the value is 1.

When status of each output terminal is turned Off, the value is 0.

R1 means Relay1 and R2 means Relay2.

Note3) Bit information of inverter run status

B15 0 : Normal status

4 : Warning occurrence

8 : Fault occurrence

(It operates according to the value of PRT-30 Trip Out Mode.)

B14

B13

B12

B11

- B10

B9

B8

B7 1 : Speed Searching 2 : Accelerating

3 : Constant speed 4 : Decelerating

5 : Deceleration to stop 6 : H/W OCS

7 : S/W OCS 8 : Dwell operation

B6

B5

B4

B3 0 : Stop

1 : Forward running

2 : Reverse running

3 : DC operation (Zero speed control)

B2

B1

B0

Page 28: iS7 CC-Link User Manual

iS7 CC-Link Manual

26

9.6 Command Codes

(1) Profile 1 Command Code

The diagram below shows the command code information when COM-11 Opt Parameter2 is

set to 0 (Profile1).

Set the command code to the remote register. The command code is read, the relevant

operation runs, and the resulting value is saved at the remote register RWw.

3 2 1 0 (Nibble, 4Bit)

0 : Read1 : Write

0

0~7 (Status/Control Number)

< RWw2 >

0

Inverter command codes are in two categories: read and write.

To run read commands, assign values between 0x0000โ€“0x0007 to RWw2. The inverter data

located at the addresses specified in COM 31-38 Para Status1- 8 are read.

To run write commands, assign values between 0x1000 -0x1007 to RWw2. The value stored at

RWw3 will be written to the inverter addresses specified in COM 51-58 Para Control1โ€“8.

(2) Profile 2 Command Code

Inverter command codes are in two categories: read and write.

To run read commands assign the inverter communication address to RWw2.

To run write commands, set the most significant bit (MSB) of the inverter communication

address, and assign it to RWw2. Then, input the data to be written at RWw3.

For example, to read the value set for DRV-03 Acc Time through a command code, input

0x1103 at RWw2. Then, to set DRV-03 Acc Time to 50.0 seconds using a command code, input

0x9103 (the MSB is set) at RWw2, and then input 500 at RWw3.

Page 29: iS7 CC-Link User Manual

iS7 CC-Link Manual

27

9.7 Error Codes

The table below lists the error codes that are set response of monitoring and command codes

to RWr2.

Error

code Description Cause of error

0x00 Normal A command code received from the master PLC has

been correctly executed.

0x01 Write mode error An unapproved value was written in the monitor code

(RWw0) or in the command code (RWw2) register.

0x02 Invalid command error Invalid address input at COM 31-37, Status1-8 or COM

51-58, Control1-8.

0x03 Write data range error Write values outside of the approved range were used.

0x04 Write-protected area

error

An attempt to write to a write-protected area was made.

Page 30: iS7 CC-Link User Manual

iS7 CC-Link Manual

1

์ œํ’ˆ์„ ์‚ฌ์šฉํ•˜๊ธฐ ์ „์—

๋จผ์ € ์ €ํฌ CC-Link ์˜ต์…˜๋ณด๋“œ๋ฅผ ์‚ฌ์šฉํ•˜์—ฌ ์ฃผ์…”์„œ ๊ฐ์‚ฌํ•ฉ๋‹ˆ๋‹ค.

์•ˆ์ „์ƒ์˜ ์ฃผ์˜์‚ฌํ•ญ

์•ˆ์ „์ƒ์˜ ์ฃผ์˜์‚ฌํ•ญ์€ ์‚ฌ๊ณ ๋‚˜ ์œ„ํ—˜์„ ์‚ฌ์ „์— ์˜ˆ๋ฐฉํ•˜์—ฌ ์ œํ’ˆ์„ ์•ˆ์ „ํ•˜๊ณ  ์˜ฌ๋ฐ”๋ฅด๊ฒŒ

์‚ฌ์šฉํ•˜๊ธฐ ์œ„ํ•œ ๊ฒƒ์ด๋ฏ€๋กœ ๋ฐ˜๋“œ์‹œ ์ง€์ผœ์ฃผ์‹ญ์‹œ์˜ค.

์ฃผ์˜์‚ฌํ•ญ์€ โ€˜๊ฒฝ๊ณ โ€™์™€ โ€˜์ฃผ์˜โ€™์˜ ๋‘ ๊ฐ€์ง€๋กœ ๊ตฌ๋ถ„๋˜์–ด ์žˆ์œผ๋ฉฐ โ€˜๊ฒฝ๊ณ โ€™์™€ โ€˜์ฃผ์˜โ€™์˜ ์˜๋ฏธ

๋Š” ๋‹ค์Œ๊ณผ ๊ฐ™์Šต๋‹ˆ๋‹ค.

๊ฒฝ ๊ณ 

์ฃผ ์˜

์ œํ’ˆ๊ณผ ์‚ฌ์šฉ์„ค๋ช…์„œ์— ํ‘œ์‹œ๋œ ๊ทธ๋ฆผ๊ธฐํ˜ธ์˜ ์˜๋ฏธ๋Š” ๋‹ค์Œ๊ณผ ๊ฐ™์Šต๋‹ˆ๋‹ค.

๋Š” ์œ„ํ—˜์ด ๋ฐœ์ƒํ•  ์šฐ๋ ค๊ฐ€ ์žˆ์œผ๋ฏ€๋กœ ์ฃผ์˜ํ•˜๋ผ๋Š” ๊ธฐํ˜ธ์ž…๋‹ˆ๋‹ค.

๋Š” ๊ฐ์ „์˜ ๊ฐ€๋Šฅ์„ฑ์ด ์žˆ์œผ๋ฏ€๋กœ ์ฃผ์˜ํ•˜๋ผ๋Š” ๊ธฐํ˜ธ์ž…๋‹ˆ๋‹ค.

์‚ฌ์šฉ์„ค๋ช…์„œ๋ฅผ ์ฝ๊ณ  ๋‚œ ํ›„ ์‚ฌ์šฉํ•˜๋Š” ์‚ฌ๋žŒ์ด ์–ธ์ œ๋ผ๋„ ๋ณผ ์ˆ˜ ์žˆ๋Š” ์žฅ์†Œ์— ๋ณด๊ด€ ํ•˜

์‹ญ์‹œ์˜ค.

SV-iS7 ์‹œ๋ฆฌ์ฆˆ ์ธ๋ฒ„ํ„ฐ์˜ ๊ธฐ๋Šฅ์„ ์ถฉ๋ถ„ํ•˜๊ณ  ์•ˆ์ „ํ•˜๊ฒŒ ์‚ฌ์šฉํ•˜๊ธฐ ์œ„ํ•˜์—ฌ ์ด ์‚ฌ์šฉ

์„ค๋ช…์„œ๋ฅผ ์ž˜ ์ฝ์–ด ๋ณด์‹ญ์‹œ์˜ค.

์ฃผ ์˜

์˜ต์…˜๋ณด๋“œ์˜ CMOS ์†Œ์ž๋“ค์˜ ์ทจ๊ธ‰์— ์ฃผ์˜ํ•˜์‹ญ์‹œ์˜ค.

์ •์ „๊ธฐ์— ์˜ํ•œ ๊ณ ์žฅ์˜ ์›์ธ์ด ๋ฉ๋‹ˆ๋‹ค.

ํ†ต์‹  ์‹ ํ˜ธ์„  ๋“ฑ์˜ ๋ณ€๊ฒฝ ์ ‘์†์€ ์ธ๋ฒ„ํ„ฐ ์ „์›์„ ๋‚ด๋ฆฐ ์ƒํƒœ์—์„œ ํ•˜์‹ญ์‹œ์˜ค.

ํ†ต์‹ ๋ถˆ๋Ÿ‰ ๋ฐ ๊ณ ์žฅ์˜ ์›์ธ์ด ๋ฉ๋‹ˆ๋‹ค.

์ธ๋ฒ„ํ„ฐ ๋ณธ์ฒด์™€ ์˜ต์…˜๋ณด๋“œ ์ปค๋„ฅํ„ฐ๊ฐ€ ์ •ํ™•ํžˆ ์ผ์น˜ํ•˜๊ฒŒ ์ ‘์†๋˜๋„๋ก ํ•˜์‹ญ์‹œ์˜ค.

์ง€์‹œ์‚ฌํ•ญ์„ ์œ„๋ฐ˜ํ•  ๋•Œ ์‹ฌ๊ฐํ•œ ์ƒํ•ด๋‚˜ ์‚ฌ๋ง์ด ๋ฐœ์ƒํ•  ๊ฐ€๋Šฅ

์„ฑ์ด ์žˆ๋Š” ๊ฒฝ์šฐ

์ง€์‹œ์‚ฌํ•ญ์„ ์œ„๋ฐ˜ํ•  ๋•Œ ๊ฒฝ๋ฏธํ•œ ์ƒํ•ด๋‚˜ ์ œํ’ˆ์†์ƒ์ด ๋ฐœ์ƒํ•  ๊ฐ€๋Šฅ

์„ฑ์ด ์žˆ๋Š” ๊ฒฝ์šฐ

Page 31: iS7 CC-Link User Manual

iS7 CC-Link Manual

2

ํ†ต์‹ ๋ถˆ๋Ÿ‰ ๋ฐ ๊ณ ์žฅ์˜ ์›์ธ์ด ๋ฉ๋‹ˆ๋‹ค.

ํŒŒ๋ผ๋ฏธํ„ฐ๋ฅผ ์„ค์ •ํ•  ๋•Œ๋Š” ํŒŒ๋ผ๋ฏธํ„ฐ Unit์„ ํ™•์ธํ•˜์‹œ๊ธฐ ๋ฐ”๋ž๋‹ˆ๋‹ค.

ํ†ต์‹ ๋ถˆ๋Ÿ‰์˜ ์›์ธ์ด ๋ฉ๋‹ˆ๋‹ค.

Page 32: iS7 CC-Link User Manual

iS7 CC-Link Manual

3

์†Œ๊ฐœ

iS7 CC-Link ํ†ต์‹  ์นด๋“œ๋Š” CC-Link Network์—์„œ CC-Link ๋งˆ์Šคํ„ฐ๊ฐ€ ์ธ๋ฒ„ํ„ฐ๋ฅผ ์šด

์ „, ์ •์ง€์‹œํ‚ค๊ณ  ์ธ๋ฒ„ํ„ฐ์˜ ์ƒํƒœ๋ฅผ ๋ชจ๋‹ˆํ„ฐ๋ง์„ ๊ฐ€๋Šฅํ•˜๊ฒŒ ํ•ด์ฃผ๋Š” ํ†ต์‹  ์นด๋“œ์ž…๋‹ˆ๋‹ค.

iS7 CC-Link๊ฐ€ ์ œ๊ณตํ•˜๋Š” CC-Link์˜ ๋ฒ„์ „์€ 1.10์ž…๋‹ˆ๋‹ค.

1. CC-Link ํ†ต์‹  ์นด๋“œ Technical Data

2. ์ œํ’ˆ ๊ตฌ์„ฑ๋ฌผ

iS7 CC-Link ํ†ต์‹  ์นด๋“œ 1๊ฐœ, ์Šคํฌ๋ฅ˜ 1๊ฐœ, ๋ณธ ์‚ฌ์šฉ์„ค๋ช…์„œ๋กœ ๊ตฌ์„ฑ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.

ํ†ต์‹  ์†๋„ 156k, 625k, 2.5M, 5M, 10Mbps ์ง€์›

Station Type ๋ฆฌ๋ชจํŠธ ๋””๋ฐ”์ด์Šค๊ตญ

์ ์œ ๊ตญ ์ˆ˜ 1๊ตญ ์ ์œ 

Version V1.10

์ ‘์† ๋Œ€์ˆ˜

(1 X a) + (2 X b) + (3 X c) + (4 X d) โ‰ค 64

a : 1๊ตญ ์ ์œ  Unit์˜ ๋Œ€์ˆ˜

b : 2๊ตญ ์ ์œ  Unit์˜ ๋Œ€์ˆ˜

c : 3๊ตญ ์ ์œ  Unit์˜ ๋Œ€์ˆ˜

d : 4๊ตญ ์ ์œ  Unit์˜ ๋Œ€์ˆ˜

16 X A + 54 X B + 88 X C โ‰ค 2304

A : ๋ฆฌ๋ชจํŠธ I/O๊ตญ ๋Œ€์ˆ˜ ------------------------์ตœ๋Œ€ 64๋Œ€

B : ๋ฆฌ๋ชจํŠธ ๋””๋ฐ”์ด์Šค๊ตญ ๋Œ€์ˆ˜ -------------------์ตœ๋Œ€ 42๋Œ€

C : ๋กœ์ปฌ๊ตญ, ์ธํ…”๋ฆฌ์ „ํŠธ ๋””๋ฐ”์ด์Šค๊ตญ ๋Œ€์ˆ˜ ------์ตœ๋Œ€ 26๋Œ€

Interface 5Pin Pluggable connector

Cable CC-Link ์ „์šฉ ์ผ€์ด๋ธ”, CC-Link Ver1.10 ํ˜ธํ™˜ ์ „์šฉ ์ผ€์ด๋ธ”

์™ธ๊ฒฝ(๋ฐ”๊นฅ์ง€๋ฆ„) 8.0 mm์ดํ•˜

Page 33: iS7 CC-Link User Manual

iS7 CC-Link Manual

4

3. iS7 CC-Link ์™ธ๊ด€ ๋ฐ ์„ค์น˜

(1) ์™ธ๊ด€

(2) ๋‚ด๋ถ€

CPU

5Pin Pluggable

ConnectorInverter

Connector

COM

RUN

ERR

CPU

CC-Link

ASIC

์„ค์ •

์Šค์œ„์น˜

Page 34: iS7 CC-Link User Manual

iS7 CC-Link Manual

5

(3) iS7 ์ธ๋ฒ„ํ„ฐ์— ํ†ต์‹  ์นด๋“œ ์ฒด๊ฒฐ

(4) CC-Link ์‹ ํ˜ธ์„  ์—ฐ๊ฒฐ ์ปค๋„ฅํ„ฐ์˜ ๊ตฌ์กฐ ๋ฐ ๊ฒฐ์„ ๋ฐฉ๋ฒ•

โ‘  DA(Blue) โ‘กDB(White) โ‘ขDG(Yellow) โ‘ฃSLD(Shielded twisted Cable) โ‘คFG

<์ปค๋„ฅํ„ฐ๊ตฌ์กฐ> <๊ฒฐ์„ ๋ฐฉ๋ฒ•>

โ€ป iS7 CC-Link ํ†ต์‹  ์นด๋“œ์—์„œ๋Š” OSADA OS-86-5P์„ ์‚ฌ์šฉํ•ฉ๋‹ˆ๋‹ค.(5PIN์ปค๋„ฅํ„ฐ)

โ‘  โ‘ข โ‘ก โ‘ฃ โ‘ค

CC-Link ํ†ต์‹ ์นด๋“œ

Page 35: iS7 CC-Link User Manual

iS7 CC-Link Manual

6

4. Network ์—ฐ๊ฒฐ

ํ†ต์‹ ์„  ์—ฐ๊ฒฐ ์ž

์ข…๋‹จ ์ €ํ•ญ ์„ค์ • ๋ฐฉ๋ฒ•

โ€ป iS7 CC-Link ํ†ต์‹  ์นด๋“œ๊ฐ€ Network์˜ ๋งจ ๋งˆ์ง€๋ง‰์— ์œ„์น˜ํ•˜๊ฒŒ ๋  ๋•Œ ํ†ต์‹  ์นด

๋“œ์˜ ์ €ํ•ญ์˜ ์„ค์ • ์Šค์œ„์น˜๋ฅผ ON ํ•ด์ฃผ์–ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

์ €ํ•ญ์€ 110 ฮฉ 1/2W ์ž…๋‹ˆ๋‹ค.

์ €ํ•ญ ์Šค์œ„์น˜๊ฐ€ ์ €ํ•ญ ์Šค์œ„์น˜๊ฐ€

์™ผ์ชฝ์œผ๋กœ ์œ„์น˜ํ•  ๊ฒฝ์šฐ(OFF) ์˜ค๋ฅธ์ชฝ์œผ๋กœ ์œ„์น˜ํ•  ๊ฒฝ์šฐ(ON)

โ†’ ์ €ํ•ญ ์‚ฌ์šฉ ์•ˆํ•จ โ†’ ์ €ํ•ญ ์‚ฌ์šฉ

No. ์‹ ํ˜ธ ์„ค๋ช… ์„  ์ƒ‰

1 DA Transmit/Receive data Blue

2 DB Transmit/Receive data White

3 DG Signal Ground Yellow

4 SLD Shield Shielded twisted Cable

5 FG Frame Ground

- ํ‘œ๊ธฐ๋œ ํ”Œ๋ผ์Šคํ‹ฑ ๋ฎ๊ฐœ๋ฅผ ์ž˜๋ผ ๋ƒ…๋‹ˆ๋‹ค.

- ์•ˆ์— ์žˆ๋Š” ์Šค์œ„์น˜๋ฅผ ONํ•˜๋ฉด ์ €ํ•ญ์ด

์„ค์ •๋ฉ๋‹ˆ๋‹ค.

์ €ํ•ญ ์Šค์œ„์น˜

Page 36: iS7 CC-Link User Manual

iS7 CC-Link Manual

7

Hardware ์„ค์น˜ ๋ฐฉ๋ฒ•

๊ฒฝ๊ณ ) ์ธ๋ฒ„ํ„ฐ์˜ ์ „์›์„ OFF ํ›„ ํ†ต์‹  ๋„คํŠธ์›Œํฌ๋ฅผ ์—ฐ๊ฒฐ ํ•˜์‹ญ์‹œ์˜ค.

CC-Link ํ†ต์‹  ์ผ€์ด๋ธ” ๋ฐฐ์„ 

์•„๋ž˜์˜ ์ˆœ์„œ์— ๋”ฐ๋ผ CC-Link ์ „์šฉ ํ†ต์‹  ์ผ€์ด๋ธ”์„ ์‚ฌ์šฉํ•ด์„œ ์ž๋Œ€์— ๋ฐฐ์„ ํ•˜

์—ฌ ์ฃผ์‹ญ์‹œ์˜ค.

๋…ธ์ด์ฆˆ๋ฅผ ์ค„์ด๊ธฐ ์œ„ํ•ด์„œ Network ์–‘ ๋์— ์žˆ๋Š” iS7 CC-Link ํ†ต์‹  ์นด๋“œ์—

์ฒ˜๋ฆฌ๋ฅผ ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค. CC-Link ํ†ต์‹  ์นด๋“œ์— ์žˆ๋Š” ์ €ํ•ญ ์Šค์œ„์น˜๋ฅผ ON

ํ•ด์„œ ์ฒ˜๋ฆฌ๋ฅผ ํ•ด ์ค๋‹ˆ๋‹ค.

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

DA

DB

DG

SLD

FG

Blue

White

Yellow

Shielded Twisted Cable

Blue Blue

White White

Yellow Yellow

Shielded Twisted Cable

Shielded Twisted Cable

์Šค์œ„์น˜ ON ์Šค์œ„์น˜ ON

Page 37: iS7 CC-Link User Manual

iS7 CC-Link Manual

8

ํ†ต์‹  ์ผ€์ด๋ธ” ํŠน์„ฑ

ํ†ต์‹  ์ผ€์ด๋ธ”์€ ๋ฐ˜๋“œ์‹œ ๋‹ค์Œ์— ๋ณด์—ฌ์ฃผ๋Š” ๊ถŒ์žฅ ์ผ€์ด๋ธ”์„ ์‚ฌ์šฉํ•˜์—ฌ ์ฃผ์‹ญ์‹œ์˜ค.

๊ถŒ์žฅ ์ผ€์ด๋ธ” ์ด์™ธ์˜ ์ผ€์ด๋ธ” ์‚ฌ์šฉ ์‹œ CC-Link์˜ ์„ฑ๋Šฅ์„ ๋ณด์žฅ ํ•  ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค.

์ฃผ1) PLFEV-AMESB [LS์ „์„  ์ œ์ž‘] ๊ถŒ์žฅํ•จ

์ฃผ2) ํŠน์„ฑ ์ž„ํ”ผ๋˜์Šค ์ธก์ •๋ฐฉ๋ฒ•

์ผ€์ด๋ธ” ๊ธธ์ด : 100m ์ด์ƒ

์ธก์ •๋ฐฉ๋ฒ•์€ ์ง€์ •ํ•˜์ง€ ์•Š์ง€๋งŒ, Open/Short๋ฒ•์˜ ๊ฒฝ์šฐ๋Š” ์‹ค์ธก์น˜๋ฅผ ๊ทผ์‚ฌ๊ฐ’์œผ๋กœ ํ•˜

์—ฌ ๊ฐ๊ฐ์˜ ์ฃผํŒŒ์ˆ˜ ๋ฒ”์œ„ ์ด๋‚ด๋กœ ํ•ด์•ผ ํ•œ๋‹ค.

ํ•ญ๋ชฉ ์‚ฌ์–‘

ํ˜•๋ช… ์‹ค๋“œ๋ถ€์ฐฉ ํŠธ์œ„์ŠคํŠธ ์ผ€์ด๋ธ”์ฃผ1)

์ „์„  ์ฝ”์–ด ์ˆ˜ 3

๋„์ฒด ๋ฉด์  20AWG

๋„์ฒด ์ €ํ•ญ

(20) 37.8ฮฉ / km์ดํ•˜

์ ˆ์—ฐ์ €ํ•ญ 10000Mฮฉ / km์ด์ƒ

๋‚ด์ „์•• DC500 V 1๋ถ„

์ •์ „์šฉ๋Ÿ‰

(1 kHz) 60 nF / km์ดํ•˜

ํŠน์„ฑ ์ธํ”ผ๋˜์Šค

์ฃผ2)

1MHz 110 ยฑ 15ฮฉ

5MHz 110 ยฑ 6ฮฉ

๋ฉด DA

DB

DG

์™ธํ˜• ์น˜์ˆ˜ 7 mm

Page 38: iS7 CC-Link User Manual

iS7 CC-Link Manual

9

์ตœ๋Œ€ ์ „์†ก ๊ฑฐ๋ฆฌ

Master

Slave Slave Slave Slave Slave Slave

CC-Link ํ†ต์‹  ์˜ต์…˜ ์ตœ๋Œ€ ์ „์†ก ์ง€์—ฐ ์‹œ๊ฐ„

PLC(Master)๋กœ๋ถ€ํ„ฐ ์ˆ˜์‹ ๋œ CC-Link ํ†ต์‹  ๋ฐ์ดํ„ฐ๋ฅผ ์˜ต์…˜ ์นด๋“œ ๋‚ด๋ถ€์ ์œผ๋กœ ์—ฐ์‚ฐ ์ฒ˜

๋ฆฌํ•œ ํ›„ PLC๋กœ ์†ก์‹ ํ•˜๊ธฐ๊นŒ์ง€์˜ Profile๋ณ„ ์ตœ๋Œ€ ์ „์†ก ์ง€์—ฐ ์‹œ๊ฐ„์€ ํ•˜๊ธฐ์™€ ๊ฐ™์Šต๋‹ˆ๋‹ค.

ํ•˜๊ธฐ ๋ช…๊ธฐ๋œ ์ตœ๋Œ€ ์ „์†ก ์ง€์—ฐ ์‹œ๊ฐ„ ์ดํ•˜๋กœ PLC(Master)ํ†ต์‹  ์ฃผ๊ธฐ ์„ค์ • ์‹œ ์ •ํ™•ํ•œ

CC-Link ํ†ต์‹  ๋™์ž‘์„ ๋ณด์žฅ ํ•  ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค. PLC(Master) ํ†ต์‹  ์„ค์ • ์‹œ ์ฐธ์กฐ ํ•˜์‹ญ

์‹œ์˜ค.

Mode CC-Link ํ†ต์‹  ์˜ต์…˜ ์ตœ๋Œ€ ์ „์†ก ์ง€์—ฐ ์‹œ๊ฐ„

Profile1 80ms

Profile2 15ms

ํ†ต์‹  ์†๋„ 156kbs 625kbps 2.5Mbps 5Mbps 10Mbps

๊ตญ๊ฐ„ ์ผ€์ด

๋ธ” ๊ธธ์ด 20cm์ด์ƒ

์ตœ๋Œ€ ์ „์†ก

๊ฑฐ๋ฆฌ 1200m 900m 400m 160m 100m

Page 39: iS7 CC-Link User Manual

iS7 CC-Link Manual

10

5. LED ํ‘œ์‹œ

CC-Link ํ†ต์‹  ์นด๋“œ์— ์žˆ๋Š” 3๊ฐœ์˜ ๋…น์ƒ‰ LED์™€ 1๊ฐœ์˜ ๋ถ‰์€ ์ƒ‰ LED๋ฅผ ์ด์šฉํ•ด์„œ ํ˜„

์žฌ CC-Link ํ†ต์‹  ์นด๋“œ ์ƒํƒœ๋ฅผ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค. CC-Link ํ†ต์‹  ์นด๋“œ์— ์•„๋ž˜์˜ ์ˆœ์„œ๋กœ

LED๊ฐ€ ์ •๋ ฌ๋˜์–ด ์žˆ์Šต๋‹ˆ๋‹ค.

LED ์ด๋ฆ„ ์ƒ‰ ๊ธฐ๋Šฅ

COM Green

ON โ€“ ํ†ต์‹  ์†ก/์ˆ˜์‹  ์ค‘.

OFF โ€“ ํ†ต์‹  ์†ก/์ˆ˜์‹  ๋˜์ง€ ์•Š์Œ.

ํ†ต์‹  ์ผ€์ด๋ธ”์ด ์ œ๋Œ€๋กœ ์—ฐ๊ฒฐ ๋˜์—ˆ๋Š”์ง€ ํ™•์ธํ•˜์‹ญ์‹œ

์˜ค.

RUN Green

ON โ€“ Station ID์™€ Baud Rate๊ฐ€ ์ •์ƒ์ ์œผ๋กœ ์„ค์ •์ด ๋˜์–ด

์žˆ๊ณ  Refresh ๋ฐ์ดํ„ฐ๊ฐ€ ์ •์ƒ์ ์œผ๋กœ ์ˆ˜์‹ ๋จ.

OFF โ€“ CC-Link ํ†ต์‹ ์ด ์„ฑ๋ฆฝ ๋˜์ง€ ์•Š์Œ.

COM-09(Station ID)์™€ COM-10(Baud Rrate)์ด

์ œ๋Œ€๋กœ ์„ค์ • ๋˜์—ˆ๋Š”์ง€ ํ™•์ธํ•˜์‹ญ์‹œ์˜ค.

ERR Red ON โ€“ CRC์—๋Ÿฌ

OFF โ€“ ์ •์ƒ.

CPU Green

1์ดˆ ์ฃผ๊ธฐ๋กœ ์ ๋ฉธ โ€“ CC-Link ํ†ต์‹  ์นด๋“œ์— ์ „์›์ด ๊ณต๊ธ‰์ด ๋˜์–ด

์žˆ๊ณ  CC-Link ํ†ต์‹  ์นด๋“œ์˜ ์ƒํƒœ๊ฐ€ ์ •์ƒ์ž„์„ ๋‚˜ํƒ€๋ƒ…๋‹ˆ๋‹ค.

OFF โ€“ CC-Link ํ†ต์‹  ์นด๋“œ๊ฐ€ ์ „์›์ด ๊ณต๊ธ‰ ๋˜์ง€ ์•Š์•˜๊ฑฐ๋‚˜ CC-

Link ํ†ต์‹  ์นด๋“œ ์ž์ฒด ๋ฌธ์ œ๊ฐ€ ์žˆ์„ ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

200mSec ์ฃผ๊ธฐ๋กœ ๋ถˆ ์ ๋ฉธ โ€“ Station ID์™€ Baud Rate ๊ฐ’์ด

๋ณ€๊ฒฝ์ด ๋˜๋ฉด CPU์˜ ๋‚ด๋ถ€ ๋ฉ”๋ชจ๋ฆฌ์— ์ €์žฅ ๋˜๋Š”๋ฐ ๋‚ด๋ถ€ ๋ฉ”๋ชจ๋ฆฌ

์ €์žฅ ์‹คํŒจ ์‹œ ์—๋Ÿฌ๋ฅผ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค.

2์ดˆ ์ฃผ๊ธฐ๋กœ ๋ถˆ ์ ๋ฉธ โ€“ CC-Link ํ†ต์‹  ์นด๋“œ์™€ ์ธ๋ฒ„ํ„ฐ ์‚ฌ์ด์—

Interface ํ†ต์‹ ์— ์ด์ƒ์ด ์žˆ์Œ์„ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค.

Green

RUN

Red

ERR

Green

COM

Green

CPU

Page 40: iS7 CC-Link User Manual

iS7 CC-Link Manual

11

6. Trouble Shooting

LED ํ‘œ์‹œ ์›์ธ ๋Œ€์ฑ…

COM RUN ERR CPU

OFF OFF OFF OFF

ํ†ต์‹ ์นด๋“œ์— ์ „์›์ด

๊ณต๊ธ‰์ด ๋˜๊ณ  ์žˆ์ง€

์•Š์Œ.

ํ†ต์‹  ์นด๋“œ๊ฐ€ ์ธ๋ฒ„ํ„ฐ์— ์ œ๋Œ€๋กœ

์žฅ์ฐฉ์ด ๋˜์—ˆ๋Š”์ง€ ํ™•์ธํ•œ๋‹ค.

์ธ๋ฒ„ํ„ฐ ์ „์›์„ ON ํ–ˆ๋Š”์ง€

ํ™•์ธํ•œ๋‹ค.

๋ฌด๊ด€ ๋ฌด๊ด€ ๋ฌด๊ด€

200m

์ฃผ๊ธฐ

์ ๋ฉธ

๋‚ด๋ถ€๋ฉ”๋ชจ๋ฆฌ์ €์žฅ

์ด์ƒ

ํ†ต์‹ ์„ ๊ณผ ์ธ๋ฒ„ํ„ฐ Power ์„ ์ด

๋ถ„๋ฆฌ ๋˜์–ด ์žˆ๋Š”์ง€ ํ™•์ธ ํ•ฉ๋‹ˆ๋‹ค.

์ธ๋ฒ„ํ„ฐ ์ „์›์„ OFF ํ›„ ๋‹ค์‹œ ON

ํ•ฉ๋‹ˆ๋‹ค.

๋ฌด๊ด€ ๋ฌด๊ด€ ๋ฌด๊ด€ 2์ดˆ์ฃผ๊ธฐ

์ ๋ฉธ

ํ†ต์‹ ์นด๋“œ์™€ ์ธ๋ฒ„ํ„ฐ

Interfaceํ†ต์‹ ์ด์ƒ.

ํ†ต์‹ ์„ ๊ณผ ์ธ๋ฒ„ํ„ฐ Power ์„ ์ด

๋ถ„๋ฆฌ ๋˜์–ด ์žˆ๋Š”์ง€ ํ™•์ธ ํ•ฉ๋‹ˆ๋‹ค.

์ธ๋ฒ„ํ„ฐ ์ „์›์„ OFF ํ›„ ๋‹ค์‹œ ON

ํ•ฉ๋‹ˆ๋‹ค.

OFF OFF ๋ฌด๊ด€ 1์ดˆ์ฃผ๊ธฐ

์ ๋ฉธ

ํ†ต์‹ ์ด ๋˜๊ณ  ์žˆ์ง€

์•Š์Œ.

ํ†ต์‹  ์ผ€์ด๋ธ”์ด ์ œ๋Œ€๋กœ ์—ฐ๊ฒฐ๋˜์–ด

์žˆ๋Š”์ง€ ํ™•์ธ ํ•ฉ๋‹ˆ๋‹ค.

๋ฌด๊ด€ OFF ๋ฌด๊ด€ 1์ดˆ์ฃผ๊ธฐ

์ ๋ฉธ

StationID์™€

Baudrate๊ฐ’์ด

์ •ํ™•์ง€ ์•Š์Œ.

Station ID์™€ Baudrate๋ฅผ

์˜ฌ๋ฐ”๋ฅด๊ฒŒ ์„ค์ •ํ•œ ํ›„ Comm

Update๋ฅผ ํ•ฉ๋‹ˆ๋‹ค.

๋ฌด๊ด€ ON ์ ๋ฉธ 1์ดˆ์ฃผ๊ธฐ

์ ๋ฉธ

ํ†ต์‹ ์นด๋“œ์— ์ „์›์ด

ON๋œ์ดํ›„ Station

ID์™€ Baudrate๊ฐ€

๋ณ€๊ฒฝ๋จ.

Baudrate์™€ Station ID๋ฅผ

์ด์ „์— ์„ค์ •ํ•œ ๊ฐ’์œผ๋กœ ๋ณ€๊ฒฝํ•˜๊ฑฐ๋‚˜

๋ณ€๊ฒฝ๋œ Baudrate์™€ Station

ID๊ฐ’์„ ํ†ต์‹  ์นด๋“œ์— ๋ฐ˜์˜์ด ๋˜๊ฒŒ

ํ•˜๋ ค๋ฉด Comm Update๋ฅผ ํ•ฉ๋‹ˆ๋‹ค.

ON ON ์ ๋ฉธ 1์ดˆ์ฃผ๊ธฐ

์ ๋ฉธ

CRC ์—๋Ÿฌ ๋ฐœ์ƒ. ๋…ธ์ด์ฆˆ์˜ ์˜ํ–ฅ์œผ๋กœ CRC ์—๋Ÿฌ๊ฐ€

๋ฐœ์ƒํ•œ ์ƒํ™ฉ์ž…๋‹ˆ๋‹ค. ํ†ต์‹ ์„ ๊ณผ

์ธ๋ฒ„ํ„ฐ Power ์„ ์ด ๋ถ„๋ฆฌ ๋˜์–ด

์žˆ๋Š”์ง€ ํ™•์ธ ํ•ฉ๋‹ˆ๋‹ค.

Page 41: iS7 CC-Link User Manual

iS7 CC-Link Manual

12

7. Quick Communication Start ์ธ๋ฒ„ํ„ฐ ์ „์›์ด Off์ธ ์ƒํƒœ์—์„œ CC-Link ํ†ต์‹  ์นด๋“œ๋ฅผ ์žฅ์ฐฉํ•œ ํ›„ ์ธ๋ฒ„ํ„ฐ ์ „์›์„

On ํ•œ ํ›„ CNF-30 ํŒŒ๋ผ๋ฏธํ„ฐ๊ฐ€ โ€œCC-Linkโ€์ธ์ง€ ํ™•์ธ์„ ํ•ฉ๋‹ˆ๋‹ค.

(1) CC-Link ํ†ต์‹  ์นด๋“œ์— ํ†ต์‹  Cable์„ ์—ฐ๊ฒฐํ•ด์„œ Network์— ์ ‘์†ํ•ฉ๋‹ˆ๋‹ค.

(2) COM-7 FBus ID ํŒŒ๋ผ๋ฏธํ„ฐ์—์„œ ์ธ๋ฒ„ํ„ฐ์˜ Station ID๋ฅผ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค.

(3) COM-10 Opt Parameter1 ํŒŒ๋ผ๋ฏธํ„ฐ์—์„œ Baud Rate๋ฅผ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค.

(4) COM-94 Comm Update Yes๋ฅผ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค.

(5) CC-Link ํ†ต์‹  ์นด๋“œ์˜ RUN LED์— ๋ถˆ์ด ์ผœ์ง€๋Š”์ง€ ํ™•์ธ ํ•ฉ๋‹ˆ๋‹ค.

CC Link์˜ RUN LED์— ๋ถˆ์ด ์ผœ์ง€์ง€ ์•Š์œผ๋ฉด COM-7, COM-10์˜ Keypad

ํŒŒ๋ผ๋ฏธํ„ฐ ์„ค์ • ๊ฐ’์ด ์ •ํ™•ํ•œ์ง€ ๋‹ค์‹œ ํ™•์ธ ํ•˜์‹ญ์‹œ์˜ค.

Page 42: iS7 CC-Link User Manual

iS7 CC-Link Manual

13

8. CC-Link ๊ด€๋ จ Keypad ํŒŒ๋ผ๋ฏธํ„ฐ

Code ํŒŒ๋ผ๋ฏธํ„ฐ ์ด๋ฆ„ ์ดˆ๊ธฐ๊ฐ’ Range

CNF-30 Option-1 Type - -

DRV-06 Cmd Source Fx/Rx-1 Keypad

Fx/Rx-1

Fx/Rx-2

Int. 485

FieldBus

PLC

DRV-07 Freq Ref Src Keypad-1 Keypad-1

Keypad-2

V1

I1

V2

I2

Int. 485

Encoder

FieldBus

PLC

PRT-12 Lost Cmd Mode None None

FreeRun

Dec

Hold Input

Hold Output

Lost Preset

PRT-13 Lost Cmd Time 1.0sec 0.1~120.0sec

PRT-14 Lost Preset F 0.00Hz 0.00~400.00Hz

COM-06 FBus S/W Ver - -

COM-07 FBus ID 1 0~64

COM-09 FBus LED - -

Page 43: iS7 CC-Link User Manual

iS7 CC-Link Manual

14

(1) Option-1 Type (CNF-30) โ€“ ์ธ๋ฒ„ํ„ฐ์— ์žฅ์ฐฉ๋œ ํ†ต์‹  ์นด๋“œ ์ด๋ฆ„ ํ‘œ์‹œ

์ธ๋ฒ„ํ„ฐ์— ์žฅ์ฐฉ๋œ ํ†ต์‹  ์นด๋“œ ์ด๋ฆ„์„ ํ‘œ์‹œ ํ•ฉ๋‹ˆ๋‹ค.

CC-Link ํ†ต์‹  ์นด๋“œ๊ฐ€ ์ œ๋Œ€๋กœ ์žฅ์ฐฉ์ด ๋˜๊ณ  CC-Link ํ†ต์‹  ์นด๋“œ์— ๋ฌธ์ œ๊ฐ€

์—†์œผ๋ฉด โ€œCC-Linkโ€ ๋ผ๊ณ  ํ‘œ์‹œ ๋ฉ๋‹ˆ๋‹ค

(2) Cmd Source (DRV-06) โ€“ ์ธ๋ฒ„ํ„ฐ ์šด์ „ ์ง€๋ น ์†Œ์Šค ์„ค์ •

์ธ๋ฒ„ํ„ฐ์˜ ์šด์ „ ์ง€๋ น ์†Œ์Šค๋ฅผ ์„ค์ • ํ•ฉ๋‹ˆ๋‹ค.

CC-Link ํ†ต์‹ ์œผ๋กœ ์ธ๋ฒ„ํ„ฐ๋ฅผ ์šด์ „/์ •์ง€ ์ง€๋ น์„ ํ•˜๊ณ ์ž ํ•  ๊ฒฝ์šฐ โ€œFieldbusโ€

๋กœ ์„ค์ • ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

(3) Freq Ref Src (DRV-07) โ€“ ์ธ๋ฒ„ํ„ฐ ์ฃผํŒŒ์ˆ˜ ์ง€๋ น ์†Œ์Šค ์„ค์ •

์ธ๋ฒ„ํ„ฐ์˜ ์ฃผํŒŒ์ˆ˜ ์ง€๋ น ์†Œ์Šค๋ฅผ ์„ค์ • ํ•ฉ๋‹ˆ๋‹ค.

CC-Link ํ†ต์‹ ์œผ๋กœ ์ธ๋ฒ„ํ„ฐ์˜ ์ง€๋ น ์ฃผํŒŒ์ˆ˜๋ฅผ ์„ค์ •ํ•˜๊ณ  ์‹ถ์€ ๊ฒฝ์šฐ โ€œFieldbus

๋กœ ์„ค์ • ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

(4) Lost Cmd Mode (PRT-12) โ€“ ํ†ต์‹œ ์ง€๋ น ์ƒ์‹ค ์‹œ ์šด์ „ ๋ฐฉ๋ฒ•

PRT-12 Lost Cmd Mode๋Š” PRT-13 Lost Cmd Time ์‹œ๊ฐ„ ๋™์•ˆ ํ†ต์‹  ์ง€๋ น

์ƒ์‹ค์ด ๋ฐœ์ƒํ•ด์„œ ํ†ต์‹  ์ง€๋ น ์ƒ์‹ค๋กœ ์ธ์‹ ํ–ˆ์„ ๋•Œ ์šด์ „ ๋ฐฉ๋ฒ•์„ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค.

๋ฉ๋‹ˆ๋‹ค.

None : Inverter๊ฐ€ Lost Command ์ƒํƒœ๊ฐ€ ๋˜์–ด๋„ ์•„๋ฌด๋Ÿฐ ์กฐ์น˜๋ฅผ ํ•˜์ง€ ์•Š์Œ

COM-10 Opt Parameter1 0 0 (156k)

1 (625k)

2 (2.5M)

3 (5M)

4 (10M)

COM-11 Opt Parameter2 0 0 (Profile1)

1 (Profile2)

COM-31

~COM-38

Para Status-1

~ Para Status-8

- 0x0000

~0xFFFF

COM-51

~COM-58

Para Control-1

~ Para Control-8

- 0x0000

~0xFFFF

COM-94 Comm Update No No

Yes

Page 44: iS7 CC-Link User Manual

iS7 CC-Link Manual

15

FreeRun : Lost Command ์ƒํƒœ๊ฐ€ ๋˜๋ฉด FreeRun์ •์ง€๋ฅผ ํ•˜๊ฒŒ ๋˜๊ณ  Trip ๋ฐœ์ƒ

Dec : Lost Command ์ƒํƒœ๊ฐ€ ๋˜๋ฉด ๋ชจํ„ฐ๋Š” ๊ฐ์† ์ •์ง€๋ฅผ ํ•˜๊ฒŒ ๋˜๊ณ  Lost Command Trip ๋ฐœ์ƒ

Hold Input : ๋งˆ์ง€๋ง‰์œผ๋กœ ๋“ค์–ด์˜จ ์†๋„์ง€๋ น์œผ๋กœ ์šด์ „ํ•˜๋ฉด์„œ Lost Command Warning ๋ฐœ์ƒ

Hold Ouput : ํ˜„์žฌ ์šด์ „ ์†๋„๋กœ ๋ชจํ„ฐ๋Š” ์šด์ „ํ•˜๋ฉด์„œ Lost Command Warning ๋ฐœ์ƒ

Lost Preset : PRT-14์— ์„ค์ •ํ•œ ์šด์ „ ์†๋„๋กœ ์šด์ „ํ•˜๋ฉด์„œ Lost Command Warning ๋ฐœ์ƒ

(5) Lost Preset F (PRT-14) โ€“ Lost Preset ์„ค์ • ์ฃผํŒŒ์ˆ˜

PRT-12 Lost Cmd Mode๋ฅผ Lost Preset์œผ๋กœ ์„ค์ • ํ•œ ๊ฒฝ์šฐ ํ†ต์‹  ์ง€๋ น ์ƒ์‹ค

๋ฐœ์ƒ ์‹œ Lost Preset F๋กœ ์„ค์ •ํ•œ ์ฃผํŒŒ์ˆ˜๋กœ ์šด์ „ํ•˜๊ฒŒ ๋ฉ๋‹ˆ๋‹ค.

(6) Lost Cmd Time (PRT-13) โ€“ ํ†ต์‹œ ์ง€๋ น ์ƒ์‹ค ํŒ์ • ์‹œ๊ฐ„

PRT-13 Lost Cmd Time์— ์„ค์ •๋œ ์‹œ๊ฐ„ ๋™์•ˆ ๊ณ„์† ํ†ต์‹  ์ง€๋ น ์ƒ์‹ค์ด ๋ฐœ์ƒ

์„ ํ•˜๋ฉด ํ†ต์‹  ์ง€๋ น ์ƒ์‹ค๋กœ ์ธ์‹์„ ํ•ฉ๋‹ˆ๋‹ค.

PRT-13 Lost Cmd Time ์‹œ๊ฐ„ ์ด๋‚ด์— ํ†ต์‹ ์ด ๋‹ค์‹œ ์žฌ๊ฐœ๊ฐ€ ๋˜์–ด ์ •์ƒ ์ƒํƒœ

๋กœ ๋ณต๊ตฌ๊ฐ€ ๋˜๋ฉด ์—๋Ÿฌ๋กœ ์ธ์‹์„ ํ•˜์ง€ ์•Š์Šต๋‹ˆ๋‹ค.

(7) FBus S/W Ver (COM-06) โ€“ ์ธ๋ฒ„ํ„ฐ์— ์žฅ์ฐฉ๋œ ํ†ต์‹  ์นด๋“œ ๋ฒ„์ „ ํ‘œ์‹œ

์ธ๋ฒ„ํ„ฐ์— ์žฅ์ฐฉ๋œ ํ†ต์‹  ์นด๋“œ์˜ ๋ฒ„์ „์„ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค.

(8) FBus ID (COM-07) โ€“ Station Number ์„ค์ •

CC-Link์˜ Station ID๊ฐ’์„ ์„ค์ •ํ•˜๋Š” ํŒŒ๋ผ๋ฏธํ„ฐ ์ž…๋‹ˆ๋‹ค. Station Number๋Š”

0~64๊นŒ์ง€ ์„ค์ • ๊ฐ€๋Šฅ ํ•ฉ๋‹ˆ๋‹ค.

Station ID๋Š” ์ค‘๋ณต ์„ค์ • ํ•  ์ˆ˜ ์—†์Šต๋‹ˆ๋‹ค. ์„ค์ •ํ•˜๋Š” Station ID๊ฐ’์ด ๋‹ค๋ฅธ

Station ID๋กœ ์„ค์ • ๋˜์–ด ์žˆ์ง€ ์•Š์€์ง€ ํ™•์ธํ•˜์—ฌ ์ฃผ์‹ญ์‹œ์˜ค.

์ง€๋ น

์ƒ์‹ค

์ง€๋ น

์ƒ์‹ค

PRT-13

Lost Cmd Time

PRT-13

Lost Cmd Time

์ง€๋ น ์ƒ์‹ค ์ธ์‹

ํ†ต์‹  ๋ผ์ธ ์ƒํƒœ

Page 45: iS7 CC-Link User Manual

iS7 CC-Link Manual

16

Station Number๋ฅผ ๋ณ€๊ฒฝํ•˜๊ณ  ๋ฐ˜๋“œ์‹œ Comm Update๋ฅผ Yes๋กœ ์„ค์ •ํ•ด์•ผ ๋ณ€

๊ฒฝ๋œ Station ID ๊ฐ’์ด CC-Link ํ†ต์‹  ์นด๋“œ์— ๋ฐ˜์˜์ด ๋ฉ๋‹ˆ๋‹ค.

์ฃผ์˜ ์‚ฌํ•ญ

Network ์—ฐ๊ฒฐ ์˜ˆ)

ํ•œ Network์—์„œ Station Number๋ฅผ ์ค‘๋ณต๋˜๊ฒŒ ์„ค์ • ํ•˜์‹œ ๋งˆ์‹ญ์‹œ์˜ค.

Network์—์„œ Station Number ์„ค์ • ์‹œ Station Number๊ฐ€ ์—ฐ์† ๋˜๋„๋ก

์„ค์ •ํ•˜์‹ญ์‹œ์˜ค. (์˜ˆ) Station์ด 3๊ฐœ์ธ ๊ฒฝ์šฐ Station 1, station 2, station 4์™€

๊ฐ™์ด ์„ค์ •ํ•˜์ง€ ๋งˆ์‹ญ์‹œ์˜ค.

(9) FBus LED (COM-09) โ€“ ํ†ต์‹  ์นด๋“œ LED์˜ ON, OFFํ‘œ์‹œ

CC-Link ํ†ต์‹  ์นด๋“œ์˜ ์ƒํƒœ ์ •๋ณด๋ฅผ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค.

Keypad๋กœ COM-9 FBus LED๋ฅผ ๋ณด๋ฉด 4๊ฐœ์˜ LED๊ฐ€ ๋ณด์ž…๋‹ˆ๋‹ค. 4๊ฐœ ์ค‘ 3๊ฐœ์˜

LED๊ฐ€ CC-Link ํ†ต์‹  ์นด๋“œ์˜ ์ƒํƒœ ์ •๋ณด๋ฅผ ํ‘œ์‹œํ•ฉ๋‹ˆ๋‹ค. COM-09์˜ LED ์ˆœ์„œ

์— ๋”ฐ๋ผ (์˜ค๋ฅธ์ชฝ -> ์™ผ์ชฝ) CPU, Inverter Interface ํ†ต์‹  ๋‘์ ˆ, EEPROM์—

Station ID, Baud Rate ์ €์žฅ ์‹คํŒจ ์ •๋ณด๋ฅผ ํ‘œ์‹œ ํ•ด ์ค๋‹ˆ๋‹ค.

COM-09 LED ์ƒํƒœ ์˜ˆ)

๋น„ํŠธ ๋‚ด์šฉ ์ƒํƒœ

0

1

2

3

CPU LED

ERR LED

RUN LED

COM LED

์ •์ƒ์ ์ผ ๋•Œ ์ ๋ฉธ

์—๋Ÿฌ ๋ฐœ์ƒ ์‹œ ON ํ˜น์€ ์ ๋ฉธ

ํ†ต์‹ ์ด ์„ฑ๋ฆฝ ๋˜๋ฉด ON

์†ก ์ˆ˜์‹  ์‹œ ON

Station1 Station2 Station3 Station4

CC-Link Master FBus ID 1 FBus ID 2 FBus ID 3 FBus ID 4

Station0

Page 46: iS7 CC-Link User Manual

iS7 CC-Link Manual

17

(10) Opt Parameter1 (COM-10) โ€“ Baud Rate ์„ค์ •

CC-Link์˜ ํ†ต์‹  ์†๋„๋ฅผ ์„ค์ •ํ•˜๋Š” ํŒŒ๋ผ๋ฏธํ„ฐ ์ž…๋‹ˆ๋‹ค. Baud Rate๋Š”

0(156Kbps)~4(10Mbps)๊นŒ์ง€ ์„ค์ • ๊ฐ€๋Šฅ ํ•ฉ๋‹ˆ๋‹ค.

Baud Rate๋ฅผ ๋ณ€๊ฒฝํ•˜๊ณ  ๋ฐ˜๋“œ์‹œ Comm Update๋ฅผ Yes๋กœ ์„ค์ •ํ•ด์•ผ ๋ณ€๊ฒฝ๋œ

ํ†ต์‹  ์†๋„ ๊ฐ’์ด CC-Link ํ†ต์‹  ์นด๋“œ์— ๋ฐ˜์˜์ด ๋ฉ๋‹ˆ๋‹ค.

(11) Opt Parameter2 (COM-11) โ€“ Profile ์„ค์ •

LS์‚ฐ์ „์—์„œ๋Š” 2๊ฐœ์˜ Profile์„ ์ œ๊ณตํ•ฉ๋‹ˆ๋‹ค.

Profile2๋กœ ์„ค์ • ์‹œ Profile1๋ณด๋‹ค ๋†’์€ ์‘๋‹ต์„ฑ์„ ์ œ๊ณต ํ•ด ์ค๋‹ˆ๋‹ค.

(12) Para Status-1~8 (COM-31~38)

COM-11 Opt Parameter2์˜ ์„ค์ •๊ฐ’์ด 0(Profile1) ์ผ ๋•Œ๋งŒ ๋ณด์ž…๋‹ˆ๋‹ค.

Para Status-1~8์€ ๋ฆฌ๋ชจํŠธ ๋ ˆ์ง€์Šคํ„ฐ์˜ ๋ช…๋ น ์ฝ”๋“œ(RWw2)์˜ Read ์ˆ˜ํ–‰ ์‹œ

Read๋ฅผ ํ•  ์ธ๋ฒ„ํ„ฐ ์ฃผ์†Œ๋ฅผ ์„ค์ •ํ•˜๋Š” ํŒŒ๋ผ๋ฏธํ„ฐ์ž…๋‹ˆ๋‹ค.

๋ช…๋ น ์ฝ”๋“œ RWw2๋กœ ์‚ฌ์šฉํ•ด์„œ Para Status1~8์„ ์ฝ์–ด ์˜ค๋Š” ๋ฐฉ๋ฒ•์„ ์„ค๋ช…ํ•ฉ

๋‹ˆ๋‹ค.

์•„๋ž˜์˜ ๊ทธ๋ฆผ์ด ๋ช…๋ น ์ฝ”๋“œ RWw2์˜ ๊ฐ’ ์ž…๋ ฅ์„ ๊ทธ๋ฆผ์œผ๋กœ ๋‚˜ํƒ€๋‚ธ ๊ทธ๋ฆผ์ธ๋ฐ

Status๋ฅผ Accessํ•˜๊ธฐ ์œ„ํ•ด์„œ Nibble 3, Nibble 2, Nibble1 ์€ ๋ฐ˜๋“œ์‹œ 0 ์ด

์–ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

Nibble0์€ Para Status-1~8 ์ค‘ ์–ด๋Š Status ๊ฐ’์„ ์ฝ์–ด ์˜ฌ์ง€ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค. ,

Nibble0์˜ ๊ฐ’์ด 0์ด๋ฉด Para Status-1์— ํ•ด๋‹น์„ ํ•˜๊ณ  Nibble0์˜ ๊ฐ’์ด 1์ด๋ฉด

Para Status-2์— ํ•ด๋‹นํ•ฉ๋‹ˆ๋‹ค.

์˜ˆ๋ฅผ ๋“ค์–ด RWw2๋ฅผ 0x0003๋กœ ์„ค์ •์ด ๋˜์—ˆ๋‹ค๋ฉด Para Status-4์— ์„ค์ •๋œ

COM LED RUN LED ERR LED CPU LED

OFF OFF ON OFF

Page 47: iS7 CC-Link User Manual

iS7 CC-Link Manual

18

์ธ๋ฒ„ํ„ฐ์˜ ์ฃผ์†Œ์— ์ €์žฅ๋œ ๊ฐ’์„ ์ฝ์–ด์˜ค๊ฒŒ ๋ฉ๋‹ˆ๋‹ค.

3 2 1 0 (Nibble, 4Bit)

0 : Read1 : Write

0

0~7 (Status/Control Number)

< RWw2 >

0

(13) Para Control1~8 (COM-51~58)

COM-11 Opt Parameter2์˜ ์„ค์ •๊ฐ’์ด 0(Profile1) ์ผ ๋•Œ๋งŒ ๋ณด์ž…๋‹ˆ๋‹ค.

Para Control-1~8์€ ๋ฆฌ๋ชจํŠธ ๋ ˆ์ง€์Šคํ„ฐ์˜ ๋ช…๋ น ์ฝ”๋“œ(RWw2)์˜ Write ์ˆ˜ํ–‰

์‹œ Write๋ฅผ ํ•  ์ธ๋ฒ„ํ„ฐ ์ฃผ์†Œ๋ฅผ ์„ค์ •ํ•˜๋Š” ํŒŒ๋ผ๋ฏธํ„ฐ์ž…๋‹ˆ๋‹ค.

๋ช…๋ น ์ฝ”๋“œ RWw2๋กœ ์‚ฌ์šฉํ•ด์„œ Para Control1~8์„ Write ํ•˜๋Š” ๋ฐฉ๋ฒ•์„ ์„ค๋ช…

ํ•ฉ๋‹ˆ๋‹ค..

Control๋ฅผ Writeํ•˜๊ธฐ ์œ„ํ•ด์„œ Nibble 3์€ ๋ฐ˜๋“œ์‹œ 1(Write) ์ด์–ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

Nibble 2, Nibble1์€ ๋ฐ˜๋“œ์‹œ 0 ์ด์–ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

Nibble0์€ Para Control-1~8 ์ค‘ ์–ด๋Š Control ๊ฐ’์„ Write ํ• ์ง€ ์„ค์ •ํ•ฉ๋‹ˆ

๋‹ค. Nibble0์˜ ๊ฐ’์ด 0์ด๋ฉด Para Control-1์— ํ•ด๋‹น์„ ํ•˜๊ณ  Nibble0์˜ ๊ฐ’์ด

1์ด๋ฉด Para Control-2์— ํ•ด๋‹นํ•ฉ๋‹ˆ๋‹ค.

์˜ˆ๋ฅผ ๋“ค์–ด RWw2๋ฅผ 0x1004๋กœ ์„ค์ •์ด ๋˜์—ˆ๋‹ค๋ฉด Para Control-5์— ์„ค์ •๋œ

์ธ๋ฒ„ํ„ฐ์˜ ์ฃผ์†Œ์— RWw3์˜ ๊ฐ’์„ Write ํ•˜๊ฒŒ ๋ฉ๋‹ˆ๋‹ค.

Page 48: iS7 CC-Link User Manual

iS7 CC-Link Manual

19

(14) Comm Update (COM-94)

COM-07 FBus ID์™€ COM-10 Opt Parameter1 ๊ฐ’์„ ๋ณ€๊ฒฝํ•˜๊ณ  ๋ฐ˜๋“œ์‹œ

Comm Update๋ฅผ Yes๋กœ ์„ค์ •ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

Comm Update๋ฅผ ํ•ด์•ผ ๋ณ€๊ฒฝ๋œ Station ID์™€ ํ†ต์‹  ์†๋„๊ฐ€ CC-Link ํ†ต์‹  ์นด

๋“œ์— ๋ฐ˜์˜์ด ๋ฉ๋‹ˆ๋‹ค.

9. CC-Link ๋ฐ์ดํ„ฐ ์ผ๋žŒ

์ธ๋ฒ„ํ„ฐ๋Š” ๋งˆ์Šคํ„ฐ์˜ ๋ฒ„ํผ ๋ฉ”๋ชจ๋ฆฌ 1๊ตญ์ ์„ ์ ์œ ํ•ฉ๋‹ˆ๋‹ค.

์—ฌ๊ธฐ์„œ๋Š” ๋งˆ์Šคํ„ฐ์™€ ์ธ๋ฒ„ํ„ฐ์˜ ์ž…์ถœ๋ ฅ ๋ฐ์ดํ„ฐ ์ •๋ณด๋ฅผ ๋‚˜ํƒ€๋ƒ…๋‹ˆ๋‹ค.

9.1 ๋ฆฌ๋ชจํŠธ I/O

๋ฆฌ๋ชจํŠธ ์ถœ๋ ฅ

๋งˆ์Šคํ„ฐ -> ์ธ๋ฒ„ํ„ฐ

๋ฆฌ๋ชจํŠธ ์ž…๋ ฅ

์ธ๋ฒ„ํ„ฐ -> ๋งˆ์Šคํ„ฐ

๋””๋ฐ”์ด์Šค

No ์‹ ํ˜ธ ๋ช…์นญ

๋””๋ฐ”์ด์Šค

No ์‹ ํ˜ธ ๋ช…์นญ

RY0 ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ง€๋ น RX0 ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ค‘

RY1 ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ง€๋ น RX1 ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ค‘

RY2~8 ๋ฏธ์‚ฌ์šฉ

RX2 ๊ฐ€์† ์ค‘

RX3 ๊ฐ์† ์ค‘

RX4 ์†๋„ ๋„๋‹ฌ

RX5 DC Braking ์ค‘

RX6 ๋ฏธ์‚ฌ์šฉ

RX7 Relay1 ์ถœ๋ ฅ ์ž

RX8 Relay2 ์ถœ๋ ฅ ์ž

RY9 ์ธ๋ฒ„ํ„ฐ ์ถœ๋ ฅ ์ฐจ RX9 Q1 ์ถœ๋ ฅ ์ž

RYA~B ๋ฏธ์‚ฌ์šฉ RXA ๋ฏธ์‚ฌ์šฉ

RXB ๋ฏธ์‚ฌ์šฉ

RYC ๋ชจ๋‹ˆํ„ฐ ์ง€๋ น RXC ๋ชจ๋‹ˆํ„ฐ ์ค‘

RYD ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น1

(RAM) RXD

์ฃผํŒŒ์ˆ˜ ์„ค์ • ์™„๋ฃŒ1

(RAM)

RYE ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น2

(EEPROM) RXE ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์™„๋ฃŒ2

RYF ๋ช…๋ น์ฝ”๋“œ ์‹คํ–‰ ์š”๊ตฌ RXF ๋ช…๋ น ์ฝ”๋“œ ์‹คํ–‰ ์™„๋ฃŒ

Page 49: iS7 CC-Link User Manual

iS7 CC-Link Manual

20

(EEPROM)

RY10~19 ๋ฏธ์‚ฌ์šฉ RX10~19 ๋ฏธ์‚ฌ์šฉ

RY1A ์—๋Ÿฌ Reset RX1A Trip ์ƒํƒœ

RY1B ๋ฏธ์‚ฌ์šฉ RX1B ์šด์ „ ๊ฐ€๋Šฅ ์ƒํƒœ

RY1C~1F ์‹œ์Šคํ…œ ์˜ˆ์•ฝ RX1C~1F ์‹œ์Šคํ…œ ์˜ˆ์•ฝ

9.2 ๋ฆฌ๋ชจํŠธ ์ถœ๋ ฅ

๋ฆฌ๋ชจํŠธ ์ถœ๋ ฅ(Master -> ์ธ๋ฒ„ํ„ฐ)

๋””๋ฐ”์ด

์Šค No ์‹ ํ˜ธ ๋ช…์นญ ๋‚ด ์šฉ

RY0 ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ง€๋ น ON ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ง€๋ น

OFF ์ •์ง€ ์ง€๋ น

RY1 ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ค‘ ON ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ง€๋ น

OFF ์ •์ง€ ์ง€๋ น

RY2~

8

๋ฏธ์‚ฌ์šฉ

RY9 ์ธ๋ฒ„ํ„ฐ ์ถœ๋ ฅ ์ฐจ ON ์ผ ๋•Œ ๋ชจํ„ฐ๋ฅผ FreeRun ์ •์ง€ ํ•ฉ๋‹ˆ๋‹ค.

RYA~

B ๋ฏธ์‚ฌ์šฉ

RYC ๋ชจ๋‹ˆํ„ฐ ์ง€๋ น

ON ์ผ ๋•Œ ๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ(RWw1)์— ํ•ด๋‹นํ•˜๋Š” ๋ชจ

๋‹ˆํ„ฐ ๋ฐ์ดํ„ฐ ๊ฐ’์ด RWr1์— ์ €์žฅ๋ฉ๋‹ˆ๋‹ค. RXC(๋ชจ

๋‹ˆํ„ฐ ์ค‘)๊ฐ€ ON๋ฉ๋‹ˆ๋‹ค.

RYD ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น1

(RAM)

์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น1(RYD)์„ ON์œผ๋กœ ์„ค์ •ํ•˜๋ฉด

์ง€๋ น ์ฃผํŒŒ์ˆ˜(RWw1)๊ฐ€ ์ธ๋ฒ„ํ„ฐ๋กœ ์ž…๋ ฅ์ด ๋ฉ๋‹ˆ

๋‹ค. ์ง€๋ น ์ฃผํŒŒ์ˆ˜๊ฐ€ ์ธ๋ฒ„ํ„ฐ์— ๋ฐ˜์˜์ด ๋˜๋ฉด ์ฃผํŒŒ

์ˆ˜ ์„ค์ • ์™„๋ฃŒ1(RXD)์ด ON๋ฉ๋‹ˆ๋‹ค.

RYE ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น2

(RAM, EEPROM)

์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น2(RYE)๋ฅผ ON์œผ๋กœ ์„ค์ • ํ•˜๋ฉด

์ง€๋ น ์ฃผํŒŒ์ˆ˜(RWw1)๊ฐ€ ์ธ๋ฒ„ํ„ฐ๋กœ ์ž…๋ ฅ์ด ๋ฉ๋‹ˆ

๋‹ค. ์ง€๋ น ์ฃผํŒŒ์ˆ˜๊ฐ€ ์ธ๋ฒ„ํ„ฐ์— ๋ฐ˜์˜์ด ๋˜๋ฉด ์ฃผํŒŒ

์ˆ˜ ์„ค์ • ์™„๋ฃŒ2(RXD)๊ฐ€ ON๋ฉ๋‹ˆ๋‹ค.

์—ฌ๊ธฐ์„œ ์„ค์ •ํ•œ ์ง€๋ น ์ฃผํŒŒ์ˆ˜๋Š” ์ธ๋ฒ„ํ„ฐ ์ „์›์ด

OFF ํ›„ ๋‹ค์‹œ ON์„ ํ•ด๋„ ์ด์ „ ์ง€๋ น ์ฃผํŒŒ์ˆ˜๊ฐ€

๊ธฐ์–ต์ด ๋ฉ๋‹ˆ๋‹ค.

RYF ๋ช…๋ น์ฝ”๋“œ ์‹คํ–‰ ์š”๊ตฌ ๋ช…๋ น ์ฝ”๋“œ(RWw2) ์‹œํ–‰์„ ์š”๊ตฌ ํ•ฉ๋‹ˆ๋‹ค.

Page 50: iS7 CC-Link User Manual

iS7 CC-Link Manual

21

๋ช…๋ น ์ฝ”๋“œ๊ฐ€ Write ์š”๊ตฌ ์ธ ๊ฒฝ์šฐ RWw3์˜ ๋ฐ์ด

ํ„ฐ ๊ฐ’์ด ์œ ํšจ ํ•ฉ๋‹ˆ๋‹ค.

RY10

~19 ๋ฏธ์‚ฌ์šฉ

RY1A ์ธ๋ฒ„ํ„ฐ Reset

์ธ๋ฒ„ํ„ฐ๊ฐ€ Trip์ด ๋ฐœ์ƒํ•œ ๊ฒฝ์šฐ Trip ๋ฐœ์ƒ ์›์ธ์„

์ œ๊ฑฐ ํ•œ ํ›„ RY1A๋ฅผ ON์„ ํ•˜๋ฉด ์ธ๋ฒ„ํ„ฐ์˜ Trip

์ƒํƒœ๋ฅผ ํ•ด์ œํ•ฉ๋‹ˆ๋‹ค.

RY1B ๋ฏธ์‚ฌ์šฉ

RY1C

~1F ์‹œ์Šคํ…œ ์˜ˆ์•ฝ

9.3 ๋ฆฌ๋ชจํŠธ ์ž…๋ ฅ

๋ฆฌ๋ชจํŠธ ์ž…๋ ฅ(์ธ๋ฒ„ํ„ฐ โ†’ Master)

๋””๋ฐ”์ด

์Šค No ์‹ ํ˜ธ๋ช…์นญ ๋‚ด ์šฉ

RX0 ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ค‘ ON ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ค‘

OFF ์ • ๋ฐฉํ–ฅ ์šด์ „ ์ค‘ ์ด์™ธ

RX1 ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ค‘ ON ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ค‘

OFF ์—ญ ๋ฐฉํ–ฅ ์šด์ „ ์ค‘ ์ด์™ธ

RX2 ๊ฐ€์† ์ค‘ ON ์ผ ๋•Œ ๊ฐ€์† ์ค‘

RX3 ๊ฐ์† ์ค‘ ON ์ผ ๋•Œ ๊ฐ์† ์ค‘

RX4 ์†๋„ ๋„๋‹ฌ ON ์ผ ๋•Œ ์†๋„ ๋„๋‹ฌ

RX5 ๋ฏธ์‚ฌ์šฉ

RX6 ๋ฏธ์‚ฌ์šฉ

RX7 Relay1 ์ถœ๋ ฅ ์ž ON ์ผ ๋•Œ ์ž ์ถœ๋ ฅ

RX8 Relay2 ์ถœ๋ ฅ ์ž ON ์ผ ๋•Œ ์ž ์ถœ๋ ฅ

RX9 Q1 ์ถœ๋ ฅ ์ž ON ์ผ ๋•Œ ์ž ์ถœ๋ ฅ

RXA ๋ฏธ์‚ฌ์šฉ

RXB ๋ฏธ์‚ฌ์šฉ

RXC ๋ชจ๋‹ˆํ„ฐ ์ค‘

๋ชจ๋‹ˆํ„ฐ ๋ฐ์ดํ„ฐ๊ฐ€ ๊ฐฑ์‹  ์ค‘์ผ ๋•Œ ON๋ฉ๋‹ˆ๋‹ค.

๋ชจ๋‹ˆํ„ฐ ์ง€๋ น(RYC)์ด ON์ด๋ฉด ๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ

RWw0์— ํ•ด๋‹นํ•˜๋Š” ๋ชจ๋‹ˆํ„ฐ ๋ฐ์ดํ„ฐ๋ฅผ RWr0์—

์ €์žฅ์„ ํ•˜๊ณ  ๋ชจ๋‹ˆํ„ฐ ์ค‘(RXC)์ด ON๋ฉ๋‹ˆ๋‹ค.

๋ชจ๋‹ˆํ„ฐ ์ง€๋ น(RYC)์ด OFF์ด๋ฉด ๋ชจ๋‹ˆํ„ฐ

Page 51: iS7 CC-Link User Manual

iS7 CC-Link Manual

22

์ค‘(RXC)์ด OFF๋ฉ๋‹ˆ๋‹ค.

RXD ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์™„๋ฃŒ1

(RAM)

์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น1(RYD)์„ ON์œผ๋กœ ์„ค์ •ํ•ด์„œ

์ง€๋ น ์ฃผํŒŒ์ˆ˜๊ฐ€ ์ธ๋ฒ„ํ„ฐ์— ๋ฐ˜์˜์ด ๋˜๋ฉด ์ฃผํŒŒ์ˆ˜ ์ง€

๋ น ์™„๋ฃŒ1(RXD)์ด ON๋ฉ๋‹ˆ๋‹ค.

RXE ์ฃผํŒŒ์ˆ˜ ์„ค์ • ์™„๋ฃŒ2

(EEPROM)

์ฃผํŒŒ์ˆ˜ ์„ค์ • ์ง€๋ น2(RYE)๋ฅผ ON์œผ๋กœ ์„ค์ •ํ•ด์„œ

์ง€๋ น ์ฃผํŒŒ์ˆ˜๊ฐ€ ์ธ๋ฒ„ํ„ฐ์— ๋ฐ˜์˜์ด ๋˜๋ฉด ์ฃผํŒŒ์ˆ˜ ์ง€

๋ น ์™„๋ฃŒ 2(RXD)๊ฐ€ ON๋ฉ๋‹ˆ๋‹ค.

RXF ๋ช…๋ น ์ฝ”๋“œ ์‹คํ–‰ ์™„๋ฃŒ

๋ช…๋ น์ฝ”๋“œ ์‹คํ–‰ ์š”๊ตฌ(RYF)๊ฐ€ ON์ด๋ฉด ๋ช…๋ น์ฝ”๋“œ

RWw2์— ํ•ด๋‹นํ•˜๋Š” ๋ช…๋ น ์ฝ”๋“œ๊ฐ€ ์ฒ˜๋ฆฌ๊ฐ€

์‹คํ–‰๋ฉ๋‹ˆ๋‹ค. ๋ช…๋ น ์ฝ”๋“œ ์‹คํ–‰ ์™„๋ฃŒ ํ›„ ๋ช…๋ น์ฝ”๋“œ

์‹คํ–‰ ์™„๋ฃŒ RXF๊ฐ€ ON๋ฉ๋‹ˆ๋‹ค.

๋ช…๋ น ์ฝ”๋“œ ์‹คํ–‰ ์‹œ ์—๋Ÿฌ๊ฐ€ ๋ฐœ์ƒํ•˜๋ฉด ์‘๋‹ต ์ฝ”๋“œ

RWr2๊ฐ€ 0์ด์™ธ์˜ ๊ฐ’์ด ๋ฉ๋‹ˆ๋‹ค.

RX10

~19 ๋ฏธ์‚ฌ์šฉ

RX1A Trip ์ƒํƒœ ์ธ๋ฒ„ํ„ฐ์— Trip์ด ๋ฐœ์ƒํ•œ ๊ฒฝ์šฐ์— ONํ•ฉ๋‹ˆ๋‹ค.

RX1B ์šด์ „ ๊ฐ€๋Šฅ ์ƒํƒœ

์ธ๋ฒ„ํ„ฐ๊ฐ€ ์šด์ „ ๊ฐ€๋Šฅํ•œ ์ƒํƒœ์ผ ๋•Œ์— ONํ•ฉ๋‹ˆ๋‹ค.

์ธ๋ฒ„ํ„ฐ๊ฐ€ ์šด์ „ ๊ฐ€๋Šฅํ•œ ์ƒํƒœ๋Š” ์ธ๋ฒ„ํ„ฐ ์ „์›์ด ์•ˆ

์ • ๋˜๊ณ  ์ธ๋ฒ„ํ„ฐ Trip ๋“ฑ์ด ๋ฐœ์ƒ ํ•˜์ง€ ์•Š์€ ์ƒํƒœ

๋ฅผ ๋งํ•ฉ๋‹ˆ๋‹ค.

RX1C

~1F ์‹œ์Šคํ…œ ์˜ˆ์•ฝ

Page 52: iS7 CC-Link User Manual

iS7 CC-Link Manual

23

9.4 ๋ฆฌ๋ชจํŠธ ๋ ˆ์ง€์Šคํ„ฐ

(๋งˆ์Šคํ„ฐ-> ์ธ๋ฒ„ํ„ฐ)

๋ฆฌ๋ชจํŠธ

๋ ˆ์ง€์Šคํ„ฐ ๋ช…์นญ ๋‚ด ์šฉ

์‹คํ–‰

์š”๊ตฌ

RWw0 ๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ

๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ(RWw0)๋ฅผ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค.

๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ(RWw0)๋ฅผ ์„ค์ • ํ›„, ๋ชจ๋‹ˆํ„ฐ ์ง€

๋ น ํ”Œ๋ž˜๊ทธ(RYC)๋ฅผ ON์œผ๋กœ ์„ค์ •ํ•˜๋ฉด ๋ชจ๋‹ˆํ„ฐ

์ฝ”๋“œ์— ๋Œ€์‘ํ•˜๋Š” ๋ชจ๋‹ˆํ„ฐ ๋ฐ์ดํ„ฐ๊ฐ€ RWr0 ์—

์ €์žฅ ๋˜๊ณ  ๋ชจ๋‹ˆํ„ฐ ์ค‘(RXC)์ด ON๋ฉ๋‹ˆ๋‹ค.

RYC

RWw1 ์ง€๋ น ์ฃผํŒŒ์ˆ˜

(0.01 Hz Scale)

์ง€๋ น ์ฃผํŒŒ์ˆ˜๋ฅผ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค. ์ด ๋•Œ, RYD(์ฃผํŒŒ

์ˆ˜ ์„ค์ • ์ง€๋ น1) ํ”Œ๋ž˜๊ทธ๋ฅผ ONํ•˜๋ฉด, ์ด ์ง€๋ น

๋ฐ์ดํ„ฐ๊ฐ€ RAM์ƒ์— ์ €์žฅ์ด ๋ฉ๋‹ˆ๋‹ค. RYE(์ฃผํŒŒ

์ˆ˜ ์„ค์ • ์ง€๋ น 2)๋ฅผ ONํ•˜๋ฉด, ์ง€๋ น ์ฃผํŒŒ์ˆ˜ ๊ฐ’

์ด EEPROM์— ์ €์žฅ ํ•˜์—ฌ ์ธ๋ฒ„ํ„ฐ ์ „์›์„

OFF ํ›„ ๋‹ค์‹œ ON์„ ํ•ด๋„ ์ด์ „์˜ ์ฃผํŒŒ์ˆ˜๊ฐ€

๊ธฐ์–ต์ด ๋ฉ๋‹ˆ๋‹ค.

ํ†ต์‹ ์œผ๋กœ ์ฃผํŒŒ์ˆ˜ ์ง€๋ น์„ ๋‚ด๋ฆฌ๋ ค๋ฉด DRV-07

Ref Freq Src๋ฅผ โ€œFieldbusโ€๋กœ ์„ค์ •์ด ๋˜์–ด์•ผ

ํ•ฉ๋‹ˆ๋‹ค.

RYD

RYE

RWw2 ๋ช…๋ น ์ฝ”๋“œ

ํŒŒ๋ผ๋ฏธํ„ฐ์˜ ์ฝ๊ธฐ, ์“ฐ๊ธฐ, ์ด์ƒ ์ด๋ ฅ, ์—๋Ÿฌ

Reset ๋“ฑ์„ ์‹คํ–‰ ํ•˜๊ธฐ ์œ„ํ•œ ๋ช…๋ น ์ฝ”๋“œ๋ฅผ ์„ค

์ •ํ•ฉ๋‹ˆ๋‹ค. ๋ช…๋ น ์ฝ”๋“œ(RWw2)๋ฅผ ์„ค์ • ํ•˜๊ณ 

๋ช…๋ น ์ฝ”๋“œ ์‹คํ–‰ ์š”๊ตฌ ํ”Œ๋ž˜๊ทธ(RYF)๋ฅผ ON์œผ๋กœ

์„ค์ • ํ•˜๋ฉด ์ธ๋ฒ„ํ„ฐ๋Š” ๋ช…๋ น ์ฝ”๋“œ(RWw2)์— ๋Œ€

์‘ํ•˜๋Š” ์ฒ˜๋ฆฌ๋ฅผ ํ–‰ํ•œ ํ›„ ๋ช…๋ น ์ฝ”๋“œ ์‹คํ–‰ ์™„๋ฃŒ

ํ”Œ๋ž˜๊ทธ(RXF)๋ฅผ ONํ•ฉ๋‹ˆ๋‹ค.

๋ช…๋ น ์ฝ”๋“œ๊ฐ€ Write ์ธ ๊ฒฝ์šฐ RWw3์— ์“ฐ๊ธฐ

๋ฐ์ดํ„ฐ ๊ฐ’์„ ์„ค์ • ํ•ฉ๋‹ˆ๋‹ค.

RYF

RWw3 ์“ฐ๊ธฐ ๋ฐ์ดํ„ฐ

๋ช…๋ น์ฝ”๋“œ์™€ ์“ฐ๊ธฐ ๋ฐ์ดํ„ฐ๋ฅผ ์„ค์ • ํ›„, ๋ช…๋ น ์ฝ”

๋“œ ์‹คํ–‰ ์š”๊ตฌ ํ”Œ๋ž˜๊ทธ(RYF)๋ฅผ ON์œผ๋กœ ์„ค์ •

ํ•ด์•ผ ํ•ฉ๋‹ˆ๋‹ค.

Page 53: iS7 CC-Link User Manual

iS7 CC-Link Manual

24

(์ธ๋ฒ„ํ„ฐ -> ๋งˆ์Šคํ„ฐ)

๋ฆฌ๋ชจํŠธ

๋ ˆ์ง€์Šค

ํ„ฐ

๋ช…์นญ ๋‚ด ์šฉ ์‹คํ–‰

์š”๊ตฌ

RWr0 ๋ชจ๋‹ˆํ„ฐ ๋ฐ์ดํ„ฐ

๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ(RWw0์˜ ์ƒ์œ„ Byte)์— ๋Œ€์‘

๋˜๋Š” ๋ชจ๋‹ˆํ„ฐ ๋ฐ์ดํ„ฐ๊ฐ€ RWr0์— ์ €์žฅ์ด ๋˜

๊ณ  ๋ชจ๋‹ˆํ„ฐ ์ค‘(RXC)์ด ON๋ฉ๋‹ˆ๋‹ค.

RYC

RWr1 ์ถœ๋ ฅ ์ฃผํŒŒ์ˆ˜ RYD

RYE

RWr2 ์‘๋‹ต ์ฝ”๋“œ

๋ช…๋ น ์ฝ”๋“œ(RWw2)์™€ ์“ฐ๊ธฐ ๋ฐ์ดํ„ฐ(RWw3)

๊ฐ€ ์ •์ƒ์ ์ธ ๊ฒฝ์šฐ๋Š” ์‘๋‹ต ์ฝ”๋“œ(RWr2)์—

0x00์ด ์„ค์ • ๋˜๊ณ  ์˜ค๋ฅ˜๊ฐ€ ์žˆ๋Š” ๊ฒฝ์šฐ์—๋Š”

0x01~0x03์˜ ๊ฐ’์ด ์„ค์ •๋ฉ๋‹ˆ๋‹ค. RYF

RWr3 ์ฝ๊ธฐ ๋ฐ์ดํ„ฐ ๋ช…๋ น ์ฝ”๋“œ(RWw2)๊ฐ€ Read ์ธ ๊ฒฝ์šฐ ์ด์—

๋Œ€์‘ํ•˜๋Š” ์ฝ๊ธฐ ๋ฐ์ดํ„ฐ๊ฐ€ ์„ค์ •๋ฉ๋‹ˆ๋‹ค.

Page 54: iS7 CC-Link User Manual

iS7 CC-Link Manual

25

9.5 ๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ

.

Instance ID Object Name

์œ„ ์ƒ์œ„ 1Byte ํ•˜์œ„ 1Byte

0x00 ๋ชจ๋‹ˆํ„ฐ ์•ˆ ํ•จ -

0x01 ์ถœ๋ ฅ ์ฃผํŒŒ์ˆ˜ 0.01 Hz

0x02 ์ถœ๋ ฅ ์ „๋ฅ˜ 0.01 A

0x03 ์ถœ๋ ฅ ์ „์•• 1V

0x04 ์ง€์› ์•ˆ ํ•จ

0x05 ์„ค์ • ์ฃผํŒŒ์ˆ˜ 0.01Hz

0x06 ์šด์ „ ์†๋„ 1 rpm

0x07 ๋ชจํ„ฐ ์ถœ๋ ฅ ํ† ํฌ 0.1%

0x08 DC Link ์ „์•• 1 V

0x09~0x0C ์ง€์› ์•ˆ ํ•จ

0x0D ์ง€์› ์•ˆ ํ•จ 0.1kW

0x0E ์ถœ๋ ฅ ์ „๋ ฅ 0.1kW

0x0F ์ž…๋ ฅ ์ž ์ƒํƒœ ์ฃผ1)

0x10 ์ถœ๋ ฅ ์ž ์ƒํƒœ ์ฃผ2)

0x11~0x15 ์ง€์› ์•ˆ ํ•จ

0x16 ์ธ๋ฒ„ํ„ฐ ์šด์ „ ์ƒํƒœ ์ฃผ3)

0x17 ์ธ๋ฒ„ํ„ฐ ์šด์ „ ์‹œ๊ฐ„ Hour

์ฃผ1) ์ž…๋ ฅ ์ž Bit ์ •๋ณด

- - - P11 P10 P9 P8 P7 P5 P4 P3P6 P2 P1

13 12 11 10 9 8 7 6 4 3 25 0

RWr3

1

- -

15 14

๊ฐ ์ž ์ž…๋ ฅ ์ƒํƒœ ON ์‹œ : 1

๊ฐ ์ž ์ž…๋ ฅ ์ƒํƒœ OFF ์‹œ : 0

Page 55: iS7 CC-Link User Manual

iS7 CC-Link Manual

26

์ฃผ2) ์ถœ๋ ฅ ์ž Bit ์ •๋ณด

- - - - - - - - Q3 Q2 Q1Q4 R2 R1

13 12 11 10 9 8 7 6 4 3 25 0

RWr3

1

- -

15 14

๊ฐ ์ถœ๋ ฅ ์ž ์ƒํƒœ๊ฐ€ ON ์ด๋ฉด : 1

๊ฐ ์ถœ๋ ฅ ์ž ์ƒํƒœ๊ฐ€ OFF ์ด๋ฉด : 0

R1, R2๋Š” Relay1 Relay2๋ฅผ ์˜๋ฏธํ•จ.

์ฃผ3) ์ธ๋ฒ„ํ„ฐ ์šด์ „ ์ƒํƒœ Bit ์ •๋ณด

B15 0 : ์ •์ƒ ์ƒํƒœ

4 : Warning ๋ฐœ์ƒ ์ƒํƒœ

8 : Fault ๋ฐœ์ƒ ์ƒํƒœ

(PRT-30 Trip Out Mode ์„ค์ •๊ฐ’์— ๋”ฐ๋ผ์„œ ๋™์ž‘ํ•ฉ๋‹ˆ๋‹ค.)

B14

B13

B12

B11

- B10

B9

B8

B7 1 : ์†๋„ ์จ์น˜ ์ค‘ 2 : ๊ฐ€์† ์ค‘

3 : ์ •์† ์ค‘ 4 : ๊ฐ์† ์ค‘

5 : ๊ฐ์† ์ •์ง€ ์ค‘ 6 : H/W OCS

7 : S/W OCS 8 : ๋“œ์›ฐ์šด์ „ ์ค‘

B6

B5

B4

B3 0 : ์ •์ง€

1 : ์ •๋ฐฉํ–ฅ ์šด์ „์ค‘

2 : ์—ญ๋ฐฉํ–ฅ ์šด์ „์ค‘

3 : DC์šด์ „์ค‘(0์†์ œ์–ด)

B2

B1

B0

Page 56: iS7 CC-Link User Manual

iS7 CC-Link Manual

27

9.6 ๋ช…๋ น ์ฝ”๋“œ

(1) Profile 1 ๋ช…๋ น์ฝ”๋“œ

COM-11 Opt Parameter2๋ฅผ 0(Profile1)์œผ๋กœ ์„ค์ • ์‹œ ์•„๋ž˜์™€ ๊ฐ™์€ ๋ฐฉ๋ฒ•์œผ๋กœ ๋ช…๋ น ๋ชจ๋“œ๋ฅผ

์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

๋ฆฌ๋ชจํŠธ ๋ ˆ์ง€์Šคํ„ฐ์— ๋ช…๋ น ์ฝ”๋“œ ๊ฐ’์„ ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค. ๋ช…๋ น ์ฝ”๋“œ์˜ ๊ฐ’์„ ์ฝ๊ณ  ๋ช…๋ น ์ฝ”๋“œ์—

ํ•ด๋‹นํ•˜๋Š” ์ž‘์—…์„ ์ˆ˜ํ–‰ ํ›„ ๋ฆฌ๋ชจํŠธ ๋ ˆ์ง€์Šคํ„ฐ RWr์— ์ˆ˜ํ–‰ ๊ฐ’์„ ์ €์žฅํ•ฉ๋‹ˆ๋‹ค.

3 2 1 0 (Nibble, 4Bit)

0 : Read1 : Write

0

0~7 (Status/Control Number)

< RWw2 >

0

๋ช…๋ น ์ฝ”๋“œ๋Š” ํฌ๊ฒŒ 2๊ฐ€์ง€๋กœ ๋ถ„๋ฅ˜ ๊ฐ€๋Šฅ ํ•ฉ๋‹ˆ๋‹ค.

์ฒซ์งธ COM-31~38 Para Status1~8 ํŒŒ๋ผ๋ฏธํ„ฐ์— ์„ค์ •ํ•œ Address ๊ฐ’์˜ ์ธ๋ฒ„ํ„ฐ ๋ฐ์ดํ„ฐ๋ฅผ

์ฝ์–ด์˜ค๋Š” ์ž‘์—…์ž…๋‹ˆ๋‹ค. ์ด ์ž‘์—…์„ ์ˆ˜ํ–‰ ํ•˜๊ธฐ ์œ„ํ•ด์„œ RWw2๋Š” 0x0000~0x0007๊ฐ’์„

์„ค์ •ํ•จ์œผ๋กœ์จ COM-31~38 Para Status1~8 ํŒŒ๋ผ๋ฏธํ„ฐ์— ์„ค์ •ํ•œ ์ธ๋ฒ„ํ„ฐ ๋ฐ์ดํ„ฐ๋ฅผ ์ฝ์–ด์˜ฌ

์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๋‘ ๋ฒˆ์งธ COM-51~58 Para Control1~8 ํŒŒ๋ผ๋ฏธํ„ฐ์— ์„ค์ •ํ•œ Address ๊ฐ’์— RWw3์˜ ์“ฐ๊ธฐ

๋ฐ์ดํ„ฐ๋ฅผ Write ํ•˜๋Š” ์ž‘์—…์ž…๋‹ˆ๋‹ค. ์ด ์ž‘์—…์„ ์ˆ˜ํ–‰ ํ•˜๊ธฐ ์œ„ํ•ด์„œ RWw2๋Š”

0x1000~0x1007๊ฐ’์„ ์„ค์ •ํ•จ์œผ๋กœ์จ COM-51~38 Para Control1~8 ํŒŒ๋ผ๋ฏธํ„ฐ์— ์„ค์ •ํ•œ

์ธ๋ฒ„ํ„ฐ Address์— RWw3์˜ ๊ฐ’์„ Write ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

(2) Profile 2

COM-11 Opt Parameter2๋ฅผ 1(Profile2) ๋กœ ์„ค์ • ์‹œ ์•„๋ž˜์™€ ๊ฐ™์€ ๋ฐฉ๋ฒ•์œผ๋กœ ๋ช…๋ น ๋ชจ๋“œ๋ฅผ

์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

Page 57: iS7 CC-Link User Manual

iS7 CC-Link Manual

28

๋ช…๋ น ์ฝ”๋“œ๋Š” ํฌ๊ฒŒ 2๊ฐ€์ง€๋กœ ๋ถ„๋ฅ˜ ๊ฐ€๋Šฅ ํ•ฉ๋‹ˆ๋‹ค.

์ฝ๊ธฐ ๋ช…๋ น ์ฝ”๋“œ์˜ ๊ฒฝ์šฐ RWw2์— ์ธ๋ฒ„ํ„ฐ ํ†ต์‹  ์ฃผ์†Œ๋ฅผ ์ž…๋ ฅ ํ•ด์„œ ์‚ฌ์šฉํ•˜์‹ญ์‹œ์˜ค.

์“ฐ๊ธฐ ๋ช…๋ น ์ฝ”๋“œ ์ˆ˜ํ–‰ ์‹œ ์ธ๋ฒ„ํ„ฐ ํ†ต์‹  ์ฃผ์†Œ์˜ ์ตœ์ƒ์œ„ Bit์„ Setํ•œ ๊ฐ’์„ RWw2์— ์ž…๋ ฅ ํ•˜๊ณ 

RWw3์— ๋ฐ์ดํ„ฐ ๊ฐ’์„ ์ž…๋ ฅํ•ด์„œ Write ์ˆ˜ํ–‰์ด ๊ฐ€๋Šฅํ•ด ์ง‘๋‹ˆ๋‹ค.

๋งŒ์•ฝ DRV-03 Acc Time์„ ๋ช…๋ น ์ฝ”๋“œ๋ฅผ ํ†ตํ•ด ์ฝ๊ณ  ์‹ถ์€ ๊ฒฝ์šฐ

RWw2์— 0x1103์„ ์ž…๋ ฅํ•˜๋ฉด ๋ฉ๋‹ˆ๋‹ค.

๋งŒ์•ฝ DRV-03 Acc Time์„ ๋ช…๋ น ์ฝ”๋“œ๋ฅผ ํ†ตํ•ด 50.0์ดˆ๋ฅผ ์“ฐ๊ณ  ์‹ถ์€ ๊ฒฝ์šฐ

RWw2์— 0x9103(์ตœ์ƒ์œ„ Bit๋ฅผ Set)์„ ์ž…๋ ฅํ•˜๊ณ  RWw3์— 500์„ ์ž…๋ ฅ ํ•˜๋ฉด ๋ฉ๋‹ˆ๋‹ค.

Page 58: iS7 CC-Link User Manual

iS7 CC-Link Manual

29

9.7 ์‘๋‹ต ์ฝ”๋“œ

๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ, ๋ช…๋ น ์ฝ”๋“œ์— ๋Œ€ํ•œ ์‘๋‹ต์„ RWr2์— ์„ค์ •ํ•ฉ๋‹ˆ๋‹ค.

์—๋Ÿฌ ์ฝ”๋“œ ๋‚ด์šฉ ์›์ธ

0x00 ์ •์ƒ ๋งˆ์Šคํ„ฐ๊ฐ€ ๋ณด๋‚ด์˜จ ๋ช…๋ น ์ฝ”๋“œ๊ฐ€ ์˜ฌ๋ฐ”๋ฅด๊ณ  ์ •์ƒ์ ์œผ๋กœ

์‹คํ–‰ ๋˜์—ˆ์Œ์„ ์˜๋ฏธํ•ฉ๋‹ˆ๋‹ค.

0x01 ๊ธฐ์ž… ๋ชจ๋“œ ์—๋Ÿฌ ๋ชจ๋‹ˆํ„ฐ ์ฝ”๋“œ RWw0, ๋ช…๋ น์ฝ”๋“œ RWw2์— ์ง€์›ํ•˜์ง€

์•Š๋Š” ๊ฐ’์„ ๊ธฐ์ž… ํ–ˆ์Œ์„ ์˜๋ฏธํ•ฉ๋‹ˆ๋‹ค.

0x02 ๋ช…๋ น ์ฝ”๋“œ ๋ถˆ๋Ÿ‰

COM-31~37 Status1~8 ํ˜น์€ COM-51~58

Control1~8์— ์—‰๋šฑํ•œ ์ฃผ์†Œ ๊ฐ’์„ ์ž…๋ ฅ ํ–ˆ์Œ์„

์˜๋ฏธํ•ฉ๋‹ˆ๋‹ค.

0x03 ์“ฐ๊ธฐ ๋ฐ์ดํ„ฐ ๋ฒ”์œ„ ์—๋Ÿฌ ์“ฐ๊ธฐ ๋ฐ์ดํ„ฐ ๋ฒ”์œ„ ๋ฏธ๋งŒ์ด๊ฑฐ๋‚˜ ์ดˆ๊ณผ์ธ ๊ฐ’์„ ์“ฐ๋ ค๊ณ 

ํ–ˆ์„ ๋•Œ ๋ฐœ์ƒํ•˜๋Š” ์—๋Ÿฌ ์ฝ”๋“œ ์ž…๋‹ˆ๋‹ค.

0x04 ์“ฐ๊ธฐ ๊ธˆ์ง€ ์˜์—ญ์— ์ˆ˜๊ธฐ

์ˆ˜ํ–‰ ์‹œ ์—๋Ÿฌ

์ฝ๊ธฐ ์˜์—ญ์— ์“ฐ๊ธฐ ๋™์ž‘์„ ์ˆ˜ํ–‰ ์‹œ ์•Œ๋ ค์ฃผ๋Š” ์—๋Ÿฌ ์ฝ”

๋“œ์ž…๋‹ˆ๋‹ค.

Page 59: iS7 CC-Link User Manual

Recommended