Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation

1

Product Details March 1, 2005 MK, Industrial Safety Systems Dept.

Page 2: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 2

The name, “ProSafe” has been Yokogawa’s brand in the safety market over many years. “ProSafe” is a mix word of “Professional” and “Safety”. We offer the know-how and expertise for plant safety.“RS” is a newly added abbreviation of “Responsive Solutions”.ProSafe-RS is named to provide the best answer for evolving safety environment as a total, integrated solutions for process industries.

ProSafe-RS product name  

Page 3: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 3

ProSafe-RS product color The color gives active image of “safety” and expresses our willingness to provide thebest safety solutions to customers.

Name of color: Terracotta Orange

Background of choosing the color:

Orange represents vitality. The color stands out and gives a ‘signal’ to people.

Orange has a image of positiveness. It represents that we are willing to play active role in calling customers’ attention for safety. Customers can easily recognize our product even from afar.

Page 4: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation Page 4 Confidenti

al

ProSafe-RS Projects by Country

Over 300 projects from 50 Over 300 projects from 50 countries!!countries!!

Feb. 2005 - Apr. 2008Feb. 2005 - Apr. 2008   

Algeria China Italy Netherlands SudanAngola Congo Japan Nigeria TaiwanAustralia Egypt Kazakstan Oman ThailandAustria France Korea Pakistan TurkeyBelgium Germany KSA Philippine UAEBrazil Hungary Kuwait Qatar UKBrunei India Macedonia Romania UkraineBulgaria IndonesiaMalaysia Russia USACanada Iran Mexico Singapore VietnamChili Iraq Morocco Spain Yemen

Page 5: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 5

Key messages to customers

ProSafe-RS is Yokogawa’s own product backed by field- proven CENTUM CS3000 technology and long years of experience in safety system.ProSafe-RS offers - Truly integrated system of DCS and SIS - Safety and high availability in a simple architectureProSafe-RS aims not only the integration of SIS to DCS, but also our consistent business frame “from sales to service & support”.

Page 6: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 6

Backed by CENTUM CS 3000 technology “Pair & Spare” CPU Redundant CPU module & I/O module Redundant network

from control highway to data bus in a module

V net

Field-proven CS3000 technology

Page 7: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 7

Product BU, Cover

A revolution in Safety Instrumented System

Expanding the Safety Spectrum ProSafe-RS offers something more beyond conventional ESD (emergency shutdown) system.

Page 8: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 8

Product BU, traditional DCS-SISProSafe-RS

- Integrated plant safety

Traditionally, DCS and SIS had been two separate systems, because they were built differently by separate vendors.We required separate- design- human-machine interface - manner for maintenance and - additional work to connect both systems, etc.

Page 9: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 9

Product BU, Overall features The world’s first truly

integrated safety controller

ProSafe-RS is certified SIS as SIL3 by TÜV in the integrated configuration.ProSafe-RS is integrated directly to V net of CENTUM CS3000. ProSafe-RS offers plant safety, availability, efficiency without compromise.

Functional Safety mark of TUV Rhineland

Page 10: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 10

Easy System Design -> No gateway / interface module is needed

for DCS-SIS Data Exchange.-> No separate layout and communication design

is needed for DCS system & SIS system.Ethernet

CS 3000 Eng. Safety system Eng.

V net

CS 3000 HIS

CS 3000 FCSSafety Controller

Product BU, one network

Page 11: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 11

Product BU, Overall features The world’s first truly

integrated safety controller

Benefits of integration:- Faster project implementation by one network, - Greater operational efficiency by one window, - Lower cost of ownership by one solution. Advantages in terms of SIS selection and configuration:- Simple choice by Single SIL3, - Availability by redundancy.

Page 12: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 12

Product BU, One process : one network, one window

One process : one network, one window

V net supports safety-related communications which has been certified by TÜV. It ensures the logical segregation of DCS and SIS.This breakthrough is the first for the process control world. The integrated DCS and SIS system can eliminate separate monitors for two systems.

Page 13: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 13

Product BU, One process : one network, one window

One network

requires no gateway or interface hardware for data exchange between SIS and DCS functions.eliminates the need to install a dedicated safety network.offers much simpler and quicker route to system realization without complex engineering effort for integration.reduces maintenance cost. lowering total manpower on large process plants.

Page 14: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 14

Data exchange between Safety controllers

V net

CS 3000 HIS

CS 3000 FCSSafety Controller

Safetycommunication

-> Safety Communication is available on Vnet.(Yokogawa original safety protocol, TUV certified)

No affect to safety comm.

Product BU, one network

Page 15: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 15

Data access to Safety Controller

V net

CS 3000 HIS

CS 3000 FCSSafety Controller

Safety Data to FCS

-> No interface module is required.

Product BU, one network

Tag access

Page 16: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 16

V net

CS 3000 FCSCPU node

Product BU, one network

CS 3000 HIS is V net

Timemaster

Time Synchronization by Standard V net function

GPS as an option (IRIG interface on SCS)

Page 17: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 17

Merits of Common ArchitectureStandard design of cabinet layoutStandard way of Hardware replacement

FIO

Page 18: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation ProSafe-RS R1.02 18

System configuration with HART module

FFCS-L

Vnet/IP

PRMHIS/ENGS

1BUS2BUS

FFCS-L

Vnet/IP

PRMHIS/ENGS

1BUS2BUS

Vnet

SENG

SENG

Vnet router

Before R1.02.00

HART Multiplexer

SCS

SCS

After R1.02.00

HART Safety Sensor

HART Equipment

HART signal go though ProSafe-RS

Without any HART devices.

HART signal

HART signalbetween MUX and

PRMvia Serial Communic

ation

HART signal

HART signal

SafetyValves

ControlValves

Page 19: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation ProSafe-RS R1.02 19

[Example]Maximum 5km in total.

Maximum 9 I/O node can be connected.

Fiber-optic cable Connector:

LC type (IEC60754-20 compliant) Recommended cable: Silica-Based Single-Mode Fiber(JISC6835 SSMA -9.3/125,IEC60793-2-50B1.1)

CPU node(SSC10□/50 □)

I/O node(SNB10D)

SNB10D: Max. 9 units

ESB Bus

ESB Bus

Possible to install I/O node at remote locations via fiber-optic cable.

Fiber-optic cable (4 cables)

I/O node(SNB10D)

I/O node(SNB10D)

Optical ESB Bus Repeater

V-net

ESB Bus

Mounting unit dedicated for optical modules

Page 20: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 20

Product BU, One process : one network, one window

One window

provides the same environment to monitor SIS and DCS in accustomed way.eases comparison of the control data and the safety data, as well as alarms for quick decision making.improves back-tracking analysis of integrated events.… one solutionreduces the time and cost required to total process safety.

Page 21: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 21

Tag access from HIS to DCS data and SCS data Integrated monitoring on HIS

V net

CS 3000 FCSProSafe-RS SCS

CS 3000 HIS

Product BU, One window

Integrated Monitoring - Faceplate - Trend - Graphic - System status - Alarm - SOE

Page 22: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation ProSafe-RS R1.02 22

Enhancements of CS 3000 Integration

New Safety Function for Manual Operation from HIS– Manual operation of a valve from HIS– Manual Reset PB from HIS– Manual operation and monitoring for

an analog output (4 to 20 mA) – * Safety functions certified by TUV

= Integrated functions with CS3000 is also included TUV Certification.

Support some functions same as CS3000 – Alarm suppression on HIS– User defined alarm processing levels– Plant hierarchy

*New version of CS3000 R3.08 is coming.

Page 23: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 23

System status Product BU, One window

SCS FCS

Page 24: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 24

Process alarm

ProSafe-RS

All of CS3000 and ProSafe-RS

Product BU, One window

Page 25: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 25

System Alarm

ProSafe-RS

All of CS3000 and ProSafe-RS

Product BU, One window

Page 26: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 26

1ms resolution

・ Time & Date・ Event name ・ Comment・ Data

Product BU, One window

Yellow shows the trip event

Page 27: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 27

Product BU, Simple solutions are always best

A single, simple, SIL3 solutionYokogawa’s state-of-the-art design miniaturizes SIS. Each single module (processor, input or output) is SIL3 rated featuring a dual architecture and extremely high diagnostic coverage factor of more than 99%.This architecture is simple to understand, design, install and maintain SIS.

Page 28: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 28

SIL3 will be achieved in single Input-CPU-Output module configuration

   - all redundant in a module using proven “Pair & Spare” CPU from CS3000 scheme

Single CPU module

Single Input module Single Output module

InputCircuit, MPU

Circuit, MPU

CPUMPU, memory

MPU, memory

OutputCircuit, MPU

Circuit, MPU

Product BU, single, simple, SIL3

Page 29: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 29

Product BU, Simple solutions are always best

Plug-in availabilityDual redundant module configuration for higher system availability and fault tolerance with no effect on SIL3. Redundant configuration is selectable part by part, such as redundant processor modules with single input and single output, or a single input and redundant output. This flexibility provides a combination of safety and economy.

Page 30: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 30

High availability will be reached by redundant module options of CPU module & I/O module.

- Proven redundant technology from CS3000 - Redundant options are selectable part by part!

Redundant CPU module

Redundant Input module

Redundant Output module

InputCircuit, MPU

Circuit, MPU

CPUMPU, memory

MPU, memory

OutputCircuit, MPU

Circuit, MPU

InputCircuit, MPU

Circuit, MPU

CPUMPU, memory

MPU, memory

OutputCircuit, MPU

Circuit, MPU

Product BU, Plug-in availability

Page 31: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 31

Module redundancy is for availability, not for safety.

System is still SIL3 if all of one side are fail.

InputCircuit, MPU

Circuit, MPU

CPUMPU, memory

MPU, memory

OutputCircuit, MPU

Circuit, MPU

InputCircuit, MPU

Circuit, MPU

CPUMPU, memory

MPU, memory

OutputCircuit, MPU

Circuit, MPU

Product BU, Plug-in availability

××

×

Page 32: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 32

Product BU, Highly scalable architectureProSafe-RS employs the same flexible and scalable hardware standards as the CS3000.ProSafe-RS system can be as small as one rack with power supply, processor, and up to around 100 I/O channels.System with a (pair of) powerful processor module can also be extend to support around 1000 I/O points.ProSafe-RS can be distributed which will support up to 64 stations in just one domain.

Page 33: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 33

*Target scan time

50 I/Os in a CPU rack

    * 50ms for 50 DIO points

1000 I/Os for a CPU rack and I/O racks

* 250ms for 1000 IO points

Total 10 racks(1000 points)

Distribution on Vnet 64 stations in a domain, 100 thousand tags

V net

Very Small

Large & distributed

Product BU, Highly scalable architecture

Page 34: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 34

DCS and SIS share the Vnet components (repeater/bus converter/gateway)

DCS and SIS are integrated physically, segregated logically.

Ethernet

BCV

Repeater

CGW

ENG HIS

CGW

SENG

OpticalRepeater

VnetDomain A

SafetyController Vnet

Domain B

VnetDomain C

OpticalRepeater

FCS

FCS

FCS

SafetyENG

HIS/ENG

SENG

FCSSafetyController

SafetyController Safety

ControllerSafety

Controller

SafetyController

FCS

Product BU, Highly scalable architecture

Page 35: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 35

Product BU, A breakthrough in size reduction

ProSafe-RS provides a breakthrough in SIS footprint and cabinet size comparing with traditional safety PLCs. These benefits are for all users, but particularly for any application where space or weight is at a premium such as - offshore platform or - remote equipment stations.

Page 36: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 36

Product BU, A breakthrough in size reduction

Upper blue area mentions about engineering with IEC 61131-3.

Page 37: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 37

Engineering tools IEC 61131-3 Function Block Diagram & Ladder

DiagramSystem & I/O configurationTest (Simulator on PC / Real target)Self documentationVersion Control

Page 38: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 38

Monitoring/Maintenance on Eng PCLogic status displaySystem status display & Diagnostic dialog

viewerSOE viewerForcing variables (Input, Output, Logic variables) Online partial logic modification (TUV to be

certified)

Page 39: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 39

Product BU, VigilantPlant

Page 40: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 40

Product BU, Solutions for the safety environment

The growing influence of functional safety standards (IEC 61508/61511, ANSI/ISA S84) are forcing processing companies to adopt.Yokogawa's commitment to IEC 61508 - combined with the intrinsic simplicity of ProSafe-RS provides the ideal platform to support this trend. Both ProSafe-RS and the Yokogawa organization have been certified to be in compliance with IEC 61508/61511.

Page 41: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 41

Product BU, Solutions for the safety environment

These area mentions about our history, current products and support for them.

Page 42: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 42

Product BU, Solutions for the safety environment

This network configuration is available. Control domain and safety domain integrated with BCV are also available.

Page 43: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 44

Integration BU, Features of ProSafe-RS

1. Meeting Safety StandardsThe safety standards IEC 61508 and 61511 that have world-wide recognition require precise safety requirements for process plants.Both the ProSafe-RS product and the YOKOGAWA organization have been certified by TÜV to be in compliance with IEC 61508 and 61511. ProSafe-RS is certified as SIL 3 in a single module configuration.

Page 44: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 45

Integration BU, Features of ProSafe-RS

2. High Degree of System AvailabilityWhile realizing SIL 3 capability on a single module, the CPU and I/O modules of ProSafe-RS can have dual-redundant configuration. This set-up drastically prevents unexpected plant shutdowns.

Page 45: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 46

Integration BU, Features of ProSafe-RS

3. Highly Scaleable ArchitectureProSafe-RS employs the same flexible architecture of CENTUM CS 3000 R3, allowing SIS functions to be configured for any size of application. ProSafe-RS can also meet configuration requirements including centralized and distributed systems.

Page 46: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 47

Integration BU, Example windowsControl Window : Control data from FCS and safety data from SCS can be monitored in a single window.Alarm Window : Alarms for both FCS and SCS are shown in the single Alarm Window. Operators can divide the window to show the alarm from SCS in the upper section and all of the alarms in the lower section.Tends

Page 47: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 48

VigilantPlant BU, Cover

Integrated Plant Safety Managementfor Alert Manufactures

Page 48: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 49

Integrated Plant Safety ManagementSafe plants call for more than emergency shutdown. Let’s look at the big picture.

Page 49: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 50

SEE CLEARLY

A Recurrent Ailment...

...and a Vigilant Remedy

Heavy operator workload by recurrent alarms

Alarm flooding going unattended:-Causes oversights, delays, and incorrect operations -Leads to unnecessary plant shutdown

Operators are able to focus on critical alarms and predictive alerts

AAASuite advanced alarm administrator:-Suppresses nuisance alarms automatically -Add and highlight value-adding alarms for quick and effective decision making

BEFORE AFTER

Page 50: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 51

KNOW IN ADVANCE

Protect Reactively, Analyze Retrospectively...

...or Predict, Avoid, and Minimize EmergencyReactive protection, with

little help to operators and little synergy with DCS

Conventional ESD system:- Dedicated human machine interface / network / database- Analyze events retrospectively, but realtime information for operator is cumbersome, slow, and limited

Seamless monitoring of safety data enables prediction of critical conditions

ProSafe-RS Safety Controller- Common HMI and unified event data for integrated safety management- Alerts operators of critical conditions before they reach emergency- Ensures SIL3 protection in case the process reaches emergency conditions

AFTERBEFORE

Page 51: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 52

ACT WITH AGILITY

Re-start-up is an intensive non-routine operation under extreme pressure

The ad-hoc approach:-A large amount of manual operations that demand extra care for timing and attention to detail

Scrambled Efforts...

...or Orderly Teamwork

Non-routine but smooth and reliable operation by navigator

Exapilot advanced operation navigator:-Interactive and graphical software for non-routine operational procedure-Assists interaction intensive procedure-Leverages accumulated know-how of experienced operators & engineers

BEFORE AFTER

Page 52: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 53

VigilantPlant BU, END

Page 53: ProSafe RS Introduction

Industrial Safety Systems Dept. Copyright © Yokogawa Electric Corporation 54

Thank you for your attention.