Uponor Smatrix MoveE N Q U I C K G U I D E

Page 2: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

2 U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

03 | 2015

Uponor Smatrix Move PLUSU K Q U I C K G U I D E

https://www.uponor.com/smatrix/downloads.aspx

Contents

Uponor Smatrix Move components ..............................2System example ................................................................2

Copyright and disclaimer ..............................................3

Preface ..........................................................................4Safety instructions ............................................................4Correct disposal of this product (Waste Electrical and Electronic Equipment) .......................................................4

Quick Guide ...................................................................5Installation ........................................................................6Setup the system ..............................................................7Operating mode ................................................................8Heating and cooling curve ................................................9Factory reset .....................................................................9

Technical data .............................................................10

Uponor Smatrix Move components

An Uponor Smatrix Move system may be a combination of the following components:

• Uponor Smatrix Move Controller H X-157 Wired (controller)

• Uponor Smatrix Sensor Outdoor S-1XX

• Uponor Smatrix Move Sensor Supply/Return S-152

System example

Page 3: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

3U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

Copyright and disclaimer

Uponor has prepared this installation and operation manual and all the content included solely for information purposes. The contents of the manual (including graphics, logos, icons, text, and images) are copyrighted and protected by worldwide copyright laws and treaty provisions. You agree to comply with all copyright laws worldwide in your use of the manual. Modification or use of any of the contents of the manual for any other purpose is a violation of Uponor’s copyright, trademark and other proprietary rights.

The presumption for the manual is that the safety measures have been fully complied with and, further, that Uponor Smatrix Move, including any components that are part of such system, covered by the manual:

• is selected, planned and installed and put into operation by a licensed and competent planner and installer in compliance with current (at the time of installation) installation instructions provided by Uponor as well as in compliance with all applicable building and plumbing codes and other requirements and guidelines;

• has not been (temporarily or continuously) exposed to temperatures, pressure and/or voltages that exceed the limits printed on the products or stated in any instructions supplied by Uponor;

• remain in its originally installed location and is not repaired, replaced or interfered with, without prior written consent of Uponor;

• is connected to potable water supplies or compatible plumbing, heating and/or cooling products approved or specified by Uponor;

• is not connected to or used with non-Uponor products, parts or components except for those approved or specified by Uponor; and

• does not show evidence of tampering, mishandling, insufficient maintenance, improper storage, neglect or accidental damage before installation and being put into operation.

While Uponor has made efforts to ensure that the manual is accurate, Uponor does not guarantee or warrant the accuracy of the information contained herein. Uponor reserves the right to modify the specifications and features described herein, or discontinue manufacture of Uponor Smatrix Move described at any time without prior notice or obligation. The manual is provided “as is” without warranties of any kind, either expressed or implied. The information should be independently verified before using it in any manner.

To the fullest extent permissible, Uponor disclaims all warranties, expressed or implied, including, but not limited to, the implied warranties of merchantability, fitness for particular purpose and non-infringement.

This disclaimer applies to, but is not limited to, the accuracy, reliability or correctness of the manual.

Under no circumstances shall Uponor be liable for any indirect, special, incidental or consequential damages or loss that result from the use of or the inability to use the materials or information in the manual, or any claim attributable to errors, omission or other inaccuracies in the manual, even if Uponor has been advised of the possibility of such damages.

This disclaimer and any provisions in the manual do not limit any statutory rights of consumers.

Page 4: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

4 U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

This quick start guide to serves as a reminder for experienced installers. We strongly recommend reading the full manual before installing the control system.

Safety instructions

Warnings used in this manual

The following symbols are used in the manual to indicate special precautions when installing and operating any Uponor equipment:

Warning!Risk of injury. Ignoring warnings can cause injury or damage components.

Caution!Ignoring cautions can cause malfunctions.

Safety measures

Conform to the following measures when installing and operating any Uponor equipment:

• Read and follow the instructions in the installation and operation manual.

• Installation must be performed by a competent person in accordance with local regulations.

• It is prohibited to make changes or modifications not specified in this manual.

• All power supply must be switched off before starting any wiring work.

• Do not use water to clean Uponor components.

• Do not expose the Uponor components to flammable vapours or gases.

We cannot accept any responsibility for damage or breakdown that can result from ignoring these instructions.

Power

Warning!The Uponor system uses 230 V AC, 50 Hz power. In case of emergency, immediately disconnect the power.

Technical constraints

Caution!To avoid interference, keep installation/data cables away from power cables of more than 50 V.

Correct disposal of this product (Waste Electrical and Electronic Equipment)

N OT E !Applicable in the European Union and other European countries with separate collection systems

This marking shown on the product or its literature indicates that it should not be disposed with other household wasted at the

end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.

Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.

Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes of disposal.

Preface

Page 5: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

5U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

Quick Guide

N OT E !This is a quick start guide to serve as a reminder for experienced installers. We strongly recommend reading the full installation and operation manual before installing the control system.

Warning!Electrical installation and service behind secured 230 V AC covers must be carried out under the supervision of a qualified electrician.

230 V AC50 Hz

POWER

N

PUMP P1

PUMP P2 *

OUTSIDE

WATER RETURN

In1/In2 ** In1/In2 **

WATER IN

SENSORS

SE

NS

OR

S

HE

ATC

OLD

*

NL

2

4

In2

In1

In1 In2

L

N

L

N

L

Ope

n

Com

mon

Clo

se

CONTACTTher ***

In1/In2 **

ACTUATOR 230 V

230 V 50 Hz

230 V 50 Hz

230 V 50 Hz

230 V 50 Hz

*) Connect either COLD or PUMP P2 (secondary heating/cooling circuit) to connection terminal.

**) Select one of the inputs (heating/cooling switch, pump control signal, or immersion thermostat) and set parameter 11 – Wired Input 1 selection, or parameter 12 – Wired Input 2 Selection, accordingly. The heating/cooling option can only be used in systems without a registered wireless thermostat.

***) Optional temperature limiter connection, fitted with a cable bridgre from the factory. Remove the bridge if a temperature limiter is to be used together with PUMP P1.

Page 6: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

6 U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

A B

C D E F

145

mm

Installation

Caution!Do not attempt to connect Uponor Smatrix Base thermostats to the controller. They are not suited for each other, and they may get damaged.

A. Attach the controller to the wall by using wall screws and plugs.

If the controller is installed inside a metal cabinet, then locate the antenna outside the cabinet.

B. Connect additional equipment, such as actuator(s), circulation pump(s), temperature sensors etc, and secure them with cable clamps.

C. Check that all wiring is complete and correct:

• Actuators • Heating/cooling switch • Circulation pump(s) • Temperature sensors

D. Ensure that the 230 V AC compartment of the controller is closed and the fixing screw is tightened.

E. Connect the power cable to a 230 V AC wall socket, or if required by local regulations, to a junction box.

F. Setup the system (see next page)

Page 7: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

7U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

Setup the system

Change the system parameter settings to setup the system.

13

14

C

12

15 11

16

C

10

17

1 2 3 4 5 6 7

9

18 8

19

C

7

20 6

21 5

22 4

23 3

24 2

0h

0h

1

1

0h

0h 2 10 12 14 16 18 20

C

P

C

AUTO

22 244 6 8

1 2

3

4

5 6

24 24

10 s

N OT E !Some system parameter settings are only accessible during the first 4 hours after power up. This is done to prevent mistakes after installation. If the locked system parameter symbol is displayed, the power to the controller has to be disconnected and reconnected again to modify these parameters. No settings are lost when disconnecting or after a power failure.

The settings available while in run mode is always accessible for change, and will not be locked.

To enter system parameter settings:

1. Press and hold the OK button for about 10 seconds.

2. The settings icon is displayed in the top left hand corner of the display, and the text Hot type, Cld type, or rEv type (depending of current operating mode) is displayed.

3. Use buttons < or > to locate a parameter (see list below) and press OK.

Some of these parameters require other parameters to activate them.

Menu Display Description

0 type Type of installation (heating and/or cooling)

1 Cur Heating curve

See page 9 for more information and a diagram

2 Hi Maximum supply temperature (heating mode)

3 Lo Minimum supply temperature (heating mode)

1 Cur Cooling curve

See page 9 for more information and a diagram

2 Hi Maximum supply temperature (cooling mode)

3 Lo Minimum supply temperature (cooling mode)

4 InSt Type of system (hydraulic installation)

5 th Not used by Move

6 tHty Not used by Move

7 BGAP Boost function if the difference between the supply and return temperature is too much

8 trF1 Not used by Move

Page 8: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

8 U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

Menu Display Description

9 trF2 Not used by Move

10 tr1o Not used by Move

11 in1 Wired input 1, select function

12 in2 Wired input 2, select function

13 OUSE Outdoor sensor selection (installed/wireless/wired/etc)

14 OUt Outdoor temperature, fixed value if outdoor sensor is not installed

15 ourF Not used by Move

16 ˚C Display unit

17 00:00 Time unit (AM/PM/24H)

18 GriP Valve and pump exercise

19 PUMP Pump start delay after the mixer valve has closed

20 ctrl Forced control of the actuator

21 PrH Floor/screed preheating program

22 dry Floor/screed drying program

23 ALL Factory reset

Press and hold the OK button for about 5 seconds

24 End Exit system parameter settings

4. Use buttons - or + to change parameter settings.

5. Use buttons < or > to locate parameter 24 (End) – Exit system parameter settings.

6. Press the OK button to exit the system parameter settings.

Operating mode

During normal operation, the controller is in run mode.

In run mode different operating modes can be selected, as well as setting current time and day, and selecting a scheduling program.

0h 2 10 12 14 16 18 20

C C

AUTO

22 244 6 8

P

Use buttons < or > to change operating mode. A box shows which mode has been selected.

Available operating modes and settings in run mode are the following.

Icon Operating mode

Holiday mode

Comfort mode

Automatic mode (default)

Sets operating mode according to set scheduling program

ECO mode

Stop mode

Time and day settings

Scheduled programs menu

Heating/cooling mode (only available if cooling is activated)

This mode requires system parameter 0 – Type of installation being set to rEv, but is hidden if system parameters 11 or 12 is set to HC.

Circulation pump

If a circulation pump is connected to the controller, it will run continuously (default setting) during normal operation.

To change this setting, go to system parameter 19 (PUMP) – Pump start delay, in the controller.

See section Setup the system for more information.

The Move controller can receive a pump demand signal to one of the wired inputs (input 1 or 2, parameter 11 or 12 set to C_b) from another controller in the system, turning on or off the circulation pump connected to P1.

Page 9: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

9U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

Heating and cooling curve

The heating and cooling curves for the Uponor Smatrix Move controller is shown in the diagram below. The diagram shows the calculated supply temperature, for each curve, at different outdoor temperatures. The controller uses the selected curve to operate the mixer valve, which in turn adjusts the supply temperature to the system.

80

70

60

50

40

30

20

1036 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 -2 -4 -6 -8 -10 -12 -14 -16 -18 -200

0,2

0,4

0,60,70,8

1

1,2

1,522,533,544,55

Supply temperature

Outdoor temperature

The choice of curve depends on a combination of different factors, such as how well insulated the house is, geographical location, type of heating/cooling system etc.

Example:

A poorly insulated house heated by a radiator system requires a higher curve value than an equivalent house with underfloor heating.

The curves in the diagram are also limited by maximum and minimum parameters set in the system (marked in the diagram with extra thick lines).

To change the heating and/or cooling curve:

1. Press and hold the OK button on the controller for about 10 seconds to enter the system parameters menu.

2. The settings icon is displayed in the top left hand corner of the display, and the text Hot type, Cld type, or rEv type (depending of current operating mode) is displayed.

3. Use buttons < or > to locate parameter 1 (Cur) – Heating curve, or 1 (Cur) – Cooling curve. They are identified using the heating or cooling symbol.

Heating curve: Default: 0.7 Setting range: 0.1 – 5, 0.1 increments

Cooling curve: Default: 0.4 Setting range: 0.1 – 5, 0.1 increments

4. Use buttons - or + to change parameter setting.

5. Press the OK button on the controller to confirm the change and return to the system parameter settings.

6. Repeat steps 3 through 5 to change the other curve settings, if needed.

Factory reset

To perform a factory reset, go to system parameter 23 (ALL) – Factory reset, in the controller.

Press and hold the OK button for about 5 seconds until the controller restarts.

See section Setup the system for more information.

Page 10: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

1 0 U P O N O R S M AT R I X M O V E · Q U I C K G U I D E

Q U I C K G U I D E

Technical dataGeneral

IP IP30 (IP: degree of inaccessibility to active parts of the product and degree of water)

Max. ambient RH (relative humidity) 85% at 20 °C

Controller

CE marking

ERP III

Low voltage tests EN 60730-1* and EN 60730-2-1**

EMC (electromagnetic compatibility requirements) tests EN 60730-1

Power supply 230 V AC +10/-15%, 50 Hz

Operating temperature 0 °C to +50 °C

Storage temperature -20 °C to +70 °C

Maximum consumption 75 W

Pump 1 output 230 V AC +10/-15%, 250 V AC 5 A maximum (L, N, PE)

Heating output 230 V AC +10/-15%, 250 V AC 5 A maximum (L, N, PE)

Cooling/pump 2 output 230 V AC +10/-15%, 250 V AC 5 A maximum (L, N, PE)

3-point control 2 TRIACS => 75 W max

Valve output 230 V AC ±10%,

Power connection 1 m cable with europlug

Connection terminals Up to 4.0 mm² solid, or 2.5 mm² flexible with ferrules

*) EN 60730-1 Automatic electrical controls for household and similar use -- Part 1: General requirements

**) EN 60730-2-1 Automatic electrical controls for household and similar use -- Part 2-1: Particular requirements for electrical controls for electrical household appliances

0682Usable in all Europe

Declaration of conformity:We hereby declare under our own responsibility that products dealt with by these instructions satisfy all essential demands linked to the R&TTE 1999/5/CE Directive dated March 1999.

Page 11: Uponor qg smatrix move 10 2015

UK

CZ

DE

DK

EE

ES

FI

FR

HR

HU

IT

LT

LV

NL

NO

PL

PT

RO

RU

SE

SK

1 1U P O N O R S M AT R I X M O V E · Q U I C K G U I D E