9
Lamp Start, Run-up time and Flicker Test (LSRF-1) Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: [email protected] Lisun Electronics (Shanghai) Co., Ltd Add: Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District, Shanghai, 201803, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: [email protected] Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: [email protected] Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: [email protected] Lead in CFL & LED Test Instruments

Lamp start-run-up-time-and-flicker-test

  • Upload
    -

  • View
    25

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Lamp start-run-up-time-and-flicker-test

Lamp Start, Run-up time and Flicker Test

(LSRF-1)

Brochure

Global Office of Lisun Electronics Inc. http://www.Lisungroup.com

Lisun Group (Hong Kong) Limited

Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,

Hong Kong

Tel: 00852-68852050 Fax: 00852-30785638

Email: [email protected]

Lisun Electronics (Shanghai) Co., Ltd

Add: Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District,

Shanghai, 201803, China

Tel: +86(21)5108 3341 Fax: +86(21)5108 3342

Email: [email protected]

Lisun Electronics Inc. (USA)

Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.

Email: [email protected]

Lisun China Factory

Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China

Tel: +86-189-1799-6096

Email: [email protected]

Lead in CFL & LED Test Instruments

Page 2: Lamp start-run-up-time-and-flicker-test

Lisun Electronics Inc. [email protected] www.Lisungroup.com

Dated 14th December, 2012, the EU officially released the (EU) NO 1194/2012 rules《Implementing

rules of the European Parliament and the EU Council Directive 2009/125/EC on the eco-design

requirements of directional lights, LED lights and related equipment requirements》.Compared with

《European Parliament and Council Directive 2005/32/EC implementing rules for non-directional

household lamps eco-design requirements》which posted by the European Commission Regulation

(EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and

eco-design requirements. Start and Run-up time as the two indicators functional requirements in the

industry has been more emphasis by manufacturers.

To meet EU ErP requirements, IEC60969 Self-ballasted Lamps for General Lighting Services

Performance requirements and Energy Star about Lamp Start, Run-up Time and Flicker Test. LISUN

developed ErP test system, the system hardware consists of PH3000 and LSP-500VAC; the software

consists of LST-3000 Lamp Start and Run-up Time Test and FLK-3000 Lamp Flick Test.

1. Transit Photometer (PH3000) The Luminous flux, illuminance and Brightness are the most basic physical quantity in photometric

test. PH3000 Transit Photometer is developed base on rapid sampling techniques. It applied with 12

Bytes, the maximum sampling rate of 10M Hz high-speed A / D which can be achieved rapidly high

speed measurement of varying light photometric parameters. Combined with computer can record

the sampled waveform. The PH3000 also can used as normal illuminance meter, it can measuring

luminous flux, brightness, illuminance and photometric parameters.

Specification:

Photocurrent measurement range: 0.005x10-7~19999x10-8A; the measurement range of

luminous flux, brightness and illuminance depend on the sensitivity of acquisition and detector;

Users can achieve calibrate and zero through the instrument panel keyboard;

12 A / D conversion accuracy, five digital display;

Fourth gear range automatically converted tenfold;

USB and RS232 communicate ports;

Instrument level: Class 1.

Sampling rate: setting the fastest 20kS/s

Record: working with computer software, the record width can be set;

-Page 1 -

Page 3: Lamp start-run-up-time-and-flicker-test

Lisun Electronics Inc. [email protected] www.Lisungroup.com

2. Programmable AC Power Source Meter (LSP-500VAC) LSP-500VAC Programmable AC Power Source combined with high power, low harmonic, high

stability pure sine wave and power meter functions. It’s suitable to power on electronic ballast, CFL

and low power household appliances. The LSP-500VAC has following characteristics:

Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform

feedback technology, low distortion power;

Applied with entire cycle high-precision measurement technology and high-speed sampling

technologies , panel of instrument will directly and accurately displays the power output of the

voltage, frequency, current, active power and power factor to achieve the integration of the

source table;

Applied with SCM control and measurement technology, high intelligence;

Applied with zero output impedance technology, the output equivalent impedance is almost zero

and further improve the stability of power supply;

Applied with isolated floating output technology, the power output and input have good isolation,

floating output, conducive to make sure power itself safety and operator's safety;

Perfect voltage, current anomalies and overheating protection, improve the reliability of power

supply;

Applied with power limiting technology to avoid strong interference on the power grid and other

electrical equipment, while facilitating reliable operation of the power supply itself;

The input voltage can be option via a toggle switch of panel mains 110V/220V;

The initial phase and end phase of the output voltage waveform can be set(0°-359°(±1°));

Measurement process can be programmed to control(1 to 50 memory groups, 1 to 9 steps for

each memory group);

Specification:

Input voltage: 110VAC or 220VAC±10% 50/60Hz;

Output frequency setting: 45.00-500.00Hz;

Output phase setting: 0°-359°(±1°);

Output voltage setting: AC 0.0-300.0V;

Maximum allowable output current: 0-150V(4.2A),0-300V(2.1A);

-Page 2 -

Page 4: Lamp start-run-up-time-and-flicker-test

Lisun Electronics Inc. [email protected] www.Lisungroup.com

The total voltage distortion: ≤0.3%(No load or full load resistive load);

Voltage stability(≤0.1%/30 minute);

Equivalent resistance(≤0.1(Zero-resistance design);

Load Regulation: ≤0.1%;

Frequency stability: ≤0.05%/30 minute;

Meter display

Item Frequenc

y Voltage Current

Peak

Current Power Power Factor

Range 45-500Hz 0.1-300V 0.001-4.200A 0.0-5.9A 0.1-1200W 0.000-1.000

Resolution 0.1Hz 0.1V 0.001A 0.1A 0.1W 0.001

Accuracy ±0.05%re

ading

±(0.4%

reading)

±(0.4%

reading)

±(1%

reading)

±(0.4%

reading)

±(0.001%

reading)

3. New Design Integrating Sphere Due to the LED luminaries such as LED street luminaries developed, to do 4π geometry

testing, it is hard to be hold in the traditional integrating sphere design. To solve this

problem, Lisun design a new kind of sphere.

1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40,

all tubes such as T5/T8/T12 and all kinds of luminaries

2. The hold base can be installed in the ceiling or down, it can be adjusted the height

3. Hold base has four power cables connect to the outside Power Supply and max is 5KW

Specification:

Diameter: 0.3m, 0.5m, 1.0m, 1.5m, 1.75m, 2.0m, 2.5m and 3.0m

The painting of integrating spheres is according to CIE Pub.No.84(1989)

-Page 3 -

Page 5: Lamp start-run-up-time-and-flicker-test

Lisun Electronics Inc. [email protected] www.Lisungroup.com

BaSO4 coating: ρ(λ)≥0.96(450nm~800nm) and ρ(λ)≥0.92(380nm~450nm)

Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ(λ)<1.5%

Order Number:

Lisun Model 1.0m 1.5m 1.75m 2m

IS-1.0MA IS-1.5MA IS-1.75MA IS-2.0MA

Square side opening IS-1.0MA33P IS-1.5MA55P IS-1.75MA66P IS-2.0MA77P

Cycle side opening IS-1.0MA33C IS-1.5MA55C IS-1.75MA66C IS-2.0MA77C

Remark:

The 55P in IS-1.5MA55P means the side opening is 50x50cm square size

The 55C in IS-1.5MA55C means the side opening is diameter=50cm cycle size

4. Standard Lamp Source

OSRAM Standard Lamp to calibrate the

spectrum and luminous flux with Lisun Lab

certification. The data can be traced NIM. The

Standard Lamp Source is used to calibrate the

integrating sphere system. The different size of

Integrating Sphere should choose the right

power of standard lamp source

Integrating Sphere

Size

Standard Lamp

Source

0.3m/0.5m SLS-10W

1m/1.5m/1.75m SLS-50W

2m/2.5m/3m SLS-100W

5. Standard Instrument Cabinet 19Inch (Optional) Combine all of the test instruments in a 19 inch standard Cabinet, makes the whole

systems looks nice and is simple to use

-Page 4 -

Page 6: Lamp start-run-up-time-and-flicker-test

Lisun Electronics Inc. [email protected] www.Lisungroup.com

6. Optical Fiber

1.5m length Connect the Spectroradiometer and integrating sphere

The next pages are the test report:

-Page 5 -

Page 7: Lamp start-run-up-time-and-flicker-test
Page 8: Lamp start-run-up-time-and-flicker-test