Primotech Energy Solution ( Solar Vertical)

•Primotech has three verticals-Solar,Led Solution & Energy consultancy services.

•Provides complete Solar EPC solutions.

•One of Largest independently owned solar roofing company in Delhi/Ncr

•Strong brand awareness and reputation.

•Diverse solar installation expertise .

•Registered Company Under Company Act. 1956.

•Energetic & Dynamic approach for Providing extraordinary benefits to our Clients.

•Strong Dealer Network across North India.

Page 3: Solar rooftop projects primotech

Minimum Requirement for solar Rooftop plants :

A southern orientation is ideal although, East and west facing roofs can still capture over 80% of the energy.

Minimize roof obstructions to maximize PV capacity and aesthetics as shading can significantly reduce energy production.

Plan for current and future landscaping, neighboring houses and roof “stick-ups”.

Approx. 100 sq. ft. of roof for every kW of PV capacity.

2.5 –5.0 kW for new homes depending size of home.

Need of grid connection for grid tied solar roof-top, net-metering is applicable where it is already enforced like Delhi, Gujarat, Andhra pradesh,kerala etc.

Page 4: Solar rooftop projects primotech

Major system components1. PV Module 2. Solar Charge Controller

1.

4. Battery 5. Load

3. Inverter

6.Monitoring system

Page 5: Solar rooftop projects primotech

Grid tied System

In grid tied systems, the system is interfaced with the state power grid.

Here, Solar takes the first priority to run the loads.

Second priority will be given to grid If the load exceeds the power

generated by solar or cloudy environment, system automatically switched

over to grid.

Third priority is given to DG sets which are much costlier than solar & grid

power, Grid tied system can also be configured without a battery bank.

Page 6: Solar rooftop projects primotech
Page 7: Solar rooftop projects primotech

Off-Grid System

Off Grid or stand-alone system refers to being independent of the state

grid. The design would support all the loads and sufficient back up would

be provided to cater the power needs under worst conditions.

One can go off-grid for low intensity loads. In other words, all equipment

having a power rating lesser than 500W can be taken off grid.

Page 8: Solar rooftop projects primotech
Page 9: Solar rooftop projects primotech

Hybrid and grid interactive System

Hybrid system is a smart system involving, solar, grid and diesel generator (DG). Here, Solar

takes the first priority to run the loads. Excess power generated will charge the battery

bank.

During night battery will support the loads till a safe battery voltage. System will switch

over to grid automatically below battery safe voltage. If GRID is not available and battery

has been discharged, PCU can command DG to start and supply power to the loads till Grid

or solar is restored.

Hybrid systems can also be configured as grid interactive systems where only solar and grid

are present. Here, the first priority is given to solar. Excess power generated will charge the

battery bank. During night battery will support the loads, till a safe battery voltage. System

will switch over to grid automatically below battery safe voltage. This would extend the

battery life and provide seamless power supply.

Page 10: Solar rooftop projects primotech

Schematic Diagram For Hybrid System

Page 11: Solar rooftop projects primotech

Site Survey

Phase-I

Page 12: Solar rooftop projects primotech
Page 13: Solar rooftop projects primotech

Energy Audit

Phase-II

Page 14: Solar rooftop projects primotech

Energy Audit Sample sheet

Energy Audit Formula sheet for Site survey

Electrical Appliances

Nature of appliances Watt Quantity TOTAL W USAGE OF HRS. TOTAL W CONSUMED

Fan 80 2 160 6 0.96

Tube light 36 8 288 9 2.592

A.C (1 tonn) 1750 1 1750 6 10.5

Laptop/Desktop 150 3 450 5 2.25

PRINTER 200 2 400 3 1.2

Refrigerator (180 L) 550 1 550 8 4.4

Colour T.V 150 2 300 5 1.5

Total load : 3.848 Kw Total Wattages (Kwh) 23.402

Page 15: Solar rooftop projects primotech

Load Segregation

Critical Loads:

A.C, PA System, Water pump for extinguisher, Submersible water pump ,

Inverter, Refrigerator, Heater , Kettle, Geyser,Lift

Non-critical loads :

Fan, C.F.L, Tubelight , Downlighters , Kent RO,LED Lights,Pole

light,Laptop,Desktop printer, Projectors, Cooler,Chimney

Page 16: Solar rooftop projects primotech

Phase-III

Installation & commissioning

Page 17: Solar rooftop projects primotech

Type-1 (M.S Base) Ankel fastner through chemical fixer

Page 18: Solar rooftop projects primotech

Type-2 (M.S Base) RCC & PCC

Page 19: Solar rooftop projects primotech

Phase-IV

Performance & Cost benefit

Analysis

Page 20: Solar rooftop projects primotech

25 Kw grid-tied system

Page 21: Solar rooftop projects primotech

25 Kw grid-tied system

Page 22: Solar rooftop projects primotech

Evaluation of production probability forecast:

Page 23: Solar rooftop projects primotech

Payback Period

Page 24: Solar rooftop projects primotech

TARGET CLIENTS :

Small,Medium & Large Industries

Homes & offices

Govt./Pvt. Hospitals

Educational Institutions & Schools

Commercial Buildings & Shopping malls

Hotels & Resorts

Page 25: Solar rooftop projects primotech

Scope of work : EPC Turnkey Solution

Page 26: Solar rooftop projects primotech

EPC solutions

Promoting:

Identifying location of appropriate project sites

Discussion with necessary authorities

Conducting basic processes for obtaining

licenses and procedural permits.

Engineering :

Suitability and estimation of production

Basic and detailed engineering

Conduct geological and topographical studies

Execute civil works design

Mechanical design and specs definition

Electrical LV/HV design and specs definition

Grid connection design and specs definition.

Page 27: Solar rooftop projects primotech

Procurement :

Qualified vendors portfolio

Invite for quotation

Supplier selection

Quality supervision and inspection at supplier

facilities

Deliveries follow up

Construction:

Project management

Planning and schedules/follow up

Coordination with customers

Quality contractor assurance

Page 28: Solar rooftop projects primotech

Commissioning:

Document and drawing of the executed project

Detailed quality review

Project set up

Project commissioning

Project handover to owner

Silver Start offers preventive and corrective

maintenance services for solar plants

Offers monthly reporting on generation and activities

Operation and Maintenance:

Silver Start offers preventive and corrective

maintenance services for solar plants

Offers monthly reporting on generation and activities

Page 29: Solar rooftop projects primotech

OUR ASSOCIATE PARTNERS:

Page 30: Solar rooftop projects primotech

PRASHANT SHARMA

E-mail : ([email protected])

Contact no : 9811166461

MAHESH KUMAR GUPTA –E-mail : [email protected])-Contact no : 9891129272

DANISH MOHD. TAHIR –

E-mail : ([email protected])

Contact no : 7053491500

Contact Us for any Query: