35
Network Intelligent Alarm System User’s Manual V1.0 P/N:350310000868E010

Ks 868 e-users_manual of home security devices

Embed Size (px)

DESCRIPTION

home/commercial security alarms systems, fire & burglar alarms, network alarms, wireless & wired alarm systems, easy installation DIY home security, updated GSM & PSTN alarm panel, alarm host.

Citation preview

Page 1: Ks 868 e-users_manual of home security devices

Network Intelligent Alarm System

User’s Manual

V1.0P/N:350310000868E010

Page 2: Ks 868 e-users_manual of home security devices

Attachment List

Please check the complete attachment in the package before your

making installation and setting.

Directory

1.1 Brief introduction

1.2 Unit introduction

1.3 Spares specification

1.4 Sketch diagram of system running

2.1 Sketch diagram of the back of alarm unit

2.2 Wall-mounting installation

2.3 Sketch diagram of connecting interface

2.4 Wired detectors installation

2.5 Interface of alarm output

2.6 Enroll wireless detectors

3.1 Specification of beep

3.2 Arm/ Disarm

3.3 Alarm & alarm process

3.4 Remote operation

3.5 Events logs & Query

4.1 Index table of setting

4.2 Operation specification

4.3 How to set phone/CID

4.4 How to set Date

4.5 Arm/ Disarm Timer

4.6 Zone List

4.7 Zone Attributes

4.8 Modify pin

4.9 How to set delay

Summary

Installation & Connection

Operation Manual

How to set

Ⅳ (14)

(14)

(19)

(19)

(30)

(31)

(34)

(36)

(39)

(41)

(9)

(9)

(9)

(10)

(13)

(13)

(1)

(1)

(3)

(4)

(5)

(5)

(5)

(6)

(7)

(7)

(8)

(8)1pc

2pcs

4pcs

4pcs

1pc

4pcs

1pc

1pc

1pc

1pc

1pc

1pc

1pc

2pcs

4pcs

4pcs

1pc

4pcs

1pc

1pc

1pc

1pc

1pc

1.Alarm System (433SF-1)

Alarm Unit (433SF)

Wireless Remote Controllers

2.2K Sewing Resistances

M4 45Screws

M3 8Screws

Stopper

6 code connector base

3 code connector base

User’s Manual

Phone Line

Adapter

Alarm Unit (433SF/GSM/S)

Wireless Remote Controllers

2.2K Sewing Resistances

M4 45Screws

M3 8Screws

Stopper

6 code connector base

3 code connector base

User’s Manual

Phone Line

Adapter

12V 1300mAh NI-MH battery

2.GSM Alarm System (433SF/GSM/S-1)

Page 3: Ks 868 e-users_manual of home security devices

4.10 How to set Report

4.11 How to make enrollment

4.12 How to enroll wireless siren pin

4.13 Voice Record

4.14 Factory default

4.15 Installer Set

5.1 Alarm unit

6.1 Regular test

6.2 Clean the alarm unit

Technology Parameter

Maintenance

Exclude the Simple Troubles

The limitation of this alarm system

(61)

(61)

(61)

(61)

(61)

(48)

(53)

(56)

(57)

(58)

(59)

Foreword

Appreciate for your choosing this alarm system, which is reliable for its

certificates and multifunction.

It adopts the most advanced technology of digital sensor and

controlling. It is a kind of intelligent alarm control system, aggregated

with the features of Burglar, Anti-fire, Anti-gas, etc. Compatible with

CONTACT ID agreement enables the alarm system expanded usage

and stronger compatibility. With the excellent appearance and

powerful function, it can be widely used at home, community, financial

office and office building, etc.

To make sure the normal usage, please read the user’s manual before

your operation. Our company retains the right to modify and explain the

User’s Manual. Moreover, modified specification won’t be informed

specially.

Ⅰ Summary

1.1 Brief Introduction

1. LCD interface: English LCD screen, easy operation, working

running and alarm procure are of easy and simple usage.

2. Built-in antenna and latest design.

3. 16 wireless zones: 1-16 wireless zones. Each zone can enroll 3

detectors. Be compatible with the wireless detectors from our

company and easy to expand the wireless zones.

4. 4 wired zones: 13-16 wired zones. Act on NO/ NC alarm by

connecting with end-of-line resistor. It owns the functions of clew

for wired zones’ trouble and compelling Arm.

5. The modes of Multi-user and Mono-user can be exchanged. On

the mode of Multi-user, 8 remote controllers: 8 remote controllers

are assigned to 8 users. CID alarm center can identify the different

users by the pin of remote controllers; On the mode of Mono-user,

the user can Away Arm/ Home Arm the whole system.

6. 8 remote controllers: on the mode of Mono-user, 8 remote

controllers share 1 main user; on the mode of Multi-user, 8 remote

controllers refer to 8 users and the alarm center can distinguish

the directions from different users.

7. 8 alarm phone numbers can be set for users or CID.

8. Zone attributes can be set according to the attributes of the alarm

unit and 16 wireless zones. On-spot Alarm, linkage output and

wireless siren are for option. Individually setting to each zone is

also enabled. Zone attributes: 7 attributes are Burglar, Perimeter,

Duress, Panic, Fire, Gas and Medical.

9. Easy enrollment: Wireless detector, remote controller can be

enrolled with the alarm system automatically. Each zone / remote

controller can be enrolled and delete enrollment automatically &

independently.

1

(61)

(62)

Page 4: Ks 868 e-users_manual of home security devices

10. 20s voice record: Record / Playback are easy. 20s record can

be re-recorded at freedom.

11. The pin management: 1 installer ’s pin, 1 master’s pin, 8 users’

pins and Duress pin (the Duress pin is plus “1” to the last number

of master’s pin or user’s pin) (8 groups of user’s pins are valid on

the mode of Multi-user only).

12. Two groups of Timer Arm/ Disarm: to make two groups of Timer Arm/

Disarm according to the working day and resting day. Each group of

Timer Arm/ Disarm has a regular time to be set (Each group of Timer

Arm/ Disarm refers to one user on the mode of Multi-user).

13. Queried: It can record and query the 30 logs of alarm, including Away

Arm, Home Arm, Disarm, Line-cut, Zone Arm, Zone Disarm, low-power

of Zone, the alarm time and the alarmed zone.

14. Support alarm report, the zone list of alarm phone, Arm/ Disarm

information and report for Self-testing.

15. Communication time can be set as 00-99 hours. It supports the alarm

unit and alarm center, timer communication with the related user.

16. Delaying Alarm/ Arm time can be set as 000-255 seconds,

17. The alarm sound duration can be adjusted as 01-99 minutes.

18. Circulated dialing times and ringing times can be adjusted as 03-15 times.

19. Siren: the unit has equipped with inner siren. Meanwhile, it can connect

with wired siren in wire terminal and program with wireless siren

20. Three levels of alarm volume are optional.

21. Alarm line-cut: If the line of wired detector is cut, the alarm system will

make alarm at once. Meanwhile, if the phone line is cut, the unit will send

the warning tone.

22. NO and NC relay alarm output are suffered. Also 12V 150mA AC is

provided.

23. Remote operation: It can make the following actions by phone remotely,

such as Arm/ Disarm, monitor indoor, turn on-site alarm on the remote

phone.

24. GSM + PSTN alarm. The user can choose GSM wireless alarm or GSM

wireless with PSTN wired alarm together.

25. AC/ DC: Ext 220V voltage and inner with rechargeable batteries.

1.2 Unit introduction

Set Query Reset OK

1 23

4 5 6

7 8 9

0* #

LCD display

Horn

MIC

IndicatorDC Arm Alarm PSTN GSM

Picture 1 Sketch diagram of unit

Picture 2 LCD View

Picture 3 Sketch diagram in standby

2 3

Page 5: Ks 868 e-users_manual of home security devices

Set Query Reset OK

1 23

4 5 6

7 8 9

0* #

DC Arm Alarm PSTN GSM

1.4 Sketch diagram of system running

Ⅱ Installation & Connection

The phone line and connection wires of wired zones can be connected

by hiding on the back of the alarm unit. The alarm unit can be installed

wall-mounted or on the desk. It can be installed without opening the

cover. It has advantage of simple installation and safety.

2.1 Sketch diagram of the back of alarm unit

1.3Spares specification

DC” indicator

When DC supplied, the indicator is on.

When AC supplied, the indicator is off.

Arm” indicator

A)In Away Arm or Home Arm, the indicator will be on.

B)In Arm delay, the indicator will flash once per 2 seconds.

C)In Disarm, the indicator will be off.

Alarm” indicator: It is on, when making alarm. And vice versa.

PSTN” indicator

GSM” indicator:

A) ON: the GSM signal is normal.

B) Flash: the GSM signal is weak.

C) OFF: the GSM signal is in trouble or not existing, it will influence

the usage of GSM.

Note: if the GSM indicator is OFF after inserting for 3 minutes, the user

should check whether GSM module is connected well or not.

Function keys:

Press in standby status and input the correct user’s

pin to enter the program.

Query Press Query in standby status. The logs can be

inquired.

Reset Delete the previous inputted or exit to previous status.

OK Confirm what users inputted

Number key: Be used to set and Arm/ Disarm.

③ “

④ “

⑤ “

:

:

:

:

[Set] [Set]

[ ] [ ]

[ ]

[ ]

,-

.$

/0

*Yes

#No0

!" #$ %&' ()'

1*+ 2*+ 3*+ 4*+ 5*+ 6*+ 7*+ 8*+

Picture 1Wiring slot

Battery case

Wiring terminal

Tamper switch

4 5

Page 6: Ks 868 e-users_manual of home security devices

2.2 Wall-mounting installation 2.3 Sketch diagram of connecting interface

2.4 Wired detectors installation

Wired zones adopt AD converting technology and can be connected with

2.2K end-of-line resistor, which make sure the reliability of alarm system.

The power of wired detector was suffered by 12V output terminal of alarm

system. The output terminal of every detector connects with the connection

and GND of the corresponding zone by end-of-line resistor as picture

showing:

80mm 80mm

10

5m

m

Under mounting hole

Upper mounting hole

Picture 2

Picture 3

M4x45

Picture 4

M3x8

1) Take the hang-up board from the back of the alarm unit, and fix four

plugs and one M4 45 screws on the wall accordingly (as Picture 2).

2) Draw the one set of 6 pin Wired Holder and two sets of 3 pin Wired

Holders. Connect with power and wired zones, etc. Then insert the

related Wired Pillar and Phone Line. Hang the alarm unit on the screws

as pictures 6 and Picture 7.

3) After finishing connecting, pull the three holes of the back of alarm

unit up the related holes of hang-up board (as Picture 3).

4) Tighten the bottom of hang-up board with the back of alarm unit by

M3 8 screw (as Picture 4).

×

×

Picture 5

K2 OFFON

Line-cut test switch( )

( )

OFF

On

LINEPHONE

Phone

Phone connection

Volume: L-HK1 OFFON

Battery switch( )

( )

OFF

On

SW1

Note:

The power of detector suffered by the alarm system should not more

than 12V power (or 150mA). Otherwise, it should be suffered with 12V

backup power EXT.

When there are not wired zones connected, the wired zones should

also be connect with end-of-line resistor to make sure the alarm system

working normally.

6 7

Page 7: Ks 868 e-users_manual of home security devices

1.NO connection: The output terminal adopts paralleled connection

between end-of-line resistor and NO output detector.

2.NC connection: The output terminal adopts tandem connection

between end-of-line resistor and NC output detector.

3.Integrated connection: When there are NO output detector and NC

output detector, it can adopt integrated connection. The ways of

connection are showed as Picture a & Picture b:

2.5 Interface of alarm output

1. This interface is to connect the wired

siren or alarm light, etc. The way of

connection is showed as Picture c.

2. The connection loading is 1A 120V AC/

1A 24V DC, when the loading of

controlled circuit is too large, it should be

suffered with power independently to avoid destroying the alarm

system. Please visit Picture d:

2.6 Enroll wireless detectors

1.Install the enrolled detectors in the effective range from alarm system

as the user’s manual of wireless detector describing. Make sure to test

for the detector and the alarm system.

2.Wireless transmitting function: The alarm system may not receive the

signal from wireless detectors due to far distance or wall-shading

between wireless detector and alarm system, the wireless repeater from

our company can be chosen to lengthen the transmitting distance.

Ⅲ Operation Manual

3.1 Specification of beep

3.2 Arm/ Disarm

On the mode of

Multi-user, 1-8 remote controllers are corresponded to 1-8 users.

On the mode of Mono-user, 1-8 remote controllers are corresponded to

1 user. If the alarm systems connect with CONTACT ID, the alarm center

will record every master by its corresponding user. It is convenient to query.

3.2.1 Armed/ Disarmed by the remote controller.

3.2.2 Shortcut of Arm/ Disarm in alarm unit

On the mode of Mono-user:

Away Arm shortcut:A) In Disarm status, press “4” until hearing beep of

“Di”. Then release it. Input the master’s/user’s pin and on the

interface of entering. If the pin input is correct, the system will enter a

status of Away Arm. (When Delay Arm of the system was set to be 0s)

[OK]

B) In Disarm status, press “4” until hearing beep of

“Di”. Then release it. Input the master’s/user’s + and on the

interface of entering. If the pin input is correct, the system will enter a

status of Home Arm. (When Delay Arm of the system was set to be 0s)

Home Arm shortcut:

[#] [OK]

A short “Di” Arm

Two short “Di” Disarm

A short “Di” per 1s Delay Arm

Two quick short “Di… Di” per 1s Alarm Delay

A long “Di” per 15s Low power

Three quick short “Di…Di…Di” per 1s Phone line-cut

8 9

Page 8: Ks 868 e-users_manual of home security devices

Set Query Reset OK

1 23

4 5 6

7 8 9

0* #

DC Arm Alarm PSTN GSM

Set Query Reset OK

1 23

4 5 6

7 8 9

0* #

DC Arm Alarm PSTN GSM

C)Disarm shortcut: In Arm or Alarm status, press “4” until hearing beep

of “Di”. Then release it. You are required to input the master ’s/user ’s and

OK Input the correct pin and OK and the system enters Disarm status.「 」.

On the mode of Multi-user:

Away Arm shortcut:

Disarm shortcut:

A) In Disarm status, press “4” until hearing beep

of “Di”. Then release it. Input the corresponding master ’s/user ’s and

OK on the interface of entering. If the pin input is correct, the system

will enter a status of Away Arm. (When Delay Arm of the system was set

to be 0s)

B) In Arm or Alarm status, press “4” until hearing beep

of “Di”. Then release it. You are required to input the corresponding

master ’s/user ’s and OK Input the correct user ’s pin, the system

enters Disarm status.

Note: The pins are referred on Term of 4.8.

「 」.

3.2.3 Timer Arm/ Disarm

3.2.4 Remote Arm/ Disarm

Set Timer for Arm or Disarm accordingly. When the system runs to the

setting time, it will enter Away Arm/ Disarm automatically. (On the mode

of Multi-user, each group of Timer Arm/ Disarm is corresponded to one user.)

1) Remote Arm/ Disarm on phone

Please refer to Term of 3.4 remote operation.

2) Remote Arm/ Disarm on GSM (GSM module should be equiped)

Please refer to the User ’s Manual of GSM Module

3.3 Alarm & alarm process

When the zone is set as “Burglar” or “Perimeter”, the intruding alarm

won’t be made except the alarm system is in the status of Arm. And it

will be influenced by Delay Alarm Time. But for the Panic alarm, such as

Tamper Alarm, it will not be influenced by Delay Alarm Time whatever the

status the alarm system is.

When the zone is set as “Panic”, “Fire”, “Gas” or “Medical” etc, the system

will make alarm once the zone is triggered.

“Duress” is for special situations, such as there is required to make alarm

silently on spot.

3.3.1 Alarm attributes

3.3.2 Alarm Phone

When the alarm system receives the signal from detectors, it will activate

alarm at once and dial the set phones. The user will hear the recorded

voice on the phone. In the end of record, you will hear “Di”. You can

operate the alarm system on the key of phone within 5s (as Picture 8).

If the alarm won’t process within 5s, the alarm dialer will go on. If this user

have valid operation through phone, the alarm system will continue to dial

next phone. And won’t dial this user ’s again.

Input “2#” to eliminate the alarm, the alarm system will continue to dial

other pre-set phones.

Picture 8

10 11

Page 9: Ks 868 e-users_manual of home security devices

PS

TN

The alarm system sends the alarm signal to the alarm center; the center

will reply the alarm system with the confirmed signal. If receiving the

confirmed signal from the alarm center, it won’t dial alarm center again.

Or else, it will dial alarm center continually until the dial times arrives.

The alarm information is displayed and handled by the alarm center on

the computer.

3.3.3 The alarm center 3.4 Remote operation

The users can call the phone number that alarm unit connected to set

remotely. The user dials the phone number that alarm unit connected,

and waits for ring times arrives, the user will hear a DI, then have to input

the user ’s pin and #, if the user ’s pin corrects, you can set below..

3.5 Events logs & Query

Alarm, Away Arm, Home Arm, Disarm, phone

line-cut, Arm/ Disarm of detectors, Low voltage, battery restore, etc.

3.5.1 The alarm events are:

3.5.2 Query

Press Query in standby to inquiry the alarm logs (30 pieces at most).

If the total logs exceed 30 pieces, the oldest record will be deleted. Each

piece of record is signed as “nx” (“x” is the number of alarm logs).

Users can read the logs with pressing or

For example, when the alarm system is in standby status, you can

press to enter the query screen.

[ ]

[*] [#]

[Qurey]

.

3.3.4 The process of making alarm (Picture 9)

Picture 9Picture 1

Set Query Reset OK

1 23

4 5 6

7 8 9

0* #

DC Arm Alarm PSTN GSM

KS-868E (433.92MHz)

12 13

Picture 12

Page 10: Ks 868 e-users_manual of home security devices

Picture 2

Press to display the specifications: 18:18 July 1st Wednesday,

the first zone makes Perimeter Alarm as follows as Picture 2:

press to read next one

[OK]

[#]

3.5.3 Trouble

When there is a trouble existing, the screen will display as Picture 3:

it means there is trouble on the wired zone.

Press to display which wired zone is in trouble.[#]

Picture 3

Disarm

Fault

Picture 4

13 14 15 16Fault

Ⅳ How to set

Please read the following manual carefully before your usage. It is

suggested to make operation under the professional person guidance.

Note: We are not responsible for the default caused by wrong operation.

4.1 Index table of setting

4.1.1 On the mode of Mono-use

Set

Phone

Set the phones

Report for alarm information

Set the phone zones list

Set Report for Arm/ Disarm

Set Report for self-testing

The 1 phone numberst

The 2 phone numberst

The 3 phone numberst

The 4 phone numberst

The 5 phone numberst

The 8 phone numberst

Clock

Timer

Arm for the 1 Timerst

Disarm for the 1 Timest

Arm for the 2 Timernd

Disarm for the 2 Timernd

Zone

Attribute

Away Arm zones list

Home Arm zones list

Set the attribute of the alarm unit

Alarm on-spot for option

Integrated alarm output for option

Wireless siren for option

01 zone attribute

02 zone attribute

Set the attributes of 16 zones

Alarm on-spot for option

Wireless siren for option

Integrated alarm output for option

Burglar

Perimeter

Duress

Panic

Fire

Gas

Medical

Code

Installer' pin

Master's pin

14 15

Page 11: Ks 868 e-users_manual of home security devices

Delay

Set time of Delay Alarm

Set time of Delay Arm

Set time of Alarm sound

Set remote ringing times

Set the circulated dialing times of alarm receiving phones

Set time of Timer Communication

Report

System-setting modes for option

Mode of Mono-user

Mode of Multi-userRelay Report

Controlling switch of Alarm Center

Switch of compulsory Arm

Enrollment

Detector enroll

Enroll the detector of the1 zonest

Enroll the detector of the 2 zonend

Enroll the detector of the 16 zoneth

Enroll the 1 detectorst

Enroll the 2 detectornd

Enroll the 3 detectorrd

Enroll remote controller

Enroll the 1 remote controllerst

Enroll the 2 remote controllernd

Enroll the 8 remote controllerrd

Siren Code of wireless siren

Rec/ Play

Playback

Record

4.1.2 On the mode of Multi-user

Set

Phone

Set the phones

Report for alarm information

Set the phone zone list

The 1 phone numberst

The 2 phone numbernd

The 3 phone numberrd

The 4 phone numberth

The 5 phone numberth

The 8 phone numberth

Set Report for Arm/ Disarm

Set Report for self-testing

Clock

Timer

Arm for the 1 Timerst

Disarm for the 1 Timerst

Arm for the 2 Timernd

Disarm for the 2 Timernd

Set Arm/ Disarm Timer

Set zones list of the user

Zone

Away Arm zones list of the 1 userst

Away Arm zones list of the 2 usernd

Away Arm zones list of the 8 userth

Attribute

Set the attribute of the alarm unit

Alarm on-spot for option

Integrated alarm output for option

Wireless siren for option

01 zone attribute

02 zone attribute

Set the attributes of 16 zones

Alarm on-spot for option

Integrated alarm output for option

Wireless siren for option

Burglar

Users' list of the Timer Arm/ Disarm1st

Users' list of the Timer Arm/ Disarm2nd

Perimeter

Duress

Panic

Fire

Gas

Medical

16 17

Page 12: Ks 868 e-users_manual of home security devices

Code

Installer' pin

Master's pin

Delay

Set time of Delay Alarm

Set time of Delay Arm

Set time of Alarm sound

Set remote ringing times

Set the circulated dialing times of alarm receiving phones

Set time of Timer Communication

Report

System-setting modes for option

ON:Mode of Mono-user

OFF:Mode of Multi-userRelay Report

Controlling switch of Alarm Center

Switch of compulsory Arm

EnrollmentDetector enroll

Enroll the detector of the1 zonest

Enroll the detector of the 2 zonend

Enroll the detector of the 16 zoneth

Enroll the 1 detectorst

Enroll the 2 detectornd

Enroll the 3 detectorrd

Enroll remote controller

Enroll the 1 remote controllerst

Enroll the 2 remote controllernd

Enroll the 3 remote controllerrd

User's pin

the user's pin1st

the user's pin2nd

the user's pin8th

Siren Address pin of wireless siren

Record/ Playback

Playback

Record

4.2 Operation specification

4.3 How to set phone/ CID

* It adopts Menu to guide the users. In the standby status, you can press

and the alarm unit will require to input the user ’s pin and OK.

If the user ’s pin input is wrong with three times continually, the alarm

will be activated for one minute. Any operations are not allowed during

that time. The alarm will be locked 1 minute. After one minute, the user

can press Disarm by remote controller to unlock the alarm system.

* Right operation with a short “Di”; Wrong operation with a long “Di”.

* The alarm system will exit the standby status, if there is no operation

within 60s.

* Pressing Reset means coming back to the previous menu or deleting

the previous input.

* When the users set the alarm system, the users can press

and key to reach the menu they want.

* The setup is available only when the system is in standby. During the

set, the system won’t respond any alarm. After exit from set, the system

will enter Disarm. The users have to arm accordingly if need.

There are 5 sub-menus in Phone menu, as follows:

* Set alarm phone number

* Set alarm panel report

* Set zone list for alarm phone

* Set arm/disarm report

* Set self inspection report

[Set]

[ ]

[ ]

[*] [#]

[OK]

,

4.3.1 Set the alarm phones

* There are 8 alarm phones can be set. They can be set as Normal

Phones or CID Phones. To insure the priority of CID, please set the CID

alarm phone as the 1st alarm phone.

* 28 numbers can be included in the phone. The interface will turn a new

page when input 11 digits of number.

18 19

Page 13: Ks 868 e-users_manual of home security devices

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

1

Picture 3

Set

Telephone

1

Picture 4

Set

Telephone

1

Picture 5

Step 1: In standby, press Set

installer ’s pin to enter the

setup menu

[ ] + [

]+ [OK]

Step 4: Press 6789

If it sets successfully, the LCD

display will show PASS as Picture 7.

[12345678] + [#] + [ ]

+[OK].

Step 2: Press or to select

Phone Menu. When Phone Menu

flashes, press to enter.

[*] [*]

[OK]

Step 5: To set the number of “77880088”

as the second alarm center. Press or

to select “2” as Picture 8. It means

the 2nd phone number to be set when “

2” flashes as Picture 9-10, press

to enter.

[*] [

#]

[OK]

Step 3: It means the 1st phone

number to be set when “1” flashes,

press to enter.[OK]

Step 6: After inputting the numbers,

press to confirm and the screen

will display as Picture 11.

[OK]

Picture 7

31

Set

Telephone

2

Picture 8

Set

Telephone

Picture 6

Set

Telephone

1

Picture 9

2

Set

Telephone

2

Picture 10

Set

Telephone

2

Picture 11

Set

Telephone

20 21

*

*

Inputting [*] for 2s pause, the LCD screen will show “ ”.

Press the [phone numbers] + [OK]to setting the Normal phones;

Press [phone number] + [#] + 4-digit CID account] to set the CID

phone number. The 4-digit CID account should be in the range of

0000 9999. Input “#” , the LCD screen will show “ ”

The alarm system is connected with exterior line

directly. Now set the mobile phone number “12345678” in the 1st

alarm phone for CID, CID account 6789 Please read the following steps:

┘~ .

For example 1:

Page 14: Ks 868 e-users_manual of home security devices

3

!"

#$

3

Picture 2

Set

Telephone

For example 2: The alarm system is connected with exchange line.

The “0” is required before phone number. Now set the mobile phone

number “12345678901” as the third phone. There should be a pause

exchanger. Please read the following steps:

4.3.2 Set the information Report of the alarm unit, the zones list for

related alarm phones, Arm/ Disarm Report and the self-inspection Report.

When there is alarm occurring, “ON” is for Reporting to the alarm phones

and “OFF” is turn off Reporting.

The alarm panel report: emergency alarm activated by remote controller,

emergency alarm of main unit, Tamper alarm of alarm unit, alarm activated

by wrong pin input and duress alarm.

3

Picture 1

Set

Telephone

3

Picture 2

Set

Telephone

3

Picture 3

Set

Telephone

Step 1: In the phone menu, press or

to select “3”, when “3” flashes,

press to enter.

Step 2: Press 0 * 12345678901

If the setup is successful, the

LCD display will show the PASS.Once

the numbers is beyond 11 figures, the

next figures will be displayed on

next screen.

[*]

[#]

[OK]

[ ] + [

OK].

Step 1: In standby, press

Installer ’s pin OK to enter the

setup menu.

Step 2: Press or to select

Phone Menu. When Phone Menu

flashes, press to enter.

Step 3: Press or to select the

phone number (the phone number is

programmed ready), when “2” flashes,

press to choose turn on Reporting.

Then press to make sure and

continue to press to be in ON, to turn

on Reporting.

[Set] + [

] + [ ]

[*] [#]

[OK]

[*] [#]

[Set]

[OK]

[*]

2

2

nd

nd

The zone report: Burglar and Tamper of detector, etc.

Self-inspection information: Low power of alarm unit, battery restoration,

AC-off, AC restoration, low battery of detector, zone Bypass, zone

restoration, GSM communication failure, GSM communication restoration

and Timer communication, etc.

In the Phone menu, press key repeatedly to select the sub-menu,

When there is alarm occurring on the alarm unit, the alarm

unit will Report it by the alarm phone. The operation is as follows:

[Set]

For example 1:

2nd

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

1

Picture 3

Set

Telephone

2

Picture 4

Set

2

Telephone

Picture 5

22 23

Page 15: Ks 868 e-users_manual of home security devices

Picture 6

Set

2

Telephone

Picture 7

3

!"

#$

Set

Telephone

2

Step 4: When there is displaying PASS

on interface, it means the setting

is successful.

For example 2: When there is alarm on zone 01, 02, 06 and 12, the

system will dial the group of alarm phones. The operation is as follows:1st

For example 3: When there is alarm occurring on the alarm unit, the

system will send Arm/ Disarm Report by the 3rd alarm phone.

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

1

Picture 3Set

Telephone

1Zone

Picture 4

Step 1: In standby, press

Installer ’s pin to enter

the setup menu.

[Set] +

[ ] + [OK]

Step 2: Press or to select

Phone Menu. When Phone Menu

flashes, press to enter.

[OK] [#]

[OK]

Step 3: Press or to select

the phone number (the phone

number is programmed ready), when

“1” flashes, press twice to

reach “ Zones List” menu. Then

press to enter the menu. And

continue to press the zone number 01,

02, 06, 12.. Then press

[*] [#]

[Set]

[OK]

[OK]

1 1st st

Step 4: When there is displaying PASSon interface, it means the settingis successful.

3

!"

#$

Set

Telephone

1Zone

Picture 6

Set

Zone1

Telephone

Picture 5

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

1

Picture 3

Set

Telephone

3

Picture 4

Step 1: In standby, press

Installer ’s pin OK to enter the setup

menu.

Step 2: Press or to select

Phone Menu. When Phone Menu

flashes, press to enter.

[Set] + [

] + [ ]

[*] [#]

[OK]

24 25

Page 16: Ks 868 e-users_manual of home security devices

Set

3

Telephone

3

Picture 5

Set

3

TelephoneDisarm

Home Arm

Away Arm

Report

Picture 6

Step 3: Press or to select the

phone number (the phone number is

programmed ready), when “3” flashes,

press Set triple

to reach arm/disarm Reporting menu.

Press to enter, Press

to choose the ON. Then press

Step 4: When there is PASS

on interface, it means the setting is

successful.

[*] [#]

[ ]

[OK] [*]

[OK]

displaying

3

3

rd

rd

Set

3

Telephone

Disarm

Home Arm

Away Arm

Report

Picture 7

3

!"

#$

Set

Telephone

3

Disarm

Home Arm

Away Arm

Report

Picture 8

For example 4: When there is Arm/ Disarm on zone 01, 02, 03, the

system will dial the group of alarm phone. The operation is as follows:3rd

Picture 1

Pin

Picture 2

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 3

1

Set

Telephone

Picture 4

3

Set

Telephone

Picture 5

Zone3

Set

Telephone

Picture 6

3

Disarm

Home Arm

Away Arm

Report

Set

Telephone

Set

3

Disarm

Home Arm

Away Arm

Telephone

Report

Picture 7

33

Picture 8

SetTelephone

Disarm

Home Arm

Away Arm

Report

Step 1: In standby, press

Installer ’s pin OK to enter the

setup menu.

Step 2: Press or to select

Phone Menu. When Phone Menu

flashes, press to enter.

[Set] + [

t] + [ ]

[*] [#]

[OK]

Step 3: Press or to select the

phone number when “3” flashes,

press twice to reach “Zones

List” menu. Then press to enter

and continue to press the zone number

01, 02, 03. Then press

Step 4; Then press to reach the

menu of “Arm/ Disarm Report”. Then

press to enter, press to choose

ON. And Press to confirm

Step 5: When there is displaying

on interface, it means the setting

is successful.

[*] [#]

[Set]

[OK]

[OK]

[Set]

[OK] [*]

[OK]

PASS

3rd

26 27

Page 17: Ks 868 e-users_manual of home security devices

For example 5: When there is low power existing, the system will make

Report by the 6th alarm phone.

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Report6

under-voltage

Picture 7

3

!"

#$

Set

Telephone

6 Report

under-voltage

Picture 8

Report6

under-voltage

Picture 6

Set

1

Picture 3

Set

Telephone

6

Picture 4

Set

Telephone

66

Picture 5

Set

Telephone

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

1

Picture 3

Set

Telephone

6

Picture 4

Set

Telephone

28 29

For example 6: When there is low power on zone 03, the system will

make Report by the alarm phone.6th

Step 1: In standby, press

Installer ’s pin OK to enter

the setup menu.

Step 2: Press or to select

Phone Menu. When Phone

Menu flashes, press to enter.

[Set] + [

] + [ ]

[*] [#]

[Set]

Step 3: Press or to select the

phone number (the phone number

is programmed ready), when “6”

flashes, Then press repeatedly (

quartic) to reach menu of “l-power”.

press to enter the low power menu,

Press to choose ON. Then

press to confirm.

[*] [#]

[Set]

[OK]

[*]

[OK]

6

6

th

th

Step 1: In standby, press

Installer ’s pin to enter the

setup menu.

Step 2: Press or to select

Phone Menu. When Phone Menu

flashes, press to enter.

[Set] + [

] +[OK]

[*] [#]

[OK]

Page 18: Ks 868 e-users_manual of home security devices

Step 3: Press or to select the

phone number when “6” flashes,

press Set repeatedly to choose sub-

menu of Zones List. Input zone number

03 and Then press

repeatedly (quartic) to reach menu

of “l-power Report”. press to enter

the low power menu, Press to

choose ON. Then press to

confirm.

Step 4: When there is displaying

on interface, it means the

setting is successful.

[*] [#]

[ ]

[OK] [Set]

[OK]

[*]

[OK]

PASS

,

6th

4.4 How to set Date

For example 1:

This date can be set according to local time. It is very important for Timer

Arm/ Disarm and Record of alarm items. This alarm device have equipped

with real-time module.

xx (2-digits for year) + xx (2 digits for month) + xx (2-digits for day) + xx

Time (2-digits for hour) + xx(2-digits for minute) + x(1-digit for week)

The system will be set to be 15:30 Jan. 5th, 2011. Wed..

The operation is as follow:

6Zone 6

Set

Telephone

Picture 5

Report6

under-voltage

Set

Telephone

Picture 6

6

under-voltage

Set

Telephone

Report

Picture 7

3 6

under-voltage

Set

Telephone

Report

Picture 8

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Clock

Picture 3

Set

Clock

Year Month Date Hour Minute Week

Picture 4

3

!"

#$

Set

Clock

Picture 5

Step 1: In program, press or

to select t “Date”, when the “Date”

flashes, press to confirm.

[*] [#]

[OK]

Step 2: Input 11010515303 if

the setup is successful, the LCD

screen will show “PASS”

[ ]+ [OK]

4.5 Arm/ Disarm Timer

* On the mode of Mono-user:

There are two groups of timer. Each group is composed of Arm time and

Disarm time. The operation is as follows:

The sub-menu under arm/disarm timer,

1 is first group of arm timer

2 is first group of disarm time

3 is second group of arm time

4 is second group of disarm time

In the multi-user, press to select the menu of zone list.

x (2-digits for hour) + xx (2-digits for minute) + 1-7(1-7digits for week)

two groups of Arm time and Disarm time.

It can realize to Arm/ Disarm in different time.

[Set]

x

30 31

Page 19: Ks 868 e-users_manual of home security devices

* On the mode of Multi-user: two groups of Arm time and Disarm time are

corresponded to 8 users.

(Note: The specifications are referred to the term of 4.10.)

Note:

The time set for two groups are not allowed in the same. Otherwise,

the set is not useful.

On the mode of Mono-user, the system will turn off the function of “

Zones List of Timer Arm/ Disarm”.

Ȩ

Ȩ

For example 1: On the mode of Multi-user, the first group of timer of

01, 02, 03 zones, from Monday to Friday.

Arm time is 00:00, Disarm time is 08:00. The operation is as follows:

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

1

Picture 3

1

Set

Timer

Year Month Mon. Sun.~

Picture 4

3

!"

#$

Set

Timer1

Picture 5

2

Set

Timer

Picture 6

Set

Zone1

Timer

Picture 8

3

!"

#$

2

Picture 7

Set

Timer

1

Picture 9

Set

Zone

Timer

31

Picture 10

Set

Zone

Timer

Step 3: Press [*] or [#] to select “2”, “2”

is for disarm time of first group. Press [

OK] to confirm.

Step 4: Press [080012345] + [OK]

if the set is successful, the LCD will

show PASS.

[Set]

[OK]

[ ] + [OK]

Step 5: In program, press to

select the Zones List of Timer Arm/

Disarm, if this menu flashes, press

to enter.

Step 6: Press 010203 if

the set is successful, the LCD will show

PASS.

Note: “3” and “4” are for the Arm and Disarm for second group timer. Users

can set accordingly.

32 33

Step 1: In program, press or

to select the Timer, if Timer

Menu flashes, press to

enter.

Step 2: “1” is for Arm of first

timer, press to confirm.

Press 080012345

if the set is successful, the LCD

will show PASS.

[*] [

#]

[OK]

[OK]

[ ] + [OK],

Page 20: Ks 868 e-users_manual of home security devices

4.6 Zone list

On the mode of Mono-user:

On the mode of Multi-user:

For example 1:

* relate to the corresponding Arm/ Disarm

Zones List.

* relate to the corresponding Away Zones

List of 8 users. Each user ’s zones list can be set alternately.

(Note: The selection of modes of Mono-user and Multi-user can be

referred on the item of 4.10 “How to set Report”).

Note: A) The zone number should be fixed to be 2 figures.

B) The Zones List of Mono-user & Multi-user modes can be

conserved separately. If the user exchanges the mode, the Zone List

would return to Default State.

On the mode of Multi-user, set the Zones List of the 1st

user: 03, 04, 11, 16 zone. The operation is as follow:

Pin

Picture 1

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

1

Set

Zone

Away Arm

Picture 3

1

Set

Zone

Away Arm

Picture 3

Set

Zone1

Telephone

Away Arm

Picture 4

Set

Zone1

Telephone

Away Arm

Picture 4

3

!"

#$

Set

Zone1

Away Arm

Picture 5

Step 1: In program, and in Mode of

Multi-user. Press or to select the

Zone, when Zone menu flashes,

press to enter the item of “

Away Arm”.

Step 2: In the zone menu, there is “1”

existing, “1” for zone list. When “1”

flashes, press OK to confirm, the

press 03, 04, 11, 16 to set the

Zones List. If the program sets

successfully, the LCD display

will show PASS.

[*] [#]

[OK]

[ ]

[ ] + [OK]

For example 2: On the mode of Mono-user, set the Zones List of Away

Arm: 03, 04, 11, 16 zone; Set the Zones List of Home Arm: 01, 02, 03,

14, 15 zone

3

!"

#$

Set

Zone 1

Away Arm

Picture 5

Step 1: In program, supposed that the

Mode of Multi-user has been existed on

the item of “Report”. Press or to

select the Zone, when Zone menu

flashes, press to enter.

Step 2: In the zone menu, there have “1”

and “2”, “1” for zone list of Away arm, “2”

for zone list of home arm. When : “1”

flashes, press to confirm, the

press 03, 04, 11, 16 to set the

zone list of Away home. If the program

sets successfully, the LCD display will

show PASS.

Step 3: In this zone menu. Press

or to select “2” to set the zone list

of home arm, when “2” flashes, press

to confirm

[*] [#]

[OK]

[OK]

[ ] + [OK]

[*]

[#]

[

OK]

34 35

Page 21: Ks 868 e-users_manual of home security devices

Away Arm

Home Arm

Disarm

Burglar Perimeter Duress Panic Fire MedicalGas

2

Set

Zone

Home Arm

Picture 6

Picture 7

Set

Zone2

Home Arm

Picture 8

3

!"

#$

Set

Zone2

Home Arm

Step 4: Press 01, 02, 03, 14, 15

to set the zone list of home arm.

If the set is successful, the LCD screen

will show PASS.

[ ] + [

OK]

4.7 Zone Attribute

The system can set output of alarm panel. And set output and attributes

of each zone separately. There are three kinds of output. As follows

On-spot alarm. “1” is ON and “0” is OFF.

Linkage output, “1” is ON and “0” is OFF.

Wireless siren, “1” is ON and “0” is OFF.

There are 7 kinds of zone attributes. The users can define the different

zones according to the need. There are Burglar, Perimeter, Duress,

Panic, Fire, Gas and Medical attribute.

The Attribute of alarm output adopts 2 digits of binary system. The first

digit is for “on-spot Alarm”, the second one is for “linkage Output” and

the third one is for “Wireless Siren”. “1” is ON and “0” is OFF.

Note: “ means alarm can be activate when the system is triggered;

“×” means alarm can’t be activate when the system is triggered.

”√

For example 1: When there is Tamper alarm existing, the modes of

on-spot Alarm, Iinkage Output and Wireless Siren are opened.

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Attribute

Picture 3

Set

Attribute

Picture 4

Step 1. In the program, press or

to select Attribute. When Attribute Menu

flashes, press to enter.

Step 2: Input “111” to select the

modes of on-spot Alarm, Linkage

Output and Wireless Siren n.

Then press to confirm.

[*] [#]

[OK]

[OK]

36 37

Page 22: Ks 868 e-users_manual of home security devices

5

Set

Attribute

Burglar

Picture 4

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Attribute

Set

Picture 5

3

!"

#$

Set

Attribute

Picture 6

For example 2: Set zone 5 to be Perimeter. And open modes of Alarm

On-spot and Wireless Siren and turn off the mode of linkage output

when there is alarm existing.

Step 1. In the program, press or

to select Attribute. When Attribute

Menu flashes, press to enter.

Step 2: press or to reach “5” (“

5” is in flash). press to confirm

for zone number

Step 3: Input “101” to select the

modes of on-spot Alarm, Iinkage

Output and Wireless Siren.

[*] [#]

[*]

[*] [#]

[OK]

Set

Attribute

Picture 3

5

Set

Attribute

Burglar

Picture 5

5

Set

Attribute

Perimeter

Picture 6

Step 4. Press [*] or [#] to reach “

Perimeter” (“Perimeter” is in flash).

Press [OK] to confirm.

4.8 Modify pin

* On the mode of Mono-user: two levels of pins: “Installer ’s Code”

and “User ’s Code”

* On the mode of Multi-user: three levels of pins: “Installer ’s Code”, “

master ’s Code” and “User ’s Code”.

“Installer ’s Code”: in the status of installing, it can set for all the items.

It is set to be 6 digits of “000000-999999”. “000000” is default setting.

“master ’s Code”: it can set the items of Real-time, Timer Arm/ Disarm

and User ’s Code, etc. It is set to be 4 digits of “0000-9999”. “0000” is

default setting. Please revise the master ’s Code from your purchasing

to avoid letting the pin out.

“User ’s Code”: it can be set for Remote Setting, Arm/ Disarm of the

system on the mode of Multi-user. It should be set to be 4 digits of “

0000-9999”.

“Duress Code”: the duress pin is existed automatically by pulsing

number “1” with the last number of master ’s Code or User ’s Code. If the

last number is “9”, the last number of Duress Code is “0”. The other front

numbers are the same. For example: the master ’s Code is 1239. The

Duress Code will be 1230.

The format is: in the status of Code setting, input New Code OK

New Code OK

[ ] + [ ] + [

] + [ ] .

38 39

Page 23: Ks 868 e-users_manual of home security devices

(Note: the setting selection of Mono-user mode and Multi-user mode

can be referred on the item of “Report”.)

Note: The master ’s pin, 8 user ’s pin and dress’ pin can’t be set as

the same.

On the mode of Multi-user, set the User ’s Code of the

zone as 1357. The operation is as follow:

For example 1: 5th

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Set

Picture 3

Pin

1

Set

Picture 4

Pin

5

Set

Picture 5

3

!"

#$

Set

Pin

5

Picture 6

Step 1: In the program, and alarm panel

in working mode of Multi-user.

Press or to select Pin. When Pin

Menu flashes, press to enter.

Step 2: Press twice to enter “

User ’s Code”.

Step 3: When “1” is flashing, it means

the 1st User ’s Code. Press or to

reach “5”. Press to confirm and

input the New Code of 1357 OK

1357 again. The LCD screen

will show PASS if the set is successful.

[*] [#]

[OK]

[Set]

[*] [#]

[OK]

[ ] + [ ] & [

] + [OK]

For example 2: Set the master ’s pin as 1111, the operation as follows:

Step 1. In the program, and alarm panel in working mode of Multi-user.

Press or to select Pin. When Pin menu flash, press to enter.

Step 2: Press to enter “master ’s Code”.

Step 3: input the New Code of 1111 1111 again.

The LCD screen will show PASS if the set is successful.

[*] [#] [OK]

[Set]

[ ] + [OK] & [ ] + [OK]

4.9 How to set delay

4.9.1 Alarm Delay

For example 1:

There are sub-menus in Delay. As follows

1 for alarm delay

2 for arm delay

3 for siren duration

4 for ringing times

5 for circulated dialing times

6 for timer communication

The Alarm Delay is the time range that is from the alarm trigger to the

alarm activate.

The time range: 000 255s. If Alarm Delay time is “000”, that means

alarm at once.

Set the Alarm Delay to be 20s.

Pin

Picture 1

40 41

Page 24: Ks 868 e-users_manual of home security devices

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

1

Delay

Set

Picture 3

1

Delay

Set

Picture 3

221

Set

Delay

Picture 4

Step 1: In program, press or to

choose “Delay”, when the Delay Menu

flashes, then press to enter.

Step 2: “1” is for Alarm Delay, when “1”

flashes, press to confirm.

Step 3: press to set the

Alarm Delay. If the set is successful,

the LCD screen will show PASS.

[*] [#]

[OK]

[OK]

[020] + [OK]

4.9.2 Arm Delay

For example 1:

Arm Delay is the time range from Armed by users to the arm activation.

The time range: 000 255s. “000” mean Arm activate at once.

Set the Arm Delay to be 30s.

Pin

Picture 1

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

1

Set

Delay

Picture 3

2

Set

Delay

Picture 4

2

Set

Delay

Picture 5

3

!"

#$

Set

Delay

2

Picture 6

Step 1: In program, press or to

choose “Delay”, when Delay Menu

flashes, then press to enter.

Step 2: Press or to choose “2”. “

2” is for Arm Delay , when “2” flashes,

press to enter.

Step 3: Press to set the

Arm Delay. If the set is successful,

the LCD screen will show PASS.

[*] [#]

[OK]

[*] [#]

[OK]

[030] + [OK]

4.9.3 Siren duration

For example 1:

The range of siren duration is 01-99 minutes. It should be 2 digits.

set the alarm sound time as 30 minutes. The operation

is as follow:

Pin

Picture 1

42 43

Page 25: Ks 868 e-users_manual of home security devices

1

Set

Delay

Picture 3

3

Set

Delay

3

Set

Delay

3

!"

#$

Set

Delay

3

Picture 4

Picture 5

Picture 6

Step 1: In program, press or to

choose “Delay”, when Delay menu

flashes, then press to enter.

Step 2: Press or to

select “3”. “3” is for Alarm sound time.

When “3” flashes, press to enter.

Step 3: Press to set the

Alarm sound time. If the set is

successful, the LCD screen will

show PASS.

[*] [#]

[OK]

[*] [#]

[OK]

[30] + [OK]

4.9.4 Set ringing times

For example 1:

Dial the phone when the alarm connected, if the times of ring arrives

that users set, the alarm system will enter the remote set automatically.

The ring times range is 03-15 times. It should be 2 figures.

Set the ring times to be 10 times.

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Picture 1

1

Set

Delay

Picture 3

4

Set

Delay

Picture 4

4

Set

Delay

Picture 5

3

!"

#$

Set

Delay

4

Picture 6

Step 1: In program, press or to

choose “Delay”. When the Delay Menu

flashes, press to enter.

Step 2. Users can see “1” is flashing

and press or to choose “4”. “4”

is for ring time, press to confirm

Step 3. Press to set the

ring time

Note:

* The ringing times are suggested to be set more times, otherwise it may a

ffect the daily use.

* It is suggested to set the ringing times to be more than 5 times. If users

not used remote set, the ringing times can be set to be 15 times.

[*] [#]

[OK]

[*] [#]

[OK]

[10] + [OK]

4.9.5 Set dialing time

For example 1:

The range of dialing times is 03-15. The number shall be 2 figures.

Set the dialing times to be 10 times.

44 45

Page 26: Ks 868 e-users_manual of home security devices

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2 Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Picture 1

Pin

Picture 1

1

Set

Delay

Picture 3

5

Set

Delay

Picture 4

5

Set

Delay

Picture 5

3

!"

#$

Set

Delay

5

Picture 6

Step 1. In Program, press or to

choose “Delay”. When Delay Menu

flashes, press to enter.

Step 2: users can see “1” is flashing

and press or to choose “5”. “5”

is for ring time. Press to confirm.

Step 3. Press to set the

ring times. If the set is successful,

the LCD screen will show PASS.

[*] [#]

[OK]

[*] [#]

[OK]

[10] + [OK]

4.9.6 Timer Communication

The timer communication is the communication between alarm panel

and alarm center or users by telephone regular time. The range is: 00-

99hours. The time of Timer communication is counted when power on.

‘00’ is to off the Timer communication.

Note: the Timer Communication would be re-counted once power off.

set the timer communication to be 24 hours for alarm

panel and alarm center.

For example:

1

Set

Delay

Picture 3

6

Set

Delay

Picture 4

6

Set

Delay

Picture 5

3

!"

#$

Set

Delay

6

Picture 6

Step 1. In the program, press or

to select Delay. When Delay Menu

flashes, press to enter.

Step 2: when “1” flashes, press or

to choose “6”. “6” is for Timer

communication. Press to confirm

Step 3: Press to set the

Timer Communication. If the set is

successful, the LCD screen will

show PASS.

[*] [#]

[OK]

[*] [

OK]

[OK]

[24] + [OK]

46 47

Page 27: Ks 868 e-users_manual of home security devices

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Picture 1

Pin

Picture 1

4.10 How to set Repor

For example 1:

t

There are sub-menus in Report. As follows:

1 for Working mode of alarm system (mono-user/multi-users),

2 for Relay Report,

3 for remote switch by alarm center

4 for Compulsory Arm Switch

4.10.1 How to select working mode of alarm panel

There are two modes for option: Mono-user and Multi-user.

ON for mono-users, OFF for multi-user.

In the mode of Mono-user: set Away Arm and Home Arm of the system

In the mode of Multi-user: 8 users can set by their corresponding remote

controller and user ’s code. Each remote controller can Arm/ Disarm its

corresponding user independently.

Set the mode of the system as Mono-user mode. The

operation is as follow:

Set

Report1

Picture 3

Set

Report1

Picture 4

3

!"

#$

Set

1Report

Picture 5

Step 1: In program, Press or to

choose “Report”. When Report Menu

flashes, press to enter.

Step 2: “1” is for set the working mode

of panel., when “1” flashes, press

to enter.

Step 3: Press or to choose “

ON” or “OFF”. ON for mono-users,

OFF for multi-user.

[*] [#]

[OK]

[OK]

[*] [OK]

Step 4. Choose the ON, and press

to confirm. If the set is successful,

the LCD screen with show PASS.

[OK]

4.10.2 Relay Report

Users can set ON/OFF for integrated devices when alarm status change (

like arm, disarm or alarm).The information is listed as follows:

Indications Alarm

Siren

Alarm Light

Warning Sign

activate

Light

Red lightflash quickly

Arm

A “Di”

Flash once

Green light flashonce per 5s

Disarm

Flash twice

Red light flashonce per 5s

Red light flashonce per 5s

IntegratedDevices

For example 1: Turn on “Relay Report”

Step 1: In program, Press or to

choose “Report”. When “report”

Menu flashes, press to enter.

[*] [#]

[OK]

48 49

Page 28: Ks 868 e-users_manual of home security devices

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Picture 1

Set

Report1

Set

Report2

Set

Report2

3

!"

#$

Set

Telephone

2Report

Step 2: “2” is for Relay report ON/OFF,

press or to choose “2” when “2”

flashes, press to enter.

Step 3: press or to choose “ON”

or “OFF”.

Step 4. choose the ON, and press

to confirm. If the set is successful, the

LCD screen with show PASS.

[*] [#]

[OK]

[*] [#]

[OK]

4.10.3 Remote Switch by alarm center

For example 1:

“ON” is to tune on, OFF is to turn off the remote switch by alarm center.

Note: the alarm center shall be assigned by factory.

the alarm unit allows to be controlled remotely. The

operation is as follow:

Set

Report1

Picture 3

Set

Report3

Picture 4Set

Report3

Picture 5

3

!"

#$

Set

Telephone

3Report

Picture 6

Step 1: In program, press or to

choose “Report”. When “report” Menu

flashes, press to enter.

Step 2: When “1” is flashing, press

or to reach “3”. Press to enter,

press to choose “ON”. Then press

again to make confirmation.

[*] [#]

[OK]

[*]

[#] [OK]

[*] [

OK]

4.10.4 Compulsory Arm switch

“ON” is to tune on, OFF is to turn off the switch.

Compulsory Arm: when wired zone is in trouble, it allows the user Arm

this zone. The system will Bypass the troubled zone automatically. Once

the troubled zone restores, this zone will enter the status of Arm.

Un-compulsory Arm: when wired zone is in trouble, it doesn’t allow the

user Arm this zone. The zone’s trouble should be deleted at first, then it

can be Armed again.

Picture 6

Picture 5

Picture 5

Picture 5

50 51

Page 29: Ks 868 e-users_manual of home security devices

Note: If Compulsory Arm is activated, the troubled zones still exist in

arm status.

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Picture 1

Pin

Picture 1

Set

Report1

Picture 3

Set

Report4

Picture 4

Set

Report4

Picture 5

3

!"

#$

Set

4Report

Picture 6

For example 1: the alarm unit allows to Compulsory Arm. The operation

is as follow:

Step 1: In program, press or to

choose “Report”. When “Report” Menu

flashes, press to enter.

Step 2: When “1” is flashing, press

or to reach “4” is for Compulsory

Arm ON/OFF, press to enter.

press to choose “ON”. Then press

again to make confirmation.

[*] [#]

[OK]

[*]

[#]

[OK]

[*] [

OK]

4.11 How to make enrollment

There are sub-menus in Enrollment. As follows,

1 is for 1-16 zones detectors enrollment

2 is for 1- 8 remote controllers enrollment

The standard kit has collocated wireless accessories (such as wireless

door sensor, detector and remote controller) when they are ex-factory.

If the users need to add additional detectors or remote controllers, the

operation as follows:

Note:

4.11.1 Enroll detectors

For example 1:

In the process of enrolling, a long “Di” is to alert users that the

detector has been existed in alarm system, the repeated enrol is not

allowed.

The system supports 16 wireless zones and each zone can enroll 3

detectors.

In the zone menu, 1 for detector, 2 for detector, 3 for detector

of this zone

Users can trigger the detector to send the signal by power switch,

tamper switch or trigger PIR.

Enroll with the detectors of the detector on the zone.

1 2 3

1 2

st nd rd

st nd

Step 1: In program, press or to

choose “Enroll”. When Enroll menu

flashes, press to enter.

[*] [#]

[OK]

52 53

Page 30: Ks 868 e-users_manual of home security devices

Step 2: Press or to choose “1”. “

1” is for Enroll Detectors, when “1”

flashes,press to enter.

Step 3: Press or toreach “2”. “2”

is for the 2nd zone. Press to

confirm

Step 4. Trigger detector. Once

the alarm system receives the

signal, the LCD screen will

show the code of detector. That

means the set is successful

[*] [#]

[OK]

[*] [#]

[OK]

1

Set

Zone

Enroll

Picture 3

Set

Zone

Enroll

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

Picture 4

Set

Zone

Enroll

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

Picture 5

21 3

Picture 6

Set

Zone

Enroll

21 3

Picture 7

Set

Zone

Enroll

4.11.2 Delete the enrolled detectors

4.11.3 Enroll remote controllers

For example 1: Delete the enrolled detector of the detector on the

zone. Please repeat the operation of Step 1-3 on 4.11.1. Then set as

follow:

Press twice. If the LCD screen show as Picture, the deletion is

successful.

[OK]

1 2st nd

The system supports 8 remote controllers and each remote controller

corresponds with the 8 users or main user.

Enroll of remote controller in number.For example 1: 5th

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Pin

Picture 1

1 2 3 4 5 6 7 8

Set

Enroll

1

Set

Zone

Enroll

Picture 3

Picture 4

1 2 3 4 5 6 7 8

Set

Enroll

Picture 5

5

Set

Enroll

1 2 3 4 5 6 7 8

Picture 6

Step 1: In program, press or to

reach “Enroll”. When Enroll Menu

flashes, press to enter.

Step 2: Press or to choose “2”. “

2” is for remote controller program,

when “2” flashes, press to enter.

Step 3: Press or to choose “5”. “5”

is for the remote controller. Press

to enter

Step 4. Trigger any key of remote

controller to remit. Once the alarm

system receives the signal, the LCD

screen will show the code of remote

controller, it means the set is

successful

[*] [OK]

[OK]

[*] [#]

[OK]

[*] [#]

[

OK]

5th

54 55

Page 31: Ks 868 e-users_manual of home security devices

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2

Set

Telephone

Clock

Timer

Zone

Attribute

Pin

Delay Record/ Playback

Siren

Enroll

Report

Picture 2Pin

Picture 1

Pin

Picture 1

4.11.4 Delete the enrolled remote controller

For example 1: Delete the enrolled detector of the 5th remote controller.

Please repeat the operation of Step 1-3 on 4.11.3. Then set as follow:

5

Set

Enroll

1 2 3 4 5 6 7 8

Picture 1

Set

Enroll

1 2 3 4 5 6 7 8

Picture 2

Press twice. If the LCD screen

show as Picture, the deletion

is successful.

[OK]

4.12 Wireless siren code

For example 1:

The “siren” menu is to enroll the code of wireless siren. The wireless

siren code should be as 8 digits quaternary.

The wireless siren output shall refer to 4.7 attributes.

Set wireless siren code as “12332100”. The

operation is as follow:

Set

Siren1

Picture 5

3

!"

#$

Set

Siren

1

Picture 6

1

Set

Siren

Picture 3

Step 1: In program, press or to

reach “Siren”, when the Siren Menu

flashes, Press to enter.

[*] [#]

[OK]

Step 2. Press 12332100 to set

the wireless siren code. And press

again to make confirmation. If the set is

successful, the LCD will show PASS.

[OK] + [ ]

[OK]

4.13 Voice Record

The system supports 20s Voice Record to record the alarm information

by users. The operation is as follows:

2

Set

Record/ Playback

1

Set

Record/ Playback

Picture 3

Picture 4

Step 1. In program, press or to

reach “Rec/Play”. When “Rec/Play”

Menu flashes, press to enter.

Step 2. Press or to reach “2” , “

2” is for record new voice, press

to start to record. The voice is not

beyond 20 seconds, press to

finish the voice record.

[*] [OK]

[OK]

[*] [#]

[OK]

[OK]

56 57

Page 32: Ks 868 e-users_manual of home security devices

Step 3: After finishing record, “2” is

flashing. Press or toreach “1” ,

and press toplayback the

recorded voice.

1. It is suggested to playback

and check the new record. Rerecord

the voice once unsatisfied.

2. In order to prolong the ringing time

when receiving the alarm phone,

the record voice should be

considered to extend.

[*] [#]

[OK]

Note:

2

Set

Record/ Playback

Picture 5

1

Set

Record/ Playback

Picture 6

1

Set

Record/ Playback

Picture 6

4.14 Factory default

ZoneMono-user mode

Multi-user mode

Away Zones List ofmain user

Home Zones Listof main user

Away Zones List ofthe 1st-8th users

01020304050607080910111213141516

01020304050607080910111213141516

01020304050607080910111213141516

Attribute

Main unit

16 zones 110/ burglar

110

No. Programming Items Factory Default

1 Phone

8 groups of phones

8 groups of Alarm Report

8 groups of Zones List

Blank

ON

01020304050607080910111213141516

8 groups of Arm/ Disarm Report OFF

8 groups of Self-inspection Report OFF

Clock2

3

4

5

Timer

Mono-user mode2 groups of TimerArm/ DisarmDisarm Blank

BlankMulti-user mode

2 groups of TimerArm/ Disarm

2 groups of user ’sZones List

0102030405060708

Playback

Record00

6 Code

Mono-user

Multi-user

Installer's Code

Master's Code

Installer ’s Code

Master's Code

User's Code

000000

000000

1234

1234

Blank

7 Delay

Delay Alarm

Delay Arm

Alarm Sound Time

Ringing Times

Dialing Times

Timer Communications

000 (No delay)

000 (No delay)

05

05

03

00 (No communication)

8 Report

System Mode

Relay Report

Remote Controlling Switch

Compulsory Arm Switch

OFF (Multi-user mode)

OFF

OFF

OFF

9 Enroll

Enroll detectors

Enroll remote controllers

Blank

Two remote controllers

Siren Wireless siren code 00000000

11VoiceRecord/Playback

10

4.15 Installer set

A)Recover the installer’s code to be factory default (000000).

Installer code is 12*48#.

In Installer Set menu, 1 is for “Recover installer ’s code”. 2 is for

“recover the factory default”

Picture 1

Step 1: In standby, Press [12*48# ] + [

OK]

58 59

Page 33: Ks 868 e-users_manual of home security devices

1

Picture 2

1

Picture 3

Step 2: Users can see “1” flashing.

Press to recover the installer ’s

code to factory default (000000).

If the set is successful, The LCD

screen will show PASS.

[OK]

B) Recover the factory default

Picture 1

1

Picture 2

2

Picture 3

2

Picture 4

2

Picture 5

Step 1: In standby, Press 12*48#

Step 2: Users can see “1” flash. Press

or to reach “2”. When “2” flashes,

press to delete all setting to

factory default. If the set is successful,

the LCD screen will show PASS.

Please don’t operate the

other items haven’t been

mentioned on the manual without

permission.

[ ] + [

OK]

[

*] [#]

[OK]

Note:

Ⅴ Technology Parameter

Maintenance

Size: 264.2 X 179.6 X 47.6 mm (L*W*H), error ±1mm

Power: AC220V DC13.8V 500mA

Wireless distance: (PIR to unit) 300m

Wireless frequency: 433.92MHz:

AUX output current: 80mA

150mA (with GSM)

Wireless modulation: OOK

Assistant Power: DC12V 150mA

Alarm decibel: 90dB ( Max & Within 1m)

Working environment: Working Temperature: -10℃ 55℃

Relative Humidity: 10% 80%

It is suggested to test the system per one month to make sure the

normal working of the system.

Please take cotton cloth or sponges with water to clean the alarm unit.

Note: Don’t use anything with organic solvents to clean the system,

such as coil oil, superglue, etc. Lest should destroy the system.

5.1 Alarm unit

6.1 Regular test

6.2 Clean the alarm unit

~+

Ⅶ Exclude the Simple Troubles

Low-battery on is reported fromone zone.

The battery is of low power. Change the detector ’s battery.

Wrong alarm of wirelessdetector in usual

The installation positionis wrong.

Battery is of low power.Indicator flashes onceper 5s.

Re-install the detector.

Change the battery.

Situations Reasons Solutions

Press the remote controller butwithout enlightened indicator. Orthe distance of remote controller istoo close.

Low power of the remotecontroller.

Change the battery of the remotecontroller.

60 61

Page 34: Ks 868 e-users_manual of home security devices

Check whether the anode &cathode of power wire and signalterminal are connected right ornot; check whether the terminal istightened up or not.

Connect with 2.2K sewingresistance as the manualinstruction.

Wrong connection ordefect touch.

Wrong connection withsewing resistance.

The wired zone doesn’t makealarm or alarm wrong whentriggered.

The system can’t dial the alarmphones when the extensionphone was received.

Check whether there iswrong connectionbetween the phone lineand local calls line.

Change the position betweenthem.

When the alarm system is instandby status, the systemdidn’t indicate with line-cut.

Test whether line-cut isON or not.

Turn “Test for line-cut” to ON asmanual instruction.

The clock can’t work normally.

The button battery ofthe unit is destroyed.

The crystal of clockchip isn’t activated.

Change the button battery

Re-set the time of system.

“Burglar” and “Perimeter”zones can not make alarm bytriggering in Arm status.

The zone list is not setcorrect.

Re-set the zone list.

There is no alarm on-site, whenthe alarm system is makingalarm.

1.The system was set tobe Mute alarm;2.The zone attributewas defined as“Duress”.

Re-set the system according tothe setting of manual.

The wireless siren can not makealarm in gear, when the alarmsystem is making alarm.

1.The address code ofsiren was set to bewrong.2.The function of Sirenwas not ON.

Re-set the system according tothe setting of manual.

It can’t be Armed.The wired zone is introuble.

Restore the wired zone or turn oncompulsory Arm.

3 Intruders may gain access through unprotected openings or have the

technical sophistication to bypass an alarm sensor or disconnect an

alarm warning device. Passive Infrared Motion Detectors can only

detect intrusion within the designed ranges as diagrammed in their

installation manual. They do not provide volumetric area protection.

They can not detect motion or intrusion that takes place behind walls,

ceiling, floors, closed doors, glass partitions, glass doors, or windows.

4 Passive Infrared Detector sense changes in temperature; however,

as the ambient temperature of protected area approaches the

temperature range of to , the detection performance will

decrease.

5 It is exiting no-power or battery-aging.

6 Alarm warning devices such as sirens, bells or horns may not alert

people or wake up sleeper if they are located on the other side of closed

or partly open doors.

7 Phone lines needed to transmit alarm signals from a premise to a

central monitoring station may be out of service or temporarily out of

service. Phone lines are also subject to compromise by sophisticated

intruders.

8 The most common cause of an alarm system not functioning when an

intrusion or fire occurs is inadequate maintenance. This alarm system

should be tested weekly to make sure all sensors and transmitters are

working properly.

9 The wireless communication distance is the testing figure in open

area. Please make sure no obstacle in the surrounding environment to

guarantee the reliability of the wireless communication distance

farther.

30 40℃ ℃

Ⅷ The limitation of this alarm system

While this system is an advanced design security system, it does not

offer guaranteed protection against burglar or fire or other emergency.

Any alarm systems, whether commercial or residential, is subject to

compromise or failure to warn for variety of reasons. For example:

1 Owing to the omission of the user, the system wasn’t Armed.

2 Misunderstanding on the user ’s manual by the user or installer

causes the abnormal working of the system.

62 63

Page 35: Ks 868 e-users_manual of home security devices

10 If you disagree with the above mentioned items, please return the

alarm system to our company within 3 days from purchasing. Installing

an alarm system may make one eligible for lower insurance rates, but

an alarm system is not a substitute for insurance. Homeowners,

property owners and renters should continue to act prudently

themselves and continue to insure their lives and property.

64