Network Intelligent Alarm System
User’s Manual
V1.0P/N:350310000868E010
Attachment List
Please check the complete attachment in the package before your
making installation and setting.
Directory
1.1 Brief introduction
1.2 Unit introduction
1.3 Spares specification
1.4 Sketch diagram of system running
2.1 Sketch diagram of the back of alarm unit
2.2 Wall-mounting installation
2.3 Sketch diagram of connecting interface
2.4 Wired detectors installation
2.5 Interface of alarm output
2.6 Enroll wireless detectors
3.1 Specification of beep
3.2 Arm/ Disarm
3.3 Alarm & alarm process
3.4 Remote operation
3.5 Events logs & Query
4.1 Index table of setting
4.2 Operation specification
4.3 How to set phone/CID
4.4 How to set Date
4.5 Arm/ Disarm Timer
4.6 Zone List
4.7 Zone Attributes
4.8 Modify pin
4.9 How to set delay
Summary
Installation & Connection
Operation Manual
How to set
Ⅰ
Ⅱ
Ⅲ
Ⅳ (14)
(14)
(19)
(19)
(30)
(31)
(34)
(36)
(39)
(41)
(9)
(9)
(9)
(10)
(13)
(13)
(1)
(1)
(3)
(4)
(5)
(5)
(5)
(6)
(7)
(7)
(8)
(8)1pc
2pcs
4pcs
4pcs
1pc
4pcs
1pc
1pc
1pc
1pc
1pc
1pc
1pc
2pcs
4pcs
4pcs
1pc
4pcs
1pc
1pc
1pc
1pc
1pc
1.Alarm System (433SF-1)
Alarm Unit (433SF)
Wireless Remote Controllers
2.2K Sewing Resistances
M4 45Screws
M3 8Screws
Stopper
6 code connector base
3 code connector base
User’s Manual
Phone Line
Adapter
Alarm Unit (433SF/GSM/S)
Wireless Remote Controllers
2.2K Sewing Resistances
M4 45Screws
M3 8Screws
Stopper
6 code connector base
3 code connector base
User’s Manual
Phone Line
Adapter
12V 1300mAh NI-MH battery
2.GSM Alarm System (433SF/GSM/S-1)
4.10 How to set Report
4.11 How to make enrollment
4.12 How to enroll wireless siren pin
4.13 Voice Record
4.14 Factory default
4.15 Installer Set
5.1 Alarm unit
6.1 Regular test
6.2 Clean the alarm unit
Technology Parameter
Maintenance
Exclude the Simple Troubles
The limitation of this alarm system
Ⅴ
Ⅵ
Ⅶ
Ⅷ
(61)
(61)
(61)
(61)
(61)
(48)
(53)
(56)
(57)
(58)
(59)
Foreword
Appreciate for your choosing this alarm system, which is reliable for its
certificates and multifunction.
It adopts the most advanced technology of digital sensor and
controlling. It is a kind of intelligent alarm control system, aggregated
with the features of Burglar, Anti-fire, Anti-gas, etc. Compatible with
CONTACT ID agreement enables the alarm system expanded usage
and stronger compatibility. With the excellent appearance and
powerful function, it can be widely used at home, community, financial
office and office building, etc.
To make sure the normal usage, please read the user’s manual before
your operation. Our company retains the right to modify and explain the
User’s Manual. Moreover, modified specification won’t be informed
specially.
Ⅰ Summary
1.1 Brief Introduction
1. LCD interface: English LCD screen, easy operation, working
running and alarm procure are of easy and simple usage.
2. Built-in antenna and latest design.
3. 16 wireless zones: 1-16 wireless zones. Each zone can enroll 3
detectors. Be compatible with the wireless detectors from our
company and easy to expand the wireless zones.
4. 4 wired zones: 13-16 wired zones. Act on NO/ NC alarm by
connecting with end-of-line resistor. It owns the functions of clew
for wired zones’ trouble and compelling Arm.
5. The modes of Multi-user and Mono-user can be exchanged. On
the mode of Multi-user, 8 remote controllers: 8 remote controllers
are assigned to 8 users. CID alarm center can identify the different
users by the pin of remote controllers; On the mode of Mono-user,
the user can Away Arm/ Home Arm the whole system.
6. 8 remote controllers: on the mode of Mono-user, 8 remote
controllers share 1 main user; on the mode of Multi-user, 8 remote
controllers refer to 8 users and the alarm center can distinguish
the directions from different users.
7. 8 alarm phone numbers can be set for users or CID.
8. Zone attributes can be set according to the attributes of the alarm
unit and 16 wireless zones. On-spot Alarm, linkage output and
wireless siren are for option. Individually setting to each zone is
also enabled. Zone attributes: 7 attributes are Burglar, Perimeter,
Duress, Panic, Fire, Gas and Medical.
9. Easy enrollment: Wireless detector, remote controller can be
enrolled with the alarm system automatically. Each zone / remote
controller can be enrolled and delete enrollment automatically &
independently.
1
(61)
(62)
10. 20s voice record: Record / Playback are easy. 20s record can
be re-recorded at freedom.
11. The pin management: 1 installer ’s pin, 1 master’s pin, 8 users’
pins and Duress pin (the Duress pin is plus “1” to the last number
of master’s pin or user’s pin) (8 groups of user’s pins are valid on
the mode of Multi-user only).
12. Two groups of Timer Arm/ Disarm: to make two groups of Timer Arm/
Disarm according to the working day and resting day. Each group of
Timer Arm/ Disarm has a regular time to be set (Each group of Timer
Arm/ Disarm refers to one user on the mode of Multi-user).
13. Queried: It can record and query the 30 logs of alarm, including Away
Arm, Home Arm, Disarm, Line-cut, Zone Arm, Zone Disarm, low-power
of Zone, the alarm time and the alarmed zone.
14. Support alarm report, the zone list of alarm phone, Arm/ Disarm
information and report for Self-testing.
15. Communication time can be set as 00-99 hours. It supports the alarm
unit and alarm center, timer communication with the related user.
16. Delaying Alarm/ Arm time can be set as 000-255 seconds,
17. The alarm sound duration can be adjusted as 01-99 minutes.
18. Circulated dialing times and ringing times can be adjusted as 03-15 times.
19. Siren: the unit has equipped with inner siren. Meanwhile, it can connect
with wired siren in wire terminal and program with wireless siren
20. Three levels of alarm volume are optional.
21. Alarm line-cut: If the line of wired detector is cut, the alarm system will
make alarm at once. Meanwhile, if the phone line is cut, the unit will send
the warning tone.
22. NO and NC relay alarm output are suffered. Also 12V 150mA AC is
provided.
23. Remote operation: It can make the following actions by phone remotely,
such as Arm/ Disarm, monitor indoor, turn on-site alarm on the remote
phone.
24. GSM + PSTN alarm. The user can choose GSM wireless alarm or GSM
wireless with PSTN wired alarm together.
25. AC/ DC: Ext 220V voltage and inner with rechargeable batteries.
1.2 Unit introduction
Set Query Reset OK
1 23
4 5 6
7 8 9
0* #
LCD display
Horn
MIC
IndicatorDC Arm Alarm PSTN GSM
Picture 1 Sketch diagram of unit
Picture 2 LCD View
Picture 3 Sketch diagram in standby
2 3
Set Query Reset OK
1 23
4 5 6
7 8 9
0* #
DC Arm Alarm PSTN GSM
1.4 Sketch diagram of system running
Ⅱ Installation & Connection
The phone line and connection wires of wired zones can be connected
by hiding on the back of the alarm unit. The alarm unit can be installed
wall-mounted or on the desk. It can be installed without opening the
cover. It has advantage of simple installation and safety.
2.1 Sketch diagram of the back of alarm unit
1.3Spares specification
DC” indicator
When DC supplied, the indicator is on.
When AC supplied, the indicator is off.
Arm” indicator
A)In Away Arm or Home Arm, the indicator will be on.
B)In Arm delay, the indicator will flash once per 2 seconds.
C)In Disarm, the indicator will be off.
Alarm” indicator: It is on, when making alarm. And vice versa.
PSTN” indicator
GSM” indicator:
A) ON: the GSM signal is normal.
B) Flash: the GSM signal is weak.
C) OFF: the GSM signal is in trouble or not existing, it will influence
the usage of GSM.
Note: if the GSM indicator is OFF after inserting for 3 minutes, the user
should check whether GSM module is connected well or not.
Function keys:
Press in standby status and input the correct user’s
pin to enter the program.
Query Press Query in standby status. The logs can be
inquired.
Reset Delete the previous inputted or exit to previous status.
OK Confirm what users inputted
Number key: Be used to set and Arm/ Disarm.
“
“
③ “
④ “
⑤ “
⑥
:
:
:
:
⑦
①
②
[Set] [Set]
[ ] [ ]
[ ]
[ ]
,-
.$
/0
*Yes
#No0
!" #$ %&' ()'
1*+ 2*+ 3*+ 4*+ 5*+ 6*+ 7*+ 8*+
Picture 1Wiring slot
Battery case
Wiring terminal
Tamper switch
4 5
2.2 Wall-mounting installation 2.3 Sketch diagram of connecting interface
2.4 Wired detectors installation
Wired zones adopt AD converting technology and can be connected with
2.2K end-of-line resistor, which make sure the reliability of alarm system.
The power of wired detector was suffered by 12V output terminal of alarm
system. The output terminal of every detector connects with the connection
and GND of the corresponding zone by end-of-line resistor as picture
showing:
80mm 80mm
10
5m
m
Under mounting hole
Upper mounting hole
Picture 2
Picture 3
M4x45
Picture 4
M3x8
1) Take the hang-up board from the back of the alarm unit, and fix four
plugs and one M4 45 screws on the wall accordingly (as Picture 2).
2) Draw the one set of 6 pin Wired Holder and two sets of 3 pin Wired
Holders. Connect with power and wired zones, etc. Then insert the
related Wired Pillar and Phone Line. Hang the alarm unit on the screws
as pictures 6 and Picture 7.
3) After finishing connecting, pull the three holes of the back of alarm
unit up the related holes of hang-up board (as Picture 3).
4) Tighten the bottom of hang-up board with the back of alarm unit by
M3 8 screw (as Picture 4).
×
×
Picture 5
K2 OFFON
Line-cut test switch( )
( )
OFF
On
LINEPHONE
Phone
Phone connection
Volume: L-HK1 OFFON
Battery switch( )
( )
OFF
On
SW1
Note:
The power of detector suffered by the alarm system should not more
than 12V power (or 150mA). Otherwise, it should be suffered with 12V
backup power EXT.
When there are not wired zones connected, the wired zones should
also be connect with end-of-line resistor to make sure the alarm system
working normally.
①
②
≤
6 7
1.NO connection: The output terminal adopts paralleled connection
between end-of-line resistor and NO output detector.
2.NC connection: The output terminal adopts tandem connection
between end-of-line resistor and NC output detector.
3.Integrated connection: When there are NO output detector and NC
output detector, it can adopt integrated connection. The ways of
connection are showed as Picture a & Picture b:
2.5 Interface of alarm output
1. This interface is to connect the wired
siren or alarm light, etc. The way of
connection is showed as Picture c.
2. The connection loading is 1A 120V AC/
1A 24V DC, when the loading of
controlled circuit is too large, it should be
suffered with power independently to avoid destroying the alarm
system. Please visit Picture d:
2.6 Enroll wireless detectors
1.Install the enrolled detectors in the effective range from alarm system
as the user’s manual of wireless detector describing. Make sure to test
for the detector and the alarm system.
2.Wireless transmitting function: The alarm system may not receive the
signal from wireless detectors due to far distance or wall-shading
between wireless detector and alarm system, the wireless repeater from
our company can be chosen to lengthen the transmitting distance.
Ⅲ Operation Manual
3.1 Specification of beep
3.2 Arm/ Disarm
On the mode of
Multi-user, 1-8 remote controllers are corresponded to 1-8 users.
On the mode of Mono-user, 1-8 remote controllers are corresponded to
1 user. If the alarm systems connect with CONTACT ID, the alarm center
will record every master by its corresponding user. It is convenient to query.
3.2.1 Armed/ Disarmed by the remote controller.
3.2.2 Shortcut of Arm/ Disarm in alarm unit
On the mode of Mono-user:
Away Arm shortcut:A) In Disarm status, press “4” until hearing beep of
“Di”. Then release it. Input the master’s/user’s pin and on the
interface of entering. If the pin input is correct, the system will enter a
status of Away Arm. (When Delay Arm of the system was set to be 0s)
[OK]
B) In Disarm status, press “4” until hearing beep of
“Di”. Then release it. Input the master’s/user’s + and on the
interface of entering. If the pin input is correct, the system will enter a
status of Home Arm. (When Delay Arm of the system was set to be 0s)
Home Arm shortcut:
[#] [OK]
A short “Di” Arm
Two short “Di” Disarm
A short “Di” per 1s Delay Arm
Two quick short “Di… Di” per 1s Alarm Delay
A long “Di” per 15s Low power
Three quick short “Di…Di…Di” per 1s Phone line-cut
8 9
Set Query Reset OK
1 23
4 5 6
7 8 9
0* #
DC Arm Alarm PSTN GSM
Set Query Reset OK
1 23
4 5 6
7 8 9
0* #
DC Arm Alarm PSTN GSM
C)Disarm shortcut: In Arm or Alarm status, press “4” until hearing beep
of “Di”. Then release it. You are required to input the master ’s/user ’s and
OK Input the correct pin and OK and the system enters Disarm status.「 」.
On the mode of Multi-user:
Away Arm shortcut:
Disarm shortcut:
A) In Disarm status, press “4” until hearing beep
of “Di”. Then release it. Input the corresponding master ’s/user ’s and
OK on the interface of entering. If the pin input is correct, the system
will enter a status of Away Arm. (When Delay Arm of the system was set
to be 0s)
B) In Arm or Alarm status, press “4” until hearing beep
of “Di”. Then release it. You are required to input the corresponding
master ’s/user ’s and OK Input the correct user ’s pin, the system
enters Disarm status.
Note: The pins are referred on Term of 4.8.
「
」
「 」.
3.2.3 Timer Arm/ Disarm
3.2.4 Remote Arm/ Disarm
Set Timer for Arm or Disarm accordingly. When the system runs to the
setting time, it will enter Away Arm/ Disarm automatically. (On the mode
of Multi-user, each group of Timer Arm/ Disarm is corresponded to one user.)
1) Remote Arm/ Disarm on phone
Please refer to Term of 3.4 remote operation.
2) Remote Arm/ Disarm on GSM (GSM module should be equiped)
Please refer to the User ’s Manual of GSM Module
3.3 Alarm & alarm process
When the zone is set as “Burglar” or “Perimeter”, the intruding alarm
won’t be made except the alarm system is in the status of Arm. And it
will be influenced by Delay Alarm Time. But for the Panic alarm, such as
Tamper Alarm, it will not be influenced by Delay Alarm Time whatever the
status the alarm system is.
When the zone is set as “Panic”, “Fire”, “Gas” or “Medical” etc, the system
will make alarm once the zone is triggered.
“Duress” is for special situations, such as there is required to make alarm
silently on spot.
3.3.1 Alarm attributes
3.3.2 Alarm Phone
When the alarm system receives the signal from detectors, it will activate
alarm at once and dial the set phones. The user will hear the recorded
voice on the phone. In the end of record, you will hear “Di”. You can
operate the alarm system on the key of phone within 5s (as Picture 8).
If the alarm won’t process within 5s, the alarm dialer will go on. If this user
have valid operation through phone, the alarm system will continue to dial
next phone. And won’t dial this user ’s again.
Input “2#” to eliminate the alarm, the alarm system will continue to dial
other pre-set phones.
Picture 8
10 11
PS
TN
The alarm system sends the alarm signal to the alarm center; the center
will reply the alarm system with the confirmed signal. If receiving the
confirmed signal from the alarm center, it won’t dial alarm center again.
Or else, it will dial alarm center continually until the dial times arrives.
The alarm information is displayed and handled by the alarm center on
the computer.
3.3.3 The alarm center 3.4 Remote operation
The users can call the phone number that alarm unit connected to set
remotely. The user dials the phone number that alarm unit connected,
and waits for ring times arrives, the user will hear a DI, then have to input
the user ’s pin and #, if the user ’s pin corrects, you can set below..
3.5 Events logs & Query
Alarm, Away Arm, Home Arm, Disarm, phone
line-cut, Arm/ Disarm of detectors, Low voltage, battery restore, etc.
3.5.1 The alarm events are:
3.5.2 Query
Press Query in standby to inquiry the alarm logs (30 pieces at most).
If the total logs exceed 30 pieces, the oldest record will be deleted. Each
piece of record is signed as “nx” (“x” is the number of alarm logs).
Users can read the logs with pressing or
For example, when the alarm system is in standby status, you can
press to enter the query screen.
[ ]
[*] [#]
[Qurey]
.
3.3.4 The process of making alarm (Picture 9)
Picture 9Picture 1
Set Query Reset OK
1 23
4 5 6
7 8 9
0* #
DC Arm Alarm PSTN GSM
KS-868E (433.92MHz)
12 13
Picture 12
Picture 2
Press to display the specifications: 18:18 July 1st Wednesday,
the first zone makes Perimeter Alarm as follows as Picture 2:
press to read next one
[OK]
[#]
3.5.3 Trouble
When there is a trouble existing, the screen will display as Picture 3:
it means there is trouble on the wired zone.
Press to display which wired zone is in trouble.[#]
Picture 3
Disarm
Fault
Picture 4
13 14 15 16Fault
Ⅳ How to set
Please read the following manual carefully before your usage. It is
suggested to make operation under the professional person guidance.
Note: We are not responsible for the default caused by wrong operation.
4.1 Index table of setting
4.1.1 On the mode of Mono-use
Set
Phone
Set the phones
Report for alarm information
Set the phone zones list
Set Report for Arm/ Disarm
Set Report for self-testing
The 1 phone numberst
The 2 phone numberst
The 3 phone numberst
The 4 phone numberst
The 5 phone numberst
The 8 phone numberst
Clock
Timer
Arm for the 1 Timerst
Disarm for the 1 Timest
Arm for the 2 Timernd
Disarm for the 2 Timernd
Zone
Attribute
Away Arm zones list
Home Arm zones list
Set the attribute of the alarm unit
Alarm on-spot for option
Integrated alarm output for option
Wireless siren for option
01 zone attribute
02 zone attribute
Set the attributes of 16 zones
Alarm on-spot for option
Wireless siren for option
Integrated alarm output for option
Burglar
Perimeter
Duress
Panic
Fire
Gas
Medical
Code
Installer' pin
Master's pin
14 15
Delay
Set time of Delay Alarm
Set time of Delay Arm
Set time of Alarm sound
Set remote ringing times
Set the circulated dialing times of alarm receiving phones
Set time of Timer Communication
Report
System-setting modes for option
Mode of Mono-user
Mode of Multi-userRelay Report
Controlling switch of Alarm Center
Switch of compulsory Arm
Enrollment
Detector enroll
Enroll the detector of the1 zonest
Enroll the detector of the 2 zonend
Enroll the detector of the 16 zoneth
Enroll the 1 detectorst
Enroll the 2 detectornd
Enroll the 3 detectorrd
Enroll remote controller
Enroll the 1 remote controllerst
Enroll the 2 remote controllernd
Enroll the 8 remote controllerrd
Siren Code of wireless siren
Rec/ Play
Playback
Record
4.1.2 On the mode of Multi-user
Set
Phone
Set the phones
Report for alarm information
Set the phone zone list
The 1 phone numberst
The 2 phone numbernd
The 3 phone numberrd
The 4 phone numberth
The 5 phone numberth
The 8 phone numberth
Set Report for Arm/ Disarm
Set Report for self-testing
Clock
Timer
Arm for the 1 Timerst
Disarm for the 1 Timerst
Arm for the 2 Timernd
Disarm for the 2 Timernd
Set Arm/ Disarm Timer
Set zones list of the user
Zone
Away Arm zones list of the 1 userst
Away Arm zones list of the 2 usernd
Away Arm zones list of the 8 userth
Attribute
Set the attribute of the alarm unit
Alarm on-spot for option
Integrated alarm output for option
Wireless siren for option
01 zone attribute
02 zone attribute
Set the attributes of 16 zones
Alarm on-spot for option
Integrated alarm output for option
Wireless siren for option
Burglar
Users' list of the Timer Arm/ Disarm1st
Users' list of the Timer Arm/ Disarm2nd
Perimeter
Duress
Panic
Fire
Gas
Medical
16 17
Code
Installer' pin
Master's pin
Delay
Set time of Delay Alarm
Set time of Delay Arm
Set time of Alarm sound
Set remote ringing times
Set the circulated dialing times of alarm receiving phones
Set time of Timer Communication
Report
System-setting modes for option
ON:Mode of Mono-user
OFF:Mode of Multi-userRelay Report
Controlling switch of Alarm Center
Switch of compulsory Arm
EnrollmentDetector enroll
Enroll the detector of the1 zonest
Enroll the detector of the 2 zonend
Enroll the detector of the 16 zoneth
Enroll the 1 detectorst
Enroll the 2 detectornd
Enroll the 3 detectorrd
Enroll remote controller
Enroll the 1 remote controllerst
Enroll the 2 remote controllernd
Enroll the 3 remote controllerrd
User's pin
the user's pin1st
the user's pin2nd
the user's pin8th
Siren Address pin of wireless siren
Record/ Playback
Playback
Record
4.2 Operation specification
4.3 How to set phone/ CID
* It adopts Menu to guide the users. In the standby status, you can press
and the alarm unit will require to input the user ’s pin and OK.
If the user ’s pin input is wrong with three times continually, the alarm
will be activated for one minute. Any operations are not allowed during
that time. The alarm will be locked 1 minute. After one minute, the user
can press Disarm by remote controller to unlock the alarm system.
* Right operation with a short “Di”; Wrong operation with a long “Di”.
* The alarm system will exit the standby status, if there is no operation
within 60s.
* Pressing Reset means coming back to the previous menu or deleting
the previous input.
* When the users set the alarm system, the users can press
and key to reach the menu they want.
* The setup is available only when the system is in standby. During the
set, the system won’t respond any alarm. After exit from set, the system
will enter Disarm. The users have to arm accordingly if need.
There are 5 sub-menus in Phone menu, as follows:
* Set alarm phone number
* Set alarm panel report
* Set zone list for alarm phone
* Set arm/disarm report
* Set self inspection report
[Set]
[ ]
[ ]
[*] [#]
[OK]
,
4.3.1 Set the alarm phones
* There are 8 alarm phones can be set. They can be set as Normal
Phones or CID Phones. To insure the priority of CID, please set the CID
alarm phone as the 1st alarm phone.
* 28 numbers can be included in the phone. The interface will turn a new
page when input 11 digits of number.
18 19
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
1
Picture 3
Set
Telephone
1
Picture 4
Set
Telephone
1
Picture 5
Step 1: In standby, press Set
installer ’s pin to enter the
setup menu
[ ] + [
]+ [OK]
Step 4: Press 6789
If it sets successfully, the LCD
display will show PASS as Picture 7.
[12345678] + [#] + [ ]
+[OK].
Step 2: Press or to select
Phone Menu. When Phone Menu
flashes, press to enter.
[*] [*]
[OK]
Step 5: To set the number of “77880088”
as the second alarm center. Press or
to select “2” as Picture 8. It means
the 2nd phone number to be set when “
2” flashes as Picture 9-10, press
to enter.
[*] [
#]
[OK]
Step 3: It means the 1st phone
number to be set when “1” flashes,
press to enter.[OK]
Step 6: After inputting the numbers,
press to confirm and the screen
will display as Picture 11.
[OK]
Picture 7
31
Set
Telephone
2
Picture 8
Set
Telephone
Picture 6
Set
Telephone
1
Picture 9
2
Set
Telephone
2
Picture 10
Set
Telephone
2
Picture 11
Set
Telephone
20 21
*
*
Inputting [*] for 2s pause, the LCD screen will show “ ”.
Press the [phone numbers] + [OK]to setting the Normal phones;
Press [phone number] + [#] + 4-digit CID account] to set the CID
phone number. The 4-digit CID account should be in the range of
0000 9999. Input “#” , the LCD screen will show “ ”
The alarm system is connected with exterior line
directly. Now set the mobile phone number “12345678” in the 1st
alarm phone for CID, CID account 6789 Please read the following steps:
└
┘~ .
For example 1:
3
!"
#$
3
Picture 2
Set
Telephone
For example 2: The alarm system is connected with exchange line.
The “0” is required before phone number. Now set the mobile phone
number “12345678901” as the third phone. There should be a pause
exchanger. Please read the following steps:
4.3.2 Set the information Report of the alarm unit, the zones list for
related alarm phones, Arm/ Disarm Report and the self-inspection Report.
When there is alarm occurring, “ON” is for Reporting to the alarm phones
and “OFF” is turn off Reporting.
The alarm panel report: emergency alarm activated by remote controller,
emergency alarm of main unit, Tamper alarm of alarm unit, alarm activated
by wrong pin input and duress alarm.
3
Picture 1
Set
Telephone
3
Picture 2
Set
Telephone
3
Picture 3
Set
Telephone
Step 1: In the phone menu, press or
to select “3”, when “3” flashes,
press to enter.
Step 2: Press 0 * 12345678901
If the setup is successful, the
LCD display will show the PASS.Once
the numbers is beyond 11 figures, the
next figures will be displayed on
next screen.
[*]
[#]
[OK]
[ ] + [
OK].
Step 1: In standby, press
Installer ’s pin OK to enter the
setup menu.
Step 2: Press or to select
Phone Menu. When Phone Menu
flashes, press to enter.
Step 3: Press or to select the
phone number (the phone number is
programmed ready), when “2” flashes,
press to choose turn on Reporting.
Then press to make sure and
continue to press to be in ON, to turn
on Reporting.
[Set] + [
] + [ ]
[*] [#]
[OK]
[*] [#]
[Set]
[OK]
[*]
2
2
nd
nd
The zone report: Burglar and Tamper of detector, etc.
Self-inspection information: Low power of alarm unit, battery restoration,
AC-off, AC restoration, low battery of detector, zone Bypass, zone
restoration, GSM communication failure, GSM communication restoration
and Timer communication, etc.
In the Phone menu, press key repeatedly to select the sub-menu,
When there is alarm occurring on the alarm unit, the alarm
unit will Report it by the alarm phone. The operation is as follows:
[Set]
For example 1:
2nd
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
1
Picture 3
Set
Telephone
2
Picture 4
Set
2
Telephone
Picture 5
22 23
Picture 6
Set
2
Telephone
Picture 7
3
!"
#$
Set
Telephone
2
Step 4: When there is displaying PASS
on interface, it means the setting
is successful.
For example 2: When there is alarm on zone 01, 02, 06 and 12, the
system will dial the group of alarm phones. The operation is as follows:1st
For example 3: When there is alarm occurring on the alarm unit, the
system will send Arm/ Disarm Report by the 3rd alarm phone.
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
1
Picture 3Set
Telephone
1Zone
Picture 4
Step 1: In standby, press
Installer ’s pin to enter
the setup menu.
[Set] +
[ ] + [OK]
Step 2: Press or to select
Phone Menu. When Phone Menu
flashes, press to enter.
[OK] [#]
[OK]
Step 3: Press or to select
the phone number (the phone
number is programmed ready), when
“1” flashes, press twice to
reach “ Zones List” menu. Then
press to enter the menu. And
continue to press the zone number 01,
02, 06, 12.. Then press
[*] [#]
[Set]
[OK]
[OK]
1 1st st
Step 4: When there is displaying PASSon interface, it means the settingis successful.
3
!"
#$
Set
Telephone
1Zone
Picture 6
Set
Zone1
Telephone
Picture 5
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
1
Picture 3
Set
Telephone
3
Picture 4
Step 1: In standby, press
Installer ’s pin OK to enter the setup
menu.
Step 2: Press or to select
Phone Menu. When Phone Menu
flashes, press to enter.
[Set] + [
] + [ ]
[*] [#]
[OK]
24 25
Set
3
Telephone
3
Picture 5
Set
3
TelephoneDisarm
Home Arm
Away Arm
Report
Picture 6
Step 3: Press or to select the
phone number (the phone number is
programmed ready), when “3” flashes,
press Set triple
to reach arm/disarm Reporting menu.
Press to enter, Press
to choose the ON. Then press
Step 4: When there is PASS
on interface, it means the setting is
successful.
[*] [#]
[ ]
[OK] [*]
[OK]
displaying
3
3
rd
rd
Set
3
Telephone
Disarm
Home Arm
Away Arm
Report
Picture 7
3
!"
#$
Set
Telephone
3
Disarm
Home Arm
Away Arm
Report
Picture 8
For example 4: When there is Arm/ Disarm on zone 01, 02, 03, the
system will dial the group of alarm phone. The operation is as follows:3rd
Picture 1
Pin
Picture 2
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 3
1
Set
Telephone
Picture 4
3
Set
Telephone
Picture 5
Zone3
Set
Telephone
Picture 6
3
Disarm
Home Arm
Away Arm
Report
Set
Telephone
Set
3
Disarm
Home Arm
Away Arm
Telephone
Report
Picture 7
33
Picture 8
SetTelephone
Disarm
Home Arm
Away Arm
Report
Step 1: In standby, press
Installer ’s pin OK to enter the
setup menu.
Step 2: Press or to select
Phone Menu. When Phone Menu
flashes, press to enter.
[Set] + [
t] + [ ]
[*] [#]
[OK]
Step 3: Press or to select the
phone number when “3” flashes,
press twice to reach “Zones
List” menu. Then press to enter
and continue to press the zone number
01, 02, 03. Then press
Step 4; Then press to reach the
menu of “Arm/ Disarm Report”. Then
press to enter, press to choose
ON. And Press to confirm
Step 5: When there is displaying
on interface, it means the setting
is successful.
[*] [#]
[Set]
[OK]
[OK]
[Set]
[OK] [*]
[OK]
PASS
3rd
26 27
For example 5: When there is low power existing, the system will make
Report by the 6th alarm phone.
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Report6
under-voltage
Picture 7
3
!"
#$
Set
Telephone
6 Report
under-voltage
Picture 8
Report6
under-voltage
Picture 6
Set
1
Picture 3
Set
Telephone
6
Picture 4
Set
Telephone
66
Picture 5
Set
Telephone
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
1
Picture 3
Set
Telephone
6
Picture 4
Set
Telephone
28 29
For example 6: When there is low power on zone 03, the system will
make Report by the alarm phone.6th
Step 1: In standby, press
Installer ’s pin OK to enter
the setup menu.
Step 2: Press or to select
Phone Menu. When Phone
Menu flashes, press to enter.
[Set] + [
] + [ ]
[*] [#]
[Set]
Step 3: Press or to select the
phone number (the phone number
is programmed ready), when “6”
flashes, Then press repeatedly (
quartic) to reach menu of “l-power”.
press to enter the low power menu,
Press to choose ON. Then
press to confirm.
[*] [#]
[Set]
[OK]
[*]
[OK]
6
6
th
th
Step 1: In standby, press
Installer ’s pin to enter the
setup menu.
Step 2: Press or to select
Phone Menu. When Phone Menu
flashes, press to enter.
[Set] + [
] +[OK]
[*] [#]
[OK]
Step 3: Press or to select the
phone number when “6” flashes,
press Set repeatedly to choose sub-
menu of Zones List. Input zone number
03 and Then press
repeatedly (quartic) to reach menu
of “l-power Report”. press to enter
the low power menu, Press to
choose ON. Then press to
confirm.
Step 4: When there is displaying
on interface, it means the
setting is successful.
[*] [#]
[ ]
[OK] [Set]
[OK]
[*]
[OK]
PASS
,
6th
4.4 How to set Date
For example 1:
This date can be set according to local time. It is very important for Timer
Arm/ Disarm and Record of alarm items. This alarm device have equipped
with real-time module.
xx (2-digits for year) + xx (2 digits for month) + xx (2-digits for day) + xx
Time (2-digits for hour) + xx(2-digits for minute) + x(1-digit for week)
The system will be set to be 15:30 Jan. 5th, 2011. Wed..
The operation is as follow:
6Zone 6
Set
Telephone
Picture 5
Report6
under-voltage
Set
Telephone
Picture 6
6
under-voltage
Set
Telephone
Report
Picture 7
3 6
under-voltage
Set
Telephone
Report
Picture 8
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Clock
Picture 3
Set
Clock
Year Month Date Hour Minute Week
Picture 4
3
!"
#$
Set
Clock
Picture 5
Step 1: In program, press or
to select t “Date”, when the “Date”
flashes, press to confirm.
[*] [#]
[OK]
Step 2: Input 11010515303 if
the setup is successful, the LCD
screen will show “PASS”
[ ]+ [OK]
4.5 Arm/ Disarm Timer
* On the mode of Mono-user:
There are two groups of timer. Each group is composed of Arm time and
Disarm time. The operation is as follows:
The sub-menu under arm/disarm timer,
1 is first group of arm timer
2 is first group of disarm time
3 is second group of arm time
4 is second group of disarm time
In the multi-user, press to select the menu of zone list.
x (2-digits for hour) + xx (2-digits for minute) + 1-7(1-7digits for week)
two groups of Arm time and Disarm time.
It can realize to Arm/ Disarm in different time.
[Set]
x
30 31
* On the mode of Multi-user: two groups of Arm time and Disarm time are
corresponded to 8 users.
(Note: The specifications are referred to the term of 4.10.)
Note:
The time set for two groups are not allowed in the same. Otherwise,
the set is not useful.
On the mode of Mono-user, the system will turn off the function of “
Zones List of Timer Arm/ Disarm”.
Ȩ
Ȩ
For example 1: On the mode of Multi-user, the first group of timer of
01, 02, 03 zones, from Monday to Friday.
Arm time is 00:00, Disarm time is 08:00. The operation is as follows:
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
1
Picture 3
1
Set
Timer
Year Month Mon. Sun.~
Picture 4
3
!"
#$
Set
Timer1
Picture 5
2
Set
Timer
Picture 6
Set
Zone1
Timer
Picture 8
3
!"
#$
2
Picture 7
Set
Timer
1
Picture 9
Set
Zone
Timer
31
Picture 10
Set
Zone
Timer
Step 3: Press [*] or [#] to select “2”, “2”
is for disarm time of first group. Press [
OK] to confirm.
Step 4: Press [080012345] + [OK]
if the set is successful, the LCD will
show PASS.
[Set]
[OK]
[ ] + [OK]
Step 5: In program, press to
select the Zones List of Timer Arm/
Disarm, if this menu flashes, press
to enter.
Step 6: Press 010203 if
the set is successful, the LCD will show
PASS.
Note: “3” and “4” are for the Arm and Disarm for second group timer. Users
can set accordingly.
32 33
Step 1: In program, press or
to select the Timer, if Timer
Menu flashes, press to
enter.
Step 2: “1” is for Arm of first
timer, press to confirm.
Press 080012345
if the set is successful, the LCD
will show PASS.
[*] [
#]
[OK]
[OK]
[ ] + [OK],
4.6 Zone list
On the mode of Mono-user:
On the mode of Multi-user:
For example 1:
* relate to the corresponding Arm/ Disarm
Zones List.
* relate to the corresponding Away Zones
List of 8 users. Each user ’s zones list can be set alternately.
(Note: The selection of modes of Mono-user and Multi-user can be
referred on the item of 4.10 “How to set Report”).
Note: A) The zone number should be fixed to be 2 figures.
B) The Zones List of Mono-user & Multi-user modes can be
conserved separately. If the user exchanges the mode, the Zone List
would return to Default State.
On the mode of Multi-user, set the Zones List of the 1st
user: 03, 04, 11, 16 zone. The operation is as follow:
Pin
Picture 1
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
1
Set
Zone
Away Arm
Picture 3
1
Set
Zone
Away Arm
Picture 3
Set
Zone1
Telephone
Away Arm
Picture 4
Set
Zone1
Telephone
Away Arm
Picture 4
3
!"
#$
Set
Zone1
Away Arm
Picture 5
Step 1: In program, and in Mode of
Multi-user. Press or to select the
Zone, when Zone menu flashes,
press to enter the item of “
Away Arm”.
Step 2: In the zone menu, there is “1”
existing, “1” for zone list. When “1”
flashes, press OK to confirm, the
press 03, 04, 11, 16 to set the
Zones List. If the program sets
successfully, the LCD display
will show PASS.
[*] [#]
[OK]
[ ]
[ ] + [OK]
For example 2: On the mode of Mono-user, set the Zones List of Away
Arm: 03, 04, 11, 16 zone; Set the Zones List of Home Arm: 01, 02, 03,
14, 15 zone
3
!"
#$
Set
Zone 1
Away Arm
Picture 5
Step 1: In program, supposed that the
Mode of Multi-user has been existed on
the item of “Report”. Press or to
select the Zone, when Zone menu
flashes, press to enter.
Step 2: In the zone menu, there have “1”
and “2”, “1” for zone list of Away arm, “2”
for zone list of home arm. When : “1”
flashes, press to confirm, the
press 03, 04, 11, 16 to set the
zone list of Away home. If the program
sets successfully, the LCD display will
show PASS.
Step 3: In this zone menu. Press
or to select “2” to set the zone list
of home arm, when “2” flashes, press
to confirm
[*] [#]
[OK]
[OK]
[ ] + [OK]
[*]
[#]
[
OK]
34 35
Away Arm
Home Arm
Disarm
Burglar Perimeter Duress Panic Fire MedicalGas
2
Set
Zone
Home Arm
Picture 6
Picture 7
Set
Zone2
Home Arm
Picture 8
3
!"
#$
Set
Zone2
Home Arm
Step 4: Press 01, 02, 03, 14, 15
to set the zone list of home arm.
If the set is successful, the LCD screen
will show PASS.
[ ] + [
OK]
4.7 Zone Attribute
The system can set output of alarm panel. And set output and attributes
of each zone separately. There are three kinds of output. As follows
On-spot alarm. “1” is ON and “0” is OFF.
Linkage output, “1” is ON and “0” is OFF.
Wireless siren, “1” is ON and “0” is OFF.
There are 7 kinds of zone attributes. The users can define the different
zones according to the need. There are Burglar, Perimeter, Duress,
Panic, Fire, Gas and Medical attribute.
The Attribute of alarm output adopts 2 digits of binary system. The first
digit is for “on-spot Alarm”, the second one is for “linkage Output” and
the third one is for “Wireless Siren”. “1” is ON and “0” is OFF.
Note: “ means alarm can be activate when the system is triggered;
“×” means alarm can’t be activate when the system is triggered.
”√
For example 1: When there is Tamper alarm existing, the modes of
on-spot Alarm, Iinkage Output and Wireless Siren are opened.
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Attribute
Picture 3
Set
Attribute
Picture 4
Step 1. In the program, press or
to select Attribute. When Attribute Menu
flashes, press to enter.
Step 2: Input “111” to select the
modes of on-spot Alarm, Linkage
Output and Wireless Siren n.
Then press to confirm.
[*] [#]
[OK]
[OK]
36 37
5
Set
Attribute
Burglar
Picture 4
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Attribute
Set
Picture 5
3
!"
#$
Set
Attribute
Picture 6
For example 2: Set zone 5 to be Perimeter. And open modes of Alarm
On-spot and Wireless Siren and turn off the mode of linkage output
when there is alarm existing.
Step 1. In the program, press or
to select Attribute. When Attribute
Menu flashes, press to enter.
Step 2: press or to reach “5” (“
5” is in flash). press to confirm
for zone number
Step 3: Input “101” to select the
modes of on-spot Alarm, Iinkage
Output and Wireless Siren.
[*] [#]
[*]
[*] [#]
[OK]
Set
Attribute
Picture 3
5
Set
Attribute
Burglar
Picture 5
5
Set
Attribute
Perimeter
Picture 6
Step 4. Press [*] or [#] to reach “
Perimeter” (“Perimeter” is in flash).
Press [OK] to confirm.
4.8 Modify pin
* On the mode of Mono-user: two levels of pins: “Installer ’s Code”
and “User ’s Code”
* On the mode of Multi-user: three levels of pins: “Installer ’s Code”, “
master ’s Code” and “User ’s Code”.
“Installer ’s Code”: in the status of installing, it can set for all the items.
It is set to be 6 digits of “000000-999999”. “000000” is default setting.
“master ’s Code”: it can set the items of Real-time, Timer Arm/ Disarm
and User ’s Code, etc. It is set to be 4 digits of “0000-9999”. “0000” is
default setting. Please revise the master ’s Code from your purchasing
to avoid letting the pin out.
“User ’s Code”: it can be set for Remote Setting, Arm/ Disarm of the
system on the mode of Multi-user. It should be set to be 4 digits of “
0000-9999”.
“Duress Code”: the duress pin is existed automatically by pulsing
number “1” with the last number of master ’s Code or User ’s Code. If the
last number is “9”, the last number of Duress Code is “0”. The other front
numbers are the same. For example: the master ’s Code is 1239. The
Duress Code will be 1230.
The format is: in the status of Code setting, input New Code OK
New Code OK
[ ] + [ ] + [
] + [ ] .
38 39
(Note: the setting selection of Mono-user mode and Multi-user mode
can be referred on the item of “Report”.)
Note: The master ’s pin, 8 user ’s pin and dress’ pin can’t be set as
the same.
On the mode of Multi-user, set the User ’s Code of the
zone as 1357. The operation is as follow:
For example 1: 5th
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Set
Picture 3
Pin
1
Set
Picture 4
Pin
5
Set
Picture 5
3
!"
#$
Set
Pin
5
Picture 6
Step 1: In the program, and alarm panel
in working mode of Multi-user.
Press or to select Pin. When Pin
Menu flashes, press to enter.
Step 2: Press twice to enter “
User ’s Code”.
Step 3: When “1” is flashing, it means
the 1st User ’s Code. Press or to
reach “5”. Press to confirm and
input the New Code of 1357 OK
1357 again. The LCD screen
will show PASS if the set is successful.
[*] [#]
[OK]
[Set]
[*] [#]
[OK]
[ ] + [ ] & [
] + [OK]
For example 2: Set the master ’s pin as 1111, the operation as follows:
Step 1. In the program, and alarm panel in working mode of Multi-user.
Press or to select Pin. When Pin menu flash, press to enter.
Step 2: Press to enter “master ’s Code”.
Step 3: input the New Code of 1111 1111 again.
The LCD screen will show PASS if the set is successful.
[*] [#] [OK]
[Set]
[ ] + [OK] & [ ] + [OK]
4.9 How to set delay
4.9.1 Alarm Delay
For example 1:
There are sub-menus in Delay. As follows
1 for alarm delay
2 for arm delay
3 for siren duration
4 for ringing times
5 for circulated dialing times
6 for timer communication
The Alarm Delay is the time range that is from the alarm trigger to the
alarm activate.
The time range: 000 255s. If Alarm Delay time is “000”, that means
alarm at once.
Set the Alarm Delay to be 20s.
~
Pin
Picture 1
40 41
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
1
Delay
Set
Picture 3
1
Delay
Set
Picture 3
221
Set
Delay
Picture 4
Step 1: In program, press or to
choose “Delay”, when the Delay Menu
flashes, then press to enter.
Step 2: “1” is for Alarm Delay, when “1”
flashes, press to confirm.
Step 3: press to set the
Alarm Delay. If the set is successful,
the LCD screen will show PASS.
[*] [#]
[OK]
[OK]
[020] + [OK]
4.9.2 Arm Delay
For example 1:
Arm Delay is the time range from Armed by users to the arm activation.
The time range: 000 255s. “000” mean Arm activate at once.
Set the Arm Delay to be 30s.
~
Pin
Picture 1
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
1
Set
Delay
Picture 3
2
Set
Delay
Picture 4
2
Set
Delay
Picture 5
3
!"
#$
Set
Delay
2
Picture 6
Step 1: In program, press or to
choose “Delay”, when Delay Menu
flashes, then press to enter.
Step 2: Press or to choose “2”. “
2” is for Arm Delay , when “2” flashes,
press to enter.
Step 3: Press to set the
Arm Delay. If the set is successful,
the LCD screen will show PASS.
[*] [#]
[OK]
[*] [#]
[OK]
[030] + [OK]
4.9.3 Siren duration
For example 1:
The range of siren duration is 01-99 minutes. It should be 2 digits.
set the alarm sound time as 30 minutes. The operation
is as follow:
Pin
Picture 1
42 43
1
Set
Delay
Picture 3
3
Set
Delay
3
Set
Delay
3
!"
#$
Set
Delay
3
Picture 4
Picture 5
Picture 6
Step 1: In program, press or to
choose “Delay”, when Delay menu
flashes, then press to enter.
Step 2: Press or to
select “3”. “3” is for Alarm sound time.
When “3” flashes, press to enter.
Step 3: Press to set the
Alarm sound time. If the set is
successful, the LCD screen will
show PASS.
[*] [#]
[OK]
[*] [#]
[OK]
[30] + [OK]
4.9.4 Set ringing times
For example 1:
Dial the phone when the alarm connected, if the times of ring arrives
that users set, the alarm system will enter the remote set automatically.
The ring times range is 03-15 times. It should be 2 figures.
Set the ring times to be 10 times.
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Picture 1
1
Set
Delay
Picture 3
4
Set
Delay
Picture 4
4
Set
Delay
Picture 5
3
!"
#$
Set
Delay
4
Picture 6
Step 1: In program, press or to
choose “Delay”. When the Delay Menu
flashes, press to enter.
Step 2. Users can see “1” is flashing
and press or to choose “4”. “4”
is for ring time, press to confirm
Step 3. Press to set the
ring time
Note:
* The ringing times are suggested to be set more times, otherwise it may a
ffect the daily use.
* It is suggested to set the ringing times to be more than 5 times. If users
not used remote set, the ringing times can be set to be 15 times.
[*] [#]
[OK]
[*] [#]
[OK]
[10] + [OK]
4.9.5 Set dialing time
For example 1:
The range of dialing times is 03-15. The number shall be 2 figures.
Set the dialing times to be 10 times.
44 45
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2 Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Picture 1
Pin
Picture 1
1
Set
Delay
Picture 3
5
Set
Delay
Picture 4
5
Set
Delay
Picture 5
3
!"
#$
Set
Delay
5
Picture 6
Step 1. In Program, press or to
choose “Delay”. When Delay Menu
flashes, press to enter.
Step 2: users can see “1” is flashing
and press or to choose “5”. “5”
is for ring time. Press to confirm.
Step 3. Press to set the
ring times. If the set is successful,
the LCD screen will show PASS.
[*] [#]
[OK]
[*] [#]
[OK]
[10] + [OK]
4.9.6 Timer Communication
The timer communication is the communication between alarm panel
and alarm center or users by telephone regular time. The range is: 00-
99hours. The time of Timer communication is counted when power on.
‘00’ is to off the Timer communication.
Note: the Timer Communication would be re-counted once power off.
set the timer communication to be 24 hours for alarm
panel and alarm center.
For example:
1
Set
Delay
Picture 3
6
Set
Delay
Picture 4
6
Set
Delay
Picture 5
3
!"
#$
Set
Delay
6
Picture 6
Step 1. In the program, press or
to select Delay. When Delay Menu
flashes, press to enter.
Step 2: when “1” flashes, press or
to choose “6”. “6” is for Timer
communication. Press to confirm
Step 3: Press to set the
Timer Communication. If the set is
successful, the LCD screen will
show PASS.
[*] [#]
[OK]
[*] [
OK]
[OK]
[24] + [OK]
46 47
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Picture 1
Pin
Picture 1
4.10 How to set Repor
For example 1:
t
There are sub-menus in Report. As follows:
1 for Working mode of alarm system (mono-user/multi-users),
2 for Relay Report,
3 for remote switch by alarm center
4 for Compulsory Arm Switch
4.10.1 How to select working mode of alarm panel
There are two modes for option: Mono-user and Multi-user.
ON for mono-users, OFF for multi-user.
In the mode of Mono-user: set Away Arm and Home Arm of the system
In the mode of Multi-user: 8 users can set by their corresponding remote
controller and user ’s code. Each remote controller can Arm/ Disarm its
corresponding user independently.
Set the mode of the system as Mono-user mode. The
operation is as follow:
Set
Report1
Picture 3
Set
Report1
Picture 4
3
!"
#$
Set
1Report
Picture 5
Step 1: In program, Press or to
choose “Report”. When Report Menu
flashes, press to enter.
Step 2: “1” is for set the working mode
of panel., when “1” flashes, press
to enter.
Step 3: Press or to choose “
ON” or “OFF”. ON for mono-users,
OFF for multi-user.
[*] [#]
[OK]
[OK]
[*] [OK]
Step 4. Choose the ON, and press
to confirm. If the set is successful,
the LCD screen with show PASS.
[OK]
4.10.2 Relay Report
Users can set ON/OFF for integrated devices when alarm status change (
like arm, disarm or alarm).The information is listed as follows:
Indications Alarm
Siren
Alarm Light
Warning Sign
activate
Light
Red lightflash quickly
Arm
A “Di”
Flash once
Green light flashonce per 5s
Disarm
Flash twice
Red light flashonce per 5s
Red light flashonce per 5s
IntegratedDevices
For example 1: Turn on “Relay Report”
Step 1: In program, Press or to
choose “Report”. When “report”
Menu flashes, press to enter.
[*] [#]
[OK]
48 49
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Picture 1
Set
Report1
Set
Report2
Set
Report2
3
!"
#$
Set
Telephone
2Report
Step 2: “2” is for Relay report ON/OFF,
press or to choose “2” when “2”
flashes, press to enter.
Step 3: press or to choose “ON”
or “OFF”.
Step 4. choose the ON, and press
to confirm. If the set is successful, the
LCD screen with show PASS.
[*] [#]
[OK]
[*] [#]
[OK]
4.10.3 Remote Switch by alarm center
For example 1:
“ON” is to tune on, OFF is to turn off the remote switch by alarm center.
Note: the alarm center shall be assigned by factory.
the alarm unit allows to be controlled remotely. The
operation is as follow:
Set
Report1
Picture 3
Set
Report3
Picture 4Set
Report3
Picture 5
3
!"
#$
Set
Telephone
3Report
Picture 6
Step 1: In program, press or to
choose “Report”. When “report” Menu
flashes, press to enter.
Step 2: When “1” is flashing, press
or to reach “3”. Press to enter,
press to choose “ON”. Then press
again to make confirmation.
[*] [#]
[OK]
[*]
[#] [OK]
[*] [
OK]
4.10.4 Compulsory Arm switch
“ON” is to tune on, OFF is to turn off the switch.
Compulsory Arm: when wired zone is in trouble, it allows the user Arm
this zone. The system will Bypass the troubled zone automatically. Once
the troubled zone restores, this zone will enter the status of Arm.
Un-compulsory Arm: when wired zone is in trouble, it doesn’t allow the
user Arm this zone. The zone’s trouble should be deleted at first, then it
can be Armed again.
Picture 6
Picture 5
Picture 5
Picture 5
50 51
Note: If Compulsory Arm is activated, the troubled zones still exist in
arm status.
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Picture 1
Pin
Picture 1
Set
Report1
Picture 3
Set
Report4
Picture 4
Set
Report4
Picture 5
3
!"
#$
Set
4Report
Picture 6
For example 1: the alarm unit allows to Compulsory Arm. The operation
is as follow:
Step 1: In program, press or to
choose “Report”. When “Report” Menu
flashes, press to enter.
Step 2: When “1” is flashing, press
or to reach “4” is for Compulsory
Arm ON/OFF, press to enter.
press to choose “ON”. Then press
again to make confirmation.
[*] [#]
[OK]
[*]
[#]
[OK]
[*] [
OK]
4.11 How to make enrollment
There are sub-menus in Enrollment. As follows,
1 is for 1-16 zones detectors enrollment
2 is for 1- 8 remote controllers enrollment
The standard kit has collocated wireless accessories (such as wireless
door sensor, detector and remote controller) when they are ex-factory.
If the users need to add additional detectors or remote controllers, the
operation as follows:
Note:
4.11.1 Enroll detectors
For example 1:
In the process of enrolling, a long “Di” is to alert users that the
detector has been existed in alarm system, the repeated enrol is not
allowed.
The system supports 16 wireless zones and each zone can enroll 3
detectors.
In the zone menu, 1 for detector, 2 for detector, 3 for detector
of this zone
Users can trigger the detector to send the signal by power switch,
tamper switch or trigger PIR.
Enroll with the detectors of the detector on the zone.
1 2 3
1 2
st nd rd
st nd
Step 1: In program, press or to
choose “Enroll”. When Enroll menu
flashes, press to enter.
[*] [#]
[OK]
52 53
Step 2: Press or to choose “1”. “
1” is for Enroll Detectors, when “1”
flashes,press to enter.
Step 3: Press or toreach “2”. “2”
is for the 2nd zone. Press to
confirm
Step 4. Trigger detector. Once
the alarm system receives the
signal, the LCD screen will
show the code of detector. That
means the set is successful
[*] [#]
[OK]
[*] [#]
[OK]
1
Set
Zone
Enroll
Picture 3
Set
Zone
Enroll
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
Picture 4
Set
Zone
Enroll
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
Picture 5
21 3
Picture 6
Set
Zone
Enroll
21 3
Picture 7
Set
Zone
Enroll
4.11.2 Delete the enrolled detectors
4.11.3 Enroll remote controllers
For example 1: Delete the enrolled detector of the detector on the
zone. Please repeat the operation of Step 1-3 on 4.11.1. Then set as
follow:
Press twice. If the LCD screen show as Picture, the deletion is
successful.
[OK]
1 2st nd
The system supports 8 remote controllers and each remote controller
corresponds with the 8 users or main user.
Enroll of remote controller in number.For example 1: 5th
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Pin
Picture 1
1 2 3 4 5 6 7 8
Set
Enroll
1
Set
Zone
Enroll
Picture 3
Picture 4
1 2 3 4 5 6 7 8
Set
Enroll
Picture 5
5
Set
Enroll
1 2 3 4 5 6 7 8
Picture 6
Step 1: In program, press or to
reach “Enroll”. When Enroll Menu
flashes, press to enter.
Step 2: Press or to choose “2”. “
2” is for remote controller program,
when “2” flashes, press to enter.
Step 3: Press or to choose “5”. “5”
is for the remote controller. Press
to enter
Step 4. Trigger any key of remote
controller to remit. Once the alarm
system receives the signal, the LCD
screen will show the code of remote
controller, it means the set is
successful
[*] [OK]
[OK]
[*] [#]
[OK]
[*] [#]
[
OK]
5th
54 55
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2
Set
Telephone
Clock
Timer
Zone
Attribute
Pin
Delay Record/ Playback
Siren
Enroll
Report
Picture 2Pin
Picture 1
Pin
Picture 1
4.11.4 Delete the enrolled remote controller
For example 1: Delete the enrolled detector of the 5th remote controller.
Please repeat the operation of Step 1-3 on 4.11.3. Then set as follow:
5
Set
Enroll
1 2 3 4 5 6 7 8
Picture 1
Set
Enroll
1 2 3 4 5 6 7 8
Picture 2
Press twice. If the LCD screen
show as Picture, the deletion
is successful.
[OK]
4.12 Wireless siren code
For example 1:
The “siren” menu is to enroll the code of wireless siren. The wireless
siren code should be as 8 digits quaternary.
The wireless siren output shall refer to 4.7 attributes.
Set wireless siren code as “12332100”. The
operation is as follow:
Set
Siren1
Picture 5
3
!"
#$
Set
Siren
1
Picture 6
1
Set
Siren
Picture 3
Step 1: In program, press or to
reach “Siren”, when the Siren Menu
flashes, Press to enter.
[*] [#]
[OK]
Step 2. Press 12332100 to set
the wireless siren code. And press
again to make confirmation. If the set is
successful, the LCD will show PASS.
[OK] + [ ]
[OK]
4.13 Voice Record
The system supports 20s Voice Record to record the alarm information
by users. The operation is as follows:
2
Set
Record/ Playback
1
Set
Record/ Playback
Picture 3
Picture 4
Step 1. In program, press or to
reach “Rec/Play”. When “Rec/Play”
Menu flashes, press to enter.
Step 2. Press or to reach “2” , “
2” is for record new voice, press
to start to record. The voice is not
beyond 20 seconds, press to
finish the voice record.
[*] [OK]
[OK]
[*] [#]
[OK]
[OK]
56 57
Step 3: After finishing record, “2” is
flashing. Press or toreach “1” ,
and press toplayback the
recorded voice.
1. It is suggested to playback
and check the new record. Rerecord
the voice once unsatisfied.
2. In order to prolong the ringing time
when receiving the alarm phone,
the record voice should be
considered to extend.
[*] [#]
[OK]
Note:
2
Set
Record/ Playback
Picture 5
1
Set
Record/ Playback
Picture 6
1
Set
Record/ Playback
Picture 6
4.14 Factory default
ZoneMono-user mode
Multi-user mode
Away Zones List ofmain user
Home Zones Listof main user
Away Zones List ofthe 1st-8th users
01020304050607080910111213141516
01020304050607080910111213141516
01020304050607080910111213141516
Attribute
Main unit
16 zones 110/ burglar
110
No. Programming Items Factory Default
1 Phone
8 groups of phones
8 groups of Alarm Report
8 groups of Zones List
Blank
ON
01020304050607080910111213141516
8 groups of Arm/ Disarm Report OFF
8 groups of Self-inspection Report OFF
Clock2
3
4
5
Timer
Mono-user mode2 groups of TimerArm/ DisarmDisarm Blank
BlankMulti-user mode
2 groups of TimerArm/ Disarm
2 groups of user ’sZones List
0102030405060708
Playback
Record00
6 Code
Mono-user
Multi-user
Installer's Code
Master's Code
Installer ’s Code
Master's Code
User's Code
000000
000000
1234
1234
Blank
7 Delay
Delay Alarm
Delay Arm
Alarm Sound Time
Ringing Times
Dialing Times
Timer Communications
000 (No delay)
000 (No delay)
05
05
03
00 (No communication)
8 Report
System Mode
Relay Report
Remote Controlling Switch
Compulsory Arm Switch
OFF (Multi-user mode)
OFF
OFF
OFF
9 Enroll
Enroll detectors
Enroll remote controllers
Blank
Two remote controllers
Siren Wireless siren code 00000000
11VoiceRecord/Playback
10
4.15 Installer set
A)Recover the installer’s code to be factory default (000000).
Installer code is 12*48#.
In Installer Set menu, 1 is for “Recover installer ’s code”. 2 is for
“recover the factory default”
Picture 1
Step 1: In standby, Press [12*48# ] + [
OK]
58 59
1
Picture 2
1
Picture 3
Step 2: Users can see “1” flashing.
Press to recover the installer ’s
code to factory default (000000).
If the set is successful, The LCD
screen will show PASS.
[OK]
B) Recover the factory default
Picture 1
1
Picture 2
2
Picture 3
2
Picture 4
2
Picture 5
Step 1: In standby, Press 12*48#
Step 2: Users can see “1” flash. Press
or to reach “2”. When “2” flashes,
press to delete all setting to
factory default. If the set is successful,
the LCD screen will show PASS.
Please don’t operate the
other items haven’t been
mentioned on the manual without
permission.
[ ] + [
OK]
[
*] [#]
[OK]
Note:
Ⅴ Technology Parameter
Maintenance
Size: 264.2 X 179.6 X 47.6 mm (L*W*H), error ±1mm
Power: AC220V DC13.8V 500mA
Wireless distance: (PIR to unit) 300m
Wireless frequency: 433.92MHz:
AUX output current: 80mA
150mA (with GSM)
Wireless modulation: OOK
Assistant Power: DC12V 150mA
Alarm decibel: 90dB ( Max & Within 1m)
Working environment: Working Temperature: -10℃ 55℃
Relative Humidity: 10% 80%
It is suggested to test the system per one month to make sure the
normal working of the system.
Please take cotton cloth or sponges with water to clean the alarm unit.
Note: Don’t use anything with organic solvents to clean the system,
such as coil oil, superglue, etc. Lest should destroy the system.
5.1 Alarm unit
6.1 Regular test
6.2 Clean the alarm unit
≥
≤
≤
>
~+
~
Ⅵ
Ⅶ Exclude the Simple Troubles
Low-battery on is reported fromone zone.
The battery is of low power. Change the detector ’s battery.
Wrong alarm of wirelessdetector in usual
The installation positionis wrong.
Battery is of low power.Indicator flashes onceper 5s.
Re-install the detector.
Change the battery.
Situations Reasons Solutions
Press the remote controller butwithout enlightened indicator. Orthe distance of remote controller istoo close.
Low power of the remotecontroller.
Change the battery of the remotecontroller.
60 61
Check whether the anode &cathode of power wire and signalterminal are connected right ornot; check whether the terminal istightened up or not.
Connect with 2.2K sewingresistance as the manualinstruction.
Wrong connection ordefect touch.
Wrong connection withsewing resistance.
The wired zone doesn’t makealarm or alarm wrong whentriggered.
The system can’t dial the alarmphones when the extensionphone was received.
Check whether there iswrong connectionbetween the phone lineand local calls line.
Change the position betweenthem.
When the alarm system is instandby status, the systemdidn’t indicate with line-cut.
Test whether line-cut isON or not.
Turn “Test for line-cut” to ON asmanual instruction.
The clock can’t work normally.
The button battery ofthe unit is destroyed.
The crystal of clockchip isn’t activated.
Change the button battery
Re-set the time of system.
“Burglar” and “Perimeter”zones can not make alarm bytriggering in Arm status.
The zone list is not setcorrect.
Re-set the zone list.
There is no alarm on-site, whenthe alarm system is makingalarm.
1.The system was set tobe Mute alarm;2.The zone attributewas defined as“Duress”.
Re-set the system according tothe setting of manual.
The wireless siren can not makealarm in gear, when the alarmsystem is making alarm.
1.The address code ofsiren was set to bewrong.2.The function of Sirenwas not ON.
Re-set the system according tothe setting of manual.
It can’t be Armed.The wired zone is introuble.
Restore the wired zone or turn oncompulsory Arm.
3 Intruders may gain access through unprotected openings or have the
technical sophistication to bypass an alarm sensor or disconnect an
alarm warning device. Passive Infrared Motion Detectors can only
detect intrusion within the designed ranges as diagrammed in their
installation manual. They do not provide volumetric area protection.
They can not detect motion or intrusion that takes place behind walls,
ceiling, floors, closed doors, glass partitions, glass doors, or windows.
4 Passive Infrared Detector sense changes in temperature; however,
as the ambient temperature of protected area approaches the
temperature range of to , the detection performance will
decrease.
5 It is exiting no-power or battery-aging.
6 Alarm warning devices such as sirens, bells or horns may not alert
people or wake up sleeper if they are located on the other side of closed
or partly open doors.
7 Phone lines needed to transmit alarm signals from a premise to a
central monitoring station may be out of service or temporarily out of
service. Phone lines are also subject to compromise by sophisticated
intruders.
8 The most common cause of an alarm system not functioning when an
intrusion or fire occurs is inadequate maintenance. This alarm system
should be tested weekly to make sure all sensors and transmitters are
working properly.
9 The wireless communication distance is the testing figure in open
area. Please make sure no obstacle in the surrounding environment to
guarantee the reliability of the wireless communication distance
farther.
30 40℃ ℃
Ⅷ The limitation of this alarm system
While this system is an advanced design security system, it does not
offer guaranteed protection against burglar or fire or other emergency.
Any alarm systems, whether commercial or residential, is subject to
compromise or failure to warn for variety of reasons. For example:
1 Owing to the omission of the user, the system wasn’t Armed.
2 Misunderstanding on the user ’s manual by the user or installer
causes the abnormal working of the system.
62 63
10 If you disagree with the above mentioned items, please return the
alarm system to our company within 3 days from purchasing. Installing
an alarm system may make one eligible for lower insurance rates, but
an alarm system is not a substitute for insurance. Homeowners,
property owners and renters should continue to act prudently
themselves and continue to insure their lives and property.
64