View
1.771
Download
17
Embed Size (px)
DESCRIPTION
@ http://www.vedard.com You can find the professional security systems supplier from China manufacturer. Retail & wholesale home security systems, and home security store online for easy purchase from China producer. Buy home security systems, alarm systems from China with low price and detailed installation
Citation preview
………………………………………………………………( )1
…………………………………………………( )1
…………………………………………………( )3
………………………………………………( )3
………………………………( )4
……………………………………………( )5
………………………( )5
…………………………………………( )5
…………………………( )6
………………………………………( )7
…………………………………………( )7
…………………………………………( )8
……………………………………………………( )8
………………………………………………( )8
………………………………………………………( )8
……………………………………………( )9
…………………………………………………( )11
…………………………………………( )12
……………………………………………………………( )13
……………………………………………( )13
………………………………………( )13
…………………………………………………( )14
………………………………………………( )15
………………………………………………( )15
………………………………………………………( )16
……………………………………………………( )16
………………………………………………( )17
…………………………………………………………( )17
……………………………………………………( )18
……………………………………………………( )18
Alarm Record & Query
How to set telephones / CID
How to set DATE
Timer Arm/ Disarm
Zone List Set
Set Attributes
Set the Alarm Delay
Arm Delay
Siren duration
Set ring time
…… 26…………………( )
…… 29…………………( )
…………………………………………………( )19
……………………………………………………( )19
…………… 20………………………………………( )
……………………………………………………( )20
…………………… 21……………………………( )
……………………………( )21
…… 23………………………………………( )
…………………………………………………( )24
………………………………………………………( )24
………………………………………………( )25
…………………………………………………………( )25
………………………………………………………( )25
………………………………………………( )25
………………………………………( )31
…………………………………( )35
……………………………………( )19CID Timer Communication
Set dialing time
Relay Report
CID Report
Wireless Siren
Enroll Detectors/Remote controllers
Index table of setting
Factory Default
Voice Record
Overhaul
1. .
2. .
( )Picture 1 Sketch diagram of panel
Network Intelligent Alarm System
Function key
Number key
MIC
Horn
Indicator
LCD display
①
②
③
④
⑤
⑥
Dial
GSM
DC
Arm
Alarm
Set
Reset
Query OK
Mon SunTues Wed Thur Fri SatPhone
ZoneAttribute
DateTimer
Enroll
1 83 4 5 6 72
9 1611 12 13 14 1510
Burglary MedicalDuress Panic Fire GasPerimeterLine-Cut AC DC L-Power GSMFault
Disarm
Home Arm
Away Arm
SirenRec/Play
Report
Delay
Set
Pin
( )Picture 2 LCD View
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
Wed.
Away Arm
month day hour minuteStatus
(Picture 3) Sketch diagram in standby
Mon SunTues Wed Thur Fri SatPhone
ZoneAttribute
DateTimer
Enroll
1 83 4 5 6 72
9 1611 12 13 14 1510
Burglary MedicalDuress Panic Fire GasPerimeterLine-Cut AC DC L-Power GSMFault
Disarm
Home Arm
Away Arm
SirenRec/Play
Report
Delay
Set
Pin
3. .
⑦
4. .
⑦
“GSM” Indicator: This function is for option. When GSM module was
chosen, the indicator will indicate the situation of the wireless signal
of GSM module as follows:
A) ON: normal signal
B) Flashing: weak signal
C) OFF: too weak signal or of no signal. It will affect the
communication of GSM. Moreover, if “GSM” indicator is still OFF
after power it on 3 minutes, it is necessary to check the installation
of SIM card.
1!" 2!" 3!" 4!" 5!" 6!"
7!" 8!" #$ %&' ()' *+
7 8 9 5 : ; <KS-110B $ABCD'
EFG:;<*HIJKL
1 2 3
4 5 6
7 8 9
* 0 #
A B
C D/0 1$
23 %&E F
=> ?@
Spot Monitor
On-siteAlarm
TelephoneAlarm
Emergency
Arm/ Disarm
Remote Set
Alarm Unit
Wireless DoorSensor
Wireless PIRDetector
Wireless SmokeSensor
Wireless GasSensor
Remote Controller
Emergency Button
Telephone
Mobile
CID
Wireless Siren
Wired Siren
Alarm process
Remote Set
Alarm process
Emergency
Network Intelligent Alarm System (433.92MHz)
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
,-.
4567
1!" 2!" 3!" 4!" 5!" 6!"
7!" 8!" #$ %&' ()' *+
7 8 9 5 : ; <KS-110B $ABCD'
EFG:;<*HIJKL
1 2 3
4 5 6
7 8 9
* 0 #
A B
C D/0 1$
23 %&E F
=> ?@
SpotMonitor
On-siteAlarm
TelephoneAlarm
Emergency
Arm/ Disarm
Remote Set
Alarm Unit
WirelessDoor Sensor
Wireless PIRDetector
WirelessSmoke Sensor
WirelessGas Sensor
Remote Controller
Emergency Button
Telephone
Mobile
CID
Wired Siren
Alarm process
Remote Set
Alarm process
Emergency
Network Intelligent Alarm System (315.65MHz)
Repeater1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
,-.
4567
5. .
Picture 4TamperSwitch
Wiring slot
Batterycase
Wiring terminal
1
11
Picture a Picture b
5. .
panel
152mm
79
.9m
m
under mounting hole
upper mounting hole
Picture 5
Picture 6
5.5mm
Picture 7
(
)
Note: Three screws
installed are away
from wall 5.5mm as
picture showing
K1OFF ON
LINE PHONE
LINE
Picture 8
( line inspect switch)( OFF for close inspection)
(ON for start inspection)
(Volume: L→H)
(Telephone connection)
6. .
Z16 GND Z15 Z14 GND Z13 AUX GND
(PIR detector (NC) Emergency button (NO)
GND
GND
GND
The connection way of multiple NC detectors
Detector 1 Detector 2 Detector 3
The connection way of multiple NO detectors
Detector 1Detector 2 Detector 3
The integrated connection way of NO/ NC detectors
7. .
Detector 1 Detector 2 Detector 3
Wired detectors installation
AUXGNDNO COM NC
DC 12V wired siren(max current 150mA)>
Adapter
DC 12V wired siren(max current 150mA)<
AUXGNDNO COM NC
anode
cathode
Wire
Re
dfo
ra
no
de
Bla
ck
forcath
ode
Re
dfo
ra
no
de
Bla
ck
forcath
ode
8. .
~ ~di [ ]:1 Away Arm
Picture 9
[ ]:2 Home Arm
[ ]:4 Disarm
9. .
The detector sendsthe alarm signal tothe alarm system.
Make alarm and dial the settelephones after receivingthe alarm signal.
After receiving the alarm, youcan operate the alarm systemon the key of telephone as follows:
: :
: :
: :
[0][#] [1][#]
[2][#] [3][#]
[4][#] [5][#]
Exit Away Arm
Eliminate Alarm & Disarm Spot siren on/off
Monitor the spot Repeat the record
Picture 10
10. .
LCD Screen
KS-899 433MHz( )
The first Tel
Alarmcenter
1!" 2!" 3!" 4!" 5!" 6!"
7!" 8!" #$ %&' ()' *+
7 8 9 5 : ; <KS-110B $ABCD'
EFG:;<*HIJKL
1 2 3
4 5 6
7 8 9
* 0 #
A B
C D/0 1$
23 %&E F
=> ?@
Arm
/ Disarm
Em
erg
ency
Monitoron-s
ite
2. After receiving alarm, the alarm system will dial
the set telephones in order. If the Alarm on-site is
set, the alarm system will make alarm on-site at the
same time.
1. The detector
triggered and send
signal to alarm panel。
3. Send the
alarm information
to alarm center
Picture 9
1
Wed
Perimeter
4. When receiving the alarm signal, the alarm system will display the information
on LCD screen, which including alarm time, zone and type, etc.
Alarm software
Telephone Telephone Telephone Mobile
The second Tel The forth Tel The eighth Tel
PS
TN
alarm center
Send alarm signal to
Wireless DoorSensor
Wireless PIRDetector
Wireless SmokeSensor
Wireless GasSensor
RemoteController
EmergencyButton
11. .
Wait for the right times arrives,
you will hear a DI,
Call the phone number
that alarm panel connected
Input the user's code and
operate it as follows
Picture 12
X X X X X X #
di
[0][#]: [ 1][#]:
[2][#]: [3][#]:
[4 ][#]: [ 5][#]:
Exit Away Arm
Eliminate alarm & Disarm activate/disactivate spot siren
monitor spot Repeat the record
1
12. .
Wed
Perimeter
10. .13. .
14. .
15. .
16. .
17. .
18. .
19. .
20. .
21. .
22. .
1:
2:
3:
4:
Arm for first Timer
Disarm for first Timer
Arm for Second Timer
Disarm for Second Timer
1:
2:
Away Arm Zones List
Home Arm Zones List
1:
2:
3:
4:
5:
Alarm Delay
Arm Delay
Siren Duration
Ringing Times
Dialing Times
6. CID Timer Communication
1:
2:
Siren ON/ OFF
siren address code
1:
2:
Playback
Record
1
2:
3:
………………………
………………………
8:
:The 1 phone number
The 2 phone number
The 3 phone number
The 8 phone number
st
nd
rd
th
1 :
2 :
3 :
16:
01 zone attribute
02 zone attribute
03 zone attribute
16 zone attribute
………………………
………………………
“1” for Detectors
“2” for Remotecontroller
1:
2:
3:
………………………
………………………
16:
1 zone
2 zone
3 zone
16 zone
st
nd
rd
th
1:
2:
3:
……………………
……………………
8:
1 remote controller
2 remote controller
3 remote controller
8 remote controller
st
nd
rd
th
Clock
Timer
Zone
Attribute
Pin
Delay
Enroll
Siren
Report
Record/Playback
Set
Phone
Burglar
Perimeter
Duress
Panic
Fire
Gas
Medical
1:
2:
Report of CID alarm center
Report of Relay
23. .
24. .
CID Timer Communication
25. .
2481012 2 4 8 10
110 °
0
Planform
2
2.2m
10864
side view
Chart of parts
Detective distance
Working mode
Infrared sensor
Indicator
Tamper switch
ON/OFF
12V DC input
working mode1. Power saving mode,2. Standard Mode,3. Test mode
:
S
M
L
Light on
Light off
NOTE:Power saving mode: If the people enter the detective area and keepmoving continuously. The infrared detector sends one signal at firsttrigger only. The infrared detector won't send new signal whiletrigger after 10 seconds immovability.Standard mode: The Infrared detector sends the signal every 10seconds.Test mode: It is used to detect the infrared detective range only. Aslong as the human body moves in the detective range, the indicatorwill light on. It doesn't send the signal out.
26. .
temperature27 4030 (℃)0
8m
6m
Detective
distance
Temperature-compensating at stated time
Traditional temperature-compensating
3 4
5 6
2.2M
1 2
Assemble the universalblock with the universalball.
Fix the universal block on thewall by screw. It is suggestedto be installed aboveapproximately 2.2m.
Hitch the detector.
Avoid the places strong-interference, such asconditioner, fanner,refrigerator, oven,windows and so on.
Abstain from any objectslying in the front of thedetector's lens.
The antenna should be upturnedto insure the detective functionand wireless eradiated effect.
Hidden
areasform
edby
barriers
Barriers, su
chas
booksh
elves
The wireless PIR detector can detect the changeful temperature in full-
procedure and take on temperature-compensating at stated time
automatically. It avoid the defective of traditional compensate, also
help to abstain the influence caused by “close-body temperature's
effect”.
Installation & Usage
27. .
Usage
After the detector was mounted on the wall, turn the PIR switch to “ON”.
The indicator light flashes once every second. The detector enters in
blank situation. The indicator light stops flashing in 60 seconds, then the
detector works normally. The user can walk across the detective areas
temporality to observe whether LED lights on or not. Meanwhile, the
detector will eradiate wireless alarm signal to alarm system. The user
can adjust the installation angle to reach the best detective effect as
their requirement. When LED is ON, it means LED indicator is on. The
function of jumper for LED ON is just to control the LED indicator's
indication function. It will not affect the normal work situation.
NOTES:
1. Please install and use the detector as the manual's requirement.
Don't touch the exterior of sensor lest affect the sensitivity of detector. If
it need to be cleaned, please use the soft cloth wetting with alcohol to
wipe it off after turning power off.
2. Avoid the changeful environment.
3. This detector can reduce the occurrence of incidents, but without
design to foolproof all time. Besides using our products correctly as the
manual's description, please make sure you are trying to improve the
consciousness to keep away yourself from the unsafe incidents.
28. .
1. Instruction
Wireless door sensor matches with a magnet. It sends alarm signal to alarm
console when both parts seperated. The door sensor is designed in micro
power consumption with low power alert. The wireless transmitter adopts
SAWF. It is more stable. The transmitting
distance in open area can reach to 250m or more.
Magnet Door sensor
2. Installation
Remove the paper on double-faced glue on both door sensor and magnet.
Glue sensor and magnet in proper place you want. Be sure the antenna of
door sensor to be in uprightness (up or down).
3. Note
1. The magnet part is asked to be installed in mobile door or window. For
example, install magnet art on mobile place. And install sensor part on fixed
place.
2.The distance of both magnet part and sensor part is not beyond 10MM.
3. Please pull out the antenna to be sure the wireless transceiver effect.
4. Please replace the battery once you find out the Alarm/Low Power
Indicator is in red.
29. .
4. Component Diagram
21 3 4
1. Transmitting Code Jumper
2. Magnet:
3. Low Power Indicator:
4. Alarm Indicator:
: To change wireless code with jumper
place.
To match with sensor to perform alarm.
Red indicator for power lower.
Red indicator for alarm,
30. .
31. .
32. .
List for zone
Zone Type Remark
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Zone Type Remark
33. .
List for remote controller
No. User Remark
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
No. User Remark
34. .
35. .
36. .
P/N:350310000899E011V2.0