Upload
all4-inc
View
510
Download
2
Tags:
Embed Size (px)
Citation preview
CSMM 8 Implementation - Lesson Learned
Standards
ARIPPA 2010 Technical Symposium Harrisburg,
PA
August 25, 2010
Eric SwisherAll4 Inc.
2
Overview Background Implementation Process Lesson Learned
3
Background Continuous Source Monitoring Manual
(CSMM) Revision 8 Data Validation Requirements Reporting Format QA Activities
4
Implementation Process CEMDPS Access Migration Error Check Certification Activities QA/QC Activities
5
CEMDPS Access Continuous Emission Monitoring
System Data Processing System (CEMDPS)• GreenPort• Web-based portal in which all CEMS
related information will be submitted. Phase I (Monitoring Plan) Phase II Testing Phase III Certification
6
Migration Error Check Standards
• Facility Emission Standards Tracking
• Analyzer Information
7
Standards Streamlining
• “This condition also assures compliance with….”
25 Pa. Code §123.22(c)(4) [SO2] 25 Pa. Code §123.41 [Opacity] 40 CFR Part 60, Subpart Da
8
Standards Values Averaging Periods
9
Tracking Tracking
• Analyzer Type• Measurement Basis (units, wet/dry)• Manufacturer• Model No.• Full Scale Range• LMESE
10
LMESE Lowest Monitored Emission Standard
Equivalent (LMESE )• Lowest emission standard (i.e., lb/hr,
lb/MMBtu, etc.) in terms of the analyzer output (i.e., ppm)
• Used to determine daily zero/upscale calibration drift
100 x /LMESE|A-R| =CE
11
LMESE LMESE [PADEP Default = (FS) ÷ 2] No LMESE for:
• Opacity (Abs. Difference)• CO2 (Abs. Difference)
• O2 (Abs. Difference)• VFR (most cases 2.5% range)• Dual Range Analyzers?
12
Alternative LMESE VFR (FS Range = 150,000 scfm)
• No flow standard• Maintenance Limit = ≤ 3,750 scfm
(2.5% * 150,000 scfm)• OOC = ≤ 7,500 scfm
(5.0% * 150,000 scfm)• Alternative LMESE = 62,500 scfm
(3,750 scfm ÷ 6.0%)
13
Example CEMDPS Information
As Received
Parameter Units MAN MN FS LMESE
Flow scfm Teledyne 150 150,000 75,000
Corrected
Parameter Units MAN MN FS LMESE
Flow scfm Teledyne 150 150,000 62,500
14
Streamlined Alternative LMESE
NOX (LMESE = 120 ppm)• Maintenance Limit = ≤ 6 ppm
(5.0% * 120 ppm)• OOC = ≤ 12 ppm
(10.0% * 120 ppm)
15
Streamlined Alternative LMESE
NOX (Part 75 Span = 260 ppm)• Maintenance Limit = ≤ 6.5 ppm
(2.5% * 260 ppm)• OOC = ≤ 13 ppm
(5.0% * 260 ppm)• Streamlined LMESE = 130 ppm
(6.5 ppm ÷ 5.0%)
16
Example CEMDPS Information
As Received
Parameter Units MAN MN FS LMESE
NOX ppm TECO 43C 300 150
Part 75 Petitioned
Parameter Units MAN MN FS LMESE
NOX ppm TECO 43C 300 130
17
Certification Activities 7-Day Drift DAHS Verification Sample Reports QA/QC Plan
18
7-Day Drift Evaluates the accuracy and stability
of CMS calibrations over an extended period of unit operation
Revision 6 CEMS Uses the LMESE drift tolerances
19
DAHS Verification Certifies that the DAHS is functioning
correctly• Normal Operating Hours• Process Down Hours• Partial Operating Hours• Invalid Data Hours• Missing Data Hours
20
Sample Reports Submittal of sample data via CEMDPS
to ensure proper data format
21
QA/QC Activities Daily Calibrations Calibration Error Tests vs. Linearity
Tests Maintenance Activities Flow Monitor Leak Checks
22
Other Lessons Learned Refresher Training
23
Questions?
[email protected](610) 933-5246, extension
17
All4 Inc.2393 Kimberton Road
P.O. Box 299Kimberton, PA 19442
610.933.5246 x17
www.all4inc.com