1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ... -...

Preview:

Citation preview

MCAD-PLV-E5H-IP54

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A

B

C

D

E

F

G

H

J

K

L

M

B

C

D

E

F

G

H

J

K

L

M

A

CRITICAL CHARACTERISTICSKEY CHARATERISTICSINSPECTIONMUST COMPLY TO ROHS DIRECTIVE 2011/65/EU

600.023.62[ ]

400.015.75[ ]

100.03.94[ ]

2001.078.78[ ]2156.0

84.88[ ]

686.827.04[ ]

769.830.31[ ]

852.833.58[ ]

935.836.84[ ]

1018.840.11[ ]

1101.843.38[ ]

74.52.93[ ]

674.026.54[ ]

806.531.75[ ]

896.535.30[ ]

304.111.97[ ]

384.715.14[ ]

1024.040.32[ ]

1328.252.29[ ]

261.010.28[ ]

414.816.33[ ]

160.06.30[ ]

185.07.28[ ]

1991.978.42[ ]

2026.979.80[ ]

273.010.75[ ]

315.012.40[ ]

357.014.06[ ]

568.822.39[ ]

613.224.14[ ]

145.05.71[ ]

255.010.04[ ]

365.014.37[ ]

513.520.22[ ]

939.536.99[ ]

427.016.81[ ]

426.016.77[ ]

50.01.97[ ]

69.52.74[ ]

17.00.67[ ]

40.01.57[ ]

13.50.53[ ]

19.50.77[ ]

218.58.60[ ]

298.511.75[ ]

378.514.90[ ]

1276.550.26[ ]

1533.560.37[ ]

296.011.65[ ]

250.09.84[ ]

43.01.69[ ]

45.01.77[ ]22.5

0.89[ ]

19.50.77[ ]

1 OF 3132R0268

CONFIDENTIAL: PROPERTY OF DANFOSS A/S NORDBORG, DENMARK. NOT TO BE HANDED OVER TO BE COPIED OR BE USED BY A THIRD PARTY. TWO OR THREE DIMENSIONAL REPRODUCTION OF CONTENTS TO BE AUTHORIZED BY DANFOSS A/S.

SHEETMODEL132R0268

REVDRAWING NUMBER

E3H CONTACTOR + FUSIBLE DISCONNECTORFEB-12-19Lauri

CHECKED

MAY-29-19SABARISH

DESIGNED

CHANGED

NOT VALID WITHOUT FROZEN DATE IN ID STAMP

DESCRIPTION

FINISHA10.150

INTERPRET DIM. & TOL. PER ASME Y14.5M-1994ALL DIMENSIONS ARE IN MILLIMETERS

TOLERANCES UNLESS OTHERWISE SPECIFIED.X�#�1.0 .XX�#�0.50 �a��#�1.0

MATERIALSIZESCALETHIRD ANGLE PROJECTION

002

NOTE:1.BACK CHANNEL COOLING: BOTTOM IN TOP OUT2.CABLE FEED: BOTTOM ENTRY & BOTTOM OUT3.PLINTH HEIGHT CAN BE OF100,200, & 400mm HEIGHT.

CONTACTOR

GROUND TERMINAL

DC - TERMINAL

MOTOR TERMINAL

MAINS INPUT

REFER NOTE 3

CONTROL COMPARTMENT DOORIS NOT SHOWN IN THE DRAWINGFOR SHOWING INTERNAL COMPONENTSIN CONTROL COMPARTMENTONLY CONTROL COMPARTMENT UNITIS SHOWN FOR BETTER CLARITY

CONTROL COMPARTMENTTERMINAL

SEE DETAIL

SEE DETAIL

MAINS INPUT6X DETAIL BSCALE 0.300

SEE DETAIL C

6X DETAIL CSCALE 0.300

-FUSDISCON-CONTACTER

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A

B

C

D

E

F

G

H

J

K

L

M

B

C

D

E

F

G

H

J

K

L

M

A

225.08.86[ ]

474.018.66[ ]

1093.043.03[ ]

377.014.84[ ]

30.01.18[ ]

33.01.30[ ]

55.02.17[ ]

2X 555.021.85[ ]

45.51.79[ ]

588.023.15[ ]

2 OF 3132R0268SHEETMODEL

132R0268REVDRAWING NUMBER

002

COOLING CLEARANCESEE DETAIL A

AIR OUTLETTOP

AIR OUTLET

AIR INLET

AIR INLET BOTTOM

SECTION A-A

PLACE OF CONDUITS FOR MOTOR

8X DETAIL ASCALE 1.000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A

B

C

D

E

F

G

H

J

K

L

M

B

C

D

E

F

G

H

J

K

L

M

A

134.0�$� 134.0�$�

696.827.43[ ]

407.516.04[ ]

82.93.26[ ]

173.76.84[ ]

2014.279.30[ ]

995.439.19[ ]

3 OF 3132R0268SHEETMODEL

132R0268REVDRAWING NUMBER

002

Recommended