  • 36 69kV

    31

    6699kkVV

    Protective Relay

    CTPT

    DC

    (345kV/161kV)

    (161kV/69kV)

    (161kV/11.95kV-22.8kV)

    11.95kV-22.8kV/110V-220V

    1

    P/S

    69kV

    69kV/11.95kV

  • 69kV 36

    32

    () 1.()() 0.7 (42 )

    2.Normal Inverse Type

    3. GPT 4. 10MVA87T 161KV

    5.

    51Z 6.345kV161kV 69kV GIS

    87B 6

    7. CT CT 20 10%

    () 1. ANSI/IEEE Std 242-1986 0.2 0.5 0.3

    2.

    3.;

    4.

    5.

    6.69KV

    1

  • 36 69kV

    33

    ()

    23.9kV 11.4kV

    5151N

    15

    23.9kV 11.4kV

    5151N

    25

    23.9kV 11.4kV

    5151N

    35

    69kV

    5151N

    51:42

    51N:10

    23.9kV 11.4kV

    51Z 55

    2

    ()

    (Magniude Relay)

    ()

    ()

    1. 11.95kV23.9 kV

    2. 69 kV

    ;

    34

    3

    4 T

    ()

    1.

    (1)

    (2) CTI

  • 69kV 36

    34

    (3) CTI

    2.(Coordination Time

    IntervalCTI) (1) (2) (3) (4)

    (5) 0.3~0.5

    (6) ANSI CTI 0.2 ~0.5

    0.3

    0.3 TBack-upTMain+0.3 TBack-up TMain

    5

    3. (1) CB6

    6 A. : Ry3 B. : Ry2 Ry1

    (2) CB4 CB5

    6 A.: Ry2 B.: Ry1

    (3) 0.3

    TRy2= TRy3+0.3 TRy1= TRy2+0.3

    6

    Tap

    Level

    10.7%

    ()#750(#1MTR)#760 (#2MTR)

    1. CTR IFL125 MVA /1.732 69 kV

    = 209.19A 209.19 1.5 = 313.8A

    CT.Ratio 400/5---Y 2. CTR IFL225 MVA /1.732 11.95 kV

    = 1207.88A 1207.88 1.5 = 1811.8A

    CT.Ratio 2000/5--- 3.50/51

    (1)51 Tap

    51 209.19/(400/5)=2.61A 2.61A *1.25~1.5 =3.92A 51 Tap 40.8In

  • 36 69kV

    35

    (2)51 Level 51 1173/(400/5)/4 =3.66 SPAJ140CABBLevel = 0.13 51SPAJ140C T/L = 4/0.13

    (3)50 50 209.19/(400/5)10~15= 30A 50SPAJ140C 30A6In

    4. 87T (1) CAABB (2)

    a.400/5---Y

    b.2000/5---

    (3) IH = 209.19 /400/5= 2.6148A IL = 1207.881.732 /2000/5=

    5.229A IL / IH = 5.229 / 2.6148 =1.9997A (4)

    TL / TH = 10 / 5 = 2 CAABBTap 55.56.67.38910 Tap 5, TH=5 Tap 10, TL=10 87T CAABB5/10, Level =1.0

    (5)Mismatch

    M=IL/IH-TL/TH/ S* 100% IH , IL

    TH ,TL

    S IL/IH TL/TH M% =2.0-1.9997/ 1.9997* 100%= 0.015% M%+ %=35%

    ()11.95 kV 1. 51Z 51Z 7000A 1000/551Z 55 51Z Level 7000A(1000/5)2=17.5 55 CO-8(ABB) Level=550

    2. 51 (1)51 Tap

    51 1208/2000/5=3.02A 3.02A *1.25~1.5 =4.53A 51 Tap 40.8In

    (2)51/51N Level 51 6613/2000/5/4 =4.13 SEL351SEL Level = 1.7(V.I) 51SEL351 T/L = 4/1.7 51N 7000/2000/5/4 =11.7 SEL351SEL

    Level = 4.5(V.I) 51SEL351 T/L = 4/4.5 50/50N

  • 69kV 36

    36

    ()69kV #750-#1MTR#760-#2MTR 11.95kV 1.PF 1(Power Fuse 1)200Tie

    7 PF1

    2.PF1 #750-#1MTR 200Tie F#11 #760

    8 PF1

  • 36 69kV

    37

    3.PF2(Power Fuse2)200Tie

    9 PF2

    4.PF2 #760-#2MTR 200Tie F#12 #750

    10 PF2

  • 69kV 36

    38

    ()69kV P/S#1S/S#2S/S#3S/S#750-#1MTR

    1.#750-51N 200Tie

    11 #3S/S #750-#1MTR

    2.#750-51N 200Tie

    12 #3S/S #750-#1MTR

  • 36 69kV

    39

    3. P/S #620-51N

    13 P/S #620-51N

    4. P/S #620-51N P/S #1MTr.-#750 N-1

    14 P/S #620-51N

  • 69kV 36

    40

    5. P/S #620-51N P/S #2MTr.-#760 N-1

    15 P/S #620-51N

    ()69kV P/S #4S/S#5S/S #760-#2MTr. 1.#5S/S #760-51N 200Tie

    16 #5S/S #760-51N

  • 36 69kV

    41

    2. #4S/S #610-51N P/S #640 N-1

    17 #4S/S #610-51N

    3.#4S/S #610-51N P/S #630 N-1

    18 #4S/S #610-51N

  • 69kV 36

    42

    4. P/S #630 51N

    19 P/S #630 51N

    5. P/S #630 51N P/S #750 N-1

    20 P/S #630

  • 36 69kV

    43

    6. P/S #630 51N P/S #760 N-1

    21 P/S #630

    ()69kV #750-#1MTR #760-#2MTR 1.PF1(Power Fuse 1)200Tie

    22 PF1

  • 69kV 36

    44

    2. PF1 #3S/S #750-#1MTR N-1F#11 200Tie

    23 PF1

    3.PF2(Power Fuse2)200Tie

    24 PF2

  • 36 69kV

    45

    4.PF2 #5S/S #760-#2MTR N-1F#12 200Tie

    25 PF2

    ()69kV P/S#1S/S#2S/S#3S/S #750-#1MTR 1.#750-51 200Tie

    26 #3S/S #750-#1MTR

  • 69kV 36

    46

    2.#2S/S #630-51

    27 #2S/S #630

    3.#1S/S #620-51

    28 #1S/S #620

  • 36 69kV

    47

    4. P/S #620-51

    29 P/S #620

    5. P/S #620-51 P/S #2Mtr.-#760 N-1

    30 P/S #620

  • 69kV 36

    48

    6. P/S #620-51 P/S #1Mtr.-#750 N-1

    31 P/S #620

    ()69kV P/S#4S/S#5S/S #760-#2MTR 1.#760-51 200Tie

    32 #5S/S #760-#2MTR

  • 36 69kV

    49

    2.#4S/S #610-51 P/S #640 N-1

    33 #4S/S #610

    3.#4S/S #610-51 P/S #630 N-1

    34 #4S/S #610

  • 69kV 36

    50

    4. P/S #630 -51

    35 P/S #630

    5. P/S #630 -51 P/S#2Mtr.-#760 N-1

    36 P/S #630

  • 36 69kV

    51

    6. P/S #630 51 P/S#1Mtr.-#750 N-1

    37 P/S #630

    ()

    () 69kV

    C.P.T

    Tap Level IIT

    50/51 7.0 4.5 NI 1

    P/S#1MTr.161/69/11kV

    #750 50N/51NCO-8 ABB 0~12A 2000/5

    1.5 2 NI

    50/51 7.0 4.5 NI 2

    P/S#2MTr.161/69/11kV

    #760 50N/51NCO-8 ABB 0~12A 2000/5

    1.5 2 NI

    50/51 7.0 4 NI 3

    # P/S #600Tie 50N/51N

    CO-8 ABB 0~12A 2000/5 1.0 4 NI

    4 P/S#1MTr.161/69/11kV#1750~#750

    51NT CO-8 ABB 0~12A 1200/5 1.5 5.5 NI

    5 P/S#2MTr.161/69/11kV#1760~#760

    51NT CO-8 ABB 0~12A 1200/5 1.5 5.5 NI

    50/51 5=1In 0.49 NI 6

    # P/S #620 50N/51N

    SEL- 311L SEL 0~12A 2000/5 1=0.2In 0.48 NI

    50/51 5=1In 0.54 NI 7 #1S/S #610

    50N/51N

    SEL- 311L SEL 0~12A 1200/5 1.5=0.3In 0.42 NI

    50/51 5=1In 0.48 NI 8 #1S/S #620

    50N/51N

    GRL- 711P TOSHIBA 0~12A 1000/5 1.5=0.3In 0.38 NI

    50/51 5=1In 0.38 NI 9 #2S/S #620

    50N/51N

    GRL- 711P TOSHIBA 0~12A 1000/5 1.5=0.3In 0.29 NI

    50/51 5=1In 0.28 NI 10 #2S/S #630

    50N/51N

    GRL- 711P TOSHIBA 0~12A 1000/5 1.5=0.3In 0.2 NI

    50/51 5=1In 0.18 NI 11 #3S/S #630

    50N/51N

    GRL- 711P TOSHIBA 0~12A 1000/5 0.5=0.1In 0.18 NI

    50/51 4=0.8In 0.13 30 NI 12 #3S/S #750-#1MTR

    50N/51NSPAJ140C ABB 0~12A 400/5

    0.5=0.1In 0.05 10 NI

    50/51 5=1In 0.22 NI 13

    # P/S #630 50N/51N

    SEL- 311L SEL 0~12A 2000/5 1=0.2In 0.24 NI

    50/51 5=1In 0.22 NI 14

    # P/S #640 50N/51N

    SEL- 311L SEL 0~12A 2000/5 1=0.2In 0.24 NI

    67 5=1In 0.05 NI 15 #4S/S #630

    67N

    SEL- 311L SEL 0~12A 1200/5 1=0.3In 0.05 NI

    67 5=1In 0.05 NI 16 #4S/S #640

    67N

    SEL- 311L SEL 0~12A 1200/5 1=0.3In 0.05 NI

    50/51 5=1In 0.24 NI 17 #4S/S #610

    50N/51NGRL-711P TOSHIBA 0~12A 800/5

    1.5=0.3In 0.21 NI

    50/51 5=1In 0.15 NI 18 #5S/S #620

    50N/51NGRL-711P TOSHIBA 0~12A 800/5

    0.5=0.1In 0.18 NI

    50/51 4=0.8In 0.13 30 NI 19 #5S/S #760-#2MTR

    50N/51NSPAJ140C ABB 0~12A 400/5

    0.5=0.1In 0.05 10 NI

    38

  • 69kV 36

    52

    11.95kV

    C.P.T

    Tap Level IIT

    1 #3S/S

    #750#110#1MTR

    51Z CO7 ABB 0~12A 1000/5 2 5 NI

    2 #5S/S

    #760#120#2MTR

    51Z CO7 ABB 0~12A 1000/5 2 5 NI

    50/51 4=0.8In 1.7 VI3

    #750#11011.95kV

    50N/51N

    SEL351 SEL 0~12A 2000/51.5=0.3

    In 4.5 VI

    50/51 4=0.8In 1.7 VI4

    #760 #12011.95kV

    50N/51N

    SEL351 SEL 0~12A 2000/51.5=0.3

    In 4.5 VI

    50/51 5=1In 0.7 VI5

    #110~#120BUS

    200Tie 50N/51NSEL351 SEL 0~12A 2000/5

    1.5=0.3In 2.8 VI

    50/51 5=1In 2.5 14In EI6

    F#11#11011.95kV

    50N/51N

    SEL351 SEL 0~12A 600/51.5=0.3

    In 5 EI

    50/51 5=1In 2.5 14In EI7

    F#12#12011.95kV

    50N/51N

    SEL351 SEL 0~12A 600/51.5=0.3

    In 5 EI

    8 PF1 POWERFUSE PF125E

    9 PF2 POWERFUSE PF125E

    [1] J.L.Blackburn . Applied Protective Relaying