ADVIGANO
Explosion ProofElectrical Equipment
ATX MARINA ENCLOSURES
Zone 1 & 2 - 21 & 22
EEx e II/EEx eia or eib IIC T3 to T6 IP66 IK10
ATEX IEC EC II 2G/D
0964 65 0964 72
Black polyester enclosures• Protective flange: one at the top and one at the bottom• Interchangeable, padlockable locks• Fasten with plastic double bar locks. Supplied with a key.• 4 fixing lugs supplied. Doors mounted on hingesEnclosures with plain door
Volume
(dm3)
25
51
80
190
313
Volume
(dm3)
51
80
External dimensions
Ht/Width/Depth (mm)
400 x 300 x 200
500 x 400 x 200
600 x 400 x 250
800 x 600 x 300
1000 x 800 x 300
Dimensions
(mm)
350 x 250
450 x 350
550 x 350
750 x 550
950 x 750
Lenght
(mm)
337
437
537
737
937
Crosspiece width
(in mm)
243
343
543
743
External dimensions
Ht/Width/Depth (mm)
500 x 400 x 200
600 x 400 x 250
Lower
aperture
No (2)
Yes (1) (3)
Yes (1) (3)
No
No
Lower
aperture
Yes
Yes
Weight
(Kg)
4.8
6.2
7.7
18.3
23.6
Weight
(Kg)
1.2
1.1
1.5
3
5.5
Weight
(Kg)
6.4
8.5
No. of
door apertures
3 (2)
4 (2)
Size
1
2
3
4
5
For enclosure
(ht. x width in mm)
400 x 300
500 x 400
600 x 400
800 x 600
1000 x 800
For enclosure
(height in mm)
400
500
600
800
1000
For enclosure
(width in mm)
300
400
600
800Cat. number
0959 57
0964 73
0964 74
405
828
1028
305
618
818
200
300
300
215
315
315
326
658
858
180
280
280
336
768
968
External dimension (mm) Fitting
Size
2
3
Cat. No.
0959 57
0964 65
0964 71
0964 73
0964 74
Cat. No.
0964 52
0964 53
0964 54
0964 55
0964 56
Cat. No.
0964 75
0964 76
0964 77
0964 78
0964 79
Cat. No.
0964 81
0964 82
0964 83
096484
Cat. No.
0964 66
0964 72
1
1
1
1
1
Pack.
1
1
1
1
1
Pack.
5
5
5
5
5
Pack.
10
10
10
10
Pack.
1
1
Pack.
(1) For plate 114 x 322 (Cat. No. 0964 85 or 0964 86)(2) On request: aperture for plate 130 x 264 (Cat. No. 0964 90)(3) On request: without lower aperture
Enclosures with door apertures
(2) For plate 130 x 264
Accessories“Telemecanic” perforated plate (zinc bichromate)
Set of 2 uprights
Crosspieces
0964 65/66
0959 57 - 0964 73/74
0964 71/72
TECHNICAL DATAZones :• 1 and 2 and 21 - 22Classification :• According to CENELEC- Conforming to ATEX Directive 94/9 EC and standards EN 50014-
19-20- EC 0081 II 2 G for gas EEx e II/EEx eia or eib IIC/EEx ia or ib IIC- T3 to T6 depending on the components installed in the enclosure- EC 0081 II 2 D T = 85°C for dust• According to IEC- Conforming to standards IEC 60079-0/7/11- Ex e II/Ex eia or eib IIC/EX ia or ib IIC- T3 to T6 depending on the components installed in the enclosureCertification :- Type CAe- CENELEC LCIE 02 ATEX 6248X- IEC LCIE Ex 02.032X- declaration of conformity No. 50201- Conforming to standard EN 50281-1-1 “combustible dust”Protection index :• IP66 according to EN 60529 and IEC 60529• IK10 mechanical resistance according to EN 50102Operating temperature : – 40°C to + 55°CDimensions (mm) :
195
COVER PLATES ATX “MARINA” ENCLOSURES
Zone 1 & 2 - 21 & 22
EEx e II/EEx eia or eib IIC T3 to T6 IP66 IK10
ATEX IEC EC II 2G/D
ADVIGANO
Explosion ProofElectrical Equipment
0964 89
0964 85
Example of earth continuity
0964 90
TECHNICAL DATAZones : 1 and 2 and 21 - 22Classification :• According to CENELEC :– Conforming to ATEX Directive 94/9 EC and standards EN 50014-19-20– EC 0081 II 2 G : for gas EEx e II/EEx eia or eib IIC/EEx ia or ib IICT3 to T6 depending on the components installed in the enclosure– EC 0081 II 2 D T = 85°C: for dust• According to IEC :– Conforming to standards IEC 60079-0/7/11 Ex e II/Ex eia or eib IIC/Ex ia or ib IIC T3 to T6 depending on the components installed in the enclosureCertification :• Approved type CAe• CENELEC LCIE 02 ATEX 6248X• IEC LCIE Ex 02.032X• declaration of conformity No. 50201• Conforming to standard EN 50281-1-1 (combustible dust)Protection index :• IP66 according to EN 60529 and IEC 60529; IK10 mechanical resistance (EN 50102)Operating temperature : - 40°C to + 55°CDimensions (mm) :Front plates :
264
13
0
264
13
0
2
322
11
4
14
264
13
0
264
13
0
0964 90
0964 87 - 0964 88
0964 85
Cable entry plates:
0964 95
0964 89
0964 86
0966 99
Cable entry plates• Black polyester. Supplied with fixing screwsPlain plate (Drilled on request)
Front plates for mounting on the door• Black polyester. Supplied with fixing screwsPlain plate
Volume
(dm3)
1.3
1.4
Volume
(dm3)
0.4
Volume
1.2
1.2
1.2
0.8
0.8
1.2
1.2
1.4
Weight
(Kg)
0.3
0.4
Weight
(Kg)
0.1
Weight
0.4
0.4
0.4
0.3
0.3
0.4
0.4
0.3
Plate 130 x 264
Plate 114 x 322
Plastic blanking plug
for Ø 30 holes designed
for buttons - rotary head and indicator
(Drilled on request)
17 clearance holes for M20 0.3
and 3 holes for M25
Cat. No.
0964 90
0964 85
Cat. No.
0983 38
Cat. No.
0964 90
0966 99
0964 99
0964 87
0964 88
0964 95
0964 89
0964 86
1
1
Pack.
1
Pack.
1
Pack.
1
1
1
1
1
1
1
Pre-drilled plate (For cable gland)
Accessories
Pre-drilled plate with 2 double holes• Fixed on one of the enclosure’s central aperturesFor 2 double pole RCBOs
Pre-drilled plate with 2 holes• Fixed on one of the enclosure’s central aperturesFor 2 triple-pole or 4-pole MCBs
Pre-drilled plate with 4 holes for actuatorFor 4 push-buttons or indicators, and 1 flush-mounting socket outlet16 A - 3P+E/3P + N+E, or 16 A 2P + E (with adaptor Cat. No.For 4 push-buttons or indicators, and 1 hole for flush-mounting socket outlet32 A - 2 P + E/3 P + E/3 P + N + ENote: actuator for fixing on vertical DIN rails
Pre-drilled plate with 5 holes for actuatorFor push-buttons or indicators
Pre-drilled plate with 3 holes Ø 30For 4-pole switch, 16 A switch, indicator, single pole changeover switch,push-button, double pole MCBNote: (1) rotary actuator, use the heads designed for vertical DIN railsNote: (2) for double pole MCB must be mounted on the central aperture
For special options, please consult us• Earth continuity plates all size drilled followingspecification
196
COMPONENTS FOR MOUNTING ON ATX “MARINA” AND STAINLESS STEEL ENCLOSURE DOORS
Zone 1 & 2 - 21 & 22
EEx e II /EEx de IIC IP66
ATEX CEI UL II 2G/D
ADVIGANO
Explosion ProofElectrical Equipment
0983 00 0983 03 0983 35 0981 10
Control and indicators for mounting on enclosure doorActuators are supplied with seal, special nut and keyPush-buttons
Volume
(dm3)
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.17
0.18
Volume
(dm3)
0.18
0.18
0.18
0.18
0.18
Volume
(dm3)
0.18
0.18
0.18
Volume
(dm3)
0.18
0.18
0.18
Weight
(Kg)
0.05
0.05
0.05
0.05
0.05
0.07
0.07
0.07
0.07
Weight
(Kg)
0.03
0.03
0.03
0.03
0.03
Weight
(Kg)
0.09
0.09
0.09
Weight
(Kg)
0.09
0.09
0.09
Push-button supplied with 4
red, green, yellow and white inserts
Spring-return red
mushroom head push-button
Spring-return black
mushroom head push-button
Red “EMERGENCY STOP”
key* switch mushroom head
Red “EMERGENCY STOP”
push-pull mushroom head
Key* switch button, key removed
in off and on button position
Key* switch button key removed
in on position
Key switch button * 0 - 1 key removed
in position 0
Blanking plug
2 positions 0 - I latching
3 positions I - 0 - II
(I and II latching)
3 positions I - 0 - II
(I and II automatic return)
3 positions I - 0 - II
with automatic return from II to 0
3 positions I - 0 - II
with automatic return from I to 0
2 NO contacts
2 NC contacts
C/O contact
2 NO contacts
2 NC contacts
C/O contact
Cat. No.
0983 00
0985 01
0983 01
0983 02
0983 03
0983 20
0983 21
0983 22
0983 38
Cat. No.
0983 24
0983 34
0983 35
0983 36
0983 37
Cat. No.
0981 10
0981 11
0981 12
Cat. No.
0981 20
0981 21
0981 22
1
1
1
1
1
1
1
1
5
Pack.
1
1
1
1
1
Pack.
1
1
1
Pack.
1
1
1
Pack.
Black selector switches
Contact components for door mounting• Connection via 2 x 2.5 mm² terminals
Contact components with sealed cableImportant: suitable for mounting on non Ex enclosure• supplied with 3 m of cable 2 x 0.75 mm²
TECHNICAL DATAZones : 1 and 2 and 21 - 22Actuators, contact and indicators• Approved type : AUX• According to CENELEC : 0081 II2 G/D EEx ed II (actuator)
EEx ed IIC (actuator)LCIE: 00 ATEX 0002 U• According to IEC : Ex ed II(actuator) - Eex de IIC (comtact)LCIE: Ex 00.012 U• According to UL : AEX e IIUL : E 214068Operating temperature : - 50°C to + 60°C (ATEX - IEC); - 35°C to + 60°C (UL)Protection index IP66 (for actuators, indicators switch handles)Contact components :Reference insulation voltage 690 VReference operating voltage 250 V, 250 V, 110 V, 24 V, 230 VCategory of use AC 12, AC 15, DC 13, DC 13Rated operating current 16 A, 10 A, 0.5 A, 1 A, 10 ARated current Ithe 16 A / + 40°C, 11 A / + 60°CContact materials : Ag Sh 02Number of operations : 106 for the contactsOperational life : 105 hours for the indicatorsConnection to terminals : 2.5 mm2Operating temperature : - 50°C to + 60°CDimensions (mm) :
0983 00
0983 20/21/22 0983 38
0983 23/24/30/31/32/33/34/35/36/37
0985 01 - 0983 01/02/03
20 20
5
5
5
2020
20
13
13
27.5
18
38
38
38
4038
38
197
COMPONENTS FOR MOUNTING ON ATX “MARINA” AND STAINLESS STEEL ENCLOSURE DOORS
Zone 1 & 2 - 21 & 22
EEx e II ou EEx de IIC
ATEX CEI II 2G/D ou II 2 G
ADVIGANO
Explosion ProofElectrical Equipment
0982 11 0982 21 0988 53 0988 21
Changeover switch for mounting on a vertical and
horizontal rail• Connection via 2 x 2.5 mm² terminals
Single pole I - II
(Switch handle 0988 51 not supplied)
Single pole with stop I - 0 - II
(Switch handle 0988 51 not supplied)
16 A switchDouble pole I - II (handle 0986 58 not supplied)
Padlockable handle for selector switch, changeover switch
and 16 A switchSupplied with fixing base
4-pole control and load break switches(switch handle 0986 66 not supplied
Control switch 4 NO - 2 positions
Control switch 2 NO + 2 NC - 2 positions
Control switch 1 NC + 3 NO - 2 positions
Control switch 3 NC + 1 NO - 2 positions
Control switch 1 NO - 4 positions
Control switch with 3 positions
Control switch with 3 positions
Control switch with 3 positions
with automatic return from II to I
Control switch with 3 positions
with automatic return from II to 0
Control switch with 5 positions
Load break switch 4 NO - 2 positions
Load break switch 3 NO + 1 NC - 2 positions
Rotary switch handle for 4 pole switch- Supplied with fixing base for mounting on door
- Can be used for any of the 4 pole switch functions
Signalling components, switch handles and contact blocksIndicators:• Mounting on door (supplied with coloured indicator lens)Multi LED AC 24V, 48V, 110V, DC 24V, 48V- Equipped either with a terminal block (clamping capacity twice 2 x 2.5 mm²) or with a cable outlet (3 m, 2 x 0.75 mm²) suitable for mounting on non Ex enclosure for cable outlets
Red indicator
Green indicator
White indicator
Yellow indicator
Blue indicator
Volume (dm³)
0.10
0.10
0.10
0.10
0.10
Weight (Kg)
0.10
0.10
0.10
0.10
0.10
0982 21
0982 22
0982 20
0982 24
0982 23
Cat. No
0982 11
0982 12
0982 10
0982 14
0982 13
Cat. No
0988 53
0988 54
1
1
0.4
0.4
0.2
0.2
0988 55 1
0988 51 10.40.09
0986 66 1
0988 21
0988 22
0988 23
0988 24
0988 25
0988 26
0988 27
0988 28
0988 29
0988 30
0988 31
0988 32
1
1
1
1
1
1
1
1
1
1
1
1
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
1
1
1
1
1
Pack.
TECHNICAL DATA• Components conforming to Directive 94/9 EC, standardsEN 50014/18/19/28• Contact and indicating componentsZones : 1 and 2 and 21 - 22• Approved type : AUX• According to CENELEC: 0081 II2 G/D EEx ed IIC or EEx e IILCIE: 00 ATEX 0002 U• According to IEC: Ex ed IIC or Ex e IILCIE: Ex 00.012 U• According to UL : AEX ed IIC or AEX e IIUL: E 214068• Selector switches, changeover switches and 16 A switchesZones 1 & 2 are authorised in an approved dustproof enclosure• Approved type : 8008/2• According to CENELEC: II2 G EEx de IIC T6PTB 00 ATEX 1111 UOperating temperature : - 55°C to + 40°C• 4-pole control and load break switchesZones 1 & 2 are authorised in an approved dustproof enclosure• Approved type : 07-3331-1...• According to CENELEC: II2 G EEx de IIC T6PTB 99 ATEX 1043 UOperating temperature: - 50°C to + 60°C• According to ULUL: E 184198Operating temperature : - 35°C to + 60°C• Padlockable handle (0986 58)• Approved type : AUXe• 03 ATEX 0012U (CENELEC)• Ex 03.011U (IEC)Protection index :• IP66 (for actuators, indicators units and switch handles)Dimensions (mm) :
0982 10/11/12/13/14
57.5
46
52
91
33.5
198
ADVIGANO
Explosion ProofElectrical Equipment
TECHNICAL DATA• IndicatorsReference insulation voltage : 300 VReference operating voltage : AC 24 V, 48 V, 110 V, 230 V
DC 24 V, 48 VConsumption : 1 WIndicators : multi LED• Single pole and double pole changeover selector switchBreaking capacity(according to AC 15/DC 13)240 V ~6 A 415 V ~5 A 660 V ~2.5 A380 V ~6 A 500 V ~4 A• Double pole 16 A switchInsulation voltage 750 VOperating voltage 690 V 415 VMaximum current 16 A 16 ACategory of use AC-1 AC-15• 4-pole control and load break switches• Electrical characteristics Control breaking capacityInsulation voltage (auxiliary on/off switch)Ui/660 V Ie/AC 15 400 V 10 AUe/400 V Ie/AC 12 400 V 16 A
Ie/DC 13 24 V 1AIthe 16A
• Nominal resistance to overvoltageUimp/6 KV• Short-circuit current Load breaking capacityat 400 V DIN EN 60947-3Ie/4 KA (main switch, motor control)• Short-circuit current P/AC 3/AC 23(max. power fuse NHgL) 230 V 3ph/3KW 1ph/2.2KW16 A 400 V 3ph/5.5KW 1ph/3KW• Rated thermal current le/AC 3/AC 23(+ 40°C) Ithe /16 A 400 V 11A(+ 60°C) Ithe /11 A• Ammeter1 max. 500 V, Fg 25 at 100 Hz, overload 1V In 5 secondsAccuracy class 1.5, consumption 0.7 VA at In,insulation 3 KV - 50 Hz 1 mn• Connection diagrams for contact components:
14 24
13 23
45°45° 135°135°
13 - 14
23 - 24
0 1
0981 00
0988 55
0988 53 0988 54
0981 01 0981 02
• Connection diagrams for changeover selector switch:
Connection diagrams: 4 pole switches
• Connection diagrams for 16 A double pole switch:
-
-
-
-
098832
098831
098830
098829
098828
098827
098826
098825
098824
098823
098822
098821
I0
2X
1
4X
6X
12
X3 5 11 0 I
24
1 3
612
5 11
0I X
2
1
X4
X6
3 5
X14
13 0 I
2 4
1 3
6 14
513
II
I0
13
14
X23
24
X33
X34
43
44
III 0
14
13
24
23
4434
33 43
IV14 24 34
X44
IIIII
I0
X
13
X
23
X
33 43
2414
III0
I IIIV
13 23
34 44
33 43
III
0
12
11X
X
24
23
X34
33
44X
430 I II
12
11
24
23
4434
33 43
II
0I
X14
13
X24
23
32
X31
42
X41
0 I II
14
13
24
23
32
31
42
41
0II
I
14
X13
24
23X
X34
33
X44
43I 0 II
2313
14 24 44
33 43
34
IIIIII
12
011X
24
X
34
XX44
23 33 430
I II
12 24
III
11 23
4434
33 43
I0
12
11X
22 32
21X
31X
X44
43 0 I
11 21 31 43
14 24 34 44I0
13X
23
X
33
X
43
X
14 24
0 I
13 23
34 44
33 43
I0
13
X
23
X
31X
41X
0 I
14 24
13 23
32 42
31 41
14I0
X
13
3424 44X
23
X
33
X
43
14 24
13 23
34 44
33 43
X
14 24 32 42
0 I
14
51
73
60
D
48
4,5 B
A
C
2 Ø
Dimensions (mm) :
0988 21 to 32
0986 52/53/5412
20
5
52
27.5
55
38
0986 58
(without fixing base)
(without fixing base)
0986 47/48
>
TECHNICAL DATAZones : 1 and 2• Components conforming to Directive 94/9 EC, standardsEN 50014/18/19/2 and standards IEC 60079-0/1/7/18• 20 A switch• Approved type: IT20• According to CENELEC: 0081 II2 G EEx de IIC - LCIE: 03 ATEX 0010 U• According to IEC : Ex de IIC - LCIE: Ex 03.008 U• Operating temperature - 20°C to + 40°C• Padlockable handle• Approved type: AUXe• According to CENELEC: 0081 II2 G/D EExe II - LCIE: 03 ATEX 0012 U• According to IEC: Exe II - LCIE: Ex 03.011 U• Operating temperature - 20°C to + 40°C• AmmetersZones : 1 & 2 authorised in an approved dustproof enclosure• Approved type: C 48 D• According to CENELEC: 0081 II2 G EEx em II T6 - LCIE: 02 ATEX 0006 U• According to IEC : Ex em II - LCIE: Ex 02.019 U• Operating temperature -25°C to +55°C• Fuse carrier• Approved type: FU40• According to CENELEC: 0081 II2 G EEx de IIC - LCIE: 02 ATEX 0003 U• According to IEC: Ex de IIC - LCIE: Ex 02.021 U• Operating temperature - 20°C to + 40°CDial for ammeter :
199
COMPONENTS FOR ATX “MARINA” AND 316 L STAINLESS STEEL ENCLOSURES
ADVIGANO
Explosion ProofElectrical Equipment
2 x 20 A
3 x 20 A
4 x 20 A
Window 48 x 48
16 A max. for gG cartridges
40 A max. for aM cartridge
For 1 A C.T. 0-1-3 Flc
For 1 A C.T. 0-1-5 Flc
For 1 A C.T. 0-1-6 Flc
For 5 A C.T. 0-1-3 Flc
For 5 A C.T. 0-1-5 Flc
For 5 A C.T. 0-1-6 Flc
Dials for ammeter
* See selection tables opposite
Weight (kg)
0.2
0.2
0.3
Weight (kg)
0.1
Weight (kg)
0.1
Weight (kg)
0.1
0.1
0.1
0.1
0.1
0.1
0.09
Weight (kg)
0.09
Volume (dm³)
0.4
0.4
0.4
Volume (dm³)
0.4
Volume (dm³)
0.4
Volume (dm³)
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Volume (dm³)
0.4
0966 36
0966 37
0966 38
Cat. No
0988 52
Cat. No
0962 99
Cat. No
0988 50
0988 56
0988 57
0988 58
0988 59
0988 60
*
Cat. No
0988 49
Cat. No
Pack
1
1
1
Pack
1
Pack
1
Pack
1
1
1
1
1
1
1
Pack
1
Cat. No.
098861
098862
098863
098864
098865
098866
098867
098868
098869
098870
098871
098872
098873
098874
Cat. No.
098903
098904
098905
098906
098907
098908
098909
098910
098911
098912
098913
098914
098915
098916
3 FLC
1 A CT
graduation
0 5 15
0 10 30
0 15 45
0 20 60
0 30 90
0 40 120
0 50 150
0 60 180
0 75 225
0 100 300
0 125 375
0 150 450
0 200 600
0 250 750
3 FLC
5 A CT
graduation
0 5 15
0 10 30
0 15 45
0 20 60
0 30 90
0 40 120
0 50 150
0 60 180
0 75 225
0 100 300
0 125 375
0 150 450
0 200 600
0 250 750
Cat. No.
098875
098876
098877
098878
098879
098880
098881
098882
098883
098884
098885
098886
098887
098888
Cat. No.
098917
098918
098919
098920
098921
098922
098923
098924
098925
098926
098927
098928
098929
098930
5 FLC
1 A CT
graduation
0 5 25
0 10 50
0 15 75
0 20 100
0 30 150
0 40 200
0 50 250
0 60 300
0 75 375
0 100 500
0 125 625
0 150 750
0 200 1000
0 250 1250
5 FLC
5 A CT
graduation
0 5 25
0 10 50
0 15 75
0 20 100
0 30 150
0 40 200
0 50 250
0 60 300
0 75 375
0 100 500
0 125 625
0 150 750
0 200 1000
0 250 1250
Cat. No.
098889
098890
098891
098892
098893
098894
098895
098896
098897
098898
098899
098900
098901
098902
Cat. No.
098931
098932
098933
098934
098935
098936
098937
098938
098939
098940
098941
098942
098943
098944
6 FLC
1 A CT
graduation
0 5 30
0 10 60
0 15 90
0 20 120
0 30 180
0 40 240
0 50 300
0 60 360
0 75 450
0 100 600
0 125 750
0 150 900
0 200 1200
0 250 1500
6 FLC
5 A CT
graduation
0 5 30
0 10 60
0 15 90
0 20 120
0 30 180
0 40 240
0 50 300
0 60 360
0 75 450
0 100 600
0 125 750
0 150 900
0 200 1200
0 250 15FLC
Switch0966 37
Ammeter0988 50
Control knob0988 49
Fuse carrier0962 99
20 A switches• Door fixing with rotary control knob Cat. No. 0988 49 (not inclused)• Connection via 2 x 4 mm² terminals
Window for ammeter• Supplied with weatherproof seal and frame• Fixing system for ammeter
Zone 1 & 2 - 21 & 22
EEx e II ou EEx de IIC
ATEX CEI II 2G/D ou II 2 G
0958 50
0962 99
0966 36/37/38 + 0988 49
A B0966 36 39 540966 37/38 63 78
Dimensions and diagrams (mm)
Padlockable handle for 20 A switch• Supplied with fixing base
Ferromagnetic ammeter• Class 2.5 - Deflection 90°• Adjustable red index dial• Standard square bezel 48 mm• Connection via 2 x 2.5 mm² terminals
Fuse carrier• For cylindrical industrial cartridges type gG or aM 14 x 51 mm withstriker pin• Adaptor which clips onto EN 50 022 and EN 50 035 rail• Connection via 2 x 10 mm² terminals
100 TO 400 VA TRANSORMERS FOR ATX MARINA OR 316 L STAINLESS STEEL ENCLOSURES
ADVIGANO
Explosion ProofElectrical Equipment
Zone 1 & 2 ATEX IEC II2 G EEx e II
Weight (kg)
2.7
4.9
5.4
6.9
2.7
4.9
5.4
6.9
2.7
4.9
5.4
6.9
Weight (kg)
1.85
3.70
5.08
6.93
13.9
Primary
230/400 V
230/400 V
230/400 V
230/400 V
230/400 V
230/400 V
230/400 V
230/400 V
240/415 V
240/415 V
240/415 V
240/415 V
continuous
50
100
150
250
500
Secondary
24/48 V
24/48 V
24/48 V
24/48 V
2x110 V
2x110 V
2x110 V
2x110 V
24/48 V
24/48 V
24/48 V
24/48 V
instantaneous
105
230
420
675
1600
Power
100 VA
160 VA
250 VA
400 VA
100 VA
160 VA
250 VA
400 VA
100 VA
160 VA
250 VA
400 VA
Fixing centres
20 x 50/20 x 50
20 x 65/20 x 33
20 x 65/20 x 33
31 x 71/31 x 71
31 x 85/31 x 85
Volume (dm3)
4
4
7
7
4
4
7
7
4
4
7
7
Cat. No
0966 70
0966 71
0966 72
0966 73
0966 74
0966 75
0966 76
0966 77
0966 78
0966 79
0966 80
0966 81
Cat. No
E050TC
E100TC
E150TC
E250TC
E500TC
Pack.
1
1
1
1
1
1
1
1
1
1
1
1
EEx “e” transformers Sola International Controltransformers series
• Single phase 50/60 HzEEx “e” transormers
Sola/Hevi-Duty transformers• International Control Transformers series :
• Transformers for industrial applications, frequency 50/60 Hz (thermal insulation up to 105°C)
• Conforming to standards IEC, NEMA, ANSI, NMTBA, JIC and the most demanding industrial specifications
• Encapsulation in Epoxy resin to limit temperature rise• Tension :
208/240/415 volt primary, 120/24 volt secondary, 50/60 Hz200/230/400 volt primary, 115/23 volt secondary, 50/60 Hz220/380 volt primary, 110/23 volt secondary, 50/60 Hz
exclusively for installation in EEx “d” equipment
VA power ratings for duty type
TECHNICAL DATA
Zones :1 and 2
Classification :• Ref. 0966 70 to 0966 81• According to CENELEC :- Conforming to ATEX Directive 94/9 EC and standards EN
50014-19- 0081 II2 G for gas EEX e II• According to IEC : Ex “e” II - LCIE: Ex 03.008 U- Conforming to standards IEC 60079-0/7 Ex e II
Certification :• Approved type: TSN - TSCN• CENELEC LCIE 03 ATEX 0021 U• IEC LCIE Ex 03.028 U• Declaration of conformity 5C222 for components• Conforming to standards EN 61558-2-4 and EN 61558-2-6
and corresponding IEC standards• “Safety of isolation transformers” and “Safety of
transformers: general rules”
Operating temperature :-20°C to + 40°C
• These components can be installed in zones 21 - 22 in an approved dustproof enclosure, as long as the maximum power dissipation is not exceeded
200
Recommended