An Innovative Energy Saving Primary Filtration Using Cloth ...An Innovative Energy Saving Primary...

Preview:

Citation preview

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Jia (Jack) Ma, PhD, PE, D.WREProduct Manager – Filtration

An Innovative Energy Saving Primary Filtration Using Cloth Media Technology

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Agenda

• Introduction to Aqua-Aerobic Systems

• OptiFiber® Pile Cloth Media Filtration

• Primary Filtration at Rock River Water Reclamation

District, IL

• Summary

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Aqua-Aerobic Systems, Inc.Loves Park, IL

• Founded in 1969, Privately Held Company

• 130 Employees (Office and Manufacturing)

• Applied Engineering Focus

• > 10% of Profits Back to R&D

• Manufacture Key Components

• > 24 Patented Products and Processes

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Technology Timeline

1969

Aqua‐Jet® Aerator

1975 1984 1986 1991 1993 1999 2003 2004

AquaDDM® Mixer

AquaABF® Filter

Aqua MixAir®System

AquaSBR® System

Aqua MSBR® System

Cloth Media Filtration

AquaMB Process®

System

AquaDiamond® Filter

2005

Aqua‐Aerobic® MBR System

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Technology Timeline

2006

AquaPASS® System

IntelliPro® Process

Management System

ContinuedInnovation

2008 2009 2010 2011 2012

AquaBioMax™

OptiFiber PES‐14

MicroFiber OxyMix® Pure Oxygen Mixer

Aqua 

UltraFiltration™

Flow Characterization 

Intellipro®Aqua‐Jet® TTHM Approval

2013

Research Technology Center

Aqua MegaDisk™

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Filtration ExperienceOver 3,000 Units Installed

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

OptiFiber® Pile Cloth Media Filtration

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

OptiFiber Pile Cloth Media

• Pile Construction

• Polyester Support Backing

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Maximize

• Removal of TSS

• Hydraulic throughput

Minimize

• Chemical

• Backwash

Filtration Goals

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Filtration Particle Removal Mechanisms

Straining

Sedimentation

Impaction

Interception

Adhesion

Flocculation

Surface Mechanism

Depth Filtration

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

So, what does all this mean?

Rapid Sand Filter

L/D = 500-1000

PES-14 Microfiber

L/D = 425-715

L/D Ratio

L=300-600 mm

D=d10=0.6 mm D≈0.007 mm

L=3-5 mmWhen wet

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Filtration Particle Removal Mechanisms

Surface Mechanism Depth Filtration

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

AquaDisk® Cloth Media Filter

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

How AquaDisk® Cloth Media Filter Works

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

How AquaDisk® Cloth Media Filter Works

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

How AquaDisk® Cloth Media Filter Works

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Primary FiltrationRock River Water Reclamation District

April 8 – July 13 2014

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Testing Objectives

Hydraulic and solids loading capabilities

Relative cloth performance (PA2-13 vs. Microfiber vs. Clarifier)

Energy savings

BW/SW volume and frequency (% of applied flow)

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Research & Technology Center

– Located at Rock River Water Reclamation District

– 80ft by 60 ft x 14 ft (tall)– Inputs: primary influent and

effluent, secondary effluent, RAS

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Testing Equipment

Screen (¼ inch

openings) Filtration

Grit removal

Raw Sewage

Primary

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Testing Conditions

24/7 operation

Side-by-side testing with primary clarifier

Flux rates 3.25 – 4.0 gpm/sf-day, mostly 3.25 gpm/sf-day

Filter influent TSS averaged 236 mg/L (104 – 526 mg/L)

Solids loading rates approximately 9 – 10 lb/sf-day

No chemical addition

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

OptiFiber PA2-13®

(April 8 – May 9, 2014)

OptiFiber® Pile Cloth Media Tested

OptiFiber PES-14®

(May 9 – July 13, 2014)

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results:

1Represents the average of daily removals Σ(inf-eff)/∑inf, not removal of overall averages (Σinf –Σeff)/Σinf2Results represent one grab sample per medium

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – TSS & BOD Removal:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – TSS Removal:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – TSS Trending

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – TSS Trending

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – BOD Removal:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – BOD Trending

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – BOD Trending

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – UVT Improvement:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – UVT Trending

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Results – UVT Trending

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Summary

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Performance

• Consistently high effluent for the variable influent conditions

Filters in lieu of Primary Clarification

• Better removal of TSS and BOD5

• More VSS (~25-38%) to the anaerobic digester

• More energy recovery (gas production)

• Less energy (~30-45%) use in the downstream aeration process

Primary Effluent Disinfection Systems

• Reduced Energy/Improved performance

Implications:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

Backwash

• Ranged from 12 to 13% of the applied flow

• Optimization was not an objective of this study

• Improvement can be achieved by BW set-point adjustment and filter basin re-design

Fats, Oils and Grease (FOG)

• Did not affect the operation or removal performance

Implications:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

40 ft

60 ft

Settling Basin

12 ft

20 ft

Aqua MegaDisk Filter

Implications:

Providing AdaptiveProviding Adaptive Water ManagementWater Management SolutionsSolutions

• Replacement of primary clarifier for better removals and smallerfootprint

• Carbon reduction to reduce energy in the activated sludge process

• Carbon diversion to improve gas production in anaerobic digestion

• Treatment of combined and sanitary sewer overflows (CSO & SSO) for TSS and BOD reduction

• Stormwater treatment

• Other high solids treatment process

Potential Applications:

Recommended