PROJECT GUIDE :M.RAVI
BY: B.V.S. ALEKHYA (10521A04A1) SHUBHAM KUMAR (10521A0487)ROHIT SOURABH (10521A0484) V.BHANU CHAITANYA(10521A04A4)D.V.Y.V. SUBBA RAO (11525A0403)
ARM BASED 4-BIT CODED LOCKER WITH ELECTRIC SHIELD
INTRODUCTIONBLOCK DIAGRAMSECTIONSLOCKING SECTIONCONTROLLING SECTIONNECESSITY TO USE ARMCIRCUIT DIAGRAMCOMPONENTS REQUIREDWORKINGADVANTAGES INVOLVED IN THE PROJECTIMPROVEMENTS THAT CAN BE MADE
CONTENTS
Disadvantage of conventional mechanical lockers- high cost and comparatively lower security
It is an electronic code lock based on NXP LPC2148 microcontroller
Alphanumeric password is needed to open the locker
If password is wrong a buzzer blows to alert security within reach
The burglar may be subjected to shock if he tries to touch the locker
INTRODUCTION
BLOCK DIAGRAM
LOCKING SECTION
TECHNOLOGY USED:
We used actuating technology for the locking section
We used motor with a nut and bolt and designed an actuator
This actuator will be used for auto closing and opening of locker
SECTIONS
LOCKING SECTION
CONTROLLING SECTION
LOCKER
we connected a nut and bolt to a geared motor and designed the locker unit
DPDT SWITCH
we used a dpdt toggle switch for opening and closing of the locker
ELECTRIC SHIELD
we placed the conductor around the walls of locker
this conductor is allowed free flow of electric supply and it is indicated by red color led circuit
LPC2148 is based on 32 bit ARM7TDMI(-S) developed by ARM Holdings
3-stage pipeline Keeps its instructions and data in the same memory system High speed on-chip flash memory of 512 KB Embedded ICE hardware, give on-chip breakpoint and
watchpoint support
High performance and very low power consumption
Two instruction sets: 1. Standard 32-bit ARM instruction set. 2. 16-bit THUMB instruction set. On-chip static RAM (SRAM) Enhanced Multiplier, 64-bit result
CONTROLLING SECTION
Why ARM?
LOW COST LOW POWER REQUIREMENTS LOW POWER DISSIPATION MULTIPLE FUNCTIONALITIES BETTER RAM AND ROM
CAPABILITIES RISC-BASED PROCESSOR INDUSTRIAL REQUIREMENTS
CIRCUIT DIAGRAM
Blueboard equipped with NXP LPC2148 microcontrollerQWERTY keyboardRelayElectronic lockerSpeakers
COMPONENTS REQUIRED
NGX Blue Board
KEYBOARD CONNECTIVITY WITH THE BLUEBOARD
WORKING OF THE WHOLE SYSTEM
When the user enters a password using the Keyboard attached to the Blueboard, then the logic built in the Embedded C program checks it with the pre-stored password. 1. If both the passwords match, then the LCD displays the “ Correct Password” message and after 2 seconds instructs the user to toggle up/down the Red Switch connected to the relay by displaying a message “Toggle Red Switch”. 2. If the password entered by the user is wrong, then the LCD will display the message as “Password Wrong, Try Again” by alarming with a buzzer attached to the Blueboard and gives the user 2 more chances of entering the correct password. If the user still fails to type the correct password in their 3rd attempt,then the LCD displays the message as “Security Alarm” and the microcontroller will send a Security alarm signal by generating an audio signal for 15 seconds which will be played on the speaker.
DISPLAY ON ENTERING CORRECT PASSWORD
DISPLAY ON ENTERING WRONG PASSWORD MORE THAN THRICE
ADVANTAGES INVOLVED IN THE PROJECT• Highly Secure due to the presence of multilevel security with electric shield• The development board requires just 3.3 V of power supply and hence power consumption and dissipation are very low.• Security alarm with the help of DAC is possible, thus alerting the security personnel if any unauthorized repeated access is made more than thrice.• Inability for any unauthorized user to access the locker due to the presence of all-time electric shock.• One-minute blocking of the whole system if any unauthorized access is made more than thrice.• Made on a low budget of Rs. 4200 which is quite low as compared to the similar type of system available in the market
IMPROVEMENTS THAT CAN BE MADE
• GSM-GPS INTERFACE CAN BE INCORPORATED• A BETTER USER INTERFACE CAN BE PROVIDED
THROUGH HYPER-TERMINAL USING RS-232 COMMUNICATION AT THE COST OF INCREASED BUDGET
• A PERIODIC ALARM CAN BE CONFIGURED FOR MORE ENHANCED SECURITY USING THE RTC MODULE PRESENT IN THE BLUEBOARD