View
232
Download
0
Category
Preview:
Citation preview
7/26/2019 ASTS Liabilities
1/65
Liabilities to AssetsLiabilities to Assets
Presented by:Presented by:
Eric BonnerEric Bonner
Corrpro Companies, inc.Corrpro Companies, inc.Atlanta, GeorgiaAtlanta, Georgia
EBonner@corrpro.comEBonner
@corrpro.com
(678) 848-0688(678) 848-0688
7/26/2019 ASTS Liabilities
2/65
IRON OXIDE REFINING MILLING
STEEL CORROSION IRON OXIDE
THE PROBLEMTHE PROBLEM....
7/26/2019 ASTS Liabilities
3/65
7/26/2019 ASTS Liabilities
4/65
Why Provide Corrosion Control?
Regulatory Compliance
Preserve Assets That Have Become
LIABILITIES!
Dramatically Reduce Likelihood of
Product Releases
Significantly Reduce Maintenance Costs
Environmental Preservation
7/26/2019 ASTS Liabilities
5/65
7/26/2019 ASTS Liabilities
6/65
7/26/2019 ASTS Liabilities
7/65
7/26/2019 ASTS Liabilities
8/65
7/26/2019 ASTS Liabilities
9/65
Anodic Area
-600mVCathodic Area
-550mV
SAND
CURRENT FLOW
External Corrosion of
Tank Bottom
7/26/2019 ASTS Liabilities
10/65
SANDCURRENT FLOW
Corrosion Cell Caused
by Foreign Material in
Sand Cushion
CLAY
Steel Tank Floor
7/26/2019 ASTS Liabilities
11/65
7/26/2019 ASTS Liabilities
12/65
New Bottom (Anode)
CURRENT FLOW
SAND
SAND
New Steel Coupled to Old Steel
Old Bottom (Cathode)
7/26/2019 ASTS Liabilities
13/65
DRY
SAND
MOIST SAND
WATER
Corrosion Caused by
Poor Water Drainage
7/26/2019 ASTS Liabilities
14/65
- Approximately 25% of States now- Approximately 25% of States now
require cathodic protection be installedrequire cathodic protection be installed
and maintained on new, refurbished, orand maintained on new, refurbished, or
repaired tanks in contact with soil orrepaired tanks in contact with soil orsand foundations.sand foundations.
- A number of other states are in the- A number of other states are in the
process of implementing regulationsprocess of implementing regulationsgoverning ASTgoverning ASTs.s.
State Level
7/26/2019 ASTS Liabilities
15/65
MAJOR OIL
Vast Majority of Oil Marketers Have
Employed CP for Decades
Laws Changing Dramatically
7/26/2019 ASTS Liabilities
16/65
Types of Cathodic Protection
GalvanicGalvanic: Current obtained from a metal: Current obtained from a metalwith a higher energy level. with a higher energy level.
Impressed CurrentImpressed Current : Requires external: Requires externalpower source (transformer power source (transformer
rectifier). rectifier).
7/26/2019 ASTS Liabilities
17/65
7/26/2019 ASTS Liabilities
18/65
Structure
MagnesiumAnode
Current Flow
Galvanic Cathodic Protection
7/26/2019 ASTS Liabilities
19/65
7/26/2019 ASTS Liabilities
20/65
Test
Box
Anode
Cells
Tank
Galvanic Anodes
7/26/2019 ASTS Liabilities
21/65
SAND QUALITY
The rate of corrosion is dependent on the
characteristics of the sand.
The 1stmeans of corrosion control is a
good quality sand material.
On-site testing has indicated that
provided sand is as much as ten timesmore corrosive than recommended sand.
7/26/2019 ASTS Liabilities
22/65
Sand Recommendation
Silica
pH Between 6.5 and 8.5
Moisture less than 5%
Chlorides less than 10 ppm
Resistivity greater than 30,000 ohm-cm
7/26/2019 ASTS Liabilities
23/65
Rectifier
Anode
Groundbed
( - ) ( + )
Pipeline
(Structure)
Current
Flow
Impressed Current System
7/26/2019 ASTS Liabilities
24/65
7/26/2019 ASTS Liabilities
25/65
Above Ground Storage Tank Vertical ImpressedAbove Ground Storage Tank Vertical Impressed
Current Anodes - Existing TanksCurrent Anodes - Existing Tanks
Sand
Anodes
Rectifier
NegativeConnection
+
-
Concrete
Ringwall
Tank
AnodesRectifier
-
+
Negative
Connection
Tank
7/26/2019 ASTS Liabilities
26/65
Shallow Anodes
Tank
Rectifier
(-)
(+)
Anode
7/26/2019 ASTS Liabilities
27/65
Anodes
Junction
Box
Rectifier
-+
7/26/2019 ASTS Liabilities
28/65
Deep Anode
Tank
(+)
(-)
RectifierTank
Tank Tank
7/26/2019 ASTS Liabilities
29/65
MFLMFL FloorFloorInspectionInspection
7/26/2019 ASTS Liabilities
30/65
Mechanical Integrity
API-653 Inspections Should CoincideWith the Results of a CP SystemEvaluation
Corrosion Engineers and MechanicalInspectors Must be on the Same Page
7/26/2019 ASTS Liabilities
31/65
Tank
Rim Potential Measurements
Portable Reference Cell
Soil
(+)
????
-850mV-850mV
7/26/2019 ASTS Liabilities
32/65
Rim 25' Center 55' Rim
On -1411 -698 -404 -601 -1455
Off -902 -664 -402 -578 -911
Reference Cell
Bullseye
Monitoring
Tube
Test /
Access
Station
boveground
orage Tank
de
3Typical
Potentials (mV)
7/26/2019 ASTS Liabilities
33/65
Directional Boring Under
Existing AST
7/26/2019 ASTS Liabilities
34/65
2 !PVC
Grade
Aboveground
Storage Tank
3
Typical
Test/Access
Station
Monitoring
Tube
REFERENCE CELL MONITORING TUBEREFERENCE CELL MONITORING TUBE
7/26/2019 ASTS Liabilities
35/65
Directional Bore Under Tank for Anode or
Reference Cell Placement
7/26/2019 ASTS Liabilities
36/65
ABOVEGROUND STORAGE TANK
CATHODIC PROTECTION
3!PVC 20%Exposure
Anode Material
Anode Tube
10
Typical
Test/Acces
s Station
Grade
Aboveground
Storage Tank
7/26/2019 ASTS Liabilities
37/65
Computer Guided Horizontally
Bored Anode System
Tank
Rectifier
(+)
(-)
Anode
Splice Box
Anode
Pipe
Monitoring
Pipe
Anode Pipe
7/26/2019 ASTS Liabilities
38/65
CP Applications for Re-bottomed orCP Applications for Re-bottomed or
New TanksNew Tanks
7/26/2019 ASTS Liabilities
39/65
New Floor Installation on Existing ASTNew Floor Installation on Existing AST
7/26/2019 ASTS Liabilities
40/65
Anode
Reference
Cells
Tank
Impressed Current
Junction
Box
(-)
(+)
Rectifier
7/26/2019 ASTS Liabilities
41/65
CP Installation on Rebottomed TankCP Installation on Rebottomed Tank
7/26/2019 ASTS Liabilities
42/65
Above Ground
Storage Tank Bottoms
with Secondary Containment
7/26/2019 ASTS Liabilities
43/65
New Tank Construction with LinerNew Tank Construction with Liner
7/26/2019 ASTS Liabilities
44/65
Anode & Reference Cell PlacementAnode & Reference Cell Placement
in High Resistance Sandin High Resistance Sand
7/26/2019 ASTS Liabilities
45/65
7/26/2019 ASTS Liabilities
46/65
Liner
Floor
AnodeConduit
CP Installation on Double Bottom TankCP Installation on Double Bottom Tank
7/26/2019 ASTS Liabilities
47/65
Installation of CP System onInstallation of CP System on
Lifted ASTLifted AST
7/26/2019 ASTS Liabilities
48/65
Explosion Proof Unit
7/26/2019 ASTS Liabilities
49/65
Reference Cell Placement Under Tank Bottom
7/26/2019 ASTS Liabilities
50/65
Inspection of CP SystemInspection of CP System
7/26/2019 ASTS Liabilities
51/65
-Record Volts/Amps
-Compare values to target settings
7/26/2019 ASTS Liabilities
52/65
7/26/2019 ASTS Liabilities
53/65
Cathodic Protection Monitoring
Read rectifiers every 60 days.
Conduct annual inspection (obtainpotentials) by NACE certified
individuals.
7/26/2019 ASTS Liabilities
54/65
7/26/2019 ASTS Liabilities
55/65
7/26/2019 ASTS Liabilities
56/65
Annual Cathodic Protection Survey
7/26/2019 ASTS Liabilities
57/65
Internal Corrosion
7/26/2019 ASTS Liabilities
58/65
Anode Cathode
Water / Sediment
Fuel Product
Internal Corrosion
7/26/2019 ASTS Liabilities
59/65
CoatingAnode
Bolt
Tank Bottom
7/26/2019 ASTS Liabilities
60/65
Hot Asphalt Tank Bottoms (require special CP
design considerations due to heat)
7/26/2019 ASTS Liabilities
61/65
Recommended Practices
API-651 - Cathodic Protection of Aboveground Petroleum
Storage Tanks:
NACE RP0193-2001 - External Cathodic Protection of On-
Grade Carbon Steel Tank Bottoms:
7/26/2019 ASTS Liabilities
62/65
Recommended Practices
API-651 - Cathodic Protection of Aboveground Petroleum
Storage Tanks:
Galvanic anodes method is not practical for
protection of large bare structures.
NACE RP0193-2001 - External Cathodic Protection of On-
Grade Carbon Steel Storage Tank Bottoms:
Galvanic protection systems can be applied to
tank bottoms where the metallic surface areaexposed to the electrolyte can be minimized
through the application of a dielectric coating or the
area is small due to the tank size or configuration.
7/26/2019 ASTS Liabilities
63/65
SummarySummary
- Be aware of all regulations that may
pertain to your tanks and piping. When in
doubt talk to the governing agencies.
- Engage NACE qualified & experienced
personnel to engineer/maintain your
cathodic protection system.
- Refer to NACE/API Standards for guidance.
7/26/2019 ASTS Liabilities
64/65
QuestionsQuestions
7/26/2019 ASTS Liabilities
65/65
Thank YouThank You
Eric BonnerEric Bonner
Corrpro Companies, Inc.Corrpro Companies, Inc.
Atlanta Regional OfficeAtlanta Regional Office
Office (770) 761-5400Office (770) 761-5400Mobile (678) 848-0688Mobile (678) 848-0688
E-MailE-MailEBonner@corrpro.comEBonner@corrpro.com
Recommended