Basement extensions are a good way to create additional living space. Unused areas in the basement can be easily converted into appartments or hobby rooms using sewage lifting units. The Gerios® not only pumps wastewater from the toilet and urinal, but also wastewater from the bidet, washbasin and shower thanks to its versatile connection options. Furthermore, the installation of an additional toilet in rooms with a long distance to the main sewage pipe or sewer can be realized with the Gerios®. For installations below the backflow level, the system also serves to protect against backflow from the sewer and always remains ready for action.
Flexible application
The Gerios® made by Zehnder Pumpen in Germany covers both installation option within one device. Both the classic direct connec-tion to a free-standing toilet and the modern, invisible installation within an in-wall element using a wall-mounted toilet can be real-ised thanks to its compact dimensions. All the necessary parts for using the various connections are included in the scope of delivery.
In-wall installation or direct connection
3
The Gerios® in detail
Even though wet wipes and toiletries must not be disposed in a toi-let, experience has shown that this regulation is often disregarded on purpose or unintentionally. In order to ensure operational safety even in this exceptional situation, the Gerios® has a unique and extremely powerful cutting system.
Precise cuttingThe special construction of the cutting blade with 3 cutting edges and the cutting plate in combination with a cutting gap of less than 0,05 mm ensures reliable cutting of more solid materials and fibres. The design guarantees maximum comminution of solid materials with 1,200 cutting operations per second.
High-quality materialsThe high-performance cutting system is made of corrosion-resistant special steel 1.4112 with extreme hardness (67 HRC). The used ma-terials provide very high wear-resistance and guarantee correspond-ingly optimal cutting performance in the long-term.
Scan this QR-code to see the cutting system in action:
13
1
2
3
4
5
6
7
8
9
1 Pressure outlet DN 40 with integrated non-return flap 2 Air vent with active carbon filter and ball valve (alternatively ventilation via pipe) 3 Pressure hose with tank flushing system 4 Inlet DN 40 with non-return flap valve 5 Coupling system 6 Pump - wet installation
7 Pitot tube8 Control box IP 689 Inlet options DN 40 10 Control box IP 6811 Inlet DN 40 with non-return flap valve12 High-performance cutting system13 Waste water guidance system
10
11
12
High-performance cutting system
4
Technical data
Hydraulic performance
Max. head 11,0 m
Max. flow rate 7,5 m³/h
Motor
Power supply 230 V
Nominal current 2,5 A
Speed 2.950 min-1
Capacitor 15 µF
Frequency 50 Hz
Power output P1 560 W
Power output P2 350 W
Protection class IP 68
Isolation class F
Switch-on mode direct
Motor protection thermal winding protection
Motor cooling jacket cooling
Cable
Cable length 1,5 m
Cable type H05
Cable cross section 3G1,5
Power plug Safety plug
Field of application
max. medium temperature 40° C
max. medium temperature (short term) 90° C
Materials
Material impeller Polypropylene PPH GF30
Motor seal Mechanical seal
Pump seal Mechanical seal
Container material Acrylonitrile butadiene styrene ABS
Material motor housing stainless steel 1.4404
Material pump housing Polypropylene PPH GF30
Material cutting unit stainless steel 1.4112
General Information
Net weight 9,5 kg
Tank volume 11,5 l
I/O switching pneumatic pump control
Outlet connection variable 1 1/4“MPT, 1 1/4“ FPT, DN28, DN32
Inlet connection 2 x DN 85, 4 x DN 40
5
Pump performance
8m
7m
6m
5m
4m
3m
2m
1m
max. 82 m (16 m)
max. 126 m (78 m)
max. 170 m (140 m)
max. 214 m (202 m)
max. 258 m (264 m)
max. 302 m (326 m)
max. 346 m (388 m)
max. 390 m (450 m)
*valid for pipeline 1 ¼“ (1 ½“)
max. 38 m Attention: min. 1% line gradient
6
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
50 50
180
335
180
289
361
70 80
75 55
410
505
161
178
192inlet DN40
blind cover / inlet toilet
inlet toilet
pressure pipe rotatableMT & FT 1¼" pipe connection: outer diameter 28 & 32126
optional air vent / inlet DN40
Dimensions and connections
Installation examples
8 6 5 4 3 27
8 67 345 2 1
1
B
D
C
A
F
E
A
E
B
C
D
F
Zulauf DN40Zulauf DN40
Anschluss WC
Druckleitung schwenkbarAG & IG 1¼ ZollRohrleitungsanschluss: Außendurchmesser 28 & 32
Entlüftung
50 50
336
289
410
180
8 6 5 4 3 27
8 67 345 2 1
1
B
D
C
A
F
E
A
E
B
C
D
F
50
410inlet DN40
inlet DN40
pressure pipe rotatableMT & FT 1¼" pipe connection: outer diameter 28 & 32
289
50
inlet toilet
Ventilation
336
289
410Inlet DN 40
50
Pivotable pressure lineMPT & FPT 1¼“ Pipe connection: External Ø 28 & 32
Inlet DN 40
50
WC connection Ventilation
41050 50
Inlet DN 40Inlet DN 40
WC connection
Pivotable pres-sure lineMPT & FPT 1¼“ Pipe connecti-on: External Ø 28 & 32
7
Maintenance made simple No tools are required to remove the motor unit. Simply slide the tank cover aside and take out the pump and motor unit by pulling it upwards. The pump is connected to the pressure hose via an automatic coupling system inside of Gerios® and is therefore easy to detach.
Easy installation & maintenance
Extensive range of accessoriesAll parts required for the installation are included in the scope of delivery:• buoyancy protection• inlet nozzle DN 40• outlet connection 1 1/4” MPT/FPT, Ø32
and Ø40 connection• small parts and fastening materials
The available optional accessories are small horn, signal light and also a humidity sensor.