Cobra-StretchA M P L I F I E D P U L S E D D Y E L A S E R S
The Cobra-Stretch from Spectra-Physics is an amplified pulsed dye laser system, Germanengineered by our partner firm Sirah GmbH for precision, stability and reliability. Featuresinclude integrated oscillator / pre-amplifier, quick change dye cuvettes, optional amplifier orFrequency Conversion Unit (FCU). The Cobra-Stretch systems optional amplifiers can beupgraded to the enhanced beam, high pump energy EBP cells. External wavelengthconversion units extend the tuning range from the deep UV to the near IR.
The Cobra-Stretch meets output energy needs up to 250 mJ. Based on a two stage design,the Cobra-Stretch can accommodate an extra amplifier stage to obtain higher energies or afrequency conversion unit to extend the range of attainable wavelengths, either of which isconveniently housed inside the main laser cabinet.
The Cobra-Stretch dye laser incorporates a grazing incidence resonator designed to utilizethe grating’s dispersion twice per oscillator round-trip, ensuring narrow linewidths with lowASE. An optional second grating can be added to the resonator for ultra narrow linewidthsbelow 0.03 cm-1 at 570 nm. The Cobra-Stretch resonator allows narrow line tuning over abroad tuning range without the need for an intra-cavity etalon, thus simplifying themeasurement process without sacrificing performance.
The Cobra-Stretch laser’s quartz dye cuvettes are held in place by state-of-the-art cellmounts manufactured for stability and precision from high performance alloys and graphite-reinforced polymers. Designed for extreme ease of use, the mounted cuvettes and the entiredye circulator unit can be removed in seconds without tools and without interrupting thedye flow loop. This design is ideal for applications that require more than one type of dye.The quick change from one dye defined wavelength range to another saves time andeliminates the need for messy dye changes.
Dye flow rates for the standard circulator and cell assemblies are high enough to work up to50 Hz with higher power pumps available for higher repetition rates. For additionalversatility, the Cobra-Stretch system’s circulators operate with polar and non-polar solvents,as well as solvents of varying viscosities.
Reliability is inherent in the Cobra-Stretch laser design. All oscillator components aremounted on a solid block of low thermal expansion stainless steel, mechanically andthermally isolated from the outer laser housing. By removing virtually all mechanical andthermal stress from the oscillator block and by using opto-mechanics optimized for easy andreproducible operation, the oscillator stage requires very limited user adjustment. Thismechanical stability results in a wavelength resettability for the oscillators of 11 µm
• Spectral linewidths 180 mJ with Quanta-Ray® Nd:YAG at650 mJ per pulse
• High quality beam profile with capillary cell option
A P P L I C A T I O N S
• Laser induced fluorescence
• Lidar and remote sensing
• Combustion and atmospheric studies
• Laser spectroscopy
• Cavity ringdown spectroscopy
• CARS
• Photolysis
Cobra-Stretch Optical Layout
Mirror(Delay)
Mirror(Delay)
Beam Expansion
Dye Output
TuningMirror
OutputCoupler
BeamSplitterPump
Beam
BeamReversion
CylindricalLenses
Beamsplitter(Pre-amp)
Grating
Telescope
Prism
CylindricalLenses
40 mm Dye Cell20 mm Dye Cell
Cobra-Stretch Dimensions
Side View
7.8
..9.
1(1
97..
230)
154
3718
(457)
13.2(334)
6.3(160)
8.2
..9.
5(2
07..
240)
polarization
19.5(494)
12.3
..13
.6(3
12..
345)
Pump Laser Input End
6.1(154)
1.5(37)
Dye Laser Output End
Dimensions in inches (mm)
37.3(947)
35(877)
1.4(35)
Cobra-Stretch
Cobra-Stretch Specifications
1. At 625 nm (peak DCM) pumped at 532 nm2. At 570 nm (peak Rhodamine 6G) pumped at 532 nm3. Exact linewidth depends weakly on wavelength; value given for 450 nm4. 1800 lines per mm Woods Anomally occurs at 560–571 nm and 2400 lines per mm Woods Anomally occurs at 423–434 nm
Prism Model Linewidth Specifications
Model Groove Density Grating Length Tuning Range Linewidth EfficiencyCobra-Stretch-P – – 370–900 nm 150 pm 5 cm-1(1) 20%1
Grating Models Linewidth Specifications
Model Groove Density Grating Length Tuning Range Linewidth
EfficiencyWith
Amplifier
EfficiencyWithout
AmplifierCobra-Stretch-G 1800 lines/mm4 60 mm 400–900 nm 3.6 pm 0.10 cm-1(1) 10%1 28%1
2400 lines/mm4 60 mm 350–740 nm 2.7 pm 0.08 cm-1(2) 9%2 27%2
3000 lines/mm 60 mm 350–610 nm 2.0 pm 0.06 cm-1(2) 9%2 26%2
Cobra-Stretch-LG 1800 lines/mm4 90 mm 400–900 nm 2.4 pm 0.06 cm-1(1) 10%1 28%1
2400 lines/mm4 90 mm 350–740 nm 1.8 pm 0.06 cm-1(2) 9%2 27%2
3000 lines/mm 90 mm 350–610 nm 1.4 pm 0.05 cm-1(2) 9%2 26%2
Cobra-Stretch-D 1800 lines/mm4 2 x 90 mm 410–900 nm 1.7 pm3 0.05 cm-1(1) 8%1 25%1
2400 lines/mm4 2 x 90 mm 350–710 nm 1.2 pm3 0.04 cm-1(2) 8%2 25%2
3000 lines/mm 2 x 90 mm 350–580 nm 1.0 pm3 0.03 cm-1(2) 8%2 25%2
Wavelength and Beam CharacteristicsAbsolute Wavelength Accuracy
Family of Brands – Corion® • New Focus™ • Oriel® Instruments • Richardson Gratings™ • Spectra-Physics®
PHONE EMAILBelgium +32-(0)0800-11 257 belgium@newport.comChina +86-10-6267-0065 china@newport.comFrance +33-(0)1-60-91-68-68 france@newport.comJapan +81-3-3794-5511 spectra-physics@splasers.co.jpTaiwan +886 -(0)2-2508-4977 sales@newport.com.tw
PHONE EMAILIrvine, CA, USA +1-800-222-6440 sales@newport.comNetherlands +31-(0)30 6592111 netherlands@newport.comUnited Kingdom +44-1235-432-710 uk@newport.comGermany / Austria / Switzerland
+49-(0)6151-708-0 germany@newport.com
3635 Peterson Way, Santa Clara, CA 95054, USA
PHONE: 1-800-775-5273 1-408-980-4300 FAX: 1-408-980-6923 EMAIL: sales@spectra-physics.com
www.newport.com/spectra-physics
Newport Corporation, Irvine, California and Franklin, Massachusetts; Evry andBeaune-La-Rolande, France and Wuxi, China have all been certified compliant withISO 9001 by the British Standards Institution. Santa Clara, California is DNV certified. Complete listings for all global office locations are available online at www.newport.com/contact
Newport Corporation, Global Headquarters PHONE: 1-800-222-6440 1-949-863-31441791 Deere Avenue, Irvine, CA 92606, USA EMAIL: sales@newport.com
DS-051003
© 2010 Newport Corporation. All rights reserved. Quanta-Ray, Spectra-Physics, the Spectra-Physics logo and the Newport logo are registered trademarks of Newport Corporation.
Fluore
scein
27
Pyrro
m.58
0
Rhod
amine
6G
Pyrro
m.59
7
Sulfo
rhoda
mine
Rhod
amine
B
Mix.
DCM
(Etha
nol)
Rhod
amine
101
DCM
(DMS
O)
Pyrid
ine1
Pyrid
ine2
Styryl
8 (Eth
anol)
Styryl
8 (DM
SO)
Styryl
11
Styryl
9 (Eth
anol)
Styryl
9 (DM
SO)
LDS 8
67
5
10
15
20
25
30
600550 650 750 850700 800 900
Wavelength (nm)
Effic
ienc
y(%
)
Wavelength (nm)
Effic
ienc
y(%
)
380 400 420 440 460 480 500 520 540 560
5
10
15
20 Exali
te37
6
Exali
te38
4
Exali
te38
9
M ix .
389 /
398
Exali
te40
4
Exali
te41
1
Exali
te41
7
Stilb
ene 3
Exali
te42
8
C oum
ar in 1
20
C oum
ar in 2
C oum
ar in 4
7
C oum
ar in 1
02
C oum
ar in 3
07
C oum
ar in 1
53
532 nm-pumped Dye Tuning Curves
355 nm-pumped Dye Tuning Curves
Cobra-Stretch
Recommended