DIAMANTINSTALLATION MANUAL

www.gerardroofs.eu

UNDERLAY AND BATTENS

TECHNICAL

Length of cover: 1270 mm Width of cover: 398 mm Tiles/m2: 1.98Weight/m2: 6.28 kg Minimum Pitch: 14°

STORAGE AND HANDLING:If storage outside, a waterproof cover must be placed over the tiles to keep them dry and prevent damage to the substrate.

NON-STANDARD ELEMENTS: Materials that could cause corrosion (e.g. copper, lead, stainless steel) should not be used above the level of the roof.

ROOF TRAFFIC:Weight should be placed directly over the batten in pans of tile when walking on the roof.

WET SURFACE:Walking and working on a wet roof should not be attempted.

BATTENS:Recommended counter batten dimension is 50 x 80 mm. Tile batten size is 40 x 50 mm (distance between rafters less then 900 mm)

BATTEN SPACING:Batten spacing for Diamant is 398 mm.

LOCAL STANDARDS:It is strongly recommended that local building standards and regulations are always followed and fully complied with.

Overall installation manual:For more information see the GERARD INSTALLATION MANUAL

398 mm

RIDGE BATTEN

EAVESHIP BATTEN

GABLE

VALLEY BATTEN SPACING

398 mm

1.

2.

3.4.

360 mm 60 mm

180 mm

Bottom tile

Top tile

2 .

1. 1.

6.

7.

8.

9.

10.

4.5.

2 .

3.

Centerline of pan

Edge of tile BEdge of tile A

Bottom tile

Tile A

Tile B

TILE LAYING

INTERLOCKING OF THE TILES

NAIL POSITIONING

EAVES FLASHING

RIDGE INSTALLATION

HIP INSTALLATION

BOX BARGE INSTALLATION

VALLEY INSTALLATION

WALL FLASHING

Recommended