Peter Norlin 11 Nov 2014

DIGITAL X-RAY INSPECTION OF

WELDS

www.acreo.se

BACKGROUND • Digital technology has taken over visible light photography • Digital X-ray imaging is well in progress in medical and dental fields • The digital transition has been slower for non-destructive testing (NDT) of welds, at least for critical applications

- Requirements from older industry standards - Possibly conservatism in the field

This project’s objective Find out if current technology and standard development allows a digital transition to be made at OHB Sweden’s satellite production line (welding of tubes for propulsion systems). Project time 2012 - 2013

www.acreo.se

Three X-ray images / weld ⇒ several hundred images for a propulsion system • No chemical development, which is

- Time consuming - Can be unreliable

• Examination – post-processing • Digital archiving and storage

POTENTIAL BENEFITS

www.acreo.se

OVERVIEW

1. Introduction to digital X-ray detector

arrays 2.Standards 3.Survey of commercial systems 4.Detector tests 5.Summary and conclusions

www.acreo.se

1. INTRODUCTION TO DIGITAL X-RAY DETECTOR ARRAYS

www.acreo.se

DIGITAL DETECTOR ARRAYS: 1) INDIRECT DETECTION

CCD x-ray detector chip, 4.9 cm x 8.6 cm, 7K x 4K matrix, Siemens OPDIMA

CCD or CMOS arrays: Light e-

Scintillator: X-ray light +

www.acreo.se

Columnar structure of a CsI scintillator. Light generated in the material is guided through the needle-like structures (~ 5 um diameter) onto the photodiodes of the detector, thus reducing detrimental scattering effects.

CsI doped with Thallium

Examples of scintillator materials used in indirect x-ray detectors

Scintillator crystal

Emission wavelength

nm CsI:Tl 540 NaI:Tl 415 Gd2O2S:Tb aka Gadox or GOS

544

SCINTILLATORS

Cherepy et al., IEEE Trans Nucl Sci, 2009

www.acreo.se

LARGE AREA DETECTORS

TFT-arrays a-Si on glass substrates

Flat panel detector, 43 cm x 43 cm, 143 um pixel size (from www.trixell.com).

Scintillator: X-ray light +

No X-ray optics ⇒ need detector of same dimensions as the object under study (typ. human body parts)

www.acreo.se

TFT FLAT PANEL DETECTOR ARRAYS

Indirect detector with scintillator layer on top Top view of the thin film

layer pixel structure.

www.acreo.se

2) DIRECT DETECTORS

amorphous Se - ZSe = 34 (ZSi =14) - Conversion: X-ray e-

- Large area depositon

Anrad GR17 a-Se based flat panel detector (43 cm x 43 cm)

TFT-arrays a-Si on glass substrates

+

www.acreo.se

PHOTON COUNTING DETECTORS Conventional detectors are charge (energy) integrating

The total X-ray energy absorbed by each pixel is registred

Photon (quantum) counting detectors

Each absorbed photon produces a charge pulse corresponding to that photon’s energy. Each pulse above a discrimination level produces a detector count.

From theoretical considerations: potential for improved noise/contrast (DQE)

Signal independent of electronic noise, if discrimination level fairly above the noise floor

With several discriminator levels, energy resolution, a.k.a. color imaging is possible

Increased ROIC complexity:

Amplifyers, discriminators, counters in each pixel area.

Count rate may be very high very fast electronics

Advances in microelectronics has made pixellated photon counting possible

Hybridization of sensor chip and ROIC through flip-chip technnology

Again, large area detector is problematic ... (from Czech Technical University in Prague)

www.acreo.se

Typical pixel dimensions General medical X-ray: ~200 um – 100 um range Mammography and dental: ~100 um – 50 um – 20 um range

SPATIAL DIGITIZING - PIXELS

www.acreo.se

SIGNAL DIGITIZING - GREY LEVELS

Digital detectors 12 -16 bit A/D conversion 212 - 216 = 4 000 - 65 000 grey levels Human eye Can distinguish ~200 different grey levels Film Grey levels are fixed once and for all at the development process. in practice 200 fixed levels. Digital detectors Display 28 = 256 grey levels adapted to the range of the human eye. However the conversion from 65 000 to 256 grey levels can be tailored by adjusting parameters such as brightness, contrast and gamma.

www.acreo.se

MAGNIFICATION TECHNIQUE

Issues: • Microfocus source needed higher cost (?) • Larger detector area needed • Room for larger object-to-detector distance needed

Increased object-to-detector distance Magnified image

Standard source unsharp image

Microfocus or nanofocus source sharp image

Principle

Result: The requirement for <40 um or <50 um pixel size can potentially be relaxed

www.acreo.se

2. STANDARDS

www.acreo.se

DIGITIZING OF STANDARDS 1997 SS-EN

1435 Non-destructive testing of welds - Radiographic testing of welded joints (Film)

2005 EN14784-2 Non-destructive testing - Industrial computed radiography with storage phosphor imaging plates – Part 2: General principles for testing of metallic materials using X-rays and gamma rays (CR)

2010 ASTM Set of standards for DDA 2010 EN

ISO/FDIS 17636-2

Non-destuctive testing of welds – Radiographic testing – Part 2: X- and gamma-ray techniques with digital detectors (CR and DDA)

Feb 2013

SS-EN ISO 17636-2

Non-destuctive testing of welds – Radiographic testing – Part 2: X- and gamma-ray techniques with digital detectors (CR and DDA), 51 pp

Feb 2013

SS-EN ISO 17636-1

Non-destuctive testing of welds – Radiographic testing – Part 1: X- and gamma-ray techniques with film (Film)

www.acreo.se

REQUIREMENTS IN EN ISO 17636-2 MINIMUM IMAGE QUALITY VALUES CONTRAST SENSITIVITY AND SPATIAL RESOLUTION

= 50 um = 63 um

www.acreo.se

IMAGE QUALITY INDICATORS (IQI)

Single wire IQI for verification of contrast sensitivity

Double wire IQI for verification of spatial resolution

W13 W19 200 um 50 um

D1 D13 800 um 50 um

www.acreo.se

3. SURVEY OF COMMERCIAL SYSTEMS

www.acreo.se

DEDICATED SYSTEMS FOR TESTING OF PIPES AND WELDS

Typical example

Satellite propulsion system application 3.2 – 0.9 mm OD 0.1 – 0.9 mm wall thickness

www.acreo.se

MEDICAL SYSTEMS Mammography • Probably the most demanding of medical imaging tasks in terms of spatial resolution and contrast resolution • Pixel size: ~25-80 um • Typ area: 18 x 24 cm2 – 24 x 30 cm2

• Energy: ~17-30 kV, (trade-off contrast/dose) • Size and weight appear to be large for inspection of fully integrated satelite systems

Dental imaging • Pixel size 20-50 um • Typ area: ~40 mm x 30 mm • Energy: ~50-100 keV, Typical ~65 keV ?

www.acreo.se

SUMMARY OF SURVEY 1st survey 15 suppliers (Mammo, dental, NDT, general) 2nd survey 22 dental X-ray suppliers, 11 with Swedish representation Visit to SweDental For the next phase - experimental evaluation – Four detectors were selected

www.acreo.se

4. DETECTOR TESTS

www.acreo.se

DETECTORS SELECTED FOR TEST

XCounter PDT25

Rad-icon Imaging (Dalsa) Radeye

Instrumentarium Snapshot

Hamamatsu S10811-11

Application Dental, mammo, general

NDT Dental Dental (NDT, general)

Detector type CdTe/Cd(Zn)Te, direct hybrid, photon counting

Gd2O2S / CMOS CMOS, scintillator not specified

CCD, scintillator not specified

Pixel pitch, µm 100 48 / 22.5 19 20

Energy spec, kV 10-160 /10-90 60-70 typ

A/D resolution, bit 32 16 16 12

Detector window, mm2

25 x 25 25 x 49 30 x 20 34 x 24

Price kSEK 65 (incl s/w) 52/56 (+19) 55 (incl s/w) 29

www.acreo.se

PIPE SAMPLES

OD, mm Wall thickness, mm Stainless steel 6.3 (1/4”) 0.9 Titanium 3.2 – 9.5 (1/8”-3/8”) 0.1-0.7

www.acreo.se

EXAMPLES OF TEST RESULTS

www.acreo.se

SUMMARY OF TEST RESULTS • All detectors passed the test regarding image quality as specified in ISO 17636 • Although: XCounter uses magnification; Contrast sensitivity was never evaluated with Instrumentarium • All detectors could identify pore defects in pipe samples

In other words: Digital X-ray detector technology can replace film for pipe weld inspection in space applications. • Hamamatsu’s detector was selected for extended verification by OHB

Good support from Hamamatsu representatives Hamamatsu not primarily a dental company Also supplier of X-ray sources Price

www.acreo.se

IMPLEMENTATION AT OHB SWEDEN IN KISTA X-ray source, 40-130 kV (Hamamatsu)

Welded pipe sample

Digital detector (Hamamatsu) inside metal fixture

www.acreo.se

IMPLEMENTATION AT OHB SWEDEN IN KISTA

Computer display used for digital X-ray image inspection

www.acreo.se

Industrial value Digital system outperforms the old film-based system in several aspects: • Faster cycle times • Lower dose rates • Digital storage • File sharing • Image processing • Less expensive • Equal or better image quality

www.acreo.se

5. SUMMARY AND CONCLUSIONS • An applicable ISO standard for radiographic non-destructive testing of welds with X-ray techniques and digital detectors was published in 2013.

• After a market survey, testing of four different digital detectors was carried out with positive results. Digital dental detectors were found to have close to ideal properties for the application.

• OHB Sweden’s primary customer, European Space Agency (ESA), approved the use of the digital ISO standard and the replacement of film with digital detectors in the weld inspection process.

• In connection with the setup of a new production facility in Kista, OHB decided to make the switch to a completely digital X-ray inspection system using a detector from Hamamatsu.

The project’s objective:

Find out if current technology and standard development allows a digital transition to be made at OHB Sweden’s satellite production line.

www.acreo.se