Voltage
Measurement range
Available fluid
Repeatability accuracy
Temp. accuracy
Operating Temp. range
Output
Residual voltage
Air pressure setting
Leakage current
StorageTemp. range
DC24V±10% DC12~24V±10%
air、non-corrosive gas、non-flammable gas
±0.7% F.S.
±2.5%F.S.
0~60℃
5~40mA
5.5V Max.
An intelligent learning button
1.0mA Max.
-20~75℃
Model DPC DPCN DPCP
DPC囗10:-100kPa~1000kPa ; DPC囗01:-100kPa~100kPa
30V/100mA Max.
0.7V Max.
Port size of connector
Special function
ø4mm,ø6mm,ø1/4"
Precautions
Specifications
1.Do NOT drop, beat or apply excessive impact on DPC. Otherwise, it may cause serious damage.2.The tensile strength of the cable is 30N. Exerting a greater tension force on it may cause serious damage.3.Do NOT use it with corrosive, flammable gas or liquid.4.Do NOT wire the cable of DPC with other power cables or high-voltage cables.5.If DPC is applied with a load, such as relay or magnetic valve, that would induce emf, an additional voltage absorption component like reverse bias diode should be applied.
Hysteresis <2%F.S.
DPC SeriesDigital Pressure Check
Circuit example
Brown
Blue
Black
Load
PowerNPN
Brown
Blue
Black
Load
PowerPNP
Brown
Blue
Load
Power2-Wire
Installation notes1.The pneumatic pipe should be insert into a connector firmly.2.Ensure no air leakage by ventilating desired air pressure.3.Follow the instruction below for pressure setting.
Dimension
36.1
30.5
29.5
9.5
Set button
Pneumatic pipe
Enclosureclassification IP40
Circuit protection Reverse polarity protection、surge protection
1: If the power supply for 2-wire type DPC is less than DC20V, the leakeage current would be greater than 1mA. Therefore, PLC may react incorrectly.2: If a relay is used as a switch for power supply, an additional capacitance should be connected between V+ and ground so as to suppress inrush current. (The capacitance is recommended to be greater than 100μF under 50 Volt.)
1.air pressure memorization2.N.O./N.C. mode switch (default: N.O. mode)
Ordering code
DPC 囗 囗 囗 囗
01: -100kPa~100 kPa 10: -100kPa~1000kPa
Output type
Blank:2-wire
N:NPN P:PNP
D4: ø4mmD6: ø6mm 08: ø1/4"
Measurement range Port size of connectorLength of wire
020: length of wire is 2m030: length of wire is 3m050: length of wire is 5m
LED explanation Instruction
Continuous light
Twinkle(10 times/sec)
Twinkle(1 times/sec)
Twinkle(3 times/sec)
LED state DPC state
LED state DPC state
LED state DPC state
Red LED(sustain 1 second):N.O. mode Green LED(sustain 1 second):N.C. mode
Red LED:(N.O mode)Measured pressure>setting pressureGreen LED:(N.C mode)Measured pressure<setting pressure
Red LED:(N.O mode)Measured pressure<setting pressureGreen LED:(N.C mode)Measured pressure>setting pressure
Simple mode
LED state DPC state
Red LED(sustain 1 second):N.O. mode Green LED(sustain 1 second)N.C. mode
Mid Value
Red LED:N.O mode Green LED:(N.C mode)
Ready for pressing
Red LED:(N.O mode)Measured pressure>setting pressureGreen LED:(N.C mode)Measured pressure<setting pressure
Red LED:(N.O mode)Measured pressure<setting pressureGreen LED:(N.C mode)Measured pressure>setting pressure
Pressure setting complete
Pressure setting complete
Pressure out of limit warning
Initial state
Red and Green LED twinkling alternately: pressure setting out of limitation of specification
Red and Green LED twinkling alternately: DPC is ready for setup.
press the button < 2 seconds
pressure the button for 2~5 seconds
setting completesetting value=
pressure at present
Green LED(sustain 1 second)
record pressure A=pressure at present PI
Green LED
press the button once
setting value=(pressure A+pressure B)/2
press the button >10 seconds.
N.O. mode
Red LED
Red LED
N.C. mode
Green LED
press the button for 6~10 seconds
N.C. mode
Red LED(sustain 1 second)
N.O. mode
N.C. modeRed LED
N.O. mode
Note: pressure of out limit warningIf the value of pressure seeting is beyond the scope of the limitation of specification, the red and green LED would twinkle alternately.Please rest the value appropriately.
Simple mode setting Mid value mode
Green LED
pressure at present
Waiting for recording pressure B
pressure at present PI
pressure at present PⅡ
record pressure B=pressure at present PⅡ
N.O./N.C. mode switch
measured pressure>setting pressure
1.Lock:It will be locked automatically as long as it is on standby for more than 120 seconds.2.Unlock:press the button for 2 seconds.
Lock
Unlock
press the button < 2 seconds
◆Quick examination for "lock state"
whether the red and green LED shine at the same time
No
Yes
Lock/Unlock mode
Reset
pressure settingvalue
N.O./N.C. mode
Lock/Unlock
default
0kPa
N.O.
Unlock
measured pressure<setting pressure
Green LED(sustain 1 second)
N.C. mode
Red LED(sustain 1 second)
N.O. mode
Green LED(sustain 1 second)
N.C. mode
Red LED(sustain 1 second)
N.O. mode
measured pressure<setting pressure
measured pressure>setting pressure
Output signal explaination
red LEDN.O.
kPa
80
40
0
-40
t
continuous light (output ON)
twinkle slowly (output OFF)
pressure setting value
Simple mode
kPa
80
40
0
-40
t
Mid value mode- It has an application for investigating whether the target is been sucked or not.
-Investigating the pressure with and without target being sucked respectively. It will calculate and set the mid value automatically.
press the button for 2~5 seconds
press the button
target no target
Mid value
green LEDN.C.
continuous light (output ON)
twinkle slowly (output OFF)
continuous light (output ON)
twinkle slowly (output OFF)
continuous light (output ON)
twinkle slowly (output OFF)
red LEDN.O.
green LEDN.C.
pressure setting value
Recommended