View
4
Download
0
Category
Preview:
Citation preview
AXIAL FLOW FANS PERFORMANCE DATA © FANTECH 2016
C
P Fd
10˚ 20˚15˚
10˚ 20˚15˚
0.3 AkW 0.2
25˚
0.3 AkW 0.2
Blade angleBlade angle0
0.2 0.6 0.80 0.4 1.0 1.2 1.4 1.6
200
100
300
500
400
031248 rev/sec
5/150
10/150
p SF-
Fan
stat
ic p
ress
ure,
Pa
qV-Volume flow, m3/s
61 61 63
61
64 64 62
60 62
68 68
0.4 AkW0.3 0.4 AkW0.3
Blade angle˚Blade angle
Absorbed kW
dB(A)@3m
0.2 0.60 0.4 0.8
10˚ 35̊25˚20˚15˚
40˚10˚ 25˚20˚15˚ 35˚35˚30˚
0
40
20
60
140
80
P Fd
031424 rev/sec
100
120
10/150
5/150
0.08 0.120.12
p SF-
Fan
stat
ic p
ress
ure,
Pa
qV-Volume flow, m3/s
49 49 48 48 48 47
48
45 45 45 45 43
47 49 48 46 46
51 51 48 48 49 49
49
0.040.04 0.08 0.16 AkW0.16 AkW
0.02 0 .04 0.06 AkW0.02 0 .04 0.06 AkW
40̊30˚ 40̊30˚Blade angle
Blade angle
Blade angle
Blade angle
Absorbed kW
dB(A)@3m
Size 315V
BS848:Part 1, 1980
Part 2 1985
Type D Installation
C-12
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
AXIAL FLOW FANS PERFORMANCE DATA
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 12
AXIAL FLOW FANS PERFORMANCE DATA
© FANTECH 2016 C-13AXIAL FLOW FANS PERFORMANCE DATA
C
Size 400V
BS848:Part 1, 1980
Part 2 1985
Type D Installation
P Fd
40˚10˚ 15˚
89
10̊ 30̊25̊20̊15̊
400
200
600
800
00.40 0.8 1.2 2.42.01.6 3.22.8
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
040248 rev/sec
5/150
10/150
66 66 68 68 60 60
67 66 66
68 68 68 68 68
65 61 61
72 72 71 70 69
35˚30˚25˚20˚ 35˚30˚25˚20˚
dBW
1.51.00.750.5 2.0 AkW1.51.00.750.5 2.0 AkW
2.01.0 1.5 2.5 AkW2.01.0 1.5 2.5 AkW
35̊35̊
Blade angleBlade angle
Blade angleBlade angle
Absorbed kW
dB(A)@3m
30o25o20o15o
0.2 0.4 0.6 1.2 1.41.00.8 1.6
81818182
10̊ 30̊25̊20̊15̊
10̊ 40̊30̊25̊20̊15̊
00
40
80
120
160
5/150
10/150
040424 rev/sec
0.30.1 0.2 0.4 AkW
0.150.150.1
qV-Volume flow, m3/s
2.0 Ak2.0 AkWp S
F-Fa
n st
atic
pre
ssur
e, P
a
51 51 51 51 52 52
50 50 52 51 49 55
49 49 50 50 48
56 56 56 56 52 52
54 54
0.30.1 0.2 0.4 AkW
35̊35̊
35̊35̊ 40̊40̊Blade angleBlade angle
Blade angleBlade angle
P Fd
Absorbed kW
dB(A)@3m
P Fd
0.2 0.4 1.00.80.60
10˚ 35̊30̊2 5̊20̊15̊
5/150
10/150
040616 rev/sec
0
60
80
20
40
0.04 0.08 0.12 AkW0.12 AkW
0.02 0.04 0.06 0.08 AkW
p SF-F
an s
tatic
pre
ssur
e, P
a
qV-Volume flow, m3/s
10̊ 35̊ 40̊30˚30˚25˚20˚15̊
48 48 48 48 47 47
48 48 47 46 45 45
46 46 45 45 41
45 45
48 48 48 47 46 46
0.04 0.08
Blade angle Blade angle
Blade angle Blade angle
40̊40̊
0.02 0.04 0.06 0.08 AkW
Absorbed kW
dB(A)@3m
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 13
AXIAL FLOW FANS PERFORMANCE DATA © FANTECH 2016
C
Size 500
C-14
200
400
1000
800
600
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
01.0 2.0 3.0 6.05.04.0
10˚ 30˚25˚20˚15˚
P Fd
050248 rev/sec
5/150
10/150
3.0 AkW2.01.5
10̊ 25̊20̊15̊
73 73 74 74
74 73 73 72
76 76 75 75
78 78 81
3.0 3.5 AkW2.52.5 3.5 AkW
3.0 AkW2.01.5
Blade angle Blade angle
Blade angle Blade angle
Absorbed kW
dB(A)@3m
0
40
80
P Fd
120
240
280
200
160
7
0.50 1.0 1.5 2.52.0 3.0
40˚10˚ 25˚15˚
40˚10˚
35˚30˚25˚20˚15˚
050424 rev/sec
5/150
10/150
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
58 58 57 57 55 56
58 57 58 57 57
58 58 59 59 57
57
64 64 65 65 64 64
62 63
Blade angleBlade angle
Blade angleBlade angle
40˚35˚35˚30˚30˚20˚20˚
0.6 AkW0.40.2 0.6 AkW0.40.2
1.0 AkW0.750.50.25 1.0 AkW0.750.50.25
Absorbed kW
dB(A)@3m
0.40 0.8 1.61.2 2.00
20
40
80
60P Fd
7
Blade angle 40˚10̊ 35̊30˚25̊20̊15̊
120
100
050616 rev/sec
5/150
10/150
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
40˚35̊10̊ 30˚25̊20̊15̊
53 53 53 53 52 52
53 53 52 51 51
56
51 51
56 57 57 57 57
Blade angle Blade angle
0.04 0.16 AkW0.16 AkW0.120.120.080.080.04
53 53 51 51 50
10̊ 30˚25̊20̊15̊
0.3 AkW0.20.1 0.3 AkW0.20.1
Absorbed kW
dB(A)@3m
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
AXIAL FLOW FANS PERFORMANCE DATAV
BS848:Part 1, 1980Part 2 1985
Type D Installation
Axial Flow Fans_18.qxd 16/11/2015 3:32 PM Page 14
© FANTECH 2016 C-15AXIAL FLOW FANS PERFORMANCE DATA
C
Size 560V
BS848:Part 1, 1980
Part 2 1985
Type D Installation
P Fd
7
200
400
600
800
101
103
101
103
01.0 2.0 3.0 5.0 6.0 7.0 8.04.00
7
15˚
1000
056248 rev/sec
5/150
7/2506.0 8.0 10.0 AkW6.0 8.0 10.0 AkW
Blade angle 10˚
Blade angle 35̊35̊30̊30̊25̊25̊40˚
15˚10˚
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
76 76
74 73
76 76
81
77
79 79 77 78
77 74 75
81 78 79 75
Blade angle 10˚
Blade angle
35˚30˚
3.0 5.03.0 4.04.0 5.0
20˚20˚
2.02.0 3.0 AkW3.0 AkW
Absorbed kW
dB(A)@3m
0
20
40
60
120
140
100
80
25o20o15o
P Fd
86
878482
82
82
84
0.4 0.8 1.2 2.42.01.6 2.80q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
Blade angle
10̊ 30̊25̊15̊
056616 rev/sec
0.3 AkW0.20.1 0.3 AkW0.20.1
0.6 AkW0.4 0.50.30.2 0.6 AkW0.4 0.50.30.214/250
20̊20̊ 35̊35̊ 40̊40̊
10̊ 30̊30̊25̊25̊15̊ 20̊20̊ 35̊35̊ 40̊
55 55 56 56 57
56 55 56 55 55
56 56 56 56 56 58 56 58
59 59 59 59 53 53
Absorbed kW
dB(A)@3m
5/150
0
40
80
120
240
280
200
160
30o25o20o15o
P Fd
91
949189
87
89
89
1.0 2.0 3.0 4.00
10̊ 15̊ 25̊20̊
320
056424 rev/sec
5/150
14/2502.0 AkW2.0 AkW1.51.5
0.750.75
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
Blade angle 40̊15˚ 35˚35˚25˚
1.0 AkW1.0 AkW0.50.50.250.25
58 58 59 59 59 59
57 56 59 58
61 61 63 61 61
58 64
69 69 68
67 65 66
68 62 63
35˚ ˚4035˚
1.00.5 1.00.5
10˚ 30˚20˚10˚ 30˚20˚
Absorbed kW
dB(A)@3m
3030̊̊30̊
AXIAL FLOW FANS PERFORMANCE DATA
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 15
AXIAL FLOW FANS PERFORMANCE DATA © FANTECH 2016
C
C-16
01.0 2.0 3.0 6.05.04.0 7.0
50
100
150
300
400
350
250
200
0
93
95
9393
92
93
93
40̊
30o25o20o15o
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle 10̊ 25̊20̊
10̊ 30̊20̊15̊
5/150
14/250
P Fd
063424 rev/sec
3.5 AkW3.02.52.01.51.0 3.5 AkW3.02.52.01.51.0
1.5 AkW1.00.750.5 1.5 AkW1.00.750.5
25̊25̊ 35̊35̊
35̊35̊ 40˚40˚30̊30̊15̊15̊
61 61 64 64 64 64
62 61 62 63 63
66 66 66 67 66
73 73 71 71 68 68
72 69 69
71 71
Absorbed kW
dB(A)@3m
Size 630
02.0 4.0 6.0 12.010.08.0 14.0
200
400
600
1200
1600
1400
1000
800
0
P Fd
7
112
114111
110
109
108
109
110
30o25o20o15o 40˚10˚ 35˚30˚25˚20̊15˚
063248 rev/sec
7/250
14/250 16.0 AkW8.0 12.06.0 16.0 AkW8.0 12.06.0
16.0 AkW4.0 8.0 12.0 16.0 AkW4.0 8.0 12.0
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
Blade angle
82
10˚10˚ 25˚25˚20˚15˚
85 85 82 83 79
75 82 8081 82 79
82 82 8283 84 81
89 89 89 89
Absorbed kW
dB(A)@3m
01.0 2.0 3.0 4.0
20
40
60
120
180
160
140
100
80
0
P Fd
7
88 8486
10̊ 35˚30̊25˚15˚
40˚10˚ 35˚30˚25˚20˚15˚
063616 rev/sec
1.0 AkW0.5 0.750.25 1.0 AkW0.5 0.750.25
5/150
0.4 Ak 0.2 0.30.1 0.4 AkW0.2 0.30.1
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
14/250
58 58 60 60 59
57 57 58 58 58
58 58 60 60 59 59
69
59 59 59
62 62 61 61 58 58
Absorbed kW
dB(A)@3m
Blade angle35˚
20˚20˚ 40˚40˚0
20
40
100
80
60
P Fd
79
82 79
78
81
o 30o25o20o15o
0.5 1.0 1.5 3.02.52.0 3.50
063812 rev/sec
25˚20˚10˚
14/250
5/150
0.4 AkW0.2 0.30.1 0.4 AkW0.2 0.30.1
0.2 0.2 AkW0.10.1 0.150.150.050.05
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
40˚25˚20˚15˚
5353 55 55 54
5152 53 53 53
5353 55 55 54 54
52 52 53
56 56 55 56 51 52
Absorbed kW
dB(A)@3m
40˚35˚30˚15˚ 40˚35˚30˚15˚Blade angle
Blade angle35˚30˚10˚ 35˚30˚10˚ Blade angle
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
AXIAL FLOW FANS PERFORMANCE DATAV
BS848:Part 1, 1980
Part 2 1985
Type D Installation
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 16
© FANTECH 2016 C-17AXIAL FLOW FANS PERFORMANCE DATA
C
Size 710V
BS848:Part 1, 1980
Part 2 1985
Type D Installation
0
40
80
120
160
200
P Fd
90
93
9290
89
90
91
10o 25o20o15o
0 1.0 2.0 3.0 4.0 5.0 6.0q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle 40̊10˚ 35̊30˚25˚20˚15˚
5/150
14/250
071616 rev/sec
1.6 AkW0.8 1.20.4 1.6 AkW0.8 1.20.4
0.6 A 0.40.2 0.6 AkW0.40.2
10˚10˚ 35˚35˚
59 59 59 59 60
59 59 58 57 58
60 60 62 62 62 63 64 65
66 66 64 64 63 63
65 67
Absorbed kW
dB(A)@3m
40˚30˚25˚20˚15˚ Blade angle40˚30˚25˚20˚15˚ Blade angle
0
100
200
300
400
P Fd
97 999797
Blade angle 10o 30o25o20o15o
0 2.0 4.0 6.0 8.0 10.0
99 9597
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
10210098
35̊20˚15˚10˚
071424 rev/sec
14/250
5/150
5.0 AkW2.0 3.0 4.01.5 5.0 AkW2.0 3.0 4.01.5
1.0 1.5 2.5 AkW2.00.5 2.5 AkW2.00.5
40̊35̊30̊25˚20˚10˚ 15̊
70 69 68 69
63 63 64 6564
63 63 66 6467
75 75 73 74 71
75 73 74
73 73
71
Absorbed kW
dB(A)@3m
Blade angle Blade angle
40̊30˚25˚ 40̊30˚25˚
35̊
P Fd
87 8486
7
Blade angle
Blade angle
40̊10̊ 35̊30̊25̊20̊15̊0
20
40
60
80
100
120
0 1.0 2.0 3.0 4.0 5.0
071812 rev/sec
14/250
5/150
0.4 0.6 AkW0.2 0.6 AkW0.2
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
40̊10̊ 35̊30̊25̊20̊15̊
0.3 A 0.20.20.1 0.3 AkW
54 54 54 54 56
54 54 53 53 53
55 55 57 57 55 57 58 59
57 58 57 58 57 57
60 61
Absorbed kW
dB(A)@3m
56
AXIAL FLOW FANS PERFORMANCE DATA
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 17
AXIAL FLOW FANS PERFORMANCE DATAC-18 © FANTECH 2016
C
0
100
200
300
P Fd
30o25o20o15o
0 1 2 3 4 5 6 7 8 9
86
85
9391
90
89
88
87
86
85
84
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
Blade angle
40˚40˚10˚ 35˚25˚20˚
40˚10˚ 30˚20˚
080616 rev/sec
6/255
12/3503.0 AkW2.01.0
1.00.5 2.0 AkW1.5
61
61 61 60 62 62 62
60 60 62 63 62 63
61 61 63 62 63
64 63 62 62 62 62
61
Absorbed kW
dB(A)@3m
3.0 AkW2.0
35˚25˚15˚ 35˚25˚15˚
0.5 1.0 1.5 2.0 AkW
30˚15˚ 30˚15˚
P Fd
Blade angle
Blade
30o25o20o15o
2 4 6 8 10 12 14
94
93
99
98
97
96
95
94
94
92
10̊ 35̊30̊25̊20̊15̊0
100
200
300
400
500
600
700
0
12/350
6/255
080424 rev/sec
10 AkW10 AkW8.06.04.0
7.0 Ak 7.0 AkW5.05.05.05.03.03.01.51.5
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
angle40̊10̊ 35̊30̊25̊20̊15̊
40̊40̊
70 70 69 70 73 73
70 70 69 70 71 72
74 74 71 71 72 73
73 73 71 71 69 69
Absorbed kW
dB(A)@3m
8.0
40̊ angle
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle0
40
80
120
160
0 1 2 3 4 5 6 7
Blade angle
40̊
dBW
40̊10̊ 25̊15̊
P Fd
35̊10̊ 25̊15̊ 30̊ 35̊20̊
6/255
12/350
080812 rev/sec
1.00.4 0.6 0.8 1.4 AkW1.20.4 0.6 0.8 1.4 AkW1.2
0.2 0.4 0.8 AkW
54 55 55 56 56 56
54 54 55 57 56 56
53 53 57 58 57 57
58 57 55 56 55 55
40̊40̊
1.0
0.4 0.8 AkW0.60.6
20̊20̊ 35̊35̊30̊30̊
Absorbed kW
dB(A)@3m
0.20.20.2
Size 800
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
AXIAL FLOW FANS PERFORMANCE DATA
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 18
© FANTECH 2016 C-19AXIAL FLOW FANS PERFORMANCE DATA
C
AXIAL FLOW FANS PERFORMANCE DATA Size 1000
P Fd
Blade angle
Blade angle
2 4 6 8 10 12 14 160
50
100
150
200
250
300
350
400
0q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
40̊10̊ 35̊30̊25̊
40̊40̊10̊ 25̊20̊15̊
12/350
6/255
100616 rev/sec
3.0 4.0 5.0 6.02.0 7.0 AkW
Absorbed kW
3.0 4.0 5.0 6.02.0 7.0 AkW
2.0 3.01.0 4.0 AkW2.0 3.01.0 4.0 AkW
67 67 67 68 68 69
67 68 65 67 68 69
71 71 69 69 70
67 69
7071717273 70
20̊20̊15̊15̊
35̊35̊30̊30̊
dB(A)@3m
P Fd
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
Blade angle
40̊10̊ 35̊25̊15̊
40̊25̊ 35̊25̊15̊
900
0
100
200
300
400
500
600
700
800
0 5 10 15 20 25
100424 rev/sec
12/350
6/255
Absorbed kW
5.05.0 20.0 AkW20.0 AkW15.015.0
6.0 12.0 AkW9.03.0 6.0 12.0 AkW9.03.0
76
76 74 76 78 79
81 7680 77 79
77
76 75 75 79 79
77 78
83
84 84 81 81 79 79
20̊20̊ 30̊30̊
10.010.0
10̊10̊ 20̊20̊ 30̊30̊
dB(A)@3m
0
40
80
120
160
200
240
P Fd
0 2 4 6 8 10 12
Blade angle
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
40̊10̊ 20̊
Blade angle 40˚10̊ 35̊ 35̊ 30̊30̊25̊25̊20̊20̊15̊15̊
6/255
12/350
100812 rev/sec
Absorbed kW
1.51.0 3.0 AkW2.0 2.51.51.0 3.0 AkW2.0 2.5
1.00.5 2.0 AkW1.51.00.5 2.0 AkW1.5
61 61
61 61 61 63 63
63
63 6363 63 64
63
61 63 63
59 60
65 6265 63 63 62
35̊ 35̊ 30̊30̊25̊25̊15̊15̊
dB(A)@3m
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Axial Flow Fans_18.qxd 16/11/2015 3:32 PM Page 19
60 AkW
AXIAL FLOW FANS PERFORMANCE DATAC-20 © FANTECH 2016
C
0
250
500
750
1000
1250
1500
1800
P Fd
0 8 16 24 32 40 48q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle 10˚ 15˚ 20˚ 25˚ 30˚ 40˚
10˚ 15˚ 20˚
125424 rev/sec
12/550
9/350
Absorbed kW
4020 30 4020 30 60 AkW60 AkW
81
87 87 83 83 84 84
88 88 84 85 86
82 81 81 87 86
87868889
dBW
25˚25˚ 30̊ Blade angle
2010 30 40 50 AkW2010 30 40 50 AkW
35˚35˚
dB(A)@3m
0
100
200
300
400
500
600
700
P Fd
0 6 12 18 24 30 36
101
100
106105103
102
101
100
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
78 76 77
40̊10̊ 15̊
800
9/350
12/550
125616 rev/sec
Absorbed kW
7.55 7.55.0 15.015.0 AkWAkW12.5
20̊20̊ 25̊25̊ 30̊30̊ 35̊35̊
Blade angle Blade angle 40̊40̊10̊10̊ 15̊15̊ 20̊20̊ 25̊25̊ 30̊30̊ 35̊35̊
76757777 77 78
75
7979 74
7477
7675
77 75 75
80 78 7879 78 79
10.07.5 15.015.010.07.5 15.0 25.020.0
dB(A)@3m
30.0 AkW
10.0 15.0 AkW
94
93
9997
96
96
95
94
93
0
100
200
300
400
P Fd
10o 30o25oo15o
0 4 8 12 16 20 24q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
68
25˚15˚ 25˚ 35˚ 40̊
Blade angle 10̊ 15˚ 20˚ 25˚ 30˚ 35˚
12/550
9/350
125812 rev/sec
Absorbed kW
68 69 68 69 67 68
70 71 67 68 66 67
72 72 69 69 6768
71 71 69 69 69 69
10̊10̊ 20˚20˚ 30˚30˚
2.01.0 6.0 AkW3.0 4.0 5.02.01.0 6.0 AkW3.0 4.0 5.0
6.04.0 12.0 AkW8.0 10.06.04.0 12.0 AkW8.0 10.0
20˚ 25˚ 30˚ 35˚ 40˚40˚
dB(A)@3m
Size 1250 AXIAL FLOW FANS PERFORMANCE DATA
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 20
© FANTECH 2016 C-21AXIAL FLOW FANS PERFORMANCE DATA
C
C-21
0
100
200
300
400
500
600
700
800
P Fd
0 8 16 24 32 40 48
140616 rev/sec
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle 40̊10̊ 35̊30̊25̊20̊15̊
Blade angle 10̊ 35̊30̊25̊15̊
12/350
12/550
Absorbed kW
75 81 79 81 79 80
80 80
83
79 80 80 80
83 82 83 8384
84 84 82 8182 81
20̊ 40̊40̊20̊
20.0 30.0 40.0 AkW10.0 20.0 30.0 40.0 AkW10.0
15.0 20.0 25.0 AkW10.05.0 15.0 20.0 25.0 AkW10.05.0
dB(A)@3m
110
112
113110
112
0
250
500
750
1000
1250
1500
1750
2000
P Fd
0 10 20 30 40 50 60 70q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
Blade angle
d
10̊ 15̊
10̊ 25̊20̊15̊
60.060.012/550
6/550
140424 rev/sec
Absorbed kWDo not use GRP
88 88 87
87 87 86
89 89 86
92 92 89
40.040.0 80.0 AkW80.0 AkW
20.0 40.0 AkW20.0 40.0 AkW
6060 AkW AkW
25̊2 ˚20̊ 25̊
dB(A)@3m
0
50
100
150
200
250
300
350
400
450
P Fd
0 6 12 18 24 30 36q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
12/350
140812 rev/sec
12/550
10̊ 25˚ 30̊ 40̊
Blade angle 10̊ 15˚ 20˚ 30̊ 35˚ 40˚
Absorbed kW
76 76 71 71 73 73
75 75 74 75 71 71
76 76
75 75 73 74 71 71
71
75 74 69 69
15˚ 20˚ 35˚15˚ 20˚ 35˚
10.0 AkW4.0 6.0 8.0 10.0 AkW2.0 4.0 6.0 8.0
20.0 AkW4.0 8.0 12.0 16.0 20.0 AkW4.0 8.0 12.0 16.0
25˚25˚
dB(A)@3m
Size 1400
15.0 AkW
15.0
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
AXIAL FLOW FANS PERFORMANCE DATA
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 21
AXIAL FLOW FANS PERFORMANCE DATA © FANTECH 2016
C
C-22
Size 1600 AXIAL FLOW FANS PERFORMANCE DATA
Blade angle
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
P Fd
10̊ 25˚ 30̊ 35˚
40˚
0
100
200
300
400
500
600
0 10 20 30 40 50
12/550
6/550
160812 rev/sec
Blade angle 10̊ 15˚ ˚ 30̊
75
7576
75
7377
767677777878
74
10.0 15.0 25.0 30.0 35.0 AkW10.0 15.0 25.0 30.0 35.0 AkW
7.07.0 10.010.0 AkWAkW
15˚ 20̊15˚ 20̊
Absorbed kW
dB(A)@3m
20̊20̊
74
74 74 75 75
252525
7.0 10.0 AkW
76
4.04.04.0
96
94
9896
95
95
94
P Fd
10o 30o25o20o15o
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
40̊10̊ 35̊30̊25̊20̊15̊
40̊
10̊ 30̊15̊
0
50
100
150
200
250
300
350
400
0 5 10 15 20 25 30 35 40
160110 rev/sec
12/550
6/400
70 70 70 71 68 70
69 69 70 71 69 70
70 70 71 71 72
71
71
73 73 73 73 73 72
70
72
Blade angle 35̊25̊20̊ Blade angle 35̊25̊20̊
4.04.0 8.08.0 12.012.0 16.0 AkW16.0 AkW
2.0 4.0 6.0 8.0 AkW2.0 4.0 6.0 8.0 AkW
Blade angle Blade angle
Absorbed kW
dB(A)@3m
105
106
107105
106
0
100
200
300
400
500
600
700
800
900
1000
10o 25o20o15o
0 10 20 30 40 50 60 70
10̊
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
160616 rev/sec
12/550
6/400
10̊ 15˚ 20̊ 25˚Blade angle
81 83
82 82 82
84 82
86 85 85
81 81
80
82
15˚ 20̊ 25˚15˚ 20̊ 25˚ 30̊30̊Blade angle
FdPP
40.0 AkW20.0 30.0
30.0 AkW20.010.0 15.0
40.0 AkW20.0 30.0
30.0 AkW20.010.0 15.0
Absorbed kWDo not use GRP
dB(A)@3m
83
Blade angle
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 22
© FANTECH 2016 C-23AXIAL FLOW FANS PERFORMANCE DATA
C
0
100
200
300
400
500
600
700
800
900
1000
1100
P Fd
10o 20o15o
0 20 40 60 80 100
110
111
110
111
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
10̊Blade angle 20̊15̊
10̊ Blade angle 30˚
12/550
6/400
180616 rev/secAbsorbed kW
dB(A)@3m
85 86 84
85
87 84
83
90 87
8988
92 92 91 91 89
87
25̊25̊
10.0 20.020.0 30.0 AkW
20.0 40.0 60.020.0 40.0 60.0 80.0 AkW 80.0 AkW
25̊20̊15̊ 25̊20̊15̊ 35˚35˚
87
10.010.010.0
85
0
100
200
300
400
500
600
P Fd
10o 20o15o
0 10 20 30 40 50 60 70
102
102
102
102
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
10̊Blade angle 25̊15̊
Blade angle 30˚20̊15̊
180812 rev/sec
12/550
6/400
Absorbed kW
dB(A)@3m
82 82 80 80
79 76
82
78 78 79
78 78
75 75 75
78
20̊20̊
10̊ 25̊10̊ 25̊
10.0 20.0 30.0 AkW10.0 20.0 30.0 AkW
10.0 AkW5.05.0 10.0 AkW
0
50
100
150
200
250
300
350
400
P Fd
0 10 20 30 40 50 60
98
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle
10̊ 15˚ 20̊ 25˚ 30̊ 35˚
40̊
Blade angle
180110 rev/sec
12/550 77
74
75
76
77 77 76
AkW
5.0 10.0 15.0 20.0 25.0 AkW5.0 10.0 15.0 20.0 25.0 AkW
˚10̊ 15̊ 25̊ 30̊ 35̊
75
73 75
71 7174
3.03.03.0 6.06.06.0 10.0 AkW10.0 AkW10.0 AkW
74 7373
72
180110 rev/sec
6/550
76
Absorbed kW
dB(A)@3m
20̊
77 76
77
Size 1800
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
AXIAL FLOW FANS PERFORMANCE DATA
Axial Flow Fans_18.qxd 16/11/2015 3:58 PM Page 23
AXIAL FLOW FANS PERFORMANCE DATA
AXIAL FLOW FANS PERFORMANCE DATAC-24 © FANTECH 2016
C
Size 2000
101
100
101
100
0
50
100
150
200
250
300
350
400
450
P Fd
10o 20o15o
0 10 20 30 40 50 60 70 80q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
10̊ 15˚
6/550
12/550
200110 rev/sec
Absorbed kW
dB(A)@3m
78
81
778079
15˚ 20̊ 25˚ 30̊ 35˚ Blade angle 15˚ 20̊ 25˚ 30̊ 35˚ Blade angle
10.0 15.0 20.0 25.0 30.0 AkW10.0 15.0 20.0 25.0 30.0 AkW
25˚25˚Blade angle Blade angle
78
82 79
81 80 80
78 76
78
77 77 77
78 75
10.0
81
220̊20̊
1100̊̊10̊
5.05.05.0
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
P Fd
0 20 40 60 80 100 120 14
116
116
117
115
116
116
qV-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
Blade angle 30̊20̊15̊
Blade angle 10̊ 25̊20̊15̊
200616 rev/sec
6/550
12/550 Absorbed kW
dB(A)@3m
89
90 90 90 86
92 91 86 86
96 96 93
30.0 50.030.0 50.0 75.0 AkW75.0 AkW
30.030.015.0 45.0 60.0 AkW15.0 45.0 60.0 AkW
10̊ 25̊10̊ 25̊
89 87 89
75.0 AkW
105
105
109107
106
105
105
0
100
200
300
400
500
600
700
P Fd
10o o25o20o15o
0 20 40 60 80 100q
V-Volume flow, m3/s
p SF-
Fan
stat
ic p
ress
ure,
Pa
10̊ 40˚30˚20˚
Blade angle 10˚ 15˚ 30˚25˚20˚
12/550
200812 rev/sec
6/550
Absorbed kW
dB(A)@3m
82 82 77 78 78
81 81 77 78 79 79
81 82 80 81 78 79
87 86 84 83 82
84 82
83
35˚35˚
20.0 30.0 40.0 50.0 60.0 AkW20.0 30.0 40.0 50.0 60.0 AkW
10.0 20.0 30.0 40.0 AkW10.0 20.0 30.0 40.0 AkW
15˚ 35˚25˚15˚ 35˚25˚Blade angle
Selecting from these graphs provides a guide only to possible selections. Basic noise level data as well as indicative powerabsorbed figures are incorporated on the graphs. The Fans by Fantech Product Selection Program will show other possible impellercombinations between the two illustrated here for each fan size/speed. The Selection Program will provide full performanceinformation including air flow, pressure, noise levels, absorbed power as well as complete dimensional information.
Higher pitch angles available with aluminium blades
Axial Flow Fans_17.qxd 4/11/2015 2:02 PM Page 24
Recommended