Indications
Contraindications
Stroke
Cerebral palsy
Multiple sclerosis
Spina bifida
Spinal cord injury
Charcot-Marie-Tooth
Other neuromotor deficits
•••••••
Lower limb functional deficits as a result of:
Patient weight greater than 110 kg (240 lb)
Independent adjustment of:
Ankle alignmentPlantarflexion/dorsiflexion range of motionPlantarflexion spring stiffness
Independent ankle alignment range of 10°
(5) high stiffness spring options included with booster spring models (Figure 1)
Compatible with unilateral or bilateral orthotic designs
Features
Product Data Sheet
Adult 2.0 Ankle Joint( 19mm Systems )
Model 3A76 Component Selection
*Important: Thermoplastic unilateral AFOs require Camber Axis Triple Action® Companion Joint, or other free motion ankle joint
FabricationOptions
Thermoplastic
5mm (3/16") Polypropylene Unilateral*
Bilateral5mm (3/16") Polypropylene
Composite
Unilateral
Bilateral
Wet Lamination like Becker BCO Shadow™, Max™ or PrePreg
Wet Lamination like Becker BCO Lite™, Shadow™, Max™ or PrePreg
Patent #10,500,081©2020 Becker Orthopedic Appliance Co.,All rights reserved.Revision 08/01/20
Acorn Regulatory Consultancy Services Limited
Knockmorris Cahir Co. TipperaryIreland, Postcode: E21 R766
P 012 4626 8456 F 012 4626 8648
NORMAL
100 kg / 220 lb
110 kg / 240 lb
No Booster Plantarflexion Resist Booster
3A76-A1* 3A76-A0* 3A76-A23A76-A3
NORMAL
ABNORMAL
ABNORMAL
NORMAL
ABNORMAL
RightLeftRight RightLeft LeftRight
Lateral MedialLateral Medial Lateral MedialLateral Medial
BoosterConfiguration
Unilateral
Side
Order No.
Bilateral
Early StancePhase
Late StancePhase
Leg Left
No Booster Plantarflexion Resist Booster
3A76-A1* 3A76-A0* 3A76-A23A76-A3
RightLeftRight
Lateral MedialLateral Medial
Left RightLeftRight
Lateral MedialLateral Medial
Left
*Only available direct from Becker Orthopedic in some countries
No Yes Yes Yes
X1(low)
X2(moderate)
X4(high)
X5(very high)
High &StandardStandard HighNone
StandardStandardStandard Standard
Booster Required
Bottom Spring
Top Spring
Stiffness
10° 10° 10° 10°Max. ROM
1 2 3 4SPRINGCONFIGURATION
*Figure 1
0
No
X0.5(low)
None
Long ROM
18°
Spring Configurations
Stirrup Options
Y-Stirrup Model 3A76-YR-1 & Model 3A76-YL-1
Accessories
Fabrication Tool KitModel 3A00-FTK
Camber Axis Triple Action® Companion Joint
Model 751-ATA
The fabrication tool kit includes fabrication dummies, alignment axis, attachment hardware and wrenches.
Product Data Sheet
Adult 2.0 Ankle Joint( 19mm Systems )
Patent #10,500,081©2020 Becker Orthopedic Appliance Co.,All rights reserved.Revision 08/01/20
Acorn Regulatory Consultancy Services Limited
Knockmorris Cahir Co. TipperaryIreland, Postcode: E21 R766
P 012 4626 8456 F 012 4626 8648
Medial Stirrup
Models 3A76-MEDR-1 & 3A76-MEDL-1
Lateral Stirrup Models 3A76-LATR-1 &
3A76-LATL-1
Universal Rivet Stirrup
Model 3A76-R-1
*Internal bottom spring under booster is covered with a lifetime warranty for defects in materials and workmanship.
*The Booster Spring Unit cannot be removed from the Triple Action component housing. Doing so will destroy the Booster and void the product warranty.
Recommended