Ferak Ni-Cd battery rangeKPH - KPM - KPL - KPL LM
Total power reliability without compromise
Ferak Ni-Cd battery range – KPH - KPM - KPL - KPL LM – Total power reliability without compromise2
Ferak Ni-Cd batteries for performance, reliability and versatility
Saft Ferak a.s. has over 60 years experience in the design, development, manufacture and through-life service support of nickel-cadmium (Ni-Cd) pocket plate cells and batteriesfor a broad range of railway and general industrial applications where reliability andoptimized life cycle costs are critical.
Saft’s commitment to research and development and innovative engineering ensures that Ferak batteries offer the very latest indesign, quality and industrial process technology. Ferak’s comprehensive service from initial consultancy to volume delivery coversevery requirement from supplying individual batteries for new-build and replacement contracts to managing major turnkey projectsfor fully integrated battery systems.
Comprehensive backup solutions for onboard and trackside signaling
Ferak Ni-Cd batteries provide effectiveonboard and trackside backup power tomeet the safety, security and reliabilitychallenges of today’s railway landscape.Onboard Ferak batteries support vitalservices such as lighting, data andcommunications systems, ventilationand door opening functions as well aselectromagnetic braking.Trackside Ferak Ni-Cd batteries ensuretotal reliability for signaling, levelcrossing and points operation, positivetrain control, security surveillance andtelecommunications equipment.
Reliable and robust batteries forbackup power in stationary applications
Power continuity is absolutely vital for a wide variety of stationary applicationssuch as Uninterruptible Power Supply(UPS) systems, substation switching andtransmission functions, emergency andsecurity systems, industrial fire monitorsand alarms, data centers, process controlinstallations and signaling systems. If themain power source is lost, Ferak backupbatteries support critical systems untilprimary power can be re-established or a controlled shutdown is carried out.
High power for even the most demanding applications
Ferak batteries supply high power fordemanding critical backup applications.For locomotives and DMUs they deliverexceptionally high cranking currentsthat ensure fast and reliable enginestarting, especially in ‘no-idling’operations where train operators requirefrequent stopping and starting to savefuel and reduce noise while cuttingemissions to reduce their CO2 footprint.
Total onboard and trackside reliability for railway applications Stationary applications
BACKUP & STARTING BACKUP
Ferak Ni-Cd battery range – KPH - KPM - KPL - KPL LM – Total power reliability without compromise 3
Ferak Ni-Cd range a wide choiceof capacity and performance
Ferak KPL, KPM, KPH and KPL LowMaintenance batteries are the ideal solutionfor all discharge profiles. Based on Saft’sreliable Ni-Cd pocket plate technology, theyoperate over a wide range of temperatures,resist electrical abuse, shock and vibrations,need only basic maintenance and offeroptimized Total Cost of Ownership (TCO).
Saft Ferak’s single cell portfolio comprises high, medium, low rate discharge types
Range of cells
Capacity
Average topping-up operation
Performance
IEC qualification
Applications
KPH Type
20
14 – 265 Ah
3 - 12 months
For high rate discharge over shortperiods less than 30 minutes
ČSN EN 60 623
Power back-up and starting
KPM Type
22
11 - 375 Ah
3 - 12 months
For varied loads with low and high discharge rate between
20 minutes and 3 hours
ČSN EN 60 623
KPL Type
18
10 - 375 Ah
3 - 12 months
For low rate discharge over longperiod between 1 to 5 hours
ČSN EN 60 623
KPL LM (KPL PR LM) Type
10
100 – 375 Ah
1 - 2 years
For low rate discharge over longperiod between 1 to 5 hours
ČSN EN 62 259
Power back-up
Covering every need - from starting to backup
KPH Type
KPM Type
KPL Type
1 s
1 mn
10 mn
30 mn
Regular maintenance
Discharge time
1 h
5 h
Low maintenanceKPL LM Type
Ferak Ni-Cd battery range – KPH - KPM - KPL - KPL LM – Total power reliability without compromise4
Ferak range’s robust engineering ensures total reliability and long life
Ferak KP Ni-Cd batteriesfeature high qualityconstruction, advancedpocket plate technology anda large electrolyte reserve.This ensures exceptionalreliability with the benefit of total peace of mind andlower operating costs over a long service life.
• Operation over a wide temperaturerange from - 20°C to + 50°C withextremes from - 50°C to + 70°C
• Performs well at low temperature• Resists high temperature aging• Resists electrical abuse and shock and vibration
• Requires only simple maintenance• Easy and inexpensive to install• Ensures over 20 years’ service life at normal operating conditions (+ 25°C)in stationary applications
Features
• Batteries normally supplied inpolypropylene plastic containersassembled into plywood crates
• Crates can be equipped with frontterminals
• Flip-top arresting vents as standard• Optional centralized water filling system• Batteries also supplied in flameretardant or stainless steel containers,assembled in formats to suit particularrequirements
Options for added versatility
1
3
5
7
2
4
6
8
H
W L
1/ Terminal sealThis is mechanically clipped and provides anexcellent seal. This minimizes carbonation deposits.
2/ Flame arresting vent
3/ Cell containerMaterial: translucent polypropylene.
4/ Plate group busConnects the plate tabs with the terminal post. Plate tabs and terminal posts are projection weldedto the plate group bus.
5/ Plate tabSpot welded to the plate side frames, to the upperedge of the pocket plate and to the plate group bus.
6/ PlateHorizontal pockets of double-perforated steel strips.
7/ Separating gridsThese separate the plates and insulate the plateframes from each other. The grids allow freecirculation of electrolyte between the plates.
8/ Plate frameSeals the plate pockets and serves as a currentcollector.
Ferak Ni-Cd battery range – KPH - KPM - KPL - KPL LM – Total power reliability without compromise 5
KPH Range Cell capacities and dimensions
KPH cells - Typical discharge at + 20°C / + 25°C
Cell voltage (V)
Capacity (%)
0,5
0,6
0,7
0,8
0,9
1
1,1
1,2
1,3
1,4
1,5
0 10 20 30 40 50 60 70 80 90 100 110 120
0,2 C51 C52 C53 C55 C5
KPM cells - Typical discharge at + 20°C / + 25°C
Cell voltage (V)
Capacity (%)
0,4
0,5
0,6
0,7
0,8
0,9
1
1,1
1,2
1,3
1,4
0 10 20 30 40 50 60 70 80 90 100 110
0,2 C51 C52 C53 C55 C5
Weight (kg)
1,92,02,23,33,53,74,04,15,75,96,710,911,214,414,915,418,018,018,218,5
Electrolytereserve (ml)
1151101052352302252202154804605709108901060104010201290129012801275
Cell connectionbolt per pole
M10M10M10M10M10M10M10M10M20M20M20
2 x M202 x M202 x M202 x M202 x M202 x M202 x M202 x M202 x M20
H283283283283283283283283360360360360360362362362362362362362
L4646468686868686696983103103128 128128156156156156
W
Dimensions (mm)
8686868686868686136136136164164164164164164164164164
Capacity (Ah)
14182226343846506580100125150170190210220245255265
Cell type
KPH 14 PKPH 18 PKPH 22 PKPH 26 PKPH 34 PKPH 38 PKPH 46 PKPH 50 PKPH 65 PKPH 80 PKPH 100 PKPH 125 PKPH 150 PKPH 170 PKPH 190 PKPH 210 PKPH 220 PKPH 245 PKPH 255 PKPH 265 P
KPM Range Cell capacities and dimensionsWeight (kg)
1,71,92,03,03,23,43,63,75,86,06,26,78,18,310,610,911,311,614,514,815,115,4
Electrolytereserve (ml)
12011811524023523323022543042041047058057075074073072010101005995985
Cell connectionbolt per pole
M10M10M10M10M10M10M10M10M20M20M20M20M20M20M20M20M20M20M20M20M20M20
H283283283283283283283283328328328312328328363363363363360360360360
L464646868686868683838393112112 93939393130130130130
W
Dimensions (mm)
8686868686868686136136136136136136192192192192198198198198
Capacity (Ah)
11182532384550608095105120140160180210230250280300340375
Cell type
KPM 11 PKPM 18 PKPM 25 PKPM 32 PKPM 38 PKPM 45 PKPM 50 PKPM 60 PKPM 80 PKPM 95 PKPM 105 PKPM 120 PKPM 140 PKPM 160 PKPM 180 PKPM 210 PKPM 230 PKPM 250 PKPM 280 PKPM 300 PKPM 340 PKPM 375 P
Ferak Ni-Cd battery range – KPH - KPM - KPL - KPL LM – Total power reliability without compromise6
KPL Range Cell capacities and dimensions
KPL cells - Typical discharge at + 20°C / + 25°C
Cell voltage (V)
Capacity (%)
0,4
0,5
0,6
0,7
0,8
0,9
1
1,1
1,2
1,3
1,4
0 10 20 30 40 50 60 70 80 90 100 110
0,2 C50,5 C51 C52 C5
KPL LM cells - Typical discharge at + 20°C / + 25°C
Cell voltage (V)
Capacity (%)
0,4
0,5
0,6
0,7
0,8
0,9
1
1,1
1,2
1,3
1,4
0 10 20 30 40 50 60 70 80 90 100 110
0,2 C50,5 C51 C52 C5
Weight (kg)
0,91,11,81,92,82,93,15,75,86,46,76,98,58,712,512,713,013,3
Electrolytereserve (ml)
80801751702152502104804806106005906606501070106010501040
Cell connectionbolt per pole
M6M6M6M6M10M10M10M10M10M20M20M20M20M20M20M20M20M20
H173173233233288267288365365328328328365365365365365365
L353545455460547575112112112103103156156156156
W
Dimensions (mm)
122122122122122136122136136136136136164164164164164164
Capacity (Ah)
10203040556070100125140160180220250280300350375
Cell type
KPL 10 PKPL 20 PKPL 30 PKPL 40 PKPL 55 PKPL 60 PKPL 70 PKPL 100 PKPL 125 PKPL 140 PKPL 160 PKPL 180 PKPL 220 PKPL 250 PKPL 280 PKPL 300 PKPL 350 PKPL 375 P
KPL LM (KPL PR LM) Range Cell capacities and dimensionsWeight (kg)
5,45,87,79,911,414,615,79,113,413,6
Electrolytereserve (ml)
370350540990960930890600970950
Cell connectionbolt per pole
M10M10M20M20M20M20M20M20M20M20
H365365328360360360360365365365
L7575112130130130130103156156
W
Dimensions (mm)
136136136198198198198164164164
Capacity (Ah)
100125160210250300375250300375
Cell type
KPL 100 P LMKPL 125 P LM KPL 160 P LMKPL 210 P LMKPL 250 P LMKPL 300 P LMKPL 375 P LMKPL 250 PR LMKPL 300 PR LMKPL 375 PR LM
Topping up intervals multiplied by three compared to standard pocket plate batteries
Standard pocket plate 1KPL LM 3
Ferak Ni-Cd battery range – KPH - KPM - KPL - KPL LM – Total power reliability without compromise 7
Railway battery crate configurations
Ferak Ni-Cd batteries are designed in full compliancewith the highest quality, safety and environmental standards
Ferak cells for railway applications are generally supplied in crates in a variety of configurationsto suit different customer needs, including: plywood, full plastic and steel-plastic.
KPL 10 P - 375 P100 P LM - 375 P LM250 PR LM - 375 PR LM
KPM 11 P - 375 P
KPH 14 P - 265 P
Plywood with handles Plywood with handles and terminals
Full plastic Full plastic with terminals
Steel-plastic Strapped
Electrical characteristics:• Certified ČSN EN 60623 and ČSN EN 62259
Shock & vibration characteristics:• Designed to comply with: ČSN EN 61 373
Quality:• ISO 9001 and ISO 14001
• Saft world class continuous programme
Environment & Recycling:• Fully recyclable
• RoHS – Although batteries and accumulators are not within the scope of the RoHS
directive, Saft has taken voluntary measures to make sure that the substances forbidden
by RoHS are not present in the battery, with the exception of the electro-chemical core.
• REACH – The Saft Group has adopted internal procedures to ensure conformity
with the European REACH (Registration, Evaluation, Authorisation and Restriction
of Chemical Substances) Regulation.
KPL 10 P - 375 P100 P LM - 375 P LM250 PR LM - 375 PR LM
KPM 11 P - 375 P
KPH 14 P - 150 P
KPM 80 P - 160 P
KPH 100 P
KPL 10 P - 70 P
KPM 11 P - 60 P
KPH 14 P- 50 P
KPL 220 P - 375 P250 PR LM - 375 PR LM
KPH 125 P - 265 P
KPL 210 P LM - 375 P LM
KPM 280 P - 375 P
As part of this environmentalcommitment, Saft prioritises the use ofrecycled raw materials over virgin rawmaterials in all manufacturing processes.We also strive, year on year, to reduce airand water emissions from our plants, aswell as minimizing water usage, reducingconsumption of fossil energy consumptionand associated CO2 emissions, andensuring that all our customers haveaccess to recycling solutions for their
spent batteries. To facilitate the end-of-lifecollection and recycling of industrialbatteries, including our nickel & lithium-based technologies, Saft has developedwell-established partnerships withcollection companies in most EUcountries, in North America and in manyother countries worldwide. This collectionnetwork receives spent batteries from ourcustomers and dispatches them to fullyapproved recycling facilities, in compliance
with the laws governing trans-boundarywaste shipments. This collection networkis currently undergoing minor adaptationsto meet the requirements of the EUbatteries directive. A list of our batterycollection points is available on our website. In other countries, Saft will assistanyone using our batteries in findingenvironmentally sound recycling solutions.Please contact your sales representativefor further information.
Saft is committed to the highest standards of environmental stewardship
Document N° 25005-2-0915Edition: September 2015
Data in this document is subject to change without noticeand becomes contractual only after written confirmation.
Photo credits: Saft, Fotolia – R398/2Printed on FSC paper© Saft – Société par Actions Simplifiée au capital de 31 944 000 €RCS Bobigny B 383 703 873
Saft Ferak a.s.Pekařská 12 - 155 00 Praha 5Czech RepublicTel.: +420 257 013 260 Fax: +420 257 013 261praha@saftbatteries.com
Saft Ferak a.s.Raškovice 247 - 739 04 PražmoCzech Republic Tel.: +420 558 426 302Fax: +420 558 426 301raskovice@saftbatteries.com www.saft-ferak.cz
Recommended