View
40
Download
0
Category
Preview:
Citation preview
SECURITY/LIGHTBOLLARDS
FDC CONNECTION
UTILITY POLE
BUILDING SIGN
TRANSFORMER
DATA UTILITYVAULT
FLAGPOLE
TRANSFORMER
FLAGPOLE
SL1B
SL1B
SL1C
SL1A
SL3
SL3
SL3
SL3
SL3
SL3
SL3
SL3
SL3
SL3
SL1A
SL1B
SL1A SL1A
SL5
SL4
SL4
SL4
SL4
A-23
SL1CA-23
A-23
A-23
A-23
A-23
A-23
A-23
A-21
A-21
A-21
A-21
A-21
A-21
B-19
B-19
B-19
B-19
B-19
B-19
B-19
B-19
B-19
B-19
1CC00
1CC00
CUSTOMER SPLICEPOINT
J
J
4
3
1
2
B - 25
B - 27
1
6
5
5
6
1
1
A
LSW Eng in e e r sR I Z O N A, I N C O R P O R A T DE
www.lswphx.com Project No.FacsimileTelephone
Phoenix, Arizona 850212333 West Northern Avenue 602.249.1320
602.336.3276
© LSW Engineers Arizona, Inc.
SHEET TITLE:
APPROVED BY:
PROJECT NO.:
DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
5240 North 16th Street, Suite 101Phoenix, Arizona 85016Telephone: (602) 279-4373Fax: (602) 279-9110
A Limited Liability Company© Copyright 2017
2018-031.000
20186/1
1/2
01
8 8
:24:3
8 A
MC
:\R
evit L
oca
l F
iles\1
803
1-M
EP
17\1
803
1-M
EP
17-b
ram
os.r
vt
E1.1
P2017.114
05-4-2018
RFR/JPS
RFR
AJB
Pin
al C
ount
y - S
an T
anJu
stic
e of
the
Pea
ce C
ourt
s36
55 H
unt H
wy,
Que
en C
reek
, AZ
8514
2
ELECTRICALSITE PLAN
100% CONSTRUCTION DOCUMENTS
1" = 20'-0"1
ELECTRICAL SITE PLAN
1. ALL EXTERIOR LIGHTING CONTROLS SHALL BE CONTROLLED VIA TIME CLOCK PER PINAL COUNTY LIGHTING ORDINANCES.
GENERAL NOTES ( )##
1. PROVIDE 66"x90"x6" SRP UTILITY TRANSFORMER PAD WITH 5/8" DIAMETERx96" GROUND ROD AND (3) BARRIER POSTS. COORDINATE EXACT REQUIREMENTS WITH SRP CONSTRUCTION DRAWINGS.
2. PROVIDE (3) 3" CONDUITS FOR UTILITY PRIMARY FROM EXISTING PAD-MOUNTED SWITCH TO NEW UTILITY TRANSFORMER. COORDINATE EXACT REQUIREMENTS WITH SRP CONSTRUCTION DRAWINGS.
3. PROVIDE (3) 3" CONDUITS FOR UTILITY SERVICE FEEDERS FROM NEW ULTILITY TRANSFORMER TO BUILDING SES. COORDINATE EXACT REQUIREMENTS WITH SRP CONSTRUCTION DRAWINGS.
4. PROVIDE (2) 3" CONDUITS FOR TELECOMMUNICATIONS SERVICE FROM UTILITY POLE TO IT 128.
5. PROVIDE 120V, 1PH CONNECTION TO AUTOMATIC BARRIER GATE.
6. PROVIDE (1) 1" CONDUIT ROUTED UNDERGROUND FROM IT ROOM TO GATE CARD READER.
KEYED NOTES ( )##
NO. REVISION DATE
1 UTILITYCOORDINATION
06/11/2018
1
06.11
.18
43861
ADAM J.BAGBY
CE
R
T I F IC AT E
NO
.
Re
gis
tere
dP
rofessional Engineer
(Ele
ct ri c
al)
EXPIRES: 03/31/21
UP
F
J
J
J
J
T
J
T J
1
A
B
2 3
100ENTRY PATIO
102LOBBY
103INTERVIEW ROOM
109INTERVIEW ROOM
107MEN'S RESTROOM
110INTERVIEW ROOM
108VESTIBULE
111PRIMARY COURTROOM
128IT
130
SECONDARYCOURTROOM
125WORKSTATIONS
126CHIEF CLERK
123BREAK ROOM
121FILE STORAGE
120JUDGE'S OFFICE
118RESTROOM
117RESTROOM 114
HOLDING113
HOLDING
105WOMEN'S RESTROOM
106JANITOR'S CLOSET
104INTERVIEW ROOM
131RECEPTION
115HALLWAY
127PRINT/COPY
134ELECTRICAL
132EXIT VESTIBULE
124AV
116JURY
119STAFF ENTRY
133FIRE RISER
135CHASE
SES
GFI
1CC00
1CC00MF
1CC00MF
1CC00MF
1CC00MF 1CC00MF
1CC00MF 1CC00MF
1CC00MF 1CC00MF
1CC00MF
1CC00MF
1CC00MF
1CC00
1CC00
1CC00
1CC00+72
1CC00MF
1CC00MF1CC00
1CC00
1CC00
1CC00
1CC001CC00
1CC00
1CC00TV+72
1CC00
1CC00+72
1CC00
1CC00V+46
1CC00V+46
1CC00+72
GFI
GFIGFI GFI
3CC00FB 3CC00FB
3CC00FB 3CC00FB
1CC22FB
101SECURITY
122COURTROOM SEATING
136VESTIBULE
CRCR
CRCR
CR
CR
CR
CR
CR
CR
1
F
CR
CR
FACP1CC00
A-25
B-5
B-5
B-5
B-5
B-3 B-3
B-3
B-8
B-8
B-14 B-16
B-18
B-18
B-10 B-12
1CC00
B-13
B-21B-15
1CR00
B-11
B-17B-17 B-19
B-19
B-23
B-1
2
3
3
3
4
4A-7
A-7
A-7
A - 7
4
A-10
A-10
A-10
A-8
A-8
A-8
A-4
A-4
A-4
A-6
A-6
A-6
A-6
A-12A-14
A - 6
A-16A-16 A-16
A-16
A-11A-13
A-15
A-17 A-17
A-15
A-15
A-21A-21
A-23
A-23
A-23
A-21
A-18
A-18 A-18
A-18
A-2
A-2
A-2
A-1
A-3
A-3 A-3
A-5
A-19
A-21
WP WP
WPB-20
B-20 B-20
IU
1
A-2
B-21
A-23
M - 28
B-18
1CC00AV
1CC00AV+92
1CC00AV+84
1CC00AV+92
55
M - 29
B
M
A
5
5
1CC00AV+1061CC00+106
3CR00AV
1CC00+961CC00AV+96
1CR00
1CC00AV
2CR00AV1CR00
1CR002CR00AV
1CR00
1CR00AV+32
1CC00AV+108
77
77
B-23
B-13B-13
B-15
B-23
6
1CR00AV+32
A-11
A-13
A-15
1CR002CR00AV3CR00AV1CR00
1CR00
1CR002CR00AV
1CR00
1CC00
1CC00
5
1CC00
2CC00AV+72 2CC00AV+72
2CC00AV+72
8
T
11
12
8
A-3
13
14
10
10
B-20
A-23
B-6
A-26
B-20
+114"
+72"
+72" +72"
15
+84"
+48"
+72"
GFI
M - 32,34
16
1
A
LSW Eng in e e r sR I Z O N A, I N C O R P O R A T DE
www.lswphx.com Project No.FacsimileTelephone
Phoenix, Arizona 850212333 West Northern Avenue 602.249.1320
602.336.3276
© LSW Engineers Arizona, Inc.
SHEET TITLE:
APPROVED BY:
PROJECT NO.:
DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
5240 North 16th Street, Suite 101Phoenix, Arizona 85016Telephone: (602) 279-4373Fax: (602) 279-9110
A Limited Liability Company© Copyright 2017
2018-031.000
20186/1
1/2
01
8 8
:24:3
9 A
MC
:\R
evit L
oca
l F
iles\1
803
1-M
EP
17\1
803
1-M
EP
17-b
ram
os.r
vt
E4.1
P2017.114
05-4-2018
RFR/JPS
RFR
AJB
Pin
al C
ount
y - S
an T
anJu
stic
e of
the
Pea
ce C
ourt
s36
55 H
unt H
wy,
Que
en C
reek
, AZ
8514
2
ELECTRICALFLOOR PLAN - FIRSTFLOOR
100% CONSTRUCTION DOCUMENTS
NORTH 1/8" = 1'-0"
ELECTRICAL FLOOR PLAN - FIRST FLOOR
1. INTENDED ROUTE OF ELECTRICAL UTILITY CONDUITS. SEE SITE PLAN FOR ADDITIONAL INFORMATION.
2. INTENDED ROUTE OF TELECOMMUNICATION UTILITY CONDUITS. SEE SITE PLAN FOR ADDITIONAL INFORMATION.
3. PROVIDE 12"x12"x4" JUNCTION BOX WITH REMOVABLE COVER AND CABLE ACCESS PASS THROUGH MOUNTED AT 18" AFF FOR CONNECTIVITY TO MODULAR FURNITURE. PROVIDE 2" CONDUIT FROM PULL BOX TO IT 128 IN SLAB.
4. PROVIDE POWER TO MODULAR FURNITURE VIA JUNCTION BOX IN WALL. ROUTE CONDUIT IN SLAB FROM PANELBOARD. CONTRACTOR TO VERIFY FURNITURE CONFIGURATION AND REPORT ANY DISCREPANCIES TO ENGINEER VIA REQUEST FOR INFORMATION.
5. PROVIDE SURFACE MOUNTED DUAL SERVICE RACEWAY (LEGRAND MODEL 4000 SERIES OR SIMILAR) WITH DUAL COVER PLATES FOR POWER AND TECHNOLOGY.
6. PROVIDE 8"x8" PULL BOX WITH ACCESSIBLE COVER PLATES ON BOTH SIDES MOUNTED IN COMMON WALL OF JUDGE'S DESK. TERMINATE CONDUITS FROM AV 124 DIRECTLY INTO BOTTOM OF PULLBOX. PROVIDE FLEXIBLE METAL CONDUIT FROM PULLBOX TO SURFACE RACEWAY.
7. PROVIDE (1) 2" AND (2) 1-1/4" CONDUITS TO 5 GANG FLOOR BOX (LEGRAND EVOLUTION SERIES EFB45 WITH EFB10-23GMB MOUNTING BRACKET). COORDINATE FLOOR BOX COVER WITH ARCHITECT/OWNER.
8. PROVIDE EXTERIOR WALL-MOUNT (AXIS MODEL T91E61) MOUNTED 9'-0" AFG.
9. PROVIDE CONNECTION TO INDOOR UNIT (FLA =0.57A, MCA = 1A, MOCP = 20A) VIA THERMAL RATED TOGGLE SWITCH DISCONNECT.
10. PROVIDE CONNECTION TO HOT WATER PUMP VIA THERMAL RATED TOGGLE SWITCH DISCONNECT.
11. PROVIDE (3) 2" CONDUIT AND (1) 1" CONDUIT SLEEVES FROM IT 128 TO CAVITY UNDERNEATH JUDGE'S DESK.
12. PROVIDE (3) 2" CONDUIT AND (1) 1" CONDUIT SLEEVES FROM AV 124 TO PULLBOX IN MILLWORK. ROUTE CONDUITS IN SLAB.
13. PROVIDE 19" WIDE, 45 RU TWO-POST RACK.14. PROVIDE 6" VERTICAL ORGANIZERS ON EITHER SIDE OF
RACK.15. PROVIDE 120V, 1PH CONNECTION TO IRRIGATION
CONTROLLER. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT.
16. PROVIDE 30-3W-IC CONNECTION TO WATER HEATER (FLA = 21.6A, MCA = 27A, MOCP = 30A) VIA 208V, 30A, 3P, HEAVY DUTY, NEMA 3R DISCONNECT WITH 30A LPN FUSES.
KEYED NOTES ( )##
NO. REVISION DATE
1 UTILITYCOORDINATION
06/11/2018
8' 16'0'
1
06.11
.18
43861
ADAM J.BAGBY
CE
R
T I F IC AT E
NO
.
Re
gis
tere
dP
rofessional Engineer
(Ele
ct ri c
al)
EXPIRES: 03/31/21
400-
4W-IC
125-
4W-IC
125-
4W-IC
MA A B
SRP METERNO. ______
800AF800AT
3P
LSI
SES800A, 208Y/120V, 3Ø, 4W
25,000A SCCR/AIC
INCOMING FROM UTILITY
UNDERGROUNDPULL SECTION
150AF
3P
400AF400AT
3P
150AF125AT
3P
150AF125AT M
TAG FEEDER DESCRIPTION NOTES
FEEDER SCHEDULE
400-4W-IC (2) 2"C., EACH WITH: (3) 3/0 AWG, (1) 3/0 AWG NEUTRAL, AND (1) 2 AWG GND.
125-4W-IC (3) 1/0 AWG, (1) 1/0 AWG NEUTRAL, AND (1) 6 AWG GND IN 2"C.
40-3W-RT (3) 6 AWG, AND (1) 8 AWG GND IN 1"C. †
30-3W-RT (3) 8 AWG, AND (1) 8 AWG GND IN 3/4"C. †
30-3W-IC (3) 10 AWG, AND (1) 10 AWG GND IN 3/4"C.
CONDITION ABBREVIATIONS:
IC INDOOR, CONDUIT IN AIR
NL INDOOR, NON-LINEAR LOADS (NOTE 4)
OA OUTDOOR, 50°C AMBIENT, OTHER THAN ROOFTOPS (NOTE 4)
RT OUTDOOR, 50°C AMBIENT, MIN. 3.5" ABOVE ROOFTOP (NOTE 4)
UG UNDERGROUND (ISOLATED DUCT BANKS ARRANGED PER NEC ANNEX B, FIGURE B.310.2, DETAIL 1, 2, OR 3.)
NOTES
1 AMPACITY ADJUSTMENT BASED ON 90°C AMPACITY IN ACCORD WITH NEC 110.14(C).
● USING "NEXT HIGHER STANDARD OVERCURRENT DEVICE RATING (ABOVE THE AMPACITY OF THECONDUCTORS BEING PROTECTED)" RULE IN ACCORD WITH NEC 240.4(B).
† UPSIZED BASED ON "CIRCULAR MIL AREA OF THE UNGROUNDED CONDUCTORS" PER 250.122(B).
‡ GROUND SIZE "NOT [...] REQUIRED TO BE LARGER THAN THE CIRCUIT CONDUCTORS SUPPLYING THEEQUIPMENT" IN ACCORD WITH NEC 250.122.
Point-to-Point Fault Calculations (based on Bussmann SPD method and tables)
Fault Location (Node description) Conductors U.N.O., Busway (B) Conduit or System 'C' Value Combined Isc Phase: 'f' 'M' Normal Full
F# No. Sets Size Length (ft) (Busway) Type Voltage 'C' Value Begin 1 or 3 Factor Value Isc Fault
1 INCOMING FROM UTILITY + Motor Contribution ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- 37,979
2 SES 3 500 CU 215 Mag (CU) 208 22,185 66,555 37,979 3 1.0204 0.4949 18,797
3 M 2 3/0 CU 53 Mag (CU) 208 12,844 25,688 18,797 3 0.3226 0.7561 14,213
4 A 1 1/0 CU 53 Mag (CU) 208 8,925 8,925 18,797 3 0.9284 0.5186 9,748
5 B 1 1/0 CU 53 Mag (CU) 208 8,925 8,925 18,797 3 0.9284 0.5186 9,748
NOTE: STATED LENGTHS ARE FOR CALCULATION PURPOSES and REPRESENT MINIMUM VALUES. DO NOT USE FOR ESTIMATION TAKE-OFFS.
A
LSW Eng in e e r sR I Z O N A, I N C O R P O R A T DE
www.lswphx.com Project No.FacsimileTelephone
Phoenix, Arizona 850212333 West Northern Avenue 602.249.1320
602.336.3276
© LSW Engineers Arizona, Inc.
SHEET TITLE:
APPROVED BY:
PROJECT NO.:
DATE:
DESIGNED BY:
DRAWN BY:
SHEET NUMBER:
5240 North 16th Street, Suite 101Phoenix, Arizona 85016Telephone: (602) 279-4373Fax: (602) 279-9110
A Limited Liability Company© Copyright 2017
2018-031.000
20186/1
1/2
01
8 8
:24:3
9 A
MC
:\R
evit L
oca
l F
iles\1
803
1-M
EP
17\1
803
1-M
EP
17-b
ram
os.r
vt
E8.1
P2017.114
05-4-2018
RFR/JPS
RFR
AJB
Pin
al C
ount
y - S
an T
anJu
stic
e of
the
Pea
ce C
ourt
s36
55 H
unt H
wy,
Que
en C
reek
, AZ
8514
2
ELECTRICALDIAGRAMS/PANELSCHEDULES
100% CONSTRUCTION DOCUMENTS
N.T.S.1
ONE-LINE DIAGRAMNOTES:
TOTAL EQUIVALENT DEMAND FACTOR: 98.28%
Receptacle - General 15660 81.93% 12830
HVAC 25395 100.00% 25395
Kitchen Equipment 6200 70.00% 4340
Lighting - Exterior 2735 125.00% 3418.8
None 9040 100.00% 9040
Other 90122.6 100.00% 90122.6
Lighting 5392.8 125.00% 6741
LOAD CLASSIFICATION CONNECTED VA DEMAND FACTOR CODE VA
TOTAL CODE LOAD (3Ø kVA): 151.9
TOTAL CODE LOAD (AMPS): 442 A 425 A 404 A
TOTAL CODE LOAD (VA): 52662.8 50680.4 48519.7
TOTAL CONNECTED LOAD (VA): 53586 51569 49370
B 7659 7035 8060
A 6860 6811 7077
M 39069 37725 34234
ØA ØB ØC
LOAD (VA)
Voltage: 208Y/120V, 3Ø, 4W
LOAD CALCULATION: SES
TOTAL EQUIVALENT DEMAND FACTOR: 100.00%
HVAC 25395 100.00% 25395
Other 85632.6 100.00% 85632.6
LOAD CLASSIFICATION: CONN. VA DEMAND FACTOR CODE VA NOTES:
TOTAL CONNECTED 3Ø LOAD (kVA): 111 ...
TOTAL CODE LOAD (AMPS): 330 A 319 A 285 A
TOTAL CODE LOAD (VA): 39068.8 37724.8 34234
TOTAL CONNECTED LOAD (VA): 39069 37725 34234
SPACE -- -- 41 0 0 42 -- -- SPACE
SPACE -- -- 39 0 0 40 -- -- SPACE
SPACE -- -- 37 0 0 38 -- -- SPACE
SPACE -- -- 35 0 0 36 -- -- SPACE
SPACE -- -- 33 0 4493 34
SPARE 1 20 31 0 4493 3230 2 WH-1
EF-3 1 15 29 18 0 30 -- -- SPACE
EF-2 1 15 27 360 528 28 15 1 HWP-1
EF-1 1 15 25 360 1872 26
23 5138 1872 2430 2 OU-1
21 5138 0 22 20 1 SPAREHP-7 3 40
19 5138 0 20 20 1 SPARE
17 3910 4555 18
15 3910 4555 16HP-5 3 30
13 3910 4555 14
30 3 HP-6
11 5138 5138 12
9 5138 5138 10HP-3 3 40
7 5138 5138 8
40 3 HP-4
5 3910 4555 6
3 3910 4555 4HP-1 3 30
1 3910 4555 2
30 3 HP-2
USE AND/OR AREA SERVED P TRIP CKT# A B C CKT# TRIP P USE AND/OR AREA SERVED
ENCLOSURE: NEMA 1 SCCR/AIC RATING: 22,000A
MOUNTING: SURFACE MAINS RATING: 400 A
SUPPLY FROM: SES MAINS TYPE: MLO
VOLTAGE: 208Y/120V, 3Ø, 4W
PANEL: M
TOTAL EQUIVALENT DEMAND FACTOR: 105.44%
Receptacle - General 10260 98.73% 10130
None 5200 100.00% 5200
Other 250 100.00% 250
Lighting - Exterior 2595 125.00% 3243.8
Lighting 2448.7 125.00% 3060.9
LOAD CLASSIFICATION: CONN. VA DEMAND FACTOR CODE VA NOTES:
TOTAL CONNECTED 3Ø LOAD (kVA): 21.9
TOTAL CODE LOAD (AMPS): 60 A 60 A 62 A
TOTAL CODE LOAD (VA): 7233.5 7181.8 7462.2
TOTAL CONNECTED LOAD (VA): 6860 6811 7077
SPACE -- -- 41 0 0 42 -- -- SPACE
SPACE -- -- 39 0 0 40 -- -- SPACE
SPACE -- -- 37 0 0 38 -- -- SPACE
REC - ROOF 1 20 35 720 0 36 -- -- SPACE
LTG - EXTERIOR POLES 1 20 33 1245 0 34 -- -- SPACE
LTG - EXTERIOR POLES 1 20 31 1350 0 32 -- -- SPACE
SPARE 1 20 29 0 0 30 -- -- SPACE
SPARE 1 20 27 0 0 28 -- -- SPACE
REC - AV 124 1 20 25 360 250 26 20 1 IRRIGATION
REC - RR 105, 107 1 20 23 900 1199 24 20 1 LTG - RM 101, 102, 103, 104, 105,...
REC - LOBBY 102 1 20 21 720 1249 22 20 1 LTG - RM 125, 127, 128, 130, 131
X-RAY SECURITY 101 1 20 19 360 0 20 20 1 SPARE
REC - 2ND COURT RM FB 1 20 17 720 720 18 20 1 REC - INTERVIEW ROOM 104, 103
REC - 2ND COURT RM 1 20 15 900 720 16 20 1 REC - INTERVIEW ROOM 109, 110
REC - 2ND COURT RM JUDGE 1 20 13 540 1000 14 20 1 FAX - WORKSTATIONS 125
REC - 2ND COURT RM CLERK 1 20 11 540 1200 12 20 1 PRINTER - WORKSTATIONS 125
SPARE 1 20 9 0 540 10 20 1 REC - WORKSTATIONS 125
REC - WORKSTATIONS 125 1 20 7 540 540 8 20 1 REC - WORKSTATIONS 125
DATA RACK - IT 128 1 20 5 360 720 6 20 1 REC - RECEPTION 131
REC - PRINT/COPY 127 1 20 3 900 540 4 20 1 REC - WORKSTATIONS 125
PRINTER - PRINT/COPY 127 1 20 1 1200 720 2 20 1 REC - CHIEF CLERK 126
USE AND/OR AREA SERVED P TRIP CKT# A B C CKT# TRIP P USE AND/OR AREA SERVED
ENCLOSURE: NEMA 1 SCCR/AIC RATING: 22,000
MOUNTING: SURFACE MAINS RATING: 125 A
SUPPLY FROM: SES MAINS TYPE: MLO
VOLTAGE: 208Y/120V, 3Ø, 4W
PANEL: A
TOTAL EQUIVALENT DEMAND FACTOR: 95.20%
Receptacle - General 5400 100.00% 5400
None 3840 100.00% 3840
Other 4240 100.00% 4240
Lighting - Exterior 140 125.00% 175
Lighting 2944.3 125.00% 3680.4
Kitchen Equipment 6200 70.00% 4340
LOAD CLASSIFICATION: CONN. VA DEMAND FACTOR CODE VA NOTES:
TOTAL CONNECTED 3Ø LOAD (kVA): 21.7
TOTAL CODE LOAD (AMPS): 62 A 56 A 65 A
TOTAL CODE LOAD (VA): 7291.3 6697.3 7673.4
TOTAL CONNECTED LOAD (VA): 7659 7035 8060
SPACE -- -- 41 0 0 42 -- -- SPACE
SPACE -- -- 39 0 0 40 -- -- SPACE
SPACE -- -- 37 0 0 38 -- -- SPACE
SPACE -- -- 35 0 0 36 -- -- SPACE
SPACE -- -- 33 0 0 34 -- -- SPACE
SPACE -- -- 31 0 0 32 -- -- SPACE
SPACE -- -- 29 0 0 30 -- -- SPACE
GATE BARRIER 2 1 20 27 1920 0 28 -- -- SPACE
GATE BARRIER 1 1 20 25 1920 0 26 -- -- SPACE
REC - COURT RM 122 SEATING 1 20 23 1560 140 24 20 1 LTG - BOLLARDS
REC - COURT RM 111 JURY 1 20 21 360 639 22 20 1 LTG - EXTERIOR
REC - COURT RM 111... 1 20 19 720 900 20 20 1 REC - EXTERIOR
REC - COURT RM 111... 1 20 17 720 720 18 20 1 REC - JURY
REC - COURT RM 111 CLERK 1 20 15 540 800 16 20 1 MINI FRIDGE - JURY
REC - COURT RM 111 JUDGE 1 20 13 720 1500 14 20 1 COFFEE MAKER - JURY RM
PRINTER - COURT RM 111 1 20 11 1200 1500 12 20 1 COFFEE MAKER - BREAK RM
SPARE 1 20 9 0 900 10 20 1 REFRIDGERATOR - BREAK RM
TIME CLOCK FOR EXTERIOR... 1 20 7 0 360 8 20 1 REC - BREAK ROOM 123
REC - JUDGE'S OFFICE 1 20 5 720 1500 6 20 1 REC - BREAK ROOM 123
REC - RR 117, 118, HALL 115 1 20 3 540 1340 4 20 1 LTG - RM 120, 119, 118, 117, 116,...
REC - FILE STORAGE 1 20 1 180 1365 2 20 1 LTG - 115, 121, 123, 126, 136
USE AND/OR AREA SERVED P TRIP CKT# A B C CKT# TRIP P USE AND/OR AREA SERVED
ENCLOSURE: NEMA 1 SCCR/AIC RATING: 22,000A
MOUNTING: SURFACE MAINS RATING: 125 A
SUPPLY FROM: SES MAINS TYPE: MLO
VOLTAGE: 208Y/120V, 3Ø, 4W
PANEL: B
NO. REVISION DATE
1 UTILITYCOORDINATION
06/11/2018
1
1
1
06.11
.18
43861
ADAM J.BAGBY
CE
R
T I F IC AT E
NO
.
Re
gis
tere
dP
rofessional Engineer
(Ele
ct ri c
al)
EXPIRES: 03/31/21
Recommended