design and calculation of grit removal in waste water treatment
Citation preview
Q 42076.8 m3/hariWaktu operasi 24 jam/hari
1753.2 m3/jam29.22 m3/min0.487 m3/s
Type Horisontal flowdibuat 1 grit (channel) dengan proportional weir
Detention time 60 s1 min
Kecepatan horisontal (Vh) 0.3 m/sDiameter partikel minimal yg diendapkan 0.2 mm
65 mesh
Suhuv = 0.00008774 cm/skecepatan pengendapan 1.15 m/min
0.01917 m/sSg grit 2.65k 0.05f 0.02
Perhitungan
Q channel 0.487
1.62
25.41 1. DIMENSIKedalaman Air, h 1.15 m Lebar Grit Chamber 1.41 mPanjang Grit Chamber 18.00 mR 0.437
1,495 Check OKE
8.05 m/sCheck OKE
Direncanakan
Debit buangan 0.487
oC
m3/s
Luas Penampang (ACross) m2
Luas Permukaan (ASurface) m2
NRe =
2. KECEPATAN SCOURING, VSC
VSC =
m3/s
42,077
Kadar (kandungan pasir) 30
per 1,000,000 Pengurasan tiap 3 hariBentuk Grit Storage Trapezium
Perhitungan
Volume Pasir dalam 1 hari 1
Volume Pengurasan 4 Dimensi Grit Storage
a Panjang Grit Chamber 18.00 mb Lebar Grit Chamber 1.41 mc panjang dasar trapesium 15.35 md lebar dasar trapesium 0.5 m
Luas Permukaan 25.4
Luas Dasar 7.7
Volume Grit Storage 3.79 tinggi trapesium 0.24 m
3.PROPORTIONAL WEIRDirencanakan
Q, debit 0.487 17.198 ft3/s
a 0.1 m 0.33 fty 0.2 m 0.66 fth = tinggi muka air di grit chamber 1.15 m
3.77292 ft
diperoleh nilai b, = 1.65 ft 0.503 m
Perbandingan, y/a = 2Dari tabel diperoleh, nilai x/b = 0.392shg x 0.65 ft
Marsono, "Hidrolika Teknik Penyehatan", Hal : II-53)
m3/hari
m3
m3 Air buangan
m3
m3
m2
m2
m3
m3/s
Dimensi Proportional weir :a 0.328 ftb 1.649 ftx 0.646 fty 0.656 ft
grit (channel) dengan proportional weir
18.15
18.00 ma
b 1.41
t
dc 0.5
15.35