View
219
Download
0
Category
Preview:
Citation preview
8/2/2019 HOMER Training - Participant Quick Step Guides
1/21
cpg 20110318 1
HOMER Online Training Course
Participant Quick Steps Lesson 1: Simulation
LESSON 1EXERCISE 1:SIMULATE A DIESEL-ONLY SYSTEM
ADD LOAD AND GENERATOR TO SCHEMATIC
1. Start HOMER and create a new file. Save it as lesson-1-exercise-1.hmr
2. Click Add/Remove
3. Check Primary Load 1 and Generator 1
4. Click OK
LOAD
1. Click Primary Load 1
2. For Label, type Small Load
8/2/2019 HOMER Training - Participant Quick Step Guides
2/21
cpg 20110318 2
3. Show Load type options
4. Type first few values in table, then cut and paste from load profile.txt.
5. Show annual data table
6. Click Plot
7. Show hourly data
8/2/2019 HOMER Training - Participant Quick Step Guides
3/21
cpg 20110318 3
8. Show Month and Day type lists
9. Close DView and Load Inputs window.
10. Save file
GENERATOR COMPONENT
1. Enter data for the generator component:
Costs: 14, 13000, 13000, 0.5Sizes: 14 kWDescription: Generator; Abbreviation: Gen, Lifetime: 20000
2. Show AC and DC options
3. Click Fuel tab
4. Click OK
FUEL COST
1. Click Diesel resource button
8/2/2019 HOMER Training - Participant Quick Step Guides
4/21
cpg 20110318 4
2. Specify the diesel fuel cost: 0.60
3. Click OK
SPECIFYECONOMICS INPUTS
1. Show Other inputs
2. Click Economics
3. Change interest rate to 8
CALCULATE
1. Click Calculate
2. Review results
3. Click Small Load. Compare load profile to generator nominal power of 14 kW.
8/2/2019 HOMER Training - Participant Quick Step Guides
5/21
cpg 20110318 5
LESSON 1EXERCISE 2:SIMULATE DIESEL SYSTEMS WITH AND WITHOUT
STORAGE1. Start HOMER and open the file lesson-1-exercise-1.hmr. Save the file as lesson-1-exercise-2.hmr.
2. Click Add/Remove
3. Add a battery to the schematic.
4. Click OK.
8/2/2019 HOMER Training - Participant Quick Step Guides
6/21
cpg 20110318 6
5. Click Add/Remove
6. Check Converter
7. Choose Trojan L16P
9. Enter data for the battery component:Costs: 1, 220, 220, 4
Batteries per string: 8Sizes: 0, 1.
10. Click Converter
8/2/2019 HOMER Training - Participant Quick Step Guides
7/21
cpg 20110318 7
11. Enter data for the converter component:
Costs: 1, 800, 800, 0
Sizes: 0, 12
CALCULATE AND REVIEW RESULTS
1. Click Calculate
2. Double-click generator-only system
3. Click Gen tab
8/2/2019 HOMER Training - Participant Quick Step Guides
8/21
cpg 20110318 8
4. Double-click generator-battery system.
5. Click Gen tab
8/2/2019 HOMER Training - Participant Quick Step Guides
9/21
cpg20110318 1
HOMER Online Training Course
Participant Quick Steps Lesson 2: Optimization
LESSON 2EXERCISE 1:OPTIMIZE THE GENERATOR-BATTERY SYSTEM
1. Open lesson-1-exercise-2.hmr and save it as lesson-2-exercise-1.hmr
2. Expand the search space:Strings: add 2, 3Converters: add 4, 8
3. Run the optimization and display overall results.
8/2/2019 HOMER Training - Participant Quick Step Guides
10/21
cpg20110318 2
4. Show categorized results.
5. Note search space insufficient message
6. Show winning sizes
7. Adjust the search space: Add 4, 5, 6 strings
8/2/2019 HOMER Training - Participant Quick Step Guides
11/21
cpg20110318 3
8. Run the optimization and display overall results
LESSON 2EXERCISE 2:ADD SOLAR PANELS1. Add PV to the schematic
8/2/2019 HOMER Training - Participant Quick Step Guides
12/21
cpg20110318 4
2. Specify PV costs
7500, 7000,
3. Specify sizes to consider0, 4, 8, 12
4. Enter solar resource data36 N, 87 W, GMT -6
5. Categorized results
8/2/2019 HOMER Training - Participant Quick Step Guides
13/21
cpg20110318 5
6. Simulation results for diesel-battery
8. Simulation results for diesel-pv-battery
8. Refine search space to add more sizes of PV array:2, 3, 5 kW
8/2/2019 HOMER Training - Participant Quick Step Guides
14/21
cpg20110318 6
9. Calculate and note renewable fraction of optimal system
LESSON 2EXERCISE 3:ADD WIND TURBINES1. Add a wind turbine to the schematic
2. Choose Generic 3 kW
3. Costs: 1, 9000, 8000, 150
4. Sizes to consider 0, 1, 2, 3, 4
5. Hub height 20 m
8/2/2019 HOMER Training - Participant Quick Step Guides
15/21
cpg20110318 7
6. Note input warning
7. Enter wind resource data: 6 m/s annual averaage
8. Show hourly data
8/2/2019 HOMER Training - Participant Quick Step Guides
16/21
cpg20110318 8
9. Calculate
8/2/2019 HOMER Training - Participant Quick Step Guides
17/21
cpg20110318 1
HOMER Online Training CourseParticipant Quick Steps Lesson 3: Optimization
LESSON 3EXERCISE 1:ONE-DIMENSIONAL SENSITIVTY ANALYSIS ON WIND
SPEED
1. Open lesson-2-exercise-3.hmr and save it as lesson-3-exercise-1.hmr
2. Wind Resource Inputs
3. Scaled annual average: 4 m/s
4. Click Plot
8/2/2019 HOMER Training - Participant Quick Step Guides
18/21
cpg20110318 2
5. Wind Scaled Annual Average Sensitivity:4, 5, 6, 7
6. Calculate
7. Show Sensitivity results
8. Double-click 7 m/s system
8/2/2019 HOMER Training - Participant Quick Step Guides
19/21
cpg20110318 3
LESSON 3EXERCISE 2:TWO-DIMENSIONAL SENSITIVITY ANALYSIS ON WIND
SPEED AND FUEL PRICE1. Open lesson-2-exercise-3.hmr and save it as lesson-3-exercise-1.hmr
2. Add fuel price sensitivity:0.8, 1.0
3. Calculate4. Sensitivity table
5. OST Graph
8/2/2019 HOMER Training - Participant Quick Step Guides
20/21
cpg20110318 4
6. Superimpose Generik 3 kW
7. Click sensitivities button
8/2/2019 HOMER Training - Participant Quick Step Guides
21/21
cpg20110318 5
8. Calculate