Standard Hospital WardIntensive Care UnitCritical Care Unit
Nursing/HomeCare
Best solution for specialpurposes:
Mattresses — what to be aware of?
How to choose the right mattress?
Bottoming-out — high risk of pressure ulcerMattress deflation — compressor not connected correctly, correct risk assessment of the patientIncorrectly selected pressure Lifting the back section without pressure adjustment
Height between the mattress and the side rail to comply with the norm.Regular mattress cleaningChose mattress for prevention or treatment of pressure ulcers
Burn patients — Low air-loss system – ProphyCair
Patients in prone position — Virtuoso (with prone-zoner option)
Bariatric patients — exceptional weight limit — ProphyCair
Besides the high-quality of mattress the patient should get always the solution which always conform to patient́ s needs. Also, the caregiver in general should be aware of situations which brings the patient in potential risks. Linet́ s mattresses includes features which help to eliminate this risk.
Passive mattressesFoam mattresses constructed from Polyurethane (PU) foam or PU and viscoelastic foamDiverse sections on both upper and lower layerSingle foam and foam combinationsLarge weight range from paediatric to bariatricWide range of sizes to meet needs of all bed-frames
Reactive mattresses (Hybrid Foam)Constructed of air foam cells with a top layer of viscoelastic foam.Increased patient comfort and more effective preventionCan be used in combination with a compressor to give alternating pressure and MCMManagement of moisture between skin and mattress (when compressor attached MCM)
Active mattressesIncludes mattresses with cells, the mattress is constantly connected to the compressorDifferent cell technologies Different types of therapiesConstant low pressureTherapy based on distributing pressure across the patient's entire bodyAppropriate low pressure is set and maintainedModerLow-air-lossConstant air loss — microclimate management — dissipation of moisture between skin and mattressAt 100% relative humidity, the skin is 25 times weaker than at 50% humidity Alternating therapiesA critical aspect of therapy is the reduction of pressure on the patient's body to allow oxygen and nutrients to circulate freely and accelerate healing Zero pressure is achieved by alternating pressure within the 3-cell system of the mattress (3-cell and 2-cell system)
ALTERNATIONThe alternation regularly release the pressure under a patient by changing the pressure in different areas of mattress. This brings relaxation for skin in areas where is mattress deflated. Moreover, with 3-cell technology the alternation provides zero pressure, which fully eliminates the action of pressure on high-risk areas of the body.
CONSTANT LOW PRESSUREThe system automatically maintains the selected pressure value regardless of changes in the patient's weight distribution or position. This constantly optimizes the pressure acting on the skin.
PASSIVE SYSTEMA comprehensive range of static mattresses from single block Polyurethane foam to Viscoelastic 7 zoned mattresses, the CliniCare 30 having CLIMA technology to help manage the temperature at the patient skin mattress interface.
Virtuoso(ALTERNATING+CLP SYSTEM)
Highest clinical effectEnhanced care for proned patientsBattery Back-up24 hour care | Easy hygiene
Symbioso 200(CLP SYSTEM)
Semi-automatic systemEasily controllable from bed displayImproved prevention with MCM | Easy hygiene
Primacare(PASSIVE MATTRESS)
Weight limit 200 kgProfiling of foam on top
EffectaCare(PASSIVE MATTRESS)
Combination of standard PU foam with 7-zoned visco layer on topSideformersWeight limit 230 kg
Precioso(ALTERNATING+CLP SYSTEM)
Highest clinical effectReplacement & overlay version24 hour careEasy hygiene
ProphyCair(CLP LOW AIR-LOSS SYSTEM)
Improved prevention with low air-loss featureExceptional weight capacityOptional dimensions to fits bariatric beds
CliniCare 100 HF(REACTIVE SYSTEM)
High comfort for patientsProvides preventive effect without pumpProvides enhanced clinical effect in connection with pump (MCM, APT)
Air2Care(ALTERNATING AND CLP SYSTEM)
Effective & comfortableReplacement & overlay version24 hour careEasy hygiene
Complete immobility,unconsciousness
Partially mobilepatients at high risk of decubitus
Partially mobile patients after surgery
Mobile patients at risk of decubitus
Mobile patients at low risk ofdecubitus
I + I I
I I I
I V
Risk of pressure
ulcer development
EffectaCare
PrimaCare
CliniCare
ProphyCairBurn patients Low air-loss system
Symbioso 200
Air2Care
CliniCare 100 HF(reactive system)
Grade of existing
pressure ulcer
VirtuosoPatients in prone position
Precioso
Recommended