Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK00
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
GENERAL
DRAWING LIST + LOCATION PLANFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
HUTT STREET
SOU
TH T
ERR
ACE
RAMP 1:14
GILLES STR
EET
VERANDAH OVERVERANDAH OVER VERANDAH OVER
LOCAL HERITAGE PLACE (BUILT FORM ALIGNMENT)PROPOSED ENTRY ALIGNMENT (BOUNDARY LINE)
EXTENT OF NEIGHBOURING VERANDAHS
254
NEIGHBOURINGPROPERTY
HUTT STREET
PROPOSEDADDITION
VINCENT PLACE
258 260
CT
AB AB
262
VERANDAH OVERVERANDAH OVER
(EXTENT OF LOCAL HERITAGE PLACES)
CT
NEIGHBOURINGPROPERTY
OVERALL SITE PLAN1:500
SITE ANALYSIS1:500
ARCHITECTURAL PREPARED BY FLIGHTPATH ARCHITECTS
3582
Hutt Street Centre Redevelopment
LOCATION OF WORKS
SUBJECT LAND
CT (CERTIFICATEOF TITLE)
AB (ALLOTMENTBOUNDARY)
EASEMENT
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK01
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
DEMOLITION PLANFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
EXISTING LANDSCAPING TO BEDEMOLISHED IN PREPARATIONFOR NEW
EXISTING LANDSCAPING TO BEDEMOLISHED IN PREPARATIONFOR NEW
r'AC
e'DB
r'AC
e'DB
r'AC
r'AC
e'DBr'AC
r'HWSr'HWS
r'AC r'AC r'AC
r'RWT
e'DB
NEIGHBOURINGSHED
VINCENT PLACE
ADJOININGPROPERTIES
NEIGHBOURINGPROPERTY
e'dp.
OPEN
LANE
WAY
ADJOININGPROPERTIES
e'dp.
VERANDAH OVER
d'FENCE
d'FE
NCE
e' NEIGHBOURS FENCE
e' F
ENCE
d'col.
e' EASEMENT
d'col.
d'col.
d'col.
d'col.
d'col.
d'col.
d'dp.d'dp.
d'bric
k.
DEMOLISH ALL EXISTINGFLOOR FINISHES ANDPREPARE SUBSTRATE
FOR NEW
DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
TACTILE GROUND SURFACEINDICATOR TO AS1428
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
STEP RAMP
HAND RAIL
STORM WATER ACCESS HATCH
DEMOLITION LEGEND
GENERAL NOTES:1. PROTECT ITEMS AND FINISHES TO REMAINAGAINST DAMAGE DURING CONSTRUCTION.
2. ALLOW FOR TEMPORARY SUPPORTSREQUIRED TO SUPPORT EXISTING REMAININGCONSTRUCTION.
EXISTING WALL TO REMAIN
EXISTING FLOORING & ASSOCIATEDWORKS TO BE REMOVED.
EXISTING ELEMENT TO BEREMOVED
PROVISION OF SERVICES ANDPROGRAMS
col.
TGSI
AC
DB
RWTHWS
SRHR
SWA
MU
DEMOLITION PLAN1:200
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK02
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
ROOF PLAN - DEMOLITIONFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
TACTILE GROUND SURFACEINDICATOR TO AS1428
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
STEP RAMP
HAND RAIL
STORM WATER ACCESS HATCH
DEMOLITION LEGEND
GENERAL NOTES:1. PROTECT ITEMS AND FINISHES TO REMAINAGAINST DAMAGE DURING CONSTRUCTION.
2. ALLOW FOR TEMPORARY SUPPORTSREQUIRED TO SUPPORT EXISTING REMAININGCONSTRUCTION.
EXISTING WALL TO REMAIN
EXISTING FLOORING & ASSOCIATEDWORKS TO BE REMOVED.
EXISTING ELEMENT TO BEREMOVED
PROVISION OF SERVICES ANDPROGRAMS
col.
TGSI
AC
DB
RWTHWS
SRHR
SWA
MU
ROOF PLAN LEGEND
ROOF PITCHROOF MATERIAL
MAXLINE ROOF SHEETCOLORBOND 'TBC'
CORRUGATED ROOF SHEETCOLORBOND 'TBC'
CORRUGATED ROOF SHEETCOLOUR: CLEAR
FALL 0°RS01
RS01
RS02
RS03
PORTION OF EXISTING ROOF TO BEDEMOLISHED TO SUIT NEW WORKS.NEW FASCIA, GUTTER ANDFLASHINGS WHERE REMOVED
PORTION OF EXISTING ROOF TO BEDEMOLISHED TO SUIT NEW WORKS.NEW FASCIA, GUTTER ANDFLASHINGS WHERE REMOVED
PORTION OF EXISTING ROOF TO BEDEMOLISHED TO SUIT NEW WORKS. NEWFASCIA, GUTTER AND FLASHINGS WHEREREMOVED. DOWNPIPES TO BE RELOCATED
PORTION OF EXISTING ROOF TO BEDEMOLISHED TO SUIT NEW WORKS.NEW FASCIA, GUTTER ANDFLASHINGS WHERE REMOVED
REMOVE EXISTINGGUTTERS
d'CA
NOPY
d'SHED
d'CANOPY
e' ROOF
RETAI
NED
BOUNDARY
BOUN
DARY
d'SH
ED
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
d'CANOPY
d'dp. d'dp.
e'dp. e'r
h.
r'dp.
r'dp.r'dp.
e'dp.
ROOF PLAN - DEMOLITION1:200
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK03
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
PROPOSED GROUND FLOOR PLANFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
TACTILE GROUND SURFACEINDICATOR TO AS1428
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
STEP RAMP
HAND RAIL
STORM WATER ACCESS HATCH
PROVISION OF SERVICES ANDPROGRAMS
col.
TGSI
AC
DB
RWTHWS
SRHR
SWA
MU
CONSERVATION AND REPAIRS TO FACADES OF LOCAL HERITAGE PLACES
6,000
1SK06
3SK08
2SK
08
REFER LANDSCAPINGFOR WORKS
REFER LANDSCAPINGFOR WORKS
BRICK TO MATCHEXISTING FOOTPATH
e'DB
e'DB
e'DB
e'DB
NEIGHBOURINGSHED
VINCENT PLACE
ADJOININGPROPERTIES
NEIGHBOURINGPROPERTY
RAMP 1:14
GL: 0.00RL: 48.20
GL: -380RL: 47.82
GL: -190RL: 48.01
GL: 0.00RL: 48.20
GL: 0.00RL: 48.20
GL: +270RL: 48.47
GL: +135RL: 48.33
SR
GL:0.00RL: 48.20
GL: +135RL: 48.33
GL: -200RL: 48.0
GL: -10RL: 48.18
SR
SR
e'dp.
BOARDROOM/REFLECTION/GATHERING
HR
HR
HR
SWA
FOOD STORE
LDRY
STAFFKITCHEN
STAFFCOURTYARD
BALCONY OVER
CANO
PY O
VER
LANE
WAY
ADJOININGPROPERTIES
e'dp.
VERANDAH OVER
G-01G
-02 FALL
GL: +270RL: 48.47
100mmSTEPSR
SR
GL: 0.00RL: 48.20
STEP
STEP
ACCESS WC
WOMENMEN
MEALS
KITCHEN
MU
MU
LAUNDRY
OUTDOORKITCHEN
KIT
CH
ENET
TE
MU
ART ROOM/RECREATION
OPEN PLAN OFFICE
MU
GRASS/PLAY
MU/LOUNGE
MU
ENTRY
MU
MU
STORAGE
STORAGE
STORAGE
CO
OL
RO
OM
COOL ROOM
COOL ROOM
COMMS
OFFICE/MEETING
RECEPTION
STORAGE
OFFICE/MEETING
OFFICE/MEETING
OFFICE/MEETING
OFFICE/MEETING
COURTYARD
OPEN PLAN OFFICE
LOCKERS/STORAGE
OFFICE/MEETING
MU
STORE
BIN STORE/ SHED
BIN COLLECTION
SKYLIGHT OVER
SKYLIGHT OVER
TGSITG
SITG
SI
e' NEIGHBOURS FENCE
e' F
ENCE
n' FENCE
n' TREE(REFER
LANDSCAPING)
e' EASEMENT
n'col.
n'col.
n'col.
n'col.
n'col.
n'col.
n'col.
n'col.
n'col.
n'col.
n'col.
n'dp.
n'dp.
CANOPY O
VER
CANOPY OVER
e'col. e'c
ol.
e'col.
e'col.
GROUND FLOOR PLAN1:200
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK04
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
FIRST FLOOR PLANFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
TACTILE GROUND SURFACEINDICATOR TO AS1428
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
STEP RAMP
HAND RAIL
STORM WATER ACCESS HATCH
PROVISION OF SERVICES ANDPROGRAMS
col.
TGSI
AC
DB
RWTHWS
SRHR
SWA
MU
NO WORKS TOFIRST FLOOR
MEETING/OFFICES
BALCONY
MEETING/OFFICES
MEETING/OFFICES
FIRST FLOOR PLAN1:200
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK05
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
PROPOSED ROOF PLANFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
dp.
CONNECT NEWDOWNPIPES TO EXISTINGSTORMWATER SYSTEM
BOX GUTTER BELOW
NEW DOWNPIPECONNECTED TO EXISTINGSTORMWATER SYSTEM
NEW DOWNPIPECONNECTED TO EXISTINGSTORMWATER SYSTEM
e' ROOF TO BE
REPAINTED [RP1]
e' ROOF
RETAI
NED
BOUNDARY
BOUN
DARY
e' ROOF NOWORKS
BOUNDARY GUTTER
GUTTER
BOUNDARY GUTTER
GUT
TER
n'GUTTER
n'G
UTTE
R
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
e' ROOF NOWORKS
FALL 1°RS02
FALL
40°
RS02
FALL
40°
RS02
FALL
40°
RS03
FALL
40°
RS03
FALL 40°RS01
FALL 40°RS01
FALL 2°RS03
MAT
CHEX
ISTI
NG F
ALL
RS02
FALL
2°
RS02
INDICATIVE LOCATION OFSERVICES PLANT
dp.
dp.
SL
SL
SL
PLAN
T
n'dp.
e'dp. e'r
h.
r'dp.
r'dp.r'dp.
e'dp.
STEEL CLADDING (COLOUR TBC) DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
MAXLINE ROOF SHEETCOLORBOND 'MONUMENT'
ROOF PITCHROOF MATERIAL
TACTILE GROUND SURFACEINDICATOR TO AS1428
ROOF DECKINGCOLORBOND 'WINDSPRAY'
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'
AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
CORRUGATED ROOF SHEETCOLOUR: CLEAR
MAXLINE CLADDINGCOLORBOND 'MONUMENT'
GLAZING
FENCE BLADESREFER LANDSCAPING
SW STONE WALLSANDSTONE
F-01 CORRUGATED FENCECOLORBOND 'WINDSPRAY'
FASCIACOLORBOND 'MONUMENT'
col.
RS01
FALL 0°RS01
TGSI
RS02
RS03
AC
DB
RWTHWS
SC01
GL
FB
F
ROOF PLAN - PROPOSED1:200
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK06
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
ELEVATIONSFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
-102 FOOTPATH ±0 FFL+270 HERITAGE BUILDING FFL
+2,100 FENCE+2,830 INTERNAL CEILING+3,300 CANOPY
+4,970 NEW ROOF
+6,300 EXISTING ROOF
+1,680 FENCE
(LHP)CONSERVATION + REPAIRS TO FACADE
PROPOSEDENTRYNEW CANOPY
STEEL CLADDING (COLOUR TBC) DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
MAXLINE ROOF SHEETCOLORBOND 'MONUMENT'
ROOF PITCHROOF MATERIAL
TACTILE GROUND SURFACEINDICATOR TO AS1428
ROOF DECKINGCOLORBOND 'WINDSPRAY'
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'
AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
CORRUGATED ROOF SHEETCOLOUR: CLEAR
MAXLINE CLADDINGCOLORBOND 'MONUMENT'
GLAZING
FENCE BLADESREFER LANDSCAPING
SW STONE WALLSANDSTONE
F-01 CORRUGATED FENCECOLORBOND 'WINDSPRAY'
FASCIACOLORBOND 'MONUMENT'
col.
RS01
FALL 0°RS01
TGSI
RS02
RS03
AC
DB
RWTHWS
SC01
GL
FB
F
±0 FFL+270 LHP FFL
+3,300 UNDERSIDE CANOPY
+4,970 NEW RIDGE LINE
+6,300 EXISTING RIDGE LINE
-420 FOOTPATH
±0
+1,680 FENCE HEIGHT
+2,100 FENCE HEIGHT
2,10
0
PROPOSEDENTRYNEW CANOPY
FF
GL GL GL
GL
FB FB
SW SW
FB
RS03
HUTT ST STREETSCAPE1:200
WEST ELEVATION1:100
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK07
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
ELEVATIONSFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
RP1
RP2
RP2 RP2 RP2
EX
RP1 RP1 RP1
EX EX
RP3
REPAINTING LEGEND
REPAINTED ROOF SHEET:COLORBOND: WINDSPRAY
ACCESSORIES (GUTTERS,DOWNPIPES, FASCIAS):COLORBOND: MONUMENT
REPAINTED RENDERTO MATCH COLORBOND'SURFMIST'
NEW DOORCOLORBOND: MONUMENT
EXISTING, NO REPAINTING
RP1
RP2
RP3
EX
REPAINTED TO MATCH EXISTING (FOLLOWING CONSERVATION WORKS)
EXISTING BUILDING - REPAINTING WORKS (1:100)
EXISTING BUILDING - REPAINTING WORKS (1:200)
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK08
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
ELEVATIONSFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
STEEL CLADDING (COLOUR TBC) DOWNPIPE
LEGEND
dp.COLUMN, REFER ENGINEERING.
MAXLINE ROOF SHEETCOLORBOND 'MONUMENT'
ROOF PITCHROOF MATERIAL
TACTILE GROUND SURFACEINDICATOR TO AS1428
ROOF DECKINGCOLORBOND 'WINDSPRAY'
EXISTINGe'DEMOLISHd'
NEWn'REMOVEr'
AIR CONDITIONING SYSTEM
DISTRIBUTION BOARD
RAINWATER TANK
HOT WATER SERVICE
CORRUGATED ROOF SHEETCOLOUR: CLEAR
MAXLINE CLADDINGCOLORBOND 'MONUMENT'
GLAZING
FENCE BLADESREFER LANDSCAPING
SW STONE WALLSANDSTONE
F-01 CORRUGATED FENCECOLORBOND 'WINDSPRAY'
FASCIACOLORBOND 'MONUMENT'
col.
RS01
FALL 0°RS01
TGSI
RS02
RS03
AC
DB
RWTHWS
SC01
GL
FB
F
-420 FOOTPATH
±0 EXISTING FFL
+2,911
STAINED GLASSWINDOW TO NORTHAND SOUTHELEVATION
STONE WALL
STEEL FENCE
EXISTINGBUILDING
RS01
SC01
±0 FFL
+1,800 EXISTING FENCE
+2,810 NEW WALL
+3,600 NEIGHBOURINGWALL
+4,200 NEW ROOF
OUTLINE OF EXISTINGNEIGHBOURING FENCE(TO BE RETAINED)
OUTLINE OF EXISTINGSHED (OUTSIDE SITEBOUNDARY)
OUTLINE OF BUILDINGTO REAR OF HUTT STCENTRE
NEW ROOFSTRUCTURE
BUILDING BEYOND
NEW PERFORATEDROLLER DOOR FORVENTILATION
NEIGHBOURINGBUILDING
SCREENING OF PLANTEQUIPMENT AS REQUIRED
RS02 RS03
NEW FENCE[F-01]
NEW BRICK WALL[BW01]
RS03
EXISTING WALL
EXISTING WALL
HWS
ENTRY - NORTH ELEVATION1:100
EAST FENCE ELEVATION1:100
E-07
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK09
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
3D VIEWSFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK10
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
3D VIEWSFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
Issue ID Issue Name Date
01 PLANNING 5/11/19Plot Date:
Drawn | Checked Hutt Street Centre Redevelopment258 Hutt Street Adelaide SA 5000PROJECT NAME :
DRAWING TITLE :
Site:
Project NO.
DRAWING NO.
SK11
REVISION NO.
01PRELIMINARY
5/11/193582
Project Status
ZG | SN
RCP + Hutt Street CentreClient
SKETCH PLANS
3D VIEWSFlightpath Architects Pty Ltd
ABN 16 085 522 014101 Hindley Street Adelaide SA 5000
T +61 8 8211 6355www.flightpatharchitects.com.au
NOTEThe Builder shall check all dimensions and levels on site prior to construction.Notify any errors, discrepancies or omissions to the architect. Refer to writtendimensions only. Do not scale drawings. Drawings shall not be used forconstruction purposes until issued for construction. This drawing reflects a designby Flightpath Architects and is to be used only for work when authorised in writingby Flightpath Architects.
All boundaries and contours are subject to survey drawing W-01. All levels toAustralian Height Data. It is the contractors responsibility to confirm allmeasurements on site and locations of any services prior to work on site.
All documents here within are subject to Australian Copyright Laws.
Recommended