View
226
Download
1
Category
Preview:
Citation preview
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Superior Finish
Exposed Ties
Master Wall Adhesive
Internal Ties
¾” (19 mm) min. Master Wall Insulation Board
Master Wall Base Coat & Mesh
Superior Finish
Master Wall Base Coat & Mesh
ICF-01 Cross-Section
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Superior Finish
Master Wall Mesh
Master Wall Base Coat Primecoat (optional)
ICF-02 Cross-Section Isometric
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Window Head Flashing with turned up ends as required by window manufacturer or building code (by others)
Sealant (by others)
Master Wall Adhesive
Size sealant joint for Anticipated Movement - typically 1/2” (13 mm)
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-03 Clad Window Head
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Slope 1:2 min.
Window Head Flashing with turned up ends as required by window manufacturer or building code (by others)
Sealant (by others)
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-04 Clad Window Head with Trim
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Sealant (by others)
Sealant sized for anticipated movement, 1/2” (13 mm) min. (by others)
Window Head Flashing with turned up ends as required by window manufacturer or building code (by others)
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-05 Wood Window Head (Door Similar)
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Slope 1:2 min.
Window Head Flashing with turned up ends as required by window manufacturer or building code (by others)
Sealant (by others)
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-06 Wood Window Head with Trim
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Sealant sized for anticipated movement, 1/2” (13 mm) min. (by others)
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-07 Clad Window Jamb
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Sealant sized for anticipated movement, 1/2” (13 mm) min. (by others)
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-08 Clad Window Jamb with Trim
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Sealant sized for anticipated movement, 1/2” (13 mm) min. (by others)
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-09 Clad Window Sill
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Sealant sized for anticipated movement, 1/2” (13 mm) min. (by others)
Master Wall Adhesive
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Slope 1:2 min. Adhesive
Wrap Mesh 2-1/2” (64 mm) onto substrate
ICF-10 Clad Window Sill with Trim
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Aggre-flex
Insulation
Master Wall
Base Coat &
Mesh
Superior Finish
ICF Substrate
Slope 1”2 min.
½” Sealant Joint
Window (Self-Flashing shown, coordinate window flashing to meet manufacturer’s requirements)
Rollershield &
Rollershield
Flashing Tape
Master Wall Adhesive
– vertically notched
ICF-23 Flashed Window Head with Trim
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Aggre-flex
Insulation
Master Wall
Base Coat &
Mesh
Superior Finish
ICF Substrate
½” Sealant Joint
Window (Self-Flashing shown, coordinate window flashing to meet manufacturer’s requirements)
Rollershield &
Rollershield
Flashing Tape
Master Wall Adhesive
– vertically notched
ICF-24 Flashed Window Sill with Trim
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Downspout (by others)
Fastener and Strap set in Sealant – Snug Tighten Only (by others)
Superior Finish Master Wall B ase Coat & Mesh
ICF-11 Typical Downspout Attachment
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Roofing (by others)
Soffit (by others)
ICF (by others)
Fascia (by others)
Superior Finish Master Wall Base Coat & Mesh
ICF-12 Typical ICF to Soffit Transition
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Weather Resistive Barrier (by others)
Superior Finish
Master Wall Base Coat & Mesh
Master Wall Insulation Board
Drainage Track
Superior Finish
Master Wall Base Coat & Mesh
ICF-13 Typical Drainage EIFS to ICF Transition
ICF (by others)
Framing & Approved Substrate (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Superior Finish
Master Wall Base Coat & Mesh
Sealant (by others)
ICF-14 Pipe Penetration Detail
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
Light Fixture Set in Sealant (by others) Insulation Board
Master Wall Base Coat & Mesh
Superior Finish
ICF-15 Typical Light Fixture
ICF (by others)
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Master Wall Base Coat & Mesh
Superior Finish
Dryer Vent – Set vent and fasteners in sealant (by others)
ICF-16 Dryer Vent Detail
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Note: Keep siding at least 6” (152 mm) above grade unless local building codes allow closer applications of the base coat, mesh and finish
Master Wall Base Coat & Mesh
Superior Finish
Sealant Joint (by others)
United Coatings Wall-Bond NCB or Wind-Lock Transition Wrap or equal (by others)
ICF-17 Termination at Foundation Detail
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF and structural support
(by others)
Sealant (by others)
Master Wall Base Coat & Mesh
Superior Finish
Wind-Lock Transition Wrap or Architect-Approved Equal – extend approximately 1” (25 mm) above deck (by others)
Sealant (by others)
ICF-18 Termination at Decking
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Master Wall Base Coat & Mesh
Superior Finish
Coping Cap with continuous cleat and secondary water barrier (by others)
Extend Cap 2” (51 mm) min. over siding
Sealant (by others)
ICF-19 Cap Detail
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Slope 1:2 min. to shed water
Master Wall Base Coat & Mesh
Superior Finish
EPS Aesthetic Shape
Master Wall Adhesive
ICF-20 EPS Shape Detail
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
Master Wall Base Coat & Mesh
Superior Finish
Wrap Mesh 12” (305 mm) each side of corner
ICF-21 Corner Detail
Insulated Concrete Form (ICF) Coatings Conceptual Details
Corporate •••• P.O. Box 397 •••• Fortson •••• Georgia •••• 31808 •••• 800-755-0825 •••• FAX 706-569-6704 Technical •••• 800-760-2861•••• FAX 734-433-0930
These drawings relay the conceptual conditions of Master Wall Systems and are not the construction drawings. Ultimately the design and detailing of an entire wall system is the responsibility of a professional. These details will guide the design professional in the use of Master Wall Products. Master Wall disclaims design, warranty or construction intent or responsibility. Bold=Master Wall® Product. 2016 Master Wall Inc. ® 160301
ICF (by others)
EPS Aesthetic Band – Extend 2” (51 mm) min over roof step flashing, Keep 1” to 2” (25-51 mm) above roof surface
Set End Flashing in Sealant or use Kick Out flashing if “Exposed Tie” Application (by others) Roof System:
Roof Shingles (07300), roof felt turned up wall 4” (102 mm) min, roof step flashing and drip edge (by others)
ICF-22 Typical Roof/Wall Intersection
Recommended