View
1.194
Download
19
Category
Preview:
Citation preview
RE 00 208/11.01Replaces: 07.01
INDUSTRIAL HYDRAULICSHydraulic and electronic components
Bosc
h
Rexr
oth
Please take into account!
The colour code on the index page numbers aswell as the pages themselves refer to aRexroth product (blue) or Bosch product (red) .
Publisher Bosch Rexroth AGD-97813 Lohr a. MainZum Eisengießer 1 • D-97816 Lohr a. MainTelephone 0 93 52/18-0Telefax 0 93 52/18-23 58Telex 6 89 418-0eMail documentation@rexroth.deInternet www.boschrexroth.de
Document No. RE 00 208/11.01Replaces: 04.01
Printed by Schleunungdruck GmbHD-97828 Marktheidenfeld
Reprinting and translation, either in whole or inpart, only with the publisher's permission.
Subject to revision.
3
Contents Page
HYDRAULIC PUMPS .............................................................................................................. 7Axial piston units– Fixed/variable displacement pumps for open circuit .......................................................................................... 9– Variable displacement pumps for open or closed circuits ................................................................................. 11– Elektronic components for axial piston units ................................................................................................... 16External gear pumps ........................................................................................................................................ 17 18Internal gear pumps ........................................................................................................................................ 19 21Vane pumps ..................................................................................................................................................... 22 24Radial piston pumps ........................................................................................................................................ 25Combination pumps ........................................................................................................................................ 26
HYDRAULIC MOTORS ........................................................................................................ 27Axial piston units– Fixed motors .................................................................................................................................................. 28– Variable motors ............................................................................................................................................. 32– Switching motors ........................................................................................................................................... 33Planetary motors (positioning motors) ............................................................................................................ 34Radial piston excentric motors ........................................................................................................................ 35
MOTOR/PUMP ASSEMBLIESMotor/pump compact units MPU .................................................................................................................... 36Motor/pump assemblies .................................................................................................................................. 36
HYDRAULIC CYLINDERS .................................................................................................... 37Tie rod type ...................................................................................................................................................... 38 38Mill type .......................................................................................................................................................... 38 38
HYDRAULIC VALVESSwitching valves .............................................................................................................................................. 41– Isolation valves
• Check valves .............................................................................................................................................. 42 45• Isolator valves .......................................................................................................................................................... 46• Pre-fill valves .............................................................................................................................................. 48
– Directional valves• Directional poppet valves, direct operated ................................................................................................... 49• Directional poppet valves, direct operated (cartridge valves) ......................................................................... 50• Directional spool valves, direct operated – with manual, mechanical, fluidic or electrical operation ............... 51 54• Directional spool valves, direct operated (cartridge valves) ........................................................................... 50• Directional spool valves, pilot operated – with electro-hydraulic operation ................................................... 53 56• Valves with position switches .................................................................................................................................... 82• Valves with a mechanical position switches ............................................................................................................... 83
t
4
Contents Page
– Pressure valves• Pressure relief valves, direct and pilot operated ........................................................................................... 57 59• Pressure relief valves of sandwich plate design, direct and pilot operated ..................................................... 58 60• Pump safety block, pilot operated ............................................................................................................... 61• Pressure reducing valves, direct and pilot operated ...................................................................................... 62 64• Pressure sequence valves, direct and pilot operated ..................................................................................... 66 68• Pressure cut-off valves, pilot operated ......................................................................................................... 67 68• Load control unit ...................................................................................................................................................... 84
– Flow valves• Double throttle check valves (sandwich plate design) .................................................................................. 69 73• Throttle and throttle check valves ................................................................................................................ 70 73• 2-way flow control valves and rectifier sandwich plates ............................................................................... 71 74
– 2-way cartridge valves (logic elements)
• Directional function .................................................................................................................................... 75 76• Pressure relief and sequence functions ........................................................................................................ 77 78• Pressure reducing functions ........................................................................................................................ 79 80• 2-way special cartridge valves ................................................................................................................................... 81• 2-way cartridge valves with position switches ........................................................................................................... 83
Proportional, high response and servo valves .................................................................................................. 85– Proportional and servo valves
• Proportional and high response valves, direct and pilot operated ................................................................. 86 93• Proportional directional valves (cartridge valves) .......................................................................................... 88• Two and three stage servo valves ................................................................................................................ 92
– Proportional pressure control valves ............................................................................................................... 98 104– Proportional flow control valves ...................................................................................................................107 109
ELECTRONIC COMPONENTS, SYSTEMS AND ACCESSORIES.................................... 111Amplifier cards and modules– Analogue amplifier in Euro-card format ........................................................................................................112 116– Analogue amplifier of modular design ..........................................................................................................125 126– Analogue command value cards in Euro-card format .....................................................................................129– Analogue command value modules ..............................................................................................................130– Digital amplifiers in Euro-card format ...........................................................................................................131– Digital command value cards in Euro-card format .........................................................................................133Digitale control cards and controller assemblies– Digital control card VT-SWKD-2; DPCD .........................................................................................................133 138– Digital axis control VT-HNC100 ....................................................................................................................134– Digital controller assembly VT-HNC100-SEK ..................................................................................................135– Digital controller assembly IP252mH ............................................................................................................136Elektro-hydraulic systems– Closed loop control electronics
• Electronics for testing technology ..............................................................................................................139• Control technology for theatre applications ...............................................................................................140• Application specific electronics ........................................................................................................................ 128; 137
5
Contents Page
– Control systems• Control and automation technology for hydraulic units and systems ..........................................................141• Control systems SYDFE1; SYDFEE; SYDFEC .................................................................................................142
– Control electronics
• MX4 multi-axes CNC contol ......................................................................................................................143Accessories– Sensors and signal transmitters
• Pressure transducers and pressure indicators .............................................................................................144 145• Electronic signal transmitters ....................................................................................................................146 147
– Extended accessory programme
• Racks, card holders, card plugs and power supplies ...................................................................................148 149• Active plug .............................................................................................................................................................150• Field bus capable active plugs for hydraulic switching valves AS-I- field bus ..............................................................152• Test and service units ................................................................................................................................153 154
SIMULATION / ENGINEERING ......................................................................................... 155
CONTROL BLOCKS / PLATES ........................................................................................... 157Standardised and branch indendent control blocks .......................................................................................158 158Branch and customer specific control blocks .................................................................................................158 158Compact hydraulics .......................................................................................................................................158Standard manifold blocks ..............................................................................................................................159
MEASUREMENT AND MONITORING EQUIPMENT..................................................... 161Pressure indicators– Pressure gauge isolator valves and pressure gauge selector switches ............................................................162Pressure switches– Bourden tube pressure switches ...................................................................................................................162– Piston type pressure switches .......................................................................................................................163 163
FILTERS ................................................................................................................................ 161Pressure filters ...............................................................................................................................................164Return filters ..................................................................................................................................................164
ACCUMULATORS AND ACCUMULATOR ACCESSORIES ............................................ 165Accumulator assemblies, accumulator safety and isolator blocks .................................................................166 167Hydro-pneumatic accumulators ...................................................................................................................................167Safety valves, accumulator loading valves ...................................................................................................................168
HYDRAULIC POWER UNITS AND ACCESSORIES ........................................................ 169Power units– Standard power units and hydraulic reservoirs, Project power units ...............................................................170 173– Clamping and drive modules ........................................................................................................................174– Filter/cooling circulation units ......................................................................................................................175Accessories– Pump mounting brackets .............................................................................................................................176
6
Notes
7
HYDRAULIC PUMPS
Axial piston pumps
Axial piston pumps of swash plate andbent axis design are available for themedium and high pressure range.
Design variants, in the power range and inthe closed-loop and control possiblitiesguarantee optimum solutions for stationaryapplications.
The performance profile
• Displacement volumes:
10 to 1000 cm3
• Nominal pressure: Up to 420 bar
• Maximum speed up to 5600 min–1
• Maximum power 933 kW
• Modular controllers:Hydro-mechanical and electro-hydrauliccontrollers
External gear pumps
Gear pumps count as one of the hydraulicclassics.
Single pumps, multiple pumps and noisereduced silence pumps offer in five buildseries virtually limitless applicationpossiblities.
The performance profile
• Displacement volumes of 0.17 to 56 cm3
• Nominal pressure up to 280 bar
• Pressure dependent gap sealing and highpression manufacturing stand foroptimum efficiency
• Versions with differing flanges, shafts,built-on valves and multiple pumpcombinations are available
8
HYDRAULIC PUMPS
Internal gear pumps
The internal gear pumps can becontinuously operated at up to 330 bar(depending on the build size).
Due to the compact design a particularlyhigh power density results and a minimumof space is required.
The performance profile
• Displacement volumes of 1,7 to 250 cm3
• Continuous pressure up to 330 bar
• Pumps can be combined with each other
• Low flow pulses and low running noisedue to the internal gears
• Very good volumetric efficiency due tothe hydraulic gap compensation of theaxial and radial sealing gap
Vane pumps
The vane pump series are mainly used inthe lower and medium pressure ranges.
The performance profileVariable pumps
• Displacment volumes of 10 to 164 cm3
• Continuous pressure up to 210 bar
• Multiple pump combinations are possible
• Direct or pilot operated pressurecontroller
• Pressure, flow controllers
• Electro-hydraulically adjustable
Fixed displacement pumps
• Displacement volumes of 18 to 193 cm3
• Continuous pressure up to 210 bar
• Multiple pump combinations are possible
• Low operating noise
• Maintenance friendly
Radial piston pumps
Radial piston pumps are used for the highpressure range (operating pressures up to700 bar). They are valve controlled self-priming pumps with a fixed displacement.
The performance profile
• Displacement volumes of 0.40 to 20 cm3
• Operating pressure up to 700 bar
• Hydro-static bearing unloading for a longservice life
• Multiple pump combinations are possible
• Suitable for use with special fluids
9
Fixed displacement pumpsType A2FO
Fixed displacement pumps
• Nominal pressure:Nominal size 5: 315 barNominal sizes 10 to 200: 400 barNominal sizes 250 to 1000: 350 bar
• Peak pressure:Nominal size 5: 350 barNominal sizes 10 to 200: 450 barNominal sizes 250 to 1000: 400 bar
• Series 6
• Open circuit
• Robust and short taper roller bearing
• Standard fixed displacement pump suitable for all applications inthe open circuit
• Service ports SAE or threaded
• Cylindrical shaft end with splined or keyed shaft
• Long-life bearings possible (nominal sizes 250 to 1000)
Type A2FO
Nominal sizes 5 to 1000
Axial tapered piston bent-axis design
Detailed information:
RE 91 401
Nominal size 5 10 12 16 23 28Displacement Vg cm3 4.93 10.3 12 16 22.9 28.1Speed 1) nmax min–1 5600 3150 3150 3150 2500 2500Flow at nmax qV max L/min 27 32 37 49 56 69Power ∆p = 400 bar Pmax kW 9.6 2) 22 25 34 38 47Torque ∆p = 400 bar Tmax Nm 24.7 2) 65 76 100 144 178Weight (approx.) m kg 2.5 5.4 5.4 5.4 9.5 9.5
Nominal size 32 45 56 63 80 90Displacement Vg cm3 32 45.6 56.1 63 80.4 90Speed 1) nmax min–1 2500 2240 2000 2000 1800 1800Flow at nmax qV max L/min 78 100 110 123 141 158Power ∆p = 400 bar Pmax kW 53 68 75 84 96 108Torque ∆p = 400 bar Tmax Nm 203 290 356 400 511 572Weight (approx.) m kg 9.5 13.5 18 18 23 23
Nominal size 107 125 160 180 200Displacement Vg cm3 106.7 125 160.4 180 200Speed 1) nmax min–1 1600 1600 1450 1450 1550Flow at nmax qV max L/min 167 196 228 255 304Power ∆p = 400 bar Pmax kW 114 133 155 174 207Torque ∆p = 400 bar Tmax Nm 678 795 1020 1145 1272Weight (approx.) m kg 32 32 45 45 66
1) These values are valid at an absolutepressure of 1 bar in suction port S
2) ∆p = 315 bar
Nenngröße 250 355 500 710 1000Displacement Vg cm3 250 355 500 710 1000Speed 1) nmax min–1 1500 1320 1200 1200 950Flow at nmax qV max L/min 375 469 600 826 950Power ∆p = 350 bar Pmax kW 219 273 350 497 554Torque ∆p = 350 bar Tmax Nm 1391 1976 2785 3955 5570Weight (approx.) m kg 73 110 155 322 336 = Preferred product range
10
Fixed displacement pumpsType A4FO
Fixed displacement pumps A4FO
• Nominal pressure:Nominal sizes 16 to 40: 400 barNominal sizes 71 to 500: 350 bar
• Peak pressure:Nominal sizes 16 to 40: 450 barNominal sizes 71 to 500: 400 bar
• Open circuit
• Series 3 (nominal sizes 16 to 40 and 125 to 500)Series 1 (nominal size 71)
• Long bearing life
• Good suction characteristics
• Pump combinations possible
• Optional through-drive for mounting further pumps
• Operation using HF pressure fluids is possible with reducedtechnial data (nominal sizes 71 to 500)
Type A4FO
Nominal sizes 16 to 500
Axial piston swashplate design
Detailed information:
RE 91 455
Nominal size 16 22 28 40
Displacement Vg cm3 16 22 28 40
Speed 1) nmax min–1 4000 3600 3000 2750
Flow at nmax qV max L/min 64 79 84 110
Power ∆p = 400 bar Pmax kW 43 53 56 73
Torque ∆p = 400 bar Tmax Nm 102 140 178 254
Weight (approx.) m kg 13.5 13.5 13.5 16.5
1) These values are valid at an absolutepressure of 1 bar in suction port S
2) ∆p = 420 bar
Nominal size 71 125 250 500
Displacement Vg cm3 71 125 250 500
Speed 1) nmax min–1 2200 1800 1500 1320
Flow at nmax qV max L/min 152 225 375 660
Power ∆p = 350 bar Pmax kW 91 131 219 385
Torque ∆p = 350 bar Tmax Nm 395 696 1391 2783
Weight (approx.) m kg 34 61 120 220
= Preferred product range
11
–Vg max
+Vg max
s (β)
s (β)
–Vg max
+Vg max
U
U
–Vg max
+Vg max
pSt
pSt
pB
Vg maxVg min
Variable displacement pumpsType A4VSG
Variable displacement pumps
• Nominal pressure: 350 bar
• Peak pressure: 400 bar
• Series 1 and 3
• Closed circuit
• Mainly for use in stationary, industrial applications
• Valve block for safeguarding the closed circuit
• Auxiliary pumps for the boost and pilot oil circuit or an additio-nal axial piston pump of up to the same size (combinationpump) can be connected to the through-drive
• Secondary control
Type A4VSG
Nominal sizes 40 to 1000
Axial piston swashplate design
Detailed information:
RE 92 100
Pump for the semi-closed circuit,see RE 92 110
Hydrostatic gearbox, secondary control withA4VS components, see RE 92 055
MAManual control
EMElectromotivecontrol
HWHydraulic flow control,position-related
EO1/EO2Hydraulic flow control(proportional valve)
HS/HS3Hydraulic flow control(servo/proportional valve)
HM1/2Hydraulic flow control,flow-related
HDHydraulic control, pilotpressure-related
DS1Speed regulation, secondarycontrolled
DRPressure controller
DPPressure controller forparallel operation
Vg = DisplacementpSt = Pilot pressurepB = Operating pressures = Actuator travelU = Control voltage
Nominal size 40 71 125 180 250
Displacement Vg max cm3 40 71 125 180 250
Speed nmax min–1 3700 3200 2600 2400 2200
Flow at nmax qV max L/min 148 227 325 432 550
Power ∆p = 350 bar Pmax kW 86 132 190 252 321
Torque ∆p = 350 bar Tmax Nm 223 395 695 1002 1391
Weight (approx.) EO+valve block m kg 47 60 100 114 214
Nominal size 355 500 750 1000
Displacement Vg max cm3 355 500 750 1000
Speed nmax min–1 2000 1800 1600 1600
Flow at nmax qV max L/min 710 900 1200 1600
Power ∆p = 350 bar Pmax kW 414 525 699 933
Torque ∆p = 350 bar Tmax Nm 1975 2783 4173 5565
Weight (approx.) EO+valve block m kg 237 350 500 630
= Preferred product range
12
pB
Vg maxVg min
pB
Vg maxVg min
pB
Vg maxVg min Vg maxVg min
pB
s
Vg min Vg max
U
Vg min Vg max
U
Vg min Vg max
pSt
Vg min Vg max
Variable displacement pumpsType A4VSO
Types A4VSO, A4VSLO
Nominal sizes 40 to 1000
Axial piston swashplate design
Detailed information:RE 92 050
Hydraostatic gearbox, secondary controlwith A4VS components, see RE 92 055
Variable displacement pumps
• Nominal pressure 350 bar
• Peak pressure 400 bar
• Series 1 and 3
• Open circuit
• Use for stationary applications
• Long bearing life
• Comprehensive controller and adjustment element productrange
• Secondary control
• Through-drive option
DRPressure controller
DPPressure controller for paralleloperation
LR2Power controller
LR3Power controller, remote controlled
DFRPressure and flow controller
FRFlow controller
MAManual control
EMElectromotive adjustment
HDHydraulic control, pilotpressure-related
EO1/EO2Hydraulic displacementcontrol (proportional valve)
HS/HS3Hydraulic displacementcontrol (servo/proportionalvalve)
HM1/2Hydraulic displacementcontrol, flow-related
Vg = DisplacementpB = Operating pressurepSt = Pilot pressures = Actuator travelß = Swivel angleU = Control voltage
1) These valves are valid at an absolutepressure of 1 bar in suction port S
Nominal size A4VSO 40 71 125 180 250Displacement Vg max cm3 40 71 125 180 250Speed 1) nmax min–1 2600 2200 1800 1800 1500Flow at nmax qV max L/min 104 156 225 324 375Power ∆p = 350 bar Pmax kW 60 91 131 189 218Torque ∆p = 350 bar Tmax Nm 222 395 695 1002 1391Weight (approx.) press. controller m kg 39 53 88 102 184
Nominal size A4VSO 355 500 750 1000Displacement Vg max cm3 355 500 750 1000Speed 1) nmax min–1 1500 1320 1200 1000Flow at nmax qV max L/min 533 660 900 1000Power ∆p = 350 bar Pmax kW 311 385 525 583Torque ∆p = 350 bar Tmax Nm 1976 2783 4174 5565Weight (approx.) press. controller m kg 207 320 460 605
DS1Speed control, secondarycontrol
= Preferred product range
13
pSt
Vg maxVg min
pB
Vg maxVg min
pB
Vg maxVg min
pB
Vg maxVg min
Vg, pB
pSoll U
pB
I
Variable displacement pumpsType A10VSO
Variable displacement pumps
• Nominal pressure 280 bar (NS 18 to 140)
• Nominal pressure 250 bar (NS 10)
• Peak pressure 350 bar (NS 18 to 140)
• Peak pressure 315 bar (NS 10)
• Open circuit
• Series 3 (NS 18 to 140)
• Series 5 (NS 10)
• Long bearing life
• Comprehensive controller and adjustment element productrange
• Through-drive option for mounting further pumps of up to thesame size (combination pump, not NS 10)
1) These values are valid at an absolutepressure of 1 bar in suction port S
2) ∆p = 250 bar
Nominal size 10 18 28 45Displacement Vg max cm3 10.5 18 28 45Speed 1) nmax min–1 3600 3300 3000 2600Flow at nmax qV max L/min 37.8 59.4 84 117Power ∆p = 280 bar Pmax kW 15.7 2) 27.7 39 55Torque ∆p = 280 bar Tmax Nm 41.7 2) 80 125 200Weight (approx.) press. controller m kg 8 12 15 21
Nominal size 71 100 140Displacement Vg max cm3 71 100 140Speed 1) nmax min–1 2200 2000 1800Flow at nmax qV max L/min 156 200 252Power ∆p = 280 bar Pmax kW 73 93 118Torque ∆p = 280 bar Tmax Nm 316 445 623Weight (approx.) press. controller m kg 33 45 60
Type A10VSO
Nominal sizes 10 to 140
Axial piston swashplate design
Detailed information:NS 10: RE 92 713NS 18: RE 92 712NS 28 to 140: RE 92 711
Vg = DisplacementU = Control voltagepB = Operating pressurepSt = Pilot pressureI = Current
DRPressure controller
DFEPressure, flow controller,electronic
DFLRPressure, flow and powercontroller
DFRPressure and flow controller
FHDDisplacement controller, pilotpressure-related, withclosed-loop pressure control
EDElectro-hydraulic closed-looppressure control
= Preferred product range
14
I
Vg min Vg max
pB
Vg maxVg min
pB
Vg min Vg max
pSt
Vg min Vg max
Variable displacement pumpsType A7VO
Type A7VO
Nominal sizes 55 to 1000
Axial tapered piston bent-axis design
Detailed information:• NS 55 to 160 – RE 92 202
• NS 250 to 1000 – RE 92 203
Variable displacement pumps
• Nominal pressure 350 bar
• Peak pressure 400 bar
• Series 6
• Open circuit
• Robust and proven design for a multitude of open-circuitapplications
• Long-life bearing for increased bearing life possible(NS 250 to 1000)
• Visual or electrical swivel angle indicator on request(NS 250 to 1000)
• Comprehensive controller and adjustment element productrange
Nominal size 250 355 500 1000Displacement Vg max cm3 250 355 500 1000Speed 1) nmax min–1 1500 1320 1200 950Flow at nmax qV max L/min 375 469 600 950Power ∆p = 350 bar Pmax kW 212 265 340 538Torque ∆p = 350 bar Tmax Nm 1391 1976 2783 5565Weight (approx.) m kg 102 173 234 450
LRPower controller
HDHydraulic adjustmentelement, pressure-related
EPEl. adjustment element withproportional solenoid
DRPressure controller
1) These valves are valid at an absolutepressure of 1 bar in suction port S
Vg = DisplacementpB = Operating pressurepSt = Pilot pressureI = Control current
Nominal size 55 80 107 160Displacement Vg max cm3 54,8 80 107 160Speed 1) nmax min–1 2500 2240 2150 1900Flow at nmax qV max L/min 133 174 223 295Power ∆p = 350 bar Pmax kW 80 105 134 177Torque ∆p = 350 bar Tmax Nm 305 446 596 891Weight (approx.) m kg 25 40 49 71
= Preferred product range
15
–Vg max
+Vg max
U
U
Variable displacement pumpsType A4VB
Variable displacement pumps A4VB
• Nominal pressure: 420 bar
• Peak pressure: 450 bar
• Series 3
• Variable displacement pump for the closed circuit and preloadoperation
Nominal size 450 675
Displacement Vg cm3 456 675
Speed nmax min–1 1800 1600
Flow at nmax qV max L/min 821 1080
Power ∆p = 420 bar Pmax kW 574 756
Torque ∆p = 420 bar Tmax Nm 3044 4508
Weight (approx.) m kg 420
Type A4VB
Nominal sizes 450 and 675
Axial piston swashplate design
Detailed information:RE 92 120
HS/HS3Hydraulic displacementadjustment element (servo/proportional valve)
HM1/2Hydraulic displacementadjustment element, flow-related
Vg = DisplacementpSt = Pilot pressureU = Control voltage
= Preferred product range
16
Electronics for axial piston units
Component typeSenorsHM 12, HM 13 Pressure transducersHM 14, HM 15 Pressure transducersHM 16 Pressure transducersAnalogue open-loop control electronicsVT 2000 Amplifiers for proportional valvesVT 5003 and VT 5004 Amplifiers for proportional valvesVT 5010 Amplifiers for proportional valvesVT-VSPA1(K)-1 Amplifiers for proportional valvesAnalogue closed-loop control electronicsVT 5035 Amplifiers for flow controlVT 11019 Amplifiers for flow controlVT-SR7 Amplifiers for flow controlVT 12000 Speed control of secondary unitsSYDFE1, SYDFEE, SYDFEC Control systems for controlling A10VSO…Digital closed-loop control electronicsVT 12350 Control systems for controlling A4VS…HS3VT 12352 Control systems for controlling A2V…EO1SYHNC100-SEK Controller assemblies for A4VS…DS1(E) secondary unitsAccessoriesVT 3002 Card holderVT 12302 Closed card holderVT 12304 Interface converterVT 19101 to 19110 19-inch rackVT-NE30 to VT-NE32 Compact power supply unitsVTS 0102 FUW1 frequency/voltage converterVT 12321 BB-3 hand-held control boxBODIV PC programme for digital amplifier cards
Overview of electronic components and systems suitable for axialpiston units in stationary applications
= P
refe
rred
prod
uct r
ange
Detailedinformation:
RE 29 933RE 29 932RE 30 266
RE 29 904RE 29 945RE 29 945RE 30 111
RE 29 955RE 29 763RE 29 993RE 29 775RE 30 024, RE 30 030, RE 30 027
RE 30 021RE 30 020RE 30 141
RE 29 928RE 30 103RE 30 104RE 29 768RE 29 929RE 29 761RE 29 798RE 29 899
17
External gear pumpsType 1PF2G
Fixed displacement pumps
• Nominal pressure 250 bar
• Plain bearings for heavy loads
• Single-block bearing
• Drive shafts according to ISO or SAE
• Combination of several pumps possible
• Line connections:Connecting flanges or pipe thread
Type 1PF2G
Nominal sizes 4 to 45
Detailed information:• Frame size G2, series 4X RE 10 030• Frame size G3, series 3X RE 10 039
Frame size G2, series 4XNominal size 4 5 8 11 14 16 19 22
Displacement Vg max cm3 4 5.5 8.2 11 14.1 16.2 19 22.4
Operating pressure pmax bar 250 250 250 250 250 250 240 210
Power at 1450 min-1 P kW 3 4 6.5 7.5 9 11 12.5 13
Speed range 1) n min-1 500 to 5000
Weight m kg 2.4 2.5 2.6 2.7 2.8 2.9 3.1 3.3
Frame size G3, series 3XNominal size 20 23 26 29 32 38 45
Displacement Vg max cm3 20.9 23.4 25.9 30.1 32.6 37.6 45.2
Operating pressure pmax bar 260 260 260 240 220 210 180
Power at 1450 min-1 P kW 14.2 16 16.8 19.5 19.5 21.3 22.2
Speed range 1) n min-1 500 to 3600
Weight m kg 3.9 3.9 3.9 4.3 4.3 4.3 6.2 1) Depending on size
18
External gear pumps
Fixed displacement pumps• Nominal pressure 250 bar
• Plain bearings for high loads
• Bearing bushes
• Drive shafts to ISO or SAE
• Combination pumps are possible
• Pipe connections:Flanges or threaded connections
Detailed information:AKY 001/1
1) Nominal size dependent
Build size FNominal size 4 5 8 11 14 16 19 22
Displacement volume Vg max cm3 4 5.5 8 11 14 16 19 22.5
Operating pressure pmax bar 280 280 280 280 280 280 230 210
Power at 1450 min-1 Phyd kW 2.7 3.72 5.41 7.44 9.47 10.8 10.6 11.4
Speed range 1) n min-1 500 to 4000
Weight m kg 2.8 2.85 2.9 3 3.2 3.4 3.6 3.8
Build size BNominal size 1 2 3 4 5
Displacement volume Vg max cm3 1 2 3 3.8 4.6
Operating pressure pmax bar 230 230 230 210 160
Power at 1450 min-1 Phyd kW 0.56 1.12 1.67 1.93 1.78
Speed range 1) n min-1 750 to 6000
Weight m kg 0.8 0.86 0.9 0.9 0.9
Build size GNominal size 22 28 32 38 45 56
Displacement volume Vg max cm3 22.5 28 32 38 45 56
Operating pressure pmax bar 250 250 250 230 200 160
Power at 1450 min-1 Phyd kW 13.6 16.9 19.4 21.2 21.8 21.7
Speed range 1) n min-1 500 to 3000
Weight m kg 9 9.2 9.4 9.7 9.9 10.4
= Preferred product range
19
Internal gear pumpsType PGF
Fixed displacement pumps
• Maximum pressure 210 bar
• Very low operating noise
• Low flow pulsation
• High efficiency even at low viscosity due to sealing gapcompensation
• Suitable for a wide speed and viscosity range
• Combination of several pumps possible
• Can be combined with axial piston pumps and with vane pumps
• Available as completely assembled compact drive unit (pumpwith electric motor) type "MPU"
Type PGF
Nominal sizes 1.7 to 40
Detailed information:RE 10 213
Frame size 3Nominal size 20 22 25 32 40
Displacement Vg max cm3 20.6 22.2 25.4 32.5 40.5
Operating pressure 3) pmax bar 210 210 210 210 180
Power 1) (1450 min-1) P kW 11.7 12.5 14.1 18.1 20.0
Speed range n min-1 On request 2)
Weight 4) m kg 3.3 3.7 4.1 4.5 4.9
Frame size 2Nominal size 16 19 22
Displacement Vg max cm3 16 18,9 22
Operating pressure 3) pmax bar 210 210 180
Power 1) (1450 min-1) P kW 9,3 10.9 12,4
Speed range n min-1 On request 2)
Weight 4) m kg 2.7 2.9 3.1
Frame size 2Nominal size 6 8 11 13
Displacement Vg max cm3 6.5 8.2 11 13.3
Operating pressure 3) pmax bar 210
Power 1) (1450 min-1) P kW 4 5.1 6.6 8
Speed range n min-1 On request 2)
Weight 4) m kg 2.1 2.2 2.4 2.6
Frame size 1Nominal size 1.7 2.2 2.8 3.2 4.1 5.0
Displacement Vg max cm3 1.7 2.2 2.8 3.2 4.1 5.0
Operating pressure 3) pmax bar 180 210 210 210 210 180
Power 1) (1450 min-1) P kW 1.2 1.8 2 2.2 2 3.1
Speed range n min-1 On request 2)
Weight 4) m kg 0.8 0.9 1.0 1.0 1.1 1.3
1) At max. continuous operating pressure;Pressure fluid temperatureϑ = 50 °C
2) Depending on size3) Continuous4) For pump with 2-hole mounting type
= Preferred product range
20
Internal gear pumpType PGH
Fixed displacement pump
• Maximum pressure: up to 350 bar
• Very low operating noise
• Low flow pulsation
• High efficiency even at low speed and viscosity due to sealinggap compensation
• Suitable for a wide speed and viscosity range
• All frame sizes and nominal sizes can be combined with eachother
• Can be combined with vane pumps and axial piston pumps
Type PGH
Nominal sizes 5 to 250
Detailed information:RE 10 223
Frame size 2Nominal size 5 6.3 8
Displacement Vg max cm3 5.2 6.5 8.2
Operating pressure 1) pmax bar 350
Speed nmin min-1 600
Speed nmax min-1 3000
Weight m kg 4.3 4.8 5
Frame size 3Nominal size 11 13 16
Displacement Vg max cm3 11 13,3 16
Operating pressure 1) pmax bar 350
Speed nmin min-1 600
Speed nmax min-1 3000
Weight m kg 5.9 6.2 6.4
Frame size 4Nominal size 20 25 32 40 50 63 80 100
Displacement Vg max cm3 20,1 25,3 32,7 40,1 50,7 65,5 80,3 101,4
Operating pressure 1) pmax bar 315 315 315 315 315 250 250 210
Speed nmin min-1 500 500 500 500 500 400 400 400
Speed nmax min-1 3000 3000 3000 2600 2600 2600 2200 2200
Weight m kg 13,5 14 14,5 15 16 17 18,5 20
Frame size 5Nominal size 63 80 100 125 160 200 250
Displacement Vg max cm3 64.7 81.4 100.2 125.3 162.8 200.4 250.5
Operating pressure 1) pmax bar 315 315 315 315 250 210 160
Speed nmin min-1 400 400 400 400 300 300 300
Speed nmax min-1 2600 2200 2200 2200 1800 1800 1800
Weight m kg 39 40.5 42.5 45 49 52.5 57.5 1) Intermittent
= Preferred product range
21
Internal gear pumpType IPK
Fixed displacement pump
• Maximum pressure: up to 330 bar 1)
• Very low operating noise
• Low flow pulsation
• High efficiency even at low viscosity
• Combination pumps are possible
Type IPK
Nominal size 3,5 to 250
Detailed information:on request
1) Continuous2) At max. operating pressure (bar);
n = 1450 min, ϑ = 40 °C, ν = 46 mm2/s
Frame size 3Nominal size 3,5 5 6,3 8 10
Displacement Vg max cm3 3,5 5 6,3 8 10Operating pressure 1) pmax bar 330 330 330 330 330Power 2) (1450 min-1) P kW 3,0 4,1 5,0 6,5 8,5Speed range min/max n min-1 600/3200Weight m kg 4,0 4,2 4,4 4,6 4,8
Frame size 4Nominal size 13,0 16,0 20,0 25,0 32,0
Displacement Vg max cm3 13,0 16,0 20,0 25,0 32,0Operating pressurek 1) pmax bar 330 330 330 300 250Power 2) (1450 min-1) P kW 11,5 13,5 17,5 20,2 22,0Speed range min/max n min-1 600/3200 600/2800Weight m kg 8,6 9,0 9,6 10,2 11,0
Frame size 5Nominal size 40,0 50,0 64,0
Displacement Vg max cm3 40,0 50,0 64,0Operating pressure 1) pmax bar 310 280 230Power 2) (1450 min-1) P kW 33,0 38,0 38,5Speed range min/max n min-1 600/2200Weight m kg 16,3 17,4 18,7
Frame size 6Nominal size 80,0 100,0 125,0
Displacement Vg max cm3 80,0 100,0 125,0Operating pressure 1) pmax bar 280 250 210Power 2) (1450 min-1) P kW 60,0 66,0 70,0Speed range min/max n min-1 600/1800Weight m kg 30,7 32,6 35,0
Frame size 7Nominal size 160,0 200,0 250,0
Displacement Vg max cm3 160,0 200,0 250,0Operating pressure 1) pmax bar 280 250 210Power 2) (1450 min-1) P kW 120,0 130,0 170,0Speed range min/max n min-1 600/1800Weight m kg 50,0 54,0 59,0
22
Vane pumpsTypes PVV, PVQ
Fixed displacement pumps• Maximum pressure 210 bar
• Low operating noise
• Low flow pulsation
• Suitable for a wide speed and viscosity range
• Combination of several pumps possible
• Can be combined with axial piston pumps and vane pumps
Types PVV, PVQNominal sizes 18 to 193
Detailed information:RE 10 335
Frame size 5Nominal size 139 154 162 183 193
Displacement Vg max cm3 139 154 162 183 193
Operating pressure 3) pmax bar 175
Power 1) (1450 min-1) P kW 69 75 80 90 95
Speed range n min-1 On request 2)
Weight m kg 34
1) At maximum continuous operatingpressure; pressure fluid temperatureϑ = 50 °C
2) Depending on size3) Continuous (for type PVQ)
Frame size 1Nominal size 18 27 36 40 46
Displacement Vg max cm3 18 27 36 40 46
Operating pressure 3) pmax bar 210 210 210 160 140
Power 1) (1450 min-1) P kW 11 16 21 18 18
Speed range n min-1 On request 2)
Weight m kg 12
Frame size 2Nominal size 40 45 55 60 68
Displacement Vg max cm3 40 45 55 60 68
Operating pressure 3) pmax bar 210
Power 1) (1450 min-1) P kW 22 26 32 34 37
Speed range n min-1 On request 2)
Weight m kg 14,8
Frame size 4Nominal size 69 82 98 113 122
Displacement Vg max cm3 69 82 98 113 122
Operating pressure 3) pmax bar 210
Power 1) (1450 min-1) P kW 38 45 55 60 65
Speed range n min-1 On request 2)
Weight m kg 23
= Preferred product range
23
Vane pumps type PV7..., pilot operatedVane pumps type PV7...A, direct operated
Variable displacement pumps , pilot operated
• Variable displacement• Low operating noise• Pressue and flow can be controlled• Controller adjustment element can optionally be locked• Also available as completely assembled compact drive unit
(pump with electric motor) type "MPU"• Low hysteresis• Very short control times• Pump combinations possible with standard pumps• Mounting and connection dimensions according to
– VDMA 24 560/1– ISO 3019/2
Type PV7..., pilot operated
Nominal sizes 14 to 150
Nominal pressure 160 bar
Detailed information:RE 10 515
Frame size 40 63 100Displacement Vg max cm3 45 71 71 94 118 150
Operating pressure pmax bar 160 80 160 80 160 80Power at 1450 min–1 Pmax kW 20,5 17 34 22 54 35Speed range n min–1 900 to 1800Weight m kg 30 37 56
Variable displacement pumps, direct operated
• Very short control times
• Low operating noise
• Low zero-stroke power
• Mounting and connection dimensions according toVDMA 24 560/1 and ISO 3019/2
• Good efficiency
• Also availabe as completely assembled compact drive unit(pump with electric motor) type "MPU"
• Pump combinations possible
Type PV7...A, direct operated
Nominal sizes 10 to 25
Nominal pressure 100 bar
Detailed information:RE 10 520RE 10 521
Frame size 10 16 25Displacement Vg max cm3 14 20 20 30 30 45
Operating pressure pmax bar 160 100 160 80 160 80Power at 1450 min–1 Pmax kW 6.3 5.8 10 7.1 13.7 10.5Speed range n min–1 900 to 1800Weight m kg 12.5 17 21
Frame size 06 20
Displacement Vg max cm3 10 14 20 25
Operating pressure pmax bar 100 70 100 100
Power at 1450 min–1 Pmax kW 2.5 2.7 5 6
Speed range n min–1 1000 to 1800
Weight m kg 6.3 11.4 11.4= Preferred product range
24
Variable vane pumpsType VPV
Variable vane pumps
• Maximum pressure 210 bar
• Low operating noise
• Axial gap compensation for high efficiency
• Combination pumps are possible
Detailed information:AKY 003/41) At 210 bar
Nominal size 16 25 32 45 63
Displacement volume Vg max cm3 16.8 27.4 32.0 47.3 64.4
Operating pressure pmax bar 210
Power 1) (1450 min-1) P kW 3.0 3.6 3.6 6.3 6.9
Speed range n min-1 900 to 1800
Weight m kg 16.5 28 28 58 58
Nominal size 80 100 130 164
Displacement volume Vg max cm3 82.3 99.0 131.0 164.0
Operating pressure 3) pmax bar 210
Power 1) (1450 min-1) P kW 6.9 10.4 10.6 10.6
Speed range n min-1 900 to 1800
Weight m kg 58 113 113 113
25
Radial piston pumpsTypes R4, R4-Mini
Fixed displacement pumps
• Nominal pressure 700 bar
• Self-aspirating, valve-controlled
• Very low noise
• Long bearing life due to hydro-dynamically lubricated plainbearings
• Several pressure ports with different cylinder combinationspossible
• Can be combined with fixed and variable displacement vane,gear and axial piston pumps
• 14 nominal sizes, favourable graduations for optimum matchingto the application
Type R4
Nominal sizes 1.6 to 20.0
Radial piston pump with 3, 5 or 10 pistons
Detailed information:RE 11 263
Fixed displacement pumps
• Nominal pressure 700 bar
• Very compact build, hence installation-friendly dimensions
• 5 nominal sizes
• Piston/cylinder kits also available
Nominal size 8.0 10.0 16.0 20.0
Displacement Vg max cm3 8.03 9.71 16.07 19.43
Operating pressure pmax bar 500
Power at 1450 min-1 P kW 10.9 12.9 21.2 25.3
Speed range n min-1 1000 to 2000
Weight m kg 8.6 8.6 12.7 12.7
Type R4-MiniNominal sizes 0.4 to 2.0
Radial piston pump with 3 pistons
Detailed information:RE 11 2601) Depending on size
Nominal size 0.4 0.63 1.0 1.6 2.0
Displacement Vg max cm3 0.4 0.63 1.0 1.6 2.0
Operating pressure pmax bar 700 700 450 250 175
Power at 1450 min-1 P kW 0.66 1.15 1.14 1.06 0.86
Speed range 1) n min-1 1000 to 3400
Weight m kg 2.6
Nominal size 1.6 2.0 2.5 3.15 4.0
Displacement Vg max cm3 1.51 2.14 2.59 3.57 4.32
Operating pressure pmax bar 700
Power at 1450 min-1 P kW 2.9 4.1 4.9 6.8 8.1
Speed range n min-1 1000 to 2000
Weight m kg 6.8 6.8 6.8 8.6 8.6
Nominal size 6.3 8.0 3.15 5.0 6.3
Displacement Vg max cm3 7.14 8.63 3.39 4.82 5.83
Operating pressure pmax bar 700 700 500 500 500
Power at 1450 min-1 P kW 13.6 16.1 4.7 6.7 7.9
Speed range n min-1 1000 to 2000
Weight m kg 12.7 12.7 6.8 6.8 6.8
= Preferred product range
26
Combination pumps
Fixed displacement pump + Fixed displacement pump
Variable displacement pump + Fixed displacement pump
Variable displacement pump + Variable displacement pumpNumerous combination options
Combination pumps
Detailed information on request
• = included in product range
– = not available
Multiple combinations on request
PV7
PGH
/PG
F
R4 R4 M
ini
G2
G3
A10
PVV/
PVQ
Rear pump
Fron
t pum
p
PV7 • • • • • • • •PGH/PGF – • – – • – • •R4 – – – – • • – –
G2 – – – – • – – –
G3 – – – – • • – –
A10 – • – – • • • •
= Preferred product range
27
HYDRAULIC MOTORS
Axial piston motors
Swash plate and bent axis axial pistonmotors are available for the medium andhigh pressure ranges.
Our proven hydrostatic drives for stationaryapplications are robust, reliable, have along service life, have low noise emissions,and high efficiency as well as beingeconomical.
The performance profile
• Swept volumes of 5 to 1000 cm3
• Nominal pressures up to 400 bar
• Max. speed up to 10000 min–1
• Torques up to 5570 Nm
Radial piston eccentric motors
Radial piston eccentric motors of the typesMR.. are externally pressurised fixeddisplacement hydraulic motors.
The direction of rotation can be clockwiseor anti-clockwise as well as bi-directional.
The performance profile
• Swept volumes up to 10802 cm3
• Max. Speeds up to 800 min–1
• Continuous power up to 370 kW
• Torques up to 40000 Nm
28
Fixed displacement motorsType A2FM
Type A2FM
Nominal sizes 5 to 1000
Axial tapered piston bent-axis design
Detailed information:RE 91 001
Fixed displacement motors
• Nominal pressure: NS 5: 315 bar; NS 10 to 200: 400 bar;NS 250 to 1000: 350 bar
• Peak pressure: NS 5: 350 bar; NS 10 to 200: 450 barNS 250 to 1000: 400 bar
• Series 6• Open and closed circuit• Standard motor suitable for all applications• Brake valves can be directly fitted• Integrated or built-on flushing valves• Suitable for pump operation in the closed circuit• Long-life bearing possible (NS 250 to 1000)
1) ∆p = 315 bar2) ∆p = 350 bar
Nominal size 5 10 12 16 23 28
Swept volume Vg cm3 4.93 10.3 12.0 16.0 22.9 28.1
Speed nmax min–1 10000 8000 8000 8000 6300 6300
Inlet flow qV max L/min 49 82 96 128 144 176
Power ∆p = 400 bar Pmax kW 26 1) 55 64 85 96 118
Torque ∆p = 400 bar T Nm 25 1) 65 76 100 144 178
Weight (approx.) m kg 2.5 5.4 5.4 5.4 9.5 9.5
Nominal size
Swept volume Vg cm3 32 45.6 56.1 63 80.4 90
Speed nmax min–1 6300 5600 5000 5000 4500 4500
Inlet flow qV max L/min 201 255 280 315 360 405
Power ∆p = 400 bar Pmax kW 134 170 187 210 241 270
Torque ∆p = 400 bar T Nm 204 290 356 400 508 572
Weight (approx.) m kg 9.5 13.5 18 18 23 23
Nominal size 107 125 160 180 200 250
Swept volume Vg cm3 106.7 125 160.4 180 200 250
Speed nmax min–1 4000 4000 3600 3600 2750 2500
Inlet flow qV max L/min 427 500 577 648 550 625
Power ∆p = 400 bar Pmax kW 285 333 385 432 367 365 2)
Tightening torque ∆p = 400 bar T Nm 680 796 1016 1144 1272 1393 2)
Weight (approx.) m kg 32 32 45 45 66 73Nominal size 355 500 710 1000
Swept volume Vg cm3 355 500 710 1000
Speed nmax min–1 2240 2000 1600 1600
Inlet flow qV max L/min 795 1000 1136 1600
Power ∆p = 350 bar Pmax kW 464 583 663 933
Torque ∆p = 350 bar T Nm 1978 2785 3955 5570
Weight (approx.) m kg 110 155 322 336
32 45 56 63 80 90
= Preferred product range
29
Fixed displacement motorsType A10FM
Fixed displacement motors
• Nominal pressure 280 bar
• Peak pressure 350 bar
• Standard and plug-in version
• High permissible output speeds
• SAE version
• Series 5
• Open and closed circuit
• Option: Integrated flushing and boost pressure valve
Type A10FM
Nominal sizes 23 to 63
Axial piston swashplate design
Detailed information:RE 91 172
Nominal size 23 28 37 45 63
Swept volume Vg cm3 23.5 28.5 36.7 44.5 63.1
Speed 1) nmax min–1 4900 4700 4200 4000 3400
Inlet flow at nmax qV max L/min 115 134 154 178 215
Power ∆p = 280 bar Pmax kW 43.6 62.5 71.8 83.1 100.1
Torque ∆p = 280 bar T Nm 105 127 163 198 281
Weight (approx.) m kg 12 12 17 17 22
1) At speed nmax it has to be ensured that alow pressure of 18 bar is available.
= Preferred product range
30
Nominal size 22 28 40 56
Swept volume Vg cm3 22 28 40 56
Speed nmax min–1 4250 4250 4000 3600
Inlet flow qV max L/min 93 119 160 202
Power ∆p = 400 bar Pmax kW 62 79 106 134
Torque∆p = 400 bar T Nm 140 178 255 356
Weight (approx.) m kg 11 11 15 21
Nominal size 71 125 250 500
Swept volume Vg cm3 71 125 250 500
Speed nmax min–1 3200 2600 2200 1800
Inlet flow qV max L/min 227 325 550 900
Power ∆p = 350 bar Pmax kW 132 190 321 525
Torque ∆p = 350 bar T Nm 395 696 1391 2783
Weight (approx.) m kg 34 61 120
Fixed displacement motorsType A4FM
Fixed displacement motors
• Nominal pressure:Nominal sizes 22 to 56: 400 barNominal sizes 71 to 500: 350 bar
• Peak pressure:Nominal sizes 22 to 56: 450 barNominal sizes 71 to 500: 400 bar
• Series 3: Nominal sizes 22 to 56, 125 to 500
• Series 1: Nominal size 71
• This compact motor can be used whenever A2FM bent-axismotors cannot be chosen for technical or space reasons, e.g.– Series circuit (high summated pressure)– Mounting of a brake (through-drive option)– Occurrence of rotary vibrations
• Open and closed circuit
Type A4FM
Nominal sizes 22 to 500
Axial piston swashplate design
Detailed information:RE 91 120
Nominal sizes 22 to 56: 2-hole flange
Nominal sizes 71 to 250: 4-hole flange
Nominal size 500: 8-hole flange
= Preferred product range
31
Nominal size, A4FP 32 40 50 63 71 90 112
Swept volume Vg cm3 32 40 50 63 71 90 112
Speed nmax min–1 3700 3700 3200 3200 3200 2600 2600
Inlet flow qV max L/min 118 148 160 202 227 234 291
Power ∆p = 350 bar Pmax kW 69 86 93 118 132 137 170
Torque ∆p = 350 bar T Nm 178 223 278 351 395 501 623
Weight (approx.) m kg 22 22 34 34 34 61 61
Nominal size, A4FP 125 200 224 250 400 450 500
Swept volume Vg cm3 125 200 224 250 400 450 500
Speed nmax min–1 2600 2200 2200 2200 1800 1800 1800
Inlet flow qV max L/min 325 440 493 550 720 810 900
Power ∆p = 350 bar Pmax kW 190 257 287 321 420 473 525
Torque ∆p = 350 bar T Nm 696 1113 1247 1391 2226 2504 2783
Weight (approx.) m kg 61 120 120 120 220 220 220
Plug-in fixed displacement motorsTypes A4FP, 2A4FP, A10FP
Plug-in fixed displacement motors
• Nominal pressure:A4FP, 2A4FP: 350 barA10FP: 280 bar
• Peak pressure:A4FP, 2A4FP: 400 barA10FP: 350 bar
• Series 1
• Open and closed circuit
• For hydrostatic drives, mainly intended for marine applications e.g.– Lateral thrust propeller drives– Cargo pump drives– Fan drives
Types A4FP, 2A4FP
Nominal sizes 32 to 500
Axial piston swashplate design
Detailed information:RE 91 125Type A10FP
Nominal size 18
Axial piston swashplate design
Detailed information:RE 91 175
Nominal size, 2A4FP (Back to Back) 200 224 250 400 450 500 –A10FP – – – – – – 18
Swept volume Vg cm3 2x200 2x224 2x250 2x400 2x450 2x500 18
Speed nmax min–1 2000 2000 2000 1800 1800 1800 4200
Inlet flow qV max L/min 800 896 1000 1440 1620 1800 75,6
Power ∆p = 350 bar Pmax kW 466 522 582 840 946 1050 35,31)
Torque ∆p = 350 bar T Nm 2226 2494 2783 4452 5008 5565 801)
Weight (approx.) m kg 196 196 196 400 400 400 9 1) ∆p = 280 bar
= Preferred product range
32
pSt / I
Vg min Vg max Vg min Vg max
pSt / I
Vg min Vg max
pB
Nominal size A6VM/A6VE 28 55 80 107Swept volume Vg max cm3 28,1 54,8 80 107
Vg 0 cm3 0 0 0 0Speed 1) at Vg max nmax min–1 5550 4450 3900 3550
at Vg 0 nmax min–1 10450 8350 7350 6300Inlet flow at n max qV max L/min 156 244 312 380Power 3) Pmax kW 104 163 208 253Torque 3) T Nm 178 348 510 679Weight (approx.) m kg 16 26 34 47
Nominal size A6VM/A6VE 140 2) 160 200 2)
Swept volume Vg max cm3 140 160 200Vg 0 cm3 0 0 0
Speed 1) at Vg max nmax min–1 3250 3100 2900at Vg 0 nmax min–1 5750 5500 5100
Inlet flow at n max qV max L/min 455 496 580Power 3) Pmax kW 303 331 387Torque 3) T Nm 891 1016 1273Weight (approx.) m kg 60 64 80
Nominal size A6VM 250 5) 355 500 1000Swept volume Vg max cm3 250 355 500 1000
Vg 0 cm3 0 0 0 0Speed 1) at Vg max nmax min–1 2500 2240 2000 1600
at Vg < Vg max nmax min–1 3300 2950 2650 2100Inlet flow at n max qV max L/min 625 795 1000 1600Power 4) Pmax kW 365 464 583 933Torque 4) T Nm 1391 1978 2785 5571Weight (approx.) m kg 90 170 210 430
Variable displacement motorsTypes A6VM, A6VE
Variable displacement motors
• Series 6• Open and closed circuit• Nominal pressure: Nominal sizes 28 bis 200: 400 bar
Nominal sizes 250 to 1000: 350 bar• Peak pressure: Nominal sizes 28 to 200: 450 bar
Nominal sizes 250 to 1000: 400 bar• Motor as standard version (A6VM) or plug-in version (A6VE)• Due to the wide control range, A6VM and A6VE variable
displacement motors meet the requirements for high speed andhigh torque.
• The displacement of these motors can be swivelled to zero, i.e.the adjustment range is from Vg max (swivel angle 25°, 26.5°) toVg min (swivel angle 0°)
• Brake valve can be fitted• Optional with fitted flushing and boost pressure valve• Hydrostatic A6VE plug-in motors are preferably intended for
installation in mechanical gearboxes, e.g. track drive gearboxes
1) When observing qv max2) Only A6VM available3) ∆p = 400 bar at Vg max4) ∆p = 350 bar at Vg max5) Also available as A6VE
Type A6VM, A6VE
Nominal sizes 28 to 1000
Axial tapered piston bent-axis design
Detailed information A6VM:
RE 91 604
A6VE plug-in versionNominal sizes 28 to 250
RE 91 606
HZ / EZHydraulic / electrical two-point adjustment element
HAAutomatic adjustmentelement, high-pressure-related
pB = Operating pressurepSt = Pilot pressureI = Control pressureVg = Swept volume
HD / EPHydr. adjustment element, pilotpressure-related/el. adjustmentelement with prop. solenoid
DAHydraulic adjustmentelement. speed-related
= Preferred product range
33
Vg min Vg max
pSt
Vg min Vg max
pSt
Vg min Vg max
Two-speed motorsType A10VM
Two-speed motors
• Nominal pressure 280 bar
• Peak pressure 350 bar
• Series 5
• Hydraulic or electrical two-point adjustment
• High permissible output speed
• SAE version
• Open and closed circuit
Type A10VM
Nominal sizes 28 to 63
Axial piston swashplate design
Detailed information:RE 91 703
1) For speed nmax a low pressure ofp = 18 bar must be available.
EZ1/EZ2/EZ6/EZ7Electrical two-pointadjustment
DGDirect operatedtwo-point adjustment
Nominal size 28 45 63
Swept volume Vg max cm3 28 45 62
Speed 1) n max min–1 4700 4000 3300
Inlet flow at nmax qV max L/min 132 180 205
Power ∆p = 280 bar P max kW 61 84 95
Torque ∆p = 280 bar Tmax Nm 125 200 276
Weight (approx.) m kg 14 18 26
Energised
De-energised
Vg = DisplacementpSt = Pilot pressure (with HZ)
and actuating pressure(with DG)
HZ/HZ6Hydraulic two-pointadjustment
= Preferred product range
34
Fixed displacement motors
• Short, compact build
• Good low-speed characteristics
• Reversible
• High tightening torques
• High start-up torques
• Great shaft loads permitted
• Low operating noise
• Low pressure loss in positioning control
• Roller-guided pinion
• Few wear parts
Type GMRP
Nominal sizes 50 to 320
Detailed information:RE 14 355
Nominal size 50 80 100 125 160 200 250 320Swept volume Vg max cm3 50.9 78.7 98.9 123.6 158.5197.8 247.2 316.9Start-up tightening torque (70 bar) TStart Nm 31 60 76 96 125 150 206 262Torque T Nm 44 73 90 113 148 184 232 294Speed (at 20 L/min) n max min-1 378 240 190 155 119 96 77 60Operating pressure 1) p max bar 70Positioning time for 180° t s ≤ 0.5Positioning per revolution 1, 2 or 3 1) Continuous operation
Planetary gear motors (positioning motors)Type GMRP
= Preferred product range
35
Radial piston eccentric motorsTypes MR, MRE, MRT, MRTE
Types MR, MRENominal sizes 160 to 8500
Detailed information:RE 15 228
Types MRT, MRTENominal sizes 7100 to 10800
Radial piston eccentric motor with 10 pistons
Detailed information:RE 15 224
Fixed displacement motors
• Closely graduated swept volumes• Very high start-up torques• Smooth running even at very low speeds
(nmin = 0.5 to 1 min–1)• High resistance to thermal shock• Reversible• Suitable for closed-loop control applications• Suitable for fire-resistant fluids• Roller bearings for extremely long service life• Very low operating noise• Version with:
Measurement shaft, hollow shaft, brake
MRNominal size 160 190 250 300 350 450 600
Swept volume Vg cm3 160 192 251 304 349 452 608
Continuous pressure pkonst. bar 250
Power Pmax kW 30 36 48 53 54 75 84
Speed nmax min–1 800 800 750 750 600 600 500
Torque Tmax Nm 720 870 1120 1380 1560 2030 2720
Weight m kg 46 46 50 50 77 77 97
MRNominal size 700 1100 1800 2400 2800 3600
Swept volume Vg cm3 707 1126 1810 2393 2792 3637
Continuous pressure pkonst. bar 250
Power Pmax kW 97 119 157 183 194 198
Speed nmax min–1 500 330 250 220 200 180
Torque Tmax Nm 3170 5100 8240 10650 12650 16350
Weight m kg 97 140 209 325 325 508
MRE MRT MRTENominal size 3100 5400 8500 7100 9000 10800
Swept volume Vg cm3 3104 5401 8525 7100 9005 10802
Continuous pressure pkonst. bar 210 210 210 250 250 210
Power Pmax kW 190 210 260 330 370 310
Speed nmax min–1 200 160 120 150 130 110
Torque Tmax Nm 11700 20600 32500 31300 40000 39300
Weight m kg 320 508 750 920 920 920
MR MRENominal size 4500 6500 7000 500 800 1400 2100
Swept volume Vg cm3 4503 6504 6995 498 804 1369 2091
Continuous pressure pkonst. bar 250 250 250 210 210 210 210
Power Pmax kW 210 250 260 70 93 102 148
Speed nmax min–1 170 130 130 600 450 280 250
Torque Tmax Nm 20250 29450 32000 1880 3020 5160 7850
Weight m kg 508 750 750 77 97 140 209
In the upper pressure and power range, thehousing must be flushed.
= Preferred product range
36
MPU compact motor-pump unitMotor-pump group type ABAPG
Electric motor Built-on pump Type
0.75 kW Variable displacement vane pump PV7..., PV7..A...
Up to 3.6 kW Internal gear pump PGF...
Type MPU with PV7... (pilot operated)
Detailed information: RE 10 515
Type MPU with PV7..A... (directoperated)Detailed information:RE 10 520
Type MPU with PGF
Detailed information:RE 10 213
Compact unit
• Assembly ready for installation
• Low storage cost
• Compact build
Type ABAPG
With pump types A10VSO; PV7; GF3 andPGH
Electric motor BS 132 to 280
Detailed information:RE 51 062
Technical data (pump/motor)
Pump type Internal gear (fixed displacement)
• Displacement Vg max cm3 20 to 125
• Operating pressure pmax bar Up to 315
Pump type Vane (variable displacement)
• Displacement Vg max cm3 30 to 118
• Operating pressure pmax bar Up to 160
Pump type Axial piston (variable displacement)
• Displacement Vg max cm3 18 to 140
• Operating pressure pmax bar Up to 315
Electric motor power P kW 7.5 to 90
Motor/pump group
• Electric motor with support and flange, form B35
• Pump mounted to the motor with pump mounting bracket andcoupling
• Suitable for mounting onto the reservoir or base frame ofseparate installation
• Low operating noise
• For a variety of applications
• Clearly arranged, maintenance-friendly design
• Optionally with fixed or variable displacement pumps
• Combination pumps for multi-circuit systems possible
= Preferred product range
37
HYDRAULIC CYLINDERS
The Bosch-Rexroth cylinders distinguishthemselves due to their high quality andinnovative designs, such as precisely guidedpiston rods in conjunction with state of theart sealing technology, self-adjusting endposition damping or safety bleeding.
Proximity switches and integrated positionmeasuring systems in conjunction withbuilt-on control blocks and high responsevalves make it possible to form completehydraulic axes.
The performance profile
• Mill, tie rod as well as branch and specialcylinders
• Operating pressure up to 4000 bar
• Installation dimensions to ISO, DIN,CETOP, etc.
• Piston diameters Ø 25 to 320 mm (up to1500 mm Hydraudyne)
• Stroke lengths up to 6000 mm (up to24000 mm Hydraudyne)
• Seal systems
• Integrated position measuring systems
• Integrated proximity switches
38
Hydraulic cylinders to ISO
Mill type design
• Mill type design for applications even under extreme operatingconditions
• Easily serviced modular system
• Various mounting styles
• Exchangability due to standardisation
Series CDL1 1) CDM1 2) / H 160 M CDH2 3) / H 250 E
Nominal pressure bar 160 160 250
Piston Ø mm 25 to 200 25 to 200 50 to 320
Piston rod Ø mm 14 to 110 14 to 140 32 to 220
Mounting types 7 9 6
Stroke length mm up to 3000 up to 3000 up to 6000
Stoke speed m/s up to 0.5 up to 0.5 up to 0.5
Detailed information:
• Series CDL1: RD/E/F 17 325
• Series CDM1: RD/E/F 17 328 H160M: AKY 015/10
• Series CDH2: RD/E/F 17 334 H250 E: AKY 015/11
1) Installation dimensions to Bosch Rexroth
2) Installation dimensions to ISO 6020/1,CETOP RP 58 H
3) Installation dimensions to DIN 24 333,ISO 6022 and CETOP RP 73 H
Tie rod design
• Fixing of the head and cap by the tie rod principle
• Easily serviced modular system
• Small installation dimensions
• Various mounting styles
• Exchangability due to standardisation
Detailed information:
• Series CD T3: RD/E/F 17 032 H160CA: AKY 015/9
1) Installation dimensions to DIN 24 554and ISO 6020/2
2) Operating pressure up to 210 barpossible
Series CD T3 1) / H 160 CA
Nominal pressure bar 160 (210 2))
Piston Ø mm 25 to 200
Piston rod Ø mm 12 to 140
Mounting types 14
Stroke length mm up to 3000
Stroke speed m/s up to 0.5
Branch and special cylinders on request! = Preferred product range
39
Hydraulic cylinders
Mill type design
Series C160TH/BH 1) A60/A120H C160SV/SVP/SVU 2)
Nominal pressure bar 160 80/130 160
Piston Ø mm 32 to 160 40 to 80 40 to 80
Piston rod Ø mm 16 to 110 22 to 56 22 to 45
Mounting types 7 12 4
Stroke length mm up to 4500 up to 3000 up to 1500
Stroke speed m/s up to 1 to 1 up to 1
Series CDH1 CDH3
Nominal pressure bar 250 350
Piston Ø mm 40 to 320 40 to 320
Piston rod Ø mm 22 to 220 28 to 220
Mounting types 6 6
Stroke length mm up to 6000 up to 6000
Stroke speed m/s up to 0.5 up to 0.5
Detailed information:
• Series C160TH/TB: AKY 015/3
• Series A60/A120H: 7472 999 315
• Series C160SV/SVP/SVU: BEY 015/2
• Series CDH1: RD/E/F 17331
• Series CDH3: RD/E/F 17337
1) Installation dimensions to ISO 6020/12) With integrated position transducer
40
Tie rod design
Hydraulic cylinders
Series CD70 1) C80H CDW160 2)
Nominal pressure bar 70 80 160
Piston Ø mm 25 to 200 32 to 160 40 to 200
Piston rod Ø mm 12 to 140 18 to 110 28 to 140
Mounting types 16 6 5
Stroke length mm up to 3000 up to 1500 up to 1700
Stroke speed m/s up to 0.5 up to 1 up to 1
Series VBH 3) CD210 1)
Nominal pressure bar 200 210
Piston Ø mm 25 to 125 14 to 200
Piston rod Ø mm 16 to 70 16 to 140
Mounting types 4 16
Stroke length mm up to 160 up to 3000
Stroke speed m/s up to 0.5 up to 0.5
Detailed information:
• Series CD70: RE 17 016
• Series C80H: AKY 015/5
• Series CDW160: RE 17 014
• Series VBH: ATFR 015/16
• Series CD210: RE 17 017
1) Installation dimensions to N.F.P.A and JIC2) With integrated position transducer3) To CNOMO 05.07.65 to 05.07.71
41
SWITCHING VALVES
Subplate mounting directionalvalves
For applications in manufacturing machineswe can offer direct and pilot operatedsubplate mounting directional valves withwet-pin solenoids.
The performance profile
• Direct operated NS 6 and NS 10:Max. operating pressure up to 350 barMax. flow up to 1200 L/min
• Pilot operated NS 10 to NS 32:Max. operating pressure up to 350 barMax. flow up to 1100 L/min
• Porting patterns are internationallystandardised
• Extensive spool symbols and operatingtypes
Pressure, flow and isolatorvalves
In addition to the pressure, flow andisolator valves this product segment alsoincludes accessories such as sub-plates.
The performance profile
• NS 6 to NS 32 as well as as linemounting valves:Max. operating pressure up to 630 bar
• Pressure valvesPressure relief valvesPressure reducing valvesPressure sequence and cut-off valves
• Flow valvesThrottle valvesFlow control valves
• Isolator valvesCheck valvesPilot operated check valves
2-way cartridge valves(logic elements)
2-way cartridge valves are elements thatare designed as a compact block. Thepower component is built into a DIN ISO7368 cavity in a manifold block and is heldin place with a cover.
The performance profile
• NS 16 to NS 160
• Max. operating pressure up to 420 bar
• Directional function
• Pressure function
42
Check valvesTypes S, M-SR
Check valves
• Leak-free closure in one direction
• For threaded connection
• 4 opening pressures:– Without spring– 0.5 bar– 1.5 bar– 3 bar– 5 bar
Type SNominal sizes 6 to 30
Detailed information:RE 20 375
Nominal size 6 8 10
Operating pressure pmax bar 315 315 315
Flow qV max L/min 18 36 60
Nominal size 20 25 30
Operating pressure pmax bar 315 315 315
Flow qV max L/min 250 350 450
Check valve cartridge units
• Leak-free closure in one direction
• 5 opening pressures:– Without spring– 0.2 bar– 0.5 bar– 1.5 bar– 3 bar– 5 bar
• Plug screw with pipe thread ormetric ISO thread
• Installation in manifolds:– As right-angled cartridge valve (version "KE")– As straight cartridge (version "KD")
Type M-SR
Nominal sizes 6 to 30
Detailed information:RE 20 380
Nominal size 6 8 10 15
Operating pressure pmax bar 315 315 315 315
Flow ("KE") qV max L/min – 35 50 120
Flow ("KD") qV max L/min 15 30 50 100
Nominal size 20 25 30
Operating pressure pmax bar 315 315 315
Flow ("KE") qV max L/min 200 300 400
Flow ("KD") qV max L/min 200 300 400 = Preferred product range
Nominal size
43
Check valves of sandwich plate designTypes Z1S, Z2S, Z2SRK
Type Z1S
Nominal sizes 6 and 10
Detailed information:• Nominal size 6 RE 21 533• Nominal size 10 RE 21 536
Check valves of sandwich plate design
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• 8 closing functions
• 3 opening pressures: 0.5; 3; 5 bar
• Optional with– Metal seal: Type Z1S…-3X/V (vpressure fluid > 4 m/s)
– Soft seal: Type Z1S…1-2X/VW4 (vpressure fluid < 4 m/s)
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 40 100
Nominal size 6 10
Operating pressure pmax bar 210 210
Flow qV max L/min 40 80
Type Z2SRK
Nominal sizes 6 and 10
Detailed information:• Nominal size 6 RE 21 543• Nominal size 10 RE 21 549
Pilot operated check valvesof sandwich plate design(210 bar series)
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• For the leak-free closure of two actuator ports
• Opening pressure 1.5 bar
Type Z2SNominal sizes 6 to 22
Detailed information:• Nominal size 6 RE 21 548• Nominal size 10 RE 21 553• Nominal size 16 RE 21 558• Nominal size 22 RE 21 564
Pilot operated check valvesof sandwich plate design
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• For the leak-free closure of one or two actuator ports, even overlonger times at rest
• Opening pressures:– Nominal size 6: 1.5; 3; 7 bar– Nominal size 10: 1.5; 3; 6; 10 bar– Nominal sizes 16 and 22: 3; 5; 7.5; 10 bar
Nominal size 6 10 16 22
Series 6X 3X 5X 5X
Operating pressure pmax bar 315 315 315 315
Flow qV max L/min 60 120 300 450
= Preferred product range
44
Hydraulically pilot operated check valvesTypes SV, SL
Hydraulically pilot operated check valves
• With optional leak-oil port
• Optionally with pre-decompression (nominal sizes 10 to 32 only)
• 4 opening pressures:– Nominal size 6:
1.5; 3; 7 or 10 bar– Nominal size 10:
1.5; 3; 6; or 10 bar– Nominal sizes 16 and 20:
2.5; 5; 7.5 or 10 bar– Nominal sizes 25 and 32:
2.5; 5; 8 or 10 bar
• For subplate mounting ("P"):– Nominal size 6:
Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H, subplates to RE 45 052
– Nominal sizes 10 to 32:Porting pattern to DIN 24 340 form D, ISO 5781 andCETOP–RP 121 H, subplates to RE 45 062
• For threaded connection ("G") (nominal size 10 to 32 only)
Types SV, SL
Nominal sizes 6 to 32
Detailed information:• Nominal size 6
RE 21 460• Nominal sizes 10 to 32
RE 21 468
• Nominal sizes 52 to 150on enquiry
Nominal size 6 10 16
Series 6X 4X 4X
Operating pressure pmax bar 315 315 315
Pilot pressure pSt bar 5 to 315 5 to 315 5 to 315
Flow ("G") qV max L/min – 150 350
Flow ("P") qV max L/min 60 150 –
Nominal size 20 25 32
Series 4X 4X 4X
Operating pressure pmax bar 315 315 315
Pilot pressure pSt bar 5 to 315 5 to 315 5 to 315
Flow ("G") qV max L/min 350 550 550
Flow ("P") qV max L/min 350 – 550
Nominal size 52 to 150
Series 1X
Operating pressure pmax bar 315
Pilot pressure pSt bar 0,6 to 315
Flow qV max L/min 700 to 6400
= Preferred product range
45
Check valvesValve cover
Check valves ISO 7368
• Leak-free closure in one direction
• 4 opening pressures:– 0.3 bar– 1.0 bar– 4.0 bar– 10.0 bar
• For fitting into manifold blocks
Detailed information:AKY 011/1
* At ∆p 8 bar
Valve cover
• For check valves
Detailed information:AKY 011/1
Nominal size 16 25 32
Operating pressure pmax bar 315 315 315
Flow qV max* L/min 370 680 1100
Nominal size 40 50
Operating pressure pmax bar 315 315
Flow qV max* L/min 1600 2300
Nominal size 16 25 32
Operating pressure pmax bar 315 315 315
Weight m kg 0.7 1.5 3.0
Nominal size 40 50
Operating pressure pmax bar 315 315
Weight m kg 5.5 8.1
46
Check valves of sandwich plate designBypass check valvesIsolator valves
Pilot operated check valvesof sandwich plate design
• Porting pattern to ISO 4401
Detailed information:AKY 010/5
Detailed information:AKY 007/3, page 37
Isolator valves of sandwich plate design
• Spool and poppet versions
• Porting pattern to ISO 4401
Detailed information:AKY 010/5
Nominal size 6 10 16 25
Operating pressure pmax bar 315 315 250 250
Flow qV max L/min 40/60 120 200 250
Bypass check valves
• For throttle and flow control valves
• Porting pattern to ISO 4401
• A → B closed, P and T closed
Nominal size 6
Operating pressure pmax bar 315
Flow qV max L/min 60
Nominal size 6 10
Operating pressure pmax bar 250 250
Flow qV max L/min 50 100 = Preferred product range
47
Nominal size 6 10 25
Operating pressure pmax bar 315 315 315
Pilot pressure pSt bar 3 to 315 - -
Direct operated pSt bar - - px = 0.75 pB + 0.54 pA1)
px = 0.75 pB + 0.33 pA2)
Pilot operated pSt bar - px = 0.07 pB + 0.93 pA1) -
px = 0.07 pB + 0.07 pA2)
Flow qV max L/min 60 47 90
Hydraulic pilot operated check valves
• With optional drain connection• Porting pattern to ISO 5781
Hydraulic pilot operated check valves
Detailed information:AKY 007/31) Internal drain2) External drain
48
Pre-fill valvesTypes ZSF and ZSFW, Type SF
Types ZSF, ZSFW
Detailed information:RE 20 478
Nominal size 32 to 160
Operating pressure pmax bar 350
Pre-fill valves
• Hydraulic pilot operated check valve of sandwich plate design
– For flange connections
– For line mounting
• Solenoid operated decompression via built-on directional valve
Type SF
Detailed information:RE 20 482
Nominal size 125 to 400
Operating pressure pmax bar 350
Pre-fill valves
• Hydraulic pilot operated check valve
– For flange connections
– For reservoir mounting
= Preferred product range
Type SFA
Detailed information:RE 20 485
Nominal size 32 to 80
Operating pressure pmax bar 350
Pre-fill valves
• Hydraulic pilot operated check valve
– For threaded connections (NS 32)
– For flange connections (from NS 40)
• For mounting directly on the work cylinder
• With or without decompression
• Integrated high pressure connection
49
Directional poppet valves, direct operatedTypes SMM, SH, SP, SEW, SED
Types SEW, SED
Nominal sizes 6 and 10
Detailed information:• Nominal size 6
1) RE 22 0582) RE 22 049
• Nominal size 103) RE 22 0754) RE 22 045
Nominal size 6
Version SEW 1) SED 2)
Operating pressure pmax bar 420/630 350
Flow qV max L/min 25 25
Directional poppet valves, direct operated
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Leak-free isolation of closed port
• Solenoids with detachable coil
• The pressure-tight chamber needs not to be opened forchanging the coil 2); 4)
• Switching is ensured even when under pressure for long periodsof time
Nominal size 10
Version SEW 3) SED 4)
Operating pressure pmax bar 420/630 350
Flow qV max L/min 40 40
= Preferred product range
50
Directional poppet valves type KSEDirectional spool valves type KKE
Build size 1
Version 2/2 1); 2) 3/2 3)
Operating pressure pmax bar 350 350
Flow qVmax L/min 20 12
Directional poppet valves, direct operated
• Direct operated directional poppet valve with solenoid operation
• Closed port is leak-free
• Safe switching even after long periods of time
• Wet-pin DC solenoids
• Coil can be rotated
• With protected hand override
• Leak-free on both sides 2)
Type KSE
Build size 1
Detailed information:RE 18 136-02 1) and RE 18 136-03 3)
Build size 1
Version 3/2 1) 4/2 2)
Operating pressure pmax bar 350 350
Flow qVmax L/min 60 50
Directional spool valves, direct operated• Direct operated directional spool valve with solenoid operation
• Valves can pass flow in both directions
• Wet-pin DC solenoids
• Coil can be rotated
• With protected hand override
Type KKE
Build size 1
Detailed information:RE 18 136-04 1) and RE 18 136-05 2)
= Preferred product range
51
Directional spool valves, direct operatedTypes WH., WP, WN, H-WH, WM., H-WMM
Types WH and WHD, hydraulically operated
Types WN and WP, pneumatically operatedNominal sizes 6 to 32
Detailed information:• Nominal size 6, types WH, WP
RE 22 282• Nominal size 10, types WHD, WP, WN
1) RE 22 331• Nominal sizes 10 to 32, types H-WH, WH
2) RE 24 751
Nominal size 6 10 1) 10 2)
Type WH, WP WHD, WP, WN H-WH, WH
Operaing pressure pmax bar 315 315 350/280
Flow qV max L/min 60 120 160
Nominal size 16 22 25 32
Type H-WH, WH
Operaing pressure pmax bar 350/280 350/280 350/280 350/280
Flow qV max L/min 300 450 650 1100
Nominal size 4 6 10
Type WMM…K 3) 3)
Operating pressure pmax bar 160 315 315
Flow qV max L/min 25 60 1203) WMM, WMR, WMU, WMD, WMDA
Type WMM, lever operated
Types WMR, WMU, roller operated
Type WMD, rotary knob operatedNominal sizes 4 to 22
Detailed information:• Nominal size 4 RE 23 140 ("K")
• Nominal size 6 RE 22 280RE 22 284
• Nominal size 10 RE 22 312RE 22 331
• Nominal sizes 16 and 22 RE 22 371
• Nominal sizes 32 RE 23 778
Directional spool valves, direct operated
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Available as cartridge valve (Re 23 140, version "K")
• Position monitoring by means of– inductive limit switch or– mechanical limit switch
Directional spool valves, direct operated
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Stroke adjustment element, optional 2)
• Position monitoring by means of inductive limit switch
= Preferred product range
Nominal size 16 22 32
Type H-WMM H-WMM H-WMM
Operating pressure pmax bar 350 350 350
Flow qV max L/min 300 450 1100
52
Directional spool valves, direct operatedType WE
Type WE
Nominal sizes 4 to 10
Detailed information:• Nominal size 4
RE 23 160 ("P")
• Nominal size 6RE 23 163 1)
RE 23 178 2)
RE 23 183 3)
RE 23 178-00 4)
• Nominal size 10RE 23 183 3)
RE 23 327 5)
RE 23 351 6)
Nominal size 4
Version "P"
Operating pressure pmax bar 210
Flow qV max L/min 25
Directional spool valves, direct operated,with solenoid actuation
• Wet-pin DC or AC solenoids
• Solenoids with detachable coil
• For subplate mounting ("P"):Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Electrical connection as individual or central connection
• Inductive position monitor, optional (RE 24 830)
• Damped switching characteristics 3)
Nominal size 6
Version 1) 2) 3) 4)
Operating pressure pmax bar 315 350 350 315
Flow qV max L/min 60 80 60 60
Nominal size 10
Version 3) 5) 6)
Operating pressure pmax bar 315 315 315
Flow qV max L/min 100 120 120
1) Standard valve, NS 6 (DC solenoid only)2) Heavy duty valve3) Soft switching valve4) Reduced electrical power consumption5) Standard valve, NS 106) 5-chamber version (DC solenoid only)
= Preferred product range
53
Directional spool valves, pilot operatedType WEH
Type WEHNominal sizes 10 to102Detailed information:
Nominal sizes 10 to 32RE 24 751
Nominal sizes 52 to 102on enquiry
RE 24 830
Nominal size 10
Type 4WEH H-4WEH
Operating pressure pmax bar 280 350
Flow qV max L/min 160 160
Directional spool valves, pilot operated,with electro-hydraulic actuation
• Wet-pin DC or AC solenoids
• Spring and/or pressure return of the main spool to the initialposition
• Spring centering (NS 10 and 22)
• Spring or pressure centering (NS 16, 25 and 32)
• Manual override, optional
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Electrical connection as individual connection or centralconnection
• Switching time adjustment element, optional
• Stroke limiter at the main spool, optional (RE 24 830)
• Stroke limiter and/or end position control (NS 16, 22, 25 and32), optional (RE 24 830)
• Position monitoring by means of inductive limit switch (RE 24 830)
• Preload valve in the P-channel of the main valve for NS 16, 22,25 and 32
Nominal size 16
Type 4WEH H-4WEH
Operating pressure pmax bar 280 350
Flow qV max L/min 300 300
Nominal size 22
Type 4WEH H-4WEH
Operating pressure pmax bar 280 350
Flow qV max L/min 450 450
Nominal size 25 32 32
Type H4-WEH 4WEH H-4WEH
Operating pressure pmax bar 350 280 350
Flow qV max L/min 650 1100 1100
= Preferred product range
Nominal size 52 62 82 102
Type H-4WEH H-4WEH H-4WEH H-4WEH
Operating pressure pmax bar 350 350 350 350
Flow qV max L/min 2000 3000 4500 7000
54
a ba b
a b b a
Rexroth Bosch
Directional spool valves, direct operated
Directional spool valves, direct operated
• Porting pattern to DIN 24 340, ISO 4401 andCETOP R 35 H
• Optional stroke limitation
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 90 130
Pilot pressure Hydraulic barPneumatic bar
20 to 210 14 to 2502 to 10 2.5 to 10
Nominal size 10 16 25
Operating pressure pmax bar 350/280 350/280 350/280
Flow qV max L/min 160 300 700
Directional spool valves, direct operated
• Porting pattern to DIN 24 340, ISO 4401 andCETOP R 35 H
Lever operation
Roller operation
Detailed information:NS 6 AKY 006/6NS 10 AKY 006/7NS 10, 16, 25 AKY 006/5
The spool movement when operating thelever is opposite with Rexroth whencompared to Bosch.
Hydraulic operation
Pneumatic operation
Detailed information:NS 6 AKY 006/6NS 10 AKY 006/7NS 10, 16, 25 AKY 006/5
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 90 130
• Rotation point= Preferred product range
55
Directional spool valves, direct operated
Directional spool valves, direct operated,with solenoid operation
• Wet-pin AC or DC solenoids
• Pressure tight solenoid with removable coil
• Porting pattern to DIN 24 340 form A and ISO 4401
• Various types of electrical connections
Nominal size 6
Detailed information:
1)AC or DC solenoidsAKY 006/6
2)Series EBEY 006/14
3)Solenoids and explosion protectionBEY 006/15
4) Reduced electrical power consumption(8 Watt)BEY 006/16
5)With M12 central plugBEY 006/17
6)With M12 connectionBEY 006/18
7)Active plug for switching valvesBEY 006/19
8)Soft switchingBEY 006/20
Nominal size 10Detailed information:
1)AC or DC solenoidsAKY 006/7
2)With M12 connectionBEY 006/21
Nominal size 10
Version 1) 2)
Operating pressure pmax bar 315 315
Flow qV max L/min 130 130
Nominal size 6
Version 5) 6) 7) 8)
Operating pressure pmax bar 250 315 315 315
Flow qV max L/min 40 90 90 50
Nominal size 6
Version 1) 2) 3) 4)
Operating pressure pmax bar 315 250 210 250
Flow qV max L/min 90 50 90 40
= Preferred product range
56
Directional spool valves, pilot operated,with electro-hydraulic operation
• Wet-pin AC or DC solenoids
• Spring centered main spool
• NS 6 pilot stage
• Porting pattern to DIN 24 340 form A and ISO 4401
• Various types of electrical connections
• Switching time adjustment, optional
• Pilot oil supply, optional
• Main spool stroke limitation
• Pre-load valve in the P port of the main valve for NS 16, 25
Nominal sizes 10, 16, 25Detailed information:AKY 006/5
Directional spool valves, pilot operated
Nominal size 10 16 25
Operating pressure pmax bar 350 350 350
Flow qV max L/min 160 300 700
57
Pressure relief valvesTypes DBD (direct operated), DB, DBW (pilot operated)
Type DBDNominal sizes 6 to 30
Detailed information:RE 25 402
Pressure relief valves, direct operated
• For subplate mounting ("P")
• For threaded connection ("G")
• As cartridge valve ("K")
• Type-tested
• 3 optional pressure adjustment elements:– Headless pin with hexagon socket and protective cap– Rotary knob / hand wheel– Lockable rotary knob
Nominal size 6 8 10 15Version "P, G, K" "G" "P, G, K" "G"Operating pressure pmax bar 400 400 630 400Flow qV max L/min 50 120 120 250
Nominal size 20 25 30Version "P, G, K" "G" "P, G, K"Operating pressure pmax bar 400 315 315Flow qV max L/min 250 330 330
Types DB, DBW
Nominal sizes 6 to 30
Detailed information:• Nominal sizes 6 and 10
Series 4X (only "K") 3) RE 25 731
• Nominal sizes 10 to 30Series 5X 1) RE 25 802
• Nominal sizes 10, 15, 20Series 4X 2) RE 25 818
• Nominal size 20Series 1X (only "K") 2) RE 25 818
Pressure relief valves, pilot operated• For subplate mounting ("P"):
Porting pattern to DIN 24 340 form E, ISO 6264 and CETOP–RP121 H
• For block installation ("C")• For threaded connection ("G")• As cartridge valve ("K")• Solenoid operated unloading via built-on directional spool valve
or directional poppet valve• Switching shock dampening, optional 1) (type DBW. only)• 4 pressure adjustment elements, optional:
– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
Nominal size 6 10 1) 10 2) 15 1) 15 2)
Operating pressure pmax bar 315 350 350 350 350Flow ("P") qV max L/min – 250 200 – –Flow ("G") qV max L/min – 250 150 500 300Flow ("C") qV max L/min – 215 – – –Flow ("K") qV max L/min 60 3) 100 3) 150 – –
Nominal size 20 1) 20 2) 25 1) 30 1)
Operating pressure pmax bar 350 350 350 350Flow ("P") qV max L/min 500 400 – 650Flow ("G") qV max L/min 500 300 500 650Flow ("C") qV max L/min – – – 650Flow ("K") qV max L/min 300 – – – = Preferred product range
58
Pressure relief valves of sandwich plate design, pilot operatedTypes ZDB, Z2DB, ZDBK, Z2DBK
Types ZDB and Z2DB
Nominal sizes 6 and 10
Detailed information:• Nominal size 6
RE 25 751
• Nominal size 10RE 25 761
Pressure relief valvesof sandwich plate design, pilot operated
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• 4 pressure stages: 50, 100, 200, 315 bar
• 5 pressure relief functions:A – T,P – T,B – T,A – T and B – T,A – B and B – A
• 4 adjustment elements:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob and scale– Rotary knob with scale
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 60 100
Types ZDBK and Z2DBKNominal sizes 6 and 10
Detailed information:• Nominal size 6
RE 25 754
• Nominal size 10RE 25 764
Pressure relief valvesof sandwich plate design, pilot operated
(210 bar series)
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• 5 pressure relief functions:A – T,P – T,B – T,A – T and B – T,A – B and B – A
• 3 pressure stages: 50, 100, 210 bar
Nominal size 6 10
Operating pressure pmax bar 210 210
Flow qV max L/min 40 80
= Preferred product range
59
Pressure relief valves, direct operatedPressure relief valves, pilot operated
Pressure relief valves, direct operated
• For subplate mounting ("P")
• For threaded connections ("G")
• As a cartridge valve ("K")
• With design testing
• Optional adjustment elements– Grup screw with slot and protective cap– Grub screw with internal hexagon– Rotary knob / hand wheel– Lockable rotary knob
Detailed information:AKY 007/3 Page 6 to 15
*Vertical and horizontal versions
Detailed information:AKY 007/3
Pressure relief valves, pilot operated• For subplate mounting ("P")• Optional adjustment elements
– Grub screw with internal hexagon and protective cap– Rotary knob / hand wheel– Lockable rotary knob
Nominal size 6 10 25Operating pressure pmax bar 315 315 315Flow qV max L/min 60 300 400
= Preferred product range
Nominal size 6 10
Version "K; G" "K; G"
Operating pressure pmax bar 350 350
Flow qV max L/min 60 120
Nominal size 6 10
Version "P"* "P"
Operating pressure pmax bar 315 300
Flow qV max L/min 60 120
60
Pressure relief valves of sandwich plate design, direct operatedPressure relief valves of sandwich plate design, pilot operated
Detailed information:AKY 010/5Page 6 to 10 (NS 6)Page 17 to 21 (NS 10)
Pressure relief valvesof sandwich plate design, direct operated
• Porting pattern to ISO 4401
• 3 pressure stages: 80, 160, 315 bar
• 5 pressure relief functions:A – T,P – T,B – T,A – T and B – T,A – B and B – A
• Adjustment elements:– Grub screw with internal hexagon– Rotary knob with scale– Lockable rotary knob with scale
Detailed information:AKY 010/5
Pressure relief valvesof sandwich plate design, pilot operated
• Porting pattern to ISO 4401
• 2 pressure stages: 80, 160 bar
• NS 6: 2 pressure relief functions:P - TA - B and B - ANS 10: 1 pressure relief function: P - T
• Adjustment elements:– Grub screw with internal hexagon– Rotary knob with scale– Lockable rotary knob with scale
Nominal size 6 10
Operating pressure pmax bar 250/315 315
Flow qV max L/min 50/60 120
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 60 90/120
= Preferred product range
61
Pump safety blocks, pilot operatedTypes DBA, DBAW, DBAE
Types DBA, DBAW, DBAE
Nomianl sizes 16 to 32
Detailed information:RE 25 890
Pump safety blicks, pilot operated
• For direct mounting onto the SAE pressure port of the pump
• Zero pressure start-up and circulation of the pump
• Solenoid operate unloading via a built-on directional spool valveor directional poppet valve
• Electrical monitoring of the set pressure
• Proportional pressure limitation and unloading using external orintegral control electronics
Nominal size 16 25 32Operating pressure pmax bar 350 350 350Flow qV max L/min 300 400 400
Nominal size 32 40
Operating pressure pmax bar 420 420
Flow (without check valve) qV max L/min 600 650
Flow (with check valve) qV max L/min 350 450
Types DBA, DBAW
Nominal sizes 32 und 40
Detailed information:RE 25 880
Pump safety blocks, pilot operated
• For direct mounting onto the SAE pressure port of the pump
• Zero pressure start-up and circulation of the pump
• With integrated check valve
• Solenoid operated unloading via built-on directional spool valveor directional poppet valve
• Switching shock dampening, optional (type DBAW only)
• 4 pressure adjustment elements, optional:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
= Preferred product range
62
Pressure reducing valves of sandwich plate designTypes ZDR.D (direct operated) and ZDR10V, ZDRK.V (pilot operated)
Pressure reducing valvesof sandwich plate design, direct operated
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Pressure reduction in channels A, B or P• 4 pressure stages: 25, 75, 150, 210 bar• 4 adjustment elements:
– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
• Check valve, optional
Nominal size 6 10
Series 4X 5X
Operating pressure pmax bar 210 210
Flow qV max L/min 50 80
Nominal size 6 10
Operating pressure pmax bar 210 210
Flow qV max L/min 40 80
Type ZDRK.V
Nominal sizes 6 and 10
Detailed information:• Nominal size 6 RE 26 572• Nominal size 10 RE 26 864
Pressure reducing valvesof sandwich plate design, pilot operated
(210 bar series)
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• Pressure reduction in channels A, B or P(with NS 6, channel P only)
• 3 pressure stages: 50, 100, 210 bar
• Pressure gauge connection
Type ZDR.D
Nominal sizes 6 and 10
Detailed information:• Nominal size 6 RE 26 570• Nominal size 10 RE 26 585
Type ZDR10V
Nominal size 10
Detailed information:RE 26 861
Pressure reducing valvesof sandwich plate design, pilot operated• Porting pattern to DIN 24 340 form A, ISO 4401 and CETOP–RP 121 H
• Pressure reducing in channels A, B or P
• 4 pressure stages: 50, 100, 200, 315 bar
• 4 adjustment elements:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
• Check valve, optional
Nominal size 10
Operating pressure pmax bar 315
Flow qV max L/min 100
= Preferred product range
63
Pressure reducing valvesTypes DR.D (direct operated) and DR (pilot operated)
Type DR.D
Nominal sizes 6 and 10
Detailed information:• Nominal size 6, series 5X
RE 26 564
• Nominal size 10, series 4XRE 26 580
Pressure reducing valves, direct operated
• Porting pattern – nominal size 6 toDIN 24 340 form A, ISO 4401 and CETOP–RP 121 H
• Porting pattern – nominal size 10 toDIN 24 340 form D, ISO 5781 and CETOP–RP 121 H
• 5 pressure stages
• 4 pressure adjustment elements, optional:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
• Check valve, optional
Nominal size 6 10
Secondary pressure, adjustable pmax bar 315 210
Flow qV max L/min 60 80
Nominal size 20 3) 20 4) 25 3) 30 3)
Secondary pressure 1) pmax bar 350 315 350 350
Flow ("P") qV max L/min 300 160 – 400
Flow ("G") qV max L/min 300 160 400 400
Flow ("C") qV max L/min – – – 400
Flow ("K") qV max L/min – 160 – –
Type DRNominal sizes 10 to 30
Detailed information:• Nominal size 10, series 3X (only "K")
5) RE 26 850
• Nominal sizes 10 to 30, series 5X3) RE 26 892
• Nominal sizes 10; 15; 20, series 4X4) RE 26 893
Pressure reducing valves, pilot operated• For subplate mounting ("P"):
Porting pattern to DIN 24 340 form D, ISO 5781 andCETOP–RP 121 H
• For block installation ("C")• For threaded connection ("G")• As cartridge valve ("K")• 4 pressure stages• 4 pressure adjustment elements, optional:
– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
• Check valve, optional (for version "P" only)
Nominal size 10 3;5) 10 4) 15 3) 15 4)
Secondary pressure 1) pmax bar 350 2) 315 350 350
Flow ("P") qV max L/min 150 80 – –
Flow ("G") qV max L/min 150 80 300 160
Flow ("K") qV max L/min 100 5) 100 5) – –
1) Adjustable2) For version "K": pmax = 315 bar
= Preferred product range
64
Pressure reducing valves of sandwich plate design, direct operatedPressure reducing valves of sandwich plate design, pilot operated
Detailed information:AKY 010/5
Pressure reducing valvesof sandwich plate design, direct operated
• Porting pattern to ISO 4401
• 4 pressure stages: 30, 80, 160, 250 bar
• 2 pressure reducing functionsP - T and A - T
• Adjustment elements– Grub screw with internal hexagon– Rotary knob with scale– Lockable rotary knob with scale
Nominal size 6 10
Operating pressure pmax bar 210/315 250
Flow qV max L/min 60 50
Detailed information:AKY 010/5
Pressure reducing valvesof sandwich plate design, pilot operated
• Porting pattern to ISO 4401
• 4 pressure stages: 30, 80, 160, 315 bar
• 3 pressure reducing functionsP - TA - T and B - T
• Adjustment elements– Grub screw with internal hexagon– Lockable rotary knob with scale
Nominal size 10
Operating pressure pmax bar 200/315
Flow qV max L/min 120
65
Pressure reducing valves, direct operatedPressure reducing valves, pilot operated
Detailed information:AKY 007/3
Pressure reducing valves, direct operated
• Porting pattern to ISO 5781 and DIN 24 340 form P
• 4 pressure stages
• Adjustment elements– Grub screw with internal hexagon– Rotary knob with scale– Lockable rotary knob with scale
• Optional check valve
Detailed information:AKY 007/3
Pressure reducing valves, pilot operated
• Porting pattern to ISO 5781 and DIN 24 340 form P
• 3 pressure stages
• Adjustment elements– Hand wheel– Rotary knob with scale– Lockable rotary knob with scale
• Optional check valve
Nominal size 6 10
Secondary pressure, adjustable pmax bar 210/315 315
Flow qV max L/min 60 300
Nominal size 10 25
Secondary pressure pmax bar 315 315
Flow qV max L/min 300 400
66
Pressure sequencing valvesTypes DZ.D (direct operated) and DZ (pilot operated)
Type DZ.D
Nominal sizes 5, 6, 10
Detailed information:• Nominal size 5, series 1X
RE 26 055
• Nominal size 6, series 5X1) RE 26 0762) RE 26 080 (load-dependent counter-
balance valve)
• Nominal size 10, series 4XRE 26 099
Pressure sequencing valves, direct operated
• Porting pattern – nominal size 6 toDIN 24 340 form A, ISO 4401 and CETOP–RP 121 H
• Porting pattern – nominal size 10 toDIN 24 340 form D, ISO 5781 and CETOP–RP 121 H
• 4 pressure adjustment elements optional:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
• Check valve, optional
Nominal size 5 6 1) 6 2) 10
Sequencing pressure pmax bar 315 210 200 210
Flow qV max L/min 15 60 40 80
Type DZNominal sizes 10, 20, 30
Detailed information:RE 26 391
Pressure sequencing valves, pilot operated
• For subplate mounting ("P"):Porting pattern to DIN 24 340 form D, ISO 5781 andCETOP–RP 121 H
• For block installation ("C")
• Suitable for use as pre-load, sequencing and by-pass valve
• 4 pressure adjustment elements, optional:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
• Check valve, optional
Nominal size 10 20 30
Version "P" "P" "P", "C"
Sequencing pressure pmax bar 315 315 315
Flow qV max L/min 200 400 600
= Preferred product range
67
Pressure cut-off valvesType DA (pilot operated)
Pressure cut-off valves, pilot operated
• For subplate mounting ("P"):Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• For block installation ("C")
• As cartridge valve ("K")
• Solenoid operated unloading via built-on directional valve(NS 10, 20, 30)
• 4 pressure adjustment elements, optional:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
Type DA
Nominal sizes 6 to 30
Detailed information:• Nominal size 6, series 4X
RE 26 404
• Nominal sizes 10; 20; 30, series 5XRE 26 411
1) Switching pressure differential 10 %2) Switching pressure differential 17 %3) At qV max = 100 %
Nominal size 6 10 25 30
Version "P", "K" "P" "P" "P", "C"
Cut-off pressure pmax bar 315 315 315 315
Flow 1) qV max L/min 30 3) 40 80 120
Flow 2) qV max L/min – 60 120 240
= Preferred product range
68
Pressure sequence valves, pilot operatedPressure cut-off valves, pilot operated
Detailed information:AKY 007/3
Pressure sequence valves, pilot operated
• Porting pattern to ISO 5781-06-07DIN 24 340-D10-1, form P
• Optional check valve
• Internal or external drain
• Adjustment element– Hand wheel
Detailed information:AKY 007/3
Pressure cut-off valves, pilot operated• Porting pattern to ISO 5781-06-07
DIN 24 340-D10-1, form P• Optional check valve• Internal or external drain• Adjustment element
– Hand wheel
Nominal size 10 25
Sequence pressure pmax bar 315 315
Flow qV max L/min 300 400
Nominal size 10 25
Cut-off pressure pmax bar 315 315
Flow qV max L/min 300 400
69
Double throttle check valves of sandwich plate designTypes Z2FS and Z2FSK
Double throttle check valvesof sandwich plate design
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• For limiting the main or pilot flow of one or two actuators
• Meter-in or meter-out throttling
• 4 adjustment elements:– Rotary knob– Sleeve with hexagon and protective cap– Lockable rotary knob with scale– Rotary knob with scale
Nominal size 6 10 16 22
Series 4X 2X 3X 3X
Operating pressure pmax bar 315 315 350 350
Flow qV max L/min 80 160 250 360
Type Z2FS
Nominal sizes 6 to 22
Detailed information:• Nominal size 6 RE 27 506• Nominal size 10 RE 27 518• Nominal size 16 RE 27 526• Nominal size 22 RE 27 536
Nominal size 6 10
Operating pressure pmax bar 210 210
Flow qV max L/min 40 80
Type Z2FSK
Nominal sizes 6 and 10
Detailed information:• Nominal size 6 RE 27 510• Nominal size 10 RE 27 524
Double throttle check valvesof sandwich plate design
(210 bar series)• Porting pattern to DIN 24 340 form A, ISO 4401 and
CETOP–RP 121 H
• For limiting the flow of two actuator ports
• Meter-in or meter-out throttling
= Preferred product range
70
Throttle valves, throttle check valvesTypes MG, MK, F
Throttle valves, throttle check valves
• For in-line installation
• Pressure and viscosity-dependent
• Type MG:Throttling in both directions of flow
• Type MK:Throttling in only one direction of flow, free-flow in the oppositedirection (opening pressure 0.5 bar)
• Type F (needle type throttle valves):Throttling in both directions of flow
Nominal size 6 8 10 15
Operating pressure pmax bar 315 315 315 315
Flow qV max L/min 15 30 50 120
Nominal size 20 25 30
Operating pressure pmax bar 315 315 315
Flow qV max L/min 200 300 400
Nominal size 52 62 82 102
Operating pressure pmax bar 315 315 315 315
Flow qV max L/min 700 1100 1800 3000
Type MG and MK
Nominal sizes 6 bis 102
Detailed information:• Nominal sizes 6 to 30
RE 27 219• Nominal sizes 52 to 102
on enquiry
Type F
Nominal sizes 5 and 10
Detailed information:RE 27 761
= Preferred product range
Nominal size 5 10
Operating pressure pmax bar 210 210
Flow qV max L/min 20 50
71
2-way flow control valves• For subplate mounting:
– Porting pattern – Nominal size 6 toDIN 24 340 form A, ISO 4401 and CETOP–RP 121 H
– Porting pattern – Nominal sizes 10 and 16 toDIN 24 340 form G, ISO 6263 and CETOP–RP 121 H
• Flow control in both directions by means of rectifier sandwichplate (see below, type Z4S)
• Stroke limiter of the rack-and-pinion drive that can be adjustedon both ends (types 2FRH and 2FRW)
• With actual value potentiometer for continuous monitoring ofthe throttle orifice position, optional (types 2FRH and 2FRW)
• With external closure of the pressure compensator, optional (NS 6)• Check valve, optional (NS 6)• Pressure compensator stroke limiter for reducing the start-up
jump, optional (NS 10 and 16)
Nominal size 6 10 16
Type 2FRM 2FRM, 2FRH, 2FRW
Series 3X 3X 3X
Operating pressure pmax bar 315 1) 315 315
Pilot pressure pSt bar – 315 315
Flow qV max L/min 32 50 160
Type 2FRM, manual operation
Type 2FRH, hydraulic operationType 2FRW, electro-hydraulicoperation
Nominal sizes 6 to 16
Detailed information:• Nominal size 6
RE 28 163• Nominal sizes 10 and 16
RE 28 389
2-way flow control valves and rectifier sandwich platesTypes 2FRM, 2FRH, 2FRW and Z4S
Nominal size 6 10 16
Series 1X 3X 2X
Operating pressure pmax bar 210 315 315
Flow qV max L/min 32 50 160
Rectifier sandwich plates (Graetz circuit)for combination with flow control valves
• For ensuring a recified flow through a built-on flow control valve
• Can be used for supply and return flow
Type Z4S
Nominal sizes 5 to 16
Detailed information:• Nominal size 6
RE 28 163• Nominal sizes 10 and 16
RE 28 389
1) With rectifier sandwich plateup to 210 bar
= Preferred product range
72
2-way flow control valvesof sandwich plate design
• Porting pattern to DIN 24 340 form A, ISO 4401 andCETOP–RP 121 H
• With flow control in channels A, B, A and B or T (P)
Type Z2FRMNominal size 6
Detailed information:RE 28 164
2-way flow control valvesTypes 2FRM.K, Z2FRM
2-way flow control valves
• As cartridge valve ("K")
• With integrated check valve
Type 2FRM.K
Nominal sizes 6 and 10
Detailed information:RE 28 155
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 32 60
Nominal size 6
Operating pressure pmax bar 315
Flow qV max L/min 32
= Preferred product range
73
Double throttle check valve of sandwich plate designThrottle, throttle check valves, subplate mounting
Double throttle check valveof sandwich plate design
• Porting pattern to ISO 4401
Detailed information:AKY 010/5
Detailed information:AKY 007/3
Throttle, throttle check valvesfor subplate mounting
• Porting pattern to ISO 5781
• For limiting the main or pilot flow toone or two actuators
• Meter-in or meter-out throttling
• Adjustment element– Grub screw with internal hexagon
• For limiting the main or pilot flow toone or two actuators
• Meter-in or meter-out throttling (interchangable)
• Adjustment elements– Grub screw with internal hexagon– Grub screw with four flats
Nominal size 6
Operating pressure pmax bar 315
Flow qV max L/min 60
Nominal size 6 10 16 25
Operating pressure pmax bar 315/250 315 315 315
Flow qV max L/min 60/50 120 200 250
= Preferred product range
74
2-way flow control valves
Detailed information:AKY 007/3
2-way flow control valves• For subplate mounting• Flow control in one direction• Check valve, optional• Adjustment elements
– Rotary knob with scale– Lockable rotary knob with scale
Nominal size 6 10 16
Operating pressure pmax bar 315 250 250
Pilot pressure pSt min bar 5/8.5 6 7
Flow qV max L/min 18 60 130
75
2-way cartridge valves with directional functionTypes LC..A, LC..B, LFA
2-way cartridge valves with directional function
• Valve poppet with or without damping nose
• 4 different springs/opening pressures
• 4 stroke limiters
• Control cover with integrated poppet or shuttle valve
• Control cover for mounting directional poppet valves andintegrated shuttle valve, optional
• Control cover for mounting directional spool valves andintegrated shuttle valve, optional
• Power part as cartridge valve in stadardised mounting cavity(DIN 24 342, however, only up to nominal size 100), closed bymeans of a control cover
• Area ratio:– Type LC..A: 2:1– Type LC..B: 14,3:1
Types LC..A, LC..B, LFA
Nominal sizes 16 to 160
Detailed information:RE 21 010
Nominal size 16 25 32 40
Operating pressure pmax bar up to 420 3) up to 420 3) up to 420 3) up to 420 3)
Flow 1) qV max L/min 290 600 750 1270
Flow 2) qV max L/min 320 800 ≈ 900 1500
Nominal size 50 63 80 100
Operating pressure pmax bar up to 420 3) up to 420 3) up to 420 3) up to 420 3)
Flow 1) qV max L/min 1950 2750 4500 7500
Flow 2) qV max L/min 2750 ≈ 3750 6200 10600
Nominal size 125 160
Operating pressure pmax bar up to 420 3) up to 420 3)
Flow 1) qV max L/min 11500 18000
Flow 2) qV max L/min 16000 ≈ 25000
1) ∆p ≈ 10 bar, with damping nose2) ∆p ≈ 10 bar, without damping nose3) Depending on pilot valve
= Preferred product range
76
Nominal size 16 25 32 40 50
Operating pressure p max bar 315 315 315 315 315
Weight m kg 0,7 1,5 3,0 5,5 8,1
2-way cartridge valve with directional functionsISO 7368
• For fitting into a manifold block
• Various opening pressures
• Poppet valve area ratios– 1:1– 1:1.6– 1:1.8
• With shaft seal
• With stepped spool
Detailed information:AKY 011/1
*∆p = 8 bar
** Not standard
Detailed information:AKY 011/1
Pilot directional control valves
• For mounting into the valve covers• Various functions (symbol / spools)
Detailed information:AKY 011/1
Valve cover
• For mounting directional spool valves
• Types– Direct directional functions– With integrated shuttle valve
2-way cartridge valve with directional functionsValve coverPilot directional control valves
Nominal size 6
Operating pressure pmax bar 315
Flow qV max L/min 90
El. connection U[V] f[Hz] 024/00
Nominal size 10** 16 25 32 40 50
Operating pressure p max bar 315 315 315 315 315 315
Flow qV max* L/min 210 370 820 1130 1600 2150
77
2-way cartridge valves with pressure relief andpressure sequencing functionTypes LC..DB, LFA..DB and LC..DZ, LFA..DZ
2-way cartridge valves with pressure relief function
• Cartridge:– With directional poppet valve (version "E")– With directional spool valve (version "D")
• Power part as cartridge valve in standardised mounting cavity(DIN 24 342)
• Various control valves for manual or electrical-proportionalpressure adjustment, optional– Integrated in the control cover– Mounted onto the control cover as pilot valve
(connection dimensions to DIN 24 340)
• 7 pressure stages, optional:25, 50, 100, 200, 315, 400 or 420 bar
Type LC..DB (cartridge)
Type LFA..DB (control cover)
Nominal sizes 16 to 100
Detailed information:RE 21 050
Nominal size 16 25 32 40
Operating pressure pmax bar 420 420 420 400
Flow ("E") qV max L/min 250 400 600 1000
Flow ("D") qV max L/min 175 300 450 700
Nominal size 50 63 80 100
Operating pressure pmax bar 400 400 400 400
Flow ("E") qV max L/min 1600 2500 4500 7000
Flow ("D") qV max L/min 1400 1750 3200 4900
2-way cartridge valves with pressure sequencing function
• Pressure-related sequencing of a second system (e.g. high-pressure/low-pressure coupling of two pumps), optional
• Pressure-independent selection of the required spool position bymeans of electrically operated pilot valve, optional(not included within the scope of supply)
• Power part as cartridge valve in standardised mounting cavity(DIN 24 342), closed with standard cover
• Pilot valves for manual pressure adjustment, optional– Integrated in the control cover– Pilot valves for manual pressure adjustment, optional
(connection dimensions to DIN 24 340)
• Various, adjustable max. sequencing pressures (up to 315 bar),optional
Type LC..DB (cartridge)
• With directional poppet valve ("E")• With directional poppet valve ("D")
Type LFA..DZ (control cover)
Type LFA..DZW (control cover forDZ function with pressure-relatedsequencing)
Nominal sizes 16 to 50
Detailed information:RE 21 050
Nominal size 16 25 32 40 50
Operating pressure pmax bar 350 350 350 350 350
Flow ("E") qV max L/min 250 400 600 1000 1600
Flow ("D") qV max L/min 175 300 450 700 1400
= Preferred product range
78
2-way cartridge valves with pressure relief functionsValve coverPilot pressure valves
Nominal size 6
Operating pressure pmax bar 315
2-way cartridge valve withpressure relief functions ISO 7368
• For fitting into a manifold
• Various opening pressures
• Poppet valve area ratio– 1:1
• With and without fine control grooves
Detailed information:AKY 011/1
*∆p = 8 bar
** Not standard
Detailed information:AKY 011/1
Pilot pressure valves
• For mounting onto the valve covers• DBV functions with up to 2 pressure stages
and various directional valve controls
• Pilot control is also possible via proportional valves
• Realisation of sequence and cut-off functions
Detailed information:AKY 011/1
Valve cover
• For mounting pressure valves
• Types– Pressure valve functions– Pressure switching functions– Pilot operated check valve
Nominal size 10** 16 25 32 40 50
Operating pressure p max bar 315 315 315 315 315 315
Flow qV max* L/min 210 370 820 1130 1600 2150
Nominal size 16 25 32 40 50
Operating pressure p max bar 315 315 315 315 315
Weight m kg 0.7 1.5 3.0 5.5 8.1
79
2-way cartridge valves with pressure reducing functionsTypes LC..DR, LFA..DB, LC..DB, LFA..DR
2-way cartridge valves with pressure reducing function
• When the set pressure is reached, the pressure in port A islimited according to the pressure/flow characteristics
• With fine control lands, optional
• Power part as cartridge valve in standardised mounting cavity(DIN 24 342), closed with control cover
• Various pilot valves for manual and electrical-proportionalpressure adjustment, optional– Integrated in the control cover– Mounted onto the control cover as pilot valve
(connection dimensions to DIN 24 340)
• Closing pressures, optional: 2, (3), 4, 5 and 8 bar
Type LC..DR (cartridge)Normally open
Type LFA..DB (control cover)
Nominal sizes 16 to 100
Detailed information:RE 21 050
Nominal size 16 25 32 40
Operating pressure pmax bar 315 315 315 315
Flow qV max L/min 150 270 450 900
Nominal size 50 63 80 100
Operating pressure pmax bar 315 315 315 315
Flow qV max L/min 1100 1700 2800 4400
2-way cartridge valves with pressure reducing function
• When the set pressure is reached, the pressure in port B islimited according to the pressure/flow characteristics
• Cartridge valve only with directional spool valve
• Power part as cartridge valve in standardised mounting cavity(DIN 24 342), closed with control cover
• Various pilot valves for manual and electrical-porportionalpressure adjustment, optional
• Pilot valve mounted onto the control cover (connectiondimensions to DIN 24 340)
Type LC..DB (cartridge)Normally closed
Type LFA..DR (control cover)
Nominal sizes 16 to 100
Detailed information:RE 21 050
Nominal size 16 25 32 40
Operating pressure pmax bar 315/350 315/350 315/350 315/350
Flow qV max L/min 175 300 450 700
Nominal size 50 63 80 100
Operating pressure pmax bar 315/350 315/350 315/350 315/350
Flow qV max L/min 1400 1750 3200 4900
= Preferred product range
80
2-way cartridge valves with pressure reducing valvesValve coverPilot pressure valves
Nominal size 6
Operating pressure pmax bar 315
2-way cartridge valves withpressure reducing valves ISO 7368
• For fitting into a manifold
• Various opening pressures
• Poppet and spool valve area ratios– 1:1
• With stepped spool
Detailed information:AKY 011/1
*∆p = 8 bar
Detailed information:AKY 011/1
Pilot pressure valves
• For mounting onto the valve covers• DBV functions with up to 2 pressure stages
and various directional valve controls
• Pilot control is also possible via proportional valves
• Realisation of sequence and cut-off functions
Detailed information:AKY 011/1
Valve cover
• For mounting pressure valves
Nominal size 16 25 32 40 50
Operating pressure pmax bar 315 315 315 315 315
Flow qV max* L/min 370 820 1130 1600 2150
Nominal size 16 25 32 40 50
Operating pressure p max bar 315 315 315 315 315
Weight m kg 0.7 1.5 3.0 5.5 8.1
81
2-way cartridge valvesSpecial valves
Detailed information:AKY 011/1
*∆p = 8 bar
2-way cartridge valvesBack pressure valves
• For fitting into a manifold
• Various opening pressures
• Area ratio– 1:1
Detailed information:AKY 011/1*∆p = 0.5 bar** B – A / A – B
Anti-cavitation valves for presses
• For fitting into a manifold
• Opening pressure 3.0 bar
• Poppet valve area ratio– 1:1,6
Nominal size 25 32 40 50
Operating pressure pmax bar 315 315 315 315
Pressure in X pmin bar 4 to 5
Flow qV max* L/min 150/205** – – –
Nominal size 16 25 32 40 50
Operating pressure pmax bar 315 315 315 315 315
Flow qV max* L/min 370 820 1130 1600 2150
82
Valves with position switches
Detailed information:AKY 011/2BEY 011/9
Valves with an inductive position switchStandard directional valves
• Concept and designed to meet the machinery directives• Certification of conformaty is available
• Design tested by the relevant Health and Safety Authority
• Precise monitoring of all of the switched positions
Detailed information:AKY 011/2BEY 011/9
Valves with an inductive position switchProportional directional valves
• Concept and designed to meet the machinery directives• Certificate of conformaty is available
• Design tested by the relevant Health and Safety Authority
• Precise monitoring of all of the switched positions
Nominal size 6 10 16 25
Operating pressure pmax bar 315 315 350 350
Flow qV max L/min 60 90 200 500
Nominal size 10 16 25
Operating pressure pmax bar 315 315 315
= Preferred product range
83
Valves with position switches
Detailed information:AKY 011/2BEY 011/9
*∆p = 8 bar
Valves with an inductive postion switch2-way cartridge valves with standard andstepped spool• Concept and designed to meet the
machinery directives
• Certification of conformaty is available
• Design tested by the relevant Health and Safety Authority
• Precise monitoring of all of the switched positions
Detailed information:AKY 011/2BEY 011/9
Valves with a mechanical position switchMicro switch directional valves
• Concept and designed to meet themachinery directives
• Certification of conformaty is available
• Design tested by the relevant Health and Safety Authority
• Precise monitoring of all of the switched positions
Nominal size 16 25 32 40 50
Operating pressure pmax bar 315 315 315 315 315
Flow qV max* L/min 370 820 1130 1600 2150
Nominal size 6 10
Operating pressure pmax bar 315 315
Flow qV max L/min 90 130
= Preferred product range
84
Load control units
Detailed information:AKY 007/3
Load control units• Valve combination of pressure, throttle, directional valve
of poppet design, electrically operated
• To hold and defined unlocking of lifting platforms
Nominal size 6 10
Operating pressure pmax bar 160/270 300
Flow qV max L/min 30 52/60
= Preferred product range
85
PROPORTIONAL, HIGH RESPONSE ANDSERVO VAVLESProportional valves
It is no longer possible to think of removingproportional valves with their integratedelectronics from many controls. They reducethe wiring requirements, simplify handling,have precise reproducability and highswitching performance.
The performance profile
• Proportional, pressure, flow anddirectional valves NS 6 to 35
• Maximum flow > 1000 L/min
• Maximum operating pressure up to 315 bar
• Proportional solenoid with closed-loopposition control for high accuracies(< 1 %) and dynamics
• Robust electronics for industrial andmobil applications
High response valves
High response valves are compact androbust, they provide high dynamics andcontrol accuracy. The NS 6 core product canbe freely combined with the main stageswith up to 1000 litres nominal flow.
The performance profile
• Maximum flow 1000 L/min
• Maximum operating pressure up to 315 bar
• NS 6 to 35
• Highly dynamic valves with zero overlapfor use with closed-loop control cirucits
• Direct and pilot operated
• For manifold and subplate mounting
Servo valves
Servo valves are hydraulic pilot operated 2-or 3-stage directional valves with a portingpattern to DIN 24 340 form A. They aremainly used for the closed-loop control ofposition, force or pressure and speed.
Their features are:
• A compact design
• A low electrical power consumption
• High dynamics
• And excellent quasi-static values
The performance profile
• Maximum flow 1600 L/min
• Maximum operating pressure up to 315 bar
• NS 6 to 32
86
Proportional directional valves, types 4WRA, 4WRAE and 4WRAF
Nominal size 6 10
Operating pressure pmax bar 315 315
Nominal flow (∆p = 10 bar) qV nom L/min 7; 15; 26 30; 60
Hysteresis, max. % 5 5
Step response 0 to 90 % Tu+Tg ms < 40 < 140
Operating voltage U V 24 24
Command value signal for type 4WRAE U V ± 10 ± 10or I mA 4 to 20 4 to 20
Control electronics for type 4WRA Analogu VT-VSPA2-1Digital VT-VSPD-1
Proportional directional valve, direct operated,without electrical position feedback
• For controlling the direction and volume of a flow
• Proportional solenoid operation
• Spring-centered control spool
• Different spool overlaps possible
• Integrated control electronics for type 4WRAE
Types 4WRA, 4WRAE, 4WRAF
Nominal sizes 6 and 10
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 055 (Types 4WRA, 4WRAE)
RE 29 055-02-M (Type 4WRAF)
With Bus interface
• Version for CAN-Bus with CAN-Open protocol (DS 408)
• Separate plugs for power supply and Bus connection
• Command values can be applied analogue or via the Bus
• Zero point correction and overlap compensation can beparameterised via the Bus
Types 4WRAE, 4WRA
Type 4WRAF
= Preferred product range
87
Proportional directional valves, types 4WRE, 4WREE and 4WREF
Nominal size 6 10
Operating pressure pmax bar 315 315
Nominal flow (∆p = 10 bar) qV nom L/min 8; 16; 32 25; 50; 75
Hysteresis, max. % 0.1 0.1
Step response 0 to 90 % Tu+Tg ms 20 40
Operating voltage U V 24 24I A < 2 < 2
Command value signal U V ± 10 ± 10or I mA 4 to 20 4 to 20
Control electronics for type 4WRE Analogue VT-VSPADigital VT-VRPD2-1
Proportional directional valves, direct operated,with electrical position feedback
• For controlling the direction and volume of a flow
• Proportional solenoid operation
• Spring-centered control spool
• Different spool overlaps possilbe
• Position sensing of the control spool via an inductive positiontransducer
• Integrated control electronics for type 4WREE
Types 4WRE, 4WREE, 4WREF
Nominal sizes 6 and 10
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 061 (Types 4WRE, 4WREE)
RE 29 061-02-M (Type 4WREF)
With Bus interface
• Version for CAN-Bus with CAN-Open protocol (DS 408)
• Separate plugs for power uspplay and Bus connection
• Command value can be applied analogue or via the Bus
• Zero point correction and overlap compensation can beparameterised via the Bus
Types 4WREE, 4WRE
Type 4WREF
= Preferred product range
88
Proportional directional valves type 4WREEMProportional directional valves type KKS
Nominal size 6 10
Operating pressure pmax bar 315 315
Nominal flow (∆p = 10 bar) qV nom L/min 8; 16; 32 25; 50; 75
Hysteresis, max. % ≤ 0.1 ≤ 0.1
Step response 0 to 90 % Tu+Tg ms 20 40
Operating voltage U V 24 24
Command value signal U V ± 10 ± 10
Proportional directional valves, direct operated, withintegral control electronics, electrical spool positionfeedback and monitoring of the spool position
• For controlling the direction and volume of a flow
• Proportional solenoid operation
• Spring-centered control spool
• Different spool overlaps possible
Type 4WREEM
Nominal sizes 6 and 10
Porting pattern to DIN 24 340, form A,ISO 4401 and CETOP-RP 121 H
Detailed information:RE 29 064
Build size 1
Operating pressure pmax bar 210
Nominal flow qV nom L/min1 → 2 352 → 1 30
Hysteresis, max. % 5
Jump response 0 to 100 % Tu+Tg ms < 90100 to 0 % Tu+Tg ms < 60
Operating voltage U V 24
Command value signal U V 0 to + 10
Control electronics Module VT-MSPA1-50-1X
2/2 proportional directional valves, direct operated• Control of the direction and rate of flow
• Operation via a proprtional solenoid with centre thread andremovable coil
• Coil can be rotated
• Flow can pass in both directions
• With protected hand override, optional
Type KKS
Build size 1
Detailed information:RE 18 139-02
= Preferred product range
89
Proportional directional valves types 4WRZ, 4WRZE and 4WRZF
Nominal size 10 16 25 32 52
Operating pressure pmax bar 315 350 350 350 350
Nominal flow (∆p = 10 bar) qV nom L/min 25; 50; 85 100;150 220; 325 360; 520 1000
Hysteresis, max. % 6 6 6 6 6
Jump response 0 to 90 % Tu+Tg ms 40 70 90 170 450
Operating voltage U V 24 24 24 24 24
Control electronics for type 4WRZ Analogue VT-VSPA2-5.Digital VT-VSPD-1Modular design VT 11118; VT 11011
Proportional directional valves, pilot operated,without electrical position feedback
• Control of the direction and rate of a flow
• Pilot control via a 3-way pressure reducing valve
• Spring centring and anti-rotation device for the main spool
• Various spool overlaps are possible
• Optionally with integrated electronics
Types 4WRZ, 4WRZE, 4WRH, 4WRZF
Nominal sizes 10 to 52
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 115 (types 4WRZ, 4WRZE)
RE 29 115-02-M (type 4WRZF)
With bus interface
• Version for CAN bus with CAN-open-protocol (DS 408)
• Separate plugs for the power supply and bus connections
• Command value can be applied analogue or via a bus
• Zero point correction and overlap compensation can beparameterised via the bus
Type 4WRZE
Type 4WRZF
= Preferred product range
90
High-response directional valves, direct operated,with electrical position feedback
• For controlling the direction and volume of a flow
• Suitable for closed-loop position, velocity and pressure control
• Control solenoid operated
• Spring-centered control spool
• Position sensing of the control spool via an inductive postiontransducer
• Integrated control electronics
Types 4WRSE, 4WRSEH
Nominal sizes 6 and 10
Porting pattern to DIN 24 340, form A
Detailed information:• RE 29 067 (type 4WRSE)• RE 29 069 (type 4WRSEH)
Nominal size 6 10
4WRSE 4WRSEH 4WRSE 4WRSEH
Operating pressure pmax bar 315 315 315 315
Nominal flow (∆p = 70 bar) qV nom L/min 10; 20; 35 4; 12; 24; 50 25; 50; 75 50; 100
Hysteresis, max. % 0.05 0.05 0.05 0.05
Frequency at -90° phase response Hz 100 100 70 65
Operating voltage U VDC 24 24 24 24
Command value U V ± 10 ± 10 ± 10 ± 10or I mA 4 to 20 4 to 20 4 to 20 4 to 20
Proportional directional valves type 4WRKEHigh-response directional valves type 4WRSE(H)
Proportional directional valves, pilot operated,with electrical position feedback
• For controlling the direction and volume of a flow
• Pilot control using a 3-way proportional directional valvewithout position feedback
• Spring-centering of the main spool
• Position sensing of the main spool via and inductive positiontransducer
Type 4WRKENominal sizes 10 to 35
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 075
Nominal size 10 16 25 32 35
Operating pressure pmax bar 315 350 350 350 350
Nominal flow (∆p = 10 bar) qV nom L/min 25; 50; 125; 220; 400; 100090 200 350 600
Hysteresis, max. % 1 1 1 1 1
Step response 0 to 90 % Tu+Tg ms 20 30 50 80 120
Supply voltage U V 24 24 24 24 24
Command value signal for type 4WRKE U V ± 10 ± 10 ± 10 ± 10 ± 10I mA 4 to 20 4 to 20 4 to 20 4 to 20 4 to 20
= Preferred product range
91
High-response directional valves type 4WRTEHigh-response directional valves type 4WRDE
High-response directional valves, pilot operated,with electrical position feedback
• For controlling the direction and volume of a flow
• Suitable for closed-loop force, position, velocity and pressurecontrol
• Pilot control using a 3-way high-response control valve withposition feedback
• Self-centering main stage
• Position sensing of the main spool via an inductive positiontransducer
• Integrated control electronics
Nominal size 10 16 25 32 35
Operating pressure pmax bar 315 350 350 350 350
Nominal flow (∆p = 10 bar) qV nom L/min 25; 50; 125; 220; 400; 1000100 200 350;500 600
Hysteresis, max. % 0.1 0.1 0.1 0.1 0.1
Frequency at -90° phase response Hz 100 65 60 35 30
Operating voltage U V 24 24 24 24 24I A 3 3 3 3 3
Command value signal U V ± 10 ± 10 ± 10 ± 10 ± 10or I mA 4 to 20 4 to 20 4 to 20 4 to 20 4 to 20
Type 4WRTE
Nominal sizes 10 to 32
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 083
High-response directional valves,pilot operated, with electrical position feedback
• For controlling the direction and volume of a flow
• Suitable for closed-loop force, position, velocity and pressurecontrol
• Pilot control using a two-stage servo-valve (NS 6)
• Position sensing of a main spool via an inductive positiontransducer
• Integrated control electronics
Type 4WRDENominal sizes 10 to 32
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 093
Nominal size 10 16 25 32
Operating pressure pmax bar 315 350 350 350
Nominal flow (∆p = 10 bar) qV nomL/min 50;100 125;200 220;350;500 600
Hysterese, max. % 0.2 0.2 0.2 0.2
Frequency at - 90° phase response f Hz 150 140 130 90
Operating voltage U V 24 24 24 24
Command value signal for type 4WRDE U V ± 10 ± 10 ± 10 ± 10
= Preferred product range
92
Servo valves type 4WS.2E.Servo valves type 4WSE3EE
2-stage servo valves, mechanical and electrical feedback
• For controlling the direction and volume of a flow
• Suitable for closed-loop force, position, velocity and pressurecontrol
• 1st stage nozzle/flapper plate amplifier
• Dry torque motor
• Wear-free connection of spool with feedback element
• Position sensing of the main spool via an inductive positiontransducer in the case of valves with electrical feedback(nominal size 10)
• Integrated control electronics for type 4WSE2E.
3-stage servo valves, electrical feedback• For controlling the direction and volume of a flow
• Suitable flor closed-loop force, position, velocity and pressurecontrol
• High response sensitivity, very low hysteresis and zero point drift
• Position sensing of the main spool via an inductive positiontransducer
• Integrated control electronics
Type 4WS.2E.
Nominal sizes 6 and 10
Porting pattern to DIN 24 340, form A
Detailed information:• Nominal size 6 –RE 29 564• Nominal size 10 –RE 29 583
• Nominal size 16 –RE 29 591
Type 4WSE3EENominal sizes 16 to 32
Porting pattern to DIN 24 340, form A
Detailed information:• RE 29 595
Nominal size 16 25 32
Operating pressure pmax bar 315 315 315
Nominal flow (∆p = 70 bar) qV nom L/min 100; 150;300; 500; 700;200; 300 400; 500 1000
Hysteresis, max. % 0,2 0,2 0,2
Corner frequency – 90° (± 25 %, 315 bar) f Hz 140 140 110
Operating voltage U V ± 15 ± 15 ± 15
Command value signal U V ± 10 ± 10 ± 10or I mA ± 10 ± 10 ± 10
1) At 210 bar
Nominal size 6 10 16
Operating pressure pmax bar 315 315 315
Nominal flow (∆p = 70 bar) qV nom L/min 2; 5; 10; 20; 30; 45; 100; 150;15; 20 60; 75; 90 200
Hysteresis, max. % ≤ 1,5 1) ≤ 1,5 ≤ 1,5
Corner frequency – 90° (± 25 %, 315 bar) f Hz 250 180 75
Operating voltage for type 4WS2E U V ± 15 ± 15 ± 15
Command value signal for type 4WSE2E. U V ± 10 ± 10 ± 10or I mA ± 10 ± 10 ± 10
Control electronics for type 4WS2E. Analogue VT-SR2 VT-SR2(depending on coil or feedback) Modular design VT 11021
= Preferred product range
93
Proportional directional valves type WV1with/without integrated electronics
Proportional directional valves, direct operated,without electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control of the direction and rate of a flow
• Operated via a proportional solenoid
• Spring centred main spool
• Modular design with various valve symbols
• Standard signal +/– 10 V
• OBE also possible with 4 to 20 mA
Type WV1
Nominal sizes 6 and 10
Detailed information:AKY 013/1 Chapters 6 and 7
For control electronics see page 116
Proportional directional valves, direct operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A– Without integrated electronics (Ns10 with „L“ connection)
• Control of the direction and rate of a flow
• Operated via a proportional solenoid
• Spring centred main spool
• Modular design with various valve symbols
• Spool position acquisition via an inductive position transducer• Variants
- As a high response valve „RV 1-2 M“ on request
Type WV1
Nominal sizes 6 and 10
Detailed information:AKY 013/1 Chapters 6 and 7
High response valveAKY 013/1 Chapter 6, page 168AKY 013/1 Chapter 7, page 194
For control electronics see page 117
Variant with OBE-D/CAN-open on request
Nominal size 6 10
Operating pressure pmax bar 315 315
Nominal flow (∆p = 10 bar) qV nom L/min 5.8 to 32 32 to 65
Hysteresis, max. % 4 6
Jump response 0 to 90 % Tu+Tg ms < 70 < 100
Operating voltage U Vnom 24 24
Command value signal Standard = U V ± 10 ± 10also OBE with = I mA 4 to 20 4 to 20
Control electronics Modular 2 M 2.5 - RGC 2Circuit cards 2 M 45 - 2.5 A
Nominal size 6 10
Operating pressure pmax bar 315 315
Nominal flow (∆p = 10 bar) qV nom L/min 8 to 32 32 to 80
Hysterese, max. % 0.3 0.3
Jump response 0 to 90 % Tu+Tg ms < 20 < 40
Operating voltage U Vnom 24 24
Command value signal Standard = U V ± 10 ± 10also OBE with = I mA 4 to 20 4 to 20
Control electronics Circuit cards WV45 -RGC2 WV60 -RGC2WV45 -RGC4 WV60 -RGC4 = Preferred product range
94
High response valves type RV1-PL1/ type RV1-HRVwith/without integrated electronics
High response valves, direct operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control of the direction and rate of a flow
• For use with position, speed andpressure closed-loop control
• Operation via a high response solenoid
• Control spool position acquistion via an inductive positiontransducer
• Series- With/without integrated electronics
• Charateristic curves with and without inflection
Type RV1-PL1
Nominal size 6
Detailed information:AKY013/2 Chapters 1 and 3
For control electronics see page 119Variants with OBE-D2 on request
High response valves, direct operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control of the direction and rate of a flow
• For use closed-loop control with high dynamics
• Operated via a double stroke high response solenoid
• Control spool position acquistion via an inductive positiontransducer
• Series- With integrated electronics
• Charateristic curves with and without inflection
Type RV1-HRV1
Nominal size 6
Detailed information:AKY013/2 Chapter 2
Nominal size 6
Operating pressure pmax bar 315
Nominal flow (∆p = 70 bar) qV nom L/min 2 to 40
Hysteresis, max. % < 0.2
Frequency at -90° phase response f Hz ≥ 120
Operating voltage U Vnom 24
Command value U V ± 10 or I mA 4...12...20
Control electronics circuit card PL6
Nominal size 6
Operating pressure pmax bar 315
Nominal flow (∆p = 70 bar) qV nom L/min 8 to 40
Hysteresis, max. % < 0.2
Frequency at -90° phase response f Hz250
Operating voltage U Vnom 24
Command value U V ± 10
= Preferred product range
95
High response valves type RV1-PL1 / Type RV1-p/Q1with/without integrated electronics
High response valves, direct operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control the direction and rate of a flow
• For use with position, speed andpressure closed-loop control
• Operation via a high response solenoid
• Control spool position acquisition via an inductive positiontransducer
• Series- With/without integrated electronics
• Characteristic curves with and without inflection
Type RV1-PL1
Nominal size 10
Detailed information:AKY013/2 Chapters 5 and 6
For control electroncis see page 119Variants with OBE-D2 on request
High response valves, direct operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control of a flow P – A / A – T
• For use with speed and pressure closed-loop controls
• Operation via a high response solenoid
• Control spool position acquisition via an inductive positiontransducer
• Series- With integrated electronics
• Linear characteristic curves
Type RV1-p/Q1
Nominal size 10
Detailed information:AKY013/2 Chapters 7 and 8
For control electronics see pages 120, 124
Nominal size 10
Operating pressure pmax bar 315
Nominal flow (∆p = 70 bar) qV nom L/min 50 to 100
Hysteresis, max. % < 0.2
Frequency at -90° phase response f Hz 60
Operating voltage U Vnom 24
Command value U V ± 10 or I mA 4 to 20
Control electronics circuit card PL10
Nominal size 10
Operating pressure pmax bar 210
Nominal flow (∆p = 11 bar) qV nom L/min 70/70
Hysteresis, max. % < 0.3
Frequency at -90° phase reponse f Hz 70
Operating voltage U Vnom 24
Command value U V ± 10
Control electronics circuit card p/Q
= Preferred product range
96
Nominal size 10 16 25 32**
Operating pressure pmax bar 350 350 350 350
Nominal flow (∆p = 10 bar) qV nom L/min 50/80 180 230/350 1100
Hysteresis, max. % < 0.1 < 0.1 < 0.1 < 0.1
Jump response 0 to 90 % Tu+Tg ms 20 30 50 120
Supply voltage U Vnom 24 24 24 24
Command valve signal Standard U V ± 10 ± 10 ± 10 ± 10With OBE I mA 4 bis 20 4 to 20 4 to 20 4 tp 20
Control electronics circuit card 2 STV2 STV-RGC2
Proportional directional valves type WV2-DSP, High response valves type WV2-HPPwith integrated electronics
High response valves, pilot operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control of the direction and rate of a flow
• Pilot control via a 4/4-way high response valvewith postion feedback
• Spring centring of the main spool, fail safe
• Main spool position acquistion via an inductive positiontransducer
• Modular design with various valve symbols
• Series- With/without integrated electronics
Type WV2-HPPNominal sizes 10 to 32
Detailed information:AKY 013/3 Chapters 2 and 3
Chapter 2
For control electronics see page 118
Variants with OBE-D/CAN-open on request** Connection drilling Ø 50
Proportional directional valves, pilot operatedwith electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control of the direction and rate of a flow
• Pilot control via a 3-way proportional directional valvewithout postion feedback
• Spring centring of the main spool
• Main spool position acquistion via an inductive positiontransducer
• Modular design with various valve symbols
• Higher solenoid/direction switch-off withISA adaptor
Type WV2-DSP
Nominal sizes 10 to 32
Detailed information:AKY 013/3 Chapter 1
* Connection drilling Ø 32
** Connection drilling Ø 50
Nominal size 10 16 25* 32**
Operating pressure pmax bar 350 350 280 350
Nominal flow (∆p = 10 bar) qV nom L/min 50/80 180 230/430 1100
Hysteresis, max. % 0.3 0.3 0.3 0.3
Jump response 0 to 90 % Tu+Tg ms < 35 < 55 < 60 < 140
Supply voltage U Vnom 24 24 24 24
Command value signal Standard U V ± 10 ± 10 ± 10 ± 10
= Preferred product range
97
High response valves type RV2-PL2 / type RV2-HRV2with/without integrated electronics
High response valves, pilot operated,with electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control the direction and rate of a flow
• For use with force position, speed andpressure closed-loop control
• Pilot control valve type RV-PL
• The pilot control valve and main stage are closed-loop positioncontrolled
• Modular design with various valve symbols
• Series- With/without integrated electronics
• Characteristic curves with and without inflection
Type RV2-PL2
Nominal sizes 10 to 32
Detailed information:AKY013/2 Chapters 9 and 11
For control electronics see page 119Variants with OBE-D2 on request
* At 100 bar
** Connection drilling Ø 50
High response valves, pilot operated,with electrical position feedback
• Porting pattern to DIN 24 340, form A
• Control the direction and rate of a flow
• For use with closed-loop controls with high dynamics
• Pilot control valve type RV-HRV
• Modular design with various valve symbols
• Series- With integrated electronics
• Characteristic curves with and without inflection
Type RV2-HRV2
Nominal sizes 10 to 25
Detailed information:AKY013/2 Chapter 10
Nominal size 10 16 25 32**
Operating pressure pmax bar 350 350 350 350
Flow (∆p = 10 bar) qV nom L/min 55;80 120;200 370 1000
Hysteresis, max.* % ≤ 0.1
Frequency at - 90° phase response* f Hz 45 45 50 20
Operating voltage * U Vnom 24 24 24 24
Command value signal Standard = U V ± 10 ± 10 ± 10 ± 10also OBE with = I mA 4...12...20
Control electronics circuit card 2 STV
Nominal size 10 16 25
Operating pressure pmax bar 350 350 350
Flow (∆p = 10 bar) qV nom L/min 55;80 120;200 370
Hysteresis, max. % ≤ 0.1
Frequency at - 90° phase response f Hz 100 100 55
Operating voltage U Vnom 24 24 24
Command value signal U V ± 10 ± 10 ± 10
= Preferred product range
98
Proportional pressure relief valves, types DBET and DBETEProportional pressure relief valves, types (Z)DBE 6 and (Z)DBEE 6
Proportional pressure relief valves, direct operated
• Valve for limiting a system pressure
• Proportional solenoid operated
• For subplate mounting
• Integrated control electronics for type DBETE
• Linearised pressure/command value characteristic curve for typeDBETE
Proportional pressure relief valves, pilot operated
• Valve for limiting a system pressure
• Proportional solenoid operation
• For subplate mounting, types DBE 6 and DBEE 6
• Sandwich plate version, types ZDBE 6 and ZDBEE 6
• Integrated control electronics for types DBEE 6 and ZDBEE 6
• Linearised pressure/command value characteristic curve
Nominal size 6
Operating pressure pmax bar 350
Flow qV max L/min 2
Hysteresis, max. % ± 1.5 of max. set pressure
Step response 0 to 100 % Tu+Tg ms 30 bis (depending100 to 0 % Tu+Tg ms 120 on system)
Operating voltage U V 24
Command value signal U V 0 to 10
Control electronics for type DBET Analogue VT-VSPA1-1 and VT 2000Digital VT-VSPD-1Modular design VT 11030
Types DBET and DBETE
Nominal size 6
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 165
Nominal size 6
Operating pressure pmax bar 315
Flow qV max L/min 30
Hysteresis, max. % ± 1.5
Step response 10 to 90 % Tu+Tg ms 80 (depending90 to 10 % Tu+Tg ms 50 on system)
Operating voltage U V 24
Command value signal U V 0 to 10
Control electronics for type (Z)DBE 6 Analogue VT-VSPA1-1Digital VT-VSPD-1Modular design VT 11031
Types (Z)DBE 6 and (Z)DBEE 6Nominal size 6
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 158
= Preferred product range
99
Proportional pressure relief valves, pilot operated
• Valve for limiting a system pressure
• Operated by means of a proportional solenoid
• For subplate mounting
• Maximum pressure relief function for types DBEM and DBEME
• Integrated control electronics for types DBEE and DBEME
• Linearised pressure/command value characteristic curve (NS 10and 25)
Nominal size 10 25 32
Operating pressure pmax bar 350 350 350
Flow qV max L/min 200 400 600
Hysteresis, max. % ± 1.5 ± 1.5 ± 1.5
Step response 0 to 100 % Tu+Tg ms 150 150 150 (depending100 to 0 % Tu+Tg ms 150 150 150 on system)
Operating voltage U V 24 24 24
Command value signal U V 0 to 10 0 to 10 0 to 10
Control electronics for type DBE Analogue VT-VSPA1-1 VT-VSPA1-1 VT-VSPA1-1Digital VT-VSPD-1 VT 2000Modular design VT 11131 VT-VSPD-1
Types DBE(M) and DBE(M)ENominal sizes 10, 25 and 32
Porting pattern to DIN 24 340, form E
Detailed information:• Nominal sizes 10 and 25
RE 29 160
• Nominal size 32RE 29 142
Proportional pressure relief valves, type DBETREProportional pressure relief valves, types DBE(M) and DBE(M)E
Proportional pressure relief valves, direct operated
• Valve for limiting a system pressure
• Operated by means of a proportional solenoid with positiontransducer
• For subplate mounting
• Integrated control electronics
Type DBETRE
Nominal size 6
Porting pattern to DIN 24 340, form A andISO 4401
Detailed information:RE 29 168
Nominal size 6
Operating pressure pmax bar 380
Flow qV max L/min 2 bis 3 1)
Hysteresis, max. % ± 1
Step response 0 to 100 % Tu+Tg ms 30 to (depending100 to 0 % Tu+Tg ms 120 on system)
Operating voltage U V 24
Command value signal U V 0 to 10 1) Depending on pressure stage
= Preferred product range
100
Proportional pressure relief valves type DBEPProportional pressure relief valves type KBPS
Build size Pilot valve
Operating pressure pmax bar 350
Flow qV max L/min 2
Hysteresis, max. % 4
Jump response 0 to 100 % Tu+Tg ms < 70100 to 0 % Tu+Tg ms < 70
Operating voltage U V 24
Command value signal U V 0 to + 10
Control electronics Module VT-MSPA1-1-1X
Proportional pressure relief valves, direct operated
• Direct operated valve for limiting a system pressure
• Operated via a proportional solenoid
• Proportional solenoid with central thread and removable coil
• Cartridge valve
• Fine calibration of the command value-pressure-characteristiccurve externally on the control electronics
Type KBPS
Pilot valve
Detailed information:RE 18 139-03
Proportional pressure relief valves, direct operated
• Valve for limiting a system pressure
• Operated by means of a proportional solenoid
• For subplate mounting
Type DBEP
Nominal size 6
Porting pattern to DIN 24 340, form A andISO 4401
Detailed information:RE 29 164
Nominal size 6
Operating pressure pmax bar 100
Flow qV max L/min 8
Hysteresis, max. % ≤ 3
Operating voltage U V 24
Control electronics Analogue VT-VSPA1-1 and VT 2000Digital VT-VSPD-1
= Preferred product range
101
Proportional pressure reducing valvesTypes 3DREP 6 and 3DREPE 6
Proportional pressure reducing valves, direct operated
• Valve for reducing a system pressure
• Operation by means of a proportional solenoid
• For subplate mounting
Nominal size 6
Operating pressure pmax bar 100
Flow qV max L/min 15
Hysteresis, max. % 5
Operating voltage U V 24
Control electronics for Analogue VT-VSPA2-5.type 3DREP 6 Digital VT-VSPD1
Modular design VT 11118
Types 3DREP 6 and 3DREPE 6
Nominal size 6
Porting pattern to DIN 24 340, form A,ISO 4401 and CETOP-RP 121H
Detailed information:RE 29 184
• Integrated control electronics for type 3DREPE 6
= Preferred product range
102
Proportional pressure reducing valves, type (Z)DRE 6Proportional pressure reducing valves, types ZDRE 10 and ZDREE 10
Proportional pressure reducing valves, pilot operated
• Valve for reducing a system pressure
• Proportional solenoid operation
• For subplate mounting, type DRE 6
• Sandwich plate version, type ZDRE 6
• Linearised pressure/command value characteristic curve
Type (Z)DRE 6
Nominal size 6
Porting pattern to DIN 24 340, form A
Detailed information:RE 29 175
Nominal size 6
Operating pressure pmax bar 210
Flow qV max L/min 30
Hysteresis, max. % ± 2
Step response 10 to 90 % Tu+Tg ms 20090 to 10 % Tu+Tg ms 200
Operating voltage U V 24
Control electronics Analogue VT-VSPA1(K)-1Digital VT-VSPD-1Modular design VT 11132
Proportional pressure reducing valves, pilot operated
• Valve for reducing a system pressure
• Proportional solenoid operation
• Sandwich plate version
• Integrated control electronics for type ZDREE 10
Types ZDRE 10 and ZDREE 10Nominal size 10
Porting pattern to DIN 24 340, form A,ISO 4401 and CETOP-RP121H
Detailed information:RE 29 179
Nominal pressure 10
Operating pressure pmax bar 315
Flow qV max L/min 80
Step response 10 to 90 % Tu+Tg ms 15090 to 10 % Tu+Tg ms 120
Operating voltage Ueff V 22 to 33
Control electronics Analogue VT-VSPA1(K)-1Digital VT-VSPD-1Modular design VT 11131
= Preferred product range
103
Proportional pressure reducing valves, pilot operated
• Valves for reducing a system pressure
• Proportional solenoid operation
• For subplate mounting
• Linearised pressure/command value characteristic curve
• Maximum pressure relief function for types DREM and DREME
• Check valve between ports A and B optional
• Integrated control electronics for types DREE and DREME
Types DRE(M) and DRE(M)E
Nominal sizes 10 and 25
Porting pattern to DIN 24 340, form D
Detailed information:• Nominal sizes 10 and 25
RE 29 176• Nominal sizes 32
RE 29 178
Nominal size 10 25 32
Operating pressure pmax bar 315 315 315
Flow qV max L/min 200 300 300
Hysteresis, max. % ± 2.5 ± 2.5 ± 2.5
Step response 10 to 90 % Tu+Tg ms 130 130 100 to 3001)
90 to 10 % Tu+Tg ms 120 120
Operating voltage U V 24 24 24
Command value signal for type DRE(M)E U V 0 to 10 0 to 10 0 to 10
Control electronics for type DRE(M) Analogue VT-VSPA1(K)-1Digital VT-VSPD-1Modular design VT 11724 VT 11030
Proportional pressure reducing valves, types DRE(M) and DRE(M)EProportional pressure reducing valves, types 3DRE(M) and 3DRE(M)E
Proportional pressure reducing valves, pilot operated• Valves for reducing a system pressure
• Proportional solenoid operation
• For subplate mounting
• Integrated control electronics
Types 3DRE(M) and 3DRE(M)E
Nominal sizes 10 and 16
Porting pattern to DIN 24 340, form A,ISO 4401 and CETOP-RP 121H
Detailed information:RE 29 186
Nominal size 10 16
Operating pressure pmax bar 315 315
Flow (∆p = 10 bar) qV nom L/min 125 300
Hysteresis, max. % ± 2 ± 2
Operating voltage U V 24 24
Control electronics for type 3DRE(M) Analogue VT-VSPA1(K)-1VT 11131
Digital VT-VSPD-1
1) Depending on system
= Preferred product range
104
Proportional pressure relief valves type PV1Pilot control valves with/without closed-loop position control
Proportional pressure relief valves,direct operated without closed-loop position control
• Operated via a proportional solenoid
• Series– With 0.8 A solenoid– With 2.5 A solenoid
• Electronics– Active plug (plug with integrated electronics)– Module– Circuit cards
• Technical data with QN = 1 L/min
• Poppet seat valve with compression spring
Type PV1-DBV
Nominal size 6
Detailed information:AKY013/1 Chapter 1, page 10Active plugAKY013/1 Chapter 12
Proportional pressure relief valves,direct operated with closed-loop position control
• Operated via a proportional solenoid
• Series– Standard characteristic curves– Linear characteristic curves (PDL)– Standard characteristic curves with OBE
• Electronics– Circuit cards– Integrated electronics
• Technical data with QN = 1 L/min
• Poppet seat valve with compression spring
Type PV1-DBV
Nominal size 6
Detailed information:AKY013/1 Chapter 1
AKY013/1 Chapter 1, page 25
Variant with OBE-D/CAN-open on request
Nominal size 6
Pressure stages bar 28 80 180 250 315
Adjustment time 0...100%Standard char. curves ms 45Linear char. curves ms 45Char. curves with OBE ms 35
Hysteresis % < 1; with OBE < 0.2
Command value signal Standard = V 0 to 10also OBE with = mA 4 to 20
Nominal size 6
Pressure stages bar 50 80 180 250 315
Qnom L/min 1
Hysteresis % ≤ 4
Adjustment time On ms < 60Off ms < 70
Com. value signal Standard V 0 to 10Active plug mA 4 to 20
= Preferred product range
105
Proportional pressure relief valves and -pressure reducing valves type PV2with/without closed-loop position control
Proportional 3-way pressure reducing valves,pilot operated
• Operated via a proportional solenoid
• Series– Without closed-loop position control 0.8 A solenoid– With closed-loop position control– With closed-loop position control OBE
• Electronics for series without closed-loop position control– Active plug– Module– Circuit cards
• Electronics for series with closed-loop position control– Circuit cards– Integrated electronics
Proportional pressure relief valves,pilot operated
• Operated via a proportional solenoid
• Series– Without closed-loop position control 0.8 A/2.5 A– With closed-loop position control OBE
• Pilot control supply internally from „P“
• Electronics for series without closed-loop position control– Active plug– Module– Circuit cards
• Electronics for series with closed-loop position control– Integrated electronics
Type PV2-DBV
Nominal size 6
Detailed information:AKY013/1 Chapter 2
Type PV2-DRV-3W
Nominal size 6
Detailed information:AKY013/1 Chapter 2
Nominal size 6
Pressure stages bar 80 180 315
Adjustment times 0...100%Without pos. control ms 200With pos. control ms 70
HysteresisWithout pos. control % ≤ 4With pos. control % < 1
QN max L/min 40
Com. value signal Standard = V 0 to +10also OBE with =/ active plug = mA 4 to 20
Nominal size 6
Pressure stages bar 75 175 310
Adjustment times 0...100%Without pos. control ms 200With pos. control ms 50
HysteresisWithout pos. control % ≤ 4With pos. control % < 1
QN max L/min 40
Com. value signal Standard = V 0 to +10also OBE with = / active plug = mA 4 to 20 = Preferred product range
106
Proportional pressure relief valves and -pressure reducing valves typePV2to ISO 5781
Proportional pressure reducing valves, pilot operated
• Operated via a proportional solenoid
• Series– Without closed-loop position control– With closed-loop position control– With closed-loop position control OBE
• Porting pattern to ISO 5781-AG-06-2-A
• Electronics for series without closed-loop position control– Active plug– Module– Circuit cards
• Electronics for series with closed-loop position control– Circuit cards– Integrated electronics
Proportional pressure relief valves, pilot operated
• Operated via a proportional solenoid
• Series– With/without closed-loop position control– With closed-loop position control OBE
• Porting pattern to ISO 5781-AG-06-2-A
• Electronics for series without closed-loop position control– Active plug– Module– Circuit cards
• Electronics for series with closed-loop position control– Circuit cards– Integrated electronics
Type PV2-DBV
Nominal size 10
Detailed information:AKY013/1 Chapter 3
Type PV2-DRV-2W
Nominal size 10
Detailed information:AKY013/1 Chapter 3
Nominal size 10
Pressure stages bar 180 315
Adjustment times 0...100%Without pos. control ms 90With pos. control ms 80
HysteresisWithout pos. control % ≤ 5With pos. control% ≤ 1
Qnom L/min 120 to max. 300
Com. value signal Standard = V 0 to +10also OBE with = / active plug = mA 4 to 20
Nominal size 10
Pressure stages bar 180 315
Adjustment times 0...100%Without pos. control ms 90With pos. control ms 80
HysteresisWithout pos. control % ≤ 5With pos. control % < 1
Qnom L/min 120 to max. 300
Com. value signal Standard = V 0 to +10also OBE with = / active plug = mA 4 to 20
107
Proportional throttle valves, pilot operated
• 2-way version as cartridge valve• Proportional solenoid operation• Can be used for pressure-compensated flow control in
conjunction with a pressure compensator• Good dynamics and hysteresis, leak-free isolation• Orifice opool position electrically closed-loop position controlled• Integrated control electronics for type FESE• Flow characteristics optionally linear or progressive• Flow in both directions possible
Type FES(E)
Nominal sizes 25, 32, 40, 50 and 63
Installation dimensions to DIN ISO 7365
Detailed information:RE 29 209
Nominal size 25 32 40 50 63
Operating pressure pmax bar 315 315 315 315 315
Max. flow (∆p = 10 bar) qV max L/min 360 480 680 1400 1800
Response sensitivity and % 0.10 0.10 0.10 0.10 0.10range of inversion, max. % 0.15 0.15 0.15 0.15 0.15
Step response 0 to 100 % Tu+Tg ms 50 80 100 200 400100 to 0 % Tu+Tg ms 70 120 160 250 500
Operating voltage U V 24 24 24 24 24
Command value signal U V 0 to 10 0 to 10 0 to 10 0 to 10 0 to 10or I mA 4 to 20 4 to 20 4 to 20 4 to 20 4 to 20
Control electronics Analogue VT-VRPA1-50 VT-VRPA1-51 VT-VRPA1-52Digital VT-VRPD-1Modular design VT 11037
Proportional throttle valves, type FES(E)High-response directional valves, type 3FERE
High-response control valves, pilot operated
• For controlling the direction and volume of a flow
• 3/2-way version as cartridge valve
• Pilot control using a 3/2-way high-response control valve
• In the case of a failure, connection from A to T is openedautomatically
• Main stage orifice spool is closed-loop position controlled bymeans of an inductive position transducer
• Pilot control spool is closed-loop position controlled by means ofan inductive position transducer
• Integrated digital control electronics
• Suitable for closed-loop position, velocity and pressure control
Nominal size 25 32 50
Operating pressure pmax bar 315 315 315
Nominal flow (∆p = 10 bar) qV nom L/min 240 450 800
Hysteresis, max. % 0.1 0.1 0.1
Frequency at - 90° phase response f Hz 70 60 50
Operating voltage U V 24 24 24
Command value signal U V ± 10 ± 10 ± 10or I mA 4 to 20 4 to 20 4 to 20
Type 3FERENominal sizes 25, 32 and 50
Installation dimensions similar toDIN 24 342, form A
Detailed information:RE 29 218
= Preferred product range
108
Proportional cartridge valves, types 2WRC(E) and 3WRC(E)Proportional flow control valves, type 2FRE
Proportional flow control valves, direct operated,2-way version
• Proportional solenoid operation
• Valve with pressure compensator for pressure-compensatedcontrolling of a flow
• Metering orifice closed-loop position controlled using aninductive position transducer, with electrical closed-loop positioncontrol for the metering orifice
• Flow control in both directions by means of recitifier sandwichplate
• Operating voltage of proportional solenoids: 24 V
Type 2FRENominal sizes 6, 10 and 16
Porting pattern• NS 6 to DIN 24 340, form A,
ISO 4401 and CETOP-RP 121H• NS 10 and 16 to DIN 24 340, form G
Detailed information:• Nominal size 6 – RE 29 188• Nominal sizes 10 and 16 – RE 29 190
Nominal size 6 10 16Operating pressure pmax bar 210 315 315Max. flow (∆p = 8 bar) qV max L/min up to 100 up to 60 up to 160Hysteresis, max. % ± 1 ± 1 ± 1Step response 0 to 100 % Tu+Tg ms 60 90 130
100 to 0 % Tu+Tg ms 70 100 90Control electronics Analogue VT 5010 VT 5004
Digital VT-VRPD-1 VT-VRPD-1Modular design VT 11033 VT 11034
Proportional cartridge valves, pilot operated,with electrical position feedback
• Suitable for closed-loop position, velocity and pressure control
• Controlling by means of a servo valve
• Very short switching times, low hysteresis
• Position sensing of the control spool via an inductive positiontransducer
• Integrated control electronics for type .WRCE(nominal sizes 32 to 100)
Types 2WRC(E) and 3WRC(E)Nominal sizes 32 to 160
Installation dimensions to DIN 24 342
Detailed information:• Nominal sizes 32 to 50, series 2X –
RE 29 136• Nominal sizes 63 to 160, series 1X –
RE 29 135
Nominal size 32 40 50 63Operating pressure 2-way pmax bar 420 420 420 420
3-way pmax bar 315 315 315 315Nominal flow 2-way qV nom L/min 650 1000 1600 2800(∆p = 5 bar) 3-way qV nom L/min 290 460 720 1250Hysteresis, max. % < 0.2 < 0.2 < 0.2 < 0.2Repeatability % 0.2 0.2 0.2 0.2Control electronics for type .WRC VT-SR31 VT-SR32 VT-SR33 VT-SR34
Nominal size 80 100 125 160Operating pressure 2-way pmax bar 420 420 420 420
3-way pmax bar 315 315 315 315Nominal flow 2-way qV nom L/min 4350 7200 11500 18000(∆p = 5 bar) 3-way qV nom L/min 2000 3000 4500 7500Hysteresis, max. % < 0.2 < 0.2 < 0,2 < 0,2Repeatability % 0.2 0.2 0.2 0.2Control electronics for type .WRC VT-SR35 VT-SR36 VT-SR37 VT-SR38 = Preferred product range
109
Throttle valves for use in manifolds type 2/2V-CPVHigh response valves for use in manifolds type 3/2V
= Preferred product range
Proportional throttle valves, pilot operated
• Operation via a proportional solenoid
• Can be used as a pressure compensated flow controller inconjunction with a pressure compensator
• Good dynamics, low hysteresis, leak-free
• Series- With/without integrated electronics
Type 2/2-CPV
Nominal sizes 16 to 50
Detailed information:AKY013/3 Chapters 4 and 5
For control electronics see page 121
Nominal size 16 25 32 40 50
Operating pressure pmax bar 315 315 315 315 315
Nominal flow (∆p = 5 bar) qV nom L/min 125 210 320 500 980
Hysteresis, max. % < 0.2
Positioning accuracy % < 0.5
Adjustment time 0...100 % (pv = 100 bar) m/sec < 70 < 70 < 90 < 90 < 110
Operating voltage U Vnom 24
Command value signal U V 0 to 10
High response valves, pilot operatedwith electrical position feedback
• Main stage/oil flow P – A / A – T
• For use with speed and pressure closed-loop controls
• Operation via a pilot control valvetypes PL1 or HRV1
• Standard characteristic curves
• Pressure amplification 1%
Type 3/2V
Nominal sizes 25 to 50
Detailed information:AKY013/2 Chapter 12
* At 100 bar
Nominal size 25 32 50
Operating pressure pmax bar 315 315 315
Nominal flow (∆p = 5 bar) qV nom L/min 65 to 190 380 300 to 750
Hysteresis max. % ≤ 0,1
Frequency at - 90° phase response* f Hz 50 45 35
110
Proportional throttle valves type QV1-4/2WVProportional flow control valves type QV1-3WSRV
Proportional flow control valves, pilot operated• Operated via a proportional solenoid
• Series– Without closed-loop position control– With closed-loop position control– With closed-loop position control OBE
• Electronics for series without closed-loop position control– Active plug– Module– Circuit cards
• Electronics for series with closed-loop position control– Circuit cards– Integrated electronics
Proportional throttle valves, direct operated
• Operated via a proportional solenoid
• Series– Without closed-loop position control– With closed-loop position control– With closed-loop position control OBE
• Electronics for series without closed-loop position control– Active plug– Module– Circuit cards
• Electronics for series with closed-loop position control– Circuit cards– Integrated electronics
Type QV1-4/2WV
Nominal sizes 6 and 10
Detailed information:AKY013/1 Chapter 4AKY013/1 Chapter 4, page 114AKY013/1 Chapter 4, page 120
Type QV1-3WSRV
Nominal sizes 6 and 10
Detailed information:AKY013/1 Chapter 5
Nominal size 6 10
Operating pressure bar 315 315
Adjustment times 0...100%Without position control ms 70 100With position control ms 12 25
HysteresisWithout position control % ≤ 4 ≤ 5With position control % ≤ 0.3 ≤ 0.3
Qnom at ∆p 5 bar L/min 8 to 28 32 to 80
Com. value signal Standard = V 0 to +10 0 to +10also OBE with = / active plug = mA 4 to 20 4 to 20
Nominal size 6 10
Operating pressure bar 250 250
Adjustment times 0...100%Without position control ms < 70 < 70With position control ms < 35 < 35
HysteresisWithout position control % < 5 < 5With position control % < 1 < 1
Qnom L/min 7.5 to 35 65 to 100
Com. value signal Standard = V 0 to +10 0 to +10also OBE with = / active plug = mA 4 to 20 4 to 20
= Preferred product range
111
ELECTRONIC COMPONENTS, SYSTEMS ANDACCESSORIES
Electro-hydraulic control andclosed-loop systems for the:
• Control of variable displacementA4VS axial piston pumps
• Control of variable displacementA10VSO axial piston pumps
• Digital 1 and 2 axes CNC control
• Analogue and digital amplifiers in Euro-card format and of modular design
The accessory programme
• Card holders and racks
• Power supplies
• Command value cards and modules
• Pressure and position sensors
• Pressure and force controllers
• Position and speed controller (analogueand digital)
• Test units for all valves and electroniccards
• Signal transmitters
112
Amplifiers for proportional valveswithout electrical position feedback
Technical data
Operating voltage UB 24 VDC; + 40 %; – 5 %– Upper limit value uB(t)max 35 V– Lower limit value uB(t)min 22 V
Regulated voltage U M0 ± 9 V (with raised zero point)
Output amplifier Current-regulated, clocked
Connection type 32-pin blade connector, DIN 41 612,form D
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 25 to + 85 °C
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Voltage stabilisation with raised measurement zero point, filtercapacitor on the amplifier card
• Differential input, can be changed over to current input (onsome versions)
• Internal command value adjustment by means of 4 trimmingpotentiometers, call-up via relay, with LED displaye (on someversions)
• Ramp generator can be switched off
• 5 ramp times can be set using the trimming potentiometer (onsome versions)
• Step function for quickly passing the overlap on directional valves
• Clock-pulsed output stage amplifier with current regulation
• Enable input (on some versions)
• "Ready for operation" signal (on some versions)
Amplifier type Suitable for valve type
VT-VSPA1-1-1X For proportional pressure control valveswithout electrical position feedback
VT-VSPA2-1-1X/T1 1) 4WRA, NS 6 and 10 (series 2X)
VT-VSPA2-1-1X/T5 2) 4WRA, NS 6 and 10 (series 2X)
VT-VSPA2-50-1X/T1 1) 4WRZ (series 7X); DREP 6 (series 2X)
VT-VSPA2-50-1X/T5 2) 4WRZ (series 7X); DREP 6 (series 2X)
Detailed informationfor electronics:
RE 30 111
RE 30 112
RE 30 112
RE 30 113
RE 30 113
1) 1 ramp time2) 5 ramp times
= Preferred product range
113
Amplifiers for proportional valveswith electrical position feedback
• Analogue amplifiers in Euro-card format for installation in a19"rack
• Voltage stabilisation with raised measurement zero point, filtercapacitor on the amplifier card
• Differential input• Internal command value adjustment by means of 4 trimming
postentiometers, call-up via relays, with LED display (on some versions)• Ramp generator can be switched off• 5 ramp times can be set using trimming potentiometers (on
some versions)• Step function for quickly passing through overlaps on directional valves• Oscillator/demodulator for inductive position feedback• PID-controller for the closed-loop control of the control spool position• Cable break detection with LED display for the position
transducer, in the case of a cable break, the power supply to theamplifier is interrupted
• Clocked output amplifier with current regulation
Technical data
Operating voltage UB 24 VDC; + 40 %; – 5 %– Upper limit value uB(t)max 35 V– Lower limit value uB(t)min 22 V
Regulated voltage U M0 ± 9 V (with raised zero point)
Oscillator frequency f Approx. 2.5 kHz
Output amplifier Current-regulated, clocked
Connection type 32-pin blade connector, DIN 41 612,form D
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
Detailed informationto electronics:
RE 29 945
RE 30 125
RE 30 117
RE 30 117
RE 30 117
RE 30 119
RE 30 119
Amplifier type Suitable for valve type
VT 5004 2FRE, NS 10 and 16
VT-VRPD DBETR 6; 2FRE 6
VT-VRPA1-50 FE 16; FE 25; FES 25 (series 2X each)
VT-VRPA1-51 FES, NS 25 and 40 (series 3X)
VT-VRPA1-52 FES, NS 50 and 63 (series 3X)
VT-VRPA2-1 4WRE 6 (series 2X)
VT-VRPA2-2 4WRE 10 (series 2X)
= Preferred product range
114
Amplifiers for proportional valves for adjusting the flowof axial piston pumps
• Analogue amplifiers in Euro-card format for installation in 19" rack
• Voltage stabilisation with raised measurement zero point, filtercapacitor on the amplifier card
• Differential input
• IInternal command value adjustment by means of 4 trimmingpotentiometers, call-up via relays, on some versions LED display
• Ramp generator
• Ramp times can be adjusted by means of trimmingpotentiometers (on some versions separately for up/down)
• Oscillator/demodulator for inductive transducer (on some versions)
• PID-controller for the closed-loop control of the swivel angle (onsome versions)
• Cable break detection with LED display for the swivel angletransducer, in the case of a cable break, the power supply to theoutput amplifier is interrupted (on some versions)
• Clocked output amplifier with current regulation
Technical data
Operating voltage UB 24 VDC; + 40 %; – 5 %– Upper limit value uB(t)max 35 V– Lower limit value uB(t)min 22 V
Regulated voltage U M0 ± 9 V (with raised zero point)
Oscillator frequency f Approx. 2.5 kHz
Output amplifier Current-regulated, short-circuit-proof
Connection type 32-pin blade connector, DIN 41 612,form D
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for pump type
VT 3026 A4VG…EP2
VT 5035 A4VSO
VT 5041 A10VSO…DFE1
Detailed informationto electronics:
RE 30 093
RE 29 955
RE 30 240
= Preferred product range
115
Amplifiers for servo valves
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Symmetric voltage regulator (option)
• PD-controller for the closed-loop control of the valve spoolposition (on some versions)
• Freely fitted PID-controller (option)
• When controlling a pump, generally, PID-controller for theclosed-loop control of the swivel angle
• Oscillator/demodulator for inductive feedback (on someversions)
• Output amplifier with current regualtor and dither generator
Technical data
Operating pressure UB ± 22 to 28 V, smoothed
Regulated voltage U ± 15 V
Command value U ± 10 V
Oscillator frequency f Approx. 2.5 kHz / 5 kHz
Output amplifier Current-regulated
Output current I ± 60 mA / ± 100 mA
Dither frequency f 340 Hz (ISS = 3 mA)
Connection type 32-pin blade connector, DIN 41 612,form D
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
Detailed informationto electronics:
RE 29 979
RE 29 980
RE 29 993
RE 29 931
Amplifier type Suitable for valve type/pump type
VT-SR1 4WS2EE 10
VT-SR2 4WS2EM, NS 6 to 164WS2EB 104DS1EO 23DS2EH 10
VT-SR7 A4VS..HS
VT-SR31 to VT-SR38 2WRC snd 3WRC, NS 32 to 160
= Preferred product range
116
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times 0.05 to 5s
Amplifier for proportional directional valves type WV1without electrical feedback
Detailed information:AKY013/1 Chapter 13
For proportional valves see page 93
Circuit cards
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Ramp generator can be switched off
• Compensation jump
• Controlled output stage
• In and outputs are short circuit-proof
• Adjustment possibilities– Valve zero point, sensitivity– Ramp times, dither amplitude
Modular design• Compact amplifier in a plastic housing for
snapping onto a carrier rail
• Ramp generator can be switched off
• Compensation jump
• Controlled output stage
• In and outputs are short circuit-proof
• Adjustment possibilities– Valve zero point, sensitivity– Ramp times, dither amplitude
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug 13-pin screen terminals
Dimensions 85 x 110 x 75 mm
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times 0.05 to 5s
Amplifier type Suitable for valve type
2M2,5-RGC2 Proportional valves WV1 NS 6,10
Detailed information:AKY013/1 Chapter 14
For proportional valves see page 93
Amplifier type Suitable for valve type
2M45-2,5A Proportional valves WV1 NS 6,10
= Preferred product range
117
Amplifier for proportional directional valves type WV1with electrical feedback
Circuit cards
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Ramp generator can be switched off
• Compensation jump
• Controlled output stage
• Enable input
• Adjustment possibilities– Valve zero point– Sensitivity– Ramp times
• Cable brake recognition for the actual value cable
• Closed-loop position control with PID characteristics
• RGC4*– External voltage controlled ramp time adjustment via differential inputs
Detailed information:AKY013/1 Chapter 14
For proportional valves see page 93
Amplifier type Suitable for valve type
WV45-RGC2 (NS6) Proportional valves WV1 NS 6,10WV60-RGC2 (NS10) with electrical position feedback
AC position transducer
WV45-RGC4*(NS6) Proportional valves WV1 NS 6, 10WV60-RGC4*(NS10) with electrical position feedback
AC position transducer
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times 0.05 to 5s
= Preferred product range
118
Amplifier for proportional directional valves type WV2-HPP
Circuit cards
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Ramp generator can be switched off *
• Controlled output stage
• Outputs are short circuit-proof
• Enable unit
• Adjustment possibilities– Valve zero point
• Cable brake recognition for the actual value cable
• Closed-loop position control with PID characteristics
• RGC2– Externl voltage controlled ramp time adjustment via differential inputs
Detailed information:AKY013/3 Chapter 10
For proportional valves see page 96
* Only for 2STV-RGC2 withramp function
Amplifier type Suitable for valve type
2 STV Proportional directional valves WV2-HPPNS10 to 32DC position transducer
2 STV-RGC2 Proportional directional valves WV2-HPPNS10 to 32DC position transducer
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times * 0.1 to 10s
= Preferred product range
119
Amplifier for high response valves type RV
Control card
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Controlled output stage
• Enable input
• Outputs are short circuit-proof
• Adjustment possibilities– Valve zero point
• Cable brake recognition for the actual value cable
• Area compensation for differential cylinders*
• Amplification in the small signal range*
• Closed-loop position control with PID characteristics
Detailed information:AKY013/2 Chapter 16
For fast response valves see pages 94, 95and 97
Detailed information:AKY013/4 Chapter 7
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for valve type
PL6 RV1-PL1 NS6PL10 RV1-PL1 NS10PL6-AGC1* RV1-PL1 NS6, 40% inflectionPL6-AGC2* RV1-PL1 NS6, 60% inflectionPL10-AGC1* RV1-PL1 NS10, 40% inflection2STV-AGC1* RV2-PL2 NS10 to 32, 40% inflection2STV RV2-PL2 NS10 to 32, without inflectionPL6-AGC3* RV1-PL1 NS6, variable inflectionPL10-AGC3* RV1-PL1 NS10, variable inflection
= Preferred product range
120
Circuit cards for high responsne valves
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Controlled output stage
• Enable input
• Outputs are short circuit-proof
• Adjustment possiblities– Valve zero point
• Cable brake recognition for the actual value cable
• Closed-loop position control with PID characteristics
Cirucit cards for high response valves, for manifold mounting• Analogue amplifiers in Euro-card format for installation in a
19" rack
• Controlled output stage
• Enable input
• Outputs are short circuit-proof
• Adjustment possiblities– Valve zero point
• Cable brake recognition for actual value cable
• Closed-loop position control with PID characteristics
Detailed information:AKY013/2 Chapter 16
For high response valves see page 95
Amplifier for fast response valves type RV1-p/Q1Amplifier for fast response valves, for manifold mounting type 3/2V
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for valve type
5/3V pQ1
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for valve type
2STV 3/2V for fitting into manifolds
Detailed information:AKY013/2 Chapter 16
For high response valves see page 109
= Preferred product range
121
Amplifier for proportional throttle valves,for manifold mounting type 2/2V-CPV
Circuit cards
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Controlled output stage
• Enable input
• Outputs are short circuit-proof
• Adjustment possiblities– Valve zero point
• Cable brake recognition for the actual value cable
• Closed-loop position control with PID characteristics
• RGC1*– External voltage controlled ramp time adjustment via differential inputs
– Ramp switch off function
Detailed information:AKY013/3 Chapter 10
For proportional throttle valves see page 109
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times* 0.1 to 10s
Amplifier type Suitable for valve type
2/2V NS16 to 50 CPV
2/2V-RGC1* NS16 to 50 CPV
= Preferred product range
122
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times 0.05 to 5s RGC3 0.1 to 10s adjustable
Amplifier for proportional pressure relief valves type PV1/2-DBVAmplifier for proportional pressure control valves type PV2-DRV
Circuit cards
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Controlled output stage
• Enable input (partially)
• Compensation jump
• In and outputs are short circuit-proof (partially)
• External ramp can be switched off*
• Adjustment possiblities– Valve zero point– Ramp times (if the ramp time function is available)
• RGC3– External voltage controlled ramp time adjustment via differential inputs
Detailed information:AKY013/1 Chapter 14
For proportional pressure valves see page 104
*With ramp
Amplifier type Suitable for valve type
1M45-0,8A* PV1-DBV without position controlPV2-DBV without position controlPV2-DRV without position controlPV2-DRV-3W
1M45-2,5A* PV1-DBV without position controlPV2-DBV without position control
PV45 PV2-DRV-3W LVDT-ACPV45-RGC1* PV2-DRV-3W LVDT-ACPV45-RGC3* PV2-DRV-3W LVDT-ACPV60 PV1-DBV LVDT-AC
PV2-DBV LVDT-ACPV2-DRV-3W LVDT-AC
PV60-RGC1* PV1-DBV LVDT-ACPV2-DBV LVDT-ACPV2-DRV-3W LVDT-AC
PV60-RGC3* PV1-DBV LVDT-ACPV2-DBV LVDT-ACPV2-DRV-3W LVDT-AC
PDL1 PV1-DBV linear LVDT-ACPDL1-RGC1* PV1-DBV linear LVDT-ACPDL1-RGC3* PV1-DBV linear LVDT-AC
= Preferred product range
123
Circuit cards
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Controlled output stage
• Enable input (partially)
• Compensation jump
• In and outputs are short circuit proof (partially)
• External ramp can be switched off*
• Adjustment possibilities– Valve zero point– Ramp times (if the ramp time function is available)
• RGC3– External voltage controlled ramp time adjustment via differential inputs
Amplifier for proportional throttle valvesand proportional flow control valves type QV
Detailed information:AKY013/1 Chapter 14
For proportional throttle andflow control valves see page 110
*With ramp
Amplifier type Suitable for valve type
1 M 45 – 2,5A* QV1 – 4/2WV without position controlQV1 – 3W SRV without position control
QV 45 QV1 – 4/2WVQV 45 – RGC1* LVDT-AC 2,7A solenoidQV 45 – RGC3* QV1 – 3W SRV
LVDT-AC 2,7A solenoidQV 60 QV1 – 4/2WVQV 60 – RGC1* LVDT-AC 3,7A solenoidQV 60 – RGC3* QV1 – 3W SRV
LVDT-AC 3,7A solenoid
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Valve switching times 50ms at 100% signal jump
Ramp times* 0.05 to 5s RGC3* 0.1 to 10s adjustable
= Preferred product range
124
Pressure and differential pressure controllers
Circuit card
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Cable break recognition for the actual value cable,position/pressure transducer (with the exception of Diff-p/Q)
• External controller switch-off
• Pressure sensor connections (1 to 6 V/0 to 10 V,4 to 20 mA)
• Controller with valve amplifier– Controlled output stage– Enable input– Short circuit-proof outputs
Detailed information:AKY013/4 Chapter 5
For high response valves see page 95
*No connections for 1 to 6 V pressuresensors
Amplifier type Suitable for valve type
PL6-PQI RV1-NS6PL10-PQI RV1-NS105/3V-PQI PQ12STV-PQI RV2PQI-1 Without valve amplifierPQI-1/2 Without valve amplifier (2 channel)Diff-PQ* Without valve amplifier
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
= Preferred product range
125
Analogue amplifiers of modular design
• Compact amplifiers in plastic housings for snapping onto carrierrails according to DIN 50 022
• DC/DC convertor for internal voltage supply; filter capacitor mustbe connected externally in the incoming circuit (on some versions)
• Differential input
• Ramp generator (on some versions)
• Step function for quickly passing through overlaps on directionalvalves
• Oscillator/demodulator for inductive position feedback (on someversions)
• PI-controller for the closed-loop control of the control spoolposition (on some versions)
• Clocked output amplifier with current regulator
Technical data
Operating voltage UB 12 V; +30%; –10% 24 V; +40%; –10%– Upper limit value uB(t)max 16 V 35 V– Lower limit value uB(t)min 10.5 V 21,5 V
Command value U ± 10 VOutput amplifier Current-regulated, clockedConnection type Screw terminalsModule dimensions 79 x 85.5 mm (height x depth)Permissible ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
Detailed informationto electronics:
RE 30 226RE 29 728RE 29 762RE 29 762RE 29 760RE 29 737RE 29 743RE 29 751RE 29 741RE 29 741RE 29 764RE 29 774RE 29 756RE 29 758RE 30 218RE 29 865RE 29 870RE 29 866RE 30 219RE 30 219
Amplifier type Suitable for valve type
VT 11004, VT 11015 and VT 11026 DRE 4 K (24 V)VT 11007 and VT 11016 DRE 4 K (12 V)VT 11008 and VT 11017 FTDRE 2 K (24 V)VT 11009 and VT 11018 FTDRE 2 K (12 V)VT 11010 and VT 11031 DRE 4 K (12 V or 24 V)VT 11011 and VT 11012 For prop. directional and pressure valvesVT 11021 4WS2E. 10VT 11025 DBETR 6VT 11029 1 proportional solenoid - 100 Hz (pumps)VT 11030 1 proportional solenoid - 200 Hz (z.B. DBE)VT 11032 and VT 11165 DRE 4 K (24 V)VT 11033 and VT 11034 2FRE, NS 6 to 16VT 11037 FES 25 CVT 11076 to VT 11079 4WRK, NS 10 to 32VT 11118 4WRZ (from series 5X)VT 11131 and VT 11132 For proportional pressure control valvesVT 11550 to VT 11554 DRE 4 K (+ 3WE 4)VT 11724 For proportional pressure reducing valvesVT-MRPA2-1 4WRE 6 (series 2X)VT-MRPA2-2 4WRE 10 (series 2X)
= Preferred product range
126
Amplifier for proportional pressure relief valves type PV1/2-DBVAmplifier for proportional pressure control valves type PV2-DRV
Modular design
• Compact amplifier in a plastic housing forsnapping onto a carrier rail
• Ramp generator can be switched off
• Compensation jump
• Controlled output stage
• In and outputs are short circuit proof
• Adjustment possiblities– Valve zero point– Sensetivity– Ramp times– Dither amplitude
Detailed information:AKY013/1 Chapter 13
For proportional pressure control andpressure relief valves see page 104
*With ramp
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug 10-pin screw terminals
Dimensions 86 x 110 x 75 mm
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times 0.05 to 5s
Verstärkertyp geeignet für Ventiltyp
1M 0,8-RGC1* PV1/2-DBV without position controlPV1/2-DRV without position control
1M 2,5-RGC1* PV1/2-DBV without position control
= Preferred product range
127
Amplifier for proportional throttle valvesand proportional flow control valves
Modular design
• Compact amplifier in a plastic housing forsnapping onto a carrier rail
• Ramp generator can be switched off
• Compensation jump
• Controlled output stage
• In and outputs are short circuit proof
• Adjustment possiblities– Valve zero point– Sensetivity– Ramp times– Dither amplitude
Detailed information:AKY013/1 Chapter 13
For proportional throttle andflow control valves see page 110
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug 10-pin screw terminals
Dimensions 86 x 110 x 75 mm
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Ramp times 0.05 to 5s
Amplifier type Suitable for valve type
1M 2,5-RGC1 QV1-4/2WV without position controlQV1-3W-SRV without position control
= Preferred product range
128
Circuit card position controller
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Point-to-point position control
• Interface analogue to CNC control
• Adjustment possibilities– Zero point position transducer– Amplifier position transducer– Speed– Internal position command values
Position controllerPosition and speed controller
Detailed information:AKY013/4 Chapter 6
Technical data
Operating voltage UB Nominal 24 VDC (21 to 34 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for valve type
APC3-SVZ Without valve amplifier
Modular design, position and speed control
• Control of 0 to 10/+ -10 V and 4 to 20 mA valves
• Enable input
• Cable break recognition for the actual value cable
• Interfaces are short circuit-proof
• Test points on the front plate
• Compensation jump can be switched off
• Position: PT1 control
• Speed: PI control
• Cylinder area relationship calibration
Technical data
Operating voltage UB 24 VDC (21 to 40 V smoothed)
Connection type Plug 13-pin screw terminals
Dimensions 86 x 110 x 95 mm
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for valve type
AVPC-V Without valve amplifierControl 0 to 10 V/+ - 10 V
AVPC-mA Without valve amplifierControl 4 to 20 mA
Detailed information:AKY013/4 Chapter 6
= Preferred product range
129
• Analogue command value card for controlling valves withintegrated electronics
• Suitable for generating, linking and normalising command valuesignals
• Configuration and parameterisation of the command value cardis via potentiometers
• Inversion of the internal command value signal via the 24V inputor jumper
• Ramp time selection via quadrant recognition(24V input) or ramp time call-ups (24V inputs)
• Switching the ramp time range via jumpers
• Characteristic curve correction via separate, adjustable jumpchanges and maximum values
• Enable input
Technical data
Operating voltage UB 24 VDC + 40 % – 20 %
Input voltages (analogue):– Command value 1 to 4 (poti-inputs) Ue 0 to ± 10 V– Command value 5 (differentail input) Ue 0 to ± 10 V– Command value 6 (differentail input) Ie 4 to 20 mA
Output signals (analogue):– Adjustment variable
• Voltage U ± 10 V ± 2 %; Imax = 2 mA• Current I 4 mA to 20 mA ± 2 %
– Measurement signal U ± 10 V ± 2 %; Imax = 2 mA
Connection type 48-pin blade connection, DIN 41 612,form F
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible ambient temperature range ϑ 0 to + 50 °C
Storage temperature range ϑ – 25 to + 85 °C
Analogue command value card VT-SWKA-1
Detailedinformation:RE 30 255
Electronic type
VT-SWKA-1 Command value card
= Preferred product range
130
Analogue command value modulesAccessories of modular design
Type of electroncis
VT 11003 Switching amplifier module for directional valvesOperating voltage: 10 to 24 VDCOutput voltage: UB – 2.5 V
VT 11005 Power supply moduleOperating voltage: 10 to 12 VDCOutput voltage: ± 15 VDC; 200 mA
VT 11006 Power supply moduleOperating voltage: 20 to 24 VDCOutput voltage: ± 15 VDC; 200 mA
VT 11027 and Relay module with one make contact,VT 11028 smoothing capacitor and overvoltage protection
VT 11073 Capacitor module with smoothing capacitor, reversepolarity and overvoltage protection
Detailedinformation:
RE 29 731
RE 29 732
RE 29 729
RE 29 742
RE 29 750
General accessories of modular design
Assemblies in plastic housing for snapping ontocarrier rails to DIN 50 022
VT-SWMA-1 and VT-SWMAK-1 analogue command valuemodules
• For controlling valves with inegral electronics
• Possibility of implementing simple hydraulic functions throughdigital controls
• Differential input
• Actuating signal output
• Power supply unit without raised zero point
• Without power part
Detailedinformation:
VT-SWMA-1 command value moduleRE 29 902
VT-SWMAK-1 command value moduleRE 29 903
Technical data
Operating voltage UB ± 24 VDC
Command value U ± 10 V
Output signal (control variable) U 0 to ± 10 V
Type of connection Screw terminalsModule dimensions 79 x 85.5 mm (height x depth)Permissible ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
= Preferred product range
= Preferred product range
131
• Digital amplifiers in Euro-card format for installation in a 19" rack
• Amplifier type that can be used for a multitude of valves(programmable)
• Use of a powerful microcontroller
• Analogue command value input as voltage or current input
• Ramp time with 2 rounding times for start and end
• Free programmability of output stage frequency, biasing, surgeand final current or current characteristic curve with max. 8interpolation points
• 16 command value call-ups with ramp times, call-up via digitalinputs
• Sequence control is possible
• Variable gain and offset correction for command value input
• LED function displays; measuring sockets for command and actual value
• Non-volatile storage of programmed data in an EEPROM
• Clocked, current-regulated output stages
• Switched-mode power supply pack for internal supply voltages
• Configuration, parameterisation and diagnosis via serial interface
Technical data
Operating voltage UB 24 VDC + 40 % – 10 %– Upper limit voltage uB(t)max 35 V– Lower limit voltage uB(t)min 21 V
Current consumption Imax 2.3 A (depending on the selected valve)
Digital inputs U log 0 = 0 to 2 Vlog 1 = 15 V to UB
Analogue inputs (Re = 100 Ω) U ± 10 VI ± 20 mA, 4 to 20 mA or 0 to 20 mA
Nominal solenoid resistance (20 °C) R 2 to 20 ΩOutput current I 0 to 2.5 A (clocked)
Clock frequency of output stage f 100 to 1000 Hz
Scanning rate T 0.3 ms
Ramp time tmax 100 s
Serial interface RS 485 (front panel and plug-in connector)
Connection type 48-pin blade connector, DIN 41 612,form F
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible operating temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
VT-VSPD-1digital amplifiersfor proportional valves without electrical position feedback
Detailedinformation:
RE 30 123
RE 29 798RE 29 794RE 29 899
Type of electronics
VT-VSPD-1 For controlling proportional valves withoutelectrical position feedback
For parameterisation:VT 12321 BB-3 hand-held control boxVT 12323 BF-1 control panelSYS-DigVen-BODIV-01 PC programme BODIV = Preferred product range
132
• Digital amplifiers in Euro-card format for installation in a 19 " rack• Presetting of all parameters
– With VT-VRPD-1 for the following valves:4WRE, NS 6 and 10 (series 1X)DBETR (series 1X); FES 25 (series 2X);2FRE 6 (series 2X); 2FRE, NS 10 and 16 (series 4X)
– With VT-VRPD-2 for the following valves:4WRE, NS 6 and 10 (series 2X)
• Use of a powerful microcontroller• Analogue command value input as voltage or current input• Voltage input as differential input• Variable gain and offset correction for command value input• Ramp generator• Sequence control and overlap compensation possible• Digital inputs for calling up preset command value parameters• Enable input and error output• Switched mode power supply pack for internal supply voltages• LED function displays; measuring sockets and command and
actual value• Standardised connector strip assignment• Configuration, parameterisation and diagnosis via serial
interface
Technical data
Operating voltage UB 24 VDC + 40 % – 10 %– Upper limit voltage uB(t)max 35 V– Lower limit voltage uB(t)min 21 VCurrent consumption Imax 2.3 A (depending on the selected valve)Digital inputs U log 0 = 0 to 2 V
log 1 = 15 V to UB
Analogue inputs (Re= 100 Ω) U ± 10 VI ± 20 mA, 4 to 20 mA or 0 to 20 mA
Nominal solenoid resistance (20°C) R 2 Ω to 12.7 ΩOutput current Imax 1.3 A to 2.5 A (clocked)Clock frequency of output stage f 190 Hz to 4.3 kHzOscillator frequency f 2.5 kHz to 7.8 kHzScanning rate T 0.3 msRamp time tmax 100 sSeriel interface RS 485 (front panel and plug-in connector)Connection type 48-pin blade connector, DIN 41 612,
form FCard dimensions Euro-card 100 x 160 mm, DIN 41 494Permissible operating temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
VT-VRPD digital amplifierfor proportional valves with electrical position feedback
Type of electronics
VT-VRPD-1 and VT-VRPD-2 For controlling direct operated proportional valveswith electrical position feedback
For parameterisation:VT 12321 BB-3 hand-held control boxVT 12323 BF-1 control panelSYS-DigVen-BODIV-01 PC programme BODIV
Detailedinformation:
RE 30 125
RE 29 798RE 29 794RE 29 899 = Preferred product range
133
• Digital assemblies in Euro-card format for installation in a 19"rack
• Use of a powerful microcontroller
• Analogue inputs and outputs optionally as voltage or currentinterface
• Variable gain and offset correction for each analogue input
• Controllers, ranp generator(s)
• Characteristic curve correction or characteristic curvelinearisation
• Possibility of sequence control
• Digital inputs for calling up preset command value parameters
• Enable input and error output
• Switched mode power supply pack for internal supply voltages
• Configuration, parameterisation and diagnosis via serialinterface
Technical data
Operating voltage UB 24 VDC + 40 % – 10 %– Upper limit voltage uB(t)max 35 V– Lower limit voltage uB(t)min 21 V
Current consumption Imax 350 mA
Digital inputs U log 0 = 0 to 2 Vlog 1 = 15 V to UB
Analogue inputs (Re=100 kΩ) U ± 10 VI ± 20 mA, 4 to 20 mA or 0 to 20 mA
Analogue outputs U ± 10 V (RL min = 1 kΩ)I ± 20 mA, 4 to 20 mA or 0 to 20 mA
(RL = 100 to 500 Ω)
Scanning rate T 0.5 ms
Ramp time tmax 100 s
Seriel interface RS 485 (front panel and plug-in connector)
Connection type 48-pin blade connector, DIN 41 612,form F
Card dimensions Euro-card 100 x 160 mm, DIN 41 494
Permissible operating temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
VT-SWKD-1 digital command value cardsVT-SWKD-2 digital controller cards
Detailedinformation:
RE 30 121
RE 30 122
RE 29 798RE 29 794RE 29 899
Type of electronics
VT-SWKD-1 For generating, interlinking and normalising commandvalue signals as well as for simpler controller applications
VT-SWKD-2 For closed-loop position controls, as matching electronicsfor NC controlled axes or as a substitue for VT-PVAR2analogue closed-loop control electronics
For parameterisation:VT 12321 BB-3 hand-held control boxVT 12323 BF-1 control panelSYS-DigVen-BODIV-01 PC programme BODIV
= Preferred product range
134
VT-HNC100 digital axis control
• Can be used optionally as freely programmable NC control, asNC control with fixed command value sets or as digital position/pressure controller for one or two axes
• Freely configurable controller variants:– Position controller (PDT1) with zero point compensation
(integration principle), residual voltage principle for proportionalvalves with positive overlap, command value feed-forward andstate feedback
– Position-dependent braking to target position– Pressure/force controller (PIDT1) with differential pressure
evaluation and own scanning rate
• Operating modes: Set-up or automatic
• The measuring systmes used can be either analogue, incrementalor absolute (SSI) encoders for position sensing or analoguepressure/force transducers
Type of electronics
VT-HNC100 Point-to-point control for hydraulic drives
Consisting of: 19" Euro-card in aluminium housing,suitable for installation in 19" rack or forwall mounting
Applications: • Presses• Plastics processing machines• Machine tools• Transfer machines• Special machines
VT-HNC100DEMO Controlled system simulator for VT-HNC100with PC software WIN-PED • For getting familiar with the functions of the digital
VT-HNC100 axis control• Simulation of a hydraulic controlled system with
change-over between high and low natural frequency
Detailedinformation:
RE 30 131
Programming and system integrationas programmable NC control
Programming:• User programming via PC (Windows 9X or Windows NT)• NC language with subroutine technique and conditional jumps• Own NC programme for function sequences („WIN-PED“)
Operation:• Convenient data administration on a PC• Data can be quickly changed using the BB-3 control box or BF-1 control panel
Process interfacing:• 8 or 24 digital inputs and outputs each, Profibus DP, CANopen
or INTERBUS-S for communicating with a PLC
Hydraulic axes:• Measuring system
– Incremental or absolute (SSI)– Analogue 0 to ± 10 V and 4 to 20 mA– Reference voltage ±10 V
• Control variable output ± 10 V or 4 to 20 mA• Freely configurable controller variants
– Position controller; pressure/force controller– Position-dependent braking– Alternating closed-loop control (position/pressure)
RE 30 133
= Preferred product range
135
HNC100-SEK digital controller assemblyfor secondary control of axial piston units
• Digital controller assembly with software for open and closed-loop control and monitoring functions tailored to secondarycontrol
• Assembly in HF tight housing for wall mounting or as plug-inunit for 19" rack
• Non-volatile storage of system parameters in an EEPROM
• Parameterisation and process visualisation using a commerciallyavailable PC
• Two modules with monitoring function for evaluating signalsprovided by inductive swivel angle transducers
• Configured sequence routing for on/off sequence withcontrolling of isolator valve and possible existing brake
• Monitoring functions with error code output to simplifydiagnosis
Technical data
Operating voltage UB 18 to 36 VDC
Analogue inputs 4 differential inputs (voltage or current)4 impedance convertor inputs
Analogue outputs 2 voltage or current outputs and2 voltage outputs
Signal inputs 24 digital inputs
Signal outputs 24 digital outputs
Serial interfaces Standard RS 232 (for communication programme)Optional Profibus DP (9.6 KBaud)On request CANopen, INTERBUS-S
Dimensions of version forwall mounting (W x H x D) 106.5 x 155 x 204 mm
Permissible ambient temperature range ϑ 0 to + 50 °C
Storage temperature range ϑ – 20 to + 70 °C
Type of electronics
SYHNC100-SEK Digital controller assembly for closed-loop speed andtorque control and open-loop torque control of secondarycontrolled A4VS..DS1(E) axial piston units
Accessories:WIN-PED PC programme for communicating with the digital
HNC100-SEK controller assemblyKABELSATZ VT15300 Connecting cable between PC and HNC100-SEK
Detailedinformation:
RE 30 141
= Preferred product range
136
IP252mH controller assembly for direct usein SIMATIC-S5 and SIMATIC-S7-400 systems
Programming and system integration
• Use in the automation units SIMATIC S5-115U, S5-135U,S5-155U and S7-400
• Convenient communications programme "COM252M" (MS-DOS)with the following features:– Commissioning and diagnosis functions– Controller configuration– Project data administration– NC sequence programming– Graphical measured data evaluation
• NC language in line with DIN 66 025, max. 2000 NC sets• Extended NC command set for closed-loop pressure control, monitioring functions,
switching between open/closed-loop controlled traversing• Data exchange with the automation unit via standard function blocks• With VT16000, hardware adjustment to the individual customer application by means
of up to 4 plug-in peripheral modules:– Combination module with 8 analogue inputs and 4 analogue outputs– Counter module for 2 incremental linear and/or rotary encoders– SSI module for 4 absolute value encoders with SSI interface– Digital module with 8 digital inputs and 8 digital outputs
• With VT16005, two firmly installed peripheral modules:– Combination module with 4 analogue inputs and 2 analogue outputs– SSI module for 2 absolute value encoders with SSI interface
• Digital control for up to 4 hydraulic axes
• Freely configurable controller variants:– Position controller (PDT1) with zero point compensation
(integration principle), fine positioning with step function forproportional valves with positivie overlap, command valuefeedforward and state feedback (velocity, acceleration,pressure)
– Position-dependent braking to target position with velocitycharacteristic curve adjustment
– Synchronism controller (PI) according to the master-slaveprinciple or the average value principle
– Pressure/force controller (PIDT1) with differential pressureevaluation
• Switching mechanism with 32 inter-axis switching points
• The measuring system used can be either analogue, incrementalor absolute (SSI) encoders for position sensing or analoguepressure/force transducers
Detailedinformation:
RE 29 788-PRE 29 788-P
Type of electronics
VT 16000 (IP252mH) Point-to-point control for up to 4 hydraulic axesVT 16005 (IP252mH) Point-to-point control for up to 2 hydraulic axes
Applications: • Presses• Plastics processing machines• Machine tools• Transfer machines• Special machines
= Preferred product range
137
Branch electronics, machine tools,nibbling/stamping
Circuit card
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Controlled output stage*
• Enable input*
• Outputs are short circuit-proof*
• Adjustment possibilities*– Valve zero point
• Area calibration for differential cylinders*
• Amplification in the small signal range*
• Position control with PID characteristics*
• Cable break recongition for the actual value cable
Amplifier type Suitable for valve type
PL6-AGC1* RV1-PL1 NS6 with inflectionPL6-AGC2* RV1-PL1 NS6 with inflectionPL6-AGC3* RV1-PL1 NS6 with inflectionPL10-AGC1* RV1-PL1 NS10 with inflectionPL10-AGC3* RV1-PL1 NS10 with inflection2STV-AGC1* RV2-PL2 NS10 to 32 with inflectionAPC2-LVAR-HRV Without valve amplifier
Application: Nibbling/stamping
Technical data
Operating voltage UB Nominal 24 VDC (21 to 40 VDC)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Detailed information:AKY013/4 Chapter 7
AKY013/4 Chapter 9
= Preferred product range
138
Branch electronics
Circuit card, plastics machines
• Analogue amplifiers in Euro-card format for installation in a19" rack
• Injection process control card for controlling the injection sidefunctions of plastic injection moulding machines
• Separate controllers for– Injection time– After pressure– Back pressure during plastification
• For integration into the machine concept
• Control via a PLC is possible
• Without valve amplifier
Detailed information:AKY013/4 Chapter 8
Technical data
Operating voltage UB 24 VDC (21 to 40 V smoothed)
Connection type Plug DIN 41 612-F32
Card dimensions Euro-card 100 x 160 mmwith front plate 7TE
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Amplifier type Suitable for valve type
SPR2-VLRC 4/4 high response valves
SPR3-VLRD 4/5 high response valves withde-compression setting
= Preferred product range
Circuit card, digital position controller
• Digital closed loop position controller, fixed command value sets
• 19” rack• For controlling from 0 to +/–10 V valves
• Versions for:– Analogue position measuring systems (ultrasonic, potentiometer)– Digital position measuring systems (SSI, Incremental)– Multi axis closed loop control (Sync) for up to 4 axis
Technical data
Operating voltage UB Nom. 24V DC (18 to 30V with a residual ripple <5%)Polarity protection for the power supply connections
Current consumption max. 300 mA at UB = 20V DC
Connection type Plug DIN 41 612-F48
Card dimensions Euro card 100 x 160 x 50,8with a 10TE front plate
Ambient temperature range ϑ 0 to + 50 °CStorage temperature range ϑ – 20 to + 70 °C
Detailed information:AKY013/4 Chapter 6
Typ DPCD-(SYNC) – without valve amplifiers
Typ DPCA-(SYNC)Gehäuse zu DPC
139
Electronics for testing technology
• Modular HydroControl electronics for solving standardisedtesting tasks
• IBM compatible PC with PC plug-in card and software for thepreselection of command values of load cycles and simpleaquisition of measured data
• Closed-loop control and monitoring electronics as well assupplementary electronic assemblies
• Controlling by PLC possible
Control and instrumentation, software
Type
VTS 0985 PCE 5 PC plug-in board
VTS 0325 LWK 2.0 software package for load cycles
HYVOS 4.0 simulation of valve-controlled linear drives
Closed-loop control and monitoring electronics
Type
Closed-loop control electronics for testing and simulation
SY-HCE-1 HCE 1 HydroControl electronics
VT-KU-1 KU 1 communication and monitoring unit
VTS 0404 BK 1 measuring socket card
VT-BK-2 BK 2 measuring socket card with anti-aliasing filter
VTS 0161 TF 6207 carrier frequency measuring amplifier
VTS 0162 TF 6208 carrier frequency measuring amplifier
VTS 0615 SR 91 amplifier for servo valves with electricalposition feedback
VTS 0616 SR 92 amplifier for servo valves without electricalposition feedback
VTS 0617 SR 98 amplifier for servo valves without electricalposition feedback
RE 57 803
RE 57 900
RE 57 841
RE 57 725
RE 57 726
RE 57 721
RE 57 722
RE 57 850
RE 57 851
RE 57 852
Detailedinformation:
RE 57 881
RE 57 780
RE 30 810
= Preferred product range
140
• Control and instrumentation equipment tailored to therequirements of stages and studios; corresponds to requirementclass 5 to DIN 19 250
• Due to the modular design, the equipment can be adapted tothe demands of large and small systems
• Multi-axis and multi-master system
• Real time operating system based on the 68360 hardware byMotorola (software can be ported to future hardware)
• Application-specific MR10 data bus with patented, variableband width allocation
• High availablity due to decentralised system structure
• Optimum operating comfort due to touch screen
• Recording of operating profiles; interlinking of movements; slewmovements of ceilings
• Controlling of other systems via "external outputs"(e.g. special stage sets)
• Movements can be triggered by other systems via "externalinputs" (e.g. synchronisation of light and sound effects)
• Input of all operating parameters and storage of all groupoperations of the performance on floppy or hard disk
• Simulation of performances
• Automatic saving and archiving of operating data
• Remote diagnosis via modem
Safety-relevant control and instrumentation technology SYB 2000for use in theatre applications
Technical data
Scanning rate 10 ms
Network 10 MBit/s(with variable bank width allocation)
Error response time ≤ 20 ms
Synchronisation accuracy ± 1 mm
Valve control Single and dual channel
Number of operational groups Max. 16 (simultaneously)
Number of MR10 bus stations 256
Speed range 2 mm/s to 1800 mm/s
Type of electronics
SYB 2000 • Depending on the drive the axis controllers (AC) can controland monitor 1 to 4 axes per drive.
• The master controller (MC) co-ordinates the individual ACs, providesoperating commands for the axis groups, forms the interfaces with theoperator computers and assums monitoring functions.
• The control panels (SC) are provided with a colour screen (TFT)and a touch screen system (optionally with mouse or trackball).
• The bus master (BM) co-ordinates the bus access of stationswithin the network. The patented bus protocol MR10 allows theconnection of 256 stations; 80 stations can operatesimultaneously in real time.
• The data controller (DC) is used as a system data memory(e.g. synchronous groups).
Detailedinformation:
On request
= Preferred product range
141
Control and automation technology for hydraulicinstallations and systems
• Electro-hydraulic systems from a single source
• From the specification through to the finished system
• Complete equipment, including:– Design, installation and commissioning– Software– Maintenance / service
• Complete concept:– Power electrics– Programmable logic controls– Visualisation systems
• Minimisation of interfaces, site co-ordination
• Comprehensive documentation on CAD and programming systems
Control and automation technology for hydraulic systems
Fields of application
• Steelwork / rolling mill technology• Press construction and general mechanical engineering• Test rig technology• Shipbuilding and offshore applications• Material handling• Theatre technology• Energy and environmental technology• Civil engineering• Special technology
Detailed information:
On request
= Preferred product range
142
Closed-loop control systems, types SYDFE1, SYDFEE and SYDFEC, forcontrolling A10VSO axial piston pumps
Closed-loop control systems for controlling A10VSOvariable displacement axial piston pumps
• Infinitely variable closed-loop control of flow and pressure
• Additional power limitation possible
• High reproducibility of flow and pressure due to closed-loopcontrol
• Dynamics of closed-loop flow control correspond to closed-loopcontrol with proportional valves due to short adjustment timesof the pump
• Pressure controller can be matched to the actuator by means ofjumper settings
• Avoidance of throttling losses through central closed-loop flowand pressure control (energy saving)
• Integrated control electronics for type SYDFEE
SYDFE1, SYDFEE and SYDFEC closed-loop control systems
System design: • A10VSO variable displacement axial piston pump with built-onproportional valve including inductive position transducer
• HM 12 or HM 13 pressure transducer• SYDZ 0001 perload valve• VT 5041 controller card (for SYDFE1 only)
with power limitation and swivel angle indicator
Applications: • Plastics processing machinery• Presses• Crane systems• Broaching machines• Shipbuilding• Construction machines
Pump nominal size 45 71
Operating pressure pmax bar 250 250
Nominal flow (n = 1500 min –1) qV nom L/min 68 107
Step response of swivel 0 to 100 % Tu+Tg ms 65 70angle control (50 bar) 100 to 0 % Tu+Tg ms 35 40
Pump nominal size 18 28
Operating pressure pmax bar 250 250
Nominal flow (n = 1500 min –1) qV nom L/min 27 42
Step response of swivel 0 to 100 % Tu+Tg ms 60 65angle control (50 bar) 100 to 0 % Tu+Tg ms 35 35
Pump nominal size 100 140
Operating pressure pmax bar 250 250
Nominal flow (n = 1500 min –1) qV nom L/min 150 210
Step response of swivel 0 to 100 % Tu+Tg ms 80 100angle control (50 bar) 100 to 0 % Tu+Tg ms 45 60
Types SYDFE1, SYDFEE und SYDFEC
Pump nominal sizes 18 to 140
Detailed information:• RE 30 024 (type SYDFE1)• RE 30 027 (type SYDFEC)• RE 30 030 (type SYDFEE)
= Preferred product range
143
MX4 multi-axes CNC control
• Point-to-point/continuous path control for hydraulic systemswith 2 to 32 axes
• Position controller:– Position-dependent braking– Follow-up controller– State controller– Synchronisation controller– Follow-up controller for several axes– Velocity controller– Force/differential pressure controller
• Programming:– Up to 16 parallel programmes– PLC functions– Comprehensive debugger
• Visualisation, parameterisation using an industrial PC, terminal,BB-3 control box or control panel BF-1
• The measuring systems used can be either analogue, incrementalor absolute (SSI) encoders for position sensing or analoguepressure/force transducers
Programming and system integration
• Programming and debugging by means of MX4 programming software is possible onany PC
• Programmes and parameters can be saved in the RAM or EPROM of the MX4• 1 MB RAM for programme and data per axis card• Time-optimised execution due to compilation of the NC programme in the machine
code• 16 parallel NC programmes (multi-tasking)• High-level language-oriented NC language• Convenient debugger with programme tracing, single step execution, brake points, etc• Availabale as stand-alone system or:
– Operation by means of BB-3 control box or BF-1 control panel– Terminal can be programmed by means of dialogue commands– Visualisation on indstrial PC
• Profibus-DP interfacing, Interbus-S-Slave interfacing
Type of electronics
MX4 Point-to-point/continuous path control for up to 32axes made up from hardware components in Euro-formataccording to the modular axes
Consisting of: • MTCB02/MTCB03 rack• AM2 or AM4 axis mater card• AX2 or AX4 axis slave card• DEAB02 I/O card
Applications: • Presses• Plastics processing machines• Steelworks and rolling mill technology• Material handling• Automotive industry• Shipbuilding• Test rig technology• Special machines
Detailedinformation:
On request
= Preferred product range
144
Pressure transducers and pressure displays
• For the measurement of static or dynamic pressures and theconversion of the measured values into electrical signals andtheir representation
• Pressure transducers HM 12 to HM 15:– Full bridge made of semiconductor strain gauges as
measuring element– Integrated voltage regulator with reversed polarity and
overvoltage protection– Measuring amplifier with voltage or current output
• Pressure displays HM 2, HM 3 and HM 5– Evaluation electronics with analogue output– 3-digit LED display– Supply voltage for pressure transducer (HM 5 only)– Potential-free limit value contacts (HM 3 only)– Standarised housing for control panel installation
• Pressure switch HM 10– Pressure transducer– Display unit– Monitoring electronics with 4 adjustable switching levels and
adjustable hysteresis
Technical data - pressure transducer
Type HM 12 HM 13 HM 14 HM 15
Operating voltage UB 10 to 30 V 10 to 30 V ± 12 V 10 to 30 V
Accuracy class 0.5 0.5 0.5 0.5
Output signal U/I 4 to 20 mA 0 to 10 V 0 to 10 V 4 to 20 mA
Pressure range p 250 to 250 to 10 to 10 to400 bar 400 bar 600 bar 600 bar
Detailed information:
HM 12 and HM 13 pressure transducersRE 29 933
HM 14 and HM 15 pressure transducersRE 29 932
Technical data - pressure displays
Operating voltage UB 110 / 220 VAC
Input signal– HM2, HM3 I 4 to 20 mA– HM5 U 0 to 10 V
Analogue output U 0 to 10 V; 5 mA
Pressure range p 10 to 600 bar (630 bar)
Permissible ambient temperature range ϑ 0 to 50 °C
HM 2 pressure displayRE 29 973
HM 3 pressure displayRE 29 974
HM 5 pressure displayRE 29 975
HM 10 pressure switchRE 29 968
Technical data - pressure switch
Operating voltage UB 24 VDC; ± 10 %– Upper limit value uB(t)max 27 V– Lower limit value uB(t)min 22 V
Accuracy class 0.5
Output signal U 0 to 10 V
Relay data 250 V; 2 A; 400 VA; 50 W
Pressure range p 10 to 450 bar
Permissible ambient temperature range ϑ 0 to 50 °C = Preferred product range
145
Technical data
Operating voltage UB 18 to 32 V
Accuracy class 0.5
Output switch I Non-floating open collectorto UB; ≤ 1 A
Pressure range p 100 to 350 bar
Fluid temperature ϑ – 10 to + 80 °C
Pressure sensor• For measuring static or dynamic pressures as well as converting
the measured values into electrical signals– The pressure sensing element comprises of a stainless steel
membrane which is coated with a thin film strain tensor as afull bridge circuit
– Integrated electronics with temperature compensation– The signal output is proportional to the pressure– Zero point and sensitivity are precisely calibrated– 3 different plug types
Pressure sensorsElectrical pressure switches
Electronic pressure switch• For converting a pressure signal into an electrical switching
signal– The sensor element comprises of a stainless steel
membrane– 2 switching points which can be individually adjusted– Adjustable damping time– System pressure display– Transistor switched output– 2 different plug types
Technical data
Operating voltage UB 14 to 28 V
Accuracy class 0.5
Output signal (alternative) U/I 0 to 5 V, 0 to 10 V; 1 to 6 V; 4 to 20 mA
Pressure range p 60 to 350 bar
Operating temperature range ϑ – 10 to + 80 °C
Detailed information:Pressure sensors AKY013/4 Chapter 1Plug AKY013/4 Chapter 2
Detailed information:BEY 007/8
= Preferred product range
146
Electronic signal encoders
VT 10468, VT 10406, VT 10399 signal encoders
• Manually operated command value encoders for valve and pumpcontrols using amplifier modules or cards
• Sensitive control due to low operating forces
• Integrated impedance convertor for load-independentcharacteristic curve linearisation
• Reverse voltage protection
• Replaceable bellows
• Options: – Deadman contact– Direction and zero point contacts– Spring-centering or locking in any position by means
of friction brake
Technical data
Operating voltage UB ± 15 VDC
Output signal ± 10 V; 5 mA
Switching contacts 30 VDC; max. 2 A
Operating force: – VT 10468 F Approx. 6 to approx. 10 N– VT 10406, VT 10399 F Approx. 7 to approx. 16 N
Permissible ambient temperature range ϑ – 25 to + 70 °C
Detailed informationto electronics:
RE 29 753
RE 30 754
RE 30 755
Type of electronics
VT 10468 1 control axis
VT 10406 2 control axes
VT 10399 3 control axes
= Preferred product range
147
Type
I/U2-U/I1 Input signal 0 to 20 mA or 4 to 20 mAOutput signal 0 to 10 V or 0 to ± 10 Vor reversed conversion
I/U-mA/V Module, input signal 0 to 20 mA or 4 to 20 mAOutput signal 0 to 10 V or 0 to ± 10 V
D/A2-BCD Input signal BCD (2-digit)Output signal 0 to ± 10 V (2 channels)
SIGN-ADAP Command value signal calibration for valves with integratedelectronics. inflection calibration; calibration for differentialcylinder. Input signal 0 to 20 mA; 4 to 20 mA; 0 to ± 10 V
Type
– Potentiometer with micro switch for 1 axisOutput signal 0 to ± 10 V
POTM-M 10 pitch potentiometer for 0 to +10 V or -10 to +10 V
POTM-CARD 2-channel command value call-up card; 4 x 0 to ± 10 V per channel
RAMP-POTM Command value and ramp card; 4 x 0 to ± 10 V;Ramp time 0.05 to 10 s
RAMP-LIN Command value and ramp card; 4 x 0 to ± 10 V;Ramp time 0.1 to 60 s
POTM-RAMP Command value and ramp module; 4 x 0 to ± 10 V;Ramp time max. 10 s
Command value technologySignal convertor
Command value technology• Modules and electronic circuit cards for
generating voltage command values and ramps
Signal convertor• Modules and electronic circuit cards for
converting current into voltage signals or digitalinto analogue signals
Detailed information:AKY013/4 Chapter 4
Detailed information:AKY013/4 Chapter 4
= Preferred product range
148
Racks and card holdersPower supply and stabilizing units
Racks and card holders
Type of electronics
VT 19101 Rack 1 x 3HE for cards 100 x 160 mmwith or without connector back panel
VT 19102 Rack 2 x 3HE for cards 100 x 160 mmwith or without connector back panel
VT 19103 Rack 3 x 3HE for cards 100 x 160 mmwith or without connector back panel
VT 19110 Bus rack 3HE for cards 100 x 160 mmor 100 x 220 mm
VT 10812 Connection adaptor with 32- or 48-pin socket connectorfor VT 19101 to VT 19103 without connector back panel
VT 3002 Open card holder with 32-, 48- or 64-pin socket connector
VT 12302 Closed card holder with 64-pin socket connector
Racks and card holders
• 19" rack for accommodating electronic assemblies in Euro-cardforamt
• Card holder for accommodating an electronic assembly in Euro-card format
• Separate power supply
Power supply and stabilizing units
• Smoothed or regulated output voltages
• Stabilization of smoothed voltages
Power supply and stabilizing units
Type of electronics
VT-NE1 Input voltage: 110/220 VACOutput voltage: + 24 to 38 VDC or
± 22 to 30 VDCPlug or terminal connection
VT-NE3 Voltages as with VT-NE1, but terminal connection only
VT-SE1 and VT-SE3 Stabilizing units for VT-NE1 and VT-NE3
VTS 0908 (NT 3) Input voltage: 110/220 VACOutput voltage: ± 15 VDC; 0.4 A and
± 24 VDC; 0.2 A and+ 5 VDC; 0.6 A
VTS 0909 (NT 4) Input voltage: + 24 VACOutput voltage: ± 15 VDC; 0.35 A and
+ 5 VDC; 1.0 A
VT-NE30 Input voltage: 115/230 VACOutput voltage: + 26 VDC/2.5 A
VT-NE31 Input voltage: 115/230 VACOutput voltage: ± 24 VDC/2 x 0.25 A
VT-NE 32 Input voltage: 115/230 VACOutput voltage: + 25 VDC/2.5 A and
+ 24 VDC/1 A (regulated)
Detailedinformation:
RE 29 768
RE 29 768
RE 29 768
RE 29 768
RE 30 105
RE 29 928
RE 30 103
RE 29 713
RE 29 712
RE 29 714
RE 29 772
On request
RE 29 929
RE 29 929
RE 29 929
= Preferred product range
149
Housings and card holdersPower supplies
Housings and card holders• Universal housing for 2 or 4 circuit cards
in Euro-card format DIN 41 612– external connections via screw terminals– Connection contact loading up to 4 A– Slots that are not required can be covered
with a blanking plate
• Card holders for circuit cards in Euro format(single and double)– External connections via screw terminals
Detailed information:AKY 013/4 Chapter 2
Detailed information:AKY 013/4 Chapter 3
Technical data
Card holders DIN 41 612-F32
Housings DIN 41 612
Technical data
Power supply, snap on PS02Input voltage 115/230 VACOutput voltage +24 VDC; 4 A
Power supply with card holderInput voltage 115/230 VACOutput voltage +24 VDC; 3 A
Housing with power supply and 2 slots PS01-CH20Input voltage 115/230 VACOutput voltage 2 x +24 VDC; 2,5 A
+24 VDC; 0,3 A stabilePower supply filter moduleInput voltage 24 VDCOutput voltage +24 VDC; 2,5 APower supply card with signal amplifier DC/DC-APCInput voltage +21 bis +40 VDCOutput voltage ±15V; 200 mA
±10V; 10 mA
Power supplies
• Power supply can be snapped on PS02
• Power supply with card holder
• Housing with power supply PS01-CH20
• Power supply filter module
• Power supply card with signal amplifier DC/DC-APC
= Preferred product range
150
Active plug
• Compact amplifier in a plug housing
• Controlled output stage
• In and outputs are short circuit proof
• Calibration via a trimming potentiometer
• Adjustment possiblities– Valve zero point– Sensetivity– Ramp times– Dither amplitude
• Protection– IP65 when fitted
Amplifier for proportional pressure relief valves type PV1/2-DBVand proportional pressure control valves type PV2-DRV
Detailed information:AKY013/1 Chapter 12
For proportional pressure control andpressure relief valves see page 104
Technical data
Connections Solenoid DIN 43 650UB com.value Cable 5 x 0.75mm2 screened
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Supply voltage Nom 24VDCSolenoid 2.5A Battery voltage 10.2 to 31V
Rectified voltage 10.2 to 27VSolenoid 0.8A Battery voltage 21 to 31V
Rectified voltage 21 to 27VResidual ripple < 2Vss
Ramp times 10ms to 5s
Dither amplitude range 80 to 350Hz, as an option
Electronic type Suitable for valve type
AS 0,8-V PV1/2-DBVWithout position control V-command valuePV2-DRV-3WWithout position control V-command valuePV2-DRVWithout position control V-command value
AS 0,8-mA PV1/2-DBVWithout position control mA-command valuePV2-DRV-3WWithout position control mA-command valuePV2-DRVWithout position control mA-command value
AS 2,5-V PV1/2-DBVWithout position control V-command value
AS 2,5-mA PV1/2-DBVWithout position control V-command value
= Preferred product range
151
Technical data
Connections Solenoid DIN 43 650UB com. value Cable 5 x 0.75mm2 screened
Ambient temperature range ϑ 0 to + 70 °CStorage temperature range ϑ – 20 to + 70 °C
Supply voltage nom 24VDCSolenoid 2,5A Battery voltage 10.2 to 31V
Rectified volage 10.2 to 27VSolenoid 0,8A Battery voltage 21 to 31V
Rectified volage 21 to 27VResidual ripple < 2Vss
Ramp times 10ms to 5s
Dither amplitude range 80 to 350Hz, as an option
Active plug
• Controlled output stage
• In and outputs are short circuit proof
• Calibration via a trimming potentiometer
• Adjustment possibilities– Valve zero point– Sensetivity– Ramp times– Dither amplitude
• Protection– IP65 when fitted
Amplifier for proportional throttle valvesand proportional flow control valves
Detailed information:AKY013/1 Chapter 12
For proportional throttle andflow control valves see page 110
Electronic type Suitable for valve type
AS 2,5-V QV1-4/2 WVWithout position control V-command valueQV-3W-SRVWithout position control V-command value
AS 2,5-mA QV1-4/2 WVWithout position control mA-command valueQV-3W-SRVWithout position control mA-command value
= Preferred product range
152
Technical data
GeneralValve connection DIN 43 650 Form AAmbient temperature range ϑ -20 to + 70 °CHousing Plastic, fire resistantAS-I busOperating voltage 26.5 to 31.6 VVoltage type Safety extra low voltage PELV (IEC64)Address Address socketPower componentOperating voltage UB 20 to 36 VDCThe external supply voltage must be protectively separated from the AS-I cable inaccordance with EN 60947-1OutputsOutput voltage Uout = UB - 1.5 V (typical)Valve connection Form A, DIN 43 650 (ISO 4400)Connections for further valves M12 socket, 5-pinInputsInput voltage From AS-I bus to IEC 1131-2Connection L1, L2 for external sensor M12 bus, 5-pin
Field bus capable active plugs for hydraulic switching valvesAS-I- field bus
Field bus capable active plugs
• Up to 2 actuators and sensors can be connected
• Small compact design
• Simple installation with low address requirements
• LED display for improved overview
• Integrated polarity reversal protection
• Simple diagnostics
• A separate 24V cable for the actuatorpower supply
• Max. cycle time < 5ms
• Protection IP67
Electronic type IN OUT L1 (M12) L2 (M12) O1 (Form A) O2 (M12)
A (2x I/0,2 A) + (2x O/2A) x x x x
B (2x O/2A) – – x x
C (1x O/2A) – – x –
Detailed information:BEY 006/19
= Preferred product range
153
Test and service unitsTypes VT-SVTSY-1 and VT-VETSY-1
Type VT-HNC100DEMO
Detailed information:RE 30 133
Controlled system simulator for the VT-HNC100-1-2Xdigital axis control
Type VT-VETSY-1
Detailed information:RE 29 685
Service case with test unit for servo valves withintegrated electronics
Type VT-SVTSY-1Detailed information:RE 29 681
Service case with test unit for servo valves withoutintegrated electronics
= Preferred product range
154
Test and service unitsfor proportional and high response valves
Test boxes
• Function testing and for commissioning of valvesand their associated electronics
• Command values can be internally or externally applied
• Measuring points for the in and outputs
• 115/230 V AC supply
• Connection cable is included within the scope of supply
Type
Test box I For all direct operated proportional valveswithout integrated electronics
Test box II For pilot operated proportional and high response valveswith external amplifiers
Test box III For valves with integrated electronics andvoltage interface
Measurement adaptors
• Checking the signal exchange betweenthe system control and the valve
• The presence of the supply voltageis indicated
Type
Measurement adaptor (7P) For all valves with 7-pin built-inelectronics (OBE) and voltage interface
Measurement adaptor (12P) For all valves with 12-pin built-inelectronics (OBE)
Current measurement adaptor For measuring the valve solenoid current
Test adaptor For Euro command cards, plugs to DIN 41 612-F32
Detailed information:AKY013/4 Chapter 10
Detailed information:AKY013/4 Chapter 10
= Preferred product range
155
Simulation technology
Technical calculations
Technical calculations, simulations and system analysis to customerspecifications
• Drive simulation
• Multi-body dynamics
• Simulation of complete systems
• Natural requency analysis
• Strength calculations
• 3D flow mechanics (CFD)
Detailed information:RE 09 372
HYVOS 6.0
Simulation software for valve controlled cylinder drives
• Non-linear simulation of a closed-loop electro-hydraulic drive
• Library of Bosch-Rexroth components
• Freely programmable components
• User friendly interface
Detailed information:RE 09 373
3D animation and multi-media presentations
Generation of 3D animations and presentations tocustomer specifications
• Virtual 3D animations
• Complete video productions
• Interactive multi-media presentations
• High resolution rendered pictures
Detailed information:RE 09 374
= Preferred product range
156
Notes
157
CONTROL BLOCKS / PLATES
Control blocks / plates,
are integrated hydraulic controls which arecombined with built-in or flanged onfunction elements.
The basis for this is the hydraulic circuitcomplete withdetails regarding the connection andoperating element locations.
The advantages of the block designwhen compared with individual pipework:
• Lower flow resistance / good efficiency
• Fewer sealing points
• Compact / high power density
• Branch specific solutions
• Cost reduction
158
Control blocksCompact hydraulics
Detailed information:On request
Standardised as well as as branch independentcontrol blocks• Manifold blocks
• Standard functions of sandwich plate design
• Pump control blocks
• Accumulator safety blocks
Detailed information:On request
Branch and customer specific control blocks(individually manufactured, small series)
• Press control blocks
• Modular control blocks for machine tools
• Control blocks for plastic's machines, foundry machines,power stations, etc.
Detailed information:RE 18 103
Compact hydraulics
Compact control blocks due to the tendency towards usingcartridge valves.
It concerns a manufacturing and cost optimised design, as well asstandardised and individual application specific designs.
The increased design costs are directly related to the seriesquantity.
= Preferred product range
159
The following sandwich plate valves can be found within this brochure whichare suitable for mounting onto the standard manifold blocks.Component functions Page
Pressure relief valves 58, 60
Pressure reducing valves 62, 64
Check valves 43, 46
Isolator valves 46
Double throttle check valves 69, 73
2-way flow control valves 72
Hydro-electric pressure switch for sandwich plate mounting 163
Multi-station manifold plates
• Compact hydraulic control due to common pressure and returnport for all control circuits
• Separate actuator ports for each control circuit
• Implementation of various control circuits possible using verticalstacking elements of sandwich plate design
Type HSR
Nominal sizes 6, 10, 16
Detailed information:• Nominal size 6
RE 48 107
• Nominal size 10RE 48 110
Nominal size 6 10 16
Operating pressure pmax bar 315 315 315
No. of ready-for-connection control circuits 10 8 6
Multi-station manifold platesType HSR
= Preferred product range
160
Notes
161
ACCESSORIES(measuring and monitoring components, filters)
Filters
This product segment encompasses highpressure, low pressure and return filters forline mounting and tank mounting as wellas a range of accessories.
The performance profile
• Maximum flow of 450 litres
• High pressure version up to 420 bar
• For fitting into return or pressure lines
• Exchangable cartridges
• Optical and electrical cloggingindicators
Measuring and monitoringcomponents
In addition to the filters we have furthercomponents available:
• Piston and bourden tube pressureswitches
• Pressure gauge isolator valves
• Pressure gauge selector valves
• Pressure gauge
• Float switch
• Thermostats
162
Pressure gauge isolator valves type AF and Multi-circuit gauge isolators, type MSBourdon tube pressure switches types HED 2 and HED 3
Pressure gauge isolator valve• 3-way straight valve• For subplate mounting ("P")• For threaded connection ("A")• Push-button operated• With or without accessories
(connection piece, 2 gaskets, pressure gauge, round anchor plate)• Various indicator ranges, optional:
up to 60, 100, 160, 250, 400 bar
Multi-circuit gauge isolator• Housing valve as in-pipe valve (connection types "A" and "F")• With flange mounting (connection types "B" and "E")• For subplate mounting ("C")• For threaded connection NPT ("G")• Fixing bores for UNC screws ("H")• With max. useful indicator range, optional:
up to 40, 63, 100, 180 or 315 bar• With 5, 6, 8 or 9 measuring points, optional• With integrated pressure gauge, optional• Leak-free isolation (type MSL2)
Type AF
Series 3X
Operating pressure pmax bar 300
Typ AFNominal size 6
Detailed information:RE 50 030
Type MS2, MSL2 MS4 to MS7
Connection type A, B, C, E, F, G, H A
Series 2X 2X
Operating pressure pmax bar 315 315
Type MSSeries 2, 4, 5, 6, 7
Detailed information:RE 50 034
Bourdon tube pressure switch with constant switchingpressure differential (type HED 2) and with infinitelyadjustable switching pressure differential (type HED 3)
• For threaded connection
• With check lamp, optional
• Various electrical connections
• With lockable rotary knob (type HED 2)
• With lockable cap, optional (type HED 3)
• Switching pressure differential can be adjusted by separate,independent adjustment of switching pressures (type HED 3)
• 5 pressure stages: 25, 63, 100, 200, 400 bar
Detailed information:• Type HED 2
RE 50 045
• Type HED 3RE 50 050
Type HED 2 HED 3
Series 2X 3X
Operating pressure pmax bar 400 400
Switching frequency Operations/min 30 30= Preferred product range
163
Piston type pressure switchesTypes HED 1, HED 5 and HED 8
Piston type pressure switch, type HED 1• For threaded connection• With leak-oil port, optional• With check lamp, optional• With explosion protection and intrinsically safe current circuit, optional• Pressure stages: – Version"K": up to 100, 350, 500 bar
– Version"O": up to 50, 100, 350 bar
Piston type pressure switch, type HED 5• For subplate mounting ("OP")• For in-line installation ("OA")• For female thread ("OK")• 4 pressure stages: 50, 210, 350, 630 bar
Piston type pressure switch, type HED 8• For subplate mounting ("OP")• For in-line installation ("OA")• As vertical stacking element in horizontal stacking assemblies ("OH")• With check lamp, optional (only with large plug-in connector)• With lockable rotary knob, optional• Pressure stages: – Versions "OP" and "OA": 50, 100, 200, 350, 630 bar
– Version "OH": max. 50, 100, 350 bar
Type HED 1
Version "K" "O"
Series 4X 4X
Operating pressure pmax bar 500 350
Switching frequency Operations/min 300 50 1)
Detailed information:• Type HED 1
RE 50 040
• Type HED 5RE 50 055
• Type HED 8RE 50 060
Type HED 5 HED 8
Series 2X 1X
Operating pressure pmax bar 630 630
Switching frequency Operations/min 80 801) Briefly 100
Pressure switch, mechanical
• Piston pressure switch without drain connection
• Adjustment elements– Grub screw with internal hexagon– Grub screw with internal hexagon and scale
Detailed information:AKY 007/3
– Lockable rotary knob with scale
• Indicator lamp, optional (integrated into the plug-in connector)
• Optional– Sandwich plate connection– Pipe connection– Flange connection
Nominal size 6
Operating pressure pmax bar 315/400
Switching frequency Switching/min 120
= Preferred product range
164
Pressure filter for fitting into pressure lines, type ABZFDReturn filter for direct tank mounting, type ABZFR
Type ABZFDDetailed information:RE 50 076
Nominal size 40 to 350
Operating pressure pmax bar 420
Flow qV max L/min 350
Pressure filter• Filter elements are based on inorganic fibres
• Absorbtion of the finest particals over a wide pressuredifferential range
• The large specific absorbtion area leads to a high contaminationretention capacity
• The filter elements have a high burst resistance (e.g. during coldstart)
• 10 µm filter rating absolute
Type ABZFR
Detailed information:RE 50 081
Return filter for direct tank mounting
• Filter element are based on a inorganic fibres
• Excellent separation (β values) over a wide pressure differentialrange
• High contamination retention capacity due to a large specificfilter surface area
• The filter elements have a high bust resistance (e.g. cold start)
• 10 µm filter rating absolute
Nominal size 50 to 450
Operating pressure pmax bar 25
Flow qV max L/min 350
= Preferred product range
165
ACCUMULATORS AND ACCUMULATOR ACCESSORIES
Accumulators
The main use of hydraulic accumulators isto minimise the pump drive power, forvolume compensation, to smooth outpressure peaks, as well as storing energyand as pulsation dampers.
The performance profile
• Bladder accumulators 1 to 50 litres
• Membrane accumulator 0.075 to 2.80 litres
• Safety and isolator blocks
• Charging and testing kits
• Mounting elements
• Safety elements
• Accumulator loading valves
166
Accumulator assemblies and safety blocksTypes ABSBG, ABZSS
Type ABSBG
Detailed information:RE 50 135
Technical data
Accumulator type Bladder type accumulator
DN Litres 1 to 50
Accumulator type Membrane type accumulator
DN Litres 0.6 to 2
Accumulator safety block DN 10 to 32• Operating pressure pmax bar 330
Accumulator assemblies• Accumulator assembly with safety block according to DIN 24 552
• Bladder or membrane type accumulators
• Safety block with integrated shut-off valve, safety valve (type-tested) and unloading valve
• Unloading valve either manually or electrically operated
• Glycerine-filled pressure gauge with red marking of the pressureto be adhered to
• Bracket suitable for welding into place
Type ABZSS
Nominal sizes 10 to 30
Detailed information:RE 50 131
Accumulator safety block
• Protection, isolation and unloading of hydraulic accumulators
• Meets the requirements and safety regulations according toDIN 24 552, pressure vessel regulations and technical rules forpressure vessels (TRB 403 or TRB 404)
• Accumulator adaptors available as accessories for connectingaccumulator safety blocks to the accumulators
Nominal size 10 20 30
Operating pressure pmax bar 350 350 350
Weight m kg 5.2 8.5 20.5
= Preferred product range
167
Hydro-pneumatic accumulatorsAccumulators safety and isolator blocks
Detailed information:AKY 014/1
Hydro-pneumatic accumulators
• Bladder or membrane accumulators
• Charging and testing kits
• Mounting elements
• Safety elements
• Certificates for design and pressure tests
Accumulator safety and isolator blocks
• Safety, isloation and unloading of hydraulic accumulators
• Complies with the requirements and safety regulations toDIN 24 552 pressure vessel regulations and the technicalregulations for pressure vessels (TRB 403 or TRB 404)
• Safety valves are design tested
• Electrical or manual unloading valve
Nominal size 20 32
Operating pressure pmax bar 350 350
Weight m kg 6 14.7
Technical data
Accumulator type Bladder accumulator
DN Litres 1 to 50
Accumulator type Membrane accumulator
DN Litres 0.075 to 2.8
Detailed information:AKY 014/1
= Preferred product range
168
Safety valvesAccumulator loading valves
Detailed information:AKY 014/1
Safety valves
• Design tested safety valves
• Protection of hydraulic accumulators
• Acceptance to the pressure vesselregulations and the technical rulesfor pressure vessels TRB 403
• Design tested by the TÜV authorities
Detailed information:AKY 014/1
Accumulator loading valve
• Switching off a fixed displacement pump
• 2 pressure settings
• NS6 subplate mounting
Technical data
Operating pressure pmax bar 360
Unloading flow L/min Up to 150
Nominal size 6
Operating pressure pmax bar 315
Flow qmax L/min 40
= Preferred product range
169
HYDRAULIC POWER UNITS AND ACCESSORIES
Hydraulic power units
Hydraulic power units are the basics of ahydraulic system.
Dimensioning and design are the determiningfactors for environment compatibility and for theefficiency of the entire system.
The performance profile
Standard small power units
• Oil reservoirs wtih contents of 20, 40or 60 litres
• Drive powers from 0.37 to 7.5 kW
• Can be extended by using combination systems
Standard power units• Oil reservoirs with contents from 100 to 630 litres
• Drive powers from 5.5 to 45 kW
Individual power units
• Are designed and manufactured to thecustomer's requirements
By the complimenting hydraulic power unitswith control blocks Bosch-Rexroth can supplythe entire system from a single source!
Filter cooler/circuitaltion circuit
• Compact circulation circuit withcirculation pump, built-on line filter and aplate type cooler
• Designed to a modular principle
Bell housing• With oil / air cooler
• Structure damped with regard tostructure-bourne noise and vibration, lownoise pressure level
170
Standard power unitsTypes ABSKG, ABSAS
Modular standard power units
• Stable aluminium reservoir
• Modular design
• Compact power unit design
• Individual matching possible
• Suitable for a variety of applications
• Additional options possible
• Clearly arranged, maintenance-friendly design
Type ABSKG
Reservoir capacity: 20; 40 and 60 litres
Reservoir version: Aluminium reservoir
Detailed information:RE 51 013
Technical data (pump/motor)
Pump type Radial piston (fixed displacement)
• Displacement Vg max cm3 1.6 to 10
• Operating pressure pmax bar Up to 315
Pump type Gear (fixed displacement)
• Displacement Vg max cm3 1.9 to 16
• Operating pressure pmax bar Up to 250
Electric motor power P kW 0.37 to 7.5
Type ABSAS
Reservoir capacity: 100; 160; 250; 400 and630 litres
Reservoir version: Steel reservoir toDIN 24 339, form ANcover form C, standard sheet AB-E 40-40
Detailed information:RE 51 101
Technical data (pump/motor)
Pump type Axial piston (variable displacement)
• Displacement Vg max cm3 18 to 100
• Operating pressure pmax bar Up to 315
Electric motor power P kW 5.5 to 45
Standard power unit
• Stable steel reservoir
• Modular design of controls, reservoirs, accumulator assemblies,cooler assemblies
• Motor/pump group
• Filter/cooling circulation circuit
• Basic power unit comprising pump power unit, reservoiraccessories (filler/breather, oil level indicator, inspection cover,drain valve), return line filter, float switch, thermostat
= Preferred product range
171
Standard power units type ABHSGHydraulic reservoirs type ABTSR
Standard power unit
• Stable steel reservoir
• Thanks to the modular principle, the units can be easily extended
• Good accessibility to all components
• Suitable for a variety of industrial applications
• Long service life
• Low noise emission
• Flow matched to the control and adjustment elements
Type ABHSG
Reservoir capacity: 400; 630; 800 and1000 litres
Reservoir version: Steel reservoir withsupports
Filter: Filter/cooling circulation circuit
Detailed information:RE 51 027
Technical data (pump/motor)
Pump type Axial piston (variable displacement)
• Displacement Vg max cm3 45 to 250
• Operating pressure pmax bar Up to 315
Electric motor power P kW 7.5 to 160
Type ABTSRReservoir capacity: 1000 to 20 000 litres
Detailed information:RE 51 135
Hydraulic reservoir
• Steel reservoir with high static and dynamic stiffness
• Pipe joints through the reservoir wall with welding fittings,SAE or DIN flanges
• Suction chamber separated from return chamber
• Reservoirs are available with dividing wall or baffles
• Lifting lugs for transport purposes
• Steps in reservoirs for reservoir sizes 5000 to13 000
• Ladders in reservoirs for reservoir sizes 16 000 to20 000
= Preferred product range
172
Standard power unitsTypes ABPAG, ABFAG
Type ABPAG
Reservoir capacity: 63 to 400 litres
Detailed information:RE 51 018
Type ABFAG
Reservoir capacity: 100 to 630 litres
Detailed information:On request
Technical data (pump/motor)
Pump type Axial piston (variable displacement)
• Displacement Vg max cm3 28 to 250
• Operating pressure pmax bar Up to 360
Electric motor power P kW 15 to 160
Technical data (pump/motor)
Pump type Axial piston (variable displacement)
• Displacement Vg max cm3 28 to 140
• Operating pressure pmax bar Up to 315
Electric motor power P kW 7.5 to 75
Hydraulic drive power unit
• Very low operating noise
• For numerous applications:– General machinery– Injection moulding machines– Lifting equipment– Presses– Laboratories, schools
• Flow matched to the control and adjustment elements used
Hydraulic primary power unit
• For closed circuits
• Stable steel reservoir
• Good accessibility
• Suitable for a wide variety of industrial applications:– Shredder systems– Stirring drives– Mixers– Centrifuges– Winders
• Flow matched to the control and adjustment elements used
= Preferred product range
173
Standard power units
Detailed information:BEY 004/2
Small power units
• Stable aluminium reservoir
• Modular design
• Can be extended by using combination systems
• Numerous application possiblities
• Reservoir volumes of 10, 25 and 50 litres
Detailed information:On request
Project power units• Stable steel reservoir
• Modular mounting of controls, accumulator modules,cooler modules
• Motor pump assembly
• Reservoir volume up to 1250 litres
Technical data (pump/motor)
Pump type Gear pumps (fixed)
Displacement volume Vg max cm3 1 to 16
Operating pressure pmax bar Up to 200
Electric motor power P kW 0.37 to 7.5
Technical data (pump/motor)
Pump type Fixed and variable pumps
Displacement volume Vg max cm3 1 to 140
Operating pressure pmax bar Up to 315
= Preferred product range
174
Clamping and drive modulesTypes UPE2, UPE3
Type UPE2
Reservoir capacity: 2.4 to 7.2 litres
Reservoir version: Aluminium reservoir withintegrated motor
Detailed information:RE 51 142RE 51 144
Technical data (pump/motor)
Pump type Radial piston pump (fixed displacement)
• Displacement Vg max cm3 0.40 to 2.0
• Operating pressure pmax bar Up to 700
Pump type Gear pump (fixed displacement)
• Displacement Vg max cm3 1.0 to 10.0
• Operating pressure pmax bar Up to 260
Electric motor power P kW 1.1 to 2.2
Clamping and drive modules
• ON time, S2 short time operation and S3 intermittent operation
• Compact design
• Low noise
• For a variety of applications
• Large number of variants
• Complete hydraulic control possible
• No piping of the control required
• External attachment possible
• Ready for installation
Type UPE3
Reservoir capacity: 8.6 to 10.5 litres
Reservoir version: Aluminium reservoir withintegrated motor
Detailed information:RE 51 147RE 51 144
Technical data (pump/motor)
Pump type Radial piston pump (fixed displacement)
• Displacement Vg max cm3 0.67 to 1.67
• Operating pressure pmax bar Up to 700
Pump type Gear pump (fixed displacement)
• Displacement Vg max cm3 1.0 to 10.0
• Operating pressure pmax bar UP to 260
Electric motor power P kW 3.0 to 4.0
Clamping and drive module
• ON time, continuous S1
• Compact design
• Low noise
• High cooling power
• Single and double pump
• Two separate hydraulic controls possible
• No piping of the control required
• Ready for installation
= Preferred product range
175
Clamping and drive modules type UPE5Filter/cooling circulation circuit type ABUKG
Type UPE5Reservoir capacity: 26 litres
Reservoir versions: Aluminium reservoir
Detailed information:RE 51 145RE 51 149
Technical data (pump/motor)
Pump type External gear pump (fixed displacement)
• Displacement Vg max cm3 6.0 to 16.0
• Operating pressure pmax bar Up to 200
Pump type Internal gear pump (fixed displacement)
• Displacement Vg max cm3 4.0 to 16.0
• Operating pressure pmax bar Up to 250
Pump type Vane pump (varible displacement)
• Displacement Vg max cm3 10 to 20
• Operating pressure pmax bar Up to 160
Electric motor power P kW 1.5 to 4.0
Drive motor
• 100% duty cycle
• Compact design
• Low noise
• High cooling power
• For a variety of applications
• Various mounting options
• Complete hydraulic control possible
• Ready for connection
Type ABUKGCirculation pump: Types PGF2 or PVV
Electric motor BS 80 to 112
Line filter type LF
Plate heat exchanger
Detailed information:RE 50 120
Technical data
Pump type Internal gear (fixed displacement); vane pump (fixed displacement)
Heat dissipation capacity P kW 4 to 37
Filter/cooling circulation circuit
• Compact circulation circuit with circulation pump, built-on linefilter and plate heat exchanger
• Design according to the modular principle
= Preferred product range
176
Bell housing with oil/air cooler
• Nominal pressure 8 bar
• Structure damped with regard to structure-bourne noise andvibration, low noise pressure level
• High cooling capacity with low space requirement
• Suitable as main flow cooler
• Short, compact build, simple installation and removal of the heatexchanger
Type PTK
Nominal sizes for electric motor 80 to 180
Detailed information:RE 50 092
Nominal size 2001 200 250 300 350 3501
Air throughput m3/h 90 90 210 360 850 850
Operating pressure pmax bar Up to 8
Power P kW 0.55-0.75 1.1-1.5 2.2-4 5.5-7.5 11/15 18.5/22
Speed 1) nmax min-1 1500
Weight m kg 4 4 6 9 13 13 1) Other speeds on request
Bell housing type PTK
= Preferred product range
Bosch Rexroth AGD-97813 Lohr a. Main
Zum Eisengießer 1 • D-97816 Lohr a. Main
Telephone 0 93 52/18-0Telefax 0 93 52/18-23 58Telex 6 89 418-0
eMail documentation@rexroth.deInternet www.boschrexroth.de
RE 00 208/11.01 Replaces: 04.01
Recommended