LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
ASD LED Edge lit Flat Panels are modern, cutting edge fixtures producing 110 lm/w. This Edge lit panel measures only 1/2 “ thick making
it one of the slimmest panels in the marketplace today. Our UL and DLC Standard rated panel is high efficiency, absent of hazardous
materials and maintenance-free. Hybrid emergency system with integrated signal indicator provides 90-minute emergency operation with no additional wiring required, installation is fast and simple.
Our LED panels are an ideal choice to reduce energy costs in commercial and residential applications. They are most commonly used in offices, schools, hospitals, retail stores and airports.
ASD LED Edge lit flat panels have low energy consumption, long life and a nice even light virtually eliminating glare and shadows.
▶ 90+ minutes of emergency operation
▶ 35% emergency light level output
▶ < 24 hours battery charging time
▶ Low energy consumption
▶ Luminous efficiency 110-up lm/W
▶ White frame
▶ Available in 2x2 and 2x4 sizes
▶ Standard 0~10 V dimming
▶ L-70 Life > 81, 000 hrs
▶ DesignLights Consortium (DLC) listed (Classification: Standard)
▶ UL certified
▶ 5-year limited warranty
FEATURES AND BENEFITS:
ORDERING MATRIX:Family Modification Size Dimmable 0~10 V Watts CCT Series
ASD-ELP 12 XX D XX XX SHEEdge-Lit Panel 22 = type 2x2 Dimmable 27 = 27 W 3,500 K Standard
24 = type 2x4 40 = 40 W 4,000 K Hybrid Emergency5,000 K
LED EDGE-LIT PANEL STANDARD HYBRID EMERGENCY:
Model Type Watts Dimming
Compatible CCTLumens Dimensions
(LxWxH)Normal Emergency Normal Emerg. (calc)ASD-ELP12-22D2735-SHE 2х2 27 W 10 W yes 3,500 K 3,026 lm 1,120 lm 23.7" х 23.7" х 0.4"ASD-ELP12-22D2740-SHE 2х2 27 W 10 W yes 4,000 K 3,085 lm 1,143 lm 23.7" х 23.7" х 0.4"ASD-ELP12-22D2750-SHE 2х2 27 W 10 W yes 5,000 K 3,139 lm 1,163 lm 23.7" х 23.7" х 0.4"ASD-ELP12-24D4035-SHE 2х4 40 W 17 W yes 3,500 K 4,553 lm 1,935 lm 47.75" x 23.7" x 0.4"ASD-ELP12-24D4040-SHE 2х4 40 W 17 W yes 4,000 K 4,671 lm 1,985 lm 47.75" x 23.7" x 0.4"ASD-ELP12-24D4050-SHE 2х4 40 W 17 W yes 5,000 K 4,779 lm 2,031 lm 47.75" x 23.7" x 0.4"
HIGH LUMINOUS EFFICIENCY
110
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
PRODUCT SPECIFICATIONS:Construction & MaterialsHousing AluminumLens Translucent whiteFinish WhiteWeight ASD-ELP12-22D2735-SHE 8.95 lbs (4.07 kg) ASD-ELP12-24D4035-SHE 16.21 lbs (7.37 kg)
ASD-ELP12-22D2740-SHE ASD-ELP12-24D4040-SHEASD-ELP12-22D2750-SHE ASD-ELP12-24D4050-SHE
Optical SystemLuminous Flux ASD-ELP12-22D2735-SHE 3,026 lm ASD-ELP12-24D4035-SHE 4,553 lm
ASD-ELP12-22D2740-SHE 3,085 lm ASD-ELP12-24D4040-SHE 4,671 lmASD-ELP12-22D2750-SHE 3,139 lm ASD-ELP12-24D4050-SHE 4,779 lm
Color Temperature 3,500 K, 4,000 K, 5,000 KCRI 80
Emergency systemBattery charging time < 24 hoursEmergency operation time ≥ 90 minutesEmergency watts ASD-ELP12-22D2735-SHE
10 WASD-ELP12-24D4035-SHE
17 WASD-ELP12-22D2740-SHE ASD-ELP12-24D4040-SHEASD-ELP12-22D2750-SHE ASD-ELP12-24D4050-SHE
Emergency Luminous Flux ASD-ELP12-22D2735-SHE 1,120 lm ASD-ELP12-24D4035-SHE 1,935 lmASD-ELP12-22D2740-SHE 1,143 lm ASD-ELP12-24D4040-SHE 1,985 lmASD-ELP12-22D2750-SHE 1,163 lm ASD-ELP12-24D4050-SHE 2,031 lm
Environmental SystemWork Environment Indoor useOperating Temperature 14℉ to 104℉ (-10℃ to +40℃)Humidity 20% - 85% RH, non condensingL70 Life > 81, 000 hrs
Electrical SystemInput Voltage 100~277VAC 50/60 HzMax input current ASD-ELP12-22D2735-SHE 0.4 A ASD-ELP12-24D4035-SHE 0.6 A
ASD-ELP12-22D2740-SHE ASD-ELP12-24D4040-SHEASD-ELP12-22D2750-SHE ASD-ELP12-24D4050-SHE
Inrush current 50 AAction time (Inrush current) 0.5sAC input range min 100 V max 305 VOff State Power 0 WPower Consumption ASD-ELP12-22D2735-SHE 27 W ASD-ELP12-24D4035-SHE 40 W
ASD-ELP12-22D2740-SHE ASD-ELP12-24D4040-SHEASD-ELP12-22D2750-SHE ASD-ELP12-24D4050-SHE
Power Factor ≥ 0.99 Output voltage ASD-ELP12-22D2735-SHE 30-40 V ASD-ELP12-24D4035-SHE 30-40 V
ASD-ELP12-22D2740-SHE ASD-ELP12-24D4040-SHEASD-ELP12-22D2750-SHE ASD-ELP12-24D4050-SHE
Max output current ASD-ELP12-22D2735-SHE 700 mA ASD-ELP12-24D4035-SHE 1,050 mAASD-ELP12-22D2740-SHE ASD-ELP12-24D4040-SHEASD-ELP12-22D2750-SHE ASD-ELP12-24D4050-SHE
LED driver class P, class 2
Regular and Voluntary Certifications5-year limited warrantyDesignLights Consortium (DLC) listed (Classification: Standard)UL certified E473854 - Recessed mounted panel
ControlDimming Switch Standard 0~10 V dimming 5% - 100%Linking Qty 20 panels
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
TYPE 2x2 27W
4,000K 5,000K
23.7"
(603
mm
)
23.7" (603 mm) 1.2" (30 mm)
0.4" (10 mm)
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,114.8
UNIT:cd
C30/210,114.2
UNIT:cd
C60/240,114.1
UNIT:cd
C90/270,114.3
AVERAGE BEAM ANGLE(50%):114.4 DEG
0
190
380
570
760
950
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 16.5 33.0
S(m)5.60
4.70
3.70
2.80
1.90
0.9400
0.7500
0.4700
0.3700
0.2800
3,500K LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30UNIT:cd
C0/180,114.9UNIT:cd
C30/210,114.4
UNIT:cd
C60/240,114.4
UNIT:cd
C90/270,114.6
AVERAGE BEAM ANGLE(50%):114.6 DEG
0
200
400
600
800
1000
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 16.5 33.0
S(m)5.90
4.90
3.90
2.90
2.00
0.9800
0.7800
0.4900
0.3900
0.2900
3,500KLUMINOUS INTENSITY DISTRIBUTION DIAGRAM
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30UNIT:cd
C0/180,113.9UNIT:cd
C30/210,113.3
UNIT:cd
C60/240,113.5
UNIT:cd
C90/270,113.7
AVERAGE BEAM ANGLE(50%):113.6 DEG
0
400
800
1200
1600
2000
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 16.5 33.0
S(m)9.10
7.60
6.10
4.60
3.00
1.50
1.20
0.7600
0.6100
0.4600
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30UNIT:cd
C0/180,114.9UNIT:cd
C30/210,114.4
UNIT:cd
C60/240,114.3
UNIT:cd
C90/270,114.5
AVERAGE BEAM ANGLE(50%):114.5 DEG
0
200
400
600
800
1000
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 16.5 33.0
S(m)5.80
4.90
3.90
2.90
1.90
0.9700
0.7800
0.4900
0.3900
0.2900
TYPE 2x4 40W
4,000K 5,000KLUMINOUS INTENSITY DISTRIBUTION DIAGRAM
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,113.9
UNIT:cd
C30/210,113.4
UNIT:cd
C60/240,113.6
UNIT:cd
C90/270,113.9
AVERAGE BEAM ANGLE(50%):113.7 DEG
0
400
800
1200
1600
2000
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 16.5 33.0
S(m)9.30
7.70
6.20
4.60
3.10
1.50
1.20
0.7700
0.6200
0.4600
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30UNIT:cd
C0/180,113.9UNIT:cd
C30/210,113.2
UNIT:cd
C60/240,113.3
UNIT:cd
C90/270,113.5
AVERAGE BEAM ANGLE(50%):113.5 DEG
0
400
800
1200
1600
2000
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 16.5 33.0
S(m)9.30
7.70
6.20
4.60
3.10
1.50
1.20
0.7700
0.6200
0.4600
23.7"
(603
mm
)
47.8" (1213 mm) 1.2" (30 mm)
0.4" (10 mm)
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
WARNINGRISK OF PERSONAL INJURY – READ and follow all WARNINGS and installation instructions. Keep or give to the owner for future reference.
Risk of cuts: Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing, and maintaining this product.
Risk of electric shock: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Risk of Fire: Minimum 90°С supply conductors. Consult a qualified electrician to ensure correct branch circuit conductor.
ASD® assumes no responsibility for claims arising out of improper or careless Installation or handling of this product.
For recessed installation: Access above ceiling required. Inherently protected. Vapor barrier must be suitable for 90°C.
ELECTRICAL SCHEMATIC DIAGRAM
Connect the battery plug before wiring
X PANELS
X PANELS
L N GroundDim- Dim + SWL L N GroundDim- Dim + SWL L N GroundDim- Dim + SWL
LED DRIVER LED DRIVER LED DRIVER
L (live/hot) connect black
N (neutral) connect white
G (ground) connect green
Pow
er c
onne
ctor
120~
277V
50/
60 H
z
Dim + (Violet)
Dim - (Gray)
Description Q-tyLED Edge-Lit Flat Panel 2
Box 1
Installation Instructions 1
PACKAGE CONTENTS:
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
EMERGENCY SYSTEM DETAILS
BATTERY BACK-UP INFORMATION
SIGNAL INDICATOR
Battery capacity
Max emergency output power
Emergency current
Emergency operation time
Battery voltage
Full charge/discharge cycles
2,000mA * 4 10 W 300 mA ≥ 90 minutes 14.4 V 300 cycles
2,000mA * 6 17 W 500 mA ≥ 90 minutes 10.8 V 300 cycles
Malfunction Emergency
Charging
Main Power TEST
Malfunction Emergency
Charging
Main Power TEST
Red LED: Charged
1. When red LED flashes and green LED is lit, the battery is on charge.
2. When the battery gets fully charged, red LED goes off and green LED lights up.
Green LED: Main Power Yellow LED: Malfunction
Standard operation display status
Warning display status
Operating Condition Main Power Charged Malfunction Light
Light ON ON Slow Flashing/OFF OFF ONEmergency work OFF ON OFF ON
Light OFF ON / Slow Pulsing Slow Flashing/OFF OFF OFF
Operating Condition Main Power Charged Malfunction Light
No AC and Battery is out OFF OFF OFF OFF
No AC and Battery is low OFF Fast Blinking OFF ON
Battery is not Connected - - Fast Blinking -
Fault Current - - ON OFF
WARNING ▶ This product should be installed by a qualified electrician. Connecting wires when power is on is not allowed. Power can be
turned on after making sure that there is no phenomenon of short circuit and the connection is ok.
▶ The wall switch only controls the main power, does not affect emergency lighting.
▶ Green light - main power, Red light - charging, Yellow light – malfunction. Test - test button
▶ Frequent tests are prohibited. Interval between tests should be not less than one minute.
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
INSTALLATION GUIDEIMPORTANT SAFETY INFORMATION:Please read all the instructions below before installation.
▶ Make sure that the supply voltage corresponds to the rated product voltage.
▶ The product is designed for indoor use only.
RECESSED MOUNT1. Choose the ceiling panel where you want to install the
product, and remove it. For convenience, move adjacent ceiling tiles.
2. Fix the LED Panel into the ceiling: raise up the product above the bar, then place it on T-bars.
3. Secure the panel with the grid as shown in the picture. Connect wires as shown in electrical schematic diagram above.
4. Return the adjacent ceiling tiles to their places.
5. Turn on the main power. Installation is finished.
Two bend points for all four tabs
Ensure the tab is securely attached to the grid
15/16" Slot T 15/16" Tegular
Compatible with grid size
SURFACE MOUNT
Wall/ceiling mount:1. Put the pieces of frame to any horizontal surface.
Connect these 3 pieces of the frame to the ceiling using four screws.
2. Connect the panel wires as shown in electrical schematic diagram. Attach the fourth piece and secure with screws.
3. Turn on the main power. Installation is complete.
Connect three pieces together with screws (included)
Insert the panel into the frame formed by three connected pieces
Accessories for surface mount are sold separately.
FRAME FOR SURFACE MOUNTING ORDERING INFORMATION:
GTIN 12 Model Number Panel Size
859961005322 ASD-FELP22 2x2
859961005339 ASD-FELP24 2x4
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
RECESSED SHEETROCK MOUNT
A
B
C
C
B
A
A - End/intermediate RailB - Corner AngleC - Side Rail
Corner angleon inside of end
and side rails
Steelwire
1. Following the picture above, slide part B into the inboard side of parts C and A as shown.
2. Place assembled frame into a ceiling opening and add steel wires for support as pictured below.
Note: ▶ For best results, attach supporting steel wires going into
the ceiling to sides of frame after assembly
▶ End rail can be used as intermediate rail for tandem row
After wiring fixture, carefully slide it through ceiling opening, rotate and drop fixture into place.
Accessories for recessed sheetrock mount are sold separately.
FRAME FOR RECESSED SHEETROCK MOUNTING ORDERING INFORMATION:GTIN 12 Model Number Panel Size855029006393 ASD-FDW-ELP22 2x2
857622006107 ASD-FDW-ELP24 2x4
SUSPENDED MOUNT(only for 2x2 and 1x4 LED Edge-Lit flat panels):
1. Make sure that the ceiling can hold the weight of the LED panel and install ceiling brackets suitable to support the weight of the LED panel. Affix cables.
2. Connect the wires as shown in electrical schematic diagram.
3. Attach the suspended cables to the bends at the edges of the LED flat panel.
4. Turn on the main power. Installation is finished.
Accessories Set
х 12
х 12
х 4
х 4
х 4
Accessories for suspended mount are sold separately.
CEILING HANGING SET ORDERING INFORMATION:GTIN 12 Model Number Suspended cables lenghs859961005148 ASD-CHS4 4 ft (1220 mm)
855029006522 ASD-CHS6 6 ft (1830 mm)
LED Edge-Lit Flat Panels
Hybrid Emergency Standard
E-mail: orders@asd-lighting.com Phone: 781-739-3977WebSite: www.asd-lighting.com Fax: 339-502-8970
LED EDGE-LIT PANEL STANDARD HYBRID EMERGENCY
Model Type Watts CCT UPC GTIN 14 Product Code
Pcs in one Carton
Carton Size Carton Weight
ASD-ELP12-22D2735-SHE 2х2 27 W 3,500 K 819201021093 10819201021090 021.0164 2 24.6"x24.6"x2.76" 19.36 lbsASD-ELP12-22D2740-SHE 2х2 27 W 4,000 K 819201021109 10819201021106 021.0165 2 24.6"x24.6"x2.76" 19.36 lbsASD-ELP12-22D2750-SHE 2х2 27 W 5,000 K 819201021116 10819201021113 021.0166 2 24.6"x24.6"x2.76" 19.36 lbsASD-ELP12-24D4035-SHE 2х4 40 W 3,500 K 819201021123 10819201021120 021.0167 2 48.6"x24.6"x2.76" 36.3 lbsASD-ELP12-24D4040-SHE 2х4 40 W 4,000 K 819201021130 10819201021137 021.0168 2 48.6"x24.6"x2.76" 36.3 lbsASD-ELP12-24D4050-SHE 2х4 40 W 5,000 K 819201021147 10819201021144 021.0169 2 48.6"x24.6"x2.76" 36.3 lbs
ORDERING INFORMATION
Recommended