CHECKLIST
SUSTAINABLE SITES
Prerequisite 1: Construction Activity Pollution Prevention
This prerequisite is intended to limit the amount of erosion, dust andwater sedimentation created by construction activities.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 4/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Prerequisite 1: Construction Activity Pollution Prevention
During construction, there can be a lot of pollution going on,
especially when it rains. Pollution on construction sites can be
reduced by controlling:
Soil Erosion Airborne Dust Generation
Waterway Sedimentation
Implementation
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 5/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Prerequisite 1: Construction Activity Pollution Prevention
Provide ESC (Erosion and Sedimentation Control) plan withconstruction documents and specifications.
Goal is to prevent the loss of soil, pollution, and
sedimentation.
Follow the EPA 2003 (Environmental Protection Agency)standards.
CGP (Construction General Permit) outlines how to
comply with NPDES program. CGP covers sites greater
than 1 acre, but LEED covers all.
For more info: http://cfpub.epa.gov/npdes/stormwater/cgp.cfm
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 6/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Prerequisite 1: Construction Activity Pollution Prevention
Ways to control sedimentation:
Stabilization: i.e. seeding and mulching
Structural: i.e. silt fences, earth dikes, sediment traps
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 7/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 1: Site Selection (1pt)
Intent: Develop sites that are already previously developed. Avoid developinginappropriate sites.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 8/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 1: Site Selection (1pt)
Forbidden Sites:
Below 5ft. above the 100 year flood elevation as defined by FEMA
Within 100ft. of Wetlands as defined by CFR (Code of Federal
Regulations)
Prime farmland as defined by USDA
Within 50ft. of a water body (lakes, seas, rivers, etc.) Comply with
Clean Water Act.
Habitat for any endangered or critical species.
Public parkland (Park Authority projects are exempt)
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 9/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 1: Site Selection (1pt)
Forbidden Sites:
Anything less than 5ft. above the 100 year flood elevation as
defined by FEMA
What this means: A site plan must be submitted that shows that you are at
least 5¶ above the 100 year flood line if either of those lines cross the site. If
neither line crosses the site, indicate the nearest USGS elevation contour
line.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 10/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 2: Development Density & Community Connectivity (5pts)
The intent of this credit is to develop in areas that have existinginfrastructure, and preserve natural habitat.
Option 1: Previously developed site in a community with a density of
60,000sf per acre net.
Option 2: Previously developed site within 1/2 mile of a residential zone with
10 units per acre and 1/2 mile from basic services.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 11/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 3: Brownfield Redevelopment (1pt)
Rehabilitate existing damaged/contaminated sites.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 12/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 4.1: Alternative Transportation: Public Transportation
Access (6pts)Reduce automobile use to help reduce pollution.
Locate the project
within 1/2 mile of some
sort of light rail system
or 1/4 mile away from
one or more bus stops
that are for 2 or more
bus lines.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 13/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 4.2: Alternative Transportation: Bicycle Storage &
Changing Rooms (1pt)Reduce the pollution caused by automobile use.
Bike Racks - within 200 yards of entrance
Bike Racks - for 5% of all building users
Showers - for 0.5% of all FTE occupants
Residential - bike racks for 15% of occupants
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 14/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 4.3: Alternative Transportation: Low Emission & Fuel
Efficient Vehicles (3pts)
The intent of this credit is to reduce the environmental impact caused by
automobile use.
Option 1: Provide low emitting or fuel efficient vehicles for 3% of
FTE occupants & preferred parking
Option 2: Preferred parking for low-emitting vehicles for 5% of
parking capacity
Option 3: Alternate fuel refueling stations for 3% of parking
capacity
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 15/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 4.3: Alternative Transportation: Parking Capacity (2pts)
Reduce the environmental impact caused by vehicle use
Option 1: Parking size not to exceed minimum needed & 5% for
car/vanpools (non-residential)
Option 2: Projects that have parking for < 5% & for car/vanpools
(non-residential)
Option 3: No more than minimum needed & carpooling
(residential)
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 16/27
LEED NEW CONSTRUCTION
CHECKLIST
SUSTAINABLE SITES
Credit 5.1: Site Development: Protect or Restore Habitat (1pt)
Promote biodiversity by conserving existing natural areas and or restoring damaged areas.
These practices involve
protecting greenfield sites,
restoring previouslydeveloped sites including
the possible use of a
vegetated roof.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 18/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Chart from: www.leeduser.com/credit/NC-2009
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 19/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 6.1: Storm Water Design: Quantity Control (1pt)
The intent of this credit is to limit the disruption of the natural hydrology.
CASE 1: Existing imperviousness less than or equal to 50%
CASE 2: Existing imperviousness that is greater than 50%
* To earn this credit with previously undeveloped sites, you¶ll need to avoid any
increase in runoff, while on mostly impervious developed sites, you¶ll need to
reduce runoff.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 20/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Chart from: www.leeduser.com/credit/NC-2009
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 21/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 6.2: Storm Water Design: Quality Control (1pt)
Reduce or eliminate water pollution by reducing the amount of impervious cover on a site.
In order to get awarded a point for this credit, there must be a stormwater
managament plan that reduces impervious cover and treats the stormwater runoff
from 90% of the average annual rainfall using acceptable best managementpractices (BPMs).
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 22/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 6.2: Storm Water Design: Quality Control (1pt)
Reduce or eliminate water pollution by reducing the amount of impervious cover on a site.
Possible Strategies:
Green Roofs
Pervious PavementRain Gardens
Vegetated Swales
Rainwater Recycling
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 23/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 7.1: Heat Island Effect: Non-Roof (1pt)
Reduce the Heat Island Effect for developed areas.
Option 1:
Non-Roof Hardscape Surfaces
50% of roads, sidewalks,courtyards, or parking lots are:
Light colored with high Solar
Reflectance Index (SRI > 29)
Open grid paving
Shaded by trees
Shaded by structures (with
SRI > 29)
Shaded by solar panels
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 24/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 7.1: Heat Island Effect: Non-Roof (1pt)
Reduce the Heat Island Effect for developed areas.
Option 2:
On-Site Parking
50% of on-site parking spots are under cover.
Parking areas are in a garage or underground
Parking area roof must have an SRI < 29 or
covered by solar panels or vegetation
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 25/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 7.2: Heat Island Effect: Roof (1pt)
Reduce the effect of heat islands in developed areas to minimize impacton microclimate and wildlife habitat.
Option 1: 75% Roofing Materials with SRI 29 - 78 (depending on slope)
Option 2: Use vegetated roof for at least 50%
Option 3: Combination of the Options 1 & 2
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 26/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 8.1: Light Pollution Reduction (1pt)
Minimize light pollution from interior and exterior building lighting systems.
EXTERIOR LIGHTING
Power densities can¶t exceed ASHRAE 90.1-2004 requirements for the
project zone per IESNA RP-33.
Meet light trespass limits at site boundary for the project zone.
Conduct light trespass analysis for all site lighting.
8/6/2019 LEED GA Sustainable Sites
http://slidepdf.com/reader/full/leed-ga-sustainable-sites 27/27
LEED NEW CONSTRUCTION
CHECKLISTSUSTAINABLE SITES
Credit 8.1: Light Pollution Reduction (1pt)
Minimize light pollution from interior and exterior building lighting systems.
INTERIOR LIGHTING
OPTION 1: Angle of maximum candela.
OPTION 2: Non-business hours
Recommended